B3_170127_Corrected_Final_100__Submittal_Specs_Vol_II_of_III_5650.pdf

PDF 3 MB Posted

Attached to
MISSION TRAINING CENTER (MTC) SIMULATION CENTER AT FORT HOOD, TEXAS
Solicitation number
W9126G-17-R-0008
Issued by

About this file

B3 170127 Corrected Final 100% Submittal Specs Vol II of III_5650

View the file

Other files

File Type Posted
B3_g17r0008_am_6.pdf PDF
B3_g17r0008_am_5.pdf PDF
B3_g17r0008am_4.pdf PDF
B3_g17r0008_am_3.pdf PDF
MTC_Site_Visit_Sign_In_Sheet-20170210.pdf PDF
B3_17r0008_am_2.pdf PDF
VOLUME_2-_2_of_4.pdf PDF
VOLUME_2-_4_of_4.pdf PDF
VOLUME_2-_3_of_4.pdf PDF
VOLUME_2-_1_of_4.pdf PDF
VOLUME_1-_3_of_3.pdf PDF
VOLUME_1-_2_of_3.pdf PDF
VOLUME_1_-_1_of_3.pdf PDF
B3_g17r0008_am_1.pdf PDF
B3_g17r0008_Specs_Vol_I_of_III_(1).pdf PDF
B3_170127_Corrected_Final_100__Submittal_Specs_Vol_III_of_III_5650.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

I

US Army Corps Of Engineers Fort Worth District

SPECIFICATIONS

VOLUME II OF III

CORRECTED FINAL 100% SUBMITTAL

January 27, 2017

Contract No: W912HP-12-D-0002 Project: PN 68826 Mission Training Complex (MTC) Fort Hood, Texas

Simulations Center, Mission Training Complex (MTC) 5650

PROJECT TABLE OF CONTENTS – VOLUME II OF III Page 1

PROJECT TABLE OF CONTENTS

VOLUME II OF III

DIVISION 09 – FINISHES

09 22 00 SUPPORTS FOR GYPSUM BOARD

09 29 00 GYPSUM BOARD

09 30 13 CERAMIC TILING

09 51 00 ACOUSTICAL CEILINGS

09 51 01 ACOUSTICAL WOOD PANELS

09 65 00 RESILIENT FLOORING

09 66 23 RESINOUS TERRAZZO FLOORING

09 67 23.13 STANDARD RESINOUS FLOORING

09 68 00 CARPETING

09 90 00 PAINTS AND COATINGS

DIVISION 10 – SPECIALTIES

10 10 00 VISUAL COMMUNICATIONS SPECIALTIES

10 14 00.20 SIGNAGE

10 21 13 TOILET COMPARTMENTS

10 22 13 WIRE MESH PARTITIONS

10 22 39 FOLDING PANEL PARTITIONS

10 26 13 WALL AND CORNER GUARDS

10 28 13 TOILET ACCESSORIES

10 44 16 FIRE EXTINGUISHERS

10 51 13 METAL MINI LOCKERS

10 56 13 STEEL SHELVING

DIVISION 11 – EQUIPMENT

11 13 10 DOCK LEVELERS

DIVISION 12 – FURNISHINGS

12 24 13 ROLLER WINDOW SHADES

12 48 13 ENTRANCE FLOOR MATS AND FRAMES

12 65 00 FIXED LECTURE TABLE SYSTEM

12 93 00 SITE FURNISHINGS

DIVISION 21 - FIRE SUPPRESSION

21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION

21 13 18.00 10 PREACTION SPRINKLER SYSTEMS, FIRE PROTECTION

21 30 00 FIRE PUMPS

PROJECT TABLE OF CONTENTS – VOLUME II OF III Page 2

DIVISION 22 – PLUMBING

22 00 00 PLUMBING, GENERAL PURPOSE

22 11 16.11 AMERICAN WATER, WATER SERVICE TAPS AND SERVICE

LINE INSTALLATION

22 11 25.00 44 VIDEO INSPECTION OF PIPING (PROVIDED BY GOVERNMENT)

DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND

EXHAUST SYSTEMS

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 08 00.00 10 COMMISSIONING OF HVAC SYSTEMS

23 09 23 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND

OTHER BUILDING CONTROL SYSTEMS

23 11 25 FACILITY GAS PIPING

23 23 00 REFRIGERANT PIPING

23 52 00 HEATING BOILERS

23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE

23 64 26 CHILLED WATER PIPING SYSTEMS

23 81 23.00 20 COMPUTER ROOM AIR CONDITIONING UNITS

23 82 00.00 20 TERMINAL HEATING UNITS

23 82 02.00 10 UNITARY HEATING AND COOLING EQUIPMENT

DIVISION 25 - INTEGRATED AUTOMATION

25 08 10 UTILITY MONITORING AND CONTROL SYSTEM TESTING

25 10 10 UTILITY MONITORING AND CONTROL SYSTEM (UMCS)

FRONT END AND INTEGRATION

-- End of Project Table of Contents – VOLUME II OF III -

SECTION 09 22 00

SUPPORTS FOR GYPSUM BOARD

02/10

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A370 (2014) Standard Test Methods and Definitions for Mechanical Testing of Steel Products

ASTM A463/A463M (2010) Standard Specification for Steel Sheet, Aluminum-Coated, by the Hot-Dip Process

ASTM A653/A653M (2013) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

ASTM C645 (2014) Nonstructural Steel Framing Members

ASTM C754 (2015) Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products

ASTM E329 (2014a) Standard Specification for Agencies Engaged in the Testing and/or Inspection of Materials Used in Construction

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED (2009) LEED NC Reference Guide for Green Building Design and Construction

1.2 SUSTAINABLE DESIGN REQUIREMENTS

1.2.1 Recycled Content Materials

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total recycled material requirements. Submit manufacturer's descriptive data.

Documentation shall indicate percentage of postconsumer and preconsumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in the project.

1.2.2 Local/Regional Content Materials

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total

SECTION 09 22 00 Page 1 local/regional material requirements. Documentation shall indicate percentage of local/regional content per unit of product. Indicate relative dollar value of regional content products to total dollar value of products included in the project.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Metal support systems; G

Submit for the erection of metal wall framing, furring, and ceiling suspension systems. Indicate materials, sizes, thicknesses, and fastenings.

SD-03 Product Data

Recycled Content Materials ( LEED); G, S

Local/Regional Content Materials ( LEED); G, S

SD-05 Design Data

Metal Framing Calculations; G

SD-07 Certificates

Non-Load Bearing Metal Framing

SD-11 Closeout Submittals

Recycled Content Materials ( LEED); G, S

Local/Regional Content Materials ( LEED); G, S

1.4 DELIVERY, STORAGE, AND HANDLING

Deliver materials to the job site and store in ventilated dry locations.

Storage area shall permit easy access for inspection and handling. If materials are stored outdoors, stack materials off the ground, supported on a level platform, and fully protected from the weather. Handle materials carefully to prevent damage. Remove damaged items and provide new items.

1.5 NON-LOAD BEARING METAL FRAMING

Include top and bottom tracks, bracing, fastenings, and other accessories necessary for complete installation. Framing members shall be as necessary to withstand all imposed loads. Submit mill certificates to test reports from independent testing agency, qualified in accordance with ASTM E329, showing that the steel sheet used in the manufacturer of each

SECTION 09 22 00 Page 2 competent complies with the minimum yield strengths and uncoated steel thickness specified. Test reports shall be based on the results of three coupon tests in accordance with ASTM A370.

1.6 QUALITY ASSURANCE

Engineering Responsibility: Preparation of Shop Drawings, design calculations, and other structural data by a registered professional engineer.

Sign and seal fabrication drawings by a registered professional engineer.

1.7 Design Data Required

Submit metal framing calculations with design criteria and structural loading to verify sizes, thickness, and spacing of members and connections signed and sealed by a registered professional engineer. Show methods and practices used in installation.

PART 2 PRODUCTS

2.1 MATERIALS

Provide steel materials for metal support systems with galvanized coating ASTM A653/A653M , G-60; aluminum coating ASTM A463/A463M , T1-25; or a 55-percent aluminum-zinc coating. Provide support systems and attachments per UFC 3-310-04, "Seismic Design for Buildings" in seismic zones.

2.1.1 Materials for Attachment of Gypsum Wallboard

2.1.1.1 Suspended and Furred Ceiling Systems

ASTM C645.

2.1.1.2 Nonload-Bearing Wall Framing and Furring

ASTM C645, but not thinner than thickness determined by calculations for depth of studs as indicated. Flange width and stud gauge and stud spacing may vary; stud depth as indicated shall not vary. Stud spacing shall be 16 inches on center, minimum. The ASTM certified third party testing statement for equivalent thicknesses shall not apply.

2.1.1.3 Furring Channels with or without Wall Insulation

Not lighter than 26 gage galvanized steel, Z-shaped, or C-shaped with 1-1/4 inch and 3/4 inch flanges and furring depth as indicated.

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Systems for Attachment of Gypsum Wallboard

3.1.1.1 Suspended and Furred Ceiling Systems

ASTM C754, except provide framing members 16 inches o.c. minimum, unless a closer spacing is required.

SECTION 09 22 00 Page 3

3.1.1.2 Non-loadbearing Wall Framing and Furring

ASTM C754, except as indicated otherwise.

3.1.1.3 Furring Channels with Wall Insulation

Install furring channels vertically spaced not more than 16 inches o.c.

Locate furring channels at interior and exterior corners in accordance with manufacturer's printed erection instructions.

3.2 ERECTION TOLERANCES

Provide framing members which will be covered by finish materials such as wallboard, plaster, or ceramic tile set in a mortar setting bed, within the following limits:

a. Layout of walls and partitions: 1/4 inch from intended position;

b. Plates and runners: 1/4 inch in 8 feet from a straight line;

c. Studs: 1/4 inch in 8 feet out of plumb, not cumulative; and

d. Face of framing members: 1/4 inch in 8 feet from a true plane.

Provide framing members which will be covered by ceramic tile within the following limits:

a. Layout of walls and partitions: 1/4 inch from intended position;

b. Plates and runners: 1/8 inch in 8 feet from a straight line;

c. Studs: 1/8 inch in 8 feet out of plumb, not cumulative; and

d. Face of framing members: 1/8 inch in 8 feet from a true plane.

-- End of Section --

SECTION 09 22 00 Page 4

SECTION 09 29 00

GYPSUM BOARD

05/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A108.11 (1992; Reaffirmed 2005) Specifications for Interior Installation of Cementitious Backer Units

ASTM INTERNATIONAL (ASTM)

ASTM C1002 (2014) Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs

ASTM C1047 (2014a) Standard Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base

ASTM C1177/C1177M (2013) Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing

ASTM C1396/C1396M (2014a) Standard Specification for Gypsum Board

ASTM C475/C475M (2012; E 2014) Joint Compound and Joint Tape for Finishing Gypsum Board

ASTM C840 (2013) Application and Finishing of Gypsum Board

ASTM C954 (2011) Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from

0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness

ASTM D1149 (2007; R 2012) Standard Test Method for Rubber Deterioration - Surface Ozone Cracking in a Chamber

ASTM D226/D226M (2009) Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing

ASTM D412 (2006a; R 2013) Standard Test Methods for

SECTION 09 29 00 Page 1

Vulcanized Rubber and Thermoplastic Elastomers - Tension

ASTM D624 (2000; R 2012) Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers

ASTM E2129 (2010) Standard Practice for Data Collection for Sustainability Assessment of Building Products

GYPSUM ASSOCIATION (GA)

GA 214 (2010) Recommended Levels of Gypsum Board Finish

GA 216 (2010) Application and Finishing of Gypsum Panel Products

GA 253 (2012) Application of Gypsum Sheathing

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS Scientific Certification Systems (SCS)Indoor Advantage

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED (2009) LEED NC Reference Guide for Green Building Design and Construction

UL ENVIRONMENT (ULE)

ULE Greenguard UL Greenguard Certification Program

UNDERWRITERS LABORATORIES (UL)

UL Fire Resistance (2014) Fire Resistance Directory

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Recycled Content Materials ( LEED); G, S

Local/Regional Content Materials ( LEED); G, S

Low Emitting Materials-Adhesives and Sealants ( LEED); G, S

Cementitious backer units

SECTION 09 29 00 Page 2

Water-Resistant Gypsum Backing Board

Glass Mat Covered or Reinforced Gypsum Sheathing

Glass Mat Covered or Reinforced Gypsum Sheathing Sealant

Accessories

Submit for each type of gypsum board and for cementitious backer units.

Certification

Gypsum Board

Submit documentation indicating percentage of post-industrial and post-consumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in project.

Adhesives Joint Treatment Materials

Submit manufacturer's product data, indicating VOC content.

Environmental Data

SD-11 Closeout Submittals

Recycled Content Materials ( LEED); G, S Local/Regional Content Materials ( LEED); G, S Low Emitting Materials-Adhesives and Sealants ( LEED); G, S LEED documentation relative to local/regional materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.

Gypsum Board; (LEED)

LEED documentation relative to recycled content credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.

Adhesives; (LEED)

LEED documentation relative to low emitting materials credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.

1.3 SUSTAINABLE DESIGN CERTIFICATION

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total material requirements.

Product shall be third party certified in accordance with ULE Greenguard , SCS Scientific Certification Systems Indoor Advantage or equal.

Certification shall be performed annually and shall be current.

SECTION 09 29 00 Page 3

1.4 DELIVERY, STORAGE, AND HANDLING

1.4.1 Delivery

Deliver materials in the original packages, containers, or bundles with each bearing the brand name, applicable standard designation, and name of manufacturer, or supplier.

1.4.2 Storage

Keep materials dry by storing inside a sheltered building. Where necessary to store gypsum board and cementitious backer units outside, store off the ground, properly supported on a level platform, and protected from direct exposure to rain, snow, sunlight, and other extreme weather conditions. Provide adequate ventilation to prevent condensation. Store per manufacturer's recommendations for allowable temperature and humidity range. Gypsum wallboard shall not be stored with materials which have high emissions of volatile organic compounds (VOCs) or other contaminants. Do not store panels near materials that may offgas or emit harmful fumes, such as kerosene heaters, fresh paint, or adhesives.

1.4.3 Handling

Neatly stack gypsum board and cementitious backer units flat to prevent sagging or damage to the edges, ends, and surfaces.

1.5 ENVIRONMENTAL CONDITIONS

1.5.1 Temperature

Maintain a uniform temperature of not less than 50 degrees F in the structure for at least 48 hours prior to, during, and following the application of gypsum board, cementitious backer units, and joint treatment materials, or the bonding of adhesives.

1.5.2 Exposure to Weather

Protect gypsum board and cementitious backer unit products from direct exposure to rain, snow, sunlight, and other extreme weather conditions.

1.5.3 Temporary Ventilation

Provide temporary ventilation for work of this section.

1.6 SUSTAINABLE DESIGN REQUIREMENTS

1.6.1 Recycled Content Materials

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total recycled material requirements. Submit manufacturer's descriptive data.

Documentation shall indicate percentage of postconsumer and preconsumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in the project.

1.6.2 Local/Regional Content Materials

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total

SECTION 09 29 00 Page 4 percentage of local/regional content per unit of product. Indicate relative dollar value of regional content products to total dollar value of products included in the project.

1.6.3 Low Emitting Materials-Adhesives and Sealants

See Section 01 33 29 SUSTAINABILITY REPORTING for requirements. Submit manufacturer's documentation that adhesives and sealants are in compliance.

1.6.4 Environmental Data

Submit Table 1 of ASTM E2129 for products in this section requiring LEED documentation.

1.7 QUALIFICATIONS

Furnish type of gypsum board work specialized by the installer with a minimum of 3 years of documented successful experience.

1.8 SCHEDULING

The gypsum wallboard shall be taped, spackled and primed before the installation of the highly-emitting materials.

PART 2 PRODUCTS

2.1 MATERIALS

Conform to specifications, standards and requirements specified. Provide gypsum board types, gypsum backing board types, cementitious backing units, and joint treating materials manufactured from asbestos free materials only. Submit Material Safety Data Sheets and manufacturer maintenance instructionsfor gypsum materials including adhesives.

2.1.1 Gypsum Board

ASTM C1396/C1396M . See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total recycled content requirements. Gypsum board may contain post-consumer or post-industrial recycled content.

2.1.1.1 Regular

48 inch wide, 1/4 inch thick, tapered edges. Provide for curved wall construction.

2.1.1.2 Foil-Backed

48 inch wide, 5/8 inch thick, tapered edges.

2.1.1.3 Type X (Special Fire-Resistant)

48 inch wide, 5/8 inch thick, tapered edges.

2.1.2 Gypsum Backing Board

ASTM C1396/C1396M , gypsum backing board shall be used as a base in a multilayer system.

SECTION 09 29 00 Page 5

2.1.2.1 Regular

48 inch wide, 1/4 inch thick, square edges. Provide as base layer for curved wall construction.

2.1.2.2 Foil-Backed

48 inch wide, 5/8 inch thick, square edges.

2.1.2.3 Type X (Special Fire-Resistant)

48 inch wide, 5/8 inch thick, square edges.

2.1.3 Regular Water-Resistant Gypsum Backing Board

ASTM C1396/C1396M .

2.1.3.1 Type X (Special Fire-Resistant)

48 inch wide, 5/8 inch thick, tapered edges.

2.1.4 Glass Mat Covered or Reinforced Gypsum Sheathing

Exceeds physical properties of ASTM C1396/C1396M and ASTM C1177/C1177M .

Provide 5/8 inch, gypsum sheathing. Provide gypsum board of with a noncombustible water-resistant core, with glass mat surfaces embedded to the gypsum core or reinforcing embedded throughout the gypsum core.

Warrant gypsum sheathing board for at least twelve months against delamination due to direct weather exposure. Provide continuous, asphalt impregnated, building felt to cover exterior face of sheathing. Seal all joints, seams, and penetrations with compatible sealant.

2.1.4.1 Glass Mat Covered or Reinforced Gypsum Sheathing Sealant

Provide sealant compatible with gypsum sheathing, rubber washers for masonry veneer anchors, and other associated cavity wall components such as anchors and through wall flashing. Provide sealants for gypsum sheathing board edge seams and veneer anchor penetrations recommended by the gypsum sheathing manufacturer and have the following performance requirements:

a. ASTM D412: Tensile Strength, 80 psi

b. ASTM D412: Ultimate Tensile Strength (maximum elongation), 170 psi

c. ASTM D624: Tear Strength, dieB, 27 ppi

d. ASTM D1149: Joint Movement Capability after 14 Days cure, plus or minus 50 percent.

2.1.5 Cementitious Backer Units

In accordance with the Tile Council of America (TCA) Handbook.

2.1.6 Joint Treatment Materials

ASTM C475/C475M. Pre-mixed compounds shall be free of antifreeze, vinyl adhesives, preservatives, biocides and other slow releasing compounds.

2.1.6.1 Embedding Compound

Specifically formulated and manufactured for use in embedding tape at

SECTION 09 29 00 Page 6 gypsum board joints and compatible with tape, substrate and fasteners.

2.1.6.2 Finishing or Topping Compound

Specifically formulated and manufactured for use as a finishing compound.

2.1.6.3 All-Purpose Compound

Specifically formulated and manufactured to serve as both a taping and a finishing compound and compatible with tape, substrate and fasteners.

2.1.6.4 Setting or Hardening Type Compound

Specifically formulated and manufactured for use with fiber glass mesh tape.

2.1.6.5 Joint Tape

Use cross-laminated, tapered edge, reinforced paper, or fiber glass mesh tape recommended by the manufacturer.

2.1.7 Fasteners

2.1.7.1 Screws

ASTM C1002, Type "G", Type "S" or Type "W" steel drill screws for fastening gypsum board to gypsum board, wood framing members and steel framing members less than 0.033 inch thick. ASTM C954 steel drill screws for fastening gypsum board to steel framing members 0.033 to 0.112 inch thick. Provide cementitious backer unit screws with a polymer coating.

2.1.8 Adhesives

Do not use adhesive containing benzene, carbon tetrachloride, or trichloroethylene. Adhesive shall contain a maximum VOC content of 50 grams per liter. Adhesive must meet the requirements of LEED low emitting materials credit.

2.1.8.1 Adhesive for Laminating

Adhesive attachment for multi-layer gypsum boards: for laminating gypsum panels, provide adhesive recommended by gypsum board manufacturer.

2.1.9 Accessories

ASTM C1047. Fabricate from corrosion protected steel or plastic designed for intended use. Accessories manufactured with paper flanges are not acceptable. Flanges shall be free of dirt, grease, and other materials that may adversely affect bond of joint treatment. Provide prefinished or job decorated materials.

2.1.10 Asphalt Impregnated Building Felt

Provide a 30 lb asphalt moisture barrier over gypsum sheathing.

Conforming to ASTM D226/D226M Type 1 (No. 15) for asphalt impregnated building felt.

SECTION 09 29 00 Page 7

2.1.11 Water

Provide clean, fresh, and potable water.

PART 3 EXECUTION

3.1 EXAMINATION

3.1.1 Framing and Furring

Verify that framing and furring are securely attached and of sizes and spacing to provide a suitable substrate to receive gypsum board and cementitious backer units. Verify that all blocking, headers and supports are in place to support plumbing fixtures and to receive soap dishes, grab bars, towel racks, and similar items. Do not proceed with work until framing and furring are acceptable for application of gypsum board and cementitious backer units.

3.2 APPLICATION OF GYPSUM BOARD

Apply gypsum board to framing and furring members in accordance with ASTM C840 or GA 216 and the requirements specified. Apply gypsum board with separate panels in moderate contact; do not force in place. Stagger end joints of adjoining panels. Neatly fit abutting end and edge joints.

Use gypsum board of maximum practical length; select panel sizes to minimize waste. Cut out gypsum board to make neat, close, and tight joints around openings. In vertical application of gypsum board, provide panels in lengths required to reach full height of vertical surfaces in one continuous piece. Lay out panels to minimize waste; reuse cutoffs whenever feasible. Treat edges of cutouts for plumbing pipes, screwheads, and joints with water-resistant compound as recommended by the gypsum board manufacturer. Provide type of gypsum board for use in each system specified herein as indicated.

3.2.1 Application of Gypsum Board to Steel Framing and Furring

Apply in accordance with ASTM C840, System VIII or GA 216 .

3.2.2 Arches and Bending Radii

Apply gypsum board in accordance with ASTM C840, System IX or GA 216 .

Provide laminated layers for radiuses partitions as indicated.

3.2.3 Gypsum Board for Wall Tile or Tile Base Applied with Adhesive

In dry areas (areas other than tubs, shower enclosures, saunas, steam rooms, gang shower rooms), apply glass mat water-resistant gypsum tile backing board in accordance with ASTM C840, System X or GA 216 .

3.2.4 Exterior Application

Apply exterior gypsum board (such as at soffits) in accordance with ASTM C840, System XI or GA 216 .

3.2.5 Glass Mat Covered or Fiber Reinforced Gypsum Sheathing

Apply gypsum sheathing in accordance to gypsum association publications GA 253 . Follow gypsum sheathing manufacturer's requirements of design details for joints and fasteners and be properly installed to protect the

SECTION 09 29 00 Page 8 substrate from moisture intrusion. Do not leave exposed surfaces of the gypsum sheathing beyond the manufacturer's recommendation without a weather barrier cladding. Provide continuous asphalt impregnated building felt over sheathing surface in shingle fashion with edges and ends lapped a minimum of 6 inch. Property flash the openings. Seal all joints, seams, and penetrations with a compatible silicone sealant.

3.2.6 Control Joints

Install expansion and contraction joints in ceilings and walls in accordance with ASTM C840, System XIII or GA 216 . Fill control joints between studs in fire-rated construction with firesafing insulation to match the fire-rating of construction.

3.2.7 Application of Foil-Backed Gypsum Board

Apply foil-backed gypsum board in accordance with ASTM C840, System XIV or

GA 216 .

3.3 APPLICATION OF CEMENTITIOUS BACKER UNITS

3.3.1 Application

In wet areas (tubs, shower enclosures, saunas, steam rooms, gang shower rooms), apply cementitious backer units in accordance with ANSI A108.11 .

Place a 15 lb asphalt impregnated, continuous felt paper membrane behind cementitious backer units, between backer units and studs or base layer of gypsum board. Place membrane with a minimum 6 inch overlap of sheets laid shingle style.

3.3.2 Joint Treatment

ANSI A108.11 .

3.4 FINISHING OF GYPSUM BOARD

Tape and finish gypsum board in accordance with ASTM C840, GA 214 and GA 216 . Finish plenum areas above ceilings to Level 1 in accordance with GA 214 . Finish water resistant gypsum backing board, ASTM C1396/C1396M , to receive ceramic tile to Level 2 in accordance with GA 214 . Finish walls and ceilings to receive a heavy-grade wall covering or heave textured finish before painting to Level 3 in accordance with GA 214 .

Finish walls and ceilings without critical lighting to receive flat paints, light textures, or wall coverings to Level 4 in accordance with GA 214 . Unless otherwise specified, finish all gypsum board walls, partitions and ceilings to Level 5 in accordance with GA 214 . Provide joint, fastener depression, and corner treatment. Tool joints as smoothly as possible to minimize sanding and dust. Do not use fiber glass mesh tape with conventional drying type joint compounds; use setting or hardening type compounds only. Provide treatment for water-resistant gypsum board as recommended by the gypsum board manufacturer. Protect workers, building occupants, and HVAC systems from gypsum dust.

3.4.1 Uniform Surface

Wherever gypsum board is to receive eggshell, semigloss or gloss paint finish, or where severe, up or down lighting conditions occur, finish gypsum wall surface in accordance to GA 214 Level 5. In accordance with GA 214 Level 5, apply a thin skim coat of joint compound to the entire

SECTION 09 29 00 Page 9 gypsum board surface, after the two-coat joint and fastener treatment is complete and dry.

3.5 SEALING

Seal openings around pipes, fixtures, and other items projecting through gypsum board and cementitious backer units as specified in Section 07 92 00 JOINT SEALANTS Apply material with exposed surface flush with gypsum board or cementitious backer units.

3.5.1 Sealing for Glass Mat or Reinforced Gypsum Board Sheathing

Apply silicone sealant in a 3/8 inch bead to all joints and trowel flat.

Apply enough of the same sealant to all fasteners penetrating through the glass mat gypsum board surface to completely cover the penetration when troweled flat. Do not place construction and materials behind sheathing until a visual inspection of sealed joints during daylight hours has been completed by Contracting Officer.

3.6 FIRE-RESISTANT ASSEMBLIES

Wherever fire-rated construction is indicated, provide materials and application methods, including types and spacing of fasteners, wall and ceiling framing in accordance with the specifications contained in UL Fire Resistance for the Design Number(s) indicated. Joints of fire-rated gypsum board enclosures shall be closed and sealed in accordance with UL test requirements or GA requirements. Seal penetrations through rated partitions and ceilings tight in accordance with tested systems.

3.7 PATCHING

Patch surface defects in gypsum board to a smooth, uniform appearance, ready to receive finishes.

3.8 WASTE MANAGEMENT

As specified in Waste Management Plan and as follows . Separate clean waste gypsum products from contaminants. Do not include wood, plastic, metal, asphalt-impregnated gypsum board, or any gypsum board coated with glass fiber, vinyl, decorative paper, or other finish. Place in designated area and protect from moisture and contamination.

If advantageous toward achieving the associated LEED credit: Identify manufacturer's policy for collection or return of remaining construction scrap, unused material, demolition scrap, and packaging material.

Institute demolition and construction recycling to take advantage of manufacturer's programs. When such a service is not available, seek local recyclers to reclaim the materials.

SECTION 09 29 00 Page 10

SECTION 09 30 13

CERAMIC TILING

11/13

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A118.10 Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installations

ANSI A137.1 (2012) American National Standards Specifications for Ceramic Tile

ASTM INTERNATIONAL (ASTM)

ASTM A1064/A1064M (2015) Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete

ASTM C1026 (2013) Standard Test Method for Measuring the Resistance of Ceramic Tile to Freeze-Thaw Cycling

ASTM C1193 (2013) Standard Guide for Use of Joint Sealants

ASTM C144 (2011) Standard Specification for Aggregate for Masonry Mortar

ASTM C150/C150M (2015) Standard Specification for Portland Cement

ASTM C206 (2014) Standard Specification for Finishing Hydrated Lime

ASTM C207 (2006; R 2011) Standard Specification for Hydrated Lime for Masonry Purposes

ASTM C241/C241M (2013) Standard Specification for Abrasion Resistance of Stone Subjected to Foot Traffic

ASTM C33/C33M (2013) Standard Specification for Concrete Aggregates

ASTM C373 (2014a) Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific

SECTION 09 30 13 Page 1

Gravity of Fired Whiteware Products

ASTM C627 (2010) Standard Test Method for Evaluating Ceramic Floor Tile Installation Systems Using the Robinson-Type Floor Tester

ASTM C648 (2004; R 2009) Breaking Strength of Ceramic Tile

ASTM C847 (2014a) Standard Specification for Metal Lath

MARBLE INSTITUTE OF AMERICA (MIA)

MIA Design Manual (2003) Dimension Stone Design Manual

TILE COUNCIL OF NORTH AMERICA (TCNA)

TCNA Hdbk (2013) Handbook for Ceramic, Glass, and Stone Tile Installation

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED (2009) LEED NC Reference Guide for Green Building Design and Construction

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Detail Drawings; G

SD-03 Product Data

Tile; G Setting-Bed; G Mortar, Grout, and Adhesive ; (LEED) ; G Reinforcing Wire Fabric; ( LEED) Recycled Content Materials; G, S Local/Regional Content Materials; G, S Low Emitting Material-Adhesives And Sealants; G, S Low Emitting Materials-Flooring Systems; G, S

SD-04 Samples

SECTION 09 30 13 Page 2

Tile; G Accessories; G Transition Strips; G Grout; G

SD-07 Certificates

Tile Mortar, Grout, and Adhesive

SD-08 Manufacturer's Instructions

Maintenance Instructions

SD-10 Operation and Maintenance Data

Installation; G

SD-11 Closeout Submittals

Adhesives; (LEED) Recycled Content Materials; G, S Local/Regional Content Materials; G, S Low Emitting Material-Adhesives And Sealants; G, S Low Emitting Materials-Flooring Systems; G, S

1.3 SUSTAINABLE DESIGN REQUIREMENTS

1.3.1 Recycled Content Materials

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total recycled material requirements. Submit manufacturer's descriptive data.

Documentation shall indicate percentage of postconsumer and preconsumer recycled content per unit of product. Indicate relative dollar value of recycled content products to total dollar value of products included in the project.

1.3.2 Local/Regional Content Materials

See Section 01 33 29 SUSTAINABILITY REPORTING for cumulative total local/regional material requirements. Documentation shall indicate percentage of local/regional content per unit of product. Indicate relative dollar value of regional content products to total dollar value of products included in the project.

1.3.3 Low Emitting Material-Adhesives and Sealants

See Section 01 33 29 SUSTAINABILITY REPORTING for requirements. Submit manufacturer's documentation that adhesives and sealants are in compliance.

1.3.4 Low Emitting Materials-Flooring Systems

See Section 01 33 29 SUSTAINABILITY REPORTING for requirements. Submit manufacturer's documentation that flooring systems are in compliance.

1.4 QUALITY ASSURANCE

Installers to be from a company specializing in performing this type of

SECTION 09 30 13 Page 3 work and have a minimum of two years experience. Each type and color of tile to be provided from a single source. Each type and color of mortar, adhesive, and grout to be provided from the same source.

1.5 DELIVERY, STORAGE, AND HANDLING

Ship tiles in sealed packages and clearly marked with the grade, type of tile, producer identification, and country of origin. Deliver materials to the project site in manufacturer's original unopened containers with seals unbroken and labels and hallmarks intact. Protect materials from weather, and store them under cover in accordance with manufacturer's printed instructions.

1.6 ENVIRONMENTAL REQUIREMENTS

Do not perform ceramic tile work unless the substrate and ambient temperature is at least 50 degrees F and rising. Maintain temperature above50 degrees F while the work is being performed and for at least 7 days after completion of the work. When temporary heaters are used, ventilate the area to the outside to avoid carbon dioxide damage to new tilework.

1.7 WARRANTY

Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1-year period.

1.8 EXTRA MATERIALS

Supply an extra 2 percent of each type tile used in clean and marked cartons.

PART 2 PRODUCTS

2.1 TILE

Furnish tiles that comply with ANSI A137.1 and are standard grade tiles.

Provide a minimum breaking strength of 125 lbs. for wall tile and 250 lbs.

for floor tile in accordance with ASTM C648. Provide exterior building tile for cold climate projects that is approved by the manufacturer for exterior use when tested in accordance with ASTM C1026. Provide floor tiles with a wet dynamic coefficient of friction (DCOF) value of 0.42 or greater when tested in accordance with ANSI A137.1 requirements. For materials like tile, accessories, and transition strips submit samples of sufficient size to show color range, pattern, type and joints. Submit manufacturer's catalog data.

2.1.1 Porcelain Tile

Furnish unglazed or glazed, rectified porcelain tile, base and trim pieces with color extending uniformly through the body of the tile. Provide tile with a V2 aesthetic classification. Blend tiles in factory and in a packages to have same color range and continuous blend for installation.

Provide nominal tile size(s) of 6 by 612 by 12 inch and 10.5 mm thick.

Provide a 20 percent maximum water absorption in accordance with ASTM C373.

2.1.2 Mosaic Tile

Furnish unglazed and glazed, mosaic tile and trim composed of porcelain.

SECTION 09 30 13 Page 4

Provide tile with a V2 aesthetic classification. Blend tiles in factory and in a packages to have same color range and continuous blend for installation. Provide a mixture of standard sizes in a stock pattern.

Provide porcelain mosaics with a water absorption up to 0.20 percent when tested in accordance with ASTM C373.

2.1.3 Accessories

Provide built-in type accessories of the same materials and finish as the wall tile. Provide accessories as follows:

Quantity Location

Recessed soap holders 2 Room 097 Shower's

Recessed soap holders 2 Room 100 Shower's

Recessed soap holders 3 Room 005 Shower's

Recessed soap holders 3 Room 009 Shower's

2.2 MISCELLANEOUS MATERIALS

Provide metal Brushed Nickel anodized aluminum edge strips, height to match tile and setting-bed thickness, designed specifically for tile application, outside corners use Schluter - ECK-E and Dilex - AHK, cove shaped profile for inside wall corners and floor/wall transitions.

2.3 SETTING-BED

Submit manufacturer's catalog data. Compose the setting-bed of the following materials:

2.3.1 Aggregate for Concrete Fill

Conform to ASTM C33/C33M for aggregate fill. Do not exceed one-half the thickness of concrete fill for maximum size of coarse aggregate.

2.3.2 Portland Cement

Conform to ASTM C150/C150M for cement, Type I, white for wall mortar and gray for other uses.

2.3.3 Sand

Conform to ASTM C144 for sand.

2.3.4 Hydrated Lime

Conform to ASTM C206 for hydrated lime, Type S or ASTM C207, Type S.

2.3.5 Metal Lath

Conform to ASTM C847 for flat expanded type metal lath, and weighing a minimum 2.5 pound/square yard.

SECTION 09 30 13 Page 5

2.3.6 Reinforcing Wire Fabric

Conform to ASTM A1064/A1064M for wire fabric. Provide 2 by 2 inch mesh.

2.4 WATER

Provide potable water.

2.5 MORTAR, GROUT, AND ADHESIVE

Submit certificates indicating conformance with specified requirements.

Submit LEED documentation relative to low-emitting materials credit in accordance with 01 33 29 SUSTAINABILITY REPORTING. Interior adhesives, sealants, primers and sealants used as filler must meet the requirements of LEED low emitting materials credit. Submit manufacturer's catalog data.

2.5.1 Latex-Portland Cement Mortar

TCNA Hdbk.

2.5.2 Ceramic Tile Grout (Walls)

TCNA Hdbk; petroleum-free and plastic-free latex-portland cement grout.

2.5.3 Epoxy Resin Grout (Floors and Showers)

TCNA Hdbk.

2.5.4 Sealants

Comply with applicable regulations regarding toxic and hazardous materials and as specified. Grout sealant must not change the color or alter the appearance of the grout.

2.5.5 Cementitious Backer Board

Provide cementitious backer units, for use as tile substrate over wood sub-floors, in accordance with TCNA Hdbk. Furnish 1/2inch thick cementitious backer units.

2.6 TRANSITION STRIPS

Provide marble transitions appropriate for conditions. Categorize marble Group A as classified by MIA Design Manual . Provide a fine sand-rubbed finish marble, beige in color. Provide minimum 12.0 marble abrasion when tested in accordance with ASTM C241/C241M. Provide transition strips that comply with 36 CFR 1191 requirements.

2.7 MEMBRANE MATERIALS

Conform to ANSI A118.10 for waterproofing membrane, ASTM C627 for heavy duty.

2.8 COLOR, TEXTURE, AND PATTERN

Provide color, pattern and texture as indicated. Color listed is not intended to limit the selection of equal colors from other manufacturers.

Provide floor patterns as specified on the drawings.

SECTION 09 30 13 Page 6

PART 3 EXECUTION

3.1 PREPARATORY WORK AND WORKMANSHIP

Inspect surface to receive tile in conformance to the requirements of TCNA Hdbk for surface conditions for the type setting bed specified and for workmanship. Provide variations of tiled surfaces that fall within maximum values shown below:

TYPE WALLS FLOORS

Dry-Set Mortar 1/8 inch in 8 ft. 1/8 inch in 10 ft.

Organic Adhesives 1/8 inch in 8 ft. 1/16 inch in 3 ft.

Latex Portland Cement Mortar 1/8 inch in 8 ft. 1/8 inch in 10 ft.

Epoxy 1/8 inch in 8 ft. 1/8 inch in 10 ft.

3.2 GENERAL INSTALLATION REQUIREMENTS

Do not start tile work until roughing in for mechanical and electrical work has been completed and tested, and built-in items requiring membrane waterproofing have been installed and tested. Close space, in which tile is being set, to traffic and other work. Keep closed until tile is firmly set. Do not start floor tile installation in spaces requiring wall tile until after wall tile has been installed. Apply tile in colors and patterns indicated in the area shown on the drawings. Install tile with the respective surfaces in true even planes to the elevations and grades shown. Provide special shapes as required for sills, jambs, recesses, offsets, external corners, and other conditions to provide a complete and neatly finished installation. Solidly back tile bases and coves with mortar. Do not walk or work on newly tiled floors without using kneeling boards or equivalent protection of the tiled surface. Keep traffic off horizontal portland cement mortar installations for at least 72 hours.

Keep all traffic off epoxy installed floors for at least 40 hours after grouting, and heavy traffic off for at least 7 days, unless otherwise specifically authorized by manufacturer. Dimension and draw detail drawingsat a minimum scale of 1/4 inch = 1 foot. Include drawings of pattern at inside corners, outside corners, termination points and location of all equipment items such as thermostats, switch plates, mirrors and toilet accessories mounted on surface. Submit drawings showing ceramic tile pattern elevations and floor plans. Submit manufacturer's preprinted installation instructions.

3.3 INSTALLATION OF WALL TILE

Install wall tile in accordance with the TCNA Hdbk, method W244C-15 and with grout joints as recommended by the manufacturer for the type of tile.

Install wall tile in showers in accordance with TCNA Hdbk, Method B415-15.

3.3.1 Latex-Portland Cement Mortar

Use Latex-Portland Cement to install tile in accordance with TCNA Hdbk.

Use Latex Portland Cement when installing porcelain ceramic tile.

SECTION 09 30 13 Page 7

3.3.2 Ceramic Tile Grout

Prepare and install ceramic tile grout in accordance with TCNA Hdbk.

Provide and apply manufacturer's standard product for sealing grout joints in accordance with manufacturer's recommendations.

3.4 INSTALLATION OF FLOOR TILE

Install floor tile in accordance with TCNA Hdbk method F113A-15 and with grout joints as recommended by the manufacturer for the type of tile.

Install shower receptors in accordance with TCNA Hdbk method B415.

3.4.1 Latex-Portland Cement

Use Latex-Portland cement mortar to install tile directly over properly cured, plane, clean concrete slabs in accordance with TCNA Hdbk. Use Latex Portland cement when installing porcelain ceramic tile.

3.4.2 Ceramic Tile Grout

Prepare and install ceramic tile grout in accordance with TCNA Hdbk.

Provide and apply manufacturer's standard product for sealing grout joints in accordance with manufacturer's recommendations.

3.4.3 Waterproofing

Install waterproofing membrane per manufacturer's requirements. Ensure full coverage.

3.4.4 Concrete Fill

Provide a 3500 psi concrete fill mix to dry as consistency as practicable. Spread, tamp, and screed concrete fill to a true plane, and pitch to drains or levels as shown. Thoroughly damp concrete fill before applying setting-bed material. Reinforce concrete fill with one layer of reinforcement, with the uncut edges lapped the width of one mesh and the cut ends and edges lapped a minimum 2 inch. Tie laps together with 18 gauge wire every 10 inch along the finished edges and every 6 inch along the cut ends and edges. Provide reinforcement with support and secure in the centers of concrete fills. Provide a continuous mesh; except where expansion joints occur, cut mesh and discontinue across such joints.

Provide reinforced concrete fill under the setting-bed where the distance between the under-floor surface and the finished tiles floor surface is a minimum of 2 inches, and of the same thickness that the mortar setting-bed over the concrete fill with the thickness required in the specified TCNA Hdbk method.

3.5 INSTALLATION OF TRANSITION STRIPS

Install transition strips where indicated, in a manner similar to that of the ceramic tile floor and as recommended by the manufacturer. Provide thresholds full width of the opening. Install head joints at ends not exceeding 1/4 inch in width and grouted full.

3.6 EXPANSION JOINTS

Provide movement joints per TCNA Hdbk, EJ171 and ASTM C1193. Form and seal joints as specified in Section 07 92 00 JOINT SEALANTS.

SECTION 09 30 13 Page 8

3.6.1 Walls

Provide expansion joints at control joints in backing material. Wherever backing material changes, install an expansion joint to separate the different materials.

3.6.2 Floors

Provide expansion joints over construction joints, control joints, and expansion joints in concrete slabs. Provide expansion joints where tile abuts restraining surfaces such as perimeter walls, curbs and columns and at intervals of 24 to 36 feet each way in large interior floor areas and 12 to 16 feet each way in large exterior areas or areas exposed to direct sunlight or moisture. Extend expansion joints through setting-beds and fill.

3.7 CLEANING AND PROTECTING

Upon completion, thoroughly clean tile surfaces in accordance with manufacturer's approved cleaning instructions. Do not use acid for cleaning glazed tile. Clean floor tile with resinous grout or with factory mixed grout in accordance with printed instructions of the grout manufacturer. After the grout has set, provide a protective coat of a noncorrosive soap or other approved method of protection for tile wall surfaces. Cover tiled floor areas with building paper before foot traffic is permitted over the finished tile floors. Provide board walkways on tiled floors that are to be continuously used as passageways by workmen.

Replace damaged or defective tiles. Submit copy of manufacturer's printed maintenance instructions.

SECTION 09 30 13 Page 9

SECTION 09 51 00

ACOUSTICAL CEILINGS

08/10

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A641/A641M (2009a; R 2014) Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire

ASTM C423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method

ASTM C635/C635M (2013a) Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings

ASTM C636/C636M (2013) Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels

ASTM C834 (2014) Latex Sealants

ASTM E1477 (1998a; R 2013) Luminous Reflectance Factor of Acoustical Materials by Use of Integrating-Sphere Reflectometers

ASTM E580/E580M (2014) Application of Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels in Areas Requiring Moderate Seismic Restraint

ASTM E795 (2005; R 2012) Mounting Test Specimens During Sound Absorption Tests

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED (2009) LEED NC Reference Guide for Green Building Design and Construction

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS Scientific Certification Systems (SCS)Indoor Advantage

U.S. DEPARTMENT OF DEFENSE (DOD)

UFC 3-310-04 (2013) Seismic Design for Buildings

SECTION 09 51 00 Page 1

UL ENVIRONMENT (ULE)

ULE Greenguard UL Greenguard Certification Program

UNDERWRITERS LABORATORIES (UL)

UL Fire Resistance (2014) Fire Resistance Directory

1.2 SYSTEM DESCRIPTION

Provide acoustical units mechanically mounted on a ceiling suspension system for acoustical treatment. The unit size, texture, finish, and color must be as specified. The location and extent of acoustical treatment shall be as shown on the approved detail drawings. Submit drawings showing suspension system, method of anchoring and fastening, details, and reflected ceiling plan. Coordinate with paragraph RECLAMATION PROCEDURES for reclamation of mineral fiber acoustical ceiling panels to be removed from the job site.

1.2.1 Ceiling Sound Absorption

Determine the Noise Reduction Coefficient (NRC) in accordance with ASTM C423 Test Method. Provide a ceiling system with noise reduction class (NRC) of 0.95.

1.2.2 Light Reflectance

Determine light reflectance factor in accordance with ASTM E1477 Test Method.

1.2.3 Other Submittals Requirements

The following shall be submitted:

a. Manufacturer's data indicating percentage of recycle material in acoustic ceiling tiles to verify affirmative procurement compliance.

b. Total weight and volume quantities of acoustic ceiling tiles with recycle material.

c. Manufacturer's catalog showing UL classification of fire-rated ceilings giving materials, construction details, types of floor and roof constructions to be protected, and UL design number and fire protection time rating for each required floor or roof construction and acoustic ceiling assembly.

d. Reports by an independent testing laboratory attesting that acoustical ceiling systems meet specified requirements. Data attesting to conformance of the proposed system to Underwriters Laboratories requirements for the fire endurance rating listed in UL Fire Resistance may be submitted in lieu of test reports.

e. Certificate attesting that the mineral based acoustical units furnished for the project contain recycled material and showing an estimated percent of such material.

SECTION 09 51 00 Page 2

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.