Amendment 5 Revised Drawings(updated 22Nov19).pdf

PDF 385 KB Posted

Attached to
W9123820B0001 - Tracy ACP Federal contract opportunity
Solicitation number
W91238-20-B-0001
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

This pre-solicitation notice is for upgrade of the main gate access control point at Defense Depot San Joaquin in Tracy, California. The Corps of Engineers will issue solicitation number W91238-20-B-0001 through FedBizOpps by the end of October 2019 for upgrading facilities including a gatehouse, visitor control center, vehicle inspection facility, guard booths and overwatch buildings. The estimated cost range is $15-25 million. The period of performance after notice to proceed is 540 days. The NAICS code is 236220 for construction of institutional buildings. The size standard is $36.5 million. Interested parties must register in the System for Award Management and FedBizOpps to access solicitation documents, which will be posted electronically only. All questions should be directed to the named contracting specialist.

View the file

Other files for this federal contract opportunity

Other files attached to W9123820B0001 - Tracy ACP, newest first.
File Type Posted
ABSTRACT OF BIDS.pdf PDF
Amendment 6.Asbuilt Drawings and Tech Data for padmount transformers Bldg 57.pdf PDF
Amendment 6.pdf PDF
Amendment 6 List of changes.pdf PDF
Amendment 6 TracyACP_Specifications-All (updated 29Nov19).pdf PDF
Amendment 6 Revised Drawings(updated 2 Dec 19).pdf PDF
Amendment 5 TracyACP_Specifications-All (updated 22Nov19).pdf PDF
Amendment 5.pdf PDF
Amendment 5 List of changes.pdf PDF
SF30_Amendment_0004_Extend_Bid_Opening.pdf PDF
WH-3_and_WH-1_Drawings_for_Amend_0004.pdf PDF
Appendix_K_SURVEY_RPT.pdf PDF
Summary_of_Changes_for_Amendment_0004.pdf PDF
Geotechnical_Report_for_ACP_Tracy_July2019.pdf PDF
SUBMITTAL_REGISTER.pdf PDF
SF30_Amendment_0003_Revise_Pre-Award_Survey.pdf PDF
Revise_Attachment_1_Section_25_05_11.01.pdf PDF
Revise_Attachment_1_Section_25_05_11.04.pdf PDF
Revise_Attachment_1_Section_25_05_11.03.pdf PDF
Atch_7_Bid_Schedule_DDJC_Tracy_Upgrade_ACP.pdf PDF
Revise_Attachment_1_Section_25_05_11.02.pdf PDF
SF30_Amendment_0002_Extend_and_Revise_Specs._10-24-19.pdf PDF
Amendment_0002_Summary_of_Changes_to_Attachment_1_--_Specifications.pdf PDF
Atch_6_Structural_Interior_Design.pdf PDF
20B0001_Am_1.docx DOCX document
20B0001_Am_1_Conformed_Copy.docx DOCX document
Furniture.Fixtures.Equipment_22Jul19.pdf PDF
DD1354_Transfer_of_Real_Property_01April19.pdf PDF
Site_Visit_Sign_In_Sheet.pdf PDF
Wage_Determination_26Jul19.pdf PDF
W9123820B0001_Official_Solicitation.docx DOCX document
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELEVATION C AND (A MIRRORED) ELEVATION D

ELEVATION B SIMILAR

FIN.

FLOOR

FIN.

CEILING

/2

FIELD INSTALLED MASONARY

VENEER FINISH

STANDING SEAM HIP ROOF

W/ EXTENDED OVERHANG

TINTED GLAZING

DURASTEEL WITH UL 752

LEVEL 3 BULLET RESISTANT

CONSTRUCTION

HVAC UNITHVAC UNIT

OPEN

/2

INFRARED RADIANT HEATER

NOTE : DOOR CLEAR

OPENING TO BE 32"

ROOF OVERHANG

C

A

D

HMD-SL-BR

HMD-SL-BR

B

HVAC

(HIGH)

10' - 0"

3' - 2"3' - 8"3' - 2"

3"x3" ANCHOR TAB W/

3/4" DIA. HOL (TYP. 4)

24" DEEP STAINLESS

STEEL WORK COUNTER

1. THE ENTIRE DESIGN OF THIS BUILDING SHALL BE

CONSIDERED "DELEGATED ENGINEERED SYSTEMS" AS

DEFINED IN SECTION 2-1.1.1 OF UFC 3-301-01. SEE PROJECT

SPECIFICATION FOR PREMANUFACTURED STRUCTURES.

2. THE CONTRACTOR SHALL SUBMIT A COMPLETE SET

OF SHOP DRAWINGS (INCLUSIVE OF MECHANICAL,

ELECTRICAL AND STRUCTURAL DESIGN DRAWINGS) TO

ARCHITECT/ENGINEER FOR REVIEW PRIOR TO THE BUILDING

FABRICATION. REVIEW OF SHOP DRAWINGS BY THE

ARCHITECT/ENGINEER IS FOR GENERAL COMPLIANCE WITH

THE CONTRACT DOCUMENTS ONLY. THE CONTRACTOR WILL

REMAIN RESPONSIBLE FOR ALL ERRORS OF DETAILING,

FABRICATION, AND FOR CORRECT FITTING OF ALL

COMPONENTS AND MEMBERS INCLUDING COORDINATION

WITH OTHERS TRADES. SHOP DRAWING SUBMITTALS

PROCESSED BY THE ENGINEER DO NOT CONSTITUTE CHANGE

ORDER. ANY PROPOSED CHANGES MUST BE SUBMITTED IN A

LETTER OR DETAIL TO THE ARCHITECT/ENGINEER FOR

APPROVAL. NOTE REFER TO NOTE NO. 7 BELOW FOR

ADDITIONAL MECHANICAL REQUIREMENTS.

3. ELECTRICAL, MECHANICAL, COMMUNICATIONS AND

SECURITY CONTROLS SYSTEMS SWITCHES WILL BE WALL

MOUNTED. PREMANUFACTURED STRUCTURES BUILDING

MANUFACTURER SHALL PROVIDE ELECTRICAL, MECHANICAL,

COMMUNICATIONS AND SECURITY CONTROLS SYSTEMS

INFRASTRUCTURE WITH IN-WALL CONDUIT PATHWAYS, AND

CONTRACTOR SHALL CONNECT AND ANCHOR SURFACE

MOUNTED CONTROLS SWITCHES AND PLATES AS REQUIRED

FOR CONTROLS EQUIPMENT CONNECTIVITY PER ELECTRICAL

AND MECHANICAL DRAWINGS AND SPECIFICATIONS FOR

PERFORMANCE REQUIREMENTS. TYPICAL MOUNTING HEIGHT

RANGE FOR CONTROLS IS BETWEEN 36" AND 48" ABOVE

FINISH FLOOR. SHOP DRAWINGS SHALL INCLUDE TYPE AND

SIZE OF IN-WALL CONDUIT PATHWAYS AND PROPOSED

TERMINIATIONS LOCATIONS.

4. ANCHORING WITH EXPANSION ANCHORS SHALL BE

DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17,

ASSUMING CRACKED CONCRETE CONDITIONS. EXPANSION

BOLTS TO BE OF DIAMETER, EMBEDMENT AND FINISH AS

INDICATED ON THE DRAWINGS AND SPECIFICATIONS. UNLESS

NOTED OTHERWISE, USE 1/2" DIA. CARBON STEEL BOLTS WITH

3.5" EFFECTIVE EMBEDMENT. LOAD VALUES FOR KB-TZ AS

MANUFACTURED BY HILTI HAVE BEEN USED AS THE BASIS OF

DESIGN. PROVIDE ANY APPROPRIATE EXPANISION ANCHOR

WITH EQUIVALENT SHEAR AND TENSION CAPACITIES AFTER

MODIFICATION DUE TO EMEBEMENT, SPACING AND EDGE

DISTANCES. LOAD CAPACITIES SHALL BE BASED ON TESTS IN

ACCORDANCE WITH ACI 355.2 AND ICC-ES AC 193. INSTALL

ANCHORS PER THE MANUFACTURER'S INSTRUCTIONS AND

RECOMMENDATIONS. OTHER AVAILABLE MANUFACTURERS

INCLUDE SIMPSON AND POWERS FASTENERS. CONCRETE IN

WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR

WEIGHT (145 PCF, MIN.) WITH A MINIMUM 28 DAY

COMPRESSIVE STRENGTH OF 4,000 PSI. ANCHOR DIAMETER

REFERS TO THE THREAD SIZE.

5. ANCHORING WITH ADHESIVE ANCHOR SIZES SHALL BE

BASED ON HILTI HIT HY-200, ADHESIVE ANCHOR SYSTEM WITH

HAS THREADED ROD. ANY SYSTEM CONSISTING OF AN

EQUIVALENT TWO-COMPONENT STRUCTURAL GRADE

INJECTION MATERIAL CONFORMING TO ASTM C881 THAT

MEETS OR EXCEEDS THE CAPACITIES OF THE HILTI SYSTEM

AND IS APPROVED BY THE STRUCTUAL ENGINEER MAY BE

USED. ANCHOR SYSTEM MUST BE SHOWN TO HAVE

APPROVAL FROM THE ICC WITH A DOCUMENTED ICC

EVALUATION SERVICES REPORT. EXPOXY ANCHORS SHALL BE

DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17

ASSUMING CRACKED CONCRETE CONDITIONS. CONCRETE IN

WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR

WEIGHT (145 PCF MIN) WITH A MINIMUM 28 DAY COMPRESSIVE

STRENGTH OF 4,000 PSI. TESTING OF CORE SAMPLES TO BE

PERFORMED BY THE CONTRACTOR AS NEEDED TO

DEMONSTRATE EXISTING CONCRETE STRENGTH, OR

CONSTRACTOR TO OBTAIN RECORDS OF ORIGINAL TEST

SAMPLES. ALL EPOXY ANCHOR INSTALLATIONS SHALL

COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS

AND SPECIFICATIONS. DUST SHALL BE BLOWN FROM THE

HOLE WITH COMPRESSED AIR TO ENSURE PROPER ANCHOR

SEATING DEPTH AND TO PROVIDE A CLEAN BONDING

SURFACE. ADDITIONALLY, THE HOLE SHALL BE BRUSHED WITH

A NYLON BRUSH THEN BLOWN AGAIN WITH COMPRESSED AIR.

EPOXY SHALL ONLY BE APPLIED TO CLEAN DRY SURFACES.

BASE MATERIAL TEMPERATURE MUST NOT BE BELOW 40 F.

6. THE BUILDING WILL ARRIVE ON-SITE AS A FULLY

ASSEMBLED PREMANUFACTURED STRUCTURE, AND THE

CONTRACTOR IS REPSONSIBLE TO PROVIDE A CRANE OR LIFT

SYSTEM PER MANUFACTURER'S REQUIREMENTS TO PLACE

THE BUILDING IN THE DESIGNED LOCATION ONTO A

CONCRETE PAD WHERE IT WILL BE PREMANANTLY

ANCHORED; SEE CIVIL DRAWINGS FOR LOCATION

7. PROVIDE COMPLETE THRU-WALL HEATING,

VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEM TO

MAINTAIN CONDITIONS INDOORS AT 78F DRY BULB/50%

RELATIVE HUMIDITY MAXIMUM IN THE SUMMER AND 68 F DRY

BULB/30% RELATIVE HUMIDITY MINIMUM IN THE WINTER.

OUTDOOR CONDITIONS ARE 97.9 F DRY BULB/68.8 F WET BULB

IN THE SUMMER AND 32.7 F DRY BULB IN THE WINTER.

PROVIDE ASHRAE 62.1-2010 OUTDOOR AIR (VENTILATION) TO

THE SPACE THROUGH THE HVAC UNIT. HVAC COIL CAPACITY

CALCULATIONS SHALL INCLUDE HEAT LOSSES DUE TO

VENTILATION AIR, OCCUPANTS, OFFICE EQUIPMENT,

LIGHTING, ENVELOPE INSULATION VALUE, ETC. PROVIDE

SEISMIC BRACING ON EQUIPMENT, DUCTWORK, PIPING, ETC.

AS REQUIRED. ALSO PROVIDE ELECTRIC INFRARED RADIANT

HEATER ON EXTERIOR OF GUARD BOOTH, MOUNTED

DIRECTLY OVER EXIT DOORWAY AT A 45-DEGREE ANGLE WITH

MANUAL OCCUPANT ON/OFF DIAL AND TIMER INSIDE THE

GUARD BOOTH, ADJACENT TO DOOR. UNIT CAPACITY SHALL

BE 1,500 WATTS (5,118 BTU) AND RATED FOR OUTDOOR USE.

INSTALL ALL HVAC EQUIPMENT PER MANUFACTURER

RECOMMENDATIONS. SEE MECHANICAL-SERIES DRAWING

SHEET M-001 FOR VISITOR CONTROL CENTER AND DIVISION

22/23 SPECIFICATIONS FOR GENERAL NOTES REGARDING THE

HVAC PROJECT SCOPE AND REQUIREMENTS.

8. FINISH AND COLOR SELECTIONS FOR INTERIOR AND

EXTERIOR SURFACES, INCLUSIVE OF ROOFING, WALL PANELS,

DOORS, WINDOWS, INTERIOR WALL PANELS, CASEWORK,

COUNTERS, AND OTHER ELEMENTS THAT WILL BE VISIBLE TO

THE PUBLIC, WILL BE CHOSEN AS PART OF THE SHOP

DRAWING REVIEW PROCESS, AND WILL BE SELECTED FROM

THE BUILDINGS MFG'S. STANDARD COLOR SELECTIONS,

UNLESS OTHERWISE DIRECTED ON THE DRAWINGS.

UL 752 LEVEL 3 BULLET RESISTANT CONSTRUCTION, SLIDING DOOR, TINTED GLAZING, FACTORY ADHERED BRICK FINISH, THRU WALL HAVC, EXTERIOR LIGHTING AND STANDING SEAM HIP ROOF WITH EXTENDED OVERHANG

1. ROOF INCLUDES A FULLY INSTALLED STANDING SEAM METAL ROOF.

2. A CONTINUOUS SHEET OF HARDENED BALLISTIC RATED STEEL IS USED FOR EACH WALL TO CREATE A SEAMLESS BALLISTIC BARRIER FROM GRADE TO THE ROOF LINE.

3. BULLET RESISTANT STEEL TOP-SUSPENDED SLIDING DOOR.

4. DURABLE STEEL CONSTRUCTION CONSISTING OF STRUCTURAL ASTM A500 GRADE B WELDED STEEL EXTERIOR WALL PANELS AND 16 GUAGE INTERIOR WALL PANELS.

5. FULLY INSULATED WALLS AND CEILING.

6. WINDOWS ARE CLEAR OR TINTED GLAZING AND SLIDING TYPE.

7. 1 1/2" SOLID INSULATING FLOOR STRUCTURE WITH MAINTENANCE-FREE ALUMINUM TREADPLATE FINSIHED SURFACE.

8. ALL STEEL SURFACES ARE ELECTROSTATICALLY PAINTED WITH RUST INHIBITIVE EPOXY PRIMER AND HAVE A FINISHED COAT OF AN AIR DRY INDUSTRIAL ARCYLIC PAINT.

9. EXTERIOR FACADE FINISH COLORS TO MATCH BUILDING 128 IN ALL RESPECTS.

GUARD BOOTH DESIGN CRITERIA

DEGREES F

WET BULB

51.5

DEGREES F

WET BULB

% RELATIVE

HUMIDITY

% RELATIVE

HUMIDITY

SUMMER 78.0

DEGREES F

DRY BULB

WINTER 68.0

DEGREES F

DRY BULB

NOTES: 1. SETPOINT DATA BASED ON UFC 3-410-01 REQUIREMENTS.

INDOOR DESIGN CONDITIONS

68.8

DEGREES F

WET BULB

SUMMER 97.9

DEGREES F

DRY BULB

WINTER 32.7 DEGREES F

NOTES: 1. WEATHER DATA BASED ON ASHRAE CLIMACTIC DATA,

UFC 3-400-02, AND UFC 3-410-01 REQUIREMENTS.

OUTDOOR DESIGN CONDITIONS

COLOR FINISH NOTES:

1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)

2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.

3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.

4. DOORS AND FRAMES TO MATCH ROOFING COLOR.

5. WINDOW FRAMES TO MATCH ROOFING COLOR.

6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

L

S T

R E

E T

S

T E

S A

C R

A M

E N

T O

C

A

P

-4

-5

F

-4

-5

SHEET NOTES

BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_GUARD_BOOTH.rvt

11/21/2019 3:54:48 PM

262207

A-501

BLDG 130

A, B, & C

P L

A N

V

IE

W

E L

E V

A T

IO

N

D L

A D

IS

T

R

IB

U T

IO

N

S A

N J

O A

Q U

IN

C

A S

A C

R A

M E

N T

O D

IS

T

R

IC

T

S A

C R

A M

E N

T O

C

A L

IF

O

R N

IA

-2

J

U L Y

W -1

-D

-0

RTA DESIGN - 22 JULY 2019

U P

G R

A D

E M

A

IN

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P

D D

C X

B L

D G

A

B

C

G

U A

R D

B O

O T

H

A C

S G

/s A

H

1/2" = 1'-0"A-501

ELEVATIONS2

1/2" = 1'-0"A-501

PLAN VIEW1

0 1' 2' 4'

INTERNATIONAL BUILDING CODE ANALYSIS:

CONSTRUCTION TYPE:

A. TYPE V-NS

B. NON-RATED

C. UNPROTECTED STRUCTURE

D. NON-SPRINKLER

OCCUPANCY TYPE: "B"

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/1 /1

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/2 /1

** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE

MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.

WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE

MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE

PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE

SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED

PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR

SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY

VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER

AND THE METAL PANELS ABOVE.

FINISH CEILING

8' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.W.

9' - 2"

T.O.S.

0' - 0"

SEE 5/A-201 FOR GUTTER DETAILS

FINISH CEILING

8' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.W.

9' - 2"

T.O.S.

0' - 0"

AB

FINISH CEILING

8' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.W.

9' - 2"

T.O.S.

0' - 0"

1 2

FOUNDATION PADALL DOORS TO BE BALLISTIC

RATED & MIN 3070, TYP.

FIELD INSTALLED MASONRY VENEER TO

MATCH VCC COLOR SELECTION.

INSTALLED BY GENERAL CONTRACTOR

STANDING SEAM METAL

ROOF FULLY INSULATED

TYP BALLISTIC RATED

WINDOW. MIN 3040 ALL

WINDOWS

BALLISTIC RATED MTL

WALL PANELS

T

O C

L

12" TO CL

24" TO CL

#12 BUILDING SIGN CENTERED ON

FINISH CEILING. SEE 12/AI-501

ROOM SIGN TYP. SEE #11/AI-

501 FURNISHED & INSTALLED

BY GENERAL CONTRACTOR

SEE 5/A-201 FOR GUTTER DETAILS

T

O C

L

EQEQ

ROOM SIGN TYP. SEE #10/AI-

501 FURNISHED & INSTALLED

BY GENERAL CONTRACTOR

ROOM SIGN TYP. SEE #6/AI-

501 FURNISHED & INSTALLED

BY GENERAL CONTRACTOR

12" TO CL

FINISH CEILING

8' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.W.

9' - 2"

T.O.S.

0' - 0"

A B

24" TO CL

#12 BUILDING SIGN CENTERED ON

FINISH CEILING. SEE 12/AI-501

COLOR FINISH NOTES:

1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)

2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.

3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.

4. DOORS AND FRAMES TO MATCH ROOFING COLOR.

5. WINDOW FRAMES TO MATCH ROOFING COLOR.

6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.

HEAVY DUTY SUPPORT BRACKETS

@ 30" CENTERS. (OPTIONAL)

HEAVY DUTY INTERIOR STRAPS

@ 30" CENTER.

GUTTER PROFILE 10' LENGTH, 1"

TELESCOPING JOINTS.

#10 X 2" S.S. WOOD SCREWS

1-1/2" STAINLESS NAILS OR #10

X 1 1/2" S.S. WOOD SCREWS.

ALUMINUM RIVET TO SECURE

INTERIOR STRAP OT GUTTER.

0' - 5"

0' - 4"

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

L

S T

R E

E T

S

T E

S A

C R

A M

E N

T O

C

A

P

-4

-5

F

-4

-5

BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_INSPECTION_FACILITY.rvt

11/21/2019 3:56:50 PM

261217

A-201

BLDG 131

E X

T E

R

IO

R E

L E

V A

T

IO

N S

D L

A D

IS

T

R

IB

U T

IO

N

S A

N J

O A

Q U

IN

C

A S

A C

R A

M E

N T

O D

IS

T

R

IC

T

S A

C R

A M

E N

T O

C

A L

IF

O

R N

IA

-2

J

U N

E

W -1

-D

-0

100% DESIGN - 14 JUNE 2019

U P

G R

A D

E M

A

IN

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P

D D

C X

B L

D G

I N

S P

E C

T

IO

N B

U

IL

D

IN

G

B

ID

O P

T

IO

N

J V

S M

S G

A H

3/8" = 1'-0"1

WEST ELEVATION

3/8" = 1'-0"2

NORTH ELEVATION

3/8" = 1'-0"3

EAST ELEVATION

3/8" = 1'-0"4

SOUTH ELEVATION

3" = 1'-0"5

INDUSTRIAL SERIES COMMERCIAL

GUTTER SYSTEM G1-R6

** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE

MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.

WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE

MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE

PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE

SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED

PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR

SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY

VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER

AND THE METAL PANELS ABOVE.

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/2 /1

T.O.W.

9' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.S.

0' - 0"

FINISH CEILING

8' - 2"

FOUNDATION PADFIELD INSTALLED MASONRY

VENEER TO MATCH VCC

COLOR SELECTION

STANDING SEAM METAL

ROOF FULLY INSULATED

TYP BALLISTIC RATED WINDOW.

MIN 3040 ALL WINDOWS

BALLISTIC RATED MTL

WALL PANELS

ALL DOORS TO BE BALLISTIC

RATED & MIN 3070, TYP.

SEE 5/A-201 FOR GUTTER PROFILE

#12 BUILDING SIGN CENTERED ON

FINISH CEILING. SEE 12/AI-501

ROOM SIGN TYP. SEE #11/AI-

501 FURNISHED & INSTALLED

BY GENERAL CONTRACTOR

T

O C

L

48" TP CL

12" TO CL

T

O C

L

ROOM SIGN TYP. SEE #10/AI-

501 FURNISHED & INSTALLED

BY GENERAL CONTRACTOR

EQEQ

ROOM SIGN TYP. SEE #6/AI-

501 FURNISHED & INSTALLED

BY GENERAL CONTRACTOR

AB

T.O.W.

9' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.S.

0' - 0"

FINISH CEILING

8' - 2"

A B

T.O.W.

9' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.S.

0' - 0"

FINISH CEILING

8' - 2"

2 1

T.O.W.

9' - 2"

FINISH FLOOR

LINE

0' - 2"

T.O.S.

0' - 0"

FINISH CEILING

8' - 2"

SEE 5/A-201 FOR GUTTER DETAIL

12" TO CL

T

O C

L

COLOR FINISH NOTES:

1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)

2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.

3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.

4. DOORS AND FRAMES TO MATCH ROOFING COLOR.

5. WINDOW FRAMES TO MATCH ROOFING COLOR.

6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.

HEAVY DUTY SUPPORT BRACKETS

@ 30" CENTERS. (OPTIONAL)

HEAVY DUTY INTERIOR STRAPS

@ 30" CENTER.

GUTTER PROFILE 10' LENGTH, 1"

TELESCOPING JOINTS.

#10 X 2" S.S. WOOD SCREWS

1-1/2" STAINLESS NAILS OR #10

X 1 1/2" S.S. WOOD SCREWS.

ALUMINUM RIVET TO SECURE

INTERIOR STRAP OT GUTTER.

0' - 5"

0' - 4"

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

L

S T

R E

E T

S

T E

S A

C R

A M

E N

T O

C

A

P

-4

-5

F

-4

-5

BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_GATEHOUSE.rvt

11/21/2019 3:58:36 PM

261240

A-201

BLDG 133

E X

T E

R

IO

R E

L E

V A

T

IO

N S

D L

A D

IS

T

R

IB

U T

IO

N

S A

N J

O A

Q U

IN

C

A S

A C

R A

M E

N T

O D

IS

T

R

IC

T

S A

C R

A M

E N

T O

C

A

-2

J

U N

E

W -1

-D

100% DESIGN - 14 JUNE 2019

U P

G R

A D

E M

A

IN

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P

D D

C X

B L

D G

G A

T E

H O

U S

E

J V

S M

S G

A H

3/8" = 1'-0"2

EAST ELEVATION

3/8" = 1'-0"1

NORTH ELEVATION

3/8" = 1'-0"3

SOUTH ELEVATION

3/8" = 1'-0"4

WEST ELEVATION

3" = 1'-0"5

INDUSTRIAL SERIES COMMERCIAL

GUTTER SYSTEM G1-R6

** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE

MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.

WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE

MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE

PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE

SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED

PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR

SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY

VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER

AND THE METAL PANELS ABOVE.

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/2 /1

22"

3"x3" ANCHOR TAB W/

3/4"DIA. HOLE (TYP. 4)

ROOF OVERHANG

C

A

D

HMD-SL-BR

B

HVAC

(HIGH)

HMD-SL-BR

6' - 0"

32" CLR OPNG

32" CLR OPNG

ELEVATION A AND (C MIRRORED) ELEVATION D (B MIRRORED W/O HVAC UNIT)

FIN.

FLOOR

FIN.

CEILING

/2

STANDING SEAM HIP ROOF

W/ EXTENDED OVERHANG.

DURASTEEL WITH UL 752

LEVEL 3 BULLET RESISTANT

CONSTRUCTION.

FIELD APPLIED MASONRY

VEENER FINISH

TINTED GLAZING

HVAC UNIT

SLIDING DOOR W/ MIN

32" CLR OPENING WHEN

DOOR IS OPEN

1. THE ENTIRE DESIGN OF THIS BUILDING SHALL BE

CONSIDERED "DELEGATED ENGINEERED SYSTEMS" AS

DEFINED IN SECTION 2-1.1.1 OF UFC 3-301-01. SEE PROJECT

SPECIFICATION FOR PREMANUFACTURED STRUCTURES.

2. THE CONTRACTOR SHALL SUBMIT A COMPLETE SET

OF SHOP DRAWINGS (INCLUSIVE OF MECHANICAL,

ELECTRICAL AND STRUCTURAL DESIGN DRAWINGS) TO

ARCHITECT/ENGINEER FOR REVIEW PRIOR TO THE BUILDING

FABRICATION. REVIEW OF SHOP DRAWINGS BY THE

ARCHITECT/ENGINEER IS FOR GENERAL COMPLIANCE WITH

THE CONTRACT DOCUMENTS ONLY. THE CONTRACTOR WILL

REMAIN RESPONSIBLE FOR ALL ERRORS OF DETAILING,

FABRICATION, AND FOR CORRECT FITTING OF ALL

COMPONENTS AND MEMBERS INCLUDING COORDINATION

WITH OTHERS TRADES. SHOP DRAWING SUBMITTALS

PROCESSED BY THE ENGINEER DO NOT CONSTITUTE CHANGE

ORDER. ANY PROPOSED CHANGES MUST BE SUBMITTED IN A

LETTER OR DETAIL TO THE ARCHITECT/ENGINEER FOR

APPROVAL. NOTE REFER TO NOTE NO. 7 BELOW FOR

ADDITIONAL MECHANICAL REQUIREMENTS.

3. ELECTRICAL, MECHANICAL, COMMUNICATIONS AND

SECURITY CONTROLS SYSTEMS SWITCHES WILL BE WALL

MOUNTED. PREMANUFACTURED STRUCTURES BUILDING

MANUFACTURER SHALL PROVIDE ELECTRICAL, MECHANICAL,

COMMUNICATIONS AND SECURITY CONTROLS SYSTEMS

INFRASTRUCTURE WITH IN-WALL CONDUIT PATHWAYS, AND

CONTRACTOR SHALL CONNECT AND ANCHOR SURFACE

MOUNTED CONTROLS SWITCHES AND PLATES AS REQUIRED

FOR CONTROLS EQUIPMENT CONNECTIVITY PER ELECTRICAL

AND MECHANICAL DRAWINGS AND SPECIFICATIONS FOR

PERFORMANCE REQUIREMENTS. TYPICAL MOUNTING HEIGHT

RANGE FOR CONTROLS IS BETWEEN 36" AND 48" ABOVE

FINISH FLOOR. SHOP DRAWINGS SHALL INCLUDE TYPE AND

SIZE OF IN-WALL CONDUIT PATHWAYS AND PROPOSED

TERMINIATIONS LOCATIONS.

4. ANCHORING WITH EXPANSION ANCHORS SHALL BE

DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17,

ASSUMING CRACKED CONCRETE CONDITIONS. EXPANSION

BOLTS TO BE OF DIAMETER, EMBEDMENT AND FINISH AS

INDICATED ON THE DRAWINGS AND SPECIFICATIONS. UNLESS

NOTED OTHERWISE, USE 1/2" DIA. CARBON STEEL BOLTS WITH

3.5" EFFECTIVE EMBEDMENT. LOAD VALUES FOR KB-TZ AS

MANUFACTURED BY HILTI HAVE BEEN USED AS THE BASIS OF

DESIGN. PROVIDE ANY APPROPRIATE EXPANISION ANCHOR

WITH EQUIVALENT SHEAR AND TENSION CAPACITIES AFTER

MODIFICATION DUE TO EMEBEMENT, SPACING AND EDGE

DISTANCES. LOAD CAPACITIES SHALL BE BASED ON TESTS IN

ACCORDANCE WITH ACI 355.2 AND ICC-ES AC 193. INSTALL

ANCHORS PER THE MANUFACTURER'S INSTRUCTIONS AND

RECOMMENDATIONS. OTHER AVAILABLE MANUFACTURERS

INCLUDE SIMPSON AND POWERS FASTENERS. CONCRETE IN

WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR

WEIGHT (145 PCF, MIN.) WITH A MINIMUM 28 DAY

COMPRESSIVE STRENGTH OF 4,000 PSI. ANCHOR DIAMETER

REFERS TO THE THREAD SIZE.

5. ANCHORING WITH ADHESIVE ANCHOR SIZES SHALL BE

BASED ON HILTI HIT HY-200, ADHESIVE ANCHOR SYSTEM WITH

HAS THREADED ROD. ANY SYSTEM CONSISTING OF AN

EQUIVALENT TWO-COMPONENT STRUCTURAL GRADE

INJECTION MATERIAL CONFORMING TO ASTM C881 THAT

MEETS OR EXCEEDS THE CAPACITIES OF THE HILTI SYSTEM

AND IS APPROVED BY THE STRUCTUAL ENGINEER MAY BE

USED. ANCHOR SYSTEM MUST BE SHOWN TO HAVE

APPROVAL FROM THE ICC WITH A DOCUMENTED ICC

EVALUATION SERVICES REPORT. EXPOXY ANCHORS SHALL BE

DESIGNED AND IN ACCORDANCE WITH ACI-318 CHAPTER 17

ASSUMING CRACKED CONCRETE CONDITIONS. CONCRETE IN

WHICH ANCHORS ARE INSTALLED SHALL BE REGULAR

WEIGHT (145 PCF MIN) WITH A MINIMUM 28 DAY COMPRESSIVE

STRENGTH OF 4,000 PSI. TESTING OF CORE SAMPLES TO BE

PERFORMED BY THE CONTRACTOR AS NEEDED TO

DEMONSTRATE EXISTING CONCRETE STRENGTH, OR

CONSTRACTOR TO OBTAIN RECORDS OF ORIGINAL TEST

SAMPLES. ALL EPOXY ANCHOR INSTALLATIONS SHALL

COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS

AND SPECIFICATIONS. DUST SHALL BE BLOWN FROM THE

HOLE WITH COMPRESSED AIR TO ENSURE PROPER ANCHOR

SEATING DEPTH AND TO PROVIDE A CLEAN BONDING

SURFACE. ADDITIONALLY, THE HOLE SHALL BE BRUSHED WITH

A NYLON BRUSH THEN BLOWN AGAIN WITH COMPRESSED AIR.

EPOXY SHALL ONLY BE APPLIED TO CLEAN DRY SURFACES.

BASE MATERIAL TEMPERATURE MUST NOT BE BELOW 40 F.

6. THE BUILDING WILL ARRIVE ON-SITE AS A FULLY

ASSEMBLED PREMANUFACTURED STRUCTURE, AND THE

CONTRACTOR IS REPSONSIBLE TO PROVIDE A CRANE OR LIFT

SYSTEM PER MANUFACTURER'S REQUIREMENTS TO PLACE

THE BUILDING IN THE DESIGNED LOCATION ONTO A

CONCRETE PAD WHERE IT WILL BE PREMANANTLY

ANCHORED; SEE CIVIL DRAWINGS FOR LOCATION.

7. PROVIDE COMPLETE THRU-WALL HEATING,

VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEM TO

MAINTAIN CONDITIONS INDOORS AT 78F DRY BULB/50%

RELATIVE HUMIDITY MAXIMUM IN THE SUMMER AND 68 F DRY

BULB/30% RELATIVE HUMIDITY MINIMUM IN THE WINTER.

OUTDOOR CONDITIONS ARE 97.9 F DRY BULB/68.8 F WET BULB

IN THE SUMMER AND 32.7 F DRY BULB IN THE WINTER.

PROVIDE ASHRAE 62.1-2010 OUTDOOR AIR (VENTILATION) TO

THE SPACE THROUGH THE HVAC UNIT. HVAC COIL CAPACITY

CALCULATIONS SHALL INCLUDE HEAT LOSSES DUE TO

VENTILATION AIR, OCCUPANTS, OFFICE EQUIPMENT,

LIGHTING, ENVELOPE INSULATION VALUE, ETC. PROVIDE

SEISMIC BRACING ON EQUIPMENT, DUCTWORK, PIPING, ETC.

AS REQUIRED. SEE MECHANICAL-SERIES DRAWING SHEET

M-001 FOR VISITOR CONTROL CENTER AND DIVISION 22/23

SPECIFICATIONS FOR GENERAL NOTES REGARDING THE HVAC

PROJECT SCOPE AND REQUIREMENTS.

8. FINISH AND COLOR SELECTIONS FOR INTERIOR AND

EXTERIOR SURFACES, INCLUSIVE OF ROOFING, WALL PANELS,

DOORS, WINDOWS, INTERIOR WALL PANELS, CASEWORK,

COUNTERS, AND OTHER ELEMENTS THAT WILL BE VISIBLE TO

THE PUBLIC, WILL BE CHOSEN AS PART OF THE SHOP

DRAWING REVIEW PROCESS, AND WILL BE SELECTED FROM

THE BUILDINGS MFG'S. STANDARD COLOR SELECTIONS,

UNLESS OTHERWISE DIRECTED ON THE DRAWINGS.

UL 752 LEVEL 3 BULLET RESISTANT CONSTRUCTION, SLIDING DOOR, TINTED GLAZING, FACTORY ADHERED BRICK FINISH, THRU WALL HAVC, EXTERIOR LIGHTING AND STANDING SEAM HIP ROOF WITH EXTENDED OVERHANG

1. ROOF: INSULATED STANDING SEAM METAL ROOF.

2. A CONTINUOUS SHEET OF HARDENED BALLISTIC RATED STEEL IS USED FOR EACH WALL TO CREATE A SEAMLESS BALLISTIC BARRIER FROM GRADE TO THE ROOF LINE.

3. BULLET RESISTANT STEEL SWING DOOR.

4. DURABLE STEEL CONSTRUCTION CONSISTING OF STRUCTURAL ASTM A500 GRADE B WELDED STEEL EXTERIOR WALL PANELS AND 16 GUAGE INTERIOR WALL PANELS.

5. FULLY INSULATED WALLS AND CEILING.

6. WINDOWS ARE CLEAR OR TINTED GLAZING AND SLIDING TYPE.

7. 1 1/2" SOLID INSULATING FLOOR STRUCTURE WITH MAINTENANCE-FREE ALUMINUM TREADPLATE FINSIHED SURFACE.

8. ALL STEEL SURFACES ARE ELECTROSTATICALLY PAINTED WITH RUST INHIBITIVE EPOXY PRIMER AND HAVE A FINISHED COAT OF AN AIR DRY INDUSTRIAL ARCYLIC PAINT.

9. EXTERIOR FACADE FINISH COLORS TO MATCH BUILDING 128 IN ALL RESPECTS.

10. GUN PORTS SHALL BE PROVEDED ON EACH FACE OF THE OVERWATCH.

11. ALL GUN PORTS SHALL BE USABLE FOR BOTH HANDGUN AND SHOULDER FIRED WEAPONS. GUNPORT DESIGN SHALL NOT REQUIRE WEAPONS TO BE ORIENTED IN AN UNUSUAL WAY (EG. GUNPORT BEING PLACED IMMEDIATELY ABOVE COUNTER AND COUNTER INTERFERING WITH VERTICAL ORIENTATiON OF PISTOL MAGAZINE.)

OVERWATCH DESIGN CRITERIA

DEGREES F

WET BULB

51.5

DEGREES F

WET BULB

% RELATIVE

HUMIDITY

% RELATIVE

HUMIDITY

SUMMER 78.0

DEGREES F

DRY BULB

WINTER 68.0

DEGREES F

DRY BULB

NOTES: 1. SETPOINT DATA BASED ON UFC 3-410-01 REQUIREMENTS.

INDOOR DESIGN CONDITIONS

68.8

DEGREES F

WET BULB

SUMMER 97.9

DEGREES F

DRY BULB

WINTER 32.7 DEGREES F

NOTES: 1. WEATHER DATA BASED ON ASHRAE CLIMACTIC DATA,

UFC 3-400-02, AND UFC 3-410-01 REQUIREMENTS.

OUTDOOR DESIGN CONDITIONS

COLOR FINISH NOTES:

1. VENEER TO MATCH VCC COLOR SELECTION OF SPLIT FACE CMU. (SEE ** BELOW)

2. UPPER FIELD TO MATCH VCC BURNISHED BLOCK COLOR SELECTION.

3. ROOFING TO MATCH VCC ROOFING AND COLOR SELECTION BY GOV.

4. DOORS AND FRAMES TO MATCH ROOFING COLOR.

5. WINDOW FRAMES TO MATCH ROOFING COLOR.

6. GLAZING TO BE BALLISTIC RATED/TINTED GLASS PER VCC SELECTION.

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

L

S T

R E

E T

S

T E

S A

C R

A M

E N

T O

C

A

P

-4

-5

F

-4

-5

SHEET NOTES

BIM 360://60587539-R19-Upgrade ACP DLA Tracy/A_TRACY_OVERWATCH.rvt

11/21/2019 4:00:01 PM

261254

A-501

BLDG 134

P R

E F

A B

R

IC

A T

E D

O V

E R

W A

T C

H

D L

A D

IS

T

R

IB

U T

IO

N

S A

N J

O A

Q U

IN

C

A S

A C

R A

M E

N T

O D

IS

T

R

IC

T

S A

C R

A M

E N

T O

C

A L

IF

O

R N

IA

-2

J

U N

E

W -1

-D

-0

100% DESIGN - 14 JUNE 2019

U P

G R

A D

E M

A

IN

A C

C E

S S

C O

N T

R O

L P

O

IN

T

P

D D

C X

B L

D G

O V

E R

W A

T C

H B

U

IL

D

IN

G

A C

S M

S G

A H

1/2" = 1'-0"A-501

OVERWATCH PLAN VIEW1

1/2" = 1'-0"A-501

OVERWATCH ELEVATIONS2

0 1' 2' 4'

NOTE: OVERWATCH DOOR REQUIREMENTS.

PROVIDE A MINIMUM 32" CLEAR OPENING (CLEAR WHEN DOOR IS FULLY

OPEN). PROVIDE A MIN 6'-8' HIGH SLIDING DOOR AS SHOWN. THAT WHEN

FULLY RETRACTED WILL PROVIDE THE REQUIRED 32" CLEAR OPENING.

THE DOOR SHALL BE DESIGNED SUCH THAT WHEN FULLY CLOSED, THE

DOOR SHALL OVERLAP THE BACK JAMB A MIN OF 1.5" AS TO NOT ALLOW

OBJECTS TO FREELY PASS BETWEEN THE JAMB AND FRAME.

OVERWATCH BUILDING IS CURRENTLY DESIGNED AT 6'-0" x 6'-0" FOR A

GROSS TOTAL OF 36 SF. PRE 10 UFC 2853, THE BUILDING AREA MAY BE

INCREASED BY 10 PERCENT TO A MAXIMUM OF 39.5 SF (AND OR

EXTENDED A DISTANCE OF 4.92") TO ALLOW FOR MEETING THE MINMUM

DOOR CLEARANCES.

INTERNATION BUILDING CODE ANALYSIS:

CONSTRUCTION TYPE:

A. TYPE V-NS

B. NON-RATED

C. UNPROTECTED STRUCTURE

D. NON-SPRINKLER

OCCUPANCY TYPE: "B" 2

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/1 /1

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/1 /1

R

E V

IS

IO

N S

P E

R I

N Q

U

IR

Y I

D

/2 /1

** THE MASONRY VENEER SHALL HAVE SPLIT FACE FINISH, SUCH AS THE SPLIT FACE

MASONRY UNITES UTILIZED FOR THE WAINSCOT OF VCC BUILDING. BUILDING NO. 128.

WITH A DIMENSIONAL SHAPE OF 8"x16"x1" MINIMUM, TO 3" MAX THICKNESS. THE

MASONRY VENEER SHALL BE APPLIED TO THE LOWER WAINSCOT LEVEL OF THE

PREFABRICATED BUILDINGS AND BOOTHS. THE CONTRACTOR AS PART OF THE

SUBMITTAL AND SHOP DRAWING PROCESS, WILL COORDINATE WITH THE SELECTED

PREFABRICATED BUILDING MANUFACTURER, AND THE MASONRY SUPPLIER, AND OR

SUB-CONTRACTOR TO COORDINATE THE EXTERIOR SUBSTRATE THE MASONRY

VENEERS WILL BE APPLIED TO AS WELL AS ANY FLASHING BETWEEN THE VENEER

AND THE METAL PANELS ABOVE.

Tracy DLA Bldg 130_Sht-A-501_Inquiry ID 8278523 Resp 11212019
Sheets
A-501 - PLAN VIEW / ELEVATION
Tracy DLA Bldg 131_Sht-A-201_Inquiry ID 8278523 Resp 11212019
Sheets
A-201 - EXTERIOR ELEVATIONS
Tracy DLA Bldg 133_Sht-A-201_Inquiry ID 8278523 Resp 11212019
Sheets
A-201 - EXTERIOR ELEVATIONS
Tracy DLA Bldg 134_Sht-A-501_Inquiry 8278523 Resp 11212019
Sheets
A-501 - PREFABRICATED OVERWATCH

File details come from the government source that posted it. Updated .