VOLUME_2-_3_of_4.pdf

PDF 15 MB Posted

Attached to
MISSION TRAINING CENTER (MTC) SIMULATION CENTER AT FORT HOOD, TEXAS
Solicitation number
W9126G-17-R-0008
Issued by

About this file

RFP Drawing VOL 2 (3 of 4)

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT

OFFICES

CONFERENCE

MAIN

CONFERENCE

BREAK

ROOM

143A

TOILET

TR ROOM

OFFICE

OFFICE

CORRIDOR

EP406

A3

G

F

E

D

C

B

A.8

A.4

13 14

A

15 16 17 18

M A

T C

H

LI

N E

M A

T C

H

LI

N E

P

PP

SRLB-13

SRLB-15

SRLB-17

SRLB-19

SRLA-23

SRLA-19 SRLA-21

SRLA-27

SRLA-29

SRLB-20

GFI

CONFERENCE

GFI

GFI GFI GFI GFI GFI

NIPR CAFE

SRLB-4

SRLB-6

SRLB-8

SRLB-10

SRLB-12

SRLB-14

SRLB-2

CORRIDOR

T TT

T

T

TT

SS-10

FROM CU-10

ON ROOFIWH-1

SDH-38

SDH-42

IWH-2

7 VAV-12-14

7 VAV-12-15

7 VAV-12-13

7 VAV-12-05

7 VAV-12-04

7 VAV-12-03

7 VAV-12-18

7 VAV-12-02

7 VAV-12-01

T

T

TT

T

T

T

T

T

T

SRLB-9

SRLA-25

SRLA-17

SRLA-9

SRLC-2,4,6

SF

SRLC-8,10,12

SF

SRLC-14,16,18

SF

SRLD-1,3,5

SF

SF

SRLD-7,9,11

SRLD-13,15,17

SF

SF

SRLD-19,21,23

SRLD-14,16,18

SF

SF

SRLD-20,22,24

SRLD-2,4,6

SF

SF

SRLD-8,10,12

12 12 12 12

12 12 12 12

7 VAV-12-10

TV

SRLB-3 (SC)

TV

SRLA-28

TV

SRLB-24

TV

SRLB-26

SRLB-16

SRLB-18

48" AFF

48" AFF

26 26

1/8" = 1'-0"

POWER PARTIAL FLOOR PLAN - AREA K

1/8" = 1' - 0" 0 5' 10' 15' 30'

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEY PLAN

GRAPHIC SCALE

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:2

P

M

P N

F

Y

/2

/2

EP110

P O

W E

R P

A R

T

IA

L F

L O

O R

P L A

N

A R

E A

K

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

GENERAL NOTES (THIS SHEET ONLY)

1. FOR SECURITY ACCESS FACILITY PLAN SEE SHEET EP402.

2. SYSTEMS FURNITURE RECEPTACLES SHALL HAVE HALF RECEPTACLES

SWITCHED BY TIME CLOCK AND CIRCUITED TO PHASE 'A' OF CIRCUITS

LABELED FOR SYSTEMS FURNITURE.

3. COORDINATE SYSTEMS FURNITURE JUNCTION BOX WITH SYSTEMS

FURNITURE APPROVED SHOP DRAWINGS.

4. SYSTEM FURNITURE CIRCUITS ON 'A' PHASE SHALL CONTROL HALF

RECEPTACLES IN EACH CUBICLE.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

T E

OFFICE

OFFICE

STORAGE

MALE

LATRINE

FEMALE

LATRINE

WATER

HEATER

MUD ROOM

JANITOR

RTOC

RTOC

CORRIDOR

CORRIDOR

EP401

B3

P

P

J

K

R

Q.7

Q

Q.1

P

N

M

L

17 18 19 22

M A

T C

H

LI

N E

MATCHLINE

GFI

GFI GFI

GFI

GFI

GFI GFI

GFIGFI

GFI

PP

M A

T C

H

LI

N E

MATCHLINE

MATCHLINE

ERLA-9

GFI

ERLA-5

ERLA-3

ERLA-1

GFI

ERLA-7

ERLA-11

ERLA-15

ERLA-13

ERLA-19

ERLA-17

ERLA-21

ERLA-23

ERLA-25

ERLB-25

ERLB-29

ERLB-20

ERLB-16

ERLB-14

ERLB-31

CORRIDOR

CORRIDOR

OFFICE

CAGED

STORAGE

CAGED

STORAGE

EP404

B1

ERLB-27

ERLB-18

FROM CU-05

ON ROOF

SS-05

UH-01

UH-02

20 21

8VAV-10-15

VAV-10-09

VAV-10-108 8

9VAV-11-11

9 VAV-11-01

9 VAV-11-02

9VAV-11-09

SAT ESS

ELEC

WP/GFI

ERLA-20

ERLA-18

ERLA-16ERLA-14

10 10

ERLB-1,3,5

1,3,55

ERLB-7,9,11

7,9,11

ERLB-13,15,17

ERLB-19,21,23

19,21,23

13,15,17

T

T

T

T T

T

T

T T

T

T

T

TT

T T

T

T

UH-07

R

R

R

R R

R

R

RR

R

R R R

R

R

R

R

R

RRR

R R R

ERLA-35

EDH-8,10,12

TO EF-02 ON

ROOF SEE

SHEET EP-116

23 23

23 23

23 23

1/8" = 1'-0"

POWER PARTIAL FLOOR PLAN - AREA L

1/8" = 1' - 0" 0 5' 10' 15' 30'

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEY PLAN

GRAPHIC SCALE

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:2

P

M

P N

F

Y

/2

/2

EP111

P O

W E

R P

A R

T

IA

L F

L O

O R

P L A

N

A R

E A

L

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

GENERAL NOTES (THIS SHEET ONLY)

1. FOR SECURITY ACCESS FACILITY PLAN SEE SHEET EP402.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

MAIN ELEC

MECHANICAL

FIRE PUMP

STAIR

STORAGE

AAR

AV

STORAGE

CAGED

STORAGE

CAGED

STORAGE

STORAGE

CORRIDOR

CORRIDOR

EP401

A1

EP402

B4

H.2

H

G

F

E

D

C

B

J

K

L

17 18 19 22

M A

T C

H

LN

E

MATCHLINE

M A

T C

H

LI

N E

RECYCLED

STORAGE

STORAGE

P

P

P

MATCHLINE

ERLA-2

ERLA-4

ERLA-10

ERLA-6

ERLA-8

MRLA-4

MRLA-2

OFFICE

MRLA-5

MRLA-3 (SC)

OFFICE

CAGED

STORAGE

CAGED

STORAGE

CRAC-13

MDH-13,15,17

MDH-25,27,29

CRAC-14

UH-03

MDH-51

UH-05

20 21

AC-01

ERLB-30,32

WP/GFI

WP/GFIWP/GFI

T

T

T

T

T

T

T

T

WP/GFI

ERLA-30

ERLA-34

ERLA-36

ERLA-38

ERLA-12

MRLA-1

TV

TV

+11'-0" ABOVE

ELEVATION 0'-0" TOS

+11'-0" ABOVE

ELEVATION 0'-0" TOSAV RACK

CUL3-12

ERLA-26

ERLA-28

ERLB-40 (SC)

ERLB-40 (SC)

DIS-5 (SC)

MHL-1

ERLB-42

TO EF-04 ON ROOF

SEE SHEET EP-116

MRLA-9

23 23

MHL-20

FOR GAS METER

1/8" = 1'-0"

POWER PARTIAL FLOOR PLAN - AREA M

1/8" = 1' - 0" 0 5' 10' 15' 30'

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEY PLAN

GRAPHIC SCALE

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:4

P

M

P N

F

Y

/2

/2

EP112

P O

W E

R P

A R

T

IA

L F

L O

O R

P L A

N

A R

E A

M

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

GENERAL NOTES (THIS SHEET ONLY)

1. FOR SECURITY ACCESS FACILITY PLAN SEE SHEET EP402.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

TR ROOM

RTOC

RTOC

RTOC

RTOC

RTOC

ELEC.ROOM

RTOC

EP401

A3

EP406

B3

P P

P P P

P

J

K

R

Q.7

Q

Q.1

P

N

M

L

22 23 24 25 26 27 28 29 30 31

M A

T C

H

LI

N E

MATCHLINE

P P

P P

P P

MATCHLINE

ERLB-22 ERLC-27 ERLC-16

ERLA-24

ERLD-15ERLC-24 ERLD-18

ERLD-20

ERLD-14

ERLD-13

ERLD-19

ERLC-28

ERLC-26

ERLC-14

ERLC-29

ERLC-31

ERLB-28

ERLB-26

ERLA-22 CORRIDOR

ERLC-20

ERLB-24

ERLC-25 ERLC-18 ERLC-22 ERLD-17

ERLD-16

CRAC-12

EDH-19,21,23

FROM CU-06

ON ROOF

SS-06

9 VAV-11-03

9 VAV-11-04 9 VAV-11-05 9 VAV-11-06 9 VAV-11-07 9 VAV-11-08

9VAV-11-12

WP/GFI

8,10,12

6 2,4,6

ERLB-2,4,6

ERLB-8,10,12

5 1,3,5

ERLC-1,3,5

7,9,11

ERLC-7,9,11

17 13,15,17

ERLC-13,15,17

ERLC-19,21,23

19,21,23

6 2,4,6

ERLC-2,4,6

ERLC-8,10,12

8,10,12

5 1,3,5

ERLD-1,3,5

7,9,11

ERLD-7,9,11

6 2,4,6

ERLD-2,4,6

ERLD-8,10,12

8,10,1212

9 VAV-11-10

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

ERLC-39

23 23

23 23 23 23 23 23

1/8" = 1'-0"

POWER PARTIAL FLOOR PLAN - AREA N

1/8" = 1' - 0" 0 5' 10' 15' 30'

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEY PLAN

GRAPHIC SCALE

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:4

P

M

P N

F

Y

/2

/2

EP113

P O

W E

R P

A R

T

IA

L F

L O

O R

P L A

N

A R

E A

N

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

GENERAL NOTES (THIS SHEET ONLY)

1. FOR SECURITY ACCESS FACILITY PLAN SEE SHEET EP402.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

TRAINING

SUPPLY

STORAGE

DISINTEGRATOR

CORRIDOR

H.2

H

G

F

E

D

C

B

J

22 23 24 25 26 27

M A

T C

H

LI

N E

MATCHLINE

STORAGE

MATCHLINE

EP502

A1

WP/GFI

ERLB-34,36,38

DOCK LEVELER

ERLB-40 (SC)

MRLA-3 (SC)

MRLA-11

1/8" = 1'-0"

POWER PARTIAL FLOOR PLAN - AREA P

1/8" = 1' - 0" 0 5' 10' 15' 30'

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEY PLAN

GRAPHIC SCALE

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:5

P

M

P N

F

Y

/2

/2

EP114

P O

W E

R P

A R

T

IA

L F

L O

O R

P L A

N

A R

E A

P

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

GENERAL NOTES (THIS SHEET ONLY)

1. FOR SECURITY ACCESS FACILITY PLAN SEE SHEET EP402.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

H.2

H

G

F

E

D

C

B

A.8

A.4

1 2 3 4 5 6 7 9

J

K

U.1

U

T

S

R

Q.7

Q

Q.1

P

N

M

L

11 12 13 14

A

15 16 17 18

MATCHLINE

M A

T C

H

LI

N E

CU-09

TO SS-09

IN RM 091

EF-07

SDH-2,4,6

RTU-12

CH-01

CU-04

CRLG-13,15

CDH-14,16,18

RTU-10

CDH-8,10,12

RTU-08

ACC-07 WRLE-22,24

CU-02

TO SS-02 IN

RM. 031

WDH-8,10,12

RTU-05

WDH-14,16,18

RTU-06

EF-01

RTU-01

WDH-2,4,6

RTU-02

ACC-14

TO SS-04

IN RM. 086

ACC-13

EF-03

CU-10

SRLA-39,41

SDH-8,10,12

MDH-32,34,36

SRLA-35,37

CU-07

TO SS-07

IN RM. 149

TO SS-10

IN RM. 141

CRLG-17,19

WP/GFI WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WRLE-23 (SC)

WRLE-23 (SC)

CRLG-14

CRLG-16

WRLE-35,37

CU-08

TO SS-08 IN

RM. 001A

WDH-19,21,23

MDH-31,33,35

MDH-37,39,41

P

SEE DETAIL A2, SHEET EL511.

P

SEE DETAIL A4, SHEET EL511.

TO MOTOR

STARTER IN

ROOM 149

TO MOTOR

STARTER IN

ROOM 149

TO MOTOR

STARTER IN

ROOM 007

MRLA-13

CH-01 HT

30 30

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:1

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:1

P

M

P N

F

Y

/2

/2

EP115

P A

R T

IA

L E

L E

C T

R

IC

A L R

O O

F P

L A

N

P O

W E

R

A R

E A

A

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GRAPHIC SCALE

A

C

B

PLAN

NORTH

KEY PLAN

1/16" = 1'-0"

PARTIAL ELECTRICAL ROOF PLAN - POWER - AREA A

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

G

F

E

D

C

B

A.8

A.4

J

K

U.1

U

T

S

R

Q.7

Q

Q.1

P

N

M

L

V

A

19 22 23 24 25 26 27 28 29 30 31

M A

T C

H

LI

N E

EF-08

EF-05EF-06

MDH-2,4,6

RTU-03 RTU-04 MDH-8,10,12

EF-04

ERLC-33,35

CU-05

ERLC-30,32

RTU-11

EDH-2,4,6

TO SS-05 IN

RM. 115

TO SS-06 IN RM. 121

CU-06

ACC-12

20 21

WP/GFI WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

WP/GFI

ERLA-27

MRLA-7

EF-10

EDH-13,15,17

P

SEE DETAIL A5, SHEET EL511.

WP/GFI

TO MOTOR

STARTER IN

ROOM 126

TO MOTOR

STARTER IN

ROOM 128

EF-09

TO MOTOR

STARTER IN

ROOM 136

TO MOTOR

STARTER IN

ROOM 136

TO MOTOR

STARTER IN

ROOM 131

TO MOTOR

STARTER IN

ROOM 132

TO MOTOR

STARTER IN

ROOM 098

EF-02

30 30

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:2

P

M

P N

F

Y

/2

/2

EP116

P A

R T

IA

L E

L E

C T

R

IC

A L R

O O

F P

L A

N

P O

W E

R

A R

E A

B

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GRAPHIC SCALE

A

C

B

PLAN

NORTH

KEY PLAN

1/16" = 1'-0"

PARTIAL ELECTRICAL ROOF PLAN - POWER - AREA B

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

6 7 9 10 11 12 13 14

EE

DD

CC

BB

AA

Z

Y

X

W

V

15 16 17 18

MATCHLINE

ACC-15

NDH-31,33,35

NRLG-2,4

TO SS-03 IN RM. 062

ACC-08

NDH-2,4,6

RTU-07

NDH-8,10,12

RTU-09

NDH-14,16,18

RTU-13

CU-03WP/GFI

WP/GFI

WP/GFI

NRLG-13

NDH-19,21,23

P

SEE DETAIL A3, SHEET

EL511.

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:3

P

M

P N

F

Y

/2

/2

EP117

P A

R T

IA

L E

L E

C T

R

IC

A L R

O O

F P

L A

N

P O

W E

R

A R

E A

C

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP101 FOR NOTES)

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GRAPHIC SCALE

A

C

B

PLAN

NORTH

KEY PLAN

1/16" = 1'-0"

PARTIAL ELECTRICAL ROOF PLAN - POWER - AREA C

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

WRLC

WRLE

WRLD

WRLA

WDL

TWDL

WDH

WLH

K

M

L

ELEC.

ROOM

LCP

WRLB

TWUL1

TWUL2

100A TO

WUL2

100A TO

WUL1

CULESS-5

CULESS-7

20 CULESS-9

NRLD NRLGNRLFNRLBNRLA

NDL

TNDL

NDH

AA

Z

ELEC

NRLE

LCP

NRLC

TNULA1 TNULA2

NLH

150A TO

NULA1

150A TO

NULB1

150A TO

NULA2

150A TO

NULB2

BID OPTION NO. 03, SEE

SHEET EG105-EG106

CULESS-11

CULESS-13

CRLH

CRLGCRLFCRLECRLDCRLCCRLBCRLA

CDL

TCDL

CDH

CLH

J

K

L

ELEC.

ROOM

LCP

25 TEDL

EDH

EDL

ERLA

K

L

ELEC

ELH

ERLB

TEUL2

TEUL1

LCP

100A

100A

TO PANEL EUL1

TO PANEL EUL2

CULESS-8

CULESS-6

ERLC

ERLD

J

K

ELEC.ROOM

MAIN ELEC

D

C

B

MUDP

MLH

MDH

TMDL

MDL

MRLA

UPS BATTERIES (TYPICAL)

UPS1 BYPASS

TCUL1

UPS2 BYPASS

LCP

800A

FRONT

MAIN

SWITCHBOAR

D (MSB)

3 1/2"

CONCRETE

PAD

TROLLEY RAIL

20 KVA CENTRAL

INVERTER

20 KVA INVERTER

BATTERY CABINET

TCUL2

800A

MULDP

UPS2UPS1

NEMA 4 ENCLOSURE

FOR FUTURE

GENERATOR

CONNECTION

MRLA-615

TO PANEL CUL1

TO PANEL CUL2

FUTURE

STANDBY

GENERATOR

SECTION

FUTURE

METERING

SECTION

MHL-13

MUDP-37,39,41

TO EF-10 ON ROOF

SEE SHEET EP-116

TO EF-09 ON ROOF

SEE SHEET EP-116

34 36

SLHSDH

SDL

SRLA SRLB SRLC SRLD

TSDL

F

ELEC

LCP

RECEPT.

LCP

SRLA-31

SRLA-33

TO EF-03 ON ROOF

SEE SHEET EP-115

TO EF-07 ON

ROOF SEE

SHEET EP-115

CULESS-19

CULESS-17

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:5

P

M

P N

F

Y

/2

/2

EP401

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/4" = 1'-0" A5

ENLARGED ELECTRICAL

ROOM 031

1/4" = 1'-0" C1

ENLARGED ELECTRICAL ROOM 062

1/4" = 1'-0" C2

ENLARGED ELECTRICAL ROOM 086

NOTES# (APPLY TO SHEET EP401- EP407)

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

1 JUNCTION BOX (4" SQUARE X 2 1/8" DEEP) FOR SENSOR FLUSH SYSTEM,

MOUNT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED MOUNTING

HEIGHT. COORDINATE WITH EQUIPMENT LOCATION ON ARCHITECTURE AND

PLUMBING DRAWINGS. RUN 3/4" CONDUIT TO ABOVE CEILING.

2 JUNCTION BOX (4" SQUARE X 2 1/8" DEEP) FOR SENSOR FLUSH SYSTEM,

MOUNT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED MOUNTING

HEIGHT. COORDINATE WITH EQUIPMENT LOCATION ON ARCHITECTURE AND

PLUMBING DRAWINGS. RUN CONDUIT TO JUNCTION BOX ABOVE.

3 JUNCTION BOX (4" SQUARE X 2 1/8" DEEP) FOR SINK AUTO ON/OFF SENSOR,

MOUNT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED MOUNTING

HEIGHT. COORDINATE WITH SINK TRANSFORMER AND EQUIPMENT LOCATION

ON ARCHITECTURE AND PLUMBING DRAWINGS.

4 225A BUS DUCT, PROVIDE ENCLOSURE WITH 1 L5-30 PER RACK. MOUNT +7'-6"

AFF

5 PROVIDE 208V, SINGLE PHASE, 30A LOCKING DUPLEX RECEPTACLE, MOUNT

ON RACK RUNWAY.

6 SURFACE MOUNT +24" AFF.

7 ELECTRICAL CONNECTION FOR 120V-24V TRANSFORMER MOUNTED ABOVE

CEILING.

8 NOTIFICATION CIRCUIT POWER BOOSTER CONNECTION, 120V.

9 NITROGEN GENERATION SYSTEM CONNECTION, 120V.

10 JOCKEY PUMP CONTROL PANEL CONNECTION, 480V.

11 FIRE PUMP CONTROLLER CONNECTION, 480V.

12 FIRE ALARM CONTROL PANEL CONNECTION, 120V.

13 FIRE ALARM MASS NOTIFICATION PANEL CONNECTION, 120V.

14 FEEDER SHALL BE FEED FROM FIRE PUMP SECTION IN THE MAIN

SWITCHGEAR. SEE ELECTRICAL SINGLE-LINE DIAGRAM ON SHEET EP701.

15 DISCONNECT PROVIDED WITH INVERTER.

16 (BID OPTION NO. 03 60KW INVERTER FOR PHOTOVOLTAIC SYSTEM), MOUNT

ON HOUSE KEEPING PAD EXTENDING 3" AROUND EQUIPMENT BY 3 1/2" DEEP.

17 FROM COMBINER BOX ON ROOF, SEE SHEET EG108.

18 TO GROUND RING SEE SHEET EG102.

19 MOTOR STARTER, SEE MOTOR EQUIPMENT SCHEDULE LOCATED ON EP601.

20 SECURITY FIELD DISTRIBUTION.

21 CONNECTION FOR USE BY CONTROL CONTRACTOR TO SUPPORT CONTROL

PANELS. COORDINATE LOCATION WITH CONTROL CONTRACTOR.

22 EQUIPMENT EMERGENCY SHUTDOWN SWITCH, MOUNT 60" AFF. SEE DETAIL

'C4' THIS SHEET.

23 HVAC EMERGENCY SHUTDOWN SWITCH, MOUNT 60" AFF. SEE DETAIL 'C4' THIS

SHEET.

24 EXOTHERMICALY BOND GROUND BAR TO STRUCTURAL STEEL WITH 4/0 AWG.

25 PROVIDE HOUSEKEEPING PAD 4" BEYOND EQUIPMENT OUTLINE AND

3 1/2" THICK.

26 POLES PROVIDED BY TELECOMMUNICATIONS SEE NOTE 5 ON SHEET T-408.

27 FOR DOOR POWER SUPPLY, 120V.

28 TO DOOR POWER SUPPLY DISCONNECT IN ELECTRICAL ROOM 062. PROVIDE

2#8, 1#10 GND.

29 TO DOOR POWER SUPPLY DISCONNECT IN ELECTRICAL ROOM 149. PROVIDE

2#8, 1#10 GND.

30 TO DOOR POWER SUPPLY DISCONNECT IN ELECTRICAL ROOM 031. PROVIDE

2#8, 1#10 GND.

31 TO DOOR POWER SUPPLY DISCONNECT IN ESS ROOM 091. PROVIDE 2#8, 1#10

GND.

32 TO DOOR POWER SUPPLY DISCONNECT IN ELECTRICAL ROOM 115. PROVIDE

2#8, 1#10 GND.

33 FROM COMBINER BOX ON ROOF, SEE SHEET EG109.

34 DUCTBANK SEE DETAIL A3 SHEET ES501. EMPTY FOR FUTURE ENGINE

GENERATOR CONNECTION.

35 2" CONDUIT WITH PULL WIRE FROM ESS ROOM 091. RUN TO WIRE WAY SEE

DETAIL 'C1' ON TY001.

36 DUCTBANK SEE DETAIL A3 SHEET ES501 TO PAD MOUNT TRANSFORMER.

37 SEE GROUNDING DIAGRAM ON SHEET EP705.

1/4" = 1'-0" B3

ENLARGED ELECTRICAL

ROOM 115

1/4" = 1'-0" A3

ENLARGED ELECTRICAL

ROOM 121

1/4" = 1'-0" A1

ENLARGED MAIN ELECTRICAL ROOM 136

1/4" = 1'-0" C4

ENLARGED ELECTRICAL ROOM 149

GENERAL NOTES (THIS SHEET ONLY)

1. FOR TRANSFORMER HOUSEKEEPING PADS SEE SHEET E-001.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

6 7

CU-01

ECF-1,3

SS-01

TO SS-01, BELOW

ECF

+48" AFF

ECF-2

WP/GFI

WP/GFI

ECF-4

ECF-8

ECF-6

RC

EL509

A3

W3A

W3A

W3A

W3A

W3A

W3A

ECF-7 (SC)

Y2 Y2X2

A4AD A4AD

A4ADA4AD

Y1A

Y1A

ECF-5

,ON ROOF

FROM CU-01

ON ROOF

ECF-7 (SC)

SECURITY

ACCESS

FACILITY

ESS

CULESS

CULESS-4

CULESS-2

CULESS-3

CULESS-1ES1

ES2

CRLG-25 CRLG-27

CULESS-12

CULESS-14

CULESS-16 27

CULB1 CULB2

SIPR TR

CULB1-2

CULB2-2

CULB1-4

CULB2-4

CULB2-3

CULB1-3

CULB2-1

CULB1-1

S1 S2 S3 S4

CULB1-6

CULB1-10

CULB1-8

C

B

MECHANICAL

BP-1

MDH-19,21,23

HWP-1

HWP-2

MDH-14,16,18

MDH-20,22,24

B-1 B-2 B-3

UH-04

MDH-49

MHL-2 MHL-4 MHL-6

VFD

VFD

MHL

MHL-10

FIRE PUMP

13214

MHL-12, 14, 16

MHL-3,5

MHL-7

19 19

TO EF-06 ON ROOF

SEE SHEET EP-116

TO EF-05 ON ROOF

SEE SHEET EP-116

MHL-9

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:0

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:0

P

M

P N

F

Y

/2

/2

EP402

S E

C U

R

IT

Y A

C C

E S

S F

A C

IL

IT

Y A

N D

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NOTES# (SEE SHEET EP401 FOR NOTES)

1/2" = 1' - 0" 0 1' 5'6" 2' 3' 4'

GRAPHIC SCALE

1/4" = 1' - 0" 0 5' 10' 15'1'

1/2" = 1'-0"

SECURITY ACCESS FACILITY

1/4" = 1'-0" C1

ENLARGED ESS

ROOM 091

1/4" = 1'-0"

C4

ENLARGED SIPR TR ROOM 093

1/4" = 1'-0" B4

ENLARGED MECHANICAL ROOM 131

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

J

2 1

WRLE-17

RCP-1

GWH-1

GWH-2

FEMALE

LATRINE

WRLE-39

G

F

E

D

C

1 1 1 1

3 3

3 3

MALE

LATRINE

MINI

LOCKERS

MENS

WOMENS

WRLE-41

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:0

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:0

P

M

P N

F

Y

/2

/2

EP403

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/4" = 1'-0" A3

ENLARGED FEMALE LATRINE ROOM 009

1/4" = 1'-0"

A1

ENLARGED MALE LATRINE ROOM 005

NOTES# (SEE SHEET EP401 FOR NOTES)

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

Q

P

N

M

18 19

1 2

RCP-2

GWH-3

GWH-4

ERLA-37

7 7 7 7

1 2

1 2

ERLA-31

FEMALE

LATRINE

MALE

LATRINE

ERLA-33

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:1

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:1

P

M

P N

F

Y

/2

/2

EP404

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/4" = 1'-0" B1

ENLARGED LATRINE PLANS

NOTES# (SEE SHEET EP401 FOR NOTES)

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

G

14 15 16

CUL1 CUL2

MCER

4 CUL1-2,4,6

CUL2-2,4,6

4CUL1-10,12,14

4CUL2-10,12,14

4 CUL1-18,20,22

4 CUL2-18,20,22

4CUL1-26,28,30

4CUL2-26,28,30

4 CUL1-34,36,38

4 CUL2-34,36,38

4CUL2-42,44,46

4CUL1-42,44,46

R1

R2

R3

R4

R5

R6

R7

R8

R9

R18

R17

R16

R15

R14

R13

R12

R11

R10

P1

P2

P3

P4

P5

P6

P7

P8

P9

B9

B8

B7

B6

B5

B4

B3

B2

B1

B10

B11

B12

B13

B14

B15

B16

B17

B18

A9

A8

A7

A6

A5

A4

A3

A2

A1

CUL3-11

CUL3-9

CUL3-8

CUL3-7

CUL3-6

CUL3-5

CUL3-4

CUL3-3

CUL3-2

CUL3-1

4 CUL2-33,35,37

4 CUL1-33,35,37

CUL3-10

C6

C5

C4

C3

C2

C1

CUL3

AC

AC

AC AC

AC AC

CHH

EM EM

EMERGENCY SHUT DOWN MUSHROOM

PUSH-PULL SWITCH WITH LIFT UP

PROTECTION. MOUNT 60" AFF

EQUIPMENT

POWER

EMERGENCY

SHUT DOWN

HVAC

EMERGENCY

SHUT DOWN

LABEL 6" X 6" LABEL 6" X 6"

S

N

MAIN BREAKER

PANELBOARD CHH

PANELBOARD CUL1

S

S

S

S

S

S

S

N

CKT #53

CKTS #33,35,37

CKTS #2,4,6

CKTS #10,12,14

CKTS #18,20,22

CKTS #26,28,30

CKTS #34,36,38

CKTS #42,44,46

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:1

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:1

P

M

P N

F

Y

/2

/2

EP405

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/4" = 1'-0" B1

ENLARGED MCER ROOM 090

NOTES# (SEE SHEET EP401 FOR NOTES)

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

NO SCALE

C4

MCER ROOM 090 EMERGENCY

SHUT DOWN DETAIL

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

G

CULC2 CULC1

NIPR TR

N6

N5

N4

N3

N2

N1

CULC1-1

CULC2-1

CULC1-3

CULC2-3

CULC1-5

CULC2-5

CULC1-2

CULC2-2

CULC1-4

CULC2-4

CULC1-6

CULC2-6

CULC1-7

CULC1-11 CULC1-9

CULC1-13

P

N

TR ROOM

WUL1

WUL2

B3G3

G2

G1 B1

B2 R2

R1

R3WUL2-1

WUL1-1

WUL1-3

WUL2-3

WUL2-5

WUL1-5

WUL2-2

WUL1-2

WUL1-4

WUL2-4

WUL2-6

WUL1-6

WUL2-7

WUL1-7

WUL1-9

WUL2-9

WUL2-11

WUL1-11

WRLE-34

WRLE-368

WUL2-8

WUL1-8

WUL1-16

WUL1-10

WUL1-12

WUL1-14

AV

J

K

TR ROOM

087 CULA2

CULA1

R3

R2

R1

B3

B2

B1

G3

G2

G1

CULA1-5

CULA2-5

CULA2-3

CULA1-3

CULA2-1

CULA1-1

CULA1-6

CULA2-6

CULA2-4

CULA1-4

CULA2-2

CULA1-2

CULA1-11

CULA2-11

CULA2-9

CULA1-9

CULA2-7

CULA1-7

CRLG-22

CRLG-20

CULA1-16

CULA1-14

CULA1-12

CULA1-10AV

CULA1-8CULA2-8

D

SUL2 SUL1

TR ROOM

G2G3 G1

SUL2-1

SUL1-1

SUL2-3

SUL1-3

SUL2-5

SUL1-5 SUL1-6

SUL1-2

SUL1-4

CULESS-21 27

TR ROOM

J

K

L

22 23

EUL2

EUL1

G1

G3

G2

B1

B2

B3

R1

R2

R3

EUL2-2

EUL1-4

EUL1-2

EUL2-6

EUL1-6

EUL2-4

EUL2-7

EUL1-9EUL1-7

EUL2-11 EUL1-11

EUL2-9

EUL1-1

EUL2-1

EUL1-3

EUL2-3

EUL1-5

EUL2-5

ERLC-34

ERLC-36

EUL1-8

EUL1-10

EUL1-12

EUL1-14

EUL1-18

EUL1-16

EUL1-13 EUL2-13CULESS-10 27

AV

AA

Z

NULA2NULA1

TR ROOM

B4 B3 B2 B1

G1G2G3G4

R4 R3 R2 R1

NULA1-1

NULA2-1

NULA1-3

NULA2-3NULA1-5

NULA2-5

NULA1-7

NULA2-7

NULA1-2

NULA2-2

NULA1-4

NULA2-4NULA1-6

NULA2-6

NULA1-8

NULA2-8

NULA1-11

NULA2-11

NULA1-13

NULA2-13

NULA1-15

NULA2-15

NULA1-17

NULA2-17

NULA1-12

NULA1-22

NULA1-18

NULA1-14

NULA1-16

NULA1-20

NRLG-14

NRLG-16

AV

NULA2-10

NULA1-10

NULA1-19

NULA2-19

NULA2-9

NULA1-9

CULESS-15 27

G5

R5

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:2

P

M

P N

F

Y

/2

/2

EP406

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/4" = 1'-0" C1

ENLARGED NIPR TR ROOM 094

1/4" = 1'-0"

C2

ENLARGED TR ROOM 030

1/4" = 1'-0" C4

ENLARGED TR ROOM 087

1/4" = 1'-0" A3

ENLARGED TR ROOM 141

1/4" = 1'-0" B3

ENLARGED TR ROOM 120

1/4" = 1'-0" A1

ENLARGED TELECOM ROOM 061

NOTES# (SEE SHEET EP401 FOR NOTES)

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

DD

CC

BB

AA

Z

15 16 17

NULB2

NULB1

SECURE

ROOM

STORAGE

OFFICE

VEST.

TR

VEST.

NRLH

JWICS

SIPR

NIPR

NULB2-12,14

NULB1-12,14

NULB2-1,3

NULB1-1,3

NULB2-8,10

NULB1-8,10

NRLH-5

NRLH-9

NRLH-20 NRLH-22

NRLH-24 NRLH-28

NRLH-34

NRLH-36

NRLH-30

NRLH-32

NRLH-38

NRLH-40

NRLH-10 NRLH-12

NRLH-13

NULB1-4

NULB1-2

NULB1-6

NRLH-7

NRLH-1

NRLH-3

NRLH-26

NRLH-8

NRLH-18

NRLH-16

NRLH-14

NRLH-11

SIPR

SIPR

NULB1-5,7

NULB2-5,7

NULB1-9,11

NULB2-9,11

NULB1-13,15

NULB2-13,15

JWICS

JWICS

JWICS

26 26

28 28

6" 6"

MAX MAX

SECURE SIDENON-SECURE SIDE

STRUCTURAL DECK

CONDUIT

CONDUIT

SEALANT ALL AROUND

BOTH SIDES

GWB

SCHEDULE 40 PVC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:3

P

M

P N

F

Y

/2

/2

EP407

E N

L A

R G

E D

E L E

C T

R

IC

A L P

L A

N S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/4" = 1'-0" B2

ENLARGED SECURE ROOM 065

NOTES# (SEE SHEET EP401 FOR NOTES)

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

NO SCALE

A1

CONDUIT PENETRATION OF SECURE WALL

GENERAL NOTES (THIS SHEET ONLY)

1. WALL MOUNTED RECEPTACLES SHALL BE SURFACE MOUNTED. BELOW

CEILING STRUCTURE UTILIZE METAL SURFACE RACEWAYS ON WALLS AND,

COLUMNS. ABOVE CEILING STRUCTURE UTILIZE METAL CONDUIT RACEWAYS.

2. SUPPORTS FOR SURFACE MOUNTED EQUIPMENT SHALL BE ALIGNED WITH

WALL STUDS WITH MOUNTING SCREWS ENGAGING STUDS. DRYWALL

ANCHORS SHALL NOT BE USED TO SUPPORT EQUIPMENT UNLESS THIS IS THE

ONLY OPTION.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

INCOMING

CABLE

TERMINATION

SECTION

FIRE PUMP

SECTION

SDH

WDH

UPS1

CDH

NDH

UPS1

EDH

MDH

SPARE PROVISIONSSPARE METERING

MCB

SPARE

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:3

P

M

P N

F

Y

/2

/2

EP501

E L E

C T

R

IC

A L D

E T

A

IL

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NO SCALE

C1

MSB SWITCHGEAR ELEVATION

NOTES# (APPLY TO SHEETS EP501 AND EP503)

1 3/4" KNOCKOUTS.

2 BRASS FLANGE RING AND COVER PLATE.

3 CONCRETE SLAB.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

D

C

B

24 25 26

RELOCATED

DISINTEGRATOR

MOTOR STARTER

RELOCATED

CONTROL

PANEL

RELOCATED DUST

FILTER UNIT

RELOCATED TRASH

COLLECTOR

DIS

RELOCATED FUSED

DISCONNECT 200 AMP

WITH 125 AMP FUSES

NEW FUSED SAFTEY

SWITCHES 30 AMP

RELOCATED

CYCLONE FAN

MOTOR (ABOVE)

RELOCATED

AIRLOCK MOTOR

(BELOW)

RELOCATED

CONVEYOR

DIS-9,11

DIS-7

RELOCATED

FILTER SHAKER

DIS-5 (SC)

DIS-2

WP/GFI

DIS-1,3

WIREWAY

TO EF-08 ON ROOF

SEE SHEET EP-116

UH-06

DISINTEGRATOR

EXISTING CONTROL PANEL (RELOCATE)

EXISTING CONVEYOR (RELOCATE)

EXISTING

DISINEGRATOR

MOTOR 75 HP

(RELOCATE)

EXISTING MOTOR

STARTER NEMA

SIZE 4 (RELOCATE)

EXISTING FUSED

DISCONNECT 200

AMP WITH 125 AMP

FUSES (RELOCATE)

EXISTING (TO REMAIN)

PANELBOARD HV-1

480Y/277V

EXISTING (TO REMAIN)

PANELBOARD LV-1

208Y/120V

EXISTING CYCLONE

FAN/MOTOR

(RELOCATE)

EXISTING ROTARY

AIRLOCK MOTOR

(RELOCATE)

FROM MDH-26,28,30 WIREWAY

RELOCATED FUSED

DISCONNECT 200 AMP

WITH 125 AMP FUSES

NEW FUSED 30A

SAFTEY SWITCH

RELOCATED MOTOR

STARTERS

M M M

DISINTEGRATOR

CYCLONE FAN AIR LOCK

PANEL DIS

208Y/120V

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:4

P

M

P N

F

Y

/2

/2

EP502

E L E

C T

R

IC

A L D

E T

A

IL

S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

AND ROTARY AIRLOCK MOTOR

NO SCALE

DISINTEGRATOR FILTER SHAKER

NO SCALE

DISINTEGRATOR - CONTROL PANEL

NO SCALE

DISINTEGRATOR AND DUST FILTER

NO SCALE

DISINTEGRATOR DUST FILTER

CYCLONE

FAN MOTOR

TRASH COLLECTOR

1/4" = 1'-0" A1

RELOCATED DISINTEGRATOR ENLARGED PLAN - ROOM 128

1/4" = 1'-0"

EXISTING DISINTEGRATOR

1 2

DISINTEGRATOR - CONVEYOR

NO SCALE

DISINTEGRATOR MOTOR STARTER

NO SCALE

DUST FILTER SHAKER

AIRLOCK

MOTOR

STARTER

ON/OFF

FAN MOTOR

CYCLONE

STARTER

CONVEYOR SPEED CONTROL

NO SCALE

DISINTERATOR ELECTRICAL

SINGLE-LINE DIAGRAM

GENERAL NOTES

1.

2.

3.

4.

5.

6.

(THIS SHEET ONLY)

PROVIDE ELECTRICAL DEMOLITION AND ELECTRICAL CONSTRUCTION

INCLUDING NEW RACEWAYS AND WIRING TO RELOCATE A MODEL 1424

DISINTEGRATOR AS MANUFACTURED BY SECURITY ENGINEERED MACHINERY

CO. INC. (SEM) FROM BUILDING 4407 TO THE MISSION TRAINING COMPLEX.

DOCUMENT EXISTING ELECTRICAL CONNECTIONS AND WIRING SUCH THAT

ELECTRICAL OPERATION OF THE DISINTEGRATOR CAN BE RESTORED AFTER

RELOCATION.

DISCONNECT AND REMOVE ALL ELECTRICAL COMPONENTS AND CONTROLS TO

ALLOW RELOCATION OF THE DISINTEGRATOR.

AFTER DISINTEGRATOR HAS BEEN RELOCATED REINSTALL ELECTRICAL

COMPONENTS AND PROVIDE NEW WIRING TO RESTORE THE DISINTEGRATOR

TO PRE RELOCATION OPERATION.

INTERIOR WIRING EMT AND FMC FOR FINAL CONNECTIONS TO MOTORS OR

EQUIPMENT SUBJECTED TO VIBRATION.

EXTERIOR WIRING RGS AND LFMC FOR FINAL CONNECTIONS TO MOTORS OR

EQUIPMENT SUBJECTED TO VIBRATION.

DISINTEGRATOR

MOTOR STARTER

DISINTEGRATOR - CYCLONE FAN

ROTARY

AIRLOCK MOTOR

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE

NOTES#

1 REFER TO EQUIPMENT CONNECTION SCHEDULE ON SHEET

EP601 FOR WIRE SIZES AND DISCONNECT DESCRIPTION.

2 SEE SINGLE LINE DIAGRAM THIS SHEET.

3 AFTER REMOVAL OF ALL DISINTEGRATOR COMPONENTS,

REMOVE ALL ABANDONED CONDUIT AND WIRE, CLOSE ANY

ELECTRICAL OPENINGS AND UPDATE PANEL SCHEDULES.

4 MOTOR STARTER, SEE MOTOR EQUIPMENT SCHEDULE

LOCATED ON EP601.

5 REMOVE CONTROL PANEL. RECORD EXISTING WIRING

CONNECTIONS SUCH THAT CONTROL PANEL CAN BE

REINSTALLED WITH RELOCATED DISINEGRATOR. DEMOLISH

CONDUIT AND WIRE BACK TO SOURCE PANELBOARD. UPDATE

PANELBOARD DIRECTORY TO INDICATE SPARE POSITIONS.

(APPLY TO ONLY THIS SHEET)

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

STRUT CLAMP 100LB. CAPACITY

METAL SUPPORT

FRAME

3" J-HOOK

3" J-HOOK

12"

MINIMUM

1 5/8" X 1 5/8" UNISTRUT

2 3

SECTION VEIW

PLAN VEIW

POWER SERVICE CABLE

OUTLET (DUPLEX

RECEPTACLE)

20' POWER SERVICE

CABLE BUNDLE COILED

AROUND J-HOOK

J HOOK, SEE

DETAIL 'C1'

THIS SHEET

4" SQUARE X 2 1/4" DEEP

JUNCTION BOX MOUNTED

TO SUPPORT CHANNEL

SUPPORT CHANNEL

KELLUMS STRAIN

RELIEF GRIP

SUPPORT STRAP OR CLAMP

SWITCHED RECEPTACLE

ALWAYS ON RECEPTACLE

SWITCHED RECEPTACLE

ALWAYS ON RECEPTACLE

DUPLEX RECEPTACLE

QUADRAPLEX RECEPTACLE

TIME

CLOCK

J

CIRCUIT

FROM PANEL

TIME

CLOCK

J

CIRCUIT

FROM PANEL

10'-2" (CLASSROOM

AND WORK CELLS)

12'-2" (RTOC)

11'-2" (TECH

CONTROL) TO

BOTTOM OF

OCCUPANCY

SENSOR

10'-4"

(CLASSROOM

AND WORK

CELLS)

12'-4" (RTOC)

11'-4" (TECH

CONTROL) TO

BOTTOM OF

SPEAKER

MECHANICAL DIFFUSER, TYP.

LIGHT FIXTURE, TYP.

J-HOOK SEE DETAIL 'C1' THIS SHEET, TYP.

TELECOM

ZONE BOX

TELECOM ZONE BOX

CABLE TRAY

PROJECTION

RECEPTACLE, TYP.

SPEAKER

OCCUPANCY SENSOR

FLOOR

11'-0" (CLASSROOM AND

WORK CELLS)

13'-0" (RTOC)

12'-0" (TECH CONTROL)

CEILING HEIGHT

METAL FRAME CEILING, TYP.

2 3

SECTION VEIW

PLAN VEIW

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:4

P

M

P N

F

Y

/2

/2

EP503

E L E

C T

R

IC

A L D

E T

A

IL

S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NO SCALE

C1

J-HOOK SUPPORT AT METAL FRAME

NO SCALE

C3

DOUBLE DUPLEX POWER

FLOOR BOX

NO SCALE

A1

POWER CORD REEL

NO SCALE

C4

TOP SWITCHED RECEPTACLE DETAIL

NOTES# (SEE SHEET EP501 FOR NOTES)

NO SCALE

A2

TYPICAL CEILING MOUNTED SECTION (CLASSROOM, WORK CELL,

RTOC AND TECH CONTROL ROOMS)

NO SCALE

C2

DUPLEX POWER FLOOR BOX

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

LIGHT FIXTURE

FLOOR

8'-9"

BOTTOM OF

OCCUPANCY

SENSOR

OCCUPANCY

SENSOR

CABLE TRAY CABLE TRAY

BUS DUCT

RACK RACK

9'-0"

BOTTOM OF

LIGHT

FIXTURE

UNISTRUT SUPPORT UNISTRUT SUPPORT

10'-0"

BOTTOM OF

BUS DUCT

PANEL

G

N

PHASE 'A'

PHASE 'B'

PHASE 'C'

G

N

PHASE 'B'

PHASE 'C'

TIME

CLOCK

G

N

PHASE 'A'

SYSTEMS

FURNITURE

G

N

PHASE 'A'

N G

N N

PHASE 'B'

PHASE 'C'

G

N

PHASE 'A'

PHASE 'A'

PHASE 'B'

PHASE 'C'

JUNCTION BOX JUNCTION BOX

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:5

P

M

P N

F

Y

/2

/2

EP504

E L E

C T

R

IC

A L D

E T

A

IL

S

S P

S

R K

R

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

NO SCALE

A2

TYPICAL CEILING MOUNTED SECTION (MCER ROOM)

NO SCALE

A1

TYPICAL SYSTEMS FURNITURE WIRING DIAGRAM

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

TAG

RTU-01

RTU-02

RTU-03

RTU-04

RTU-05

RTU-06

RTU-07

RTU-08

RTU-09

RTU-10

RTU-11

RTU-12

RTU-13

HWP-1

HWP-2

CH-01

CH-01 HT

B-1

B-2

B-3

CRAC-01

CRAC-02

CRAC-03

CRAC-04

CRAC-05

CRAC-06

CRAC-07

ACC-07

CRAC-08

ACC-08

CRAC-09

CRAC-10

CRAC-11

CRAC-12

ACC-12

CRAC-13

ACC-13

CRAC-14

ACC-14

CRAC-15

ACC-15

CRAC-16

EF-01

EF-02

EF-03

EF-04

EF-05

EF-06

EF-07

EF-08

EF-09

EF-10

AC-01

SS-01

CU-01

SS-02

CU-02

SS-03

CU-03

SS-04

CU-04

SS-05

CU-05

SS-06

CU-06

SS-07

CU-07

SS-08

CU-08

SS-09

CU-09

SS-10

CU-10

UH-01, 02, 07

UH-03, 06

UH-04

UH-05

GWH-1&2/RCP-1

GWH-3&4/RCP-2

BP-1

IWH-1

IWH-2

IWH-3

IWH-4

IWH-5

JOCKEY PUMP

FIRE PUMP

DISINTEGRATOR

CYCLONE FAN

DIS ROTARY MTR

FILTER SHAKER

CONVEYOR

DOCK LEVELER

GATE

DESCRIPTION

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

ROOF TOP UNIT

HOT WATER PUMP

HOT WATER PUMP

CHILLER

HEAT TRACE

HOT WATER BOILER

HOT WATER BOILER

HOT WATER BOILER

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

CRAC CONDENSER UNIT

COMPUTER ROOM AC UNIT

CRAC CONDENSER UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

COMPUTER ROOM AC UNIT

CRAC CONDENSER UNIT

COMPUTER ROOM AC UNIT

CRAC CONDENSER UNIT

COMPUTER ROOM AC UNIT

CRAC CONDENSER UNIT

COMPUTER ROOM AC UNIT

CRAC CONDENSER UNIT

COMPUTER ROOM AC UNIT

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

EXHAUST FAN

AIR CURTAIN

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

DX MINI SPLIT - INSIDE

DX MINI SPLIT - OUTSIDE

UNIT HEATER

UNIT HEATER

UNIT HEATER

UNIT HEATER

GAS WATER HEAT & RECIRC PMP

GAS WATER HEAT & RECIRC PMP

BOOSTER PUMP

INSTANTANEOUS WATER HEATER

INSTANTANEOUS WATER HEATER

INSTANTANEOUS WATER HEATER

INSTANTANEOUS WATER HEATER

INSTANTANEOUS WATER HEATER

JOCKEY PUMP

FIRE PUMP

DISINTEGRATOR MAIN

DIS CYCLONE FAN MTR

DIS ROTARY AIRLOCK MTR

DIS FILTER SHAKER

DIS CONVEYOR

DOCK LEVELER

MOTORIZED GATE

EQUIPMENT

CONNECTION

LOCATION

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

ROOF

131 MECHANICAL

131 MECHANICAL

ROOF

ROOF

131 MECHANICAL

131 MECHANICAL

131 MECHANICAL

090 MCER

090 MCER

090 MCER

090 MCER

090 MCER

090 MCER

030 TR ROOM

ROOF

061 TR ROOM

ROOF

087 TR ROOM

093 SIPR TR

094 NIPR TR

120 TR ROOM

ROOF

136 ELECTRIC ROOM

ROOF

136 ELECTRIC ROOM

ROOF

063 TR ROOM

ROOF

090 MCER

007 WATER HEATER ROOM

098 WATER HEATER ROOM

149 ELECTRICAL ROOM

126 RECYCLE STORE ROOM

131 MECHANICAL ROOM

132 FIRE PUMP ROOM

149 ELECTRICAL ROOM

128 DISINTEGRATOR ROOM

136 ELECTRICAL ROOM

136 ELECTRICAL ROOM

118 CAGED STORAGE

160 SECURITY ACCESS FACILITY

SECURITY ACCESS FACILITY ROOF

031 ELECTRICAL ROOM

ROOF

062 ELECTRICAL ROOM

ROOF

086 ELECTRICAL ROOM

ROOF

115 ELECTRICAL ROOM

ROOF

121 ELECTRICAL ROOM

ROOF

149 ELECTRICAL ROOM

ROOF

001A VESTIBULE

ROOF

091 ESS ROOM

ROOF

141 TR ROOM

ROOF

097, 99, 100 LATRINES

126, 128 STORE, DIS

131 MECHANICAL

132 FIRE PUMP

007 WATER HEATER RM

098 WATER HEATER RM

131 MECHANICAL

142 TOILET

143A BREAK ROOM

150 TOILET

148 WORK ROOM

153 WORK ROOM

132 FIRE PUMP

132 FIRE PUMP

128 DISINTEGRATOR

128 DISINTEGRATOR

128 DISINTEGRATOR

128 DISINTEGRATOR

128 DISINTEGRATOR

LOADING DOCK

SITE

DRAWING

EP115

EP115

EP116

EP116

EP115

EP115

EP117

EP115

EP117

EP115

EP116

EP115

EP117

EP407

EP407

EP115

EP115

EP407

EP407

EP407

EP109

EP109

EP109

EP109

EP109

EP109

EP101

EP115

EP107

EP117

EP109

EP109

EP109

EP113

EP116

EP112

EP115

EP112

EP115

EP107

EP117

EP109

EP102

EP111

EP401

EP112

EP402

EP402

EP401

EP502

EP401

EP401

EP112

EP402

EP402

EP101

EP115

EP107

EP117

EP109

EP115

EP111

EP116

EP113

EP116

EP106

EP115

EP102

EP115

EP109

EP115

EP110

EP115

EP111

EP112

EP407

EP112

EP403

EP404

EP407

EP110

EP110

EP106

EP106

EP106

EP407

EP407

EP502

EP502

EP502

EP502

EP502

EP114

LOAD

7.5 HP

7.5 HP

1 HP

1 HP

1/4 HP

1/6 HP

3/4HP

1/6 HP

1/6 HP

1/2 HP

5 HP

1/6 HP

3 AT 1/2 HP

3 AT 1/15 HP

2 AT 1/15 HP

3 KW

3 KW

2 AT 1/6 HP

2 AT 1/6 HP

7.5 HP

4.1 KW

8 KW

4.1 KW

8 KW

8 KW

1.5 HP

60 HP

75 HP

7.5 HP

1 HP

.5 HP

1 HP

1 HP

1 HP

VOLT

PHASE

FLA

8.7

8.7

8.7

8.7

8.7

8.7

9.3

1.7

12.6

3.4

1.6

1.6

1.6

9.3

1.7

25.3

5.1

25.3

5.1

25.3

5.1

1.6

2.1

2.1

5.8

4.4

7.6

4.4

4.4

9.8

7.6

4.4

10.5

8.8

8.8

14.5

14.5

6.9

2.1

9.8

8.8

4.6

4.6

MCA

9.5

9.5

9.5

9.5

9.5

9.5

11.2

2.2

15.4

3.9

2.1

2.1

2.1

11.2

2.2

30.7

5.6

30.7

5.6

30.7

5.6

2.1

2.6

2.6

7.3

5.5

9.5

5.5

5.5

12.3

9.5

5.5

11.4

9.9

9.9

8.6

5.8

5.8

MOCP

SHORT

CIRCUIT

CURRENT

AVAILABLE

10K

10K

10K

10K

14K

14K

14K

14K

14K

14K

14K

14K

5K

5K

5K

14K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K 5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

5K

42K

10K

5K

5K

5K

5K

5K

5K

BRANCH CIRCUIT (CU)

3-#6 AWG & 1-#10 AWG GND IN 3/4" CND

3-#8 AWG & 1-#10 AWG GND IN 3/4" CND

3-#6 AWG & 1-#10 AWG GND IN 3/4" CND

3-#8 AWG & 1-#10 AWG GND IN 3/4" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#1/0 AWG & 1-#6 AWG GND IN 1-1/2" CND

2-#10 AWG & 1-#10 AWG GND IN 1/2" CND

2-#10 AWG & 1-#10 AWG GND IN 1/2" CND

2-#10 AWG & 1-#10 AWG GND IN 1/2" CND

2-#10 AWG & 1-#10 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#10 AWG & 1-#10 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#8 AWG & 1-#10 AWG GND IN 3/4" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#8 AWG & 1-#10 AWG GND IN 3/4" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#8 AWG & 1-#10 AWG GND IN 3/4" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#10 AWG & 1-#10 AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#10 AWG & 1-#10 AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12 AWG & 1-#12 AWG GND IN 1/2" CND

2-#12 AWG & 1-#12 AWG GND IN 1/2" CND

2-#8 AWG & 1-#10 AWG GND IN 3/4" CND

2-#12 AWG & 1-#12 AWG GND IN 1/2" CND

2-#8 AWG & 1-#10 AWG GND IN 3/4" CND

2-#8 AWG & 1-#10 AWG GND IN 3/4" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#1 AWG & 1-#6 AWG GND IN 1-1/2" RGS

3-#1/0 AWG & 1-#6 AWG GND IN 1-1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

2-#12 AWG & 1-#12 AWG GND IN 1/2" CND

2-#12 AWG & 1-#12 AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

3-#12AWG & 1-#12AWG GND IN 1/2" CND

DISCONNECT

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(39)(17)

(9)

(9)

(5)(17)

(2)(17)

(8)

(8)

(8)

(10)

(10)

(10)

(10)

(10)

(10)

(10)

(11)(17)

(10)

(11)(17)

(10)

(10)

(10)

(10)

(11)(17)

(10)

(11)(17)

(10)

(11)(17)

(10)

(11)(17)

(10)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(12)(17)

(14)

(7)

(1)(17) (7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(7)

(1)(17)

(13)

(13)

(13)

(13)

(8)

(8)

(38)

(22)

(23)

(22)

(23)

(23)

(26)

(25)

(32)

(33)

(33)

(36)

(35)

CONTROLS

AND

OTHER

WIRING

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(17)(19)

(18)

(18)

(17)(20)

(40)

(16)

(16)(17)

(16)

(16)(17)

(16)

(16)(17)

(16)

(16)(17)

(16)

(16)(17)

(16)

(16)(17)

(29)

(29)

(27)

(27)

(28)

(27)

(27)

(31)

(29)

(27)

(21)

(15)

(15) (15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(15)

(34)

(34)

(34)

(37)

GENERAL NOTES.

1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS NAMEPLATE RATINGS AND

MANUFACTURER'S INSTRUCTIONS. VERIFY ELECTRICAL DATA PRIOR TO EQUIPMENT INSTALLATION

AND INFORM CONTRACTING OFFICER OF DISCREPENCIES BETWEEN THE CONNECTION TABLE AND

MANUFACTURER'S INSTRUCTIONS THAT AFFECT THE ELECTRICAL INSTALLATION.

2. WHEN THE EQUIPMENT NAMEPLATE INCLUDES A SHORT CIRCUIT CURRENT RATING (SCCR), THE

NAMEPLATE VALUE MUST BE HIGHER THAN THE VALUE SHOWN FOR THE ELECTRICAL SYSTEM AT

THE LOCATION OF EQUIPMENT INSTALLATION. EQUIPMENT WITH AN INSUFFICIENT SCCR AS

DETERMINED BY THE EQUIPMENT NAMEPLATE SHALL NOT BE INSTALLED. THIS SCCR REQUIREMENT

DOES NOT APPLY TO EQUIPMENT THAT DOES NOT INCLUDE A SCCR ON THE EQUIPMENT NAMEPLATE.

NOTES: (#)

(1) SAFETY SWITCH 30 A HEAVY DUTY, 2 POLE, NEMA 4X STAINLESS STEEL ENCLOSURE,

NON-FUSED TWO GROUND LUGS, LOCK OFF PROVISIONS, RAINTIGHT HUBS.

(2) SAFETY SWITCH 30 A HEAVY DUTY, 2 POLE, NEMA 4X STAINLESS STEEL ENCLOSURE,

FUSED CLASS RK5 (30A), TWO GROUND LUGS, LOCK OFF PROVISIONS, RAINTIGHT HUBS.

(3) SAFETY SWITCH 60 A HEAVY DUTY, 3 POLE, NEMA 4X STAINLESS STEEL ENCLOSURE,

NON-FUSED TWO GROUND LUGS, LOCK OFF PROVISIONS, RAINTIGHT HUBS.

(4) SAFETY SWITCH 100 A HEAVY DUTY, 3 POLE, NEMA 4X STAINLESS STEEL ENCLOSURE,

NON-FUSED TWO GROUND LUGS, LOCK OFF PROVISIONS, RAINTIGHT HUBS.

(5) SAFETY SWITCH 200 A HEAVY DUTY, 3 POLE, NEMA 4X STAINLESS STEEL ENCLOSURE,

FUSED CLASS RK5 (200A), TWO GROUND LUGS, LOCK OFF PROVISIONS, RAINTIGHT HUBS.

(6) SAFETY SWITCH 30 A HEAVY DUTY, 3 POLE, NEMA 1 ENCLOSURE, CLASS RK5 FUSES,

TWO GROUND LUGS, LOCK OFF PROVISIONS.

(7) SAFETY SWITCH 30 A, GENERAL DUTY, 3 POLE, NEMA 1 ENCLOSURE, NON-FUSED,

TWO GROUND LUGS, LOCK OFF PROVISIONS.

(8) SAFETY SWITCH 30 A, GENERAL DUTY,1 POLE, SOLID NEUTRAL, NEMA 1 ENCLOSURE

NON FUSED, TWO GROUND LUGS, LOCK OFF PROVISIONS.

(9) DISCONNECT INTEGRAL WITH VFD.

(10) DISCONNECT PROVIDED INTEGRAL WITH CRAC UNIT.

(11) DISCONNECT PROVIDED INTEGRAL WITH ACC UNIT.

(12) DISCONNECT INTEGRAL WITH EXHAUST FAN AND CONTROLLER LOCKABLE.

(13) DISCONNECT INTEGRAL WITH UNIT HEATER.

(14) DISCONNECT INTEGRAL WITH AIR CURTAIN.

(15) INDOOR UNIT IS POWERED FROM OUTDOOR UNIT. FOLLOW MANUFACTURER'S

INSTRUCTIONS FOR WIRING BETWEEN INSIDE AND OUTSIDE UNIT. POWER WIRING TO CU AND

WIRING TO SS CAN SHARE COMMON CONDUIT PENETRATING ROOF.

(16) PROVIDE EMPTY 3/4" CONDUIT BETWEEN INDOOR AND OUTDOOR UNIT FOR CONTROL

WIRING. PATH WITH ELECTRICAL POWER CONDUIT.

(17) COORDINATE ROOF PENETRATION DETAIL WITH ROOFING CONTRACTOR

(18) VARIABLE SPEED DRIVE.

(19) PROVIDE 1" EMPTY RGS CONDUIT FROM RTU CONTROL PANEL TO BELOW ROOF DECK FOR

USE BY CONTRACTOR PROVIDING CONTROL WORK. PATH WITH ELECTRICAL POWER CONDUIT.

(20) PROVIDE 1" EMPTY RGS CONDUIT FROM CHILLER CONTROL PANEL TO BELOW ROOF DECK

FOR USE BY CONTRACTOR PROVIDING CONTROL WORK. PATH WITH ELECTRICAL POWER CONDUIT.

(21) DOOR SWITCH FURNISHED WITH UNIT FOLLOW MANUFACTURER'S INSTRUCTIONS FOR WIRING.

(22) SAFETY SWITCH 30 A GENERAL DUTY, 1 POLE, SOLID NEUTRAL, NEMA 1 ENCLOSURE,

NON FUSED, TWO GROUND LUGS, LOCK OFF PROVISIONS.

(23) SAFETY SWITCH 60 A GENERAL DUTY, 1 POLE, SOLID NEUTRAL, NEMA 1 ENCLOSURE,

NON FUSED, TWO GROUND LUGS, LOCK OFF PROVISIONS.

(24) SAFETY SWITCH 200 A GENERAL DUTY, 3 POLE, NEMA 1 ENCLOSURE, FUSED CLASS RK5, TWO GROUND LUGS, LOCK OFF PROVISIONS,

(25) DISCONNECT IS INTEGRAL TO FIRE PUMP CONTROLLER

(26) DISCONNECT IS INTEGRAL TO JOCKEY PUMP CONTROLLER

(27) COMBINATION MAGNETIC MOTOR STARTER, FVNR, FUSED RK5, 2 POLE, NEMA SIZE 0,

NEMA ENCLOSURE TYPE 1, 120 V COIL, OVERLOADS WITH MANUAL RESET, 2 EXTRA N.O. AUX

CONTACT, RED LED RUN PILOT LIGHT, PAD LOCKABLE, INCLUDE GROUND LUGS, HOA SWITCH

IN ENCLOSURE COVER. THREE WIRE CONTROL.

(28) COMBINATION MAGNETIC MOTOR STARTER, FVNR, FUSED RK5, 2 POLE, NEMA SIZE 0,

NEMA ENCLOSURE TYPE 1, 208 V COIL, OVERLOADS WITH MANUAL RESET, 2 EXTRA N.O. AUX

CONTACT, RED LED RUN PILOT LIGHT, PAD LOCKABLE, INCLUDE GROUND LUGS, HOA SWITCH

IN ENCLOSURE COVER. TWO WIRE CONTROL.

(29) COMBINATION MAGNETIC MOTOR STARTER, FVNR, FUSED RK5, 3 POLE, NEMA SIZE 1,

NEMA ENCLOSURE TYPE 1, 100VA EXTRA CAPACITY CONTROL XFMR WITH TWO PRIMARY AND ONE

SECONDARY FUSE, 120 V COIL, ELECTRONIC OVERLOADS CLASS 10 MANUAL RESET, 2 EXTRA

N.O. AUX CONTACTS, RED LED RUN PILOT LIGHTWITH OPERATING INTERLOCK, PAD LOCKABLE, INCLUDE GROUND LUGS, HOA IN ENCLOSURE COVER. TWO WIRE CONTROL.

(30) COMBINATION MAGNETIC MOTOR STARTER, FVNR, FUSED RK5, 3 POLE, NEMA SIZE 1,

NEMA ENCLOSURE TYPE 1, 100VA EXTRA CAPACITY CONTROL XFMR WITH TWO PRIMARY AND ONE

SECONDARY FUSE, 120 V COIL, ELECTRONIC OVERLOADS CLASS 10 MANUAL RESET, 2 EXTRA

N.O. AUX CONTACTS, RED LED RUN PILOT LIGHT WITH OPERATING INTERLOCK, GREEN LED

POWER AVAILABLE, PAD LOCKABLE, INCLUDE GROUND LUGS, HOA SWITCH IN ENCLOSURE COVER.

TWO WIRE CONTROL.

(31) COMBINATION MAGNETIC MOTOR STARTER, FVNR, FUSED RK5, 2 POLE, NEMA SIZE 0,

NEMA ENCLOSURE TYPE 1, 120 V COIL, OVERLOADS WITH MANUAL RESET, 2 EXTRA N.O. AUX

CONTACT, RED LED RUN PILOT LIGHT, PAD LOCKABLE, INCLUDE GROUND LUGS, START AND STOP

PUSHBUTTON SWITCHES IN ENCLOSURE COVER. THREE WIRE CONTROL.

(32) RELOCATED SAFETY SWITCH 200 A HEAVY DUTY, 3 POLE, NEMA 1 ENCLOSURE, CLASS RK5

FUSES, LOCK OFF PROVISIONS.

(33) SAFETY SWITCH 30 A HEAVY DUTY, 3 POLE, NEMA 1 ENCLOSURE, CLASS RK5 FUSES,

TWO GROUND LUGS, LOCK OFF PROVISIONS.

(34) RELOCATED MOTOR STARTER.

(35) RELOCATED MANUAL MOTOR STARTER.

(36) RELOCATED START STOP SWITCH

(37) RELOCATED MOTOR MASTER 20000, MINARIK CORP.

(38) DISCONNECT IS INTEGRAL TO BOOSTER PUMP SKID UNIT.

(39) DISCONNECT IS INTEGRAL TO ROOF TOP UNIT.

(40) HEAT TRACE CONTROLS INTEGRAL WITH CHILLER CONTROL PACKAGE.

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d E c w h e e le r.

rv t /2

/2

:4

:5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d E c w h e e le r.

rv t

/2

/2

:4

:5

P

M

P N

F

Y

/2

/2

EP601

M E

C H

A N

IC

A

L C

O N

N E

C T

IO

N

S C

H E

D U

L E

S P

S

R G

B

R K

R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

CKT.

NO.

TOTAL AMPS (CONN. LOAD)

TOTAL AMPS (FEEDTHRU)

TOTAL AMPS (CONN. LOAD + FEED-THRU)

PANELBOARD OPTIONS:

1.

2.

LOAD DESCRIPTION

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

SPARE

SPARE

SPARE

SPARE

SPARE

PROVIDE INTERNALLY MOUNTED SPD.

PROVIDE ISOLATED COMPARTMENT MINIMUM 8 INCHES HIGH HINGED

DOOR THAT ADVANCED METERING COMPONENTS CAN BE MOUNTED. SEE

SEE SHEET EP704.

WIRE

SIZE

3/0

3/0

3/0

3/0

3/0

3/0

BKR

TRIP

A:

A:

A:

AMPS

60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0

720.0

720.0

KVA

7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2

SWBD TOC PAD SCHEDULE

1200 AMP BUS 1200 AMP MCB 208Y/120 VOLTS 3PH, 4W, 60 HZ MIN. 22 KAIC FLOOR MOUNTED SE RATED NEMA 4X

PH

A

B C

A B

C A

B C

A B

C A

B C

A B

C A

B C

A B

C A

B C

B:

B:

B:

PANELBOARD NOTES:

1.

2.

KVA

7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2 7.2

720.0

720.0

LOCATION: EXTERIOR TOC PAD

MANUFACTURER MAY ADJUST BREAKER AND WIRE SIZE PER MANUFACTURER'S

STANDARD PRODUCT OFFERING.

AMPS

60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0

BKR

TRIP

C:

C:

C:

WIRE

SIZE

3/0

3/0

3/0

3/0

3/0

3/0

720.0

720.0

LOAD DESCRIPTION

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

200A TOC DISCONNECT

SPARE

SPARE

INTERNAL SURGE PROTECTION DEVICE

(SPD) (NOTE 2)

CKT.

NO.

COMPARTMENT DESCRIPTION

LOAD SERVED

INCOMING CABLE COMPARTMENT

MAIN CIRCUIT BREAKER

CUSTOMER METERING COMPARTMENT

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

TOTAL CONNECTED AMPS

SWBD MDH

SECTION 04

PANEL EDH

SECTION 04

SPARE

SECTION…

This is the start of the file's text. The full file is on GovTribe.