GP5_Site_Electrical_Layout.pdf
PDF 60 KB Posted
- Attached to
- Skid Mounted Environmental Equipment (SMEE)
- Solicitation number
- W9124R-18-T-0002
About this file
Electrical Layout
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Answers_8.docx | DOCX document | |
| Attachment_1_-_Minimum_Specifications_Revised_1-9-18.pdf | ||
| Answers_7.docx | DOCX document | |
| Answers_6.pdf | ||
| Answers_5.pdf | ||
| Answers_4.docx | DOCX document | |
| Answers_3.pdf | ||
| Attachment_1_-_Minimum_Specifications_Revised_12-14-17.pdf | ||
| Answers_2.DOCX | DOCX document | |
| CoN_CheckList_-_Redacted.pdf | ||
| Answers_1.docx | DOCX document | |
| Attachment_2_-_Clauses_and_Provisions.pdf | ||
| Attachment_3_-_Site_Visit_Information.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
82'-0"
62'-0"
30'-0"
22'-0"
7'-0"
13'-6"
12'-5"
25'-6"
4'-6"
35'-6"
24'-6"
7'-0"
13'-6"
7'-0"
12'-6"
24'-6"
NORTH
EAST
WEST
NOTES:
ALL * DESIGNATE POWER OR CONTROL 1.
CONDUIT ATTACHMENT POINTS ON
CONCRETE PAD. SEE SHEET 2 FOR
DETAILS
CONTROL ROOM LOCATED 108 FT 2.
NORTH OF PAD.
Balloon Number Power Specifications
Conduit Diameter
1 480V, 400A, 3PH 4.0"
2 Control Wire 2.0" 3 Control Wire 2.0"
4 480V, 600A, 3PH 4.0"
5 Control Wire 2.0"
6 480V, 400A, 3PH 4.0"
A A
B B
DO NOT SCALE DRAWING SHEET 1 OF 2
11/2017GWR
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:300
REVDWG. NO.
A
SIZE
TITLE:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/64
ANGULAR: MACH BEND
TWO PLACE DECIMAL .01
THREE PLACE DECIMAL .001
APPLICATION
USED ONNEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
U.S. ARMY YUMA PROVING GROUND
YUMA, ARIZONA 85365
GP5 Concrete Pad Electrical Power Location
Overview
2017339 garry.w.rosene.civ Text Box
FOR REFERENCE ONLY
FINAL DIMENSIONS TO BE VERIFIED AND CONFIRMED BY VENDOR PRIOR TO COMMENCING WORK
7'-0" 35'-6"
7'-0"
13'-6"
82'-0"
62'-0"
30'-0"
4" CONDUIT
2" CONDUIT
4" CONDUIT
4" CONDUIT
2" CONDUIT
1-1/2" CONDUIT
2" CONDUIT
2" CONDUIT TO LEFT SIDE
PLUG ECS CONTROL ROOM
1-1/2" CONDUIT TO LEFT
SIDE PLUG ECS CONTROL
ROOM
1-1/2" CONDUIT TO CENTER
PLUG ECS CONTROL ROOM
2" CONDUIT TO CENTER
PLUG ECS CONTROL ROOM
A A
B B
DO NOT SCALE DRAWING SHEET 2 OF 2
11/2017GWR
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:185
REVDWG. NO.
A
SIZE
TITLE:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/64
ANGULAR: MACH BEND
TWO PLACE DECIMAL .01
THREE PLACE DECIMAL .001
APPLICATION
USED ONNEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
U.S. ARMY YUMA PROVING GROUND
YUMA, ARIZONA 85365
GP5 Concrete Pad Electrical Power Location
Overview
2017339 garry.w.rosene.civ Text Box
FOR REFERENCE ONLY
FINAL DIMENSIONS TO BE VERIFIED AND CONFIRMED BY VENDOR PRIOR TO COMMENCING WORK
| Sheet1 |
| Drawing View1 |
| Sheet2 |
| Drawing View2 |
File details come from the government source that posted it.