j26_Trial_Proposal_Drawings.pdf

PDF 2 MB Posted

Attached to
Job Order Contract (JOC) - Construction Federal contract opportunity
Solicitation number
W9124P-16-R-0006
Issued by
Department of the Army Materiel Command Aviation and Missile Life Cycle Management Command

About this file

j26 - Trail Proposal Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Job Order Contract (JOC) - Construction, newest first.
File Type Posted
W9124P-16-R-0006_AMD_02.pdf PDF
JOC_QUESTIONS_ _RESPONSES_-_W9124P-16-R-0006.pdf PDF
Building_5201_ROOF_RECOVER_SOW__SPEC_rev_1.pdf PDF
Redstone_Building_5201_Shop_Drawings_rev_1.pdf PDF
APPENDIX_A.pdf PDF
W9124P-16-R-0006_AMD_01.pdf PDF
j3_JOC_112M_ENVIROLAWS.doc DOC document
j25_cdrls_signed.pdf PDF
j8qcreport.xls XLS spreadsheet
j7cityincenerator.doc DOC document
j9sitevisit.doc DOC document
j20_ppsurvey.docx DOCX document
j13_cc_order_form.xlsx XLSX spreadsheet
j23_specialexp.docx DOCX document
j19pprecord.doc DOC document
5201-2015344-14_Roof_Replacement_SOW_ _Specs_40_yr.pdf PDF
j10progchart.xls XLS spreadsheet
j2_JOC_112M_HAZWASTE_PLAN.doc DOC document
J18_-_JOC_SPILLPLAN.doc DOC document
j14septic.xls XLS spreadsheet
j4equipdata.xls XLS spreadsheet
j15nor498.xls XLS spreadsheet
j1turnin.xls XLS spreadsheet
j16bmpinspect500.xls XLS spreadsheet
5201-2015344-14_Roof_Replacemetn_40_yr_Garland_18x24_drawings.pdf PDF
j24_access.xlsx XLSX spreadsheet
5201-2015344-14_DPW_Roof_Plan.pdf PDF
j12joceval.xls XLS spreadsheet
j5swma.xls XLS spreadsheet
j21resume.docx DOCX document
j22commitment.docx DOCX document
j6citylandfill.doc DOC document
W9124P-16-R-0006_(8.24.2016).pdf PDF
j11equipwarranty.doc DOC document
112M_JOC_DRAFT_RFP.pdf PDF
JOC_PWS.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: �"=1’-0"

S. KRESAL

T. SMITH

B. BEST

J. RILEY

S P

E C

N

A

W

A .D

G N

PW-3545

i p p e n t a b l e d g n s p e c s y t i m e

BLDG. 3545

M. STOUT

220TQF/TN-41712

TECH ESCORT TRAINING

FACILITY

AS SHOWN

FEB. 2002

LEGEND AND NOTES

HVAC PLAN,

HVAC PLAN

EF-1

50 CFM

CFM

8x8

AIR

OUTSIDE

650 CFM

TO HAVE BIRDSCREEN

OUTSIDE AIR LOUVER

SUBMITTED

WILL VARY, DEPENDING ON UNIT

AND RETURN OPENINGS. THESE

PROPERLY FIT AHU DISCHARGE

DUCTS TO TRANSITION TO

MODIFY SUPPLY AND RETURN

AHU-1

1.

2.

3.

4.

5.

HVAC GENERAL NOTES:

6.

AC-1

8x8 SA 12x10 SA

SA

8x8

SA

8x8

SA

8x8

SA

8x8

12x14 SA 14x14 SA

40x20 SA

20x20 SA x

S

A

20x14 SA 12x14 SA 10x12 SA x x x

8x8 SA x

10x12 SA 12x18 SA 14x20 SA 14x20 SA 12x18 SA 10x12 SA

12x10 RA

44x20 RA 34x20 RA x

R

30x20 RA x

20x20 RA x x x

ELEVATION SECTION

LOUVER

EXHAUST DUCT

BIRDSCREEN

WALL EXHAUST FAN DETAIL

NOT TO SCALE

SIDING

METAL

DRIP

SYMBOL TYPE CFM DRIVE H.P.

ELECTRICAL DATA

VOLTS PHASE CYCLE

EF-1 DIRECT0.25 1/152600 115 60

16�" 14" 7"

H W D

EXTERNAL DIMENSIONS

300 1

INSULATION

WALL

DAMPER

GRAVITY

EXHAUST DUCT

INSECT SCREEN

EXHAUST FAN

CAULK

SIDING)

(MATCH

FLASHING

PREFINISHED

AROUND

CLOSING ALL

NEOPRENE

NOT TO SCALE

SUPPLY AIR DIFFUSER DETAIL

SUPPLY DUCT

FITTING W/DAMPER

SPIN-IN TAP

MAX. LENGTH 10’-0"

EXTERNAL INSULATION

FLEX DUCT WITH 2"

AND TO DIFFUSER

EXTEND TO RIGID DUCT

2" EXTERNAL INSULATION

CEILING

SUSPENDED

T-BAR TYPE

NECK

DIFFUSER W/ROUND

LAY-IN SUPPLY AIR

(TYPICAL)

NYLON DRAW BAND

NOT TO SCALE

INTAKE LOUVER DETAIL

& FLASHING

EXISTING GIRT

7.

8.

9.

10.

11.

INCHES

PRESSURE

STATIC

RPM

MOUNTED

EXTERIOR

EXHAUST FAN SCHEDULE

TURNED ON EVEN IF LIGHTS ARE OFF.

ALSO HAVE MANUAL ON/OFF SWITCH AS WELL AS AUTO MODE SO FANS MAY BE

RUN FOR A TEN MINUTE TIME PERIOD AFTER THE LIGHTS ARE TURNED OFF. FAN TO

MENS OR WOMENS LIGHTS ARE ON FAN SHALL BE RUNNING AND SHALL CONTINUTE TO

FAN OPERATION SHALL BE CONNECTED TO LIGHTS INSIDE OF RESTROOMS. WHEN THE

FAN SHALL BE PROVIDED WITH BACKDRAFT DAMPER AND ADUSTABLE EXHAUST GRILLES.

USE THIS MODEL OR APPROVED EQUAL.

FAN MODEL USED FOR DESIGN FROM GRAINGER CATALOG MODEL FANTECH RVF6XL.1.

2.

3.

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

B

CFM

CFM

CFM

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CPU-1

PAD

CONCRETE

3000 PSI

PIPE BOLLARDS

LIQUID LINES

SUCTION AND

FLEX CONNECTION

S.A.S.

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

T

F

F

CFM

A

CFM

A

CFM

CFM

CFM

A

CFM

A

CFM

A

SYMBOL TYPE

8.8

CAP. MBTU

GROSS COOLING

AHU

MATCHED

EER

(BELS)

RATING

SOUND

HVAC UNIT SCHEDULE

CONDENSING UNIT SPLIT SYSTEM

CPU-1 246

DUAL

COMPRESSOR

9.7

SYMBOL

AHU-1 1.5"

AIR HANDLING UNIT (AHU)

(H 0 GAGE)

PRESSURE

TOTAL STATIC

COIL CAPACITY

STEAM HEATING

390 MBH

CFM

USE THIS EQUIPMENT OR APPROVED EQUAL

TRANE AHU TWE 240 B3

TRANE CONDENSING UNIT TTA240 B3

UNIT USED FOR DESIGN:

1.

2.

NOTES:

TO MINIMIZE NOISE TRANSMISSION.

SUPPLY DUCT SHALL HAVE VIBRATION INSULATION CONNECTION

SETBACK THERMOSTAT. UNIT SHALL HAVE DUAL COMPRESSORS.

CONTROLS SHALL HAVE PROGRAMABLE ELECTRONIC NIGHT

ALL SUPPLY AND RETURN DIFFUSERS SHALL HAVE INTREGAL VOLUME AIR DAMPERS.

SHALL ALSO BE EQUIPPED WITH SUBBASE.

CONDENSING UNIT AND AIR HANDLER SHALL BE EQUIPPED WITH VIBRATION ISOLATORS. AIR HANDLER

OF UNIT SELECTED.

CONCRETE PAD FOR CONDENSING UNIT SHALL BE AT LEAST 6" LARGER THAN LENGTH AND WIDTH

COMPANY, PER DESIGN DRAWINGS.

DUCT WORK SUPPLY SYSTEM SHALL BE TESTED AND BALANCED BY AN APPROVED TEST & BALANCE

EQUAL TO THE FIRE WALL RATING.

FIRE WALL PENETRATIONS SHALL BE SEALED WITH AN APPROVED SEALING SYSTEM (AM F&T RATING)

RECOMMENDATIONS.

LIQUID AND SUCTION REFRIGERANT PIPING SHALL BE INSULATED PER MANUFACTURER

DETECTOR TROUBLE.

VISUALLY OR AUDIBLY IN A NORMALLY OCCUPIED AREA AND SHALL BE IDENTIFIED AS AIR DUCT

SIGNAL IN A NORMALLY OCCUPIED AREA. 2. SMOKE DETECTOR TROUBLE CONDITIONS SHALL INDICATE

FOLLOWING OCCUR: 1. SMOKE DETECTION ACTIVATION SHALL CAUSE A VISUAL AND AUDIBLE ALARM

A INDICATOR SWITCH TO INDICATE DETECTORS STATUS (PER NFPA 90A) AND SHALL MAKE THE

OF AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTION. DETECTOR SHALL BE CONNECTED TO

SMOKE DETECTOR SHALL BE INSTALLED IN SUPPLY DUCT AND LOCATED AS FOLLOWS: DOWNSTREAM

STRAIGHT RUNS ONLY.

IN THIS DUCTWORK SYSTEM, ALL ELBOWS SHALL BE HARD DUCT. FLEX DUCT SHALL BE FOR

FROM FLEX DUCT SHALL BE ALLOWED. FLEX ELBOWS SHALL NOT BE FABRICATED OR INSTALLED

EXCEED 3 FEET IN LENGTH IN ANY SINGULAR APPLICATION. NO 90 OR 45 DEGREE ELBOWS MADE

FLEX DUCT SHALL NOT BE USED FOR BRANCH LINES DUCT INSTALLATIONS. FLEX DUCT SHALL NOT

CALCULATIONS WAS USED IN THIS DESIGN.

0.1" OF WATER FOR SUPPLY DUCT CALCULATIONS AND 0.08" OF WATER FOR RETURN DUCT

UNIT BE SELECTED FOR THIS PROJECT, DUCT DIMENSIONS MAY HAVE TO BE MODIFIED. A VALUE OF

THESE SIZES ARE FOR THE PARTICULAR UNIT CHOSEN FOR DESIGN, SHOULD SOME OTHER TYPE OF

DUCTWORK SIZING WAS ACCOMPLISHED BY USING EQUAL FRICTION METHOD FOR DUCT DIMENSIONS.

WITH WEATHERPROOF JACKETING (FOR ALL EXTERIOR DUCT) UNLESS OTHERWISE NOTED.

INSULATE ALL NEW DUCTWORK WITH 2" THICK, FOIL BACKED, � LB DENSITY BLANKET INSULATION

BE PER SMACNA DUCT CONSTRUCTION STANDARDS, SEAL CLASS "C".

DUCT SIZES ARE SHOWN ON DRAWINGS ARE OUTSIDE DIMENSIONS. DUCTWORK CONSTRUCTION SHALL

AND STANDARDS.

FOR A COMPLETE AND OPERABLE SYSTEM SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES

IN THESE DRAWINGS SHALL BE STRICTLY CONFORMED TO. ALL MATERIAL AND LABOR REQUIRED

EQUIPMENT, APPURTENANCES, CONTROLS, AND ELECTRICAL CONNECTIONS. ALL PARAMETERS GIVEN

MODIFICATION BE A COMPLETE AND OPERABLE SYSTEM AND BE PROVIDED WITH ALL NECESSARY

(DO NOT SCALE DRAWINGS FOR LOCATIONS OR DIMENSIONS.) IT IS INTENDED THAT THIS HVAC

DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS.

12.

LEGEND

S.A.S.

T

F

F

A

B

SMOKE ALARM DETECTOR

THERMOSTAT

FIRE ALARM VISUAL

FIRE ALARM AUDIO

DIFFFUSER 4-WAY THROW

DIFFUSER 1-WAY THROW

OPPOSED BLADE BALANCING DAMPER

SUPPLY DIFFUSER

RETURN DIFFUSER

VOLUME EXTRACTOR (CONFIGURATION OR MECHANICAL)

HVAC UNIT

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

QUALITY ASSURANCEENERGYENVIRONMENTAL

CUSTOMER:

NOT TO SCALE

STEAM COIL

NON-FREEZE

UNIONL

P

S

UNION

C R

SERVICE VALVE

STRAINER

RETURN

CONDENSATE

TRAP

TRAP

STRAINER

SERVICE VALVE

CHECK VALVE

STEAM

LOW PRESSURE

M

IN

TYP. STEAM COIL PIPING DETAIL

SCALE: ‚"=1'-0"

HVAC PLAN

EF-1

50 CFM

CFM

8x8

AIR

OUTSIDE

650 CFM

TO HAVE BIRDSCREEN

OUTSIDE AIR LOUVER

SUBMITTED

WILL VARY, DEPENDING ON UNIT

AND RETURN OPENINGS. THESE

PROPERLY FIT AHU DISCHARGE

DUCTS TO TRANSITION TO

MODIFY SUPPLY AND RETURN

AHU-1

1.

2.

3.

4.

5.

HVAC GENERAL NOTES:

6.

8x8 SA 12x10 SA

SA

8x8

SA

8x8

SA

8x8

SA

8x8

12x14 SA 14x14 SA

40x20 SA

20x20 SA x

S

A

20x14 SA 12x14 SA 10x12 SA x x

8x8 SA x

10x12 SA 12x18 SA 14x20 SA 14x20 SA 12x18 SA 10x12 SA

12x10 RA

44x20 RA 34x20 RA x

30x20 RA x

20x20 RA x x x

SYMBOL TYPE CFM DRIVE H.P.

ELECTRICAL DATA

VOLTS PHASE CYCLE

EF-1 DIRECT0.25 1/152600 115 60

16ƒ" 14" 7"

H W D

EXTERNAL DIMENSIONS

300 1

7.

8.

9.

10.

11.

INCHES

PRESSURE

STATIC

RPM

MOUNTED

EXTERIOR

EXHAUST FAN SCHEDULE

TURNED ON EVEN IF LIGHTS ARE OFF.

ALSO HAVE MANUAL ON/OFF SWITCH AS WELL AS AUTO MODE SO FANS MAY BE

RUN FOR A TEN MINUTE TIME PERIOD AFTER THE LIGHTS ARE TURNED OFF. FAN TO

MENS OR WOMENS LIGHTS ARE ON FAN SHALL BE RUNNING AND SHALL CONTINUTE TO

FAN OPERATION SHALL BE CONNECTED TO LIGHTS INSIDE OF RESTROOMS. WHEN THE

FAN SHALL BE PROVIDED WITH BACKDRAFT DAMPER AND ADUSTABLE EXHAUST GRILLES.

USE THIS MODEL OR APPROVED EQUAL.

FAN MODEL USED FOR DESIGN FROM GRAINGER CATALOG MODEL FANTECH RVF6XL.1.

2.

3.

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

B

CFM

CFM

CFM

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CPU-1

PAD

CONCRETE

3000 PSI

PIPE BOLLARDS LIQUID LINES

SUCTION AND

FLEX CONNECTION

S.A.S.

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

A

CFM

T

F

F

CFM

A

CFM

A

CFM

CFM

CFM

A

CFM

A

CFM

A

SYMBOL TYPE

8.8

CAP. MBTU

GROSS COOLING

AHU

MATCHED

EER

(BELS)

RATING

SOUND

HVAC UNIT SCHEDULE

CONDENSING UNIT SPLIT SYSTEM

CPU-1 246

DUAL

COMPRESSOR

9.7

SYMBOL

AHU-1 1.5"

AIR HANDLING UNIT (AHU)

(H 0 GAGE)

PRESSURE

TOTAL STATIC

COIL CAPACITY

STEAM HEATING

390 MBH

CFM

USE THIS EQUIPMENT OR APPROVED EQUAL

TRANE AHU TWE 240 B3

TRANE CONDENSING UNIT TTA240 B3

UNIT USED FOR DESIGN:

1.

2.

NOTES:

TO MINIMIZE NOISE TRANSMISSION.

SUPPLY DUCT SHALL HAVE VIBRATION INSULATION CONNECTION

SETBACK THERMOSTAT. UNIT SHALL HAVE DUAL COMPRESSORS.

CONTROLS SHALL HAVE PROGRAMABLE ELECTRONIC NIGHT

ALL SUPPLY AND RETURN DIFFUSERS SHALL HAVE INTREGAL VOLUME AIR DAMPERS.

SHALL ALSO BE EQUIPPED WITH SUBBASE.

CONDENSING UNIT AND AIR HANDLER SHALL BE EQUIPPED WITH VIBRATION ISOLATORS. AIR HANDLER

OF UNIT SELECTED.

CONCRETE PAD FOR CONDENSING UNIT SHALL BE AT LEAST 6" LARGER THAN LENGTH AND WIDTH

COMPANY, PER DESIGN DRAWINGS.

DUCT WORK SUPPLY SYSTEM SHALL BE TESTED AND BALANCED BY AN APPROVED TEST & BALANCE

EQUAL TO THE FIRE WALL RATING.

FIRE WALL PENETRATIONS SHALL BE SEALED WITH AN APPROVED SEALING SYSTEM (AM F&T RATING)

RECOMMENDATIONS.

LIQUID AND SUCTION REFRIGERANT PIPING SHALL BE INSULATED PER MANUFACTURER

DETECTOR TROUBLE.

VISUALLY OR AUDIBLY IN A NORMALLY OCCUPIED AREA AND SHALL BE IDENTIFIED AS AIR DUCT

SIGNAL IN A NORMALLY OCCUPIED AREA. 2. SMOKE DETECTOR TROUBLE CONDITIONS SHALL INDICATE

FOLLOWING OCCUR: 1. SMOKE DETECTION ACTIVATION SHALL CAUSE A VISUAL AND AUDIBLE ALARM

A INDICATOR SWITCH TO INDICATE DETECTORS STATUS (PER NFPA 90A) AND SHALL MAKE THE

OF AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTION. DETECTOR SHALL BE CONNECTED TO

SMOKE DETECTOR SHALL BE INSTALLED IN SUPPLY DUCT AND LOCATED AS FOLLOWS: DOWNSTREAM

STRAIGHT RUNS ONLY.

IN THIS DUCTWORK SYSTEM, ALL ELBOWS SHALL BE HARD DUCT. FLEX DUCT SHALL BE FOR

FROM FLEX DUCT SHALL BE ALLOWED. FLEX ELBOWS SHALL NOT BE FABRICATED OR INSTALLED

EXCEED 3 FEET IN LENGTH IN ANY SINGULAR APPLICATION. NO 90 OR 45 DEGREE ELBOWS MADE

FLEX DUCT SHALL NOT BE USED FOR BRANCH LINES DUCT INSTALLATIONS. FLEX DUCT SHALL NOT

CALCULATIONS WAS USED IN THIS DESIGN.

0.1" OF WATER FOR SUPPLY DUCT CALCULATIONS AND 0.08" OF WATER FOR RETURN DUCT

UNIT BE SELECTED FOR THIS PROJECT, DUCT DIMENSIONS MAY HAVE TO BE MODIFIED. A VALUE OF

THESE SIZES ARE FOR THE PARTICULAR UNIT CHOSEN FOR DESIGN, SHOULD SOME OTHER TYPE OF

DUCTWORK SIZING WAS ACCOMPLISHED BY USING EQUAL FRICTION METHOD FOR DUCT DIMENSIONS.

WITH WEATHERPROOF JACKETING (FOR ALL EXTERIOR DUCT) UNLESS OTHERWISE NOTED.

INSULATE ALL NEW DUCTWORK WITH 2" THICK, FOIL BACKED, ƒ LB DENSITY BLANKET INSULATION

BE PER SMACNA DUCT CONSTRUCTION STANDARDS, SEAL CLASS "C".

DUCT SIZES ARE SHOWN ON DRAWINGS ARE OUTSIDE DIMENSIONS. DUCTWORK CONSTRUCTION SHALL

AND STANDARDS.

FOR A COMPLETE AND OPERABLE SYSTEM SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES

IN THESE DRAWINGS SHALL BE STRICTLY CONFORMED TO. ALL MATERIAL AND LABOR REQUIRED

EQUIPMENT, APPURTENANCES, CONTROLS, AND ELECTRICAL CONNECTIONS. ALL PARAMETERS GIVEN

MODIFICATION BE A COMPLETE AND OPERABLE SYSTEM AND BE PROVIDED WITH ALL NECESSARY

(DO NOT SCALE DRAWINGS FOR LOCATIONS OR DIMENSIONS.) IT IS INTENDED THAT THIS HVAC

DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS.

12.

HVAC UNIT

STEAM

FIBERGLASS INSUL.

STEAM LINE W/ 2"

1 1/2" LOW PRESSURE

W/ 2" FIBERGLASS INSUL.

1" CONDENSATE LINE

ARMAFLEX INSUL.

1 5/8" W/ 1"

ARMAFLEX INSUL.

5/8" W/ 1"

MASTER PLANNINGQUALITY ASSURANCEENERGYENVIRONMENTAL

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURAL

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

CUSTOMER:

S. KRESAL

T. SMITH

E C

N

A

D G

N

PW-3545

BLDG. 3545

M. STOUT

220TQF/TN-41712

TECH ESCORT TRAINING

FACILITY

AS SHOWN

FEB. 2002 AC-2

STEAM AND

CONDENSATE PIPING

FLOOR PLAN

TECH ESCORT TRAINING

FACILITY

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

QUALITY ASSURANCEENERGYENVIRONMENTALSECURITY

CUSTOMER:

R. BEEM

A. COLE

FEB 2002

P

E

R .D

G N

AS SHOWN PW-3545

AR-1

s y t i m e d g n s p e c i p p e n t a b l e

BLDG. 3545

3’-0" 3’-0"7’-0" 5’-0"

6’-0" 7’-7"

3’-0" 3’-0"

3’-0"

1’-0"

5’-2" 4’-6" 5’-0"4’-6" 5’-6" 2’-0" 9’-0" 4’-6" 7’-6" +++

8’-0"8’-0"

16’-2" 12’-0"

20’-6"8’-0"5’-0"

T Y

P

.8’-0" TYP.12’-10"

M I N

8’-0"

8’-0"

30’-11"

5’-0" 35’-1"4’-0" 29’-11"

8’-11"1’-0"

26’-0"

82’-0"

34’-7"34’-7" 10’-0"

1’-0" 1’-0"

M. STOUT

MEDIA RM.

CONF. RM.

OFFICE

CADRE ADMIN. AREA

MEN RM.

WOMEN RM.

ELEC. RM. COMM. RM.

VENDING

CLO.

FLOOR PLAN & WALL SECTION

220TQF/TN-41712

MAX.

21 20

MAX.

ANCHOR TO CONC. GRADE BEAM

AS PER BLDG. MFGR. (TYP.)

VAPOR BARRIER

.006" POLYETHYLENE

�" GYP. BD.

FLOOR FINISH-

SEE FINISH SCHEDULE

FINISHED GRADE

CLOSURE STRIPS, TYP.

4" 3000 P.S.I. CONC. SLAB

BLDG. MFGR.

SIZE & SPACING AS PER

BLDG. BENTS & PURLINS

SUSPENDED CEILING

WITH VINYL VAPOR BARRIER

2" GLASS FIBER INSULATION

TYP. EXTERIOR WALL SECTION

COMPACTED FILL

METAL BLDG. MFGR.

COLUMNS SIZED PER

CONCRETE FOOTING AT

SCALE: �" = 1’-0"

MASTIC SEALANT AS RECOMMENDED BY SIDING MANUFACTURED.

MINIMIZE OIL-CANNING EFFECT. ALLSEAMS SHALL BE SEALED WITH

PER ASTM A792-83. SIDING PANELS SHALL HAVE STRIATIONS TO

2 INCH DEEP RIB, PREFINISHED ALUMINUM-ZINC ALLOY COATED STEEL

METAL SIDING PANELS SHALL BE 24 GAUGE MINIMUM, 16 INCH WIDE,

METAL SIDING NOTES:

A792-83.

MINIMUM, PREFINISHED ALUMINUM-ZINC ALLOY COATED STEEL PER ASTM

FASCIA AND GUTTER SHALL BE SINGLE PIECE CONSTRUCTION, 24 GAUGE

BE PERMITTED.

LINES. WAVY, UNEVEN, UNLEVEL, OR LOOSE FLASHING EDGES SHALL NOT

ADEQUATELY SUPPORTED AND FASTENED TO PRODUCE CRISP, STRAIGHT

ALL FLASHINGS AND FASCIA ASSOCIATED WITH SIDING SYSTEM SHALL BE

1.

2.

3.

4.

5.

METAL ROOFING NOTES:

1.

2.

3.

LOOSE FLASHING EDGES SHALL NOT BE PERMITTED.

AND FASTENED TO PRODUCE CRISP, STRAIGHT LINES. WAVY, UNEVEN, UNLEVEL, OR

ALL FLASHINGS ASSOCIATED WITH ROOF SYSTEM SHALL BE ADEQUATELY SUPPORTED

COINCIDE WITH JOINTS IN FASCIA METAL.

SHALL ALLOW A � INCH GAP BETWEEN PIECES. JOINTS IN CHEAT SHOULD NOT

ALL CHEATS SHALL BE CONTINUOUS WITH LENGHTS NOT TO EXCEED 12 FEET AND4.

TO THE ATTENTION OF THE CONTRACTING OFFICER’S REPRESENTATIVE IMMEDIATELY.

ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL CONDITIONS SHALL BE BROUGHT

CONTRACTOR SHALL SITE VERIFY ALL RELEVANT DIMENSIONS OF EXISTING BUILDING.5.

COMPACT IN 4 INCH LAYERS TO ACHIEVE 95 PERCENT MINIMUM DENSITY.

GRADED/CRUSHED AGGREGATE SUITABLE FOR BASE MATERIAL, 4 INCH MINIMUM.

THE CLEARED AREA TO 95 PERCENT DENSITY. BACKFILL AND LEVEL WITH DENSE

EXCAVATE UNSUITABLE, UNSTABLE, OR UNCONSOLIDATED MATERIAL AND COMPACT1.

ALL CONCRETE SHALL ATTAIN A 28-DAY COMPRESSIVE STRENGTH OF 3000 PSI.2.

REINFORCING BARS SHALL MEET ASTM A615 GRADE 60.3.

4.

POSITION IN THE CENTER OF THE SLAB THROUGHOUT.

WELDED WIRE FABRIC SHALL MEET ASTM A497. FABRIC SHALL BE MAINTAINED IN5.

CONCRETE AND FOUNDATION NOTES:

ALLOWABLE VARIATION OF � INCH.

THE MINIMUM CONCRETE COVER OF REINFORCING BARS SHALL BE 3 INCHES WITH AN

REFERENCES:A.

1. NFPA 101, LIFE SAFETY CODE, 2000

2. UNIFORM BUILDING CODE, 1997

3. MILITARY HANDBOOK 1008-C, 1997

FIRE SAFETY DESIGN ANALYSIS:

B. FIRE PROTECTION PROVISIONS:

1. CONSTRUCTION TYPE: TYPE II, NON-RATED

3. HEIGHT AND AREA LIMITATIONS:

ACTUAL AREA: EXISTING 6,400 SF + NEW 5,084 SF= 11,484 SF

ACTUAL HEIGHT: 1 STORY

MAX. AREA TOTAL (NEW AND EXISTING): 12,000 SF

MAX. HIGHT: 1STORY

4. FIRE PROTECTION CRITERIA: NONE REQUIRED

5. FIRE WALLS: NONE REQUIRED

6 EXTERIOR WALL AND OPENING PROTECTION:

8. NUMBER FIRE EXITS REQUIRED: MIN. =2 PROVIDED =3

9. EGRESS CAPACITY:

10. REMOTE/SEPARATE PATH OF TRAVEL IS MET

11. REMOTE/DIAGONAL RULE IS MET

14. TRAVEL DISTANCE: MAX. = 200 FT.; ACTUAL = 62 FT.

15. EXIT HARDWARE: NOT REQUIRED

17. EMERGENCY LIGHTING: NOT REQUIRED

21. LOCATION OF FIRE EXTINGUISHER(S):

ACTUAL: MAX. TRAVEL DISTANCE = 50 FT.

REQUIRED: MAX. TRAVEL DISTANCE = 75 FT.

TYP.

FOIL BACKING,

INSULATION W/

6" GLASS FIBER

INSULATION, TYP.

3�" GLASS FIBER R-13

ADJACENT BLDG.

TO MATCH EXIST.

METAL SIDING

PREFINISHED

ADJACENT BLDG.

DS TO MATCH EXIST.

MFGRS. STD. GUTTER &

TYP. ENTIRE LENGTH

VENTED RIDGE CAP

6 x 6 x W2.0 x W2.0

WELDED WIRE FABRIC, TYP.

4" COMPACTED CRUSHED ROCK

ALL AROUND

(2) #5 BAR, TYP.

AT COLUMN FOOTINGS

ADDITIONAL (3) #5 BAR, TYP.

SPLASH BLOCK

PRECAST CONC

M I N

2.

(CLASSROMS INCIDENTAL TO OCCUPANCY)

OCCUPANCY: NEW BUSINESS, SINGLE TENANT,

ACTUAL: >20 FT. FROM ADJACENT PROPERTY

REQUIRED: WHEN <20 FT. FROM ADJACENT PROPERTY

12. DEAD END CORRIDORS: 20 FT. MAX.

18. SPRINKLER SYSTEM: NOT REQUIRED

T

Y P

3’-0" 6’-11"

3’-0"3’-0"3’-0"3’-0" 6’-0" 6’-0" 5’-1"

20’-0" TYP.

(N.I.C.)

CUBICLE WALLS

NOTE 2

WALL TYPE

NOTE 3

WALL TYPE

MECH. RM.

TEL.

CORRIDOR "A"

CORRIDOR "B"

(N.I.C.) (N.I.C.)

NOTE 1

WALL TYPE

CLASS RM. 2

CLASS RM. 1

28’-7"

20’-0" TYP.

CONTRACTING OFFICER’S REPRESENTATIVE.

SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE

CONDITIONS. ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL

CONTRACTOR SHALL SITE VERIFY ALL RELEVANT DIMENSIONS AND

EXISTING CONCRETE SIDEWALK

SIDEWALK

EXISTING CONCRETE

EXISTING BUILDING

SCALE: �" = 1’-0"

THIS LINE

TO EXISTING ALONG

ALIGN NEW BUILDING

DETAILS

POWER PLAN FOR

SEE ELECTRICAL

FLOOR BOXES, TYP.

ELECT./DATA

FLASHINGS, DOWNSPOUTS, AND FASCIA/GUTTER SHALL BE WHITE.

MCBI, ATLANTA, GA. OR APPROVED EQUAL. COLOR OF SIDING PANELS,

SIDING PANELS SHALL BE ARTISAN L-12B AS MANUFACTURED BY

7 8

WALL TYPE NOTES:

1.

2.

3.

1’-0"

SLAB AT FLOOR BOXES

TYPICAL THICKENED

C L

A S

S R

O O

M

C O

R R I D

O R

"B

O

N L

Y

6’-0"6’-0"6’-0" 6’-0"7’-7" 6’-0"

COUNTER

LAMINATED

FIN. FLR. ELEV. = 652.5

FIN. FLR. ELEV. = 651.5

28’-4" +( )

SEE NOTE 4

WALL TYPE

BOARD, SOUTH WALL MEDIA ROOM ONLY.

�" CDX PLYWOOD ON METAL STUDS COVERED WITH �" GYPSUM4.

20. FIRE ALARM SYSTEM: NOT REQUIRED

19. APPROPRIATE MARKING OF EGRESS: NOT REQUIRED

16 NORMAL EGRESS ILLUMINATION REQUIREMENT: REQUIRED AND PROVIDED

13. COMMON PATH OF TRAVEL: 50 FT. MAX.

7. OCCUPANT LOAD: CLASSROOMS = 1960 SF./ 20 = 98/2 = 49

REMAINDER = 3124 / 100 = 32

TOTAL OCCUPANCY = 98 + 32 = 130

NEW CONCRETE SIDEWALK AND STEPS

FLOOR DRAIN.

SEE PLUMBING SHEET FOR SLOPE DIRECTION OF BATHROOM FLOORS TOWARD6.

PROVIDED: (36 IN. x 2 = 72 IN.) + (32 IN. x 1 = 32)= 104 IN.

REQUIRED: 130 PERSONS x 0.2 IN. = 26 IN.

STUDS, 3�" FIBERGLASS BATT INSULATION, NO KRAFT PAPER.

TYPICAL INTERIOR WALLS-�" GYPSUM BOARD BOTH SIDES, 25 GAUGE 3�" METAL

INTERIOR.

STUDS, 3�" FIBERGLASS BATT INSULATION, KRAFT PAPER TOWARD

TYPICAL EXTERIOR WALLS-�" GYPSUM BOARD ONE SIDE, 25 GAUGE 3�" METAL

WALLS TO ROOF, ALL PENETRATIONS SEALED.

FIBERGLASS BATT INSULATION, KRAFT PAPER TOWARD MECH. RM.

STUDS WITH RESILIENT CHANNEL MECH. RM. SIDE, AND 3�"

MECH. ROOM WALLS-�" GYPSUM BOARD BOTH SIDES, 25 GAUGE 3�" METAL

AREA EACH LOUVER

MIN. OF 5 SF. NET

TYP. EACH END WALL

GABLE-END LOUVERS

ROOFING, WHITE

STANDING SEAM

PREFINISHED METAL

O F

F I C

E S

B A

T H

R O

O M

S

A

D

O

R R I D

O R

"A

AT 16" O.C. TYP.

3�" 25 GA. METAL STUDS

1’-0"

4"

TYP.

CABINET

FIRE EXTINGUISHERVCT-1 VCT-2

COPY RM.

CABINET

FIRE EXTINGUISHER

DRINKING COOLER

ACCESSIBLE

HANDICAPPED

12"

(2) 6" RISERS

BE 24 GAUGE MINIMUM AND BY THE SAME MANUFACTURER AS ROOF PANELS.

MANUFACTURER. ALL ASSOCIATED FLASHING, FASCIA/GUTTER, AND CLEATS SHALL

SEAMS SHALL BE SEALED WITH MASTIC SEALANT AS RECOMMENDED BY ROOFING

HAVE STRIATIONS BETWEEN MAJOR RIBS TO MINIMIZE OIL-CANNING EFFECT. ALL

ALUMINUM-ZINZ ALLOY COATED STEEL PER ASTM A792-83. ROOF PANELS SHALL

STANDING SEAM METAL ROOFING PANELS SHALL BE 24 GAUGE MINIMUM, PREFINISHED

FLASHINGS, DOWNSPOUTS, AND FASCIA/GUTTER SHALL BE WHITE.

MBCI, ATLANTA, GA OR APPROVED EQUAL, COLOR OF ROOF PANELS,

ROOF PANELS SHALL BE BATTON-LOC WITH 2" RIB AS MANUFACTURED BY

GRAB BARS

WINDOW, TYP.

REAR PROJECTION

FACILITY

SCALE: �" = 1’-0"

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

QUALITY ASSURANCEENERGYENVIRONMENTALSECURITY

CUSTOMER:

R. BEEM

A. COLE

FEB 2002

P

E

R .D

G N

AS SHOWN PW-3545

AR-2

s y t i m e d g n s p e c i p p e n t a b l e

M. STOUT

MEDIA RM.

CONF. RM.

OFFICE

CADRE ADMIN. AREA

MEN RM.

WOMEN RM.

ELEC. RM. COMM. RM.

VENDING

COPY/STORAGE

CLO.

220TQF/TN-41712

REFLECTED CEILING PLAN

MECH. RM.

CORRIDOR "B"

CORRIDOR "A"

EXISTING BUILDING

12’-0"14’-0"

REFLECTED CEILING PLAN

FINISH SCHEDULE:

CARPET (C)

RICHMOND

VINYL COMP. TILE (VCT

ARMSTRONG

VINYL WALL BASE (VWB)

FLEXCO

PAINT (P)

SHERWIN-WILLIAMS

PLASTIC LAMINATE (PL)

FORMICA

ACOUSTIC CEILING TILE (ACT)

US GYPSUM CO.

C-1

VCT-1

VCT-2

VWB-1

P-1

P-2

PL-1

ACT-1

ACT-2

(OFFICE AND CONFERENCE ROOMS ONLY)

#342 AUBURN (WITH ENHANCER III)

V979 COFFEE

V-972 FOSSIL

(REMINDER OF BUILDING)

ACCENT TILE

FIELD TILE

(ALL WALLS, ENTIRE BUILDING)

WF-037 DARK BEIGE

(METAL DOORS, FRAME, AND ACCENTS)

SW 1090 CRAFT BROWN SEMIGLOSS

(ALL WALLS, ENTIRE BUILDING)

SW 1088 ONLY NATURAL SATIN

(BOTH BATHROOM COUNTERS)

#7264-58 LIME STONE MATTE

(REMAINDER OF BUILDING)

#56704 NATURAL FISSURED II (2 FT X 2 FT)

(BOTH CLASSROOMS)

#56705 NATURAL FISSURED II (2 FT X 4 FT)

NECESSARY TO MEET THIS PROJECT’S MINIMUM REQUIREMENTS.

MANUFACTURER, BUT RATHER AN INDICATION OF COLOR, TEXTURE, AND QUALITY

FINISH SCHEDULE ITEMS ARE NOT TO BE CONSTRUED TO LIMIT ANY ITEM BY BRAND OR

VENDING) TO BE 8’-0" HIGH

WITHOUT DOORS (EXCEPT

ALL OPENINGS ON CORRIDOR

C L

A S

S R

O O

M

C O

R R I D

O R

"A

C O

R R I D

O R

"B

AR-2

SECTION

SCALE: �" = 1’-0"

CEILING HEIGHT

REMAINDER OF BUILDING - 9 FEET

CORRIDOR - 8 FEET

CLASSROOMS - 10 FEET

CLASS RM. 1 CLASS RM. 2

LIGHT FIXTURE

LAY-IN FLOURESCENT

LIGHT FIXTURES

CAN FLOURESCENT

FLUSH MOUNTED

LIGHT FIXTURE

FLOURESCENT

WALL MOUNTED

L E G E N D

AND VENDING

COPY/STORAGE,

COMM. ROOM,

AT ELECT. ROOM,

AS REQUIRED, TYP.

FROM 2’ x 4’ TILES

CUT EDGE TILE

SPECIFICATIONS

SEE ELECTRICAL SHEETS FOR LIGHT FIXTURE

NOTE:

5’-0"

5’-0"

CANOPY, TYP.

WHITE ALUMINUM

PREFINISHED

CANOPY, TYP.

WHITE ALUMINUM

PREFINISHED

5’-0"

CANOPY, TYP.

WHITE ALUMINUM

PREFINISHED

WINDOWS W-1

GLASS OUTER PANE �" GLASS, SINGLE HUNG MOVEMENT

GLASS UNITS, INNER PANE TO CONSIST OF �" LAMINATED

3’-0" x 5’-0", VINYL CLAD ALUMINUM, WHITE WITH INSULATED

WINDOWS COVERINGS WC-1 �" ALUMINUM WINDOW BLINDS, OFF-WHITE

SOUTH ELEVATION EAST ELEVATION

WEST ELEVATIONNORTH ELEVATION

SCALE: �" = 1’-0"

SCALE: �" = 1’-0" SCALE: �" = 1’-0"

SCALE: �" = 1’-0"

AND FINISHED SYSTEM, TYP.

FASTENERS, COMPRISING A COMPLETE

AND MISC. HARDWARE, SEALANTS, AND

DOWNSPOUTS, SUPPORTS, FLASHINGS,

RIBBED 24 GAUGE, WITH GUTTER,

PREFINISHED WHITE ALUMINUM CANOPY,

TILE CLASSROOMS ONLY

2’ x 4’ LAY-IN CEILING

TILE REMAINDER OF BLDG.

2’ x 2’ LAY-IN CEILING

8’ L x 8’ W

PROJECTION SCREEN

CONCEALED FRONT

OFFICE

A. COLE

E C

N

R .D

G N

PW-3545

AR-3

i p p e n t a b l e d g n s p e c s y t i m e

BLDG. 3545

M. STOUT

220TQF/TN-41712

TECH ESCORT TRAINING

FACILITY

AS SHOWN

FEB. 2002

HARDWARE SCHEDULE

T

Y P

2" TYP.

6" 5"

3'-6"

3'-0"

2'-0" 6"

3'-6" 3'-0"

6'-0" 1'-8"

6'-0" 1'-8"

2'-0"

6"7

TYP.

WIRE GLASS,

‚" CLEAR

LOUVERS

ADJUSTABLE

FRAME TYPE 1 FRAME TYPE 2 DOOR TYPE A DOOR TYPE B DOOR TYPE C DOOR TYPE D

FRAME TYPE 3 FRAME TYPE 4 DOOR TYPE E DOOR TYPE F

HARDWARE SET NO. 1

SET WEATHERSTRIPPING

EA. THRESHOLD, J36130

EA. CLOSER, MODERN TYPE, C02021, PT 4C 4D 4G 4H

LEVER ENTRANCE, KEYED ALIKE TO ADJACENT BUILDING

EA. EXIT DEVICE, TYPE 3, F08, GRADE 1, DEADLOCKING LATCHBOLT,

EA. BUTT HINGES, 4•" x 4•", A2112, NRP

(1)

(3)

HARDWARE SET NO. 2

HARDWARE SET NO. 3

(2)

(6)

EA. THRESHOLD, J36130

EA. CLOSER, C02061, PT 4C 4D 4G 4H

BRUSHED ALUMINUM TYP.

EA. LOCKSET, SERIES 1000, F04, GRADE 1 LEVER HANDLE,

HARDWARE SET NO. 4

EA. DOOR STOP, L02141

EA. LOCKSET, SERIES 4000, F82, GRADE 1, LEVER HANDLE

EA. BUTT HINGES, 4•" x 4•", A8133

HARDWARE SET NO. 5

EA. DOOR STOP, L02141

EA. LOCKSET, SERIES 4000, F84, GRADE 1, LEVER HANDLE

HARDWARE SET NO. 6

EA. FLOOR MTD. DOOR STOP, L02141

EA. KICKPLATES, J102, 10" STAINLESS STEEL

EA. PULL HANDLE, J405, STAINLESS STEEL

EA. PUSH PLATE, J301, STAINLESS STEEL

PT 4D 4F 4H, WITH HOLD OPEN

EA. CLOSER, MODERN TYPE, INTERIOR MTD., C02051,

EA. BUTT HINGES, 4•" x 4•", A8112

HARDWARE SET NO. 7

BRUSHED ALUMINUM, TYP.

EA. LOCKSET, SERIES 4000, F86, GRADE 1, LEVER HANDLE,

DOOR SCHEDULE

MARK

DOOR

SYMBOL

DOOR

WIDTH

SIZE

HEIGHT THICK.

MATERIAL TYPE GLASS MATERIAL TYPE

FRAME

ENTRY

ENTRY

ENTRY

MEDIA

3'-0"

3'-6"

3'-0"

6'-0"

3'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

A 1

LOCATION

HDW. SET

ENTRY

ENTRY

MECH.

MEDIA

CLASSRM.

MEDIA

CLASSRM.

OFFICE

OFFICE

CONF.

COPY

MEN

CHASE

CLOSET

WOMEN

COMM.

ELECT.

3'-6"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

3'-0"

1'-8"

3'-0"

3'-0"

3'-0"

3'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

7'-0"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

1ƒ"

METAL WIRE METAL 1

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

B

B

A

B

E

C

C

B

C

B

C

C

C

D

D

F

D

D

D

D

WIRE

WIRE

WIRE

WIRE

WIRE

WIRE

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

METAL

DOOR SCHEDULE AND

STD-128

SEE SHT.

SIGN

C

F

1•" METAL PIPE - SEE CORRIDOR GATE NOTE, THIS SHEETGATE 22 3'-8" 2'-0"

HARDWARE

HARDWARE SET NO. 8

EA. BUTT HINGES, 4•" x 4•", A8112

EA. CLOSER, MODERN TYPE, INTERIOR MTD., C02051,

PT 4D 4F 4H, WITH HOLD OPEN

EA. KICKPLATES, J102, 10" STAINLESS STEEL

EA. LOCKSET, SERIES 4000, F37, GRADE 1, LEVER HANDLE

IN NORMAL USE.

WITH SPRING HINGES TO SHUT AND LATCH CONSISTANTLY

DETAIL 1, THIS SHEET. IT SHALL BE MOUNTED ON WALL

THIS GATE CONSISTS OF 1•" METAL PIPE AS SHOWN AT

FIRE SAFETY DESIGN.

USE. IT IS AN INTEGERAL PART OF THIS BUILDING'S

THIS GATE MUST REMAIN LATCHED WHEN NOT IN ACTUAL

CORRIDOR GATE NOTES:

1.

2.

BATHROOM ACCESSORY SCHEDULE:

(1) JANITOR'S DEEP SINK WITH FAUCETT

(4) MIRRIOR, 36"X24", POLISHED PLATE GLASS, BEVELED EDGE

(4) SOAP DISPENSER FROM FAUCET MANUFACTURER

(3) TOILET TISSUE DISPENSER

(4) TOWEL DISPENSER/WASTE RECEPTACLE

(2) URINAL, AMERICAN STANDARD WHITE

(3) TOILET, AMERICAN STANDARD WHITE

(4) SINK FAUCET, CHROME FINISH, SINGLE HANDLE

(4) LAVATORY SINK, AMERICAN STANDARD, WHITE

AND QUALITY NECESSARY TO MEET THIS PROJECTS MINIMUM REQUIREMENTS.

BRAND OR MANUFACTURER, BUT RATHER AN INDICATION OF COLOR, TEXTURE,

FINISH SCHEDULE ITEMS ARE NOT TO BE CONSTRUED TO LIMIT ANY ITEM BY

NOTE:

3'-8"

MIN.

WALL

CUBICLE

MECHANISM

LATCHING

HINGES

SPRING

AND PAINTED

PIPE, PRIMED

1•" STEEL

CORRIDOR GATE

SCALE: •" = 1'-0"

DETAIL

NOTE:

SHALL BE INSULATED.

ALL METAL DOORS

EA. THRESHOLD, J36190

EA. DOOR HOLDER, C18511

SET SURFACE BOLTS, L14161

EA. CLOSER, C02021, PT 4C

EA. LOCKSET, SERIES 1000, F08, GRADE 2

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

3"W

W

P

W

3"W

CAJUN DRIVE

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

QUALITY ASSURANCEENERGYENVIRONMENTALSECURITY

CUSTOMER:

R. BEEM

A. COLE

B. BEST

J. RILEY

FACILITY

FEB 2002 S

P

E C

N

SITE PLAN

C .D

G N

AS SHOWN PW-3545

C-1 s y t i m e d g n s p e c i p p e n t a b l e

PROJECT

AREA

BILL

GATE 1

GATE 3

GATE 2

GATE 5

GATE 10

GATE 9

GATE 7

P A

T T

M A R T

IN

R O

A D

R I D

E O

U T

R O

A D

GOSS

RD.

D O

D D

R D

BUXTON

RD.

REDSTONE RD.

GATE 8

INCINERATOR

SOLID WASTE

HUNTSVILLE

PIT AREA

BORROW

LANDFILL

INERT

NOT TO SCALE

REDSTONE ARSENAL LOCATION MAP

DRMO

FACILITY

K

IN

G F

IS

H E R

R

O A D

C A J

U

IV

E

S H

IL

L E

L A

G H

IR

C L

E

S H

IL

L E

L A

H

IR

C L

E

GRAY ROAD

J O

G G

IN

T

A

IL

35533555

S-3533

25 METER M-16

RIFLE/PISTOL

RANGE

CHEMICAL

TRAINING

PROJECT

SITE

W

W

3"W

W

6"

6"

W

W

6"W

6" W

FH

FH

SS 6"

MH

SS

8"

P

PP

P

P

P P

P P

W

S

S

S

2�"

2�" S

SCOPE OF WORK:

RELATED SITE PREPARATION AND GRADING, UTILITY DEMOLITION AND

FASTENERS, SEALANTS, AND MISCELLANEOUS ITEMS NECESSARY TO MAKE A

COMPLETE AND FINISHED BUILDING WITH PROPERLY WORKING SYSTEMS.

GENERAL NOTES:

ORDERING ANY MATERIALS OR BEGINNING ANY DEMOLITION OR INSTALLATION.

ANY DISCREPANCIES SHALL PROMPTLY BE BROUGHT TO THE ATTENTION OF THE

CONTRACTING OFFICER’S REPRESENTATIVE.

AND REGULATIONS AND FOLLOW ALL MANUFACTURER’S INSTRUCTIONS FOR THE

PROPER TRANSPORTATION, STORAGE, AND INSTALLATION OF ALL MATERIALS.

RESULTING FROM THE PERFORMANCE OF THIS WORK. REPAIRS SHALL MATCH

EXISTING IN TYPE AND QUALITY OF MATERIALS, FINISH, COLOR AND TEXTURE.

CONSULTATION WITH COR AND BUILDING PERSONNEL. PROJECT IS IN A REMOTE

AREA. NO OPENING IS TO REMAIN UNSECURED AFTER NORMAL WORKING HOURS.

ACCESS AROUND WORK AREA EXCEPT FOR SHORT PREANNOUNCED PERIODS AND

SHALL REMOVE CONSTRUCTION DEBRIS DAILY TO APPROPRIATE LOCATIONS.

1. THIS PROJECT INVOLVES THE CONSTRUCTION OF A 82 FOOT BY 62 FOOT METAL

2. PROVIDE AND INSTALL THOSE ITEMS AS DRAWN, DETAILED, AND NOTED ON

3. THE STRUCTURAL STEEL FRAMING FOR THIS BUILDING SHALL BE PRE-ENGINEERED

1. CONTRACTOR SHALL SITE VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO

2. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, LAWS, STANDARDS,

3. CONTRACTOR SHALL REPAIR ALL DAMAGE TO ADJACENT EXISTING CONSTRUCTION

5. CONTRACTOR SHALL ARRANGE PROJECT SCHEDULE AND DAILY WORK HOURS IN

6. CONTRACTOR SHALL PROVIDE FOR THE CONTINUAL VEHICULAR AND PEDESTRIAN

L E G E N D

INDEX OF DRAWINGS

DESCRIPTIONSHT. NO.

AR-1

AR-2

C-1

AC-1

EL-1

EL-2

SCALE: 1" = 20’

S S

6"

P

PP

P

PP

P

P P

M. STOUT

SITE PLAN

STD-128

PL-1

SITE PLAN

FLOOR PLAN AND WALL SECTION

REFLECTED CEILING PLAN

DUCT WORK PLAN AND SCHEDULES

ELECTRICAL LIGHTING PLAN

ELECTRICAL POWER/AUX. PLAN

STANDARD ACCESSIBILITY DETAILS

PLUMBING PLAN

BUILDING 25 FEET TO THE NORTH OF BUILDING 3534 AND INCLUDES ALL

THE EXISTING ADJACENT BUILDING (BLDG. 3534) TO THE MAXIMUM EXTENT POSSIBLE.

SIDING, METAL ROOFING, AND ASSOCIATED COMPONENTS SHALL MATCH THAT OF

REPLACEMENT, BUILDING AND SYSTEMS INSTALLATIONS, AND SITE REPAIR. METAL

DRAWINGS TO INCLUDE CONCRETE FOUNDATIONS AND FLOOR SLAB, STEEL STRUCTURAL

SYSTEM, METAL STUD WALLS, METAL SIDING, METAL ROOFING, WALL, CEILING

FRAMES,ACOUSTIC CEILING TILE AND GRID SYSTEM, VINYL FLOOR TILE, ELECTRICAL

AND ROOF INSULATION, GUTTER AND FASCIA, DOWNSPOUTS, DOORS, WINDOWS,

EQUIPMENT, HVAC SYSTEM, FIXTURES AND EQUIPMENT, AND ALL ASSOCIATED

SYSTEM, FIXTURES, AND EQUIPMENT, PLUMBING SYSTEM, FIXTURES, AND

BY A COMPANY SPECIALIZING IN THE ENGINEERING OF STEEL BUILDING AND

THEIR RELATED COMPONENTS. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR

APPROVAL STAMPED AND SIGNED BY A STRUCTURAL ENGINEER IN THE EMPLOY OF

AND RELATED COMPONENTS.

SAID COMPANY FOR THE DESIGN AND FABRICATION OF THIS STRUCTURAL SYSTEM

SHALL BE ABS PIPE AND FITTINGS, SCHEDULE 40 DWV (ASTM D2661).

BUILDING ENVELOPE IN ABOVE GROUND APPLICATIONS. DRAINAGE PIPING

B88). PVC (AWWA) C-900 MECHANICAL JOINT MAY BE USED INSIDE OF

A21.5) OR COPPER PIPE OR WATER TUBE TYPE K OR L (ASTM B42, ASTM

GALVANIZED STEEL PIPE, CEMENT LINED (ASTM A377, ANSI/AWWA C151/

PIPE MATERIALS FOR UNDERGROUND/UNDERSLAB POTABLE WATER SHALL BE7.

DISTURBED BY THIS WORK.

CONTRACTOR SHALL SMOOTH, FERTILIZE, MULCH, AND SEED ALL AREAS4.

EXISTING

BLDG. 3534

FF ELEV. 651.5

PP

P

P

P

W

W

3"W

S

’-0

M

IN

. T

Y P.

REMOVE O TAP

#2 ACSR 1O

ENDWALLS, TYP.

WITH SLOPED

CONCRETE PIPE

NEW 18" DIAM.

#2 ACSR 3O

DEMO PAVEMENT

SAWCUT ASPHALT,

ROAD

CONC. PIPE UNDER

SEAL AND ABANDON

UNDER NEW BLDG.

DEMO CONC PIPE

WATER PIPE

DEMO AND RELOCATE

SUPPLY

2" WATER

DEMO PAVEMENT

PP

M I N

T Y

P

NEW 3’ WATER LINE

PP

3 O SPAN

REMOVE EXIST.

CATCH BASIN

NEW 24"x24"ENDWALLS, TYP.

PIPE WITH SLOPED

NEW 12" DIAM. CONCRETE

FENCE AND GATE

DEMO EXISTING

TO EXISTING FENCE

HEIGHT AND CONSTRUCTION

ACESS GATES, MATCH FENCE

ELECTRICALLY CONTROLLED

NEW SECURITY FENCE WITH

B L

D G

NEW SIDEWALK

NEW 3" WATER LINE

EXIST. WATER LINE

CB

EXIST. CONC. PIPE

CB

25’-0"

TO EXISTING

ALIGN NEW BLDG.

FF ELEV. 652.5

NEW BLDG. 3545

SCALE: 1" = 10’

ENLARGED SITE PLAN

NEW CONC. PIPE

ASPHALTIC PAVEMENT

SIDEWALK

NEW CONC.

6’-0"

TYP.

BANK TO REMAIN

EXIST. TRANSFORMER

A

E P

S

N E

I D

E W

A L

K

E X I S

T I

I D

E W

A L

K

NEW SIDEWALK

CATCH BASIN

NEW 24"x24"

NEW SIDEWALK

THIS SHEET

SITE PLAN

SEE ENLARGED

1�"

BUILDING

WATER

POWER LINE

SECURITY FENCE

POWER POLE

VALVE BOX

FIRE HYDRANT

MANHOLE

WW

PP

PPPP

CATCH BASINCB CB

S

FH

MH

SAN. SEWERSS

DEMO POWER LINE

DEMO FENCE & GATE

P

CB

CB

CB

DEMO CONC. PIPE

CONC. PIPE

35453534

C STEAM & CON. LINES

C

C

C

C

C

CB

CB

DEMO CATCH BASIN

EXISTING NEW

UNDERGROUND

CONDUIT

UG C

AR-3

AC-2 STEAM AND CONDENSATE PIPING

1�"

GATE

GATE

UG

U G

U G

C

C

18" MIN. COVER

FOR COMMUNICATION

WITH PULL STRING

(2)-4" C. TO POLE

18" MIN. COVER

UG SERVICE LATERAL

2�" RGS C.

(4)-#4/0, (1)-#4 GND.,

18" MIN. COVER

UG SERVICE LATERAL

2�" RGS C.

(4)-#4/0, 1()- #4 GND.,

C S 1"

1"

S C

18" MIN. COVER

(2) 4" C TO POLE

C S

S

C

220TQF/TN-41712

P

C

SS

C

REMAIN

BANK TO

TRANSFORMER

EXISTING

DOOR SCHEDULE AND HARDWARE SCHEDULE

STD-117A WATER & GAS DISTRIBUTION AND SANITARY SEWER

SS

CLEANOUT CO

SS

SS

C.O.

C.O.

S S

C.O. SS

C.O.

NOTE:

BUILDING 3534, USE BM=651.50.

DOUBLE DOORS AT NORTHEAST SIDE OF

IS TO BE TAKEN AT FINISH FLOOR INSIDE

BENCHMARK LOCATION FOR THIS PROJECT

DOUBLE GATE

22’ WIDE

GATE AT WALKWAY

4’ WIDE PEDESTRAIN

MOTORIZED GATE

SWIPE STATION

SECURITY CARD

NOTES:

ALL OTHER CONDUIT SHALL BE RIGID UNLESS OTHERWISE NOTED.

FLEXIBLE FIXTURE WHIPS OR FLEX CONDUIT IS ALLOWED ONLY WITHIN 6 FEET OF LIGHT FIXTURES.

LIGHTING FIXTURE SCHEDULE

MARK

FIXTURE

DESCRIPTION

OR EQUAL

MODEL NO. LAMP

TYPE NO. WATTS VOLTAGE

FIXTURE

NO.

NOTE

2PM4GB43218LS120GEB10

LITHONIA LIGHTING

T4DTT

A1

A2

B1

F

G

H

X

2PM4GB23218LS120GEB10

LITHONIA LIGHTING

AF126DTT8PR120GEB

LITHONIA LIGHTING

2’x4’ FLUORESCENT PARABOLIC TROFFER

2’x4’ FLUORESCENT PARABOLIC TROFFER

RECESSED ARCHITECTURAL DOWNLIGHT

STANDARD INDUTRIAL

T8

T8

4 32

NOTES:

D

C

2, 7

1202’x2’ FLUORESCENT STATIC TROFFER 2 32T8

L 2 32 120

LITHONIA LIGHTING

I

CONTEMPORARY WRAPAROUND DIFFUSER

WALL BRACKET 11857 GEB

LITHONIA LIGHTING

2 12020T12

A1

D

B1 NUMBER. TYPE B1 SHOWN

RECESSED DOWNLIGHT. NUMBER INDICATES CIRCUIT

F

NUMBER IN CENTER INDICATES CIRCUIT NUMBER.

2’x4’ FLUORESCENT PARABOLIC TROFFER. TYPE A1 SHOWN.

SHOWN. NUMBER INDICATES CIRCUIT NUMBER.

STANDARD FLUORESCENT LIGHT. TYPE D

C

NUMBER IN CENTER INDICATES CIRCUIT NUMBER.

2’x2’ FLUORESCENT STATIC TROFFER. TYPE C SHOWN.

T

LEGEND

3a

WALL BRACKET, TYPE "I" SHOWN

CONTEMPORARY WRAP AROUND DIFFUSER

TOGGLE SWITCH, 20A, 120/277V, SPECIFICATION GRADE

SCALE: �"=1’-0"

I

NCC MODEL T1517

TIME DELAY FAN LIGHT SWITCH SIMILAR OR EQUAL TO

1.

2.

3.

4.

M. SMITH

E C

N

E .D

G N

PW-3545

EL-1

i p p e n t a b l e d g n s p e c s y t i m e

BLDG. 3545

LIGHTING PLAN

M. STOUT

220TQF/TN-41712

TECH ESCORT TRAINING

FACILITY

AS SHOWN

FEB. 2002

1.

2.

3.

4.

5.

6.

7.

$4c$4d $4a$4b

$3c$3d

$3

$ 3

$3a$3b$

$4

A1 A1 A1 A1

A1 A1 A1 A1

A1 A1 A1 A1

A1

A1

A1

A1 A1A1A1A1

A1A1A1A1

A1A1A1A1

A1 A1

A2 A1

A1

A1

A2

A1 A1

A1

A1A1A1A1A1

B1 B1 B1

F

ALL DEVICES SHALL BE IVORY IN COLOR WITH METAL FACEPLATES.

GROUNDING CONDUCTOR IN EACH RACEWAY.

OWN NEUTRAL. NO MORE THAN THREE CIRCUITS IN A CONDUIT ARE ALLOWED. PROVIDE A SEPARATE

NOTED. EXTERIOR CIRCUITS SHALL BE INSTALLED IN RGS CONDUIT. EACH CIRCUIT SHALL HAVE ITS

ALL WIRING SHALL BE COPPER THHN/THWN #12 MINIMUM INSTALLED IN �" C. UNLESS OTHERWISE

ELECTRICAL CODE AS A MINIMUM STANDARD.

ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE LATEST NATIONAL

NOT USED

NOT USED

WS 07 S 1 PE

GE LIGHTING SYSTEMS

2SPG2U31FWA12120GEB10

LITHONIA LIGHTING

HPS 120

T8 2 32

PROVIDE WITH PHOTOCELL

TYPE "F" SHOWN

WALL MOUNTED H.I.D. FIXTURE SUBCRIPT " " INDICATES FIXTURE TO BE SWITHCED

THREE-WAY TOGGLE SWITCH, 20A, 120/277V, SPECIFICATION GRADE

17 17 17 17

17171717

171717

18 18 18 18

18181818

18 18 18 18

191919

19 19

20 20

21212121 a b bb baa a a a a b b

D

DDDD

D D D

DDDD

D dd d d dd cc c c cc

DD

D

DD

D D

D DDD

F F

F F

F

PPA-17, 18

A2

A2A2

A2

A2

A2A2A2A2

PPA-19

A2

A2

C C

PPA-20

A2

B1

D21

D

PPA-21

I

A2

D a

D b

D d

D c

FOR CONT.

SEE POWER PLAN

I

S. KRESAL/R. BEEM

D - INDICATES DIMMABLE BALLAST

MOUNT ABOVE MIRROR

NOT USED

MOUNT AT 7�" TO TOP OF FIXTURE A.F.F.

WALL-MOUNTED ENTRANCE AREA H.I.D.

INDICATES FIXTURE TO BE SWITCHED.

THREE-WAY DIMMER SWITCH, 20A, 120/277V, SUBSCRIPT "a"

3Da

FOUR-WAY SWITCH, 20A, 120/277V

NEUTRAL, GROUNDS NOT SHOWN.

SLASHES INDICATE NO OF PHASE CONDUCTORS, LONG SLASH INDICATED

HOMERUN NO. OF ARROWS INDICATE NO. OF CIRCUITS, NO.OF SMALL

I

�" C

�" C�" C

�" C

�" C

�" C

�" C

�" C

�" C�" C �" C

LIGHTING PLAN

ELECTRICAL

T

T

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

M. SMITH

E C

N

E .D

G N

PW-3545

EL-2

i p p e n t a b l e d g n s p e c s y t i m e

BLDG. 3545

POWER PLAN

PHASE LOAD, V-A

0 A 0 B 0 C V-A

LOAD

V-A

LOAD

LOAD SERVED LOAD SERVED

SIZE

WIRE

POLES

NO.

AMPS

TRIP

NO.

CKT.

PANELBOARD PPA BOTTOM FEED

TOTAL

SIZE

WIRE

POLES

NO.

AMPS

TRIP

NO.

CKT.

120/208 VOLTS 3 PHASE 4 WIRE 225 AMP MAINS

1 2

20 1 12

12 1 20

11180

SURFACE MOUNTED

AHU- 1

* HACR TYPE CIRCUIT BREAKER

SUPPLIED FROM TRANSFORMER

*37

ESTIMATED DEMAND LOAD KVA

BOLT ON CIRCUIT BREAKER TYPE

22,000 ASYM A.I.C. MIN.

TVSS

CU-1

AHU- 1

AHU- 1

TOTAL CONNECTED LOAD 58.359 KVA

38*

DISCONNECT SWITCH

400/3/225/3R

TVSS

A.F.F. ABOVE FINISHED FLOOR

U.O.N. UNLESS OTHERWISE NOTED

CEILING/WALL MOUNTED JUNCTION BOX

MOTOR CONNECTION, NUMBER INDICATES HP

J J

NEMA ENCLOSURE DISIGNATION

FUSE RATING (NF-NON-FUSIBLE)

NO. POLES

SWITCH RATING

LEGEND

WITH #2 COPPER

OR BUILDING SERVICE ENTRANCE GROUND AS REQUIRED

GROUND ROD - BOND TO BUILDING STRUCTURAL STEEL

ARROWS INDICATE NUMBER OF HOMERUN CIRCUITS

WIRING CONCEALED IN WALLS OR ABOVE CEILING,

NOTES:

ALL DEVICES SHALL BE IVORY IN COLOR WITH METAL FACEPLATES.

OUTLETS, AT 18" A.F.F. TO CENTER OF BOX UNLESS OTHERWISE NOTED.

REQUIRED ROOM FINISH, MOUNT ALL GENERAL PURPOSE RECEPTACLE OUTLETS AND COMMUNICATION

ALL DEVICE OUTLET BOXES SHALL BE A 4" BOX WITH THE APPROPRIATE PLASTER RING FOR THE

ELECTRICAL CODE AS A MINIMUM STANDARD.

ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE LATEST NATIONAL

5.

4.

3.

2.

1.

FAULT INTERUPT, MOUNT 18" A.F.F. U.O.N.

COVERPLATE, WP-WEATHERPROOF, GFI-GROUND

120V, 20A DUPLEX RECEPTACLE, IVORY WITH METAL

COVERPLATE

120V, 20A SINGLE RECEPTACLE, IVORY WITH METAL

DEVICE FOR WALL MOUNTED PHONE

BEND TOWARD COMM/DATA ROOM. W - INDICATES SINGLE

AND PULL STRING, STUBBED ABOVE CEILING WITH 90°

4" DEVICE BOX, �" CONDUIT WITH INSULATING BUSHING

COMMUNICATIONS OUTLET AT 18" A.F.F., U.O.N., PROVIDE

EQUAL TO NCC MODEL T1517.

SWITCH IN "TIMED" POSITION. LIGHTS ARE OFF AND FAN IS DELAYED OFF. SWITCH IS SIMILAR OR

AND LIGHT CONTROL SWITCH. WITH SWITCH IN "ON" POSITION - FAN AND LIGHTS ARE ON, WITH

BATHROOM EXHAUST FAN SHALL BE SWITCHED WITH BATHROOM LIGHTS VIA A TIME DELAY FAN

M. STOUT

220TQF/TN-41712

AS SHOWN

FEB. 2002

TECH ESCORT TRAINING

FACILITY

M

30/3/NF/1

AHU-1

M

PPA

GFI

WP

100/3/NF/3R

TVSS

"PPA"

PANEL

J

CONTINUATION

PLAN FOR

SEE LIGHTING

WATER HEATER

INSTANTANEOUS

SITE PLAN

STRING TO POLE. SEE

4" C. EA. WITH PULL

STRING ONLY

1�" C., EA. PULL

/110

SEPARATE GROUNDING CONDUCTOR IN EACH RACEWAY.

ITS OWN NEUTRAL. NO MORE THAN THREE CIRCUITS IN A CONDUIT ARE ALLOWED. PROVIDE A

EXTERIOR CIRCUITS SHALL BE INSTALLED IN RGS CONDUIT. EACH SINGLE PHASE CIRCUIT SHALL HAVE

ALL WIRING SHALL BE COPPER THWN #12 MINIMUM INSTALLED IN �" C UNLESS OTHERWISE NOTED.

GROUND WITH #6 SOLID COPPER.

PROVIDE GROUND BAR �" X 2" X 6" MOUNT AT 12" A.F.F. BOND TO SERVICE ENTRANCE6.

WIRING CONCEALED UNDER FLOOR OR IN GROUND

LOCATION ELECTRICAL ROOM

SERVICE EQUIPMENT RATED

FLOOR RECEPT. CLASS RM. 1

RECEPT. CLASS RM. 1

RECEPT. CLASS RM. 1

1440 FLOOR RECEPT. CLASS RM. 2

1260 RECEPT. MEDIA RM.

RECEPT. CLASS RM. 2

RECEPT. COMM. RISER 1800 1440 RECEPT. BATH ROOM

RECEPT. COMM. RISER 360 RECEPT. VENDING / CORRIDOR

RECEPT. CLASS RM. 1 900 1620 RECEPT. COPY / STORAGE

RECEPT. CADRE ADMIN. / OFFICE12601260RECEPT. CADRE ADMIN.

RECEPT. CADRE ADMIN. / CONF.

LIGHTS CLASS RM. 1

1260 1440 RECEPT. CADRE ADMIN./CONF/OFFICE

LIGHTS. CLASS RM. 2

LIGHTS. BATH RM./STORAGE/ADMIN.LIGHTS CORRIDOR / MEDIA

LIGHTS ADMIN.

11180

11180

CU-1

CU-1

ON GRADE INSTALLATION

POWER /DATA FLOOR BOX SUITABLE FOR

S. KRESAL/R. BEEM

11 11 11 11

2 2 2

3 3 3 3

1 1 1 1

7 9

SEE NOTE 6

PPA-2

PPA-7,9,11

PPA-3,5

PPA-1

PPA-4,6

15 16

12 12

PPA

PPA-14,16

13 13 13

13 15 15

PPA-13,15

CU-1

PPA

GFI,42"

GFI,42"

PPA-8,10,12

/13

/13

CP-1

30/2/15/1

/110

FAN EF-1

EXHAUST

LISTED AND RATED FOR SERVICE ENTRANCE

TRANSEINT VOLTAGE SURGE SURPRESSION UL 1449

IF OTHER UNITS ARE USED SIZE CIRCUITS PER MANUFACTURERS RECOMMENDATIONS.

NOTE: CIRCUITS FOR AHU-1 AND CU-1 BASED ON TRANE MODEL TWE240B3 AND TTA240B3 RESPECTIVELY.

SPARE

SPARE

SPARE

CP-1

1364 1364

24933 22367 25259

SPARE

SPACE

TVSS

TVSS

SPACE

SPACE

SPACE

SPACE

PPA-36

COUNTER

ABOVE

30/2/NF/1

�" C (TYP)

�" C (TYP)

GND., 1�" C

3 #3, 1 #8

GFI,42"

SEE SITE PLAN.

EXISTING TRANSFORMER

2�" RGS C. TO

4 #4/0, 1 #4 GND.,

ELECTRICAL

POWER / AUXILLIARY PLAN

8 WATER HEATER MENS RM.

8240 WATER HEATER WOMENS RM.

W

48"

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

T. SMITH

E C

N

P .D

G N

PW-3545

i p p e n t a b l e d g n s p e c s y t i m e

BLDG. 3545

PLUMBING PLAN, RISERS,

PLUMBING PLAN

M. STOUT

220TQF/TN-41712

TECH ESCORT TRAINING

FACILITY

AS SHOWN

FEB. 2002

LEGEND AND NOTES

INV. ELEV. 644.7

DIST. LINE

TO 3" POTABLE

SYMBOL FIXTURE

CW HW

INSTANTANEOUS ELECTRIC WATER HEATER

SYMBOL VOLTAGE AMP KW TEMPERATURE RISE @ .75 GPM

WH-1 208 35 7.1 64° F.

PIPING

WASTE WATER

PLUMBING SCHEDULE

WATER SUPPLY

P-1H

P-2

P-3H

P-4

F.D.

C.O.

CLOSET (FLUSH VALVE)

HANDICAPPED WATER

HANDICAPPED LAVATORY

(4" TRAP SIZE -MIN)

FLOOR DRAINS

CLEAN OUT NA NA

NANA

NA

NA

NA�"

1"

4"

1�"

1�"

1"

3"

4"

MODEL USED FOR DESIGN RP1 - 4E186 FROM GRAINGER PG. 3326

THIS MODEL USED FOR DESIGN USE THIS MODEL OR APPROVED EQUAL.

H.B. HOSE BIBB (NON-FREEZE)

�" NA NA

PLUMBING SCOPE OF WORK:

1.

OTHER APPURTENANCES TO MAKE THE SYSTEM COMPLETE AND OPERABLE.

CONTRACTOR TO FURNISH AND INSTALL ALL PLUMBING AND PLUMBING FIXTURES AS WELL AS ALL

1.

NOTES:

2.

3.

4.

5.

2. ALL FIXTURES TO BE VITREOUS CHINA WHITE.

1. LAVATORY’S TO HAVE GOOSE-NECKED FAUCETS AND SINGLE LEVER HANDLES FOR WATER CONTROL.

COMMENTS:

2"

H.B.

2"

1"

1"

1"

WATER RISER

NOT TO SCALE

TO MANHOLE

4"

F.D.

F.D.

F.D.

1"

3"

3"

1�"

3"

4"

4"

C.O.

F.D.

F.D.

F.D.

VTR

C.O.

4"

3"

1"

3"

1�"

1�"

2"

1�" 4"

4"

4"

4"

4"

4"

4"

4"

2"

1�"

4"

1�"

1�"

1�" 1�"

1�"

NOT TO SCALE

SANITARY WASTE RISER

H.B.

P-1H P-1

P-1

P-3H

P-3

P-2

P-2WH-1

S.S.

P-4

P-3

P-3

WH-1

S L O P E

P E R

F T

SLOPE �" PER FT.

QTY

P-1 NA1" 4"

(FLUSH VALVE)

WATER CLOSET

URINAL

DRINKING FOUNTAIN

P-3 �"�" 1�"LAVATORY

S.S. �" 3"SERVICE SINK �"

PIPES ACCORDINGLY. DO NOT SLOPE WASTE PIPING MORE THAN �" PER FT.

BRING PLUMBING IN AT 651.6. BUILDING FLOOR ELEVATION IS AT 652.5. ADJUST DISCHARGE

330 FT. TO BUILDING PLUMBING ELEVATION WITH A SLOPE OF �" PER FT. THIS SHOULD

DISCHARGE AT MANHOLE INVERT ELEVATION IS 644.7, WITH A APPROXIMATE DISTANCE OF

ALL FLOOR DRAINS SHALL HAVE A MINIMUM OF 4" TRAP SEAL.

PIPING SHALL BE ABS

MAY BE USED INSIDE OF BUILDING ENVELOPE IN ABOVE GROUND APPLICATIONS. DRAINAGE

WATER TUBE TYPE K OR L (ASTM B42, ASTM B88) PVE(AWWA) C-900 MECHANICAL JOINT

STEEL PIPE, CEMENT LINED (ASTM A377, ANSI/AWWA C151/a21.5) OR COPPER PIPE OR

PIPE MATERIALS FOR UNDERGROUND/UNDERSLAB POTABLE WATER SHALL BE GALVANIZED

GROUND PIPING SHALL BE SUPPORTED.

PIPE SUPPORTS SHALL CONFORM TO MSS SP-58, MSS SP-69 AND MSS SP-89. ALL ABOVE

AND VERIFY FIELD CONDITIONS BEFORE BEGINNING INSTALLATION.

DO NOT SCALE DRAWINGS FOR DIMENSIONS, CONTRACTOR TO OBTAIN ALL NECESSARY DATA

PLUMBING CODE LATEST EDITION.

EQUIPMENT AND ACCESSORY ITEMS. PIPING SHALL CONFORM TO THE NATIONAL STANDARD

FOLLOW MANUFACTURES RECOMMENDED PROCEDURES FOR ASSEMBLING AND INSTALLING ALL

6.

NOT TO SCALE

FLOOR SLAB FLOOR DRAIN

WASTE PIPE

P-TRAP

PRIMER CONNCETION

SLEEVE WITH �"

.D

PL-1

TYPICAL TRAP DETAIL

PREVENTER

BACKFLOW

DOUBLE CHECK

FOOT TOWARD DRAIN

SLOPE FLOOR �" PER

PREVENTER

BACKFLOW

DOUBLE CHECK

SCALE

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

WATER DISTRIBUTION,

GAS DISTRIBUTION

AND SANITARY SEWERS

N.T.S.

TYPICAL THRUST BLOCK LOCATIONS

FOR HORIZONTAL CHANGES IN DIRECTION

UNION

UNION

UNION

UNION

CURB STOP WITH ADJUSTABLE

G.I. SERVICE BOX FOR 1• "

GATE VALVE & BOX FOR

2"

CURB STOP WITH ADJUSTABLE

ADJUSTABLE C.I. SERVICE

BOX FOR 1‚ & 1•" "

GATE VALVE & BOX FOR 2"

CURB STOP WITH

ADJUSTABLE C.I.

SERVICE BOX

CURB STOP WITH

ADJUSTABLE C.I.

SERVICE BOX

COUPLING

COUPLING

COUPLING

CORP. STOP

AND MALE

NIPPLE

CORP. STOP

AND MALE

NIPPLE

CORP. STOP

AND MALE

NIPPLE

CORP. STOP

AND MALE

NIPPLE

N.T.S.

SERVICE CONNECTION DETAILS FOR

CAST IRON & CEMENT ASBESTOS PIPE

NOTE:

TAPS INTO CEMENT ASBESTOS PIPE SHALL BE

STAGGERED AS RECOMMENDED BY THE PIPE MANUFACTURER

2" 1"

1• ƒ

FOR 1• & 2" DIA.

1• ƒ

1‚

2"" 1‚

1"

FOR 1 1/4, 1• & 2" DIA." "

1• ƒ

1‚

1"

1"

1‚

FOR 1"; 1• $ 2" DIA."

COPPER GOOSENECK

WITH WIPED OR

FLANGED JOINT

COPPER GOOSENECK

WITH WIPED OR

FLANGED JOINT

COPPER GOOSENECK

WITH WIPED OR

FLANGED JOINT

COPPER GOOSENECK

WITH WIPED OR

FLANGED JOINT

WATER

PLAN

VALVE BOX DETAIL

N.T.S.

SECTION

3/8" DIA. BARS @

8" O.C.E.W.

CONCRETE PAD 3'-0" IN

DIA X 8" THICK OR 3'-0"

SQ. X 8" THICK WHEN VALVE

PAVED AREAS.

N.T.S.

TYPICAL FIRE

HYDRANT SETTING

BLOCK FIRE

HYDRANT WITH

12" X 12" X12"

ROCK OR CONC.

BLOCK

UNDISTERBED EARTH 15" X 15" X 6" CONCRETE BLOCK

7 CU.FT. OF CRUSED ROCK.

GROUND

M I N

Z

E D

U

R B

V

E A

6' MIN. - 7' MAX.

V A

R I A

B L

E

M I N

DIMENSIONS Z SHALL BE 30" MAX.

WHEN FIRE HYDRANT IS LOCATED

NEAR AIRFIELD PAVEMENTS AND

48" MAX. WHEN LOCATED NEAR

ROADS.

V A

R I A

B L

E

N.T.S.

TYPICAL VALVE SETTING

GROUND

ADJUSTIBLE

VALVE BOX

N.T.S.

SERVICE BOX SETTING

V A

R I A

B L

E

GROUND

CURB STOP

EXTENSION SERVICE BOX

N.T.S.

GATE VALVE

STANDARD TEE

3" PIPE & LARGER

2" GATE VALVE

TAPPERED TEE

UNION

UNION

N.T.S.

TYPICAL 2" RIGID CONNECTION

N.T.S.

TYPICAL CONNECTIONS FOR GAS

SERVICE LINE TO MAIN

SECTION

SERVICE COCK

SERVICE TEE

STREET ELL

GAS MAIN

PLAN

TYPICAL CONNECTION FOR

STANDARD CONNECTION DROP CONNECTION

SIDE ELEV.

FRONT ELEV.

SECTION "EE"

TYPICAL SECTION

TYPICAL LADDER DETAIL

STANDARD CONNECTION DROP CONNECTION

TYPICAL SECTION

SEWER CLEANOUT

STANDARD MANHOLE-OVER 12 FT.DEEP

FRAMES AND COVERS

PLAN AND COVER

SECTION "D-D"

PLAN OF FRAME

SECTION "C-C"

SECTION "Y-Y"

PLAN

PLAN

SECTION

FRAME FOR STANDARD M.H.

CLEANOUT

PLUG

V A

R I E

S

1'-6" X 1'-6" X 6"

CONCRETE COLLAR

(CAST IN PLACE)

GRADE

FLOW

SECTION "B-B"

PLAN

SECTION "A-A"

PLAN

N.T.S.

N.T.S.

N.T.S.

N.T.S.

N.T.S.

N.T.S.

N.T.S.

CONCRETE

FLOOR

CONCRETE ENCASEMENT

3 FT.OUTSIDE BELL

RINGS

INSTALL FRAME AND COVER

BOTTOM OF MANHOLE TO BE

SAME AS BOTTOM OF

MANHOLE 6' TO 12' DEEP

NOTE:

COMPLETE STEEL RINGS MAY BE EITHER

LAPPED OR WELDED AT ENDS. ALL BARS

SHALL BE HOOKED TO RINGS.

2'-0"

4'-0"

RINGS 2'-4" O

#3 BARS AT 6" O.C.

APPROX. 5"

8"

TAR PAPER RING

4'-0"

(M

I N

2'-0"

SLOPE CONC. FLOOR

FROM SPRING LINE

ABOUT 2"/FT.

45 OR 30 BEND

45 OR 60 WYE BRANCH

MANHOLE 6 FT.-12 FT.DEEP

APPROX. 5"

8"

TAR PAPER RING4'-0"

2'-0"

45 OR 30 BEND

45 OR 60 WYE BRANCH

(M

I N

(M

A X

LADDER

SEE DETAIL

NOTE: ORIENT MANHOLE SO THAT LADDER WILL NOT

TERMINATE DIRECTLY OVER PIPE.

SEE LADDER DETAIL

2'-2"

2'-0"

2'-3"

3'-3"

MACHINED

ƒ

3‚" ƒ" ƒ

NOTE: SEE SPECIFICATIONS FOR MATERIALS

OF CONSTRUCTION

N.T.S.

2'-1ƒ"

8" ƒ"

" 1

2'-•"

FACE OF WALL

STEEL SIDE RAILS

WELD TO SIDE RAILS

STEEL BRACKET

ƒ" O STEEL RUNGS

2"

2•"6•"

2•"2•"

(MIN.)

ƒ" O STEEL RUNGS

CONC. OR MASONRY WALL DETAIL NO. 1

DETAIL NO. 1

SLOPE EXCEPT IN

PAVED AREAS

DEPTH OF COVER

3"

2'-0"

RINGS

DEPTH OF COVER

NOTE:

RE CONCRETE COVERS AND FRAMES.

ƒ" CLEAR

2'-4 •"

2'-4 •"

USE •" O STEEL IN FRAMES FOR 4" COVER

BOTTOM ONLY

RINGS TOP AND BOTTOM

1 •"

•" LIFT BAR

•" LIFT BAR

…" RINGS

‚" O RING

6"

2'-4"

2'-4"

2'-0"

4'-0"

RING 2'-4" DIAM.

STEEL HINGES MAY BE EITHER HOOKED LAPPED

OR WELDED AT ENDS.

ALL BARS SHALL BE HOOKED TO RINGS.

USE …" O STEEL IN FRAMES FOR 3" COVER

6"5

TOP AND

BOTTOM

SECTIONS "X-X"

1 •"

RINGS

REMOVABLE COVER SHALLOW MANHOLE FRAME

GENERAL NOTES:

CONCRETE COVERS AS SHOWN SHALL BE USED UNLESS OTHERWISE INDICATED.

WHERE MANHOLES ARE SUBJECT TO TRAFFICLOADS, CAST IRON OR 4 - INCH REINFORCED

WHEREVER MANHOLES ARE NOT SUBJECT TO TRAFFIC LOADS, THE COVERS MAY BE

3 - INCH REINFORCE CONCRETE AS SHOWN OR CAST IRON WITHOUT THE RIBS, UNLESS

OTHERWISE INDICATED.

COVER FRAMES SHALL BE SECURELY INSTALLED IN A BED OF CEMENT MORTAR.

1 .

2.

3.

CONCRETE COVERS AND COVER FRAMES

N.T.S.

Y

Y

X

X

LESS THAN 6 FT. DEEP

SHALLOW MANHOLE

USED CLASS A, 3750 PSI. CONCRETE .

SLOPE CONC. FLOOR

FROM SPRING LINE

ABOUT 2"/FT.

…" O RODS ABOUT 4" C.C. TOP AND BOTTOM FOR

USE WHERE SUBJECT TO WHEEL LOADS UP TO 16000

LBS. + 25% IMPACT.

‚" O RODS ABOUT 4" C.C. FOR USE

WHERE TOTAL LOAD WILL NOT EXCEED

6000 LBS.

2•" X …" STEEL RAILS PUNCHED

FOR ƒ" DIA STEEL RUNGS. WELD

RUNGS TO SIDE RAILS.

2•" X …" STEEL BRACKET ATTACHED

TO WALL WITH •" O STEEL INSERTS AND

WELDED TO SIDE RAILS.

E. KRESAL

AS SHOWN

4" MAIN

45 OR 60

4" X 4" WYE

45 OR 60

4" BEND

PW-3545

S

BLDG. 3545

STD-117AFEB 2002

P W

S T

D

A .D

DATE

STRUCTURALMECHANICALELECTRICALCIVILARCHITECTURALMASTER PLANNING

REV BY REQUEST NUMBER DATE SAFETY

USING

SERVICE

CHECKER PROJ ENG CHIEF ENG

REDSTONE ARSENAL SUPPORT ACTIVITY

REDSTONE ARSENAL

REDSTONE ARSENAL,ALABAMA

DRAWN:

FIRE

MARSHAL:

FIRE

MARSHAL

DESIGNED:

CHECKED:

PROJ. ENG.:

SAFETY

DIRECTOR:

REQUEST

NUMBER:

CHIEF ENGINEER

DRAWING NUMBER

SHEET

NUMBER

A. COLE

E C

N

PW-3545

STD-128

220TQF/TN-41712

AS SHOWN

S T

D .D

G N

1'-0

3'-8"

5"

1'-

BLUE IN COLOR

RESERVED

PARKING

BACKGROUND FOR SIGN TO BE WHITE ( NON-REFLECTIVE) WITH BLUE (NON-REFLECTIVE) LETTERS.

CL

SIGN & POST

RESTROOM

1.

2.

VAN

ACCESSIBLE

1'-0"

1•" RADIUS

…" THICK BORDER (GREEN)

•" RADIUS

3" 3"

4„" 4„"

4‡" 5"

12"

EXTERIOR SIGNAGE:

WOMEN'S RESTROOM SIGN

SCALE: 3"=1'-0"

WOMEN'S RESTROOM SIGN

SCALE: 3"=1'-0"

SCALE: 3"=1'-0"

UNISEX RESTROOM SIGN

RESTROOM

SCALE: 3"=1'-0"

UNISEX RESTROOM SIGN

SCALE: 3"=1'-0"

MEN

SCALE: 3"=1'-0"

MEN

INTERIOR SIGNAGE:

INSTALL RESTROOM SIGNS WITH CENTERLINE 5'-0" AFF.

INTERIOR SIGNS SHALL BE LAMINATED ACRYLIC PLASTIC WITHOUT FRAME.

1.

2.

3.

B

C

E

F

G

8"

BLUE BACKGROUND

BRAILLE

PICTOGRAM AND

WHITE LETTERS,

BLUE BACKGROUND

BRAILLE

PICTOGRAM AND

WHITE LETTERS,

8"

WOMENWOMEN

8"

BLUE BACKGROUND

BRAILLE

PICTOGRAM AND

WHITE LETTERS,

BLUE BACKGROUND

BRAILLE

PICTOGRAM AND

WHITE LETTERS,

8"

MEN'S RESTROOM SIGNMEN'S RESTROOM SIGN

8"

BLUE BACKGROUND

BRAILLE

PICTOGRAM AND

WHITE LETTERS,

8"

BLUE BACKGROUND

BRAILLE

PICTOGRAM AND

WHITE LETTERS,

TOILET ACCESSORIES LEGEND AND TYPICAL DIMENSIONS

NO. DESCRIPTION MOUNTING HEIGHT REMARKS

TOILET PAPER HOLDER 1'-7" A.F.F. TO CENTERLINE SURFACE MOUNTED

SHOWER GRAB BAR (18"x32") 3'-0" A.F.F. TO CENTERLINE

SANITARY NAPKIN DISPENSER

SANITARY NAPKIN DISPOSAL

SHOWER ROD W/CURTAIN

42" GRAB BAR

36" GRAB BAR

GLASS MIRROR

GLASS MIRROR

GLASS MIRROR, HANDICAPPED

TOILET SEAT COVER DISPENSER

SHOWER SEAT, HANDICAPPED

ROBE HOOK

SOAP HOLDER

MOP/BROOM HOLDER

PAPER TOWEL DISPENSER

WASTE RECEPTACLE

TOWEL DIPENSER/WASTE RECEPTACLE COMBO

SHELF

URINAL PARTITION

WATER CLOSET PARTITION

WATER CLOSET, WALL-MOUNTED, HANDICAPPED

WATER CLOSET, WALL-MOUNTED

WATER CLOSET, FLOOR-MOUNTED, HANDICAPPED

WATER CLOSET, FLOOR-MOUNTED

WATER CLOSET, TANK TYPE, HANDICAPPED

WATER CLOSET, TANK TYPE

URINAL, HANDICAPPED

URINAL

LAVATORY, HANDICAPPED

LAVATORY

COUNTERTOP - APRON TO MEET ADA

4'-0" A.F.F. TO COIN SLOT

2'-4" A.F.F. TO TOP

3'-4" A.F.F. TO SPOUT

6'-8" A.F.F. TO CENTERLINE

3'-0" A.F.F.