Amendment 6 Revised Drawings(updated 2 Dec 19).pdf
PDF 5 MB Posted
- Attached to
- W9123820B0001 - Tracy ACP Federal contract opportunity
- Solicitation number
- W91238-20-B-0001
About this file
This pre-solicitation notice provides details for an upcoming Invitation for Bid for construction services at the Defense Depot San Joaquin in Tracy, California. The solicitation will upgrade facilities at the main access control point, including a gatehouse, visitor control center, vehicle inspection facility, guard booths, and overwatch buildings. Upgrades include fire suppression and alarm systems, mass notification, HVAC, electrical, communications, building automation, energy monitoring, and utilities. The estimated cost range is $15-25 million. The performance period after notice to proceed is 540 days. The NAICS code is 236220 for construction of institutional buildings. The size standard is $36.5 million. Questions should be directed to the identified contracting specialist. Interested parties must register in SAM and FedBizOpps to access solicitation documents posted exclusively on FedBizOpps. The anticipated solicitation issuance is end of October 2019.
View the file
Other files for this federal contract opportunity
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
STATE
OF
S
NIO A L E
O F E
S I
G
R E E
N
NO.
45847
H C
SE
A
LR
OM SA
SI
VA
D
P R
FL R IO AD
ESI ENCL
CHARLES AMOS DAVIS
LICENSE NO. 45847
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/FP_TRACY_VCC.rvt
11/20/2019 10:13:06 AM
261169
FP-100
BLDG 128
L
IF
E S
A F
E T
Y N
O T
E S
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A L
IF
O
R N
IA
-2
J
U N
E
W -1
-D
-0
100% DRAWINGS - 14 JUNE 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
V
IS
T O
R C
O N
T R
O L
C E
N T
E R
LIFE SAFETY ANALYSIS
OCCUPANCY CLASSIFICATION:
THE INSPECTION FACILITY BUILDING IS CLASSSIFIED AS A BUSINESS OCCUPANCY PER NFPA 101 AND
BUSINESS (B) PER THE IBC.
APPLICABLE CODES
· UFC 1-200-01 DOD BUILDING CODE (GENERAL BUILDING REQUIREMENTS), 20 JUNE 2016
WITH CHANGE 1, 01 FEB. 2018
· UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016 WITH
CHANGE 2, 25 MARCH 2018
· NFPA 101 LIFE SAFETY CODE, 2018
· IBC INTERNATIONAL BUILDING CODE, 2015
OCCUPANCY
USE
AREA
(ft²)
LOAD FACTOR
(ft²/PERSON)
NUMBER OF
OCCUPANTS
ASSEMBLY -
CONCENTRATED
226 7 N 32
ASSEMBLY - LESS
CONCENTRATED
304 15 N 20
BUSINESS 1629 150 G 11
SUPPORT SPACES 361 500 G 4
TOTAL 2520 67
EXIT CAPACITIES
EXIT
REQUIRED
(PERSONS)
PROVIDED
(PERSONS)
REQUIRED
(IN)
PROVIDED
(IN)
E:109 1 170 34 34
E:110 1 170 34 34
E:111 1 170 34 34
E:112 23 210 34 42
TOTAL 67 1060 170 212
COMMON PATH OF
TRAVEL (FT)
TRAVEL DISTANCE
LIMIT (FT)
DEAD-END
LIMIT
TYPE OF
OCCUPANCY
ALLOWED ACTUAL ALLOWED ACTUAL ALLOWED ACTUAL
BUSINESS 100 32 300 66 50 NONE
INTERNATIONAL BUILDING CODE ANALYSIS
CONSTRUCTION TYPE:
a. TYPE V-S
b. NON-RATED
c. UNPROTECTED (STRUCTURE)
d. FULLY SPRINKLERED
AREA LIMITATIONS (IBC):
FOR BUSINESS (B) OCCUPANCIES, TABLE 506.2 ALLOWS AN AREA OF 36,000 SQ. FT. FOR SINGLE STORY SPRINKLER PROTECTED BUILDINGS. A FRONTAGE INCREASE IS NOT REQUIRED. THE ACTUAL FLOOR AREA IS 2724 SQ.
FT. THE BUILDING COMPLIES WITH THE AREA REQUIRMENTS OF THE IBC.
HEIGHT LIMITATIONS:
PER TABLE 504.4 THE ALLOWABLE HEIGHT OF THIS FULLY SPRINKLER PROTECTED BUILDING IS 75 FEET AND 4 STORIES. THIS IS A SINGLE STORY BUILDING WITH AN ACTUAL HEIGHT OF 20 FEET, WHICH COMPLIES WITH THE IBC.
OCCUPANCY LOAD
OCCUPANCY COUNT PER AREA USE (N = NET, G = GROSS) LOAD FACTORS FROM
TABLE 10-1 IN UFC 3-600-01 AND TABLE 7.3.1.2 NFPA 101.
EGRESS COMPONENTS (ALLOWED/REQUIRED VS. ACTUAL)
MINIMUM CONSTRUCTION REQUIREMENTS:
PARAGRAPH 38.1.6 OF NFPA 101 DOES NOT PROVIDE A MINIMUM CONSTRUCTION TYPE FOR BUSINESS OCCUPANCIES.
FIRE SUPPRESSION:
THIS BUILDING IS REQUIRED TO BE CONSTRUCTED AS A SHELTER-IN-PLACE FACILITY. THEREFORE IT IS TO BE PROVIDED WITH A WET-PIPE SPRINKLER SYSTEM PER UFC 04-23-010 SAFE HAVENS. AN AUTOMATIC SPRINKLER
SYSTEM IS PROVIDED.
FIRE ALARM:
A LIMITED APPLICATION FIRE ALARM SYSTEM IS REQUIRED AND PROVIDED FOR THIS BUILDING.
INTERIOR FINISHES:
PARAGRAPH 38.3.3 REQUIRES CLASS A, B OR C INTERIOR WALL AND CEILING FINISHES. PARAGRAPH 38.3.3.2 REQUIRES CLASS A OR B IN EXITS AND EXIT ACCESS CORRIDORS. THE INTERIOR WALLS AND CEILING FINISHES WILL BE CLASS A, B, OR C AND THE EXITS AND EXIT ACCESS CORRIDORS WILL BE CLASS A OR B.
ILLUMINATION:
ILLUMINATION OF MEANS OF EGRESS IS REQUIRED AND PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS.
EMERGENCY LIGHTING:
EMERGENCY LIGHTING IS PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS.
REMOTENESS:
THE MECH, ELEC, AND COMM EACH HAVE AN INDIVIDUAL EXIT, ALL OTHER ROOMS IN THE BUILDINGS HAVE ONE SHARED EXIT. THE LONGEST TRAVEL DISTANCE ONE MUST TRAVEL TO AN EXIT IN THIS BUILDING IS 67'.
OCCUPANCY SEPARATION (IBC):
THIS BUILDING IS A BUSINESS OCCUPANCY WITH ACCESSORY SPACES AS ALLOWED BY 508.2.
BUILDING SEPARATION (IBC):
PER TABLE 602 TYPE II-B BUILDINGS WITH BUSINESS OCCUPANCY AND NO EXTERIOR WALL RATING MAY BE AS CLOSE AS 10 FEET APART. PER TABLE 705.8 FOR BUILDINGS OF TYPE II-B CONSTRUCTION 20 FEET OR MORE APART, THERE IS NO LIMIT TO THE OPENING IN WALLS. THIS BUILDING IS MORE THAN 20 FEET FROM ANY ADJACENT
BUILDING AND COMPLIES WITH THE IBC FOR SEPARATION.
CLASSIFICATION OF OCCUPANCY:
PER PARAGRAPH 304.1 OF THE IBC THIS BUILDING WILL CLASSIFY B (BUSINESS).
NFPA 101 REQUIREMENTS
EGRESS:
LIFE SAFETY PLANS HAVE BEEN DEVELOPED TO SHOW COMPLIANCE WITH THE EGRESS REQUIREMENTS
OF NFPA 101
FIRE/SMOKE RESISTANCE:
THERE IS NO FIRE/SMOKE RESISTANCE REQUIRED FOR THIS BUILDING AND NONE WILL BE
INCLUDED.
NON-BEARING PARTITION FIRE RESISTANCE:
THE BUILDING HAS A SPRINKLER SYSTEM AND NO FIRE SEPARATIONS ARE REQUIRED.
CLASSIFICATION OF OCCUPANCY:
PER NFPA 101 THIS WILL BE A BUSINESS OCCUPANCY PER PARAGRAPH 6.1.11.
CLASSIFICATION OF HAZARD OF CONTENTS:
THIS BUILDING WILL MEET THE DEFINITION OF ORDINARY HAZARD OF CONTENTS AS PROVIDED IN
PARAGRAPH 6.2.2.3.
E:101 41 340 34 68
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/1 /1
E:
N
STATE
OF
S N
IO A L E
O F E
S I
G
R E E
N
NO.
45847
H C
SE
A
L R
OM SA
SI
V
A D
P R
FL R IO AD
ESI ENCL
CHARLES AMOS DAVIS
LICENSE NO. 45847
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/FP_TRACY_INSPECTION_FACILITY.rvt
11/20/2019 10:18:07 AM
261223
FP-101
BLDG 131
L
IF
E S
A F
E T
Y P
L A
N
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A L
IF
O
R N
IA
-2
J
U N
E
W -1
-D
-0
100% DRAWINGS - 14 JUNE 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
I N
S P
E C
T
IO
N B
U
IL
D
IN
G
7' -6
WAIT
OFFICE
BREAK
TOILET
ELECT
COMM
CPT15 FT.
LIFE SAFETY ANALYSIS
OCCUPANCY CLASSIFICATION
THE INSPECTION FACILITY BUILDING IS CLASSIFIED AS A BUSINESS OCCUPANCY PER NFPA 101 AND
BUSINESS (B) PER THE IBC.
APPLICABLE CODES
· UFC 1-200-01 DOD BUILDING CODE (GENERAL BUILDING REQUIREMENTS), 20 JUNE 2016 WITH
CHANGE 2, 01 NOV. 2018
· UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016 WITH
CHANGE 2, 25 MARCH 2018
· NFPA 101 LIFE SAFETY CODE, 2018
· IBC INTERNATIONAL BUILDING CODE, 2018
ROOM NAME
OCCUPANCY
USE
AREA
(ft²)
LOAD FACTOR
(ft²/PERSON)
NUMBER OF
OCCUPANTS
BREAK
ROOM
ASSEMBLY - LESS
CONCENTRATED
N
OFFICE BUSINESS 122 150 1
WAIT
ASSEMBLY - LESS
CONCENTRATED
61 15N 4
TOILET BUSINESS 39 150 1
ELECTRICAL MECH/ELEC 61 500 1
COMM MECH/ELEC 106 500 1
TOTAL 496 15
EXIT CAPACITIES
EXIT
REQUIRED
(PERSONS)
PROVIDED
(PERSONS)
REQUIRED
(IN)
PROVIDED
(IN)
E:1 4 170 34 34
E:2 1 170 34 34
E:3 1 170 34 34
E:4 1 170 34 34
E:5 1 170 34 34
E:6 7 170 34 34
TOTAL 15 1020 204 204
INTERNATIONAL BUILDING CODE ANALYSIS
CONSTRUCTION TYPE:
a. TYPE V-NS
b. NON-RATED
c. UNPROTECTED (STRUCTURE)
d. NO SPRINKLERS
AREA LIMITATIONS (IBC):
FOR BUSINESS (B) OCCUPANCIES, TABLE 506.2 ALLOWS AN AREA OF 9,000 SQ. FT.
FOR SINGLE STORY NON-SPRINKLER PROTECTED BUILDINGS. A FRONTAGE INCREASE IS
NOT REQUIRED. THE ACTUAL FLOOR AREA IS 503 SQ. FT. THE BUILDING COMPLIES WITH
THE AREA REQUIRMENTS OF THE UFC.
HEIGHT LIMITATIONS:
PER TABLE 504.4 THE ALLOWABLE HEIGHT OF THIS NON-SPRINKLER PROTECTED
BUILDING IS 55 FEET AND 3 STORIES. THIS IS A SINGLE STORY BUILDING WITH AN
ACTUAL HEIGHT OF 14 FEET, WHICH COMPLIES WITH THE IBC.
OCCUPANCY SEPARATION (IBC):
THIS BUILDING IS A BUSINESS OCCUPANCY WITH ACCESSORY SPACES AS ALLOWED BY
508.2.
CLASSIFICATION OF OCCUPANCY:
PER PARAGRAPH 304.1 OF THE IBC THIS BUILDING WILL CLASSIFY B (BUSINESS).
BUILDING SEPARATION (IBC):
PER TABLE 602 TYPE II-B BUILDINGS WITH BUSINESS OCCUPANCY AND NO EXTERIOR
WALL RATING MAY BE AS CLOSE AS 10 FEET APART. PER TABLE 705.8 FOR BUILDINGS
OF TYPE II-B CONSTRUCTION 20 FEET OR MORE APART, THERE IS NO LIMIT TO THE
OPENING IN WALLS. THIS BUILDING IS MORE THAN 20 FEET FROM ANY ADJACENT
BUILDING AND COMPLIES WITH THE IBC FOR SEPARATION.
REMOTENESS:
ALL ROOMS HAVE A SINGLE EXIT, THEREFORE REMOTENESS DOES NOT APPLY.
OCCUPANCY LOAD
OCCUPANCY COUNT PER AREA USE (N = NET, G = GROSS) LOAD FACTORS FROM TABLE 10-1 IN UFC 1-300-01 AND
TABLE 7.3.1.2 NFPA 101.
NFPA 101 REQUIREMENTS
EGRESS:
LIFE SAFETY PLANS HAVE BEEN DEVELOPED TO SHOW COMPLIANCE WITH THE EGRESS REQUIREMENTS OF NFPA 101.
FIRE/SMOKE RESISTANCE:
THERE IS NO FIRE/SMOKE RESISTANCE REQUIRED FOR THIS BUILDING.
NON-BEARING PARTITION FIRE RESISTANCE:
NO FIRE SEPARATIONS ARE REQUIRED.
FIRE SUPPRESSION:
THIS BUILDING IS NOT REQUIRED TO BE PROVIDED WITH A FIRE SPRINKLER SYSTEM AND NONE WILL BE INCLUDED.
FIRE ALARM:
THIS BUILDING IS NOT REQUIRED TO BE PROVIDED WITH A FIRE ALARM SYSTEM AND NONE WILL BE INCLUDED.
MINIMUM CONSTRUCTION REQUIREMENTS:
PARAGRAPH 38.1.6 OF NFPA 101 DOES NOT PROVIDE A MINIMUM CONSTRUCTION TYPE FOR BUSINESS OCCUPANCIES.
CLASSIFICATION OF HAZARD CONTENTS:
THIS BUILDING WILL MEET THE DEFINITION OF ORDINARY HAZARD OF CONTENTS AS PROVIDED IN PARAGRAPH 6.2.2.3.
CLASSIFICATION OF OCCUPANCY:
PER NFPA 101 THIS WILL BE A BUSINESS OCCUPANCY PER PARAGRAPH 6.1.11.
INTERIOR FINISHES:
PARAGRAPH 38.3.3 REQUIRES CLASS A, B OR C INTERIOR WALL AND CEILING FINISHES. PARAGRAPH 39.3.3.2 REQUIRES
CLASS A OR B IN EXITS AND EXIT ACCESS CORRIDORS. THE INTERIOR WALLS AND CEILING FINISHES WILL BE CLASS A, B, OR C AND THE EXITS AND EXIT ACCESS CORRIDORS WILL BE CLASS A OR B.
ILLUMINATION:
ILLUMINATION OF MEANS OF EGRESS IS REQUIRED AND PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS.
EMERGENCY LIGHTING:
EMERGENCY LIGHTING IS PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS.
COMMON PATH OF
TRAVEL (FT)
TRAVEL DISTANCE
LIMIT (FT)
DEAD-END
LIMIT (FT)
TYPE OF
OCCUPANCY
ALLOWED ACTUAL ALLOWED ACTUAL ALLOWED ACTUAL
BUSINESS 50 15 250 15 50 NONE
EGRESS COMPONENTS (ALLOWED/REQUIRED VS. ACTUAL)
LIFE SAFETY FLOOR PLAN
1/4"=1'-0"
<170> E: 2
<170> E: 3
<170> E:
<170> E:
<170> E:
<170> E:
AL
AL
B B
SP
SP
SP
AL
B
PLAN LEGEND
NUM
CAP
XX
AREA
LOAD FAC
NUM OCCUPANT LOAD CALCULATION NUM IS THE NUMBER OF
OCCUPANTS, AREA IS THE AREA OF THE ROOM IN SQ.FT.
AND LOAD FAC IS THE LOAD FACTOR IN SQ.FT./PERSON
TOTAL NUMBER OF OCCUPANTS GOING THROUGH AN EXIT
EXIT IDENTIFICATION: CAP IS THE CAPACITY OF THE EXIT,
NUM IS THE EXIT NUMBER.
BUSINESS USE (NFPA 101), B (IBC)
ASSEMBLY - LESS CONCENTRATED USE (NFPA 101), A-3
(IBC)
BUILDING SUPPORT SPACE (MECH/COMM/ELEC)
0 2' 4' 8'
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/1
E:
N
STATE
OF
S N
IO A L E
O F E
S I
G
R E E
N
NO.
45847
H C
SE
A
L R
OM SA
SI
V
A D
P R
FL R IO AD
ESI ENCL
CHARLES AMOS DAVIS
LICENSE NO. 45847
W D
A
B
C & C
305 SF
STORAGE
39 SF
TOILET
45 SF
ELEC
40 SF
COMM
61 SF
E:105B <170>
E:105A <170>
E:104 <170>
E:102 <170>
E:101 <170>
E:103 <170>
18 FT TRAVEL DISTANCE
16 FT
COMMON PATH OF
TRAVEL
B
S
B
SP
SP
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/FP_TRACY_GATEHOUSE.rvt
11/20/2019 10:19:11 AM
261247
FP-101
BLDG 133
L
IF
E S
A F
E T
Y P
L A
N
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A
-2
J
U N
E
W -1
-D
100% DRAWINGS - 14 JUNE 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
G A
T E
H O
U S
E
1/4" = 1'-0"
FLOOR PLAN
LIFE SAFETY ANALYSIS
OCCUPANCY CLASSIFICATION
THE GATEHOUSE IS CLASSSIFIED AS A BUSINESS (B) OCCUPANCY PER NFPA 101.
APPLICABLE CODES
UFC 1-200-01 DOD BUILDING CODE (GENERAL BUILDING REQUIREMENTS), 1 NOVEMBER 2018
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016 WITH CHANGE 2, 25 MARCH 2018
NFPA 101 LIFE SAFETY CODE, 2018
IBC INTERNATIONAL BUILDING CODE, 2015
OCCUPANCY COUNT PER AREA USE (N = NET, G = GROSS) LOAD FACTORS FROM NFPA 101.
OCCUPANCY SEPARATION
NOT APPLICABLE
MINIMUM CONSTRUCTION REQUIREMENTS
FOR A SINGLE STORY UNSPRINKLERED BUILDING, ANY TYPE OF CONSTRUCTION IS ALLOWED.
EGRESS COMPONENTS (ALLOWED/REQUIRED VS. ACTUAL)
OCCUPANCY
USE
AREA
(ft²)
LOAD FACTOR
(ft²/PERSON)
NUMBER OF
OCCUPANTS
BUSINESS 350 ACTUAL 3
STORAGE 39 500 1
SUPPORT
SPACES
101 500 2
ALLOWED/
REQUIRED
ACTUAL
COMMON PATH OF TRAVEL (FT) 75 16
TRAVEL DISTANCE (FT) 200 18
DEAD END CORRIDOR (FT) 20 0
MINIMUM CORRIDOR WIDTH (IN) 36 N/A
NUMBER OF EXITS 5 6
PROTECTION
HAZARDS
ALL EXITS ARE DOORS TO THE EXTERIOR, THEREFORE NO PROTECTION FOR EXITS IS REQUIRED. CORRIDORS ARE
NOT REQUIRED TO BE RATED PER NFPA 101 PARAGRAPH 38.3.6 (3). THERE ARE NO RATED CORRIDORS IN THE
BUILDING.
INTERIOR FINISH
INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS A B, OR C IN ALL CORRIDORS. INTERIOR FLOOR FINISH
SHALL BE NOT LESS THAN CLASS II IN ACCORDANCE WITH NFPA 101 12.3.3. INTERIOR WALL FINISHES ARE
PAINTED GYPSUM BOARD OR CERAMIC TILE AND ARE CONSIDERED A CLASS A FINISH. CEILINGS ARE EITHER
EXPOSED, PAINTED GYPSUM BOARD OR ACOUSTICAL CEILING TILE. FLOORS ARE PORCELAIN TILE.
ALL INTERIOR WALL AND CEILING FINISHES ARE CLASS A. ALL FLOOR FINISHES ARE CLASS I.
EXTINGUISHMENT REQUIREMENTS
FIRE EXTINGUISHERS ARE REQUIRED. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS.
CORRIDORS
N/A
SUBDIVISION OF BUILDING SPACES (OTHER THAN OCCUPANCY SEPARATION)
NONE REQUIRED
BUILDING CODE ANALYSIS
THIS BUILDING MEETS THE CRITERIA FOR UNLIMITED AREA BUILDING. THE BUILDING IS APPROXIMATELY 819 SQFT.
ALLOWABLE HEIGHT
THE ALLOWABLE HEIGHT IS 40 FEET. THE TALLEST POINT OF THE 819 IS APPROXIMATELY 9 FT.
ALLOWABLE STORIES
THE MAXIMUM ALLOWABLE STORIES IS 3. THE GATEHOUSE IS ONE STORY.
FIRE RESISTANCE RATING FOR STRUCTURAL ELEMENTS.
NO FIRE RESISTANCE RATING IS REQUIRED FOR TYPE IIB CONSTRUCTION.
EXIT DISCHARGE
ALL EXITS DISCHARGE ONTO A YARD OR PUBLIC WAY AS REQUIRED BY NFPA 101 SECTION 7.7.1
ILLUMINATION
ILLUMINATION OF MEANS OF EGRESS IS REQUIRED AND PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS.
EMERGENCY LIGHTING
EMERGENCY LIGHTING IS PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS.
MARKING OF THE MEANS OF EGRESS
MEANS OF EGRESS MARKING IS REQUIRED AND PROVIDED. SEE ELECTRICAL SHEETS FOR DETAILS
FIRE DETECTION AND ALARM SYSTEMS
FIRE DETECTION AND ALARM SYSTEMS ARE NOT REQUIRED
X
PLAN LEGEND
NUM
CAP
AREA
LOAD FAC
NUM OCCUPANT LOAD CALCULATION NUM IS THE NUMBER OF
OCCUPANTS, AREA IS THE AREA OF THE ROOM IN SQ.FT.
AND LOAD FAC IS THE LOAD FACTOR IN SQ.FT./PERSON
TOTAL NUMBER OF OCCUPANTS GOING THROUGH AN EXIT
EXIT IDENTIFICATION: CAP IS THE CAPACITY OF THE EXIT,
NUM IS THE EXIT NUMBER.
BUSINESS USE (NFPA 101), B (IBC)
BUILDING SUPPORT SPACE (MECH/COMM/ELEC)
STORAGE USE (NFPA 101); STORAGE S-1 (IBC)
B
SP
S
0 2' 4' 8'
INTERNATIONAL BUILDING CODE ANALYSIS
CONSTRUCTION TYPE:
a. TYPE V-NS
b. NON-RATED
c. UNPROTECTED (STRUCTURE)
d. NO SPRINKLERS
AREA LIMITATIONS (IBC):
FOR BUSINESS (B) OCCUPANCIES, TABLE 506.2 ALLOWS AN AREA OF 9,000 SQ. FT.
FOR SINGLE STORY NON-SPRINKLER PROTECTED BUILDINGS. A FRONTAGE INCREASE IS
NOT REQUIRED. THE ACTUAL FLOOR AREA IS 503 SQ. FT. THE BUILDING COMPLIES WITH
THE AREA REQUIRMENTS OF THE UFC.
HEIGHT LIMITATIONS:
PER TABLE 504.4 THE ALLOWABLE HEIGHT OF THIS NON-SPRINKLER PROTECTED
BUILDING IS 55 FEET AND 3 STORIES. THIS IS A SINGLE STORY BUILDING WITH AN
ACTUAL HEIGHT OF 14 FEET, WHICH COMPLIES WITH THE IBC.
OCCUPANCY SEPARATION (IBC):
THIS BUILDING IS A BUSINESS OCCUPANCY WITH ACCESSORY SPACES AS ALLOWED BY
508.2.
CLASSIFICATION OF OCCUPANCY:
PER PARAGRAPH 304.1 OF THE IBC THIS BUILDING WILL CLASSIFY B (BUSINESS).
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/1
STOP
S T
O P
O
N
LY
P
A
R
K
IN
G
O
N
LY
P
A
R
K
IN
G
FORCES
SECURITY
ONLY
S T
O P
STOP
STOP
EE E
E
E
E
E
EE
E
E E
E
E
E
EE
G
G
G
DD
D
D
D
D
D
D s s ss s
T
T
I I I I I
I I I I
I II
W W
W
W
W
WW
WWW
W
W
W W
W
WW
W
W W
W W
W
W
W
W W
W
W
W W
W W
W
WW
W
W
W
WW
W
W
E
EM
W s
D D
W
T W s
Ds
G
G
D
EE
G
PVB X PVB X PVB X
P
V
B
STOP
P V
B X
P V
B X
20.0'
LANE
18.0'
18.0'
16.0'
EXIT
LANE
N: 2083218.12
E: 6302109.32
N: 2083218.12
E: 6302193.32
N: 2083287.12
E: 6302193.32
N: 2083312.12
E: 6302168.32
N: 2083312.12
E: 6302109.32
5.0'
PROPOSED 9" CURB
(APPROX. 252 LF)
(BASE BID) SEE NOTE 1.
PROPOSED VCC
PARKING LOT
(BASE BID)
ADDITIONAL 24 STALLS
VCC PARKING LOT
(BID OPTION 2)
NEW STRIPING
TYPICAL, (BID
OPTION 2)
20.0'
LANE
NOTE:
1. IF BID OPTION 2 IS EXECUTED,
PROPOSED 9" CURB AROUND
ADDITIONAL 24 STALLS SHALL NOT
BE CONSTRUCTED.
PVB X
P V
B X
PVBX
P
V
B
X
X
WW
N: 2083078.79
E: 6302165.62
N: 2083078.79
E: 6302230.93
N: 2082998.45
E: 6302230.93
N: 2082998.45
E: 6302165.62
N: 2082998.45
E: 6302170.62
N: 2083012.60
E: 6302170.62
N: 2083064.91
E: 6302170.62
N: 2083078.79
E: 6302170.78
N: 2083078.79
E: 6302178.85
N: 2083012.60
E: 6302222.93
N: 2083064.91
E: 6302222.93
-5:1
MATCH EXISTING GRADES
AFTER CONTRUCTION OF
NEW VCC FACILITY (BLDG 128)
BLDG 128
FF: 96.0
MATCH GRADE
AT EXISTING
SIDEWALK
NEW SIDEWALK
SPLASH BLOCK (TYP)
IN GRAVEL AREA
S T O
P
S T O
P
SSSSSSSSSSSSSS
SD
SD
SD SD SD SD
S D
S D
G x
G x
G x
G x
G x
G x
G x
W W W W W W W W W
W
W
W
W
W
W
W
W W
S S
S S
S S
XXXXXXX
X
XXXXXXXXXX
X
X
X
X
X
X
BLDG T135 (LOCATION TO
BE FIELD VERIFIED BY
CONTRACTING OFFICER)
1ST STREET
CHRISMAN ROAD
EXISTING SITE FENCING
TEMPORARY
VISITOR PARKING
EXISTING CONCRETE PAD
E N
N I
D
R I V
E
EMPLOYEE
GATE
POWER POLE
POWER POLE
POWER POLE
E
E
W W s s
2.5"W
6"SS
ELECTRICAL
LINE
PVB X PVB X PVB X PVB
P
A
R
K
I N
G
N: 2083456.58
E: 6302210.71
N: 2083456.58
E: 6302224.04
N: 2083500.58
E: 6302224.04
N: 2083500.58
E: 6302210.71
N: 2083505.63
E: 6302205.83
N: 2083505.63
E: 6302224.04
N: 2083451.71
E: 6302224.04
N: 2083451.71
E: 6302205.83
EXISTING SIDEWALK
BLDG132
NEW INSPECTION
BDG 131
NEW BUILDING PAD
FROM BID OPTION
VEHICLE INSPECTION LANE
VEHICLE SAFETY BUFFER
VEHICLE SAFETY BUFFER
BYPASS LANE
EXTENDED CONCRETE
WALK BID OPTION
EXTENDED CONCRETE
WALK BID OPTION
BUS SHELTER
PAD BASE BID
TO BE REMOVED
P
M
Q X
X C
S
X
X X d w g
L a s t
P l o t t e d
F i l e n a m e
A N
S x
P r o j e c t
M a n a g e m e n t
I n i t i a l s
D e s i g n e r
C h e c k e d
A p p r o v e d
KEY PLAN
U P
G R
A D
E
M
A
A
C C
E S
S
C
O N
T R
O L
P
I N
T
D L
A
D
I S
T R
I B
U T
I O
N
S A
N
J O
A Q
U I N
C
A
U S
A
R M
Y
C
O R
F
E
N G
I N
E E
R S
S A
C R
A M
E N
T
S
T R
I C
T
S A
C R
A M
E N
T O
C
A L
I F
O R
N
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
I S
S U
E
D
A T
E
M A
R K
D E
S C
R I P
T I O
N D
A T
E
US Army Corps of Engineers
Sacramento District
R
E E
T
S
E
S A
C R
A M
E N
T O
C
A
P
F
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
D R
A W
I N
G
C
O D
E
A N
S I
D
A
B
C
D
1 2 3 4 5
W
D
T R
A C
Y
A
B
T
I O
N S
CS-104
M W
D L
D D
A H
1. CONNECT VCC UTILITIES TO UTILITIES INSTALLED UNDER
THE BASE BID.
2. CONCRETE SIDEWALKS PER DETAIL A1 ON SHEET CS-516
3. BUILDING FOUNDATION INCLUDED IN THIS BID OPTION.
BID OPTION1 VCC BUILDING NOTES:
00 20' 40'
VCC PARKING - BID OPTION 2
1" = 20'
A1
00 30' 60'
VCC BUILDING - BID OPTION 1
1" = 30'
D1
00 30' 60'
TEMPORARY BADGING TRAILER - BID OPTION 3
1" = 30'
D5
1. THIS SHEET SHOWS THE APPROXIMATE LOCATION OF THE
TEMPORARY PASS AND ID CHECK POINT DURING
CONSTRUCTION SERVICES.
2. FINAL LOCATION OF THE TEMPORARY FACILITY,
RELOCATED INSPECTION CANOPY, AND ANY ADDITIONAL
CHANGES TO THE EMPLOYEE GATE DURING
CONSTRUCTION WILL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO COORDINATE WITH THE CONTRACTING
OFFICER AND SECURITY FORCES.
3. UTILITY SIZES ARE APPROXIMATE. CONTRACTOR TO VERIFY
WITH BUILDING MANUFACTURER AND COORDINATE
LOCATIONS OF CONNECTIONS WITH CONTRACTING
OFFICER.
4. TEMPORARY SIGNAGE ALONG CHRISMAN ROAD WILL BE
REQUIRED TO DIRECT TRAFFIC TO THE TEMPORARY GATE
DURING CONSTRUCTION.
5. UTILITY INFORMATION BASED ON INFORMATION PROVIDED
BY DLA TRACY. VERIFICATION IS REQUIRED PRIOR TO
CONNECTION.
6. TEMPORARY SERVICE POWER REQUIREMENTS FOR BLDG
T135 WILL BE 120/240V, 1PH, 3WR RATED FOR 200A.
COORDINATE WITH CONTRACTING OFFICER ON WHICH
POWER POLE TO TAP FOR PRIMARY POWER FOR
CONTRACTOR PROVIDED TEMPORARY TRANSFORMER.
EXISTING ELECTRICAL SERVICE CONSISTS OF 12KV AERIAL
LINES.
BID OPTION 3
TEMPORARY BADGING TRAILER NOTES:
BID
OPTION 1
BID
OPTION 3
BID
OPTION 2
BID
OPTION 6
00 10' 20'
INSPECTION BUILDING - BID OPTION 6
1" = 10'
A5
1. THE PRE-FABRICATED INSPECTION BUILDING SHALL BE
INSTALLED ON BASE BID CONCRETE BUILDING FOUNDATION
PER MANUFACTURERS RECOMMENDATIONS AND
STANDARDS.
2. THE PRE-FABRICATED INSPECTION BUILDING UTILITIES
SHALL BE CONNECTED TO THE PROVIDED UTILITY AND
ELECTRICAL CONNECTION POINTS.
3. FOUNDATION INCLUDED.
BID OPTION 6
INSPECTION BUILDING NOTES:
1. PAVE AND STRIPE PER BASE BID DETAILS: C4 ON SHEET
CS-515.
BID OPTION 2 VCC PARKING NOTES:
FOR LOCATION REFER TO DLA SITE MAP ON SHEET CG-001
E9
CS-510
R E
S P
O N
B
Q U
I R
Y
N
O V
EE E
E
E
E
EE
E
E E
E
E
E
EE
G
G
G
D
D
D
D
D
D
D s s ss s
T
T
I I I I I
I I I I
I II
W W
W
W
W
WW
WWW
W
W
W W
W
WW
W
W W
W W
W
W
W
W
W
W
W
W W
W W
W
WW
W
W
W
WW
W
W
E
EM
W s
D D
W
T W s
D s
G
G
D
E
E
G
STOP
S T
O P
O
N
L
Y
P
A
R
K
IN
G
O
N
L
Y
P
A
R
K
IN
G
F O
R C
E S
S E
C U
R
IT
Y
O N
L Y
S T
O P
EE
E
G
D ss
W
W
W
WW
W W
W W
W
W
W
W
D s
PVB
X
PVB
X
PVB
X
PVB
X
PVB
X
PVB
X
PVB
X
PVB X PVB X
P
V
B
X
PVB X
P
V
B
X
P
V
B
X
P
V
B
P
V
B
STOP
O
N
L
Y
P
A
R
K
I N
G
O
N
L
Y
P
A
R
K
I N
G
P V
B X
PVB
P V
B
X
P
V
B
P
V
B
X
PVB
(K-4)
PERIMETER SECURITY FENCE
PVB
(K-4)
PVB
(K-4)
SIDEWALK
VEHICLE
TURN OUT
BLDG 132
INSPECTION AREA
OFFICER PARKING
GENERATOR
PERIMETER
SECURITY FENCE
BLDG 129
1 LANE (12' WIDE)
ACCESS ROAD
DOUBLE SWING GATE
MAN GATE
INSPECTION
AREA ACCESS
PARKING
AREA
PVB
(K-4)
BASE BID SHELTER
PER CS-522 (BLDG 131
BID OPTION 6)
PCC PAVEMENT
DESIGN
INSPECTION AREA ENTRANCE
BOLLARD PROTECTION
ACCESS ROAD
AC PAVEMENT
9" CURB
26.6'
16.9'
GRAVEL
MEDIAN
CHRISMAN ROAD
VISITOR PARKING
GRAVEL MEDIAN
BLDG 133
BLDG 130C
BLDG 130B
BLDG
130A
4 CART SPACES
4 ADA STALLS
20 STANDARD STALLS
N: 2083142.12
E: 6302060.86
N: 2083169.37
E: 6302088.11
N: 2083170.12
E: 6302103.32
N: 2083222.90
E: 6301972.36
N: 2083252.85
E: 6301964.24
N: 2083195.87
E: 6302087.11
N: 2083195.87
E: 6302103.32
N: 2083205.12
E: 6302077.86
N: 2083328.12
E: 6302063.11
N: 2083328.12
E: 6302041.11
N: 2083302.12
E: 6302077.85
N: 2083311.37
E: 6302087.10
N: 2083312.12
E: 6302103.32
N: 2083328.87
E: 6302103.32
N: 2083328.87
E: 6302102.11
N: 2083348.12
E: 6302082.86
N: 2083318.31
E: 6301964.24
N: 2083348.26
E: 6301972.36
N: 2083460.04
E: 6301972.37
N: 2083489.98
E: 6301964.24
VEHICLE
TURN OUT
N: 2083555.43
E: 6301964.24
N: 2083585.37
E: 6301972.37
N: 2083758.01
E: 6301972.37
N: 2083917.81
E: 6302020.52
N: 2083877.33
E: 6302089.51
N: 2083741.54
E: 6302060.44
N: 2083610.63
E: 6302076.87
N: 2083606.41
E: 6302089.19
N: 2083721.08
E: 6302048.14
N: 2083721.08
E: 6302036.12
A5
CS-519
DI
CS-506
C1
CS-501
D7
CS-501
D1
CS-506
C1
CS-517
A1
CS-518
D1
CS-505
F1
CS-508
A1
CS-505
D4
CS-505
A1
CS-516
A5
CS-501
C1
CS-519
C1
CS-517
A1
CS-518
D1
CS-506
VCC PARKING
EXTENSION
(BID OPTION 2)
4-DLA CART
STALLS
SPEED
BUMP
DI
CS-506
PVB
(K-8)
A
CS-509
PVB
(K-8)
A
CS-509
N: 2083142.29
E: 6302068.86
N: 2083144.86
E: 6302248.50
PVB
(K-4)
DI
CS-506
N: 2083326.09
E: 6302245.60
N: 2083482.79
E: 6302267.44
PVB
(K-4)
DI
CS-506
PVB
(K-4)
DI
CS-506
N: 2083582.97
E: 6302193.17
N: 2083695.06
E: 6302124.31
N: 2083698.57
E: 6302071.21
N: 2083901.76
E: 6302005.46
PVB
(K-4)
D1
CS-506
N: 2083737.67
E: 6301967.89
N: 2083737.16
E: 6301924.52
N: 2083498.25
E: 6301919.13
PVB
(K-4)
D1
CS-506
N: 2083323.78
E: 6301920.90
N: 2083149.58
E: 6301922.84
PVB
(K-4)
D1
CS-506
N: 2083860.55
E: 6302085.21
P
M
Q X
X C
S
X
X X d w g
L a s t
P l o t t e d
F i l e n a m e
A N
S x
P r o j e c t
M a n a g e m e n t
I n i t i a l s
D e s i g n e r
C h e c k e d
A p p r o v e d
KEY PLAN
U P
G R
A D
E
M
A
C
E S
S
C
O N
T R
I N
T
D L
A
D
I S
T R
I B
U T
I O
N
S A
N
J O
A Q
U I N
C
A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
S A
C R
A M
E N
S
T R
I C
T
S A
C R
A M
E N
T O
C
A L
I F
O R
N
D E
S I G
N E
D
B
Y
D W
N
B
Y
C K
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
I S
S U
E
D
A T
E
M A
R K
D E
S C
R I P
T I O
N D
A T
E
US Army Corps of Engineers
Sacramento District
R
E E
T
S
S A
C R
A M
E N
T O
C
A
P
F
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
D R
A W
I N
G
C
O D
E
A N
S I
D
A
B
C
D
1 2 3 4 5
W
D
SCALE: 1" = 30'
CIVIL SITE PLAN ENLARGEMENT 2 OF 3
00 30' 60'
M A
T C
H L
I N
E
S
H E
C I V
T
E
P
L A
N
E N
L A
R G
E M
E N
CS-402
M W
D L
D D
A H
C6
CS-521
A7
CS-512
M A
T C
H L
I N
E
S
H E
1. MAXIMUM OF THREE (3) FEET BETWEEN PVB POSTS.
MINIMUM OF TWO (2) FEET BETWEEN PVB FOUNDATIONS.
NOTES:
R E
S P
O N
B
Q U
I R
Y
N
O V
ELEVATION C AND (A MIRRORED) ELEVATION D
ELEVATION B SIMILAR
FIN.
FLOOR
FIN.
CEILING
/2
FIELD INSTALLED MASONARY
VENEER FINISH
STANDING SEAM HIP ROOF
W/ EXTENDED OVERHANG
TINTED GLAZING
DURASTEEL WITH UL 752
LEVEL 3 BULLET RESISTANT
CONSTRUCTION
HVAC UNITHVAC UNIT
OPEN
/2
INFRARED RADIANT HEATER
NOTE : DOOR CLEAR
OPENING TO BE 32"
ROOF OVERHANG
C
A
D
HMD-SL-BR
HMD-SL-BR
B
HVAC
(HIGH)
10' - 0"
3' - 2"3' - 8"3' - 2"
3"x3" ANCHOR TAB W/
3/4" DIA. HOL (TYP. 4)
24" DEEP STAINLESS
STEEL WORK COUNTER
1. THE ENTIRE DESIGN OF THIS BUILDING SHALL BE
CONSIDERED "DELEGATED ENGINEERED SYSTEMS" AS
DEFINED IN SECTION 2-1.1.1 OF UFC 3-301-01. SEE PROJECT
SPECIFICATION FOR PREMANUFACTURED STRUCTURES.
2. THE CONTRACTOR SHALL SUBMIT A COMPLETE SET
OF SHOP DRAWINGS (INCLUSIVE OF MECHANICAL,
ELECTRICAL AND STRUCTURAL DESIGN DRAWINGS) TO
ARCHITECT/ENGINEER FOR REVIEW PRIOR TO THE BUILDING
FABRICATION. REVIEW OF SHOP DRAWINGS BY THE
ARCHITECT/ENGINEER IS FOR GENERAL COMPLIANCE WITH
THE CONTRACT DOCUMENTS ONLY. THE CONTRACTOR WILL
REMAIN RESPONSIBLE FOR ALL ERRORS OF DETAILING,
FABRICATION, AND FOR CORRECT FITTING OF ALL
COMPONENTS AND MEMBERS INCLUDING COORDINATION
WITH OTHERS TRADES. SHOP DRAWING SUBMITTALS
PROCESSED BY THE ENGINEER DO NOT CONSTITUTE CHANGE
ORDER. ANY PROPOSED CHANGES MUST BE SUBMITTED IN A
LETTER OR DETAIL TO THE ARCHITECT/ENGINEER FOR
APPROVAL. NOTE REFER TO NOTE NO. 7 BELOW FOR
ADDITIONAL MECHANICAL REQUIREMENTS.
3. ELECTRICAL, MECHANICAL, COMMUNICATIONS AND
SECURITY CONTROLS SYSTEMS SWITCHES WILL BE WALL
MOUNTED. PREMANUFACTURED STRUCTURES BUILDING
MANUFACTURER SHALL PROVIDE ELECTRICAL, MECHANICAL,
COMMUNICATIONS AND SECURITY CONTROLS SYSTEMS
INFRASTRUCTURE WITH IN-WALL CONDUIT PATHWAYS, AND
CONTRACTOR SHALL CONNECT AND ANCHOR SURFACE
MOUNTED CONTROLS SWITCHES AND PLATES AS REQUIRED
FOR CONTROLS EQUIPMENT CONNECTIVITY PER ELECTRICAL
AND MECHANICAL DRAWINGS AND SPECIFICATIONS FOR
PERFORMANCE REQUIREMENTS. TYPICAL MOUNTING HEIGHT
RANGE FOR CONTROLS IS BETWEEN 36" AND 48" ABOVE
FINISH FLOOR. SHOP DRAWINGS SHALL INCLUDE TYPE AND
SIZE OF IN-WALL CONDUIT PATHWAYS AND PROPOSED
TERMINIATIONS LOCATIONS.
4. ANCHORING WITH EXPANSION ANCHORS SHALL BE
DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17,
ASSUMING CRACKED CONCRETE CONDITIONS. EXPANSION
BOLTS TO BE OF DIAMETER, EMBEDMENT AND FINISH AS
INDICATED ON THE DRAWINGS AND SPECIFICATIONS. UNLESS
NOTED OTHERWISE, USE 1/2" DIA. CARBON STEEL BOLTS WITH
3.5" EFFECTIVE EMBEDMENT. LOAD VALUES FOR KB-TZ AS
MANUFACTURED BY HILTI HAVE BEEN USED AS THE BASIS OF
DESIGN. PROVIDE ANY APPROPRIATE EXPANISION ANCHOR
WITH EQUIVALENT SHEAR AND TENSION CAPACITIES AFTER
MODIFICATION DUE TO EMEBEMENT, SPACING AND EDGE
DISTANCES. LOAD CAPACITIES SHALL BE BASED ON TESTS IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC 193. INSTALL
ANCHORS PER THE MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS. OTHER AVAILABLE MANUFACTURERS
INCLUDE SIMPSON AND POWERS FASTENERS. CONCRETE IN
WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR
WEIGHT (145 PCF, MIN.) WITH A MINIMUM 28 DAY
COMPRESSIVE STRENGTH OF 4,000 PSI. ANCHOR DIAMETER
REFERS TO THE THREAD SIZE.
5. ANCHORING WITH ADHESIVE ANCHOR SIZES SHALL BE
BASED ON HILTI HIT HY-200, ADHESIVE ANCHOR SYSTEM WITH
HAS THREADED ROD. ANY SYSTEM CONSISTING OF AN
EQUIVALENT TWO-COMPONENT STRUCTURAL GRADE
INJECTION MATERIAL CONFORMING TO ASTM C881 THAT
MEETS OR EXCEEDS THE CAPACITIES OF THE HILTI SYSTEM
AND IS APPROVED BY THE STRUCTUAL ENGINEER MAY BE
USED. ANCHOR SYSTEM MUST BE SHOWN TO HAVE
APPROVAL FROM THE ICC WITH A DOCUMENTED ICC
EVALUATION SERVICES REPORT. EXPOXY ANCHORS SHALL BE
DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17
ASSUMING CRACKED CONCRETE CONDITIONS. CONCRETE IN
WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR
WEIGHT (145 PCF MIN) WITH A MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF 4,000 PSI. TESTING OF CORE SAMPLES TO BE
PERFORMED BY THE CONTRACTOR AS NEEDED TO
DEMONSTRATE EXISTING CONCRETE STRENGTH, OR
CONSTRACTOR TO OBTAIN RECORDS OF ORIGINAL TEST
SAMPLES. ALL EPOXY ANCHOR INSTALLATIONS SHALL
COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS
AND SPECIFICATIONS. DUST SHALL BE BLOWN FROM THE
HOLE WITH COMPRESSED AIR TO ENSURE PROPER ANCHOR
SEATING DEPTH AND TO PROVIDE A CLEAN BONDING
SURFACE. ADDITIONALLY, THE HOLE SHALL BE BRUSHED WITH
A NYLON BRUSH THEN BLOWN AGAIN WITH COMPRESSED AIR.
EPOXY SHALL ONLY BE APPLIED TO CLEAN DRY SURFACES.
BASE MATERIAL TEMPERATURE MUST NOT BE BELOW 40 F.
6. THE BUILDING WILL ARRIVE ON-SITE AS A FULLY
ASSEMBLED PREMANUFACTURED STRUCTURE, AND THE
CONTRACTOR IS REPSONSIBLE TO PROVIDE A CRANE OR LIFT
SYSTEM PER MANUFACTURER'S REQUIREMENTS TO PLACE
THE BUILDING IN THE DESIGNED LOCATION ONTO A
CONCRETE PAD WHERE IT WILL BE PREMANANTLY
ANCHORED; SEE CIVIL DRAWINGS FOR LOCATION
7. PROVIDE COMPLETE THRU-WALL HEATING,
VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEM TO
MAINTAIN CONDITIONS INDOORS AT 78F DRY BULB/50%
RELATIVE HUMIDITY MAXIMUM IN THE SUMMER AND 68 F DRY
BULB/30% RELATIVE HUMIDITY MINIMUM IN THE WINTER.
OUTDOOR CONDITIONS ARE 97.9 F DRY BULB/68.8 F WET BULB
IN THE SUMMER AND 32.7 F DRY BULB IN THE WINTER.
PROVIDE ASHRAE 62.1-2010 OUTDOOR AIR (VENTILATION) TO
THE SPACE THROUGH THE HVAC UNIT. HVAC COIL CAPACITY
CALCULATIONS SHALL INCLUDE HEAT LOSSES DUE TO
VENTILATION AIR, OCCUPANTS, OFFICE EQUIPMENT,
LIGHTING, ENVELOPE INSULATION VALUE, ETC. PROVIDE
SEISMIC BRACING ON EQUIPMENT, DUCTWORK, PIPING, ETC.
AS REQUIRED. ALSO PROVIDE ELECTRIC INFRARED RADIANT
HEATER ON EXTERIOR OF GUARD BOOTH, MOUNTED
DIRECTLY OVER EXIT DOORWAY AT A 45-DEGREE ANGLE WITH
MANUAL OCCUPANT ON/OFF DIAL AND TIMER INSIDE THE
GUARD BOOTH, ADJACENT TO DOOR. UNIT CAPACITY SHALL
BE 1,500 WATTS (5,118 BTU) AND RATED FOR OUTDOOR USE.
INSTALL ALL HVAC EQUIPMENT PER MANUFACTURER
RECOMMENDATIONS. SEE MECHANICAL-SERIES DRAWING
SHEET M-001 FOR VISITOR CONTROL CENTER AND DIVISION
22/23 SPECIFICATIONS FOR GENERAL NOTES REGARDING THE
HVAC PROJECT SCOPE AND REQUIREMENTS.
8. FINISH AND COLOR SELECTIONS FOR INTERIOR AND
EXTERIOR SURFACES, INCLUSIVE OF ROOFING, WALL PANELS,
DOORS, WINDOWS, INTERIOR WALL PANELS, CASEWORK,
COUNTERS, AND OTHER ELEMENTS THAT WILL BE VISIBLE TO
THE PUBLIC, WILL BE CHOSEN AS PART OF THE SHOP
DRAWING REVIEW PROCESS, AND WILL BE SELECTED FROM
THE BUILDINGS MFG'S. STANDARD COLOR SELECTIONS,
UNLESS OTHERWISE DIRECTED ON THE DRAWINGS.
UL 752 LEVEL 3 BULLET RESISTANT CONSTRUCTION, SLIDING DOOR, TINTED GLAZING, FACTORY ADHERED BRICK FINISH, THRU WALL HAVC, EXTERIOR LIGHTING AND STANDING SEAM HIP ROOF WITH EXTENDED OVERHANG
1. ROOF INCLUDES A FULLY INSTALLED STANDING SEAM METAL ROOF.
2. A CONTINUOUS SHEET OF HARDENED BALLISTIC RATED STEEL IS USED FOR EACH WALL TO CREATE A SEAMLESS BALLISTIC BARRIER FROM GRADE TO THE ROOF LINE.
3. BULLET RESISTANT STEEL TOP-SUSPENDED SLIDING DOOR.
4. DURABLE STEEL CONSTRUCTION CONSISTING OF STRUCTURAL ASTM A500 GRADE B WELDED STEEL EXTERIOR WALL PANELS AND 16 GUAGE INTERIOR WALL PANELS.
5. FULLY INSULATED WALLS AND CEILING.
6. WINDOWS ARE CLEAR OR TINTED GLAZING AND SLIDING TYPE.
7. 1 1/2" SOLID INSULATING FLOOR STRUCTURE WITH MAINTENANCE-FREE ALUMINUM TREADPLATE FINSIHED SURFACE.
8. ALL STEEL SURFACES ARE ELECTROSTATICALLY PAINTED WITH RUST INHIBITIVE EPOXY PRIMER AND HAVE A FINISHED COAT OF AN AIR DRY INDUSTRIAL ARCYLIC PAINT.
9. EXTERIOR FACADE FINISH COLORS TO MATCH BUILDING 128 IN ALL RESPECTS.
GUARD BOOTH DESIGN CRITERIA
DEGREES F
WET BULB
51.5
DEGREES F
WET BULB
% RELATIVE
HUMIDITY
% RELATIVE
HUMIDITY
SUMMER 78.0
DEGREES F
DRY BULB
WINTER 68.0
DEGREES F
DRY BULB
NOTES: 1. SETPOINT DATA BASED ON UFC 3-410-01 REQUIREMENTS.
INDOOR DESIGN CONDITIONS
68.8
DEGREES F
WET BULB
SUMMER 97.9
DEGREES F
DRY BULB
WINTER 32.7 DEGREES F
NOTES: 1. WEATHER DATA BASED ON ASHRAE CLIMACTIC DATA,
UFC 3-400-02, AND UFC 3-410-01 REQUIREMENTS.
OUTDOOR DESIGN CONDITIONS
COLOR FINISH NOTES:
1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)
2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.
3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.
4. DOORS AND FRAMES TO MATCH ROOFING COLOR.
5. WINDOW FRAMES TO MATCH ROOFING COLOR.
6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
SHEET NOTES
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_GUARD_BOOTH.rvt
11/21/2019 3:54:48 PM
262207
A-501
BLDG 130
A, B, & C
P L
A N
V
IE
W
E L
E V
A T
IO
N
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A L
IF
O
R N
IA
-2
J
U L Y
W -1
-D
-0
RTA DESIGN - 22 JULY 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
A
B
C
G
U A
R D
B O
O T
H
A C
S G
/s A
H
1/2" = 1'-0"A-501
ELEVATIONS2
1/2" = 1'-0"A-501
PLAN VIEW1
0 1' 2' 4'
INTERNATIONAL BUILDING CODE ANALYSIS:
CONSTRUCTION TYPE:
A. TYPE V-NS
B. NON-RATED
C. UNPROTECTED STRUCTURE
D. NON-SPRINKLER
OCCUPANCY TYPE: "B"
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/1 /1
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/2 /1
** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE
MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.
WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE
MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE
PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE
SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED
PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR
SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY
VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER
AND THE METAL PANELS ABOVE.
FINISH CEILING
8' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.W.
9' - 2"
T.O.S.
0' - 0"
SEE 5/A-201 FOR GUTTER DETAILS
FINISH CEILING
8' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.W.
9' - 2"
T.O.S.
0' - 0"
AB
FINISH CEILING
8' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.W.
9' - 2"
T.O.S.
0' - 0"
1 2
FOUNDATION PADALL DOORS TO BE BALLISTIC
RATED & MIN 3070, TYP.
FIELD INSTALLED MASONRY VENEER TO
MATCH VCC COLOR SELECTION.
INSTALLED BY GENERAL CONTRACTOR
STANDING SEAM METAL
ROOF FULLY INSULATED
TYP BALLISTIC RATED
WINDOW. MIN 3040 ALL
WINDOWS
BALLISTIC RATED MTL
WALL PANELS
T
O C
L
12" TO CL
24" TO CL
#12 BUILDING SIGN CENTERED ON
FINISH CEILING. SEE 12/AI-501
ROOM SIGN TYP. SEE #11/AI-
501 FURNISHED & INSTALLED
BY GENERAL CONTRACTOR
SEE 5/A-201 FOR GUTTER DETAILS
T
O C
L
EQEQ
ROOM SIGN TYP. SEE #10/AI-
501 FURNISHED & INSTALLED
BY GENERAL CONTRACTOR
ROOM SIGN TYP. SEE #6/AI-
501 FURNISHED & INSTALLED
BY GENERAL CONTRACTOR
12" TO CL
FINISH CEILING
8' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.W.
9' - 2"
T.O.S.
0' - 0"
A B
24" TO CL
#12 BUILDING SIGN CENTERED ON
FINISH CEILING. SEE 12/AI-501
COLOR FINISH NOTES:
1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)
2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.
3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.
4. DOORS AND FRAMES TO MATCH ROOFING COLOR.
5. WINDOW FRAMES TO MATCH ROOFING COLOR.
6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.
HEAVY DUTY SUPPORT BRACKETS
@ 30" CENTERS. (OPTIONAL)
HEAVY DUTY INTERIOR STRAPS
@ 30" CENTER.
GUTTER PROFILE 10' LENGTH, 1"
TELESCOPING JOINTS.
#10 X 2" S.S. WOOD SCREWS
1-1/2" STAINLESS NAILS OR #10
X 1 1/2" S.S. WOOD SCREWS.
ALUMINUM RIVET TO SECURE
INTERIOR STRAP OT GUTTER.
0' - 5"
0' - 4"
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_INSPECTION_FACILITY.rvt
11/21/2019 3:56:50 PM
261217
A-201
BLDG 131
E X
T E
R
IO
R E
L E
V A
T
IO
N S
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A L
IF
O
R N
IA
-2
J
U N
E
W -1
-D
-0
100% DESIGN - 14 JUNE 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
I N
S P
E C
T
IO
N B
U
IL
D
IN
G
B
ID
O P
T
IO
N
J V
S M
S G
A H
3/8" = 1'-0"1
WEST ELEVATION
3/8" = 1'-0"2
NORTH ELEVATION
3/8" = 1'-0"3
EAST ELEVATION
3/8" = 1'-0"4
SOUTH ELEVATION
3" = 1'-0"5
INDUSTRIAL SERIES COMMERCIAL
GUTTER SYSTEM G1-R6
** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE
MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.
WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE
MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE
PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE
SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED
PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR
SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY
VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER
AND THE METAL PANELS ABOVE.
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/2
T.O.W.
9' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.S.
0' - 0"
FINISH CEILING
8' - 2"
FOUNDATION PADFIELD INSTALLED MASONRY
VENEER TO MATCH VCC
COLOR SELECTION
STANDING SEAM METAL
ROOF FULLY INSULATED
TYP BALLISTIC RATED WINDOW.
MIN 3040 ALL WINDOWS
BALLISTIC RATED MTL
WALL PANELS
ALL DOORS TO BE BALLISTIC
RATED & MIN 3070, TYP.
SEE 5/A-201 FOR GUTTER PROFILE
#12 BUILDING SIGN CENTERED ON
FINISH CEILING. SEE 12/AI-501
ROOM SIGN TYP. SEE #11/AI-
501 FURNISHED & INSTALLED
BY GENERAL CONTRACTOR
T
O C
L
48" TP CL
12" TO CL
T
O C
L
ROOM SIGN TYP. SEE #10/AI-
501 FURNISHED & INSTALLED
BY GENERAL CONTRACTOR
EQEQ
ROOM SIGN TYP. SEE #6/AI-
501 FURNISHED & INSTALLED
BY GENERAL CONTRACTOR
AB
T.O.W.
9' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.S.
0' - 0"
FINISH CEILING
8' - 2"
A B
T.O.W.
9' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.S.
0' - 0"
FINISH CEILING
8' - 2"
2 1
T.O.W.
9' - 2"
FINISH FLOOR
LINE
0' - 2"
T.O.S.
0' - 0"
FINISH CEILING
8' - 2"
SEE 5/A-201 FOR GUTTER DETAIL
12" TO CL
T
O C
L
COLOR FINISH NOTES:
1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)
2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.
3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.
4. DOORS AND FRAMES TO MATCH ROOFING COLOR.
5. WINDOW FRAMES TO MATCH ROOFING COLOR.
6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.
HEAVY DUTY SUPPORT BRACKETS
@ 30" CENTERS. (OPTIONAL)
HEAVY DUTY INTERIOR STRAPS
@ 30" CENTER.
GUTTER PROFILE 10' LENGTH, 1"
TELESCOPING JOINTS.
#10 X 2" S.S. WOOD SCREWS
1-1/2" STAINLESS NAILS OR #10
X 1 1/2" S.S. WOOD SCREWS.
ALUMINUM RIVET TO SECURE
INTERIOR STRAP OT GUTTER.
0' - 5"
0' - 4"
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_GATEHOUSE.rvt
11/21/2019 3:58:36 PM
261240
A-201
BLDG 133
E X
T E
R
IO
R E
L E
V A
T
IO
N S
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A
-2
J
U N
E
W -1
-D
100% DESIGN - 14 JUNE 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
G A
T E
H O
U S
E
J V
S M
S G
A H
3/8" = 1'-0"2
EAST ELEVATION
3/8" = 1'-0"1
NORTH ELEVATION
3/8" = 1'-0"3
SOUTH ELEVATION
3/8" = 1'-0"4
WEST ELEVATION
3" = 1'-0"5
INDUSTRIAL SERIES COMMERCIAL
GUTTER SYSTEM G1-R6
** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE
MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.
WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE
MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE
PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE
SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED
PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR
SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY
VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER
AND THE METAL PANELS ABOVE.
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/2 /1
22"
3"x3" ANCHOR TAB W/
3/4"DIA. HOLE (TYP. 4)
ROOF OVERHANG
C
A
D
HMD-SL-BR
B
HVAC
(HIGH)
HMD-SL-BR
6' - 0"
32" CLR OPNG
32" CLR OPNG
ELEVATION A AND (C MIRRORED) ELEVATION D (B MIRRORED W/O HVAC UNIT)
FIN.
FLOOR
FIN.
CEILING
/2
STANDING SEAM HIP ROOF
W/ EXTENDED OVERHANG.
DURASTEEL WITH UL 752
LEVEL 3 BULLET RESISTANT
CONSTRUCTION.
FIELD APPLIED MASONRY
VEENER FINISH
TINTED GLAZING
HVAC UNIT
SLIDING DOOR W/ MIN
32" CLR OPENING WHEN
DOOR IS OPEN
1. THE ENTIRE DESIGN OF THIS BUILDING SHALL BE
CONSIDERED "DELEGATED ENGINEERED SYSTEMS" AS
DEFINED IN SECTION 2-1.1.1 OF UFC 3-301-01. SEE PROJECT
SPECIFICATION FOR PREMANUFACTURED STRUCTURES.
2. THE CONTRACTOR SHALL SUBMIT A COMPLETE SET
OF SHOP DRAWINGS (INCLUSIVE OF MECHANICAL,
ELECTRICAL AND STRUCTURAL DESIGN DRAWINGS) TO
ARCHITECT/ENGINEER FOR REVIEW PRIOR TO THE BUILDING
FABRICATION. REVIEW OF SHOP DRAWINGS BY THE
ARCHITECT/ENGINEER IS FOR GENERAL COMPLIANCE WITH
THE CONTRACT DOCUMENTS ONLY. THE CONTRACTOR WILL
REMAIN RESPONSIBLE FOR ALL ERRORS OF DETAILING,
FABRICATION, AND FOR CORRECT FITTING OF ALL
COMPONENTS AND MEMBERS INCLUDING COORDINATION
WITH OTHERS TRADES. SHOP DRAWING SUBMITTALS
PROCESSED BY THE ENGINEER DO NOT CONSTITUTE CHANGE
ORDER. ANY PROPOSED CHANGES MUST BE SUBMITTED IN A
LETTER OR DETAIL TO THE ARCHITECT/ENGINEER FOR
APPROVAL. NOTE REFER TO NOTE NO. 7 BELOW FOR
ADDITIONAL MECHANICAL REQUIREMENTS.
3. ELECTRICAL, MECHANICAL, COMMUNICATIONS AND
SECURITY CONTROLS SYSTEMS SWITCHES WILL BE WALL
MOUNTED. PREMANUFACTURED STRUCTURES BUILDING
MANUFACTURER SHALL PROVIDE ELECTRICAL, MECHANICAL,
COMMUNICATIONS AND SECURITY CONTROLS SYSTEMS
INFRASTRUCTURE WITH IN-WALL CONDUIT PATHWAYS, AND
CONTRACTOR SHALL CONNECT AND ANCHOR SURFACE
MOUNTED CONTROLS SWITCHES AND PLATES AS REQUIRED
FOR CONTROLS EQUIPMENT CONNECTIVITY PER ELECTRICAL
AND MECHANICAL DRAWINGS AND SPECIFICATIONS FOR
PERFORMANCE REQUIREMENTS. TYPICAL MOUNTING HEIGHT
RANGE FOR CONTROLS IS BETWEEN 36" AND 48" ABOVE
FINISH FLOOR. SHOP DRAWINGS SHALL INCLUDE TYPE AND
SIZE OF IN-WALL CONDUIT PATHWAYS AND PROPOSED
TERMINIATIONS LOCATIONS.
4. ANCHORING WITH EXPANSION ANCHORS SHALL BE
DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17,
ASSUMING CRACKED CONCRETE CONDITIONS. EXPANSION
BOLTS TO BE OF DIAMETER, EMBEDMENT AND FINISH AS
INDICATED ON THE DRAWINGS AND SPECIFICATIONS. UNLESS
NOTED OTHERWISE, USE 1/2" DIA. CARBON STEEL BOLTS WITH
3.5" EFFECTIVE EMBEDMENT. LOAD VALUES FOR KB-TZ AS
MANUFACTURED BY HILTI HAVE BEEN USED AS THE BASIS OF
DESIGN. PROVIDE ANY APPROPRIATE EXPANISION ANCHOR
WITH EQUIVALENT SHEAR AND TENSION CAPACITIES AFTER
MODIFICATION DUE TO EMEBEMENT, SPACING AND EDGE
DISTANCES. LOAD CAPACITIES SHALL BE BASED ON TESTS IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC 193. INSTALL
ANCHORS PER THE MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS. OTHER AVAILABLE MANUFACTURERS
INCLUDE SIMPSON AND POWERS FASTENERS. CONCRETE IN
WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR
WEIGHT (145 PCF, MIN.) WITH A MINIMUM 28 DAY
COMPRESSIVE STRENGTH OF 4,000 PSI. ANCHOR DIAMETER
REFERS TO THE THREAD SIZE.
5. ANCHORING WITH ADHESIVE ANCHOR SIZES SHALL BE
BASED ON HILTI HIT HY-200, ADHESIVE ANCHOR SYSTEM WITH
HAS THREADED ROD. ANY SYSTEM CONSISTING OF AN
EQUIVALENT TWO-COMPONENT STRUCTURAL GRADE
INJECTION MATERIAL CONFORMING TO ASTM C881 THAT
MEETS OR EXCEEDS THE CAPACITIES OF THE HILTI SYSTEM
AND IS APPROVED BY THE STRUCTUAL ENGINEER MAY BE
USED. ANCHOR SYSTEM MUST BE SHOWN TO HAVE
APPROVAL FROM THE ICC WITH A DOCUMENTED ICC
EVALUATION SERVICES REPORT. EXPOXY ANCHORS SHALL BE
DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17
ASSUMING CRACKED CONCRETE CONDITIONS. CONCRETE IN
WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR
WEIGHT (145 PCF MIN) WITH A MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF 4,000 PSI. TESTING OF CORE SAMPLES TO BE
PERFORMED BY THE CONTRACTOR AS NEEDED TO
DEMONSTRATE EXISTING CONCRETE STRENGTH, OR
CONSTRACTOR TO OBTAIN RECORDS OF ORIGINAL TEST
SAMPLES. ALL EPOXY ANCHOR INSTALLATIONS SHALL
COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS
AND SPECIFICATIONS. DUST SHALL BE BLOWN FROM THE
HOLE WITH COMPRESSED AIR TO ENSURE PROPER ANCHOR
SEATING DEPTH AND TO PROVIDE A CLEAN BONDING
SURFACE. ADDITIONALLY, THE HOLE SHALL BE BRUSHED WITH
A NYLON BRUSH THEN BLOWN AGAIN WITH COMPRESSED AIR.
EPOXY SHALL ONLY BE APPLIED TO CLEAN DRY SURFACES.
BASE MATERIAL TEMPERATURE MUST NOT BE BELOW 40 F.
6. THE BUILDING WILL ARRIVE ON-SITE AS A FULLY
ASSEMBLED PREMANUFACTURED STRUCTURE, AND THE
CONTRACTOR IS REPSONSIBLE TO PROVIDE A CRANE OR LIFT
SYSTEM PER MANUFACTURER'S REQUIREMENTS TO PLACE
THE BUILDING IN THE DESIGNED LOCATION ONTO A
CONCRETE PAD WHERE IT WILL BE PREMANANTLY
ANCHORED; SEE CIVIL DRAWINGS FOR LOCATION.
7. PROVIDE COMPLETE THRU-WALL HEATING,
VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEM TO
MAINTAIN CONDITIONS INDOORS AT 78F DRY BULB/50%
RELATIVE HUMIDITY MAXIMUM IN THE SUMMER AND 68 F DRY
BULB/30% RELATIVE HUMIDITY MINIMUM IN THE WINTER.
OUTDOOR CONDITIONS ARE 97.9 F DRY BULB/68.8 F WET BULB
IN THE SUMMER AND 32.7 F DRY BULB IN THE WINTER.
PROVIDE ASHRAE 62.1-2010 OUTDOOR AIR (VENTILATION) TO
THE SPACE THROUGH THE HVAC UNIT. HVAC COIL CAPACITY
CALCULATIONS SHALL INCLUDE HEAT LOSSES DUE TO
VENTILATION AIR, OCCUPANTS, OFFICE EQUIPMENT,
LIGHTING, ENVELOPE INSULATION VALUE, ETC. PROVIDE
SEISMIC BRACING ON EQUIPMENT, DUCTWORK, PIPING, ETC.
AS REQUIRED. SEE MECHANICAL-SERIES DRAWING SHEET
M-001 FOR VISITOR CONTROL CENTER AND DIVISION 22/23
SPECIFICATIONS FOR GENERAL NOTES REGARDING THE HVAC
PROJECT SCOPE AND REQUIREMENTS.
8. FINISH AND COLOR SELECTIONS FOR INTERIOR AND
EXTERIOR SURFACES, INCLUSIVE OF ROOFING, WALL PANELS,
DOORS, WINDOWS, INTERIOR WALL PANELS, CASEWORK,
COUNTERS, AND OTHER ELEMENTS THAT WILL BE VISIBLE TO
THE PUBLIC, WILL BE CHOSEN AS PART OF THE SHOP
DRAWING REVIEW PROCESS, AND WILL BE SELECTED FROM
THE BUILDINGS MFG'S. STANDARD COLOR SELECTIONS,
UNLESS OTHERWISE DIRECTED ON THE DRAWINGS.
UL 752 LEVEL 3 BULLET RESISTANT CONSTRUCTION, SLIDING DOOR, TINTED GLAZING, FACTORY ADHERED BRICK FINISH, THRU WALL HAVC, EXTERIOR LIGHTING AND STANDING SEAM HIP ROOF WITH EXTENDED OVERHANG
1. ROOF: INSULATED STANDING SEAM METAL ROOF.
2. A CONTINUOUS SHEET OF HARDENED BALLISTIC RATED STEEL IS USED FOR EACH WALL TO CREATE A SEAMLESS BALLISTIC BARRIER FROM GRADE TO THE ROOF LINE.
3. BULLET RESISTANT STEEL SWING DOOR.
4. DURABLE STEEL CONSTRUCTION CONSISTING OF STRUCTURAL ASTM A500 GRADE B WELDED STEEL EXTERIOR WALL PANELS AND 16 GUAGE INTERIOR WALL PANELS.
5. FULLY INSULATED WALLS AND CEILING.
6. WINDOWS ARE CLEAR OR TINTED GLAZING AND SLIDING TYPE.
7. 1 1/2" SOLID INSULATING FLOOR STRUCTURE WITH MAINTENANCE-FREE ALUMINUM TREADPLATE FINSIHED SURFACE.
8. ALL STEEL SURFACES ARE ELECTROSTATICALLY PAINTED WITH RUST INHIBITIVE EPOXY PRIMER AND HAVE A FINISHED COAT OF AN AIR DRY INDUSTRIAL ARCYLIC PAINT.
9. EXTERIOR FACADE FINISH COLORS TO MATCH BUILDING 128 IN ALL RESPECTS.
10. GUN PORTS SHALL BE PROVEDED ON EACH FACE OF THE OVERWATCH.
11. ALL GUN PORTS SHALL BE USABLE FOR BOTH HANDGUN AND SHOULDER FIRED WEAPONS. GUNPORT DESIGN SHALL NOT REQUIRE WEAPONS TO BE ORIENTED IN AN UNUSUAL WAY (EG. GUNPORT BEING PLACED IMMEDIATELY ABOVE COUNTER AND COUNTER INTERFERING WITH VERTICAL ORIENTATiON OF PISTOL MAGAZINE.)
OVERWATCH DESIGN CRITERIA
DEGREES F
WET BULB
51.5
DEGREES F
WET BULB
% RELATIVE
HUMIDITY
% RELATIVE
HUMIDITY
SUMMER 78.0
DEGREES F
DRY BULB
WINTER 68.0
DEGREES F
DRY BULB
NOTES: 1. SETPOINT DATA BASED ON UFC 3-410-01 REQUIREMENTS.
INDOOR DESIGN CONDITIONS
68.8
DEGREES F
WET BULB
SUMMER 97.9
DEGREES F
DRY BULB
WINTER 32.7 DEGREES F
NOTES: 1. WEATHER DATA BASED ON ASHRAE CLIMACTIC DATA,
UFC 3-400-02, AND UFC 3-410-01 REQUIREMENTS.
OUTDOOR DESIGN CONDITIONS
COLOR FINISH NOTES:
1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)
2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.
3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.
4. DOORS AND FRAMES TO MATCH ROOFING COLOR.
5. WINDOW FRAMES TO MATCH ROOFING COLOR.
6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
L
S T
R E
E T
S
T E
S A
C R
A M
E N
T O
C
A
P
-4
-5
F
-4
-5
SHEET NOTES
BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_OVERWATCH.rvt
11/21/2019 4:00:01 PM
261254
A-501
BLDG 134
P R
E F
A B
R
IC
A T
E D
O V
E R
W A
T C
H
D L
A D
IS
T
R
IB
U T
IO
N
S A
N J
O A
Q U
IN
C
A S
A C
R A
M E
N T
O D
IS
T
R
IC
T
S A
C R
A M
E N
T O
C
A L
IF
O
R N
IA
-2
J
U N
E
W -1
-D
-0
100% DESIGN - 14 JUNE 2019
U P
G R
A D
E M
A
IN
A C
C E
S S
C O
N T
R O
L P
O
IN
T
P
D D
C X
B L
D G
O V
E R
W A
T C
H B
U
IL
D
IN
G
A C
S M
S G
A H
1/2" = 1'-0"A-501
OVERWATCH PLAN VIEW1
1/2" = 1'-0"A-501
OVERWATCH ELEVATIONS2
0 1' 2' 4'
NOTE: OVERWATCH DOOR REQUIREMENTS.
PROVIDE A MINIMUM 32" CLEAR OPENING (CLEAR WHEN DOOR IS FULLY
OPEN). PROVIDE A MIN 6'-8' HIGH SLIDING DOOR AS SHOWN. THAT WHEN
FULLY RETRACTED WILL PROVIDE THE REQUIRED 32" CLEAR OPENING.
THE DOOR SHALL BE DESIGNED SUCH THAT WHEN FULLY CLOSED, THE
DOOR SHALL OVERLAP THE BACK JAMB A MIN OF 1.5" AS TO NOT ALLOW
OBJECTS TO FREELY PASS BETWEEN THE JAMB AND FRAME.
OVERWATCH BUILDING IS CURRENTLY DESIGNED AT 6'-0" x 6'-0" FOR A
GROSS TOTAL OF 36 SF. PRE 10 UFC 2853, THE BUILDING AREA MAY BE
INCREASED BY 10 PERCENT TO A MAXIMUM OF 39.5 SF (AND OR
EXTENDED A DISTANCE OF 4.92") TO ALLOW FOR MEETING THE MINMUM
DOOR CLEARANCES.
INTERNATION BUILDING CODE ANALYSIS:
CONSTRUCTION TYPE:
A. TYPE V-NS
B. NON-RATED
C. UNPROTECTED STRUCTURE
D. NON-SPRINKLER
OCCUPANCY TYPE: "B" 2
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/1 /1
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/1 /1
R
E V
IS
IO
N S
P E
R I
N Q
U
IR
Y I
D
/2 /1
** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE
MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.
WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE
MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE
PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE
SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED
PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR
SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY
VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER
AND THE METAL PANELS ABOVE.
G
PV
B
X
PVB X PVB X PVB
X
X X
X
XXXXX
X
XXX
PVB
X
PVB
XPVB
X
BLDG 128
VISITOR CONTROL CENTER
(BID OPTION 1)
(E) V5 (E5)
(E) V7 (E7)
(E) E8
BLDG 29
BLDG 6
BLDG 30
(E) V24 (N15)
W/34A
(E) POLE
3/21
D S
TR
EE
T
3RD STREET
W/35 W/35A
W/34
2ND STREET
CHRISMAN ROAD
C(UG)
(N) UG CONDUIT (2) 1-INCH TO
PULL BOX ON LIGHT POLE
(N) UG CONDUIT (1) 1-INCH
TO GATE OPERATORS
(N) UG CONDUIT
(2) 4-INCH
C(UG)
(N) UG CONDUIT (1) 2-INCH
TO NEW HANDHOLE
C (U
G
C (U
G
C (U
G
C(UG) C(UG) C(UG) C(UG) C(UG) C(UG) C(UG) C(UG)
C (U
G
C (U
G
C (U
G
C (U
G
C (U
G
C (U
G
C (U
G
C (U
G
C(UG) C(UG) C(UG) C(UG)
C(UG) C(UG)
2ND FLOOR
NETWORK ROOM
FIBER
TERMINATION
CABINET
EXTERIOR MOUNTED
PULL BOX
C(UG)
C(UG)
2 3
(N) UG CONDUIT
(2) 4-INCH
C(UG
6 81 6
4 6
9 10
(N) CB7
(N) CB6
(E) V6 (E6)
(N) CB8
4 6
KEY PLAN
U
PG
R
AD
E M
AI
N
A C
C
ES
S C
O N
TR
O
L
PO
IN
T
D
LA
D
IS
TR
IB
U
TI
O N
SA
N J
O
AQ
U
IN
, C A
SA
C
R A
M E
N
TO
D
IS
TR
IC
T
SA
C R
AM
EN
TO
, C
AL
IF
O R
N
IA
-2
L S
TR
EE
T, S
TE
SA
C R
A M
EN
TO
, C A
P:
-4
-5
F:
6-
4-
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F
EN
G
IN
EE
R
S
D R
A W
N B
Y:
D E
S
IG
N E
D B
Y:
SU
B
M
IT
TE
D
B Y:
SI
ZE
C H
E C
K E
D B
Y:
AN
S
I D
IS
S
U E
D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
TE
C:\Users\vanderburb\Desktop\DoD Projects\DLA Tracy\CAD Files 100%\T-401 SITE
11/27/2019 12:10 PM
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
TI
O
N
J
U N
E
W
8-
-D
-0
100% DESIGN - 14 JUNE 2019
SCALE: 1" = 40'
SITE COMMUNICATIONS ENLARGEMENT PLAN 1 OF 3
M
AT
C H
LI
N
E
- S
EE
S
H
EE
T
SI
TE
T
-4
SI
TE
C O
M M
U N
IC
A
TI
O
N S
EN
LA
R G
ED
P
LA
N
O
F
T-401
SK BR AH KW
SITE
00 40' 80'
NEW UNDERGROUND COMM. CONDUIT
EXISTING UNDERGROUND COMM. CONDUIT
CABLE PATHWAY
COMM VAULT BOX
POLE
RISER POLE
C(UG)
C(UG)
LEGEND
GENERAL NOTES
1. THE NEW PATHWAYS SHOWN ARE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .