AMENDMENT_0002_Attachment.pdf
PDF 881 KB Posted
- Attached to
- Aviation Maintenance Instructional Building, Fort Eustis, VA Federal contract opportunity
- Solicitation number
- W91236-18-B-0018
About this file
Amendment 0002 Attachment
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B.01.02_Abstract_of_Offers_Continuation_Sheet_Page_2_W91236-18-B-0018_AMIB.pdf | ||
| B.01.02_Abstract_of_Offers_Continuation_Sheet_Page_3_W91236-18-B-0018_AMIB.pdf | ||
| B.01.02_Abstract_of_Offers_Pg._1_W91236-18-B-0018_AMIB.pdf | ||
| W91236-18-B-0018_Amendment_0002.pdf | ||
| W91236-18-B-0018_Amendment_0001.pdf | ||
| Amendment_0001_Attachment.pdf | ||
| Site_Visit_Attendance_Sheet_18-B-0018.pdf | ||
| A.01.13_RTA_AMIB_DWGS_VOL_1.pdf | ||
| A.01.13_RTA_AMIB_DWGS_VOL_2.pdf | ||
| A.01.38_PN077779_AMIB_GEOTECHNICAL_REPORTS_VOL_4.pdf | ||
| Site_Visit_Access_Spreadsheet.xls | XLS spreadsheet | |
| LETTER_OF_COMMITMENT_FOR_SUBCONTRACTOR_sample.docx | DOCX document | |
| A.07.23_W91236-18-B-0018_Aviation_Maintenance_Instruction_Building_FINAL.pdf | ||
| A.01.38_PN077779_AMIB_SPECIFICATIONS_RTA_VOL_1.pdf | ||
| A.01.38_PN077779_AMIB_SPECIFICATIONS_RTA_VOL_3.pdf | ||
| A.01.38_PN077779_AMIB_SPECIFICATIONS_RTA_VOL_2.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Aircraft Maintenance Instructional Building 793AMIB
RTA SUBMITTAL
1.8 WARRANTY
Furnish manufacturer's no-dollar-limit warranty for the metal wall panel system. The warranty period is to be no less than twenty (2) years from the date of Government acceptance of the work. The warranty is to be issued directly to the Government. The warranty is to provide that if within the warranty period the metal wall panel system shows evidence of corrosion, perforation, rupture or excess weathering due to deterioration of the wall panel system resulting from defective materials and correction of the defective workmanship is to be the responsibility of the metal wall panel system manufacturer. Repairs that become necessary because of defective materials and workmanship while metal wall panel system is under warranty are to be performed within 24 hours after notification, unless additional time is approved by the Contracting Officer. Failure to perform repairs within 24 hours of notification will constitute grounds for having emergency repairs performed by others and not void the warranty.
PART 2 PRODUCTS
2.1 PANEL MATERIALS
2.1.1 Steel Sheet
Roll-form steel wall and liner panels to the specified profile, minimum 22 gauge thickness for all steel sheet panel materials. Material must be plumb and true, and within the tolerances listed:
a. Galvanized Steel Sheet conforming to ASTM A653/A653M and AISI SG03-3.
c. Individual panels to have continuous length to cover the entire length of any unbroken wall area with no joints or seams and formed without warping, waviness, or ripples that are not part of the panel profile and free of damage to the finish coating system.
e. Provide panels with thermal expansion and contraction consistent with the type of system specified.
1. Profile shall be mfr. standard flush panels with reveal joints.
Size and layout to match drawings.
2. Smooth, flat surface texture.
2.1.2 Foam-Insulation Core Wall Panel
Provide factory-formed steel wall panel assembly fabricated from two sheets of metal with modified polyisocyanurate or polyurethane foam insulation core foamed-in-place during fabrication with joints between panels designed to form weather-tight seals. Include accessories required for weather-tight installation. Insulated metal panels shall serve as integrated air and vapor barrier, and shall include all flashing, pressure equalized seal plates and accessories required for an airtight and watertight installation.
a. Closed-Cell Content: 90 percent when tested according to ASTM D6226.
b. Density: 2.0 to 2.6 lb/cu. ft. when tested according to
ASTM D1622/D1622M.
c. Compressive Strength: Minimum 20 psi when tested according to
SECTION 07 42 63 Page 11
2.5.3 Sealants
Elastomeric type containing no oil or asphalt. Exposed sealant must cure to a rubberlike consistency. Concealed sealant must be the non-hardening type. Seam sealant must be factory-applied, non-skinning, non-drying, and must conform to the roofing manufacturer's recommendations. Silicone-based sealants must not be used in contact with finished metal panels and components unless approved otherwise by the Contracting Officer.
2.5.4 GASKETS AND INSULATING COMPOUNDS
Nonabsorptive and suitable for insulating contact points of incompatible materials. Insulating compounds must be nonrunning after drying.
2.6 RIGID INSULATION
Provide polyisocyanurate insulation to meet thickness and r-value indicated on drawings. Refer to PVC roofing specification for insulation and cover board requirements.
2.7 UNDERLAYMENT FOR WOOD SUBSTRATES
ASTM D226/D226M, Type I perforated, covered by water-resistant rosin sized building paper.
2.8 LINER PANELS
Fabricate liner panels of the same material as roof panels, and formed or patterned to prevent waviness and distortion. Liner panels must have a factory applied, one mil thick minimum painted coating on the inside face and a prime coat on the liner side.
2.9 SNOW GUARDS
General: Prefabricated, noncorrosive units designed to be installed without penetrating sheet metal roofing; complete with predrilled holes, clamps, or hooks for anchoring. Seam-Mounted, Bar-Type Snow Guards: Rail- or fence-type assembly consisting of stainless-steel rods, bars, or pipe held in place by stainless-steel clamps attached to vertical ribs of standing-seam sheet metal roofing.
a. Stainless-Steel finish.
PART 3 EXECUTION
Do not install building construction materials that show visible evidence of biological growth.
3.1 EXAMINATION
Examine surfaces to receive standing seam metal roofing and flashing.
Ensure that surfaces are plumb and true, clean, even, smooth, as dry and free from defects and projections which might affect the installation.
3.2 PROTECTION FROM CONTACT WITH DISSIMILAR MATERIALS
3.2.1 Cementitious Materials
Paint metal surfaces which will be in contact with mortar, concrete, or
SECTION 07 61 14.00 20 Page 13
a. Treads: Machine wheel treads concentric with bearing seats. The clear distance between flanges shall not exceed the width of the rail by more than 1/8 inch at the tread nor more than 1/4 inch at the edge of the flange. Machine internal bearing seats accurately for a press fit.
Heat treat wheels 18 inches or greater in diameter to obtain a rim hardness of 320 Brinnel.
b. Wheel bearings: Provide tapered roller or spherical bearings, either internal or cartridge type, arranged so that both horizontal and vertical loads shall be transferred to the rail only through the bearing. Bearings shall be tightly sealed and equipped with high-pressure grease fittings.
2.1.7.2 Fixed Pancake Top Guide Rollers
Horizontal type; each with single or double steel rollers of a suitable diameter and thickness for satisfactory performance under the designated load conditions and top guide system used. Provide permanently lubricated bearings. Rollers shall be stainless steel.
2.1.8 Weather Stripping
Provide adjustable and readily replaceable material. Provide as indicated and on vertical edges, sills, and heads to afford a weathertight installation.
2.1.8.1 Neoprene
Use flap-type, two-ply, cloth-inserted neoprene or extruded, double flap, single or dual opposed solid neoprene material on vertical edges and sills.
The two-ply material shall have a minimum thickness of 1/8 inch and shall be retained continuously for its full length and secured with rust-resistant fasteners 12 inches o.c. Extruded weather stripping with heavy center section shall be attached at 12 inches o.c., but continuous bar may be omitted. Clearance between metal parts on vertical edges of leaves and between leaves and jambs which are to be weather-stripped shall be as indicated.
2.1.8.2 Metallic
Form head weather stripping material between each leaf and the top guide system of not lighter than 18 gage galvanized sheet steel or flap-type, cloth-inserted neoprene, as indicated.
SECTION 08 34 16.10 Page 5
2.1.7.3 Vertical Floating Head Top Guide Rollers - DELETED
2.1.8.3 Hanging Head Flashing
Provide with the top guide system specified in Section 05 12 00 STRUCTURAL STEEL. Provide cloth-inserted neoprene weathering fastened to top of door leaves to engage the head flashing when doors are closed.
2.1.9 Fasteners
Either zinc-coated or cadmium-plated steel.
2.1.10 Sealant
Single-component or multicomponent elastomeric type conforming to ASTM C920, Type S or M, Grade NS, Class 12.5, Use NT. Provide a sealant that has been tested on the types of substrate to which it will be applied.
2.1.11 Primer
Red iron oxide, zinc oxide type, SSPC Paint 25.
2.1.12 Starters
Provide magnetic reversing starters in NEMA ICS 1, Type 12 enclosures equipped with access door-controlled, fused safety disconnect switches.
Starters shall be factory wired with overload and undervoltage protection, mechanical and electrical interlocks, auxiliary contacts, relays and timing devices as required, control circuit transformers, and a numbered terminal strip. The control circuit transformer shall reduce the voltage in the control circuits to 115 volts or less, and shall conform to UL 506.
2.1.13 Electrical
Provide conduit, wire, flexible cables, boxes, devices, and accessories, and install trolley duct,under Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. If permanent electrical power is not available when door installation is complete, provide temporary power under Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM, for testing and adjusting the doors.
2.2 FABRICATION
2.2.1 Doors
2.2.1.1 Frames and Framing
Door leaves shall be of welded or bolted construction. Joints shall develop 100 percent of the strength of the framing members. Vertical members shall be continuous throughout the height of the door. When required, prepare splices to facilitate field assembly in accordance with standard practice. Frames and framing members shall be true to dimensions and square in all directions; no leaf shall be bowed, warped, or out of line in the vertical or horizontal plane of the door opening by more than 1/8 inch in 20 feet. Provide diagonal bracing so that the completed leaf assembly will be braced to withstand shipping, assembly, and operational loads. Exposed welds and welds which interfere with the installation of various parts such as cover sheets shall be ground smooth.
SECTION 08 34 16.10 Page 6
2.2.1.2 Exterior Covering and Interior Liner Sheets
Flat sheets shall be fastened to the frame either by edge welding, plug welding, or threaded fasteners 12 inches o.c. Where flat sheets are attached as either exterior covering or interior liner sheets, the clear unsupported area shall not exceed 25 square feet. Make edges of exterior sheets weathertight with sealant.
2.2.2 Locking Devices
Do not provide locking devices on motor-operated hangar doors.
2.2.3 Tractor Pulls
Provide tractor pulls so that leaves can be towed by a tractor or similar equipment in the event of power failure. The tractor pull shall be designed for drive force to tow door or 5000 pounds whichever is greater.
Minimum thickness steel plate shall be 3/8 inch.
2.2.4 Track Cleaners
Provide a device to clear debris from the rail head and wheel flange grooves as the leaf is moved.
2.2.5 Cable System for Group Doors
The minimum size for the cable which interconnects the leaves shall be 3/8 inch; the cables shall be improved plow steel with lubricated hemp centers or wire rope cores. Sheaves over which the cables operate shall have a diameter of at least 18 cable diameters and either sealed ball-or roller-type bearings or graphite bronze bearings of a sufficient capacity for the operating loads. Grease fittings shall be provided for the sheave bearings unless permanently lubricated bearings are used.
2.3 OPERATION
2.3.1 Hangar Door Types
Hangar doors shall be biparting .
SECTION 08 34 16.10 Page 7
2.3.1.1 Individually Operated Doors - DELETED
2.3.1.2 Floating Group Doors - DELETED
DIVISION 3: INTERIOR CONCRETE PAINT TABLE
Primer: Intermediate: Topcoat:
MPI 77 MPI 77 MPI 77
System DFT: 4 mils
Note: Primer may be reduced for penetration per manufacturer's instructions.
DIVISION 4: INTERIOR CONCRETE MASONRY UNITS PAINT TABLE
A. New Concrete masonry (typical in GIB unless otherwise noted or specified):
High Performance Architectural Waterbased Polyeurthane
MPI INT 4.2D-G4 (Satin) Filler Primer: Intermediate: Topcoat:
MPI 4 N/A MPI 140 MPI 140
System DFT: 11 mils
Fill all holes in masonry surface
B. New Concrete masonry units in high bay (AMIB) and storage building (GSE) and other high humidity areas unless otherwise specified:
Epoxy MPI INT 4.2G-G6 (Gloss) Filler: Primer: Intermediate: Topcoat:
MPI 116 N/A MPI 77 MPI 77
System DFT: 10 mils
Fill all holes in masonry surface
DIVISION 5: INTERIOR METAL, FERROUS AND NON-FERROUS PAINT TABLE
INTERIOR STEEL / FERROUS SURFACES
A. Metal, not otherwise specified except floors, hot metal
DIVISION 6: INTERIOR WOOD PAINT TABLE
A. New Wood and plywood not otherwise specified:
High Performance Architectural Water Based Polyurethane
High Performance Architectural Water Based Polyurethane - (Basis of design - Scuffmaster - Scrubtough)
SECTION 09 90 00 Page 22 surfaces, and new prefinished equipment:
1. High performance Architectural Latex MPI INT 5.4F-G2 (Flat)
Primer:
MPI 95
Intermediate:
MPI 138
Topcoat:
MPI 138
System DFT: 5 mils
DIVISION 6: INTERIOR WOOD PAINT TABLE
New; (Eggshell) Primer, Intermediate, and Topcoat required as per manufacturer's recommendation.
* Product shall meet ASTM D2486 and have a a durability of a minimum of 8,000 scrubs.
* Product shall have a Low VOC with a minimum content of 142 g/l.
* Paint shall have a natural or additive that inhibits growth of mold, mildew, and bacteria on the dried paint film.
B. New Wood Doors; Stained:
Stained, oil-modified polyurethane New; MPI INT 6.3E-G4 / Existing; MPI RIN 6.3E-G4 Stain: Primer: Intermediate: Topcoat:
MPI 90 MPI 57 MPI 57 MPI 57
System DFT: 4 mils
Note: Sand between all coats per manufacturers recommendations.
DIVISION 9: INTERIOR PLASTER, GYPSUM BOARD, TEXTURED SURFACES PAINT TABLE
A. New Wallboard not otherwise specified:
High Performance Architectural Water Based Polyurethane - High Traffic Areas (Basis of design - Scuffmaster - Scrubtough)
New; (Eggshell) Primer, Intermediate, and Topcoat required as per manufacturer's recommendation.
* Product shall meet ASTM D2486 and have a a durability of a minimum of 8,000 scrubs.
* Product shall have a Low VOC with a minimum content of 112 g/l.
* Paint shall have a natural or additive that inhibits growth of mold, mildew, and bacteria on the dried paint film.
B. New Wallboard in toilet rooms, stairwells, and other high humidity areas not otherwise specified:
High Performance Architectural Water Based Polyurethane - (Basis of design - SCuffmaster - Armor)
New; (Eggshell) Primer, Intermediate, and Topcoat required as per manufacturer's recommendation.
* Product shall meet ASTM D2486 and have a a durability of a minimum of 25,000 scrubs.
* Product shall have a Low VOC with a minimum content of 142 g/l.
* Paint shall have a natural or additive that inhibits growth of mold, mildew, and bacteria on the dried paint film.
-- End of Section --
SECTION 09 90 00 Page 23
C. Gypsum ceiling not otherwise specified:
New: MPI INT 9.2A-G3 (Eggshell) / Existing: MPI RIN 9.2A-G3 (Semigloss)
Primer:
MPI 50
Intermediate:
MPI 52
Topcoat:
MPI 52
System DFT: 4 mils
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
CO
CO
CO
CO
D
S
D
S
D
S
D
S
D
C
P
C
P
C
P
D
D
D
D
D
D
D
D
D
D
D
D
D
D
GRAVEL PARKING
AREA TO BE REMOVED
PAVERS TO BE REMOVED
SANITARY PIPE TO
BE REMOVED BY OTHERS
PS
LIMITS OF CONSTRUCTION
DRAINAGE PIPE
TO BE REMOVED
MU
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
S D
S D
C
P
C
P
D
D
D
D
D
REMOVE CONCRETE SLAB TO
REMOVE RAILROAD
TRACKS AND
REPAIR CONCRETE
AS NEEDED
UNDERGROUND TANKS, PIPING AND
CONCRETE SLAB TO BE REMOVED
(TANKS INCLUDE 2-25,000 GAL.
FIBERGLASS HEATING OIL TANKS)
SANITARY PIPE TO BE REMOVED BY OTHERS
G
G
G
G
G
G
G
EXISTING JOINT
LIMITS OF CONSTRUCTION
PSMU
F
M
F
M
W
S
L
S
D
S
D
D
D
D
D
D
D
LIMITS OF CONSTRUCTION
NOTE: BLDG.853 IS A MASONRY STRUCTURE WITH A WOOD FRAME AND SHINGLE ROOF.
PSMU
E
E
E
E
E
E
E
E
E
E
E
SD
SD
SD
S
D
S
D
S D
S D
S D
S D
S
D
S
D
E
E
E
E
E
E
E
E
E
E
E
E
S
D
S
D
SAW CUT
PARKING AREA
G
G
G
G
G
TREES TO BE
PRESERVED
TREES TO BE
PRESERVED
REMOVE
BOLLARDS
STEEL TANKS TO
BE REMOVED
(SEE INSET THIS
SHEET)
REMOVE CONCRETE
PEDESTAL
LIMITS OF CONSTRUCTION
SANITARY PIPE TO BE REMOVED
BY OTHERS
PS
MU
TP
8'-4"
24'-4"
3'-4"
8" (TYP)
8'-7"Ø 8'-7"Ø
SIMPLEX
AUTO-FILLER
1" STEEL
PIPE
2" STEEL
PIPE.
1" STEEL
PIPE.
BLDG 2116
4,000 U.S. GALLON
SINGLE WALL
STORAGE TANK
(TYP OF 2).
STEEL ACCESS STAIRWAY
WITH LANDING AND SAFETY
RAILINGS (TYP OF 2). TOP
LANDING IS APPROXIMATELY
5-FT ABOVE TOP OF SLAB.
TOP OF DIKE WALL
APPROXIMATELY 1'-4"
ABOVE TOP OF SLAB.
TOP OF DIKE WALL
APPROXIMATELY
3'-0" ABOVE GRADE.
STEEL
LOUVER
2" STEEL
PIPE.
2" STEEL
PIPE.
US Army Corps of Engineers ®
SHEET ID
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I L
E
N
A M
E
I S
S U
E
D
A T
E
F I L
E
N
U M
B E
R
1 2 3 4 5
D
C
B
A
SHEET OF
A V
I A
T I O
N
M
A I N
T E
N A
N C
E
T
R A
I N
I N
G
F
A C
I L
I T
Y
F O
T
U S
T I S
V
A
N O
R F
O L
K
D
I S
T R
I C
T
N O
R F
O L
K
V
A
R T
A
S
U B
M I T
T A
L
J
W
A L
L
A
B
R A
D S
H A
W
J
W
A L
L
J U
N
P R
O J E
C
C O
N T
R A
C
M A
R K
D E
S C
R I P
T I O
N D
A T
E
J
W
A L
L
CD904
D E
M O
L I T
I O
N
P
L A
B
L D
G S
DEMOLITION PLAN (BLDG. 653)
SCALE: 1"=40'
DEMOLITION PLAN (BLDG. 801)
SCALE: 1"=40'
DEMOLITION PLAN (BLDG. 853)
SCALE: 1"=40'
40' 80'0
N
DEMOLITION PLAN (BLDG. 2116)
SCALE: 1"=40'
LEGEND:
LINEAR FEATURE REMOVAL
STRUCTURE AND PAVEMENT DEMOLITION
NOTES:
1. FOR BLDG. 2116 REMOVE TWO (2) ABOVE GROUND STEEL STORAGE
TANKS (4000 GAL. EACH). BOTH TANKS HAVE BEEN CLEANED AND
CLOSED (12 MAY 2011).
2. REMOVE ASSOCIATED TANK PIPING AND ACCESSORY EQUIPMENT.
(BLDG. 801 & BLDG. 2116)
3. REMOVE GALVANIZED STEPS. (BLDG. 2116)
4. REMOVE CONCRETE SPILL CONTAINMENT STRUCTURE. (BLDG. 2116)
5. COORDINATE WITH VIRGINIA NATURAL GAS FOR REMOVAL OF GAS
LINE, MARCIE BEVINS AT M.J. BEVINS @ SOUTHERNCO.COM OR
757-438-0459.
6. SEE SHEET CD907 AND CD908 FOR RECORD DRAWINGS. (BLDG. 2116)
7. UTILITIES SHOWN ON THIS SHEET ARE FROM INSTALLATION GIS
RECORDS AND WERE NOT FIELD VERIFIED.
8. ITEMS TO BE DEMOLISHED IN INSET ARE NOTED BY DASHED LINE.
9. TREES ADJACENT TO BLDG 2116 TO BE PRESERVED. COORDINATE
WITH 733 CED/ACOE CONCERNING POTENTIAL TREE TRIMMING AND
ROOT IMPACTS.
TREE PROTECTION
LIMITS OF CONSTRUCTION
PS
PERMANENT SEEDING
B I D
T
I O
N
SCALE: 1" = 40'
MU
MULCHING
TP
KEYED DEMOLITION NOTES
TOP OF GRADE VARIES ALONG LENGTH OF WALL FROM
3'-0" (AS NOTED ON THE PLAN) T0 APPROXIMATELY 1'-10"
AT THE POINT INDICATED BY THIS KEY NOTE.
STEEL ACCESS STAIRWAY WITH CROSSOVER LANDING.
TOP OF LANDING IS APPROXIMATELY 4'-0" ABOVE GRADE.
PIPING HAS BEEN PREVIOUSLY DISCONNECTED AT THE
POINT INDICATED AND ABANDONED IN PLACE.
INSET FOR STEEL TANKS REMOVAL (BLDG. 2116)
SCALE: NTS
R E
V I S
I O
N
T
O
N
O T
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JACKSON AVE
AutoCAD SHX Text
WILLIAMSON LOOP
AutoCAD SHX Text
WILLIAMSON LOOP
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
LEE BLVD
AutoCAD SHX Text
SHRUBS
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
KELLS DRIVE
AutoCAD SHX Text
TREES
AutoCAD SHX Text
TREES
AutoCAD SHX Text
AutoCAD SHX Text
WILSON AVE
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
59' - 6"
AMIB - ROOF TRUSS
RIDGE
MEMBRANE FLASHING
ROOFING ADHESIVE 80 MIL THERMOPLASTIC
SINGLE PLY ROOFING
MEMBRANE
R-36 RIGID INSULATION
1/2" GWB SHEATHING
1/2" ANCHOR BOLT
PREFINISHED ROOF
EDGE METAL
CONTINUOUS
CLEAT
TREATED WOOD
BLOCKING
MTL. FASCIA
MTL. DECK, SEE STRUCTURAL
MEMBRANE
AIR BARRIER
CLOSURE
ANGLE
CONTINUOUS
CLEAT
PRE-FINISHED
MTL. TRIM
BUTYL SEALANT
AIR BARRIER
FLASHING
SEAL PLATE
I.M.P. CLIP SYSTEM
BUTYL SEALANT
3" INSULATED METAL
PANEL
STEEL GIRT
A
SPRAY FOAM INSULATION
0"
TOP OF GROUND FLOOR
SLAB
-2' - 8"
TOP OF FOUNDATION
10' - 0"
AMIB - TOP OF MASONRY
WALL
A
R-22 INSULATED METAL WALL
PANEL
CONT. AIR BARRIER MEMBRANE
TRANSITION MEMBRANE W/ BUTYL
SEALANT TYP.
RIGID INSULATION, R-16.8
FLUID APPLIED AIR BARRIER
2" X 6" CFMF
PRECAST CONCRETE W/
WEEP HOLE (PC-4)
1" RAD. BULLNOSE TOP
COURSE OF CMU
1" TECTUM PANEL, TYP @
AMIB EXTERIOR WALLS
2" X 3 5/8" CFMF
5/8" GYP SHEATHING
TUBE FRAMING, SEE
STRUCT.
FACE OF STRUCT COLUMN
PRECAST WATER TABLE
(PC-1)
BRICK VENEER (FB-1)
8" SPLIT FACE CMU
MORTAR MESH
THROUGH WALL FLASHING
W/ WEEP HOLE AT 32" O.C.
GROUT SOLID
ADJUSTABLE WALL TIE
AIR SPACE
-5' - 8"
TOP OF DROPPED GB
1/2" EXPANSION JOINT
GRADE
R-15 RIGID INSULATION
AT 2'-0" FROM EDGE OF
FOOTING
MIN. 10 MIL VAPOR
BARRIER
MIN. 6" CAPILLARY
BARRIER
1" RIGID INSULATION
R-22 INSULATED METAL WALL
PANEL
AIR BARRIER
CLOSURE FLASHING
2" X 6" CFMF
1" TECTUM PANEL, TERMINATES AT 20'-0"
A.F.F. TYP. @ AMIB EXTERIOR WALLS.
2" X 3 5/8" CFMF
5/8" GYP SHEATHING
TUBE FRAMING, SEE
STRUCT.
METAL PANEL STACK JOINT W/
WEEP HOLES
FACE OF STRUCT. COLUMN
SEALANT, TYP.
20' - 0"
GSE - GIRT - 2
36' - 8"
STACKED JOINT
10' - 0"
AMIB - TOP OF MASONRY
WALL
1' - 4"
R-22 INSULATED METAL WALL
PANEL
AIR BARRIER MEMBRANE
TRANSITION MEMBRANE W/ BUTYL
SEALANT TYP.
RIGID INSULATION, R-16.8
FLUID APPLIED AIR BARRIER
2" X 6" CFMF
PRECAST CONCRETE W/
WEEP HOLE (PC-4)
1" TECTUM PANEL
2" X 3 5/8" CFMF
5/8" GYP SHEATHING
A-501
CONT. AIR BARRIER MEMBRANE
SEAL PLATE
FLUID APPLIED AIR
BARRIER
5/8" GYP SHEATHING
BUTYL SEALANT
COLD FORMED METAL
FRAMING
CMU BLOCK
METAL FLASHING
BUTYL SEALANT
AIR BARRIER SEALANT
BUTYL SEALANT
BACKER ROD AND
SEALANT
PRECAST (PC-4)
1" RIGID
INSULATION
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
SHEET OF
A-501
SE
C
TI
O
N D
E T
AI
LS
AV
IA
TI
O
N M
AI
NT
EN
AN
CE
T
RA
IN
IN
G
F
AC
IL
IT
Y F O
RT
E
US
TI
S, V
A .
N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
P.
W
O O
D
S.
H
EN
D
R
IC
K
D . G
EB
LE
R
M . J
O H
N
SO
N
JU
N
E
PR
O
JE
C T
N O
C O
N
TR
AC
T
N O
AR
C
H
IT
E C
TU
R
AL
A -5
648294
12" 24"
SCALE: 1 1/2" = 1' - 0"
0'
6" 12"
SCALE: 3" = 1' - 0"
0'
SCALE: 1 1/2" = 1'-0"1 TYP. HIGH BAY EAVE DETAIL
A-311
SCALE: 1 1/2" = 1'-0"3 MASONRY BASE DETAIL AT AMIB
A-311
SCALE: 1 1/2" = 1'-0"
A-311
2 TYPICAL STACKED METAL PANEL DETAIL (AMIB WALL)
SCALE: 1 1/2" = 1'-0"4
METAL PANEL TRANSITION DETAIL (AMIB
EAST/WEST WALL)
SCALE: 6" = 1'-0"5 WEATHER BARRIER TRANSITION
A-501
3" 6"
SCALE: 6" = 1' - 0"
0'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ID
/2
4/
B
22 2423
A-631
A-631
A-631
A-631
A
B
BRICK VENEER
BACKER ROD AND
SEALANT
FLAT PROFILE INSULATED METAL
PANEL WITH IMPACT / ABRASION
RESISTANT EXTERIOR FINISH. SEE
HANGAR DOOR ELEVATIONS DOOR
FINISH COLORS.
1/8" X CONT. NEOPRENE GASKET
FASTENED W/ GALVANIZED
RETAINER BAR PER MFR
RECOMMENDATIONS
METAL CLOSURE TRIM
HEAVY DUTY METAL JAMB
FLASHING / RUB PLATE
ROLLING HANGAR DOOR BOTTOM RAIL PER
DOOR MFR, INSTALL HEAT TRACE WIRE FOR
FREEZE PROTECTION, SEE ELECTRICAL
CMU STRUCTURAL WALL
STEEL COLUMN, REFER TO
STRUCTURAL DRAWINGS
1'
4" 1'
0"
1" 3'
0"
2'
0"
METAL WALL PANEL JAMB
COVER PER MFR
GYP SHEATHING
AIR BARRIER MEMBRANE
A
RIGID INSULATION, R-16.8
1/8" X CONT. NEOPRENE GASKET
FASTENED W/ GALVANIZED
RESTRAINER BAR PER MFR
RECOMMENDATIONS.
HEAVY DUTY METAL
JAMB FLASHING /
RUB PLATE
FORGED EYEBOLT FOR
TRACTOR PULL PER MFR
STEEL HANGAR DOOR
FRAME
PREFORMED METAL
PANEL, TYP.
FORGED EYEBOLT FOR TRACTOR
PULL PER MFR.
HEAVY DUTY METAL JAMB FLASHING/
RUB PLATE
FASTENER PER METAL PANEL MFR.TRIM WEATHER SAFETY SEAL PER
HANGAR DOOR MFR.
PANEL ACTS AS AIR BARRIER AND
VAPOR RETARDER, SEAL JOINT
BETWEEN PANELS PER MFR
INSTRUCTIONS
FLAT PROFILE INSULATED METAL PANEL WITH IMPACT /
ABRASION RESISTANT EXTERIOR FINISH, SEE HANGAR
DOOR ELEVATIONS FOR FINISH COLORS
STEEL HANGAR DOOR FRAMING PER
MFR, PROVIDE AS NECESSARY TO
INSTALL EXTERIOR METAL PANELS
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
SHEET OF
A-631
EN
LA
R G
ED
H
AN
G
AR
D
O O
R
D
ET
AI
LS
AV
IA
TI
O
N M
AI
NT
EN
AN
CE
T
RA
IN
IN
G
F
AC
IL
IT
Y F O
RT
E
US
TI
S, V
A .
N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
P.
W
O O
D
S.
H
EN
D
R
IC
K
D . G
EB
LE
R
M . J
O H
N
SO
N
JU
N
E
PR
O
JE
C T
N O
C O
N
TR
AC
T
N O
AR
C
H
IT
E C
TU
R
AL
A -6
648314
SCALE: 1/4" = 1'-0"
ENLARGED HANGAR DOOR PLAN
SCALE: 1 1/2" = 1'-0"2 HANGAR DOOR JAMB DETAIL
A-631
SCALE: 1 1/2" = 1'-0"3 HANGAR DOOR MEETING DETAIL
A-631
SCALE: 1 1/2" = 1'-0"4 HANGAR DOOR JAMB MEETING
A-631
4' 8' 12'
SCALE: 1/4" = 1' - 0"
0'
12" 24"
SCALE: 1 1/2" = 1' - 0"
0'
SCALE: 1 1/2" = 1'-0"5 HANGAR DOOR PANEL TRANSITION
A-631
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ID
/2
3/
FINISH LEGEND
ACT ACOUSTICAL CEILING TILE
ALUM ALUMINUM
AWP ACOUSTICAL WALL PANEL
CLR CLEAR
CONC CONCRETE
CPT CARPET
EXIST EXISTING
EXP EXPOSED
FF FINISHED FLOOR
FIN FINISH / FINISHED
FLR FLOOR
GL GLASS
GR GROUT
LAM LAMINATE
LIN LINOLEUM
MTL METAL
PAT PATTERN
PNT PAINT (PAINTED)
POL POLISHED
PT PORCELAIN TILE
PREFIN PREFINISHED
PWD PLYWOOD
RB RESILIENT BASE
RBR RUBBER
REC RECESSED
RM RECESSED MAT
RLG RAILING
RTF RUBBER TILE FLOOR
SC SEALED CONCRETE
SDT STATIC DISSIPATIVE TILE
SM SHEET METAL
SS SOLID SURFACE
SST STAINLESS STEEL
TP TOILET PARTITION / TILE PATTERN
TRTD TREATED
VCT VINYL COMPOSITION TILE
VWC VINYL WALL COVERING
WB WINDOW BLIND
WD WOOD
WSCT WAINSCOT
FINISH LEGEND NOTES
1. MANUFACTURES REFERENCED ARE INTENDED TO
ESTABLISH COLOR, PATTERN, AND FINISH ONLY AND ARE
NOT INTENDED TO LIMIT SELECTION FROM OTHER
MANUFACTURES. SUBSTITUTE PRODUCTS SHALL BE
SUBMITTED ALONG WITH SAMPLES TO THE INTERIOR
DESIGNER FOR APPROVAL.
2. MATCH FINISH OF COVERS FOR RETURN DUCTS, VENTS
AND REGISTERS IN DRYWALL CEILINGS AND WALLS TO
ADJACENT SURFACE.
3. IN STAIRWELLS, EXPOSED CEILING STRUCTURE, METAL
DECKING, DUCTWORK TO BE PAINTED (PNT2). IN ALL OTHER
LOCATIONS, PAINT PNT1.
4. NOT USED.
5. ALL DOOR HARDWARE FINISH TO BE ALUMINUM/ SATIN
STAINLESS FINISH.
6. ALL ELECTRICAL PLATE AND LIGHT SWITCH COVERS TO
BE SATIN NICKEL.
7. APPLY ADA COMPLAINT TRANSITION STRIPS AT ALL
FLOOR CHANGES. CENTER UNDER DOOR. RESILIENT
TRANSITION STRIPS SHALL MATCH FLOOR COLOR OR
RUBBER BASE. METAL TRANSITIONS STRIPS SHALL MATCH
COLOR OF CLEAR ANODIZED ALUMINUM OR STAINLESS
STEEL. TRANSITION STRIPS SHALL BE SCHLUTER, RENO-
AEVT,COLOR: ALUMINUM". PROVIDE AT CHANGE OF FLOOR
MATERIAL TYPE. CENTER UNDER DOOR.
8. INSTALLED STAINLESS STEEL EDGE PROTECTOR ON
TOP OF EXPOSED EDGES OF PORCELAIN TILE ON WALLS
INSTALLATIONS..
9. PROVIDE EPOXY MORTAR AND GROUT THROUGHOUT
THE BUILDING.
10. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED
METAL SURFACES, OPERATING PARTS, OR LABELS.
11. HORIZONTAL WINDOW BLINDS SEGMENTS RUN
MULLION TO MULLION IN EACH EXTERIOR WINDOW
EXCEPT THE STAIRWELLS.
12. SEE SHEET I-501 FOR FLOOR FINISH DETAILS AND TILE
PATTERNS AND SHEET I-502 FOR WALL FINISH DETAILS.
13. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR
APPROVAL FROM CONTRACTING OFFICER FOR ANY
MATERIAL OR COLOR AS SHOWN ON THE PLANS AND
SPECIFICATIONS.
14. CENTER TILE PATTERNS VERTICALLY AND
HORIZONTALLY OVER TILED AREA U.O.N.
15. NO CUT TILES IN PATTERN FIELD. TRIM UNITS,
MATCHING BEADS, AND CORNER SHAPES TO BE
COORDINATED WITH FIELD TILE.
16. BULL NOSE ALL EXPOSED EDGES AND OUTSIDE
CORNERS OF CERAMIC WALL TILE AND PORCELAIN TILE
BASE.
17. FLUSH MOUNT WINDOW SILLS AT EACH WINDOW AS
DETAILED IN ARCHITECTURAL SHEETS. WINDOW SILLS
TO BE SS2.
18. ALL WALL TILE TO BE FROM TOP OF BASE TO FINISHED
CEILING.
19. ALL GWB CEILINGS TO BE PAINTED PNT1.
20. PROVIDE A CONTINUOUS POLY WATER BARRIER
MEMBRANE BEHIND CEMENT BOARD.
21. SIGNAGE, U.O.N., SHALL BE EQUAL TO
MANUFACTURER: SYSTEM 2/90 SIGN SYSTEMS,
COLLECTION: ARC - ADA COMPLIANT, BACK
PLATE/SUBSTRATE COLOR: 704 BLACK, COPY COLOR:
704 BLACK , FONT STYLE: HELVETICA, TOP/ BOTTOM
EDGE/END CAP COLOR: 704 BLACK; SIDE EDGE CAP
PROFILE: ROUND; SIDE EDGE CAP COLOR: 101 SATIN
NATURAL; PAPER INSERTS: 408 SOFT WHITE.
22. WOOD DOORS SHALL BE FACTORY FINISHED TO
MATCH MANUFACTURER: WILSONART LAMINATE,
COLOR: WILD CHERRY 754-60. ALL WOOD DOORS
SHALL BE STAINED (WS1). ALL WOOD DOORS SHALL BE
SLICED/SLIP MATCHED WOOD VENEER.
23. ELECTRICAL PANELS, ACCESS PANELS AND EXPANSION
JOINTS TO BE SPRAY PAINTED TO MATCH ADJACANT
WALL COLOR. PANELS PAINTED BY BRUSH SHALL NOT
BE ACCEPTABLE.
24. THERMOSTATS TO BE PLACED NEAR LIGHT SWITCHES.
DO NOT INSTALL IN THE CENTER OF WALLS.
25. ALL INTERIOR FINISHES MUST COMPLY WITH NFPA 101
SECTION 10.2.3.4 AND BE EITHER CLASSIFICATION A,, B,
OR C (VERIFY WITH LIFE SAFETY SHEET).
26. ALL EXTERIOR WINDOWS ON SECOND FLOOR
EXCEPT STAIRWELLS SHALL HAVE WINDOW
BLINDS(WB1) INSTALLED. NO WINDOW BLINDS ARE
REQUIRED ON THE FIRST FLOOR.
27. ALL SINKS SHALL BE INTEGRATED INTO COUNTERTOPS
AND SHALL BE CORIAN GLACIER WHITE OR EQUAL.
28. ALIGN EXPANSION JOINTS AT MORTAR JOINTS WHERE
TILE IS INSTALLED.
29. PAINT WALL LOUVERS TO MATCH ADJACENT WALL
COLOR.
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I '
D
F
IL
E N
A M
E
IS
S
U E
D A
T E
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SHEET OF
I-002
IN
T
E R
IO
R
F
IN
IS
H
L E
G E
N D
AV
IA
TI
O
N M
AI
NT
EN
AN
CE
T
RA
IN
IN
G
F
AC
IL
IT
Y F O
RT
E
US
TI
S, V
A .
N O
RF
O
LK
D
I S
TR
IC
T
NO
R F
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
J.
W
A
IN
W R
IG
H
T
J.
W
A
IN
W R
IG
H
T
D . G
E B
LE
R
J.
W
A
IN
W R
IG
H
T
JU
N
E
P
R O
JE
C
T N
O
C O
N T
R A
C T
N O
IN
T
E R
IO
R
S I-
2-
648333
FINISH LEGEND
CODE MATERIAL DESCRIPTION
ACT1 ACOUSTICAL CEILING TILE ARMSTRONG, SERIES:LYRA TEGULAR WITH PLANT BASED HIGH CAC #8731PB, COLOR:"WHITE", SIZE: 24" X 24" X 1-3/4"
AWP1 ACOUSTICAL WALL PANEL (HIGH BAY AREA) ARMSTRONG, SERIES:TECTUM DIRECT ATTACH #8181T10, COLOR:"WHITE", SIZE 24" X 96" X 1"
CPT1 CARPET TILE TANDUS, SERIES: AFTER MATH II 03026, COLOR:TAPESTRY 23512, SIZE: 24" X 24" WITH
FLEX-AIRE CUSHION MODULAR
GR1 GROUT MAPEI, SERIES: KERAPOXY CQ, COLOR: 27 SILVER
PL2 PLASTIC LAMINATE (HORIZONTAL
CASEWORK & ELEVATOR PANELS)
WILSONART, COLOR: WILD CHERRY 7054-60
PNT1 PAINT (CEILING) BENJAMIN MOORE; COLOR: CHALK WHITE 2126-70, FINISH: SATIN
PNT2 PAINT (GENERAL) SCUFFMASTER SCRUBTOUGH (WALLS) AND ARMOUR (TOILETS & STAIRS); COLOR TO
MATCH BENJAMIN MOORE DISTANT GRAY #2124-70, FINISH: SATIN
PNT3 PAINT COLOR TO MATCH BENJAMIN MOORE DISTANT GRAY #2124-70, FINISH: SEMI GLOSS
PNT4 PAINT (DOOR FRAMES) BLACK TO MATCH RB1
PT1 PORCELAIN TILE (FIELD) DAL TILE; SERIES: VERANDA SOLIDS; COLOR: SAPPHIRE P155(2); SIZE: 20X20 PT2 PORCELAIN TILE (ACCENT) DAL TILE, SERIES: VERANDA SOLIDS, COLOR: GUNMETAL P504 (1) SIZE: 20X20 PT3 PORCELAIN TILE (ACCENT) DAL TILE, SERIES: VERANDA SOLIDS, COLOR: STEEL P500 (1); SIZE: 20X20 RB1 RUBBER BASE JOHNSONITE, SERIES: TIGHT LOCK (STRAIGHT TOE) #TCBR, COLOR: BLACK, SIZE: 4-3/8" RM1 RECESSED ENTRANCE MAT CONSTRUCTION SPECIALTIES, SERIES: PEDIGRID, METAL, COLOR: MIDNIGHT CARPET
AND BLACK RUBBER INSERTS
RTF1 RUBBER SHEET FLOORING IN STAIRWELLS JOHNSONITE, SERIES:RAISED SQUARES :COLOR: GREY #48
SC SEALED CONCRETE CLEAR
SDT1 STATIC DISSIPATIVE TILE ARMSTRONG, SDT STATIC DISSIPATIVE TILE, COLOR: ARMOR GRAY 51951
SS STAINLESS STEEL (ELEVATOR INTERIOR
WALLS AND HANDRAIL)
SCHINDLER, BRUSHED STAINLESS STEEL
SS1 SOLID SURFACE (COUNTERTOPS) CORIAN, COLOR: SILVER BIRCH, FINISH: SATIN
SS2 SOLID SURFACE (WINDOW SILLS) CORIAN, COLOR: SILVER BIRCH, FINISH: SATIN
ST1 WOOD DOORS STAINED OR CLEAR COAT
STI STAIR TREAD JOHNSONITE, SERIES: TARKETT RUBBER TREAD WITH INTEGRATED RISER - SQUARE
NOSE, COLOR: GREY #48
TP1 TOILET PARTITION LAMINATING TECHNOLOGIES, SERIES: 2000, MATERIAL: SOLID PHENOLIC CORE, COLOR:
GREY PE-10; FNISH: ORANGE PEEL
VCT1 VINYL COMPOSITION TILE ARMSTRONG, MIGRATIONS BIO BASED TILE WITH BIOSTRIDE, COLOR: ASHEN GRAY T3503
VWC1 VINYL WALL COVERING WOLF GORDON; IMPACT RESISTANT WALL SOLUTIONS, COLLECTION: RAMPART, SPARTA SRP 5045 EUROTAS RIVER
WB1 WINDOW BLINDS BALI CONTRACT, HORIZONTAL ALUMINUM BLINDS, COLOR:386 SNOWCAP WHITE , SIZE:
1"
WS1 WOOD STAIN COLOR TO MATCH WILSONART LAMINATE WILD CHERRY 7054-60, CLEAR POLY FINISH
FOR DURABILITY
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
ID
7/
/2
GENERAL NOTES
1. SEE SHEET A-101 AND A-102 FOR OVERALL PLANS FOR THE
BASE BID AND SHEET A-901 FOR THE OVERALL PLAN FOR THE
BID OPTION.
2. DESIGN BASED ON SYSTEM 2/90 ARCH MODULAR SIGN
SYSTEM. "OR EQUAL" PRODUCTS WILL BE CONSIDERED.
SUBMIT SAMPLES/SHOP DRAWINGS FOR APPROVAL.
3. MECHANICALLY FASTEN GENERAL SIGNAGE TO THE WALL.
USE PRESSURE SENSITIVE TAPE WHERE MOUNTED TO
DOOR U.O.N.
4. GENERAL CONTRACTOR SHALL GENERATE AND SUBMIT
DRAWINGS, SAMPLES, AND SIGN SCHEDULE TO COR AND OWNER
FOR REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF
WORK.
5. SEE FINISH LEGEND SHEET I-002, FINISH LEGEND NOTES # 21
FOR SIGNAGE FINISH COLORS.
6. DO NOT MECHANICALLY FASTEN SIGNAGE UNITS TO
RATED AND/OR UL TESTED COMPONENTS.
7. MOUNT ROOM SIGNS PER SHEET I-310 THROUGH I-319
FOR BASE BID AND SHEET I-906 FOR BID OPTION, AS PER
INSTALLATION HEIGHTS ON SHEETS I-503 THROUGH
I-505 FOR THE BASE BID AND SHEET I-902 FOR THE BID
OPTION.
8. SUBMIT SAMPLES OF SIGNAGE AND COLORS PER
SPECIFICATIONS SECTION 10 14 00.20.
9. MOUNT EXTERIOR SIGNS WITH STAINLESS STEEL
MASONRY SLEEVE ANCHORS.
10. EXTERIOR BUILDING NUMBERS AND SIGNS ARE REQUIRED.
MOUNT WHERE INDICATED ON DRAWINGS. CONFIRM
BUILDING NUMBERS AND LOCATION WITH COR.
11. EXTERIOR SIGNAGE SHOULD BE FABRICATED WITH
NON-FERROUS MATERIALS THAT ARE WEATHER AND
UV RESISTANT. EXTERIOR SIGNAGE SHALL MATCH BASE
STANDARDS.
12. WHEN INSTALLING SIGNS ON GLASS DOORS, PLACE
SIGNS BACK TO BACK. PROVIDE A BLANK IF NO SIGN
IS REQUIRED ON BACK.
13. COORDINATE EVACUATION MAP WITH COR AND SAFETY OFFICE
PRIOR TO PRODUCTION.
14. SIGNS INDICATING CORRIDORS, LOBBY, AND ENTRANCE
VESTIBULES ARE NOT REQUIRED.
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
'D
FI
LE
N A M
E:
IS
SU
E D
AT
E:
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
SHEET OF
I-005
IN
TE
R
IO
R A
N D
E X T
ER
IO
R S
IG
N
AG
E
SC
H
E D U
LE
AV
IA
T I O
N M
AI
NT
EN
AN
CE
T
R A
IN
IN
G
F
AC
IL
IT
Y
FO
RT
E
US
TI
S, V
A.
NO
R F O
LK
D
IS
T R
IC
T
N O
RF
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
J.
W
AI
N
W R
IG
H
T
J.
W
AI
N
W R
IG
H
T
D . G
EB
LE
R
J.
W
AI
N
W R
IG
H
T
JU
N
E
PR
O
JE
C T
N O
C O
N
TR
AC
T
N O
IN
TE
R
IO
R S
I-0
648336
INTERIOR AND EXTERIOR SIGNAGE SCHEDULE
SIGN
NUM
BER
SIGN LOCATION
SIGN
TYPE
SIGN
MOUNTING
LOCATION SIGN TEXT
ROOM
NUMBER ROOM NAME
91 206 OPEN OFFICE G 4 EVACUATION MAP
92 206A CORRIDOR C 2 MECHANICAL ROOM
93 206A CORRIDOR C 2 ELECTRICAL ROOM
94 206A CORRIDOR C 2 STORAGE
95 206A CORRIDOR C 2 TELECOM ROOM
96 208 CIRCULATION E 2 RESTROOM
97 208 CIRCULATION D 2 RESTROOM
98 208 CIRCULATION C 2 RECYCLING ROOM
99 208 CIRCULATION C 2 STORAGE
100 209 WOMEN'S D 1 RESTROOM
101 209 WOMEN'S C 1 SHOWER
102 210 MEN'S E 1 RESTROOM
103 210 MEN'S C 1 SHOWER
104 213 CIRCULATION C 2 DATA CENTER
105 213 CIRCULATION C 2 COPY CENTER
106 213 CIRCULATION C 2 EMPLOYEE BREAK ROOM
107 213 CIRCULATION I 2 STAIR B
108 213 CIRCULATION A 2 OFFICE
109 213 CIRCULATION A 2 OFFICE
110 214 OPEN OFFICE C 2 ELECTRICAL ROOM
111 214 OPEN OFFICE G 4 EVACUATION MAP
112 214 OPEN OFFICE G 4 EVACUATION MAP
113 220 BREAK
ROOM
G 4 EVACUATION MAP
114 225 OPEN OFFICE C 2 TELECOM ROOM
115 225 OPEN OFFICE G 4 EVACUATION MAP
116 225 OPEN OFFICE G 4 EVACUATION MAP
117 226 CIRCULATION D 2 RESTROOM
118 226 CIRCULATION E 2 RESTROOM
119 226 CIRCULATION C 2 CONFERENCE ROOM
120 227 CONFERENCE ROOM G 4 EVACUATION MAP
121 228 MEN'S E 1 RESTROOM
122 230 WOMEN'S D 1 RESTROOM
123 231 OPEN OFFICE C 2 JANITOR CLOSET
124 231 OPEN OFFICE C 2 STORAGE
125 231 OPEN OFFICE C 2 TELECOM ROOM
126 231 OPEN OFFICE C 2 ELECTRICAL ROOM
127 231 OPEN OFFICE I 2 STAIR C
128 231 OPEN OFFICE G 4 EVACUATION MAP
129 231 OPEN OFFICE G 4 EVACUATION MAP
130 SC2 STAIR C I 2 FLOOR 2
131 SA1 STAIR A I 2 FLOOR 1
132 130 MEN'S E 1 RESTROOM
133 SC1 STAIR C I 2 FLOOR 1
134 E3 5 (NO SMOKING STATEMENT)
135 E1 5 AUTHORIZED PERSONNEL ONLY - ELECTRICAL
ROOM
136 E1 5 AUTHORIZED PERSONNEL ONLY - FIRE PUMP ROOM
137 E1 5 AUTHORIZED PERSONNEL ONLY - ELECTRICAL
ROOM
138 E1 5 AUTHORIZED PERSONNEL ONLY - MAIN ELECTRICAL
ROOM
139 E1 5 AUTHORIZED PERSONNEL ONLY - MECHANICAL
ROOM
140 E1 5 AUTHORIZED PERSONNEL ONLY - MECHANICAL
YARD
141 E1 5 AUTHORIZED PERSONNEL ONLY - MECHANICAL
YARD
142 E3 5 (NO SMOKING STATEMENT)
143 E3 5 (NO SMOKING STATEMENT)
144 E3 5 (NO SMOKING STATEMENT)
145 E3 5 (NO SMOKING STATEMENT)
146 E3 5 (NO SMOKING STATEMENT)
147 E3 5 (NO SMOKING STATEMENT)
148 E3 5
149 E3 5 (NO SMOKING STATEMENT)
150 E3 5 (NO SMOKING STATEMENT)
151 E1 5 AUTHORIZED PERSONNEL ONLY - STORAGE
152 230 WOMEN'S C 1 SHOWER
153 228 MEN'S C 1 SHOWER
154 135 HIGH BAY TRAINING G 2 EVACUATION MAP
155 135 HIGH BAY TRAINING F 2 (OCCUPANCY STATEMENT)
156 135 HIGH BAY TRAINING F 2 (OCCUPANCY STATEMENT)
157 135 HIGH BAY TRAINING G 2 EVACUATION MAP
158 135 HIGH BAY TRAINING F 2 (OCCUPANCY STATEMENT)
159 135 HIGH BAY TRAINING G 2 EVACUATION MAP
161 F 2 (OCCUPANCY STATEMENT)
162 G 2 EVACUATION MAP
164 135 HIGH BAY TRAINING F 2 (OCCUPANCY STATEMENT)
165 135 HIGH BAY TRAINING G 2 EVACUATION MAP
166 101 CIRCULATION K 5 1
167 101 CIRCULATION K 5 1
168 101 CIRCULATION L 4 (ELEVATOR EGRESS)
169 213 CIRCULATION L 4 (ELEVATOR EGRESS)
170 213 CIRCULATION K 5 2
171 213 CIRCULATION K 5 2
172 101 CIRCULATION H 4 DIRECTIONAL SIGN
173 213 CIRCULATION H 4 DIRECTIONAL SIGN
INTERIOR AND EXTERIOR SIGNAGE SCHEDULE
SIGN
NUM
BER
SIGN LOCATION
SIGN
TYPE
SIGN
MOUNTING
LOCATION SIGN TEXT
ROOM
NUMBER ROOM NAME
1 101 CIRCULATION E 2 RESTROOM
2 101 CIRCULATION D 2 RESTROOM
3 101 CIRCULATION D 2 RESTROOM
4 101 CIRCULATION E 2 RESTROOM
5 101 CIRCULATION C 2 TELECOM ROOM
6 101 CIRCULATION I 2 STAIR C
7 101 CIRCULATION C 2 TELECOM ROOM
8 101 CIRCULATION C 2 JANITOR CLOSET
9 101 CIRCULATION C 2 ELEVATOR MECHANICAL ROOM
10 101 CIRCULATION C 2 COMPUTER MAINTENANCE ROOM
11 101 CIRCULATION C 2 ELECTICAL ROOM
12 101 CIRCULATION I 2 STAIR A
13 101 CIRCULATION C 2 TEF ROOM
14 101 CIRCULATION B 4 CLASSROOM #10
15 101 CIRCULATION B 4 CLASSROOM #9
16 101 CIRCULATION B 4 CLASSROOM #8
17 101 CIRCULATION B 4 CLASSROOM #7
18 101 CIRCULATION B 4 CLASSROOM #6
19 101 CIRCULATION C 2 RECYCLING ROOM
20 101 CIRCULATION C 2 STUDENT BREAKROOM
21 101 CIRCULATION B 4 CLASSROOM #5
22 101 CIRCULATION B 4 CLASSROOM #4
23 101 CIRCULATION B 4 CLASSROOM #3
24 101 CIRCULATION B 4 CLASSROOM #2
25 101 CIRCULATION B 4 CLASSROOM #1
26 101A LOBBY F 4 (OCCUPANCY STATEMENT)
27 101A LOBBY G 4 EVACUATION MAP
28 101A LOBBY M 4 (DIRECTORY DESIGN)
29 106 CLASSROOM #01 G 4 EVACUATION MAP
30 107 CLASSROOM #02 G 4 EVACUATION MAP
31 108 CLASSROOM #03 G 4 EVACUATION MAP
32 109 WOMEN'S D 1 RESTROOM
33 110 MEN'S E 1 RESTROOM
34 111 CLASSROOM #04 G 4 EVACUATION MAP
35 112 CLASSROOM #05 G 4 EVACUATION MAP
36 114 COMPUTER
MAINTENANCE
G 4 EVACUATION MAP
37 115 BREAK ROOM G 4 EVACUATION MAP
38 116 BREAK AREA G 4 EVACUATION MAP
39 101A LOBBY I 2 STAIR B
40 120 CLASSROOM #06 G 4 EVACUATION MAP
41 121 CLASSROOM #07 G 4 EVACUATION MAP
42 123 WOMEN'S D 1 RESTROOM
43 124 MEN'S E 1 RESTROOM
44 125 CLASSROOM #08 G 4 EVACUATION MAP
45 126 CLASSROOM #09 G 4 EVACUATION MAP
46 127 CLASSROOM #10 G 4 EVACUATION MAP
47 131 WOMEN'S D 1 RESTROOM
48 133 WOMEN'S D 1 RESTROOM
49 134 MEN'S E 1 RESTROOM
50 135 HIGH BAY TRAINING E 2 RESTROOM
51 135 HIGH BAY TRAINING D 2 RESTROOM
52 135 HIGH BAY TRAINING E 2 RESTROOM
53 135 HIGH BAY TRAINING D 2 RESTROOM
54 135 HIGH BAY TRAINING C 2 MECHANICAL ROOM
55 135 HIGH BAY TRAINING B 4 CLASSROOM #8
56 135 HIGH BAY TRAINING B 4 CLASSROOM #9
57 135 HIGH BAY TRAINING B 4 CLASSROOM #10
58 135 HIGH BAY TRAINING B 4 CLASSROOM #7
59 135 HIGH BAY TRAINING B 4 CLASSROOM #6
60 135 HIGH BAY TRAINING C 2 MAIN INSTRUCTIONAL BUILDING
61 135 HIGH BAY TRAINING C 2 TOOL STORAGE AND ISSUE
62 135 HIGH BAY TRAINING C 2 TOOL STORAGE AND ISSUE
63 135 HIGH BAY TRAINING B 4 CLASSEOOM #5
64 135 HIGH BAY TRAINING B 4 CLASSROOM #4
65 135 HIGH BAY TRAINING B 4 CLASSROOM #3
66 135 HIGH BAY TRAINING B 4 CLASSROOM #2
67 135 HIGH BAY TRAINING B 4 CLASSROOM #1
68 206 OPEN OFFICE I 2 STAIR A
69 SB1 STAIR B I 2 FLOOR 1
71 SA2 STAIR A F 4 (OCCUPANCY STATEMENT)
72 101 CIRCULATION C 2 STUDENT BREAKROOM
73 SB2 STAIR B I 2 FLOOR 2
82 200 LOBBY C 2 STORAGE
83 200 LOBBY A 2 CO
84 200 LOBBY A 2 1 SG
85 200 LOBBY A 2 OPS
86 200 LOBBY A 2 XO
87 200 LOBBY G 4 EVACUATION MAP
89 206 OPEN OFFICE C 2 JANITOR'S CLOSET
90 206 OPEN OFFICE G 4 EVACUATION MAP
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ID
/2
4/
BASE BID AND SHEET A-901 FOR THE OVERALL PLAN FOR THE
BID OPTION.
2. DESIGN BASED ON SYSTEM 2/90 ARCH MODULAR SIGN
SYSTEM. "OR EQUAL" PRODUCTS WILL BE CONSIDERED.
SUBMIT SAMPLES/SHOP DRAWINGS FOR APPROVAL.
3. MECHANICALLY FASTEN GENERAL SIGNAGE TO THE WALL.
USE PRESSURE SENSITIVE TAPE WHERE MOUNTED TO
DOOR U.O.N.
4. GENERAL CONTRACTOR SHALL GENERATE AND SUBMIT
DRAWINGS, SAMPLES, AND SIGN SCHEDULE TO COR AND OWNER
FOR REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF
WORK.
5. SEE FINISH LEGEND SHEET I-002, FINISH LEGEND NOTES # 21
FOR SIGNAGE FINISH COLORS.
6. DO NOT MECHANICALLY FASTEN SIGNAGE UNITS TO
RATED AND/OR UL TESTED COMPONENTS.
7. MOUNT ROOM SIGNS PER SHEET I-310 THROUGH I-319
FOR BASE BID AND SHEET I-906 FOR BID OPTION, AS PER
INSTALLATION HEIGHTS ON SHEETS I-503 THROUGH
I-505 FOR THE BASE BID AND SHEET I-902 FOR THE BID
OPTION.
8. SUBMIT SAMPLES OF SIGNAGE AND COLORS PER
SPECIFICATIONS SECTION 10 14 00.20.
9. MOUNT EXTERIOR SIGNS WITH STAINLESS STEEL
MASONRY SLEEVE ANCHORS.
10. EXTERIOR BUILDING NUMBERS AND SIGNS ARE REQUIRED.
MOUNT WHERE INDICATED ON DRAWINGS. CONFIRM
BUILDING NUMBERS AND LOCATION WITH COR.
11. EXTERIOR SIGNAGE SHOULD BE FABRICATED WITH
NON-FERROUS MATERIALS THAT ARE WEATHER AND
UV RESISTANT. EXTERIOR SIGNAGE SHALL MATCH BASE
STANDARDS.
12. WHEN INSTALLING SIGNS ON GLASS DOORS, PLACE
SIGNS BACK TO BACK. PROVIDE A BLANK IF NO SIGN
IS REQUIRED ON BACK.
13. COORDINATE EVACUATION MAP WITH COR AND SAFETY OFFICE
PRIOR TO PRODUCTION.
14. SIGNS INDICATING CORRIDORS, LOBBY, AND ENTRANCE
VESTIBULES ARE NOT REQUIRED.
A-
A-
A-
A-
CLASSROOM #06
CLASSROOM #05
CLASSROOM #04
COMPUTER
MAINTENANCE
BREAK ROOM
ELEC IDF
TOOL
STORAGE/ISSUE
CIRCULATION
BREAK AREA
HIGH BAY
TRAINING
TELCOM IDF
JAN
RECYCLING
ELEV
EA1
ELEV MECH
WOMEN'S
VEST
51 D 48D
26F
27G
E3
G
G
G
G
G
G
7 C
8 C
C
C
11C
C
61C62 C
C
C
SB1
101A
B
B
B
B
B
B
28M
I
69I
C
G
F
K
K
L
H
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
'D
FI
LE
N A M
E:
IS
SU
E D
AT
E:
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
SHEET OF
I-311
FI
R
ST
F
L O O
R S
IG
N
A G E
PL
AC
EM
EN
T
PL
AN
AR
EA
B
AV
IA
T I O
N M
AI
NT
EN
AN
CE
T
R A
IN
IN
G
F
AC
IL
IT
Y
FO
RT
E
US
TI
S, V
A.
NO
R F O
LK
D
IS
T R
IC
T
N O
RF
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
J.
W
AI
N
W R
IG
H
T
J.
W
AI
N
W R
IG
H
T
D . G
EB
LE
R
J.
W
AI
N
W R
IG
H
T
JU
N
E
PR
O
JE
C T
N O
C O
N
TR
AC
T
N O
IN
TE
R
IO
R S
I-3
648361
N
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
SCALE: NTS
KEY PLAN
'C' 'B' 'A'
'F' 'E' 'D''G'
SCALE: 1/8" = 1'-0"
FIRST FLOOR SIGNAGE PLACEMENT PLAN - AREA B
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ID
/2
4/
BASE BID AND SHEET A-901 FOR THE OVERALL PLAN FOR THE
BID OPTION.
2. DESIGN BASED ON SYSTEM 2/90 ARCH MODULAR SIGN
SYSTEM. "OR EQUAL" PRODUCTS WILL BE CONSIDERED.
SUBMIT SAMPLES/SHOP DRAWINGS FOR APPROVAL.
3. MECHANICALLY FASTEN GENERAL SIGNAGE TO THE WALL.
USE PRESSURE SENSITIVE TAPE WHERE MOUNTED TO
DOOR U.O.N.
4. GENERAL CONTRACTOR SHALL GENERATE AND SUBMIT
DRAWINGS, SAMPLES, AND SIGN SCHEDULE TO COR AND OWNER
FOR REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF
WORK.
5. SEE FINISH LEGEND SHEET I-002, FINISH LEGEND NOTES # 21
FOR SIGNAGE FINISH COLORS.
6. DO NOT MECHANICALLY FASTEN SIGNAGE UNITS TO
RATED AND/OR UL TESTED COMPONENTS.
7. MOUNT ROOM SIGNS PER SHEET I-310 THROUGH I-319
FOR BASE BID AND SHEET I-906 FOR BID OPTION, AS PER
INSTALLATION HEIGHTS ON SHEETS I-503 THROUGH
I-505 FOR THE BASE BID AND SHEET I-902 FOR THE BID
OPTION.
8. SUBMIT SAMPLES OF SIGNAGE AND COLORS PER
SPECIFICATIONS SECTION 10 14 00.20.
9. MOUNT EXTERIOR SIGNS WITH STAINLESS STEEL
MASONRY SLEEVE ANCHORS.
10. EXTERIOR BUILDING NUMBERS AND SIGNS ARE REQUIRED.
MOUNT WHERE INDICATED ON DRAWINGS. CONFIRM
BUILDING NUMBERS AND LOCATION WITH COR.
11. EXTERIOR SIGNAGE SHOULD BE FABRICATED WITH
NON-FERROUS MATERIALS THAT ARE WEATHER AND
UV RESISTANT. EXTERIOR SIGNAGE SHALL MATCH BASE
STANDARDS.
12. WHEN INSTALLING SIGNS ON GLASS DOORS, PLACE
SIGNS BACK TO BACK. PROVIDE A BLANK IF NO SIGN
IS REQUIRED ON BACK.
13. COORDINATE EVACUATION MAP WITH COR AND SAFETY OFFICE
PRIOR TO PRODUCTION.
14. SIGNS INDICATING CORRIDORS, LOBBY, AND ENTRANCE
VESTIBULES ARE NOT REQUIRED.
OPEN OFFICE
STORAGE
RECYCLING
OPS
STAIR B
SB2
CIRCULATION
DATA CENTER
LOBBY
CIRCULATION
CO
OPEN OFFICE
XO
1SG
OFF
ELEC
OFF
TR
BREAK
ROOM
ELEV
EA2
A-
A-
A-
A-
C
110C
E
C
C
C
C
114 C
82 C
A
86A
83A A
A
A
G
87 G
G
G
112 G
I
73 I
L
K
K
H
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
'D
FI
LE
N A M
E:
IS
SU
E D
AT
E:
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
SHEET OF
I-318
SE
C
O N
D F
LO
O
R S
IG
N
AG
E
PL
AC
EM
EN
T
PL
AN
AR
EA
B
AV
IA
T I O
N M
AI
NT
EN
AN
CE
T
R A
IN
IN
G
F
AC
IL
IT
Y
FO
RT
E
US
TI
S, V
A.
NO
R F O
LK
D
IS
T R
IC
T
N O
RF
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
J.
W
AI
N
W R
IG
H
T
J.
W
AI
N
W R
IG
H
T
D . G
EB
LE
R
J.
W
AI
N
W R
IG
H
T
JU
N
E
PR
O
JE
C T
N O
C O
N
TR
AC
T
N O
IN
TE
R
IO
R S
I-3
648368
N
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
SCALE: NTS
KEY PLAN
'C' 'B' 'A'
'F' 'E' 'D''G'
SCALE: 1/8" = 1'-0"
SECOND FLOOR SIGNAGE PLACEMENT PLAN - AREA B
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ID
/2
4/
BASE BID AND SHEET A-901 FOR THE OVERALL PLAN FOR THE
BID OPTION.
2. DESIGN BASED ON SYSTEM 2/90 ARCH MODULAR SIGN
SYSTEM. "OR EQUAL" PRODUCTS WILL BE CONSIDERED.
SUBMIT SAMPLES/SHOP DRAWINGS FOR APPROVAL.
3. MECHANICALLY FASTEN GENERAL SIGNAGE TO THE WALL.
USE PRESSURE SENSITIVE TAPE WHERE MOUNTED TO
DOOR U.O.N.
4. GENERAL CONTRACTOR SHALL GENERATE AND SUBMIT
DRAWINGS, SAMPLES, AND SIGN SCHEDULE TO COR AND OWNER
FOR REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF
WORK.
5. SEE FINISH LEGEND SHEET I-002, FINISH LEGEND NOTES # 21
FOR SIGNAGE FINISH COLORS.
6. DO NOT MECHANICALLY FASTEN SIGNAGE UNITS TO
RATED AND/OR UL TESTED COMPONENTS.
7. MOUNT ROOM SIGNS PER SHEET I-310 THROUGH I-319
FOR BASE BID AND SHEET I-906 FOR BID OPTION, AS PER
INSTALLATION HEIGHTS ON SHEETS I-503 THROUGH
I-505 FOR THE BASE BID AND SHEET I-902 FOR THE BID
OPTION.
8. SUBMIT SAMPLES OF SIGNAGE AND COLORS PER
SPECIFICATIONS SECTION 10 14 00.20.
9. MOUNT EXTERIOR SIGNS WITH STAINLESS STEEL
MASONRY SLEEVE ANCHORS.
10. EXTERIOR BUILDING NUMBERS AND SIGNS ARE REQUIRED.
MOUNT WHERE INDICATED ON DRAWINGS. CONFIRM
BUILDING NUMBERS AND LOCATION WITH COR.
11. EXTERIOR SIGNAGE SHOULD BE FABRICATED WITH
NON-FERROUS MATERIALS THAT ARE WEATHER AND
UV RESISTANT. EXTERIOR SIGNAGE SHALL MATCH BASE
STANDARDS.
12. WHEN INSTALLING SIGNS ON GLASS DOORS, PLACE
SIGNS BACK TO BACK. PROVIDE A BLANK IF NO SIGN
IS REQUIRED ON BACK.
13. COORDINATE EVACUATION MAP WITH COR AND SAFETY OFFICE
PRIOR TO PRODUCTION.
14. SIGNS INDICATING CORRIDORS, LOBBY, AND ENTRANCE
VESTIBULES ARE NOT REQUIRED.
FINISHED
FLOOR
5'
- 0
" A
FF
3"
LOCATION 2 LOCATION 3 LOCATION 4LOCATION 1
5'
- 0
" A
FF
5'
- 0
" A
FF
ELEVATOR LOCATION
5'
- 0
" A
FF
5"
9"
TYPE B - CLASSROOM WITH 8.5"X11" INSERT
TYPE F - INTERIOR OCCUPANCY
MAXIMUM
OCCUPANCY
NOT TO EXCEED
# PERSONS
BRAILLE
1/2" HIGH
ADA
TACTILE
COPY
SLIMLINE ENDCAPS
CLASSROOM
2" HIGH
ADA
TACTILE
COPY
SLIMLINE ENDCAPS
8.5" X 11" CLEAR
INSERT WITH
COPY TO BE
PROVIDED BY
GOVERNMENT
END USER
TYPE C - PERMANENT ROOM IDENTIFICATION SIGNTYPE A - ROOM IDENTIFICATION SIGN
OPTIONAL 1 1/2 TACILE
ROOM NUMBER WITH
BRAILLE HELVETICA NEUE
ROMAN
6" SYMBOL
1" TACILE ROOM
DESCRIPTION WITH
BRAILLE
HELVETICA NEUE 55 ROMAN
TYPE D&E - RESTROOM IDENTIFICATION SIGN
OPTIONAL 1 1/2 TACILE
ROOM NUMBER WITH
BRAILLE HELVETICA NEUE
ROMAN
6" SYMBOL
1" TACILE ROOM
DESCRIPTION WITH
BRAILLE
HELVETICA NEUE 55 ROMAN
TYPE I - STAIR IDENTIFICATION SIGN
5/8" MESSAGE
TEXT
HELVETICA
NEUE 55 ROMAN
REPLACEABLE
EVACUATION
MAP
TYPE L - ELEVATOR EGRESS SIGN
2" TACTILE LEVEL
DESIGNATION WITH
BRAILLE
2" TACTILE LEVEL
DESIGNATION WITH
BRAILLE
TYPE K - ELEVATOR HOIST WAY LEVEL INDICATORS
3" MESSAGE INSERT
PANELS WITH 1 1/2
ARROWS AND 1"
MESSAGE TEXT
HELVETICA NEUE 65
MEDIUM
TYPE H - WALL MOUNTED DIRECTIONAL SIGN
1 1/2" TACTILE ROOM
NUMBER WITH BRAILLE
3/4" PRINTED
MESSAGE
HELVETICA
NEUE 55 ROMAN
REMOVABLE END CAPS
1 1/2" TACTILE ROOM
NUMBER WITH BRAILLE
3/4" PRINTED
MESSAGE
HELVETICA
NEUE 55 ROMAN
PRINTED PAPER INSERT
WITH ROOM
DESCRIPTION
REMOVABLE END CAPS
BROWN BACKGROUND
WITH
WHITE LETTERS
EMERGENCY
SHUTDOWN OF
OUTSIDE PUSH
BUTTON. PUSH TO
ACTIVATE. RED
LIGHT FLASHES IN
ACTIVATED STATE.
PULL TO
DE-ACTIVATE.
COORDINATE
INSTALLATION
LOCATION WITH COR AND
SHUT OFF BUTTON
TYPE J - EMERGENCY SHUT OFF BUTTON
EVACUATION MAP
1" HIGH TEXT
1/2" BORDER
CONTRACTOR TO
PROVIDE MAP IN
ACCORDANCE
WITH
NFPA 101
TYPE G - EVACUATION MAP
8"
8" 1' - 0"
1'
6"
9"
9"
3" 6"
9"
9"
3" 6"
9"
1'
2"
3" 8"
3"
8 1/2"
9"
1'
1/
2"
3"
1/ 2"
2"
8 1/2"
1'
6"
1' - 0"
11 1/2"
3 1/2"
3"
3"
3"
2'
6"
1' - 8"
1' - 0"
1'
0"
1' - 8"
1'
4"
TYPE M- BUILDING DIRECTORY
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K E
D B
Y:
AN
SI
'D
FI
LE
N A M
E:
IS
SU
E D
AT
E:
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
SHEET OF
I-503
IN
TE
R
IO
R S
IG
N
AG
E
D
ET
AI
LS
AV
IA
T I O
N M
AI
NT
EN
AN
CE
T
R A
IN
IN
G
F
AC
IL
IT
Y
FO
RT
E
US
TI
S, V
A.
NO
R F O
LK
D
IS
T R
IC
T
N O
RF
O
LK
, V A.
RT
A
SU
BM
IT
TA
L
J.
W
AI
N
W R
IG
H
T
J.
W
AI
N
W R
IG
H
T
D . G
EB
LE
R
J.
W
AI
N
W R
IG
H
T
JU
N
E
PR
O
JE
C T
N O
C O
N
TR
AC
T
N O
IN
TE
R
IO
R S
I-5
648371
SCALE: NTS
INTERIOR SIGNAGE LOCATIONS
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ID
/2
4/
SCALE: NTS
SIGNS
| SUMMARY OF CHANGES |
| Combined Spec Changes |
| S 7577172 - 07 42 63 Revised Spec |
| S 7574875 - 07 61 1400 20 Revised Spec |
| S 7575671 - 08 34 1610 Revised Spec |
| S 7578276 - 09 90 00 Revised Specification Paints and Coatings |
| Combined Drawing Changes |
| D 7578173 - CD904 Revised Drawing |
| Sheets and Views |
| CD904 |
| D 7579844 - S-003 Revised Drawing |
| D 7577169 - A-501 Revised Drawing |
| D 7574831 - A-631 Revised Drawing |
| D 7578280 - I-002 Revised Drawing Interior Finish Legend |
| D 7574934 - I-005 Revised Drawing Revised Interior and Exterior Signage Schedule |
| D 7574934 - I-311 Revised Drawing Signage First Floor |
| D 7574934 - I-318 Revised Drawing Signage Second Floor |
| D 7574934 - I-503 Revised Drawing Signage Details |
File details come from the government source that posted it.