Electrical_Addendum_2-18Apr2016.pdf

PDF 3 MB Posted

Attached to
Building 1467 Renovations Federal contract opportunity
Solicitation number
W9124D-16-B-0001
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Knox

About this file

Electrical Addendum No. 2 Drawings E120C E120D and E306

View the file

Other files for this federal contract opportunity

Other files attached to Building 1467 Renovations, newest first.
File Type Posted
Addendum_No3-22Apr2016.pdf PDF
Responses_to_Requests_for_Information _W9124D-16-B-0001 _22Apr2016.pdf PDF
AD111_-_FIRST_FLOOR_DEMOLITION_PLAN_A-ADDN3.pdf PDF
Addendum_No2-033543_Polished_Concrete_Finishing.pdf PDF
Mechanical_Addendum_2-18Apr2016.pdf PDF
PD110B-ADDN3.pdf PDF
W9124D-16-B-0001_Amendment_0003_Conformed_Copy.pdf PDF
CS100-ADDENDUM3.pdf PDF
W9124D-16-B-0001 _Pre-Bid_Site_Visit_Attendees.pdf PDF
7 ELEC-Electrical-ALLwithADDN1.zip ZIP file
3 ARCH-Architectural-ALLwithADDN1.zip ZIP file
1 GEN-CIVIL- Combined.zip ZIP file
2 STRC-Structural.zip ZIP file
8 TELE-Telecomm-ALLwithADDN1.zip ZIP file
4 FIRE-LS- Fire Protection-ALLwithADDN1.zip ZIP file
7 ELECwAmnd 2.zip ZIP file
9 INTwAmnd 2.zip ZIP file
2 STRCwAmnd 2.zip ZIP file
4 FIREwAmnd 2.zip ZIP file
5 MECHwAmnd 2.zip ZIP file
8-TELEwAmnd 2.zip ZIP file
5a MECHwAmnd 2.zip ZIP file
1_GEN-CIVwAmnd_2_(2).zip ZIP file
Volume_2-ALLwith_Amnd_2.pdf PDF
Volume_1-ALLwith_Amnd_2.pdf PDF
9_INT.zip ZIP file
9a_INT.zip ZIP file
8_TELE.zip ZIP file
9b_INT.zip ZIP file
6_PLUM.zip ZIP file
5a_MECH.zip ZIP file
5_MECH.zip ZIP file
4_FIRE.zip ZIP file
1_GEN-CIVIL.zip ZIP file
2_STRC.zip ZIP file
3_ARCH.zip ZIP file
6_PLUM.zip ZIP file
7_ELEC.zip ZIP file
5_MECH.zip ZIP file
4_FIRE.zip ZIP file
3_ARCH.zip ZIP file
9_INT.zip ZIP file
1_GEN-CIVIL.zip ZIP file
Attachment_1b_-_Drawings_Volume_2_31Mar2016.pdf PDF
Attachment_1a_-_Drawings_Volume_1_31Mar2016.pdf PDF
Attachment_4_-_Ft_Knox_DPW_CADD_Deliverables.pdf PDF
Attachment_9_-_Bldg_1467_Site_ _Storage_Plan.pdf PDF
Attachment_6_-_Fort_Knox_Safety_Reg_385-10.pdf PDF
Solicitation_W9124D-16-B-0001_Fort_Knox_Building_1467_Renovation.pdf PDF
SOW_draft_16-Q-5098_Construction_Bldg_1467_22_Mar_16_Redacted.pdf PDF
Show all 50

Building 1467 Renovations has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STAIR C

GC000

CORRIDOR

GC01

EX STOR

GC02

EX STOR

GC03

EX STOR

GC04

EX STOR

GC05

EX STOR

GC06

EX STOR

GC07

EX STOR

GC08

EX STOR

GC09

STOR.

GC10

STOR.

GC11

COMM.

CGC12

EX STOR

GC13

ELEC.

EGC13

EX STOR

GC091

EX STOR

CGC13

T V

M O

N I T

O R

T V

M O

N I T

O R

LGCR

(DBL. SEC.)

LGCR-14

LGCR-15

E201

LGCR-5

LGCR-1

LGCR-2

LGCR-7

HGBM

1. REFER TO E0.01 FOR GENERAL NOTES, SYMBOL LEGEND

AND LIST OF ABBREVIATIONS.

2. REFER TO TELECOM DRAWINGS FOR DATA AND

TELEPHONE OUTLETS.

3. ALL CIRCUIT BREAKERS THAT SERVE MULTI-WIRE BRANCH

CIRCUITS SHALL BE CONNECTED BY HANDLE TIES TO

SATISFY NEC CODE REQUIREMENTS.

4. CONTRACTOR SHALL COMBINE ONE-POLE BRANCH CIRCUIT

FOR A MAXIMUM OF THREE SINGLE-PHASE CONDUCTORS,

THREE NEUTRAL CONDUCTORS, AND AN EQUIPMENT

GROUNDING CONDUCTOR IN A SINGLE CONDUIT TO

MINIMIZE THE NUMBER OF HOMERUNS WHEN APPLICABLE.

PROVIDE 3#10 + 3#10N + 1#10GND IN 3/4"C FOR THREE

SINGLE-PHASE CIRCUITS, AND 2#10 + 2#10N + 1#10GND IN

3/4"C FOR TWO SINGLE-PHASE CIRCUITS.

1. RECONNECT EXISTING RECEPTACLES IN THIS AREA TO

SPARE 20A/1P CIRCUIT BREAKER IN PANEL "LGCR",

CONNECT A MAXIMUM OF 8 DUPLEX RECEPTACLES FOR

EACH 120A/20A CIRCUIT.

2. PROVIDE (2) 2" RGS (POWER AND CONTROLS). PROVIDE

2#10 + #10 GROUND IN ONE OF THE CONDUITS TO PANEL

LGCR. CONNECT TO CIRCUIT #16.

3. PROVIDE 2#10 + #10 GROUND IN 1" RGS TO LGCR-18.

REFER TO SHEET E120D FOR CONTINUATION

ENGINEERING

PROGRAM MANAGEMENT

CONSTRUCTION MANAGEMENT

6700A ROCKLEDGE DRIVE, SUITE 301

BETHESDA, MARYLAND 20817

(T) 301-216-2871 (F) 301-216-9671 www.THEGES.com

SHEET:

DATE:

DESIGNED BY:

JOB NO:

DRAWN BY:

CHECKED BY:

SCALE:

OF

APPROVED BY:

GENERAL SHEET NOTES

SHEET KEYNOTES

KEYPLAN

A

B

C

D

1 2 3 4 5

1 2 3 4 5

P

L U

M

S

T R

E E

T

T

H

F

L O

O R

C I N

C I N

N A

T I

O

H I O

P H

O N

E

SHEET IDENTIFICATION

B U

I L D

I N

G

R E

N O

V A

T I O

N

F T

K

N O

X

K

Y

F O

U O

MA

31MAR16

54581

EF

ZN

Approver

R E

V I S

I O

N S

N O

D

E S

C R

I P

T I O

N D

A T

E

S

S U

E D

F

R

C O

N S

T R

U C

T I O

N

M A

R

As Indicated

ELECTRICAL

GROUND FLOOR

NEW WORK

PLAN 'C'

SCALE:

ELECTRICAL GROUND FLOOR - NEW WORK PLAN 'C'

1/8"=1'-0"

C

A P

R

A

D D

E N

D U

M

A P

R

A

D D

E N

D U

M

E120C

STOR.

GC10

STAIR

GD000

CORRIDOR

GD01

STORAGE

GD02

WOMEN'S

GD03

JAN.

GD04

MEN'S

GD05

VEST

GD06

COPY/PRINT

GD07

OFFICE

GD08

SERVER

GD09

OFFICE

GD10

MULTI-USE

PLANNING

GD11

OFFICE

GD12

CONF.

GD13

CONF.

GD14

OFFICE

GD15

OFFICE

GD16

OFFICE

GD17

PLANNING

GD18

OFFICE

GD19

OFFICE

GD20

TRAINING

GD24

SERVER

GD22

P A

S S

A G

E

G D

RECEPT.

GD25

ELEC.

EGC13

JAN

GD35

SHELL

SHOWERS

GD33

SHELL

SHOWERS

GD31

VEST

GD34

VEST

GD32

PLOTTER

F I L

E

C

A B

F I L

E

C

A B

P R

SHRDR

P R

W O

R K

T

A B

L E

S A

F E

SAFE

UC

SAFE

TV

MONITOR

TV

MONITOR

SAFE

P R

UC

SAFE

S E

R V

E R

T V

M O

N I T

O R

TV

MONITOR

T V

M O

N I T

O R

T V

M O

N I T

O R

TV

TV

LGCSB

(DBL. SEC.)

OHB (E)

LGCR-11

LGCR-12

LGCSB-16

LGCSB-18

LGCSB-19

LGCSB-20

LGCSB-21

LGCSB-22

LGCSB-23

LGCSB-1

LGCSB-3

LGCSB-4

P

LGCCB-5

P

P

P

P

P

LGBSB-07,09,11

LGBSB-13,15,17

LGCSB-8

LGCSB-14

LGCSB-10

LGCSB-16

LGCSB-24

LGCSB-25

LGCSB-26

LGCR-13

LGCR-14

TV

LGCSB-27,29

LGCSB-31,33

LGCSB-35,37

LGCSB-28

LGCSB-30

LGCSB-32

P

LGCSB-43,45

LGCSB-39,41

LGCSB-35,37

LGCSB-34

LGCSB-36

LGCSB-338

LGCR-5

LGCR-1

LGCR-3

LGCR-6

LGCR-2

LGCR-4

(TYP OF 3)

(TYP OF 3)

1. REFER TO E0.01 FOR GENERAL NOTES, SYMBOL LEGEND

AND LIST OF ABBREVIATIONS.

2. REFER TO TELECOM DRAWINGS FOR DATA AND

TELEPHONE OUTLETS.

3. ALL CIRCUIT BREAKERS THAT SERVE MULTI-WIRE BRANCH

CIRCUITS SHALL BE CONNECTED BY HANDLE TIES TO

SATISFY NEC CODE REQUIREMENTS.

4. CONTRACTOR SHALL COMBINE ONE-POLE BRANCH CIRCUIT

FOR A MAXIMUM OF THREE SINGLE-PHASE CONDUCTORS,

THREE NEUTRAL CONDUCTORS, AND AN EQUIPMENT

GROUNDING CONDUCTOR IN A SINGLE CONDUIT TO

MINIMIZE THE NUMBER OF HOMERUNS WHEN APPLICABLE.

PROVIDE 3#10 + 3#10N + 1#10GND IN 3/4"C FOR THREE

SINGLE-PHASE CIRCUITS, AND 2#10 + 2#10N + 1#10GND IN

3/4"C FOR TWO SINGLE-PHASE CIRCUITS.

5. PROVIDE DIELECTRIC BREAK WITHIN 6" OF ENTERING

CONTROLLED ACCESS SPACE ON CONDUIT FEEDING PANEL

LGCSB. REFER TO DETAIL 2 THIS SHEET.

1. PROVIDE 3#10 + 3#10N + 1#10GND + 1#10 IGND IN 3/4"C.

2. PROVIDE 2#12 + 1#12N + 1#12GND IN 3/4"C.

3. PROVIDE A NEMA L6-30R AND A QUAD RACK-MOUNTED

RECEPTACLES PER RACK AS SHOWN . COORDINATE

RECEPTACLES LOCATION AND NEMA CONFIGURATION WITH

GOVERNMENT.

4. GROUND REFRIGERANT PIPE WITHIN 6” OF ENTERING CA

AREA. PROVIDE #4 AWG GROUND TO BUILDING GROUND.

REFER TO SHEET M120D FOR REFRIGERANT PIPE

LOCATION.

5. GROUND SANITARY PIPE WITHIN 6” OF ENTERING CA AREA.

PROVIDE #4 AWG GROUND TO BUILDING GROUND. REFER

TO SHEET P110D FOR SANITARY PIPE LOCATION.

6. PROVIDE 2#10 + #10 GROUND IN 1" RGS TO LGCR-18.

REFER TO CIVIL DRAWINGS SHEET CS100 FOR

CONTINUATION

PHENOLIC COUPLING

14" MAX.

COMPRESSION

CONNECTOR

COMPRESSION

CONNECTOR

PHENOLIC COUPLING

14" MAX.

COMPRESSION

CONNECTOR

COMPRESSION

CONNECTOR

PHENOLIC COUPLING

14" MAX.

METAL

CONDUIT

METAL

CONDUIT

COMPRESSION

CONNECTOR

COMPRESSION

CONNECTOR

ENGINEERING

PROGRAM MANAGEMENT

CONSTRUCTION MANAGEMENT

6700A ROCKLEDGE DRIVE, SUITE 301

BETHESDA, MARYLAND 20817

(T) 301-216-2871 (F) 301-216-9671 www.THEGES.com

SHEET:

DATE:

DESIGNED BY:

JOB NO:

DRAWN BY:

CHECKED BY:

SCALE:

OF

APPROVED BY:

GENERAL SHEET NOTES

SHEET KEYNOTES

KEYPLAN

A

B

C

D

1 2 3 4 5

1 2 3 4 5

P

L U

M

S

T R

E E

T

T

H

F

L O

O R

C I N

C I N

N A

T I

O

H

P H

O N

E

SHEET IDENTIFICATION

B U

I L D

I N

G

R E

N O

V A

T I O

N

F T

K

N O

X

K

Y

F O

U O

MA

31MAR16

54581

EF

ZN

Approver

R E

V I S

I O

N S

N O

D

E S

C R

I P

T I O

N D

A T

E

S

S U

R

C O

N S

T R

U C

T I O

N

M A

R

As Indicated

ELECTRICAL

GROUND FLOOR

NEW WORK

PLAN 'C'

E120D

SCALE:

ELECTRICAL GROUND FLOOR - NEW WORK PLAN 'D'

1/8"=1'-0"

D

SCALE:

PHENOLIC COUPLING DETAIL

NTS

A P

R

A

D D

E N

D U

M

A P

R

A

D D

E N

D U

M

PANELBOARD KEY

LGBR

H3CL

H3BL LGCR

LGBR

SEC-2

SEC-1

ENGINEERING

PROGRAM MANAGEMENT

CONSTRUCTION MANAGEMENT

6700A ROCKLEDGE DRIVE, SUITE 301

BETHESDA, MARYLAND 20817

(T) 301-216-2871 (F) 301-216-9671 www.THEGES.com

SHEET:

DATE:

DESIGNED BY:

JOB NO:

DRAWN BY:

CHECKED BY:

SCALE:

OF

APPROVED BY:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

P

L U

M

S

T R

E E

T

T

H

F

L O

O R

C I N

C I N

N A

T I

O

H

P H

O N

E

SHEET IDENTIFICATION

B U

I L D

I N

G

R E

N O

V A

T I O

N

F T

K

N O

X

K

Y

F O

U O

MA

31MAR16

54581

EF

ZN

Approver

R E

V I S

I O

N S

N O

D

E S

C R

I P

T I O

N D

A T

E

S

S U

R

C O

N S

T R

U C

T I O

N

M A

R

As Indicated

ELECTRICAL

PANEL

SCHEDULES

E306

A P

R

A

D D

E N

D U

M

A P

R

A

D D

E N

D U

M

File details come from the government source that posted it. Updated .