A.01.13 A-202.pdf

PDF 235 KB Posted

Attached to
DLA Warehouse 11 Renovation Federal contract opportunity
Solicitation number
W9123620B0017
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This package includes construction drawings and specifications for renovations to Defense Supply Center Richmond Building 11. The project involves roof replacements, window repairs, exterior painting and other upgrades at the facility located in Richmond, Virginia. The solicitation was issued by the Department of the Army Corps of Engineers Norfolk District for IFB W91236-20-B-0017. Electronic bids were due by the specified date in the IFB. The specifications provide details on the scope of work including replacing all downspouts and gutters, salvaging and reinstalling roof ventilator fans, and matching the historical exterior appearance of the building.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Warehouse 11 Renovation, newest first.
File Type Posted
Warehouse 11 page 3.pdf PDF
Warehouse 11 KO Signed Page 1.pdf PDF
Warehouse 11 page 4.pdf PDF
Warehouse 11 page 2.pdf PDF
ProjNet Responses Amend 7.pdf PDF
20-B-0017 Amendment 7.pdf PDF
20-B-0017 Amendment 6.pdf PDF
A-134.pdf PDF
A-136.pdf PDF
01 33 29.pdf PDF
01 11 00.05 50.pdf PDF
A-321.pdf PDF
A-311.pdf PDF
01 32 01.00 10.pdf PDF
AD102.pdf PDF
23 52 43.00 20.pdf PDF
A-501.pdf PDF
08 51 00.pdf PDF
G-001.pdf PDF
AD103.pdf PDF
PD102.pdf PDF
A-133.pdf PDF
09 29 00.pdf PDF
A-403.pdf PDF
A-401.pdf PDF
PROJECT.pdf PDF
20B0017 Amendment 5.pdf PDF
A-132.pdf PDF
REGISTER.pdf PDF
A.01.13 A-501.pdf PDF
A.01.13 A-111.pdf PDF
A.01.13 A-112.pdf PDF
A.01.13 A-310.pdf PDF
A.01.13 Specs Table of Contents.pdf PDF
A.01.13 A-321.pdf PDF
A.01.13 AD100.pdf PDF
A.01.13 A-100.pdf PDF
A.01.13 07 54 19.pdf PDF
A.01.13 A-403.pdf PDF
A.01.13 10 81 00.pdf PDF
A.01.13 A-113.pdf PDF
A.01.13 A-201.pdf PDF
A.01.13 A-203.pdf PDF
20-B-0017 Amendment 3.pdf PDF
A.01.13 A-116.pdf PDF
WH 11 Site Visit.pdf PDF
_P_2015_01503_003_specs_RTA.pdf PDF
_RTA_Reno_to_Bldg_11_DDRV_Full_Plan_Set.pdf PDF
A.01.13 WH11 Final Specifications.pdf PDF
20-F-0017 WH 11.pdf PDF
Show all 50

DLA Warehouse 11 Renovation has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GRADE

0"

LEVEL 1

3' - 6"

49505152535455565758596061

TOP OF ROOF

33' - 6"

EXISTING OVERHEAD DOOR, TYP.REPLACE ALL DOWNSPOUTS IN KINDEXISTING LOUVER, TYP.

NEW DOWNSPOUTS FROM THE UPPER ROOF TO LOWER ROOF, TYP.

A -2

A -2

NEW METAL LADDER

REPLACE GUTTERS, TYP.

REPLACE ROOF VENTILATOR FANS

SALVAGED FROM DEMOLITION ON EXISTING

ROOF OPENINGS. PROVIDE NEW FLASHING

TO NEW ROOF MEMBRANE. PAINT FAN

HOUSING, TYP

GRADE

0"

LEVEL 1

3' - 6"

K I H G F E D C B A

TOP OF ROOF

33' - 6"

EXISTING LOUVER, TYP.OVERHEAD DOOR, TYP. NEW DOOR, REPLACE IN KIND

EXISTING LADDER

REPLACE ROOF VENTILATOR FANS SALVAGED FROM

DEMOLITION ON EXISTING ROOF OPENINGS. PROVIDE

NEW FLASHING TO NEW ROOF MEMBRANE. PAINT FAN

HOUSING, TYP

GRADE

0"

LEVEL 1

3' - 6"

61626364656667

TOP OF ROOF

33' - 6"

A-310

2_______

A-310

2_______

EXISTING LOUVER, TYP. EXISTING

OVERHEAD DOOR, TYP.

KALWALL BACKUP SYSTEM, TYP.

THIS BAY ONLY SEE SHEET A-501.

REPLACE ALL DOWNSPOUT IN KIND

NEW DOWNSPOUTS FROM THE

UPPER ROOF TO LOWER ROOF, TYP.

A -2

REPLACE GUTTERS, TYP.

REPLACE ROOF VENTILATOR FANS SALVAGED FROM

DEMOLITION ON EXISTING ROOF OPENINGS. PROVIDE

NEW FLASHING TO NEW ROOF MEMBRANE. PAINT FAN

HOUSING, TYP

GRADE

0"

LEVEL 1

3' - 6"

1 2 3 4 5 6 7 8 9 10 11 12 13

A-310

1_______

A-310

1_______

TOP OF ROOF

33' - 6"

REPLACE ALL DOWNSPOUTS IN KIND EXISTING

LOUVER, TYP.

NEW DOWNSPOUTS FROM THE UPPER

ROOF TO LOWER ROOF, TYP.

A -2

23 3 3 3 3 3

NEW METAL LADDER

REPLACE GUTTERS, TYP.

REPLACE ROOF VENTILATOR FANS SALVAGED FROM

DEMOLITION ON EXISTING ROOF OPENINGS. PROVIDE

NEW FLASHING TO NEW ROOF MEMBRANE. PAINT FAN

HOUSING, TYP

NEW ROOF, INSULATION, FLASHING

AND TRIM, TYP.

GRADE

0"

LEVEL 1

3' - 6"

13 14 15 16 17 18 19 20 21 22 23 24 25

TOP OF ROOF

33' - 6"

REPAIR WINDOW IN KIND REPLACE ALL DOUWNSPOUTS IN KINDEXISTING LOUVER, TYP.

NEW DOWNSPOUTS FROM THE UPPER ROOF TO LOWER ROOF, TYP.

A -2

A -2

REPAIR WINDOW IN KIND

REPLACE GUTTERS, TYP. 1

REPLACE ROOF VENTILATOR FANS SALVAGED FROM

DEMOLITION ON EXISTING ROOF OPENINGS. PROVIDE

NEW FLASHING TO NEW ROOF MEMBRANE. PAINT FAN

HOUSING, TYP

NEW ROOF, INSULATION, FLASHING

AND TRIM, TYP.

GENERAL NOTES

1. ALL EXTERIOR BUILDING MODIFICATION

SHALL MATCH EXISTING APPEARANCE

TO MAINTAIN HISTORICAL REQUIREMENTS

2. ALL EXTERIOR METAL TO BE PAINTED

PT-2 EXCLUDING FIRE HYDRANTS,

GUARDRAILS, AND BOLLARDS.

3. CLEAN AND PAINT STRUCTURAL STEEL,

COLUMNS, BRACING, BOLLARDS AND

LOUVERS.

4. CLEAN AND PAINT INTERIOR WINDOW

FRAMES, EXTERIOR CANOPIES AND

EXTERIOR STAIR RAILS.

WINDOW TAG, SEE SHEET A-602

0' 8' 16' 32' 64'

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N O

R F

O L K

D

IS

T R

IC

T

F

R O

N T

S T

R E

E T

N O

R F

O L K

V

IR

G

IN

IA

J

O N

E S

F R

A N

K L

IN

R D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

F

IL

E N

A M

E

C A

T E

G O

R Y

C O

D E

N

A O

F

IL

E N

O

W -2

-B

-0

W -1

-F

-0

D S

A L T

S M

A N

FOR OFFICIAL USE ONLY

FOR CONSTRUCTION

A-202

E X

T E

R

IO

R E

L E

V A

T

IO

N S

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D R

IC

H

M O

N D

V A

R M

O R

S O

N

T S

H O

U S

E

P Z

O O

K

M

A R

C H

R E

N O

V A

T

IO

N S

T O

B U

IL

D

IN

G

D

D R

V

P R

O J E

C T

N U

M B

E R

P

.0

.0

A -2

.D

W G

1/16" = 1'-0"A-202

EXTERIOR ELEVATION - WEST

ELEVATION - BAY I & K - PHASE 5

1/16" = 1'-0"A-202

EXTERIOR ELEVATION - SOUTH

ELEVATION

1/16" = 1'-0"A-202

EXTERIOR ELEVATION - WEST

ELEVATION - BAY L - PHASE 6

1/16" = 1'-0"A-202

EXTERIOR ELEVATION - EAST

ELEVATION - BAY A & B - PHASE 1

1/16" = 1'-0"A-202

EXTERIOR ELEVATION - EAST

ELEVATION - BAY C& D - PHASE 2

A

M E

N D

M E

N T

A P

R

File details come from the government source that posted it. Updated .