GP5_Site_Electrical_Layout.pdf

PDF 60 KB Posted

Attached to
Skid Mounted Environmental Equipment (SMEE)
Solicitation number
W9124R-18-T-0002
Issued by

About this file

Electrical Layout

View the file

Other files

File Type Posted
Answers_8.docx DOCX document
Attachment_1_-_Minimum_Specifications_Revised_1-9-18.pdf PDF
Answers_7.docx DOCX document
Answers_6.pdf PDF
Answers_5.pdf PDF
Answers_4.docx DOCX document
Answers_3.pdf PDF
Attachment_1_-_Minimum_Specifications_Revised_12-14-17.pdf PDF
Answers_2.DOCX DOCX document
CoN_CheckList_-_Redacted.pdf PDF
Answers_1.docx DOCX document
Attachment_2_-_Clauses_and_Provisions.pdf PDF
Attachment_3_-_Site_Visit_Information.docx DOCX document
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

82'-0"

62'-0"

30'-0"

22'-0"

7'-0"

13'-6"

12'-5"

25'-6"

4'-6"

35'-6"

24'-6"

7'-0"

13'-6"

7'-0"

12'-6"

24'-6"

NORTH

EAST

WEST

NOTES:

ALL * DESIGNATE POWER OR CONTROL 1.

CONDUIT ATTACHMENT POINTS ON

CONCRETE PAD. SEE SHEET 2 FOR

DETAILS

CONTROL ROOM LOCATED 108 FT 2.

NORTH OF PAD.

Balloon Number Power Specifications

Conduit Diameter

1 480V, 400A, 3PH 4.0"

2 Control Wire 2.0" 3 Control Wire 2.0"

4 480V, 600A, 3PH 4.0"

5 Control Wire 2.0"

6 480V, 400A, 3PH 4.0"

A A

B B

DO NOT SCALE DRAWING SHEET 1 OF 2

11/2017GWR

UNLESS OTHERWISE SPECIFIED:

SCALE: 1:300

REVDWG. NO.

A

SIZE

TITLE:

NAME DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

INTERPRET GEOMETRIC

TOLERANCING PER:

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/64

ANGULAR: MACH BEND

TWO PLACE DECIMAL .01

THREE PLACE DECIMAL .001

APPLICATION

USED ONNEXT ASSY

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

<INSERT COMPANY NAME HERE>. ANY

REPRODUCTION IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF

<INSERT COMPANY NAME HERE> IS

PROHIBITED.

U.S. ARMY YUMA PROVING GROUND

YUMA, ARIZONA 85365

GP5 Concrete Pad Electrical Power Location

Overview

2017339 garry.w.rosene.civ Text Box

FOR REFERENCE ONLY

FINAL DIMENSIONS TO BE VERIFIED AND CONFIRMED BY VENDOR PRIOR TO COMMENCING WORK

7'-0" 35'-6"

7'-0"

13'-6"

82'-0"

62'-0"

30'-0"

4" CONDUIT

2" CONDUIT

4" CONDUIT

4" CONDUIT

2" CONDUIT

1-1/2" CONDUIT

2" CONDUIT

2" CONDUIT TO LEFT SIDE

PLUG ECS CONTROL ROOM

1-1/2" CONDUIT TO LEFT

SIDE PLUG ECS CONTROL

ROOM

1-1/2" CONDUIT TO CENTER

PLUG ECS CONTROL ROOM

2" CONDUIT TO CENTER

PLUG ECS CONTROL ROOM

A A

B B

DO NOT SCALE DRAWING SHEET 2 OF 2

11/2017GWR

UNLESS OTHERWISE SPECIFIED:

SCALE: 1:185

REVDWG. NO.

A

SIZE

TITLE:

NAME DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

INTERPRET GEOMETRIC

TOLERANCING PER:

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/64

ANGULAR: MACH BEND

TWO PLACE DECIMAL .01

THREE PLACE DECIMAL .001

APPLICATION

USED ONNEXT ASSY

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

<INSERT COMPANY NAME HERE>. ANY

REPRODUCTION IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF

<INSERT COMPANY NAME HERE> IS

PROHIBITED.

U.S. ARMY YUMA PROVING GROUND

YUMA, ARIZONA 85365

GP5 Concrete Pad Electrical Power Location

Overview

2017339 garry.w.rosene.civ Text Box

FOR REFERENCE ONLY

FINAL DIMENSIONS TO BE VERIFIED AND CONFIRMED BY VENDOR PRIOR TO COMMENCING WORK

Sheet1
Drawing View1
Sheet2
Drawing View2

File details come from the government source that posted it.