VOLUME_1-_2_of_3.pdf

PDF 32 MB Posted

Attached to
MISSION TRAINING CENTER (MTC) SIMULATION CENTER AT FORT HOOD, TEXAS
Solicitation number
W9126G-17-R-0008
Issued by

About this file

RFP Drawing VOL 1 (2 of 3)

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

VEST.

TR

VEST.

SECURE

ROOM

CORRIDOR

13 14 15 16 17 18

V

W

X

Y

Z

BB

CC

DD

MATCHLINE

M A

T C

H

LI

N E

AA

EE

1' - 4"

1' - 0" 6' - 6" 1' - 0"

1' - 4"

85' - 3"

1' - 4"

7' - 2"

1' - 4"

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

MATCHLINE

M A

T C

H

LI

N E

CORRIDOR

1'

1'

4'

1'

5"

6'

1'

6'

1'

8'

9'

0"

2'

1"

5'

8'

1"

0"

0"

9'

1/

8"

/8

/4

/4

8'

/4

7 5/8"

2' - 4 1/4"

TSVA

065A

060A

070A

077A

STORAGE

OFFICE

TR ROOM

3' - 11"

10 3/4"

8' - 6"

10 3/4"

3' - 11" 35' - 9 3/4" 2' - 8" 2' - 8" 35' - 9 3/4" 3' - 11"

10 3/4"

8' - 6"

/4 "8'

" 10

/4

/4

5'

0"

2'

2'

5'

0"

2'

2'

3/ 4"

5'

/8

9'

/8

9'

/2

/2

10 3/4" 13' - 0" 12' - 2" 2' - 11 1/4" 15' - 4 3/4" 31' - 3 1/2" 10' - 0"

10 3/4"

2' - 4" 7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8"

7 5/8"

8"

EQ

8" 7 5/8"

9' - 3 1/2"

ELEC

A

A

A

A

MM

B

B

B

B B

B B

B

M

M

A

A

A

A

A A

B B

AE513

C3

AE513

B3

AE513

B4

AE513

A4 AE511

A1

AE511

D1

L

L

B

M

L

L

L L

L

L L

M

M

3' - 8 1/2"

1'

/4

A4

AE316

4 4

XX XX XX XX XX XXXX XX XX

XX XXX XX XXXX XX XX

X X

X X

X X

X X

X

X

X

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:2

P M

P N

F

Y

/2

/2

AE108

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'G

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'G'

KEYED NOTES

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS ONLY TO

THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. REFER TO ENLARGED PLANS WHERE THEY OCCUR FOR PARTITION TYPES.

D. PROVIDE PARTITION TYPE "B" ABOVE DOORS/ PAIRS OF DOORS/ SIDELIGHTS

CROSSING CORRIDORS, UNLESS NOTED OTHERWISE.

1 10'-0" H OPERABLE PARTITION W/ PASS DOOR AND TRACK

2 NOT USED

3 SOFFIT ABOVE, TYP.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 7'-10" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND FRAMES.

8 PROVIDE FULL-LENGTH BY FULL HEIGHT MARKER BOARD PAINT

9 PROVIDE FULL LENGTH BY 11'-0" HIGH MARKER BOARD PAINT

10 LINE OF RFI FOIL TAPE AT FLOOR AND STRUCTURAL STEEL DECK

ABOVE. PROVIDE 12" LAP ONTO FLOOR AND STEEL DECK ABOVE.

PROVIDE 16 GAUGE STUDS, MINIMUM, FOR PARTITIONS CONSTRUCTED

UTILIZING FOIL-BACKED GYPSUM BOARD AND RFI FOIL TAPE

11 24" X 24" WEATHERTIGHT ACCESS PANEL: BOTTOM AT +6'-0" A.F.F.

12 CHAIN LINK FENCE, REFER TO CIVIL DRAWINGS

13 CHAIN LINK FENCE GATE, REFER TO CIVIL DRAWINGS

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

T E

COMPUTER

REPAIR

ROOM

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

13 14 15 16 17 18

L

M

N

R

Q

S

U

V

W

MATCHLINE

T

CORRIDOR

P

Q.1

U.1

CORRIDOR

JANITOR

8' - 6" 29' - 0" 14' - 3 1/2" 14' - 3 1/2" 29' - 0" 8' - 6" 1' - 4"

MATCHLINE

M A

T C

H

LI

N E

MATCHLINE

MATCHLINE

CORRIDOR

8'

2'

1'

8'

4'

0"

1'

8'

CORRIDOR

/4

8'

/4

/4

/4

9 9

4 21

Q.7

092089087

077A

079 078

080 081

082 083

10 3/4"

8' - 6"

10 3/4"

2' - 8" 2' - 8"

10 3/4"

8' - 6"

3' - 11"

10 3/4"

8' - 6"

10 3/4"

3' - 11" 24' - 2 1/4" 11' - 7 1/2"

2' - 8" 2' - 8"

11' - 7 1/2" 24' - 2 1/4" 3' - 11"

10 3/4"

8' - 6"

/8 "8'

/4

/4

5'

0"

2'

2'

5'

0"

2'

2'

5'

0"

2'

2'

/4

5'

0"

/4 "8'

" 10

/4

10 3/4" 8' - 6" 10 3/4" 22' - 10" 20' - 0" 13' - 10 1/4" 13' - 3 3/4" 14' - 10 1/8"

10 1/8"

8' - 6" 10 3/4"

A

A

A

B

A A

A

A

A A

A

A

A A

A A

B

B

BB

B

B

FD

AE513

B2

/4

8'

/8

I

10 10

AE507

A3

AE507

A2

D

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:2

P M

P N

F

Y

/2

/2

AE109

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'H

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'H'

KEYED NOTES

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS ONLY

TO THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. PROVIDE PARTITION TYPE "B" ABOVE DOORS/ PAIRS OF DOORS/ SIDELIGHTS

CROSSING CORRIDORS, UNLESS NOTED OTHERWISE.

1 10'-0" H OPERABLE PARTITION W/ PASS DOOR AND TRACK

2 OPERABLE PARTITION DOOR.

3 SOFFIT ABOVE, TYP.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 7'-10" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND FRAMES.

8 PROVIDE FULL-LENGTH BY FULL HEIGHT MARKER BOARD PAINT

9 PROVIDE FULL LENGTH BY 11'-0" HIGH MARKER BOARD PAINT

10 ALIGN SURFACES

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

MCER

SIPR TR

NIPR TR

COMPUTER

REPAIR

ROOM

ESS

STORAGE

SECURITY

STORAGE

TR ROOM

ELEC.

ROOM

13 14 15 16 17 18

F

G

J

K

L

M

H

CORRIDOR

JANITOR

OFFICE

AV

CORRIDOR

144 MATCHLINE

MATCHLINE

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

CORRIDOR

AAR

8'

8'

5'

8'

7"

4' - 7"

H.2

A3

AE313

145 143

092089

035B

124A

124123

123A

10 3/4" 8' - 6" 10 3/4" 56' - 8 1/4" 8' - 0" 20' - 1 7/8" 10 1/8" 8' - 6"

8'

/4

/8

/8

/4

8'

/4

10 3/4" 8' - 6" 10 3/4" 22' - 10" 20' - 0" 13' - 10 1/4" 13' - 3 3/4" 14' - 10 1/8"

10 1/8"

8' - 6" 10 3/4"

/8

8'

/8

5/ 8"

1'

/4

/8

/8 "8'

/4

B

B

A A

B

B

B

B

B

F

F

F

F

B

B

B

B

B

B B

B

B

B B

B

B

5.

125.00°

2'

/2

9'

2'

/2

D

D

B

10 10

D

D

D

D

D

D

D

DD

D

D

D

CORRIDOR

/4

3'

/4

5' - 6" 3' - 4 1/2"

AE801

A4

A7

EL + 0'-0"

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:3

P M

P N

F

Y

/2

/2

AE110

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'J

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'J'

KEYED NOTES

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS

ONLY TO THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. PROVIDE PARTITION TYPE "B" ABOVE DOORS/ PAIRS OF DOORS/ SIDELIGHTS

CROSSING CORRIDORS, UNLESS NOTED OTHERWISE.

1 10'-0" H OPERABLE PARTITION W/ PASS DOOR AND TRACK

2 BUILT IN MILLWORK

3 SOFFIT ABOVE, TYP.

4 PARTITION TYPE "D" SHOWN THIS SPACE FOR CLARITY

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 NOT USED

8 PROVIDE FULL LENGTH BY FULL HEIGHT MARKER BOARD PAINT

9 PROVIDE FULL LENGTH BY 11'-0" HIGH MARKER BOARD PAINT

10 ALIGN SURFACES

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

12 13 14 15 16 17 18

A

C

D

E

F

G

A.4

A.8

OFFICE

OFFICE

OFFICE

CONTRACT

OFFICES

TR ROOM

TOILET

NIPR CAFE

CORRIDOR

MAIN

CONFERENCE

CONFERENCE

CONFERENCE

29' - 0" 8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

MATCHLINE

M A

T C

H

LI

N E

M A

T C

H

LI

N E

8" 7 5/8"

8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8" 8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8" 8"

EQ

8" 7 5/8" 8"

EQ

8" 7 5/8" 8"

EQ

8" 7 5/8" 8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8"

8"

EQ

8" 7 5/8"

7' - 11 1/4" 8' - 6"

2'

" 1'

8'

0"

8'

8'

9'

0"

8'

AAR

1' - 4"

8' - 2" 9' - 11" 7' - 8 1/2"

3' - 11" 10 3/4"

7"

4' - 7"

B

149 145

140A

124A 123A

145A

BREAK

ROOM

143A

10 3/4" 8' - 6" 10 3/4" 56' - 8 1/4" 8' - 0" 20' - 1 7/8" 10 1/8" 8' - 6"

/8 "8'

/4

/8

8'

/8

6' - 3 1/2" 8' - 3 1/2" 6' - 4" 5' - 6" 15' - 11 1/2" 15' - 3" 5' - 6"

3' - 4 1/2"

1' - 4" 24' - 4" 2' - 11" 13' - 4 5/8"

4' - 0"

4 5/8" 10' - 4 5/8"

10 1/8"

8' - 6" 10 3/4"

/4

4'

/4

3'

1"

8'

/4

2' - 9 1/8" 2' - 9 1/8"

/4

1"

5'

7'

/2

/8

/8 "8'

" 10

/8

10 3/4" 9' - 6"

B

B

B

B

H

J.1

J.1

J.1

J.1

F

J.1

J.1

J.1

J.1

J.1

J.1

J.1

J.1

AE402

B4

H

B

B

B

B

H

H

B

H

H

B

B

B

B

B

B

B

B B

N

B

B

H

5.

B

B

9'

2'

/2

AE802D1 AE802

D3

AE802C2

W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4 W4

AE511

B2

D2

WORK

ROOM

A

D B

1'

H

H

3' - 1"

AE506

C1

AE507

A1

REF

(NIC)

/8

4" 7'

/4

3'

/4

5' - 6" 3' - 4 1/2"

ABOVE +24'-10"

A.F.F.

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:3

P M

P N

F

Y

/2

/2

AE111

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'K

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'K'

KEYED NOTES

1 10'-0" H OPERABLE PARTITION AND TRACK

2 BUILT IN MILLWORK

3 SOFFIT ABOVE, TYP.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 7'-0" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND FRAMES.

8 PRINTER (GFGI)

9 PROVIDE FULL LENGTH BY FULL HEIGHT MARKER BOARD PAINT

10 RECYCLING CENTER CONTAINERS (GFGI)

11 24" X 24" ACCESS PANEL: BOTTOM AT +6'-0" A.F.F.

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS ONLY

TO THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. REFER TO ENLARGED PLANS WHERE THEY OCCUR FOR PARTITION TYPES.

D. PROVIDE PARTITION TYPE "B" ABOVE DOORS/ PAIRS OF DOORS/ SIDELIGHTS

CROSSING CORRIDORS, UNLESS NOTED OTHERWISE.

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

17 18 19 20 21 22

J

K

L

M

N

R

Q

P

Q.1

JANITOR

MALE

LATRINE

WATER

HEATER

MUD ROOM

FEMALE

LATRINE

CORRIDOR

RTOC

RTOC

RTOC

OFFICE

OFFICE

STORAGE

ELEC

SAT ESS

OFFICE

TR ROOM

STORAGE

MATCHLINE

MATCHLINE

M A

T C

H

LI

N E

8' - 6" 40' - 0" 36' - 0" 32' - 0" 32' - 0"

EL -3'-4"

AE402

B1

1'

/4

/4

8'

" 10

/4

3'

1"

/4

4'

3/

6"

8'

4'

/8

/8 "8'

/4

/4

2'

" 1'

8 8

3 3

80.00°EL -1'-8"

DNDN

Q.7

A3

AE313

A4

AE313

112 113 114 115 116 119 120

103A 104A

101099

097 100

099B

118A

103102

102A

099A

CORRIDOR

5'

4'

3' - 11"

10 3/4"

8' - 6"

8' - 10 5/8" 23' - 4 3/16" 5' - 10"

2' - 8" 2' - 8"

5' - 10" 20' - 10"

2' - 8" 2' - 8"

10 1/8"

8' - 6" 10 3/4" 16' - 6" 16' - 6" 39' - 2" 16' - 2" 8' - 7 1/4" 4' - 2 3/4" 5' - 7" 4' - 4 1/2"

4' - 0 1/4"

4' - 7 1/2" 7' - 11" 11' - 5" 10 3/4"

AE112

B2

A3

AE112

7'

3"

10 3/4"

A

A

B

B

B

F

F 4

A

E

CORRIDOR

H H

A A

B

B

B

B

B

B

B

B

B

F C

B C

C

BC

B

B

B

F

125.00°

F9'

FD

FD

FD

FD

FD FD

FDFD

C1

AE411

A1

AE316

1'

AE513

B2

AE511

B1

AE511

A3

A4

AE311

I

C

11 11

AE507

A3

AE507

A2

4 4

4' - 0" 8' - 2" 3' - 4" 4' - 6" 9' - 2" 3' - 10"

3' - 0"

16' - 0" 10' - 8" 3' - 4"

2' - 0"

16' - 0" 10' - 8" 3' - 4"

2' - 0"

FD

FD

B.1

B.1

TYP.

EL + 0'-0"

STEEL MESH IN

STEEL CHANNEL

FRAME

CONT. JAMB

1" X 1" X 1/8" STOP

7'

STEEL

STRUCTURAL TUBE

3" X 2" X 1/4"

STEEL MESH IN

STEEL CHANNEL

FRAME W/ 1/8" STEEL

COVER PLATE, CONT.

1/16" STEEL WIRE

WOVEN INTO 2"

DIAMOND MESH

STEEL MESH IN

STEEL CHANNEL

FRAME

1/16" STEEL WIRE

WOVEN INTO 2"

DIAMOND MESH

STEEL STRUCTURAL

TUBE 3" X 2" X 1/4"

FACE OF WALL

2"

1/8" THICK X 2 1/2" X

3/4" WIDE LOCKING

PADLOCK TAB

DOOR SWING

SHOWN DASHED

FOR CLARITY

STEEL MESH IN STEEL

CHANNEL FRAME W/

1/8" STEEL COVER

PLATE, CONT.

MIN. 2 HINGES PER

DOOR

FRAME CHANNEL

CENTER REINF.

CHANNEL

CORNER POST

BEYOND

FRAME CHANNEL

4"

4"

CAST IRON SHOE

ANCHORED TO CONC.

FLOOR W/ 1/4" - 3/4"

EPOXY ANCHORS

1/16" STEEL WIRE

WOVEN INTO 2"

DIAMOND MESH

FACE OF

STRINGER

3 x 3 x 1/4

STEEL ANGLE

1/16" STEEL WIRE

WOVEN INTO 2"

DIAMOND MESH

STEEL

STRUCTURAL TUBE

3" X 2" X 1/4"

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:4

P M

P N

F

Y

/2

/2

AE112

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'L

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'L'

KEYED NOTES

1 12'-0" H OPERABLE PARTITION W/ PASS DOOR AND TRACK

2 OPERABLE PARTITION DOOR.

3 SOFFIT ABOVE, TYP.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 7'-0" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND FRAMES.

8 PROVIDE FULL-LENGTH BY FULL HEIGHT MARKER BOARD PAINT

9 PROVIDE FULL LENGTH BY 13'-0" HIGH MARKER BOARD PAINT

10 STEEL GRATING

11 STEEL SHELVING UNITS - TYPE 1

1 1/2" = 1'-0" B1

WIRE MESH DOOR HEAD

1 1/2" = 1'-0" A1

TYPICAL DETAIL @

INTERMEDIATE BRACE

1 1/2" = 1'-0" B2

TYPICAL DETAIL @

WALL INTERFACE

1 1/2" = 1'-0" A2

WIRE MESH DOOR JAMB

1 1/2" = 1'-0"

A3

TYPICAL DETAIL THRU

WIRE MESH PARTITION

1 1/2" = 1' - 0" 0 6" 1' 2'3" 9"

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS ONLY TO

THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. REFER TO ENLARGED PLANS WHERE THEY OCCUR FOR PARTITION TYPES.

D. PROVIDE PARTITION TYPE "B" ABOVE DOORS/ PAIRS OF DOORS/ SIDELIGHTS

CROSSING CORRIDORS, UNLESS NOTED OTHERWISE.

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

1 1/2" = 1'-0"

A4

TYPICAL DETAIL @

WALL INTERFACE

@ STAIR

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

SIPR TR

NIPR TR

A3

AE311

17 18 19 20 21 22

C

D

E

F

G

J

H

A.8

CAGED

STORAGE

CAGED

STORAGE

STORAGE

AAR

AV

STORAGE

RECYCLED

STORAGE

CORRIDOR

STORAGE

MECHANICAL

FIRE PUMP

OFFICE

NIPR CAFE

M A

T C

H

LI

N E

MATCHLINE

1' - 4" 3" 6' - 6" 12' - 5" 16' - 0"

1' - 1"

6' - 4" 4' - 7" 4' - 0" 2' - 4"

3' - 4"

10' - 4" 3' - 10" 6' - 4" 5' - 10" 16' - 0" 16' - 0" 16' - 0" 16' - 0"

8' - 6" 40' - 0" 36' - 0" 32' - 0" 32' - 0"

8'

8'

9'

0"

8'

7'

EL -3'-4"

OFFICE

EL -3'-4"

AAR

MAIN ELEC

3' - 11" 10 3/4"

7"

4' - 7" 8' - 3" 8' - 10" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 13' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 22' - 3"

80.00°

80.00°

EL -1'-8"

EL -1'-8"

/4

6'

/8

DN

DN

DN

DN

H.2

A4

AE313

B

140A

134A

134 130

124A

124123

123A

095 136 131

118C

136A

118B

AAR

AE403

A1

AS IS +15'-0"

A.F.F.

+27'-0" A.F.F.

/4

3/ 8"

/8

8'

/4

4'

5'

/2

5'

4'

10 1/8" 8' - 6"

10 1/8"

8' - 6" 10 3/4"

1"

5'

7'

/2

/8

/8 "8'

" 10

/8

10 1/8"

8' - 6" 10 3/4" 16' - 6" 16' - 6" 39' - 2" 16' - 2" 8' - 7 1/4" 4' - 2 3/4" 5' - 7" 4' - 4 1/2"

4' - 0 1/4"

4' - 7 1/2" 7' - 11" 11' - 5" 10 3/4"

A3

AE112

/4

/4

8'

/4

/4

3'

4'

3'

2'

7'

3"

/4

3"

/4

6'

10 3/4" 9' - 6" 5' - 4" 24' - 3 1/4" 2' - 8" 16' - 8" 16' - 8" 6' - 3"

B

F

F

F

F

B

B

H

H

B

B

B

B

B

B

AE112

B2

AE112

A1

AE112

A2

B1

AE112

N N

N

N

N

N C

C

C

C C

C

C

B

B

B

A

A

A

A

E

E

E

E

H

F C

C

F

5.

125.00°

F

F

F

4' - 0" 7' - 6" 6' - 6" 5' - 8 3/4" 6' - 6" 7' - 6" 4' - 4"

B

B

2'

/2

9'

9'

2'

/2

/2

/2

C

B

C

W3

C1

AE411

A2

AE316

A1

AE316

A3

AE316

1'

FD

FD

FDFD

FD

N

AE511

B2

C

C

B

11 11

AE801 C3

AE506

C1

AE507

A1

AE411A1

AE410

C1

A1

C4

AE106

D

CORRIDOR

AE511

B1 TYP.

1/ 4"

4'

1/ 4"

5' - 0" 20' - 0" 8' - 0" 5' - 0" 20' - 0"

+24'-10" A.F.F.

ABOVE

FD

AE505

A3

1' - 3 7/8" TYP.

B.1

B.1

CORRIDOR

D1

AE412

EL + 0'-0"

EL + 0'-0"

AE403

B1

AE403

C1

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:5

P M

P N

F

Y

/2

/2

AE113

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'M

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'M'

KEYED NOTES

1 OVERHEAD COILING DOOR

2 ROOF ACCESS STAIR

3 SOFFIT ABOVE, TYP.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 7'-0" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND

FRAMES.

8 PROVIDE FULL-LENGTH BY FULL HEIGHT MARKER BOARD PAINT

9 PROJECTION SCREEN VIEWING AREA SHOWN DASHED

10 OBSERVATION WINDOW AND COUNTER WITH HM FRAME AND

GLAZING

11 STEEL SHELVING UNITS - TYPE 1

12 STEEL SHELVING UNITS - TYPE 2

13 NOT USED

14 3' - 0" x 4'-0" HC SEATING AREA

15 SECURITY WIRE MESH FENCE

16 ALIGN SURFACES

17 4" RISER

18 FIRE EXTINGUISHER WITH WALL BRACKET

19 BUILT-IN FIXED TABLES AT THESE TIERS. DASHED TABLES AND ALL

CHAIRS OTHERWISE ARE LOOSE FURNITURE (NIC). REFER TO

INTERIOR PACKAGE

20 MOTORIZED PROJECTOR LIFT ABOVE (CFCI).

21 ACOUSTICAL WOOD PANELS ON GYPSUM BOARD PARTITION.

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS ONLY

TO THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. REFER TO ENLARGED PLANS WHERE THEY OCCUR FOR PARTITION TYPES.

D. PROVIDE PARTITION TYPE "B" ABOVE DOORS/ PAIRS OF DOORS/ SIDELIGHTS

CROSSING CORRIDORS, UNLESS NOTED OTHERWISE.

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

22 23 25 27 28 29 31

J

K

L

M

N

R

Q

P

26 30

Q.1

RTOC

RTOC

RTOC

RTOC

RTOC

CORRIDOR

ELEC.ROOM

MATCHLINE

M A

T C

H

LI

N E

2' - 0" 3' - 4" 10' - 8" 16' - 0" 16' - 0" 10' - 8" 3' - 4"

2' - 0"

16' - 0" 10' - 8" 3' - 4"

2' - 0"

16' - 0" 10' - 8" 3' - 4" 28' - 8" 3' - 4" 4' - 0" 3' - 4" 26' - 8"

1' - 8"

32' - 0" 22' - 0" 10' - 0" 11' - 0" 21' - 0" 32' - 0" 32' - 0" 12' - 7" 19' - 5"

RTOC

TR ROOM

1'

0"

1'

5" 6'

1'

8'

5'

8'

2'

" 1'

1' - 4" 52' - 8" 1' - 4" 117' - 3" 1' - 4 5/8" 18' - 0 3/8" 1' - 8"

5 76

Q.7

1'

A4

AE313

109A108A107A106A105A104A

110A

105104 107106 108 109

EL+ 0'-0" DN

1'

1'

/4 " 10

/4

8'

/4

/4

2' - 8" 2' - 8" 20' - 10" 5' - 10"

2' - 8" 2' - 8" 5' - 10" 20' - 10"

2' - 8" 2' - 8" 20' - 10" 5' - 10"

2' - 8" 2' - 8" 5' - 10" 20' - 10"

2' - 8" 2' - 8" 20' - 10" 5' - 10"

2' - 8" 2' - 8"

5' - 10" 22' - 8" 10"

10 3/4"

10 3/4" 31' - 1 1/4" 10' - 6" 11' - 6"

A A

H

H

HA

A A

A

B

B

B BB

9 9 9 99

1'

5'

A5

AE316

4 4

4 4

2' - 0"

AE511

B1

B.1

B.1

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :0

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:0

P M

P N

F

Y

/2

/2

AE114

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'N

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'N'

GENERAL NOTES KEYED NOTES

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS

ONLY TO THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. REFER TO ENLARGED PLANS WHERE THEY OCCUR FOR PARTITION TYPES.

1 12'-0" H OPERABLE PARTITION W/ PASS DOOR AND TRACK

2 OPERABLE PARTITION DOOR.

3 SOFFIT ABOVE, TYP.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

5 FIRE EXTINGUISHER CABINET (CFCI).

6 ELECTRIC WATER COOLER.

7 7'-0" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND FRAMES.

8 PROVIDE FULL-LENGTH BY FULL HEIGHT MARKER BOARD PAINT

9 PROVIDE FULL LENGTH BY 13'-0" HIGH MARKER BOARD PAINT

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEY PLAN

TYP.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

22 23 25

C

D

E

F

G

J

H

ELEC.ROOM

RECYCLED

STORAGE

DISINTEGRATOR

TRAINING

SUPPLY

STORAGE

MATCHLINE

M A

T C

H

LI

N E

TR ROOM

16' - 0" 3' - 9" 12' - 3" 22' - 0" 4' - 1 1/2" 16' - 10 1/2" 1' - 8" 16' - 6" 1' - 4"

32' - 0" 22' - 0" 10' - 0" 11' - 0" 19' - 6"

6'

1'

7'

1'

1'

0"

8'

8'

9'

0"

8'

7'

CORRIDOR

1' - 4"

52' - 8"

1' - 4"

39' - 2"

2'

/8

/8

8'

/4

/8

1'

/8

5'

1'

1' - 4" 6' - 4" 2' - 8" 9' - 10 1/2" 10' - 5 1/2"

2' - 0 1/2"

8' - 4" 32' - 7 1/2" 8' - 0"

DN

H.2

A4

AE313

B

130A

118C

118B

EL+ 0'-0"

EL -4'-0"

EL+ 0'-0" EL -4.65'DN

EL - 4'-9"

DN

A4

AE315

/8

/4

8'

/8

1'

/8

6'

1'

2'

1'

/4

/4

8'

/4

3'

4'

3'

2'

7'

C

B

C

C

C

C

C

C

B

C

H

A3

AE315

1'

1'

1'

AE407

A1

AE511

A2

AE511

D3

4' - 0"

5'

7R

.8

6"

'-0

6T

2"

'-0

EL+ 0'-0"

EL -4'-0"

D4

AE115

DN

DN

1' - 0" 8R @ 6.975" = 4.65' 7T @ 12" = 7' - 0"

30' - 0" 5' - 0" 24' - 6"

1'

1'

4'

0"

4'

0"

EL+ 0'-0"

AE505

A3

B.1

B.1

EL- 4.65'

EL-2.5 EL-2.601

T.O. SLAB

0'-0"

8"4"6T @ 12" = 6' - 0"1' - 0"

EL.

-4.65'

R

.9

4.

2'

0" 4"

4"

1' - 0"

2'

0"

2'

0"

AE115

C4

2'

0"

2'

0"

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :0

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:0

P M

P N

F

Y

/2

/2

AE115

P A

R T

IA

L F

L O

O R

P L A

N

A R

E A

'P

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1'-0"

PARTIAL FLOOR PLAN - AREA 'P'

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

GENERAL NOTES

KEYED NOTES

1 OVERHEAD COILING DOOR

2 DOCK LEVELER. COORDINATE PIT SIZE WITH DOCK LEVELER

MANUFACTURER. SLOPE PIT 1/2" FROM BACK TO FRONT OR AS

REQUIRED BY THE DOCK LEVELER MANUFACTURER

3 DOCK BUMPERS

4 STEEL ANGLE FRAME EMBEDMENT ALL AROUND DOCK LEVELER PIT.

REFER TO STRUCTURAL DRAWINGS

5 FIRE EXTINGUISHER CABINET (CFCI).

6 FIRE EXTINGUISHER WITH WALL BRACKET

7 7'-0" W x 10'-0" L RECESSED ENTRANCE FLOOR GRATING AND

FRAMES.

8 42" HIGH CLEAR ANODIZED ALUMINUM GUARDRAIL

9 CAST-IN-PLACE CONCRETE STEPS, SLAB ON GRADE

10 CENTERLINE OF DOCK LEVELER ON CENTERLINE OF OVERHEAD

COILING DOOR

11 CLEAR ANODIZED ALUMINUM HANDRAIL SYSTEM

12 ABRASIVE STAIR NOSING. PROVIDE 6" BETWEEN EDGE OF CONCRETE

CONSTRUCTION AND END OF ABRASIVE NOSING.

13 RETURN RAIL TO FINISH FLOOR. PROVIDE INTERMEDIATE VERTICAL

POSTS AS DETERMINED BY SPECIFIED DESIGN CALCULATIONS, BUT

NOT MORE THAN 48" O.C., UNLESS APPROVED BY CONTRACTING

OFFICER

A. PARTITION TAGS AND INFORMATION CONTAINED ON THIS SHEET PERTAINS

ONLY TO THE AREA WITHIN MATCHLINES AS INDICATED BY THE KEY PLAN BELOW.

B. UNLESS INDICATED OTHERWISE, ALL INTERIOR PARTITIONS ON THIS SHEET ARE

PARTITION TYPE "D"

C. REFER TO ENLARGED PLANS WHERE THEY OCCUR FOR PARTITION TYPES.

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

1/2" = 1'-0" D4

STAIR SECTION

1/2" = 1' - 0" 0 1' 5'6" 2' 3' 4'

1 1/2" = 1'-0" C4

DETAIL

1" = 1'-0" A4

TYP. HANDRAIL DETAIL FOR STEPS

IN SLAB ON GRADE

1" = 1' - 0" 0 6" 1' 3'2'

1 1/2" = 1' - 0" 0 6" 1' 2'3" 9"

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

S5D S5D S5D S5DS5D S5D S5D S5D S5D S5DS5D S5D

S5D S5D S5D S5DS5D S5D S5D S5D S5D S5DS5D S5D

2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 27 28 29 31

A

C

D

E

F

G

J

K

L

M

N

R

Q

S

U

V

W

X

Y

Z

BB

CC

DD

H

T

AA

P

26 30

EE

U.1

A.4

A.8

022 023 024

019020021

015 016 017

012013014

089088 087086

039 084 085

082041

043 044

049 076

073052

057 059 058

025 026

098 099 100

101 102 103 104 105 106 107 108 109

112 113 114

115 116

125 126

128129130

141142

143144

148149

150 151152

153154

156 157

158 159

Q.7

H.2

B

143A

062061064 067

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

DL OS

4' - 0" 4' - 0" 4' - 0" 4' - 0"

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :1

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:1

P M

P N

F

Y

/2

/2

AE116

O V

E R

A L L C

E

IL

IN

G

P L A

N

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/32" = 1'-0"

OVERALL CEILING PLAN

1/32" = 1' - 0" 0 5' 10' 20' 120'40' 60'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS OS OS

OSOSOS

OS OS OS

OSOSOS

OS

OS

OS

OS OS

OS

OS

OS

D L

DL

O S

OS

OS

OS

D L

S

S

S S

S

OS

O S

O S

C

DL

2 3 4 5 6 7 9 10

J

K

L

M

N

R

Q

S

U

V

W

T

P

Q.1

U.1

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

TRAINING

LIBRARY

STORAGE

TR ROOM

STORAGE

ELEC.

ROOM

SR.

LEADER

CONF. RM

SR.

LEADER

CONF. RM

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

8'

5'

8'

2'

" 1'

8'

4'

0"

1'

8'

5' - 0" 13' - 8" 16' - 8" 24' - 0" 30' - 4" 8' - 6" 31' - 4" 8' - 6"

MATCHLINE

MATCHLINEMATCHLINE

CORRIDOR

Q.7

EL + 9'-0"

EL + 10'-0" TYP

EL + 11'-0" TYP

EL + 11'-0" TYP

EL + 10'-0" TYP

EL + 10'-0" TYP

EL + 9'-0"

4 44

4 4

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:2

P M

P N

F

Y

/2

/2

AE117

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'A

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'A'

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +12'-9" A.F.F.

3 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +14'-6 1/2" A.F.F.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

KEYED NOTES

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS OS

OS

OS OS

OS

OS

L

OS

OS

OS OS

OS

DL

OS

OS

OS

O S

D D

OS

OS

S

S S

O S

OS

C

C

2 3 4 5 6 7 9 10

A

C

D

E

F

G

J

H

A.4

A.8

CLASSROOM

CLASSROOM

CLASSROOM

FEMALE

LATRINE

CORRIDOR

CORRIDOR

CLASSROOM

CLASSROOM

CLASSROOM

STORAGE

MALE

LATRINE

JANITORS

WATER

HEATER

MENS

LOBBY

WOMENS

CORRIDOR

MATCHLINE

M A

T C

H

LI

N E

M A

T C

H

LI

N E

CORRIDOR

8'

8'

9'

0"

8'

5' - 0" 13' - 8" 16' - 8" 24' - 0" 30' - 4" 8' - 6" 31' - 4" 8' - 6"

OFFICE

H.2

EL + 11'-0" TYP

EL + 10'-0" TYP

EL + 9'-0"

EL + 8'-0"

EL + 10'-0" TYP

EL + 11'-0" TYP

EL + 10'-0" TYP

B

6' - 6" 18' - 4" 6' - 6"

EL + 9'-0"

MINI

LOCKERS

EL + 8'-2"

EL + 8'-2"

EL + 8'-2"

EL + 8'-2"

EL + 8'-2" EL + 8'-2"

EL + 9'-0"

EL + 9'-0"

2'

4'

1' - 4"

4' - 0" 2' - 4" 16' - 0" 2' - 4" 4' - 0"

1' - 4"

EL + 9'-4"

AE404

C2

VESTIBULE

001A

EL + 14'-7 1/4"

EL + 11'-7 1/4"

EL + 23'-6"

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :2

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:2

P M

P N

F

Y

/2

/2

AE118

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'B

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'B'

CEILING PLAN LEGEND

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +12'-0" A.F.F.

3 12" X 12" ACCESS PANEL

4 LINE OF LOBBY CURTAIN WALL ABOVE

5 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

6 4" EXPANSION JOINT. PROVIDE 4" BREAK IN GYPSUM BOARD SOFFIT.

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

B. ALL GYPSUM BOARD CEILINGS IN LATRINES, TOILET ROOMS, SHOWER AREAS, AND

MUD ROOMS SHALL BE CONSTRUCTED USING 5/8" TYPE "X" GLASS MAT GYPSUM

SHEATHING.

KEYED NOTES

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS OS OS OS

OS OS OS OS

OS OS OS OS

OS OSOS OS

OS

OS

OS

OS

OS

OSOS

O S

D L

D L

D L

DL

9 10 11 12 13 14

V

W

X

Y

Z

BB

CC

DD

AA

EE

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

CORRIDOR

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

CORRIDOR

8' - 6"

MATCHLINEMATCHLINE

M A

T C

H

LI

N E

8'

9'

0"

2'

1"

5'

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

MATCHLINE

EL + 11'-0" TYP

EL + 10'-0" TYP

EL + 10'-0" TYPEL + 11'-0" TYP

4 4

4 4

4 4

4 4

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:3

P M

P N

F

Y

/2

/2

AE119

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'C

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'C'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +12'-0" A.F.F.

3 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +11'-5" A.F.F.

4 PROJECTOR ABOVE (GFGI), (TYP.) ON PROJECTOR MOUNT (CFCI).

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OSOSOSOS

OS OS OS OS

OSOSOSOS

D Z1

OSOS

O S

OS

OS

OS

OS

OS

OS

D L

DL

DL

D Z2

O S

9 10 11 12 13 14

L

M

N

R

Q

S

U

V

W

T

P

Q.1

U.1

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

WORK

CELL

CORRIDOR

CORRIDOR

WORK

CELL

WORK

CELL

CORRIDOR

WORK

CELL

CORRIDOR

037MATCHLINE

M A

T C

H

LI

N E

M A

T C

H

LI

N E

8'

2'

" 1'

8'

4'

0"

1'

8'

" MATCHLINE

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

CORRIDOR

Q.7

EL + 11'-0" TYP

EL + 10'-0" TYP

EL + 11'-0" TYP

EL + 10'-0" TYP

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:3

P M

P N

F

Y

/2

/2

AE120

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'D

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'D'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +12'-2" A.F.F.

3 EXPANSION JOINT

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS OS

OS

OS

OS

OS

OS

O S

OS

DL

DL

OS

OS OS OS

OS

O S

P

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

9 10 11 12 13 14

F

G

J

K

L

M

H

WATER

HEATER

TECH

CONTROL

CORRIDOR

WORK

ROOM

CORRIDOR

CORRIDOR

MATCHLINE

M A

T C

H

LI

N E

MATCHLINE

CORRIDOR

8'

8'

5'

8'

" CORRIDOR

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

M A

T C

H

LI

N E

CORRIDOR

ELEC

H.2

EL + 12'-0" TYP

EL + 10'-0" TYP

EL + 9'-0"

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :3

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:3

P M

P N

F

Y

/2

/2

AE121

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'E

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'E'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

3 EXPANSION JOINT

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OS OS

L

OS

OS

OS

OS

O S

OS

OS

OS

OS

OS

OS

OS

OS

DL

DL DL

D D

OS

P

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

9 10 11 12 13

A

C

D

E

F

G

A.4

A.8

OPEN

OFFICE

EXECUTIVE

CONFERENCE

ROOM

WORK

ROOM

M A

T C

H

LI

N E

M A

T C

H

LI

N E

MATCHLINE

CONTRACT

OFFICES

CHECK IN

OFFICE

OFFICE

OFFICE

OFFICE

LOBBY

8' - 6" 29' - 0" 28' - 7" 29' - 0"

8'

8'

9'

0"

8'

WORK

ROOM

TOILET

STORAGE

ELEC

CORRIDOR

144EL + 10'-0" TYP

EL + 8'-0" TYP

EL + 10'-0"

B

EL + 8'-2"

1' - 4"

EL + 14'-7 1/4"

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:4

P M

P N

F

Y

/2

/2

AE122

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'F

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'F'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

B. ALL 2 X 2 CEILING TILES THIS SHEET AT +9'-0" A.F.F. UNLESS OTHERWISE NOTED

C. ALL GYPSUM BOARD CEILINGS IN LATRINES, TOILET ROOMS, SHOWER AREAS, AND

MUD ROOMS SHALL BE CONSTRUCTED USING 5/8" TYPE "X" GLASS MAT GYPSUM

SHEATHING.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

3 EXPANSION JOINT

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS OS

OS OS

OS

OSOSOS

OSOS

OSOS

OSOS

OSOS

OS

OS

OS

OS

OS OS

D L

DL

D L

D L

OS

OS

OS

C C

OS

13 14 15 16 17 18

V

W

X

Y

Z

BB

CC

DD

AA

EE

WORK

CELL

WORK

CELL

CORRIDOR

WORK

CELL

WORK

CELL

VEST.

TR

VEST.

SECURE

ROOM

CORRIDOR

WORK

CELL

WORK

CELL

MATCHLINE

M A

T C

H

LI

N E

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

CORRIDOR

8'

9'

0"

2'

1"

5'

EL + 11'-0" TYP

EL + 10'-0" TYP

EL + 9'-0"

EL + 9'-0"

TR ROOM

ELEC

STORAGE

OFFICE

EL + 11'-0"

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :4

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:4

P M

P N

F

Y

/2

/2

AE123

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'G

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'G'

A. HEAVY DASHED LINE INDICATES LINE OF RFI FOIL TAPE AT FLOOR AND

STRUCTURAL STEEL DECK ABOVE. PROVIDE 12" LAP ONTO FLOOR AND STEEL DECK

ABOVE. PROVIDE 16 GAUGE STUDS, MINIMUM, FOR PARTITIONS CONSTRUCTED

UTILIZING FOIL-BACKED GYPSUM BOARD AND RFI FOIL TAPE

B. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

C. ALL 2 X 2 CEILING TILES THIS SHEET AT +9'-0" A.F.F. UNLESS OTHERWISE NOTED

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL: BOTTOM AT +11'-10" A.F.F.

3 LINE OF RFI FOIL TAPE AT FLOOR AND STRUCTURAL STEEL DECK ABOVE.

PROVIDE 12" LAP ONTO FLOOR AND STEEL DECK ABOVE. PROVIDE 16

GAUGE STUDS, MINIMUM, FOR PARTITIONS CONSTRUCTED UTILIZING

FOIL-BACKED GYPSUM BOARD AND RFI FOIL TAPE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OSOS

OSOS

OSOS

OS OS

OS OS

OS OS

OS OS

OS OS

O S

OS

OS

OS

OS

OS

DL

D L

DL

S

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

13 14 15 16 17 18

L

M

N

R

Q

S

U

V

W

T

P

Q.1

U.1

WORK

CELL

WORK

CELL

CORRIDOR

WORK

CELL

WORK

CELL

WORK

CELL

JANITOR

OFFICE

WORK

CELL

WORK

CELL

WORK

CELL

CORRIDOR

MATCHLINE

M A

T C

H

LI

N E

MATCHLINE

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

CORRIDOR

8'

2'

" 1'

8'

4'

0"

1'

8'

CORRIDOR

CORRIDOR

Q.7

EL + 11'-0" TYP

EL + 11'-0" TYP

EL + 10'-0" TYP

EL + 9'-0"

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:5

P M

P N

F

Y

/2

/2

AE124

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'H

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'H'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL IN SOFFIT FASCIA: BOTTOM AT +12'-0" A.F.F.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OS

OS

OS

OS

OS

OS

OS OS

DL

DL

S

OS

OS

OS

OSOSOSOS OS OS OS

OS

OS

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

13 14 15 16 17 18

F

G

J

K

L

M

H

COMPUTER

REPAIR

ROOM

STORAGE

SECURITY

STORAGE

TR ROOM

ELEC.

ROOM

WORK

CELL

JANITOR

OFFICE

MCER

CORRIDOR

AV

MAIN

CONFERENCE

SIPR TR

NIPR TR

CORRIDOR

MATCHLINE

MATCHLINE

M A

T C

H

LI

N E

CORRIDOR

ESS

8'

8'

5'

8'

8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

H.2

EL + 11'-0" TYP

EL + 12'-0" TYP

EL + 12'-0" TYP

EL + 9'-0"

EL + 9'-0"

EL + 12'-0" TYP

EL + 12'-0" TYP

AAR

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:5

P M

P N

F

Y

/2

/2

AE125

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'J

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'J'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

B. ALL 2 X 2 CEILING TILES THIS SHEET AT +9'-0" A.F.F. UNLESS OTHERWISE NOTED

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OSOS

OS

OS

OS

OS

OS

OS OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

DL

OS

C

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

12 13 14 15 16 17 18

A

C

D

E

F

G

A.4

A.8

OFFICE

OFFICE

CONTRACT

OFFICES

TOILET

MAIN

CONFERENCE

CONFERENCE

CONFERENCE

WORK

ROOM

CONTRACT

OFFICES

TR ROOM

CORRIDOR

MATCHLINE

M A

T C

H

LI

N E

M A

T C

H

LI

N E

29' - 0" 8' - 6" 29' - 0" 28' - 7" 29' - 0" 8' - 6"

OFFICE

8'

8'

9'

0"

8'

MAIN ELEC

STORAGE

ELEC

EL + 8'-0"

EL + 10'-0" EL + 10'-0"

EL + 10'-0" TYP

B

EL + 9'-0"

BREAK

ROOM

143A

EL + 12'-0" TYP

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :5

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:5

P M

P N

F

Y

/2

/2

AE126

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'K

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'K'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

B. ALL 2 X 2 CEILING TILES THIS SHEET AT +9'-0" A.F.F. UNLESS OTHERWISE

NOTED

C. ALL GYPSUM BOARD CEILINGS IN LATRINES, TOILET ROOMS, SHOWER

AREAS, AND MUD ROOMS SHALL BE CONSTRUCTED USING 5/8" TYPE "X" GLASS

MAT GYPSUM SHEATHING.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OS

OS OS

OS

OS OS

OSOS

OS

OS

OS

OS

OS

OS OS OS

OS

OS

OS

DL

OS

S

S

S

OS

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

17 18 19 20 21 22

J

K

L

M

N

R

Q

P

Q.1

JANITOR

MALE

LATRINE

OFFICE

WATER

HEATER

MUD ROOM

FEMALE

LATRINE

CORRIDOR

RTOC

CAGED

STORAGE

STORAGE

OFFICE

STORAGE

114 ELEC

SAT ESS

RTOC

MATCHLINE

MATCHLINE

M A

T C

H

LI

N E

CAGED

STORAGE

OFFICE

TR ROOM

CORRIDOR

8' - 6" 40' - 0" 36' - 0" 32' - 0" 32' - 0"

8'

5'

8'

2'

1'

"Q.7

EL + 13'-0" TYP

EL + 12'-0" TYP

EL + 10'-0" TYP

EL + 9'-0"

CORRIDOR

EL + 8'-2"

EL + 8'-2"

EL + 8'-2"

EL + 9'-0"

EL + 9'-0"

EL + 9'-0"

EL + 9'-0"

8'

AAR

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :0

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:0

P M

P N

F

Y

/2

/2

AE127

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'L

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'L'

1. ALL 2 X 2 CEILING TILES THIS SHEET AT +9'-0" A.F.F. UNLESS

OTHERWISE NOTED

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

B. ALL 2 X 2 CEILING TILES THIS SHEET AT +9'-0" A.F.F. UNLESS OTHERWISE NOTED

C. ALL GYPSUM BOARD CEILINGS IN LATRINES, TOILET ROOMS, SHOWER AREAS, AND

MUD ROOMS SHALL BE CONSTRUCTED USING 5/8" TYPE "X" GLASS MAT GYPSUM

SHEATHING.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

2 12" X 12" ACCESS PANEL

3 24" X 24" ACCESS PANEL: BOTTOM AT +14'-4" A.F.F.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OS

OS

OS

OS

OS

OS

OS

DL

OS

OS

S S

OS

OS

OS

OS

OS

OS

OS

OS OS

P

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

17 18 19 20 21 22

C

D

E

F

G

J

H

A.8

AV

CORRIDOR

MAIN ELEC

OFFICE

NIPR CAFE

CAGED

STORAGE

STORAGE

AAR

SIPR TR

ELEC

STORAGE

RECYCLED

STORAGE

STORAGE

FIRE PUMP

STAIR

CAGED

STORAGE

CORRIDOR

M A

T C

H

LI

N E

MATCHLINE

CAGED

STORAGE

OFFICE

CAGED

STORAGE

8'

8'

9'

0"

8'

8' - 6" 40' - 0" 36' - 0" 32' - 0" 32' - 0"

H.2

EL + 10'-0"

EL + 9'-0"

EL + 9'-0"

EL + 9'-0"

EL + 9'-0"

B

EL + 9'-0"

EL + 9'-0"

EL + 14'-3"

AE412

C2

1/

8"

/4

/4

/4

/4

/4

1/

8"

8'

1/ 2"

8'

MECHANICAL

AAR

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :0

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:0

P M

P N

F

Y

/2

/2

AE128

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'M

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'M'

CEILING PLAN LEGEND

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

O S

OS

O S

DL

S

C

22 23 25 27 28 29 31

J

K

L

M

N

Q

P

26 30

Q.1

RTOC

CORRIDOR

TR ROOM

RTOC

RTOC

RTOC

RTOC

RTOC

ELEC.ROOM

MATCHLINE

M A

T C

H

LI

N E

CORRIDOR

32' - 0" 22' - 0" 10' - 0" 11' - 0" 21' - 0" 32' - 0" 32' - 0" 12' - 7" 19' - 5"

8'

5'

8'

2'

1'

"8'

Q.7

EL + 13'-0" TYP

EL + 12'-0" TYP

EL + 10'-0" TYP

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

LIGHT FIXTURES

EXIT LIGHT (CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CL CL

CL

CL

OSDL OS

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :1

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:1

P M

P N

F

Y

/2

/2

AE129

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'N

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE

1/8" = 1'-0"

PARTIAL CEILING PLAN - AREA 'N'

CEILING PLAN GENERAL NOTES CEILING PLAN LEGEND

KEY PLAN

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

1 OPEN TO SKYLIGHT ABOVE

2 24" X 24" ACCESS PANEL IN SOFFIT FASCIA : BOTTOM AT +14'-4" A.F.F.

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

OS OSDL

S S

OS

OS

P

22 23 25

C

D

E

F

G

J

H

TR ROOM

ELEC.ROOM

DISINTEGRATOR

TRAINING

SUPPLY

STORAGE

MATCHLINE

M A

T C

H

LI

N E

CORRIDOR

STORAGE

0"

8'

8'

9'

0"

8'

32' - 0" 22' - 0" 10' - 0" 11' - 0"

H.2

B

2' X 2' ACOUSTICAL TILE LAY-IN CEILING

GWB CEILING / SOFFIT

S

V F

CL CL

CL

CL

LIGHT FIXTURES

EXIT LIGHTS

(WALL AND CEILING MOUNTED)

MECHANICAL DIFFUSERS, FAN COIL

UNITS AND EQUIPMENT

SMOKE DETECTOR

POLYSTYRENE PLASTIC LOUVRE

GALVANIZED METAL

CHANNEL STRUT

FIRE PROTECTION SYMBOLS

VARIOUS SENSORSOS

ACOUSTICAL LINEAR WOOD PANEL SYSTEM

CURVED POLYCARBONATE

DL

CAMERAC

1 2 3 4 5

C

D

B

A

US Army Corps of Engineers

Fort Worth District

M ai n S tr ee t S ui te

V irg in ia

B ea ch , V

A

7.

5.

SHEET

REFERENCE

NUMBER

C o n tr N o W

H

P -1

-D

-0

C O

R P

S O

F E

N G

IN

E

E R

S

F O

R T

W

O R

T H

T

E X

A S

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T

R

IC

T

D w n b y:

D e si g n e d b y:

R e vi e w e d b y:

D a te

S u b m itt e d b y:

S o l N o

C o n tr

N o

R e v.

F ile n a m e

W H

P -1

-D

-0

C

R e v it P ro je c ts

\5 M

T C

F t

H o o d A c w h e e le r.

rv t /2

/2

:3 :1

P

M

C R e v it P ro je c ts

\5

M

T C

F t H o o d A c w h e e le r.

rv t

/2

/2

:3

:1

P M

P N

F

Y

/2

/2

AE130

P A

R T

IA

L C

E

IL

IN

G

P L A

N

A R

E A

'P

N W

S

J R

W

C E

W /G

J R

M

IS

S

IO

N T

R A

IN

IN

G C

O M

P L E

X

M T

C

F O

R T

H O

O D

T

E X

A S

1/8" = 1'-0"

AE130 - PARTIAL CEILING PLAN - AREA 'P'

1/8" = 1' - 0" 0 5' 10' 15' 30'

GRAPHIC SCALE

CEILING PLAN GENERAL NOTES

CEILING PLAN LEGEND

KEY PLAN

PLAN

NORTH

A

B

C

D

E

F

G

H

J

L

M

N

PK

A. COORDINATE FINAL ACCESS PANEL LOCATION WITH FINAL LOCATION OF

MECHANICAL EQUIPMENT.

KEYED NOTES

1 OPEN TO SKYLIGHT ABOVE

R E

V

D E

S C

R

IP

T

IO

N T

R A

C K

IN

G

A

C T

IO

N

D A

2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 27 28 29 31

C

D

E

F

G

J

K

L

M

N

R

Q

S

U

V

W

X

Y

Z

BB

CC

DD

H

T

AA

P

26 30

EE

Q.1

U.1

A.4

A.8

Q.7

H.2

B

14…

This is the start of the file's text. The full file is on GovTribe.