Amendment 5 List of changes.pdf

PDF 65 KB Posted

Attached to
W9123820B0001 - Tracy ACP Federal contract opportunity
Solicitation number
W91238-20-B-0001
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

This document provides details regarding Amendment 5 to the solicitation for the Tracy Access Control Point Upgrade project. The amendment includes revisions to specifications and drawings related to masonry veneer, concrete masonry units, and life safety plans. The federal contract opportunity involves upgrading facilities at the main gate and access control point for Defense Depot San Joaquin in Tracy, California. Services required include construction of a gatehouse, visitor control center, vehicle inspection facility with under-vehicle inspection, guard booths, and overwatch buildings. These facilities must incorporate fire suppression and alarm systems, mass notification, HVAC, electrical, building automation, energy monitoring and control systems, and utilities. The estimated cost range for the project is $15-25 million and the period of performance after notice to proceed is 540 days. The solicitation number is W91238-20-B-0001 and will be issued on FedBizOpps by the end of October 2019. The Army Corps of Engineers Engineering District Sacramento is the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to W9123820B0001 - Tracy ACP, newest first.
File Type Posted
ABSTRACT OF BIDS.pdf PDF
Amendment 6 TracyACP_Specifications-All (updated 29Nov19).pdf PDF
Amendment 6 Revised Drawings(updated 2 Dec 19).pdf PDF
Amendment 6.Asbuilt Drawings and Tech Data for padmount transformers Bldg 57.pdf PDF
Amendment 6.pdf PDF
Amendment 6 List of changes.pdf PDF
Amendment 5 Revised Drawings(updated 22Nov19).pdf PDF
Amendment 5 TracyACP_Specifications-All (updated 22Nov19).pdf PDF
Amendment 5.pdf PDF
Geotechnical_Report_for_ACP_Tracy_July2019.pdf PDF
Summary_of_Changes_for_Amendment_0004.pdf PDF
SF30_Amendment_0004_Extend_Bid_Opening.pdf PDF
WH-3_and_WH-1_Drawings_for_Amend_0004.pdf PDF
Appendix_K_SURVEY_RPT.pdf PDF
SUBMITTAL_REGISTER.pdf PDF
SF30_Amendment_0003_Revise_Pre-Award_Survey.pdf PDF
Revise_Attachment_1_Section_25_05_11.01.pdf PDF
Revise_Attachment_1_Section_25_05_11.04.pdf PDF
Revise_Attachment_1_Section_25_05_11.03.pdf PDF
SF30_Amendment_0002_Extend_and_Revise_Specs._10-24-19.pdf PDF
Amendment_0002_Summary_of_Changes_to_Attachment_1_--_Specifications.pdf PDF
Atch_7_Bid_Schedule_DDJC_Tracy_Upgrade_ACP.pdf PDF
Revise_Attachment_1_Section_25_05_11.02.pdf PDF
Atch_6_Structural_Interior_Design.pdf PDF
20B0001_Am_1.docx DOCX document
Furniture.Fixtures.Equipment_22Jul19.pdf PDF
DD1354_Transfer_of_Real_Property_01April19.pdf PDF
20B0001_Am_1_Conformed_Copy.docx DOCX document
Site_Visit_Sign_In_Sheet.pdf PDF
Wage_Determination_26Jul19.pdf PDF
W9123820B0001_Official_Solicitation.docx DOCX document
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment 5 list of changes

1. New TOC

2. Replaced Spec Section 01 11 00

3. Added Spec Section 01 30 00

4. Register for Amendment 5

5. Revised specs 01 57 19 (has 6 month period removed in 3.5.1)

6. Revised specs 13.34.19, 2.1.3 “Finish”, Part “B”. Has been revised to indicate the use of Masonry Veneer in lieu of thinset brick veneer as previously indicated.

7. Revised specs 04.20.00, 2.2.2.2.2 “Size” (Page 6) and

2.2.2.2.4 “Unit Types (Page 7) to clarify the use of Split Faced Concrete Masonry Units.

8. Revised Drawings

1. CS-104: TRACY ACP BID OPTIONS

2. CS-402: CIVIL SITE PLAN ENLARGEMENT 2 OF 3

3. A-501:

a. BLDG 130 A, B & C - GUARD BOOTH 1, 2, & 3 -

PLAN VIEW / ELEVATION

b. BLDG 134 - OVERWATCH BUILDING -

PREFABRICATED OVERWATCH

4. FP-100: BLDG 128 - VISTOR CONTROL CENTER - LIFE

SAFETY NOTES

5. FP-101: BLDG 131 - INSPECTION BUILDING - LIFE

SAFETY PLAN

6. FP-101: BLDG 133 - GATEHOUSE - LIFE SAFETY PLAN

7. A-201

a. BLDG 131 - INSPECTION BUILDING - LIFE SAFETY

PLAN

b. BLDG 133 - GATEHOUSE - LIFE SAFETY PLAN