SKETCHES AND REFERENCE DRAWINGS
AMENDMENT 0001
'-0
±1 0'-
0"
10'-0"
0 8' 32'16'
SCALE: 1/16"=1'
LOCK
ROAD TO
BRIDGE
ROUTE 837
ROUTE 837FENCE
EXISTING
OFFICE SITE PLAN
SCALE: 1/16"=1'-0"
LOT
PARKING
ASPHALT
N
SEE SK-03
EXISTING OFFICE BLDG
SEE SK-02
BLDG
NEW OFFICE
INTERNET CONDUIT RACK
EXISTING ELECTRICAL
LIMITS
CONTRACTOR WORK
SEE SK-02
STRUCTURE
BREEZEWAY
NEW ELEVATED
INTERCEPTOR (TYP)
MANHOLE AND GRAVITY
EXISTING MUNICIPAL SEWER
WIRE ACCESS POINT
LINE VALVE AND TRACER
EXISTING WATER SERVICE
LOCATION
DUMPSTER
PROPOSED(APPROXIMATE)
PROPERTY LINE
(MIN)
NOTES:
ABBREVIATIONS
TYPICALTYP
TOPT/
SCHEDULESCH
POLYVINYL CHLORIDEPVC
MINIMUMMIN
HEATING, VENTILATION AND AIR CONDITIONERHVAC
FEETFT
EXISTINGEXIST
ETHYLENE PROPYLENE DIENE TEROPOLYMEREPDM
ELEVATIONELEV
DIAMETERDIA
BUILDINGBLDG
APPROXIAMTEAPPROX
AIR CONDITIONERA/C
LEGEND
CONTRACTOR WORK LIMITS
PL PROPERTY LINE
X FENCE LINE
W X EXITING WATER LINE
G X EXITING GAS LINE
SS X EXITING SANITARY SEWER
GRADING IMPROVEMENT AREA
DUMPSTER LOCATION
DUMPSTER TO PROPOSED
RELOCATE EXISTING
SURFACING PER SPECIFICATION
FURNISH AND PLACE NEW ASPHALT
TO DRAIN AWAY FROM STRUCTURE.
AND GRADE AS NECESSARY
ASPHALT. FURNISH, IMPORT FILL
REMOVE AND DISPOSE OF EXIST
GRADING IMPROVEMENT AREA
EXISTING ELECTRICAL PANELS
OF WATER TIE-IN.
APPROX LOCATION
SERVICE.
OF EXISTING SEWER
APPROX LOCATION
ENTRANCE GATE.
EXISTING SLIDING
STORAGE TANKS
UNDERGROUND
EXISTING ABANDONED
APPROX LOCATION OF
SPECIFICATIONS.
ACCORDANCE WITH SECTION 01 11 00 OF THE TECHNICAL
2. CONDUCT ALL SITE UTILITY INVESTIGATION WORK IN
WITH FINAL APPROVAL BY THE CONTRACTING OFFICER.
AND LAYOUT OF ALL IMPROVEMENTS AND MODIFICATIONS
ONLY. CONTRACTOR IS RESPONSIBLE FOR COORDINATION
1. THIS SKETCH IS PROVIDED FOR ILLUSTRATION PURPOSES
SK-01
S
IT
E P
L A
N
R T
Y S
Z K
IE
W
IC
Z
J
U S
N A
K
C M
A R
T
IN
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
IS
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
08-JA
N-20
19 08 :43
P
IT
T S
B U
R G
H D
IS
T R
IC
T
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
P L
O T D
A T
E
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
L O
W E
R M
O
L
W E
R M
O N A
R E
A O
F F
IC
E R
E H
B
60' 0"
SK-02
E
W B
U
IL
D
IN
G L
A Y
O U
0 4' 8'2'
SCALE: 1/4"=1'
~ 30'x28'
CONFERENCE ROOM
~ 12'x12'
OFFICE
~ 12'x12'
OFFICE
4' WIDE HALLWAY
~ 6'x12'
ROOM
UTILITY
~11'x12'
OFFICE
~11'x12'
OFFICE
(4 TYP)
EXTERIOR LIGHT
(14 TYP)
WINDOWS
BUILDING
OFFICE
TO EXISTING
AND PLATFORM
NEW STEPS
STRUCTURE.
BREEZEWAY
NEW ELEVATED
FRONT OF BUILDING
REAR OF BUILDING
N
R T
Y S
Z K
IE
W
IC
Z
NOTES:
PROPOSED NEW OFFICE BUILDING LAYOUT
1/4"=1'-0"
OFFICE BUILDING)
(FROM EXISTING
AND PLATFORM
RELOCATED STEPS
~7'x12'
RESTROOM
WOMENS
TO THE NEW LIGHTING PANELS
IN THE TRAILERS CRAWL SPACE
CONDUIT SHALL BE ROUTED
SHALL BE INSTALLED
CONDUIT EXPANSION FITTINGS
PLATFORM
STEPS AND
DOOR, ALUMINUM
SECONDARY EXIT
J R
U S
N A
K
C M
A R
T
IN
4. FOR LIST OF ABBREVIATIONS SEE SKETCH SK-01.
OFFICE BUILDINGS WITTHIN +/- ¼ INCH.
ELEVATION OF THE CONNECTED NEW OFFICE AND EXISTING
3. BREEZEWAY FINISHED FLOOR ELEVATION SHALL MATCH
OFFICE BUILDING.
STYLE AND PITCH AS THAT OF NEW ROOF FOR EXISTING
2. NEW BUILDING AND BREEZEWAY ROOFS SHALL BE SAME
WITH FINAL APPROVAL BY THE CONTRACTING OFFICER.
AND LAYOUT OF ALL IMPROVEMENTS AND MODIFICATIONS
ONLY. CONTRACTOR IS RESPONSIBLE FOR COORDINATION
1. THIS SKETCH IS PROVIDED FOR ILLUSTRATION PURPOSES
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
IS
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
-J
A N -2
:4
P
IT
T S
B U
R G
H D
IS
T R
IC
T
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
P L
O T D
A T
E
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
L O
W E
R M
W E
R M
O N A
R E
A O
F F
IC
E R
E H
76'-0"
0 4' 8'2'
SCALE: 1/4"=1'
SK-03
DOOR
REMOVE
A
SK-04
ADD NEW DOOR
RESTROOM
NEW OFFICE BLDG
RESTROOM SIGN TO
RELOCATE WOMENS
TOILETS
EXISTING
REPLACE
BEYOND FENCE
DISCHARGE
DRAIN LINE TO
CONDENSATION
NEW HVAC UNIT
EQUAL SIZED ROOMS ~ 15'x11'
ADD WALL TO CREATE 2
CIRCUITS
INTO 2 INDEPENDENT
SEPARATE LIGHTING
ONE WAY SWITCHES,
3-WAY SWITCHES WITH
REPLACE EXISTING
S
S
VESTIBULE.
EXISTING ENTRANCE
REMOVE AND DISPOSE OF
SIDE OF THE BUILDING.
STAIRS LOCATED ON OPPOSITE
SHALL BE SIMILAR TO EXISTING
AND HAND RAILS. NEW STAIRS
ALUMINUM STAIRS W/PLATFORM
FURNISH AND INSTALL NEW
E X
IS
T
IN
G B
U
IL
D
IN
G M
O D
IF
IC
A T
IO
N S
BUILDING
OFFICE
TO NEW
N
SEE SKETCH SK-02
STRUCTURE.
BREEZEWAY
NEW ELEVATED
NEW ORIENTATION.
CONFIGURATION TO ACCOMMODATE
FRONT ENTRANCE. MODIFY HAND RAIL
TO NEW BREEZEWAY STRUCTURE
RELOCATE EXISTING STEPS
R T
Y S
Z K
IE
W
IC
Z
NOTES:
A/C UNIT
MOUNTED
ELEVATED, WALL
A/C UNIT
MOUNTED
ELEVATED, WALL
A/C UNIT
MOUNTED
ELEVATED, WALL
RENOVATED EXISTING OFFICE BUILDING
1/4"=1'-0"
OFFICE OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
COMMUNICATIONS
OFFICE
OFFICE
FOYER
NEW BREEZEWAY
AREA
BREAK
CONDUIT SEE SK-02
FOR CONTINUATION OF
BE FIELD DETERMINED
AND CONDUIT SUPPORTS SHALL
EXACT LOCATION OF NEW CONDUIT
NEW POWER CONDUIT
EXISTING COMMUNICATION CONDUIT
COMMUNICATIONS ROOM
ETHERNET SWITCH IN THE
CABLES TO THE EXISTING
COMMUNICATION
NEW CONDUIT FOR
(TYPICAL 6 LOCATIONS)
LIGHT FIXTURES
REPLACE EXISTING
SUPPORT DETAILS.
CONDUIT AND CONDUIT
DRAWINGS FOR EXISTING
SEE EXISTING REFERENCE
J R
U S
N A
K
C M
A R
T
IN
6. FOR LIST OF ABBREVIATIONS SEE SKETCH SK-01.
AND DETAIL.
5. SEE SKETCH SK-04 FOR TYPICAL NEW ROOF SECTION
BY CONTRACTING OFFICER.
PENETRATION LOCATION CHANGES MUST BE APPROVED
BE EXTENDED THROUGH NEW ROOF. ANY ROOF
4. EXISTING ROOF PENETRATION LOCATIONS SHALL
SPECIFICATIONS.
WITH SECTION 01 11 00 OF THE TECHNICAL
3. ALL RENOVATION WORK TO BE IN ACCORDANCE
PROTECTED DURING ALL PHASES OF WORK.
2. EXISTING BUILDING IS TO BE KEPT IN USE AND
APPROVAL BY THE CONTRACTING OFFICER.
IMPROVEMENTS AND MODIFICATIONS WITH FINAL
FOR COORDINATION AND LAYOUT OF ALL
PURPOSES ONLY. CONTRACTOR IS RESPONSIBLE
1. THIS SKETCH IS PROVIDED FOR ILLUSTRATION
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
IS
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
-J
A N -2
:4
P
IT
T S
B U
R G
H D
IS
T R
IC
T
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
P L
O T D
A T
E
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
L O
W E
R M
W E
R M
O N A
R E
A O
F F
IC
E R
E H
±41'-6"
SEE NOTE 5
SK-04
X
IS
T
IN
G B
U
IL
D
IN
G M
O D
IF
IC
A T
IO
N S
S E
C T
IO
N S A
N D D
E T
A
IL
S
WINDOW
EXIST
WINDOW
EXIST
WINDOW
EXIST
A
SK-03
SECTION
1/4"=1'-0"
IF NECESSARY
WINDOW MAY BE REMOVED
SKIRTING
T/ASPHALT
BLDG FLOOR ELEV
NEW ROOF
0 4' 8'2'
SCALE: 1/4"=1'
SLOPE
(TYP 3 LOCATIONS)
PLASTIC TUBING
NEW CLEAR
SLOPE MIN 1/4"/FT
DRAIN MOUNTED TO SKIRTING
PIPE HVAC CONDENSATE
NEW 1" DIA SCH 40 PVC
PVC PIPING (TYP)
CONNECT TUBING TO
R T
Y S
Z K
IE
W
IC
Z
5. DECKING
4. INSULATION
3. COVER BOARD
2. BONDING
1. EPDM MEMBRANE
OUTERMOST FIRST-
ROOFING LAYERS
UNIT
A/C
EXIST
UNIT
A/C
EXIST
UNIT
A/C
EXIST
NOTE:
PROVIDED BY CONTRACTOR
NEW DOOR DETAILS TO BE
BREEZEWAY DOOR.
PROPOSED LOCATION FOR
J R
U S
N A
K
C M
A R
T
IN
6. FOR LIST OF ABBREVIATIONS SEE SKETCH SK-01.
BY CONTRACTOR AND APPROVED BY CONTRACTING OFFICER.
5. ROOF TRANSITIONS BETWEEN BUILDINGS TO BE DETERMINED
OFFICER.
LOCATION CHANGES MUST BE APPROVED BY CONTRACTING
EXTENDED THROUGH NEW ROOF. ANY ROOF PENETRATION
4. EXISTING ROOF PENETRATION LOCATIONS SHALL BE
SECTION 01 11 00 OF THE TECHNICAL SPECIFICATIONS.
3. ALL RENOVATION WORK TO BE IN ACCORDANCE WITH
DURING ALL PHASES OF WORK.
2. EXISTING BUILDING IS TO BE KEPT IN USE AND PROTECTED
WITH FINAL APPROVAL BY THE CONTRACTING OFFICER.
AND LAYOUT OF ALL IMPROVEMENTS AND MODIFICATIONS
ONLY. CONTRACTOR IS RESPONSIBLE FOR COORDINATION
1. THIS SKETCH IS PROVIDED FOR ILLUSTRATION PURPOSES
TYPICAL ROOF DETAIL
1/4"=1'-0"
NEW ELEVATED BREEZEWAY
APPROX LOCATION OF
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
S U
B M
IT
T E
D B
Y
S
IZ
E
IS
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
®of Engineers
US Army Corps
-J
A N -2
:4
P
IT
T S
B U
R G
H D
IS
T R
IC
T
L
IB
E R
T Y A
V E
N U
E
P
IT
T S
B U
R G
H P
A
P L
O T D
A T
E
M O
N O
N G
A H
E L
A R
IV
E R B
A S
IN
L O
W E
R M
W E
R M
O N A
R E
A O
F F
IC
E R
E H h e e t o f
GRAPHIC SCALE
N
0 40 40 80FT
SCALE: 1’’= 40’
FLOW
MONONGAHELA RIVER
FOUNDATIONS
EXISTING BUILDING
UST’S
EXISTING
POLE (PP)
EXISTING POWER
PP
INV EL 765.96
RIM EL 775.66
EXISTING MH
SEWER
EXISTING SANITARY
INV EL 767.03
RIM EL 774.93
REMOVE MH
MAIN
SEWAGE FORCE
FO
E S
W
FS
FG
FW
SR 906
SR 906
BETWEEN MH’S
WITH GROUT
FILL SEWER
SEWER TO BE REPLACED
EXISTING STORM
TRACKS TO REMAIN
GAS LINE
SLEEVE
LIMITS
WORK AREA
CROSSING (BORING)
SANITARY SEWER
TRACKS
REMOVE
MODIFIED CURB
STATION
GAS METERING
EXISTING
TRAILER
GOV’T
PARKING
PAVED
BASIN
TYP CATCH
LIMITS
WORK AREA
CROSSINGS (BORINGS)
WATER/GAS
BRIDGE
ACCESS ROAD
T
GATE IN FENCE
CENTER 16’ SLIDE
FENCED AREA
PAVE ENTIRE
NEW MH
ROAD
ESPLANADE ACCESS
M A
T C
H
D
A W
IN
G
L C
H
OUTFALL FROM SR 906
EXISTING STORM
APPROXIMATELY 20 EACH
REMOVE TREES
EXISTING FENCE
TIE IN LOCATION
GAS AND WATER
H
IB
B S
S R
F
H
IB
B S
S R
F
G
REPLACE INLET
REMOVE AND
REPLACE INLET
REMOVE AND
INLET
REMOVE
PAVE APRON
CSX
CSX
CSX
CSX
CSX
CSX
CSX
PRIVATE
PRIVATE
PRIVATE
ESPLANADE ACCESS ROAD
SWING GATE ON
SECURITY TYPE
WIDE DOUBLE LEAF
INSTALL NEW 14’
NOTES:
1. REFER TO DRAWING 4/1 FOR OVERALL SITE PLAN KEY.
2. EXISTING FEATURES SHOWN AS "HALF TONE."
PROPOSED FEATURES SHOWN AS "BOLD."
D J
H G
E N
E R
P
A N
FIRE HYDRANT
RELOCATED
NEW LOCATION, THIS SHEET
FIRE HYDRANT. SEE
RELOCATE
EXISTING STEPS
STOP SIGN
GROUT BY OTHERS
TANK FILLED WITH
CONTRACTOR’S TRAILER
AREA AVAILABLE FOR
MANHOLE SEE NOTE 3.
REMOVE INLET, PROVIDE NEW
3. COORDINATE MANHOLE WITH E&S/NPDES MEASURES.
AREA LIMITS
WITHIN WORK
REMOVE RR TRACKS
PPWATER LINE
RELOCATED
GAS LINE
RELOCATED
SEWER CONNECTION
STORM
STORM OUTFALL
REPLACE EXISTING
GAS LINE
WATER LINE
(INSTALL BUMPER STOPS)
TRACK REMOVAL LIMIT
JERSEY BARRIER
POWER POLE
SANITARY MANHOLE SS
FACILITY WATER
FACILITY GAS
FACILITY SANITARY
WORK AREA LIMITS
EXISTING WATER
EXISTING GAS
EXISTING SANITARY
EXISTING ELECTRIC
EXISTING FIBER OPTIC
EXISTING TELEPHONE
LEGEND
DRAINAGE, TYPICAL
1’-0" APART TO ALLOW FOR
SPACE JERSEY BARRIERS
REMOVE INLET
SEDIMENTATION PONDS
A
B D
R A
W
V
IS
M
D
IF
IC
A T
IO
V
S R
F
FS
FS
FS
FW
FG
FW
FG
TELEPHONE
ELECTRIC AND
UNDERGROUNDAC
C
ES
S
R
O
AD
AT ABUTMENT
END FENCE
UNDERDRAINS
MSE WALL
A
B
A
MANHOLE (TYP)
M A
T
A W
L C
H
.2
STA 11+28.5 OFFSET 74’ RT
REUSE FABRIC
BEGIN FENCE REMOVAL.
EXISTING FENCE POST.
LINK SECURITY FENCE AT
BEGIN NEW 7’ CHAIN
E
N D
M E
N T
U L
F
C D
R A
W
V
IS
E D
A S
B U
IL
T
F
L P
B
037-LCH- 4/3.3
D e s c r ip t io n D a t e
S y m b o l
A p p r
S E
C T
IE
F
D e s ig n b y
D w n b y
C k d b y
S u b m is s io n a t e
S u b m it t e d b y
R e v is t e
IF
D A
C W
Drawing Number:
U s e r
D a t e
P lo t
S c a le
P e b le
C o lo r
T a b le u s e r n a m e s y t im e ip s c a le ip p e n t a b le c o lo r t a b le f il e n a m e
LOCK IN SAFETY, DAM UP ACCIDENTS
Pittsburgh District of Engineers
US Army Corps
M O
N O
N G
A H
E
IV
E R
C H
A R
L E
R O I L
O C
K
M
S
V E
L O
P M
E N
T
7+0
6+
E l e v
E
N
W R
G R
W R
G R
W A
L L
C B
O
W E
R
JERSEY BARRIER (15’ FROM CL OF RR, TYPICAL)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X X
X
X X X X X X X
X
X
X
X
X
X
X
XX
X
X
X
X
C
C
5+23.39LT, 32.44
20" VALVE
CONDUIT, 18"
FUTURE GATE
X X X X X X
NEW
@ 2+26.57LT, 29.62
2+26.20LT, 9.08
20" VALVE
C
C
INV EL 756.78
SLEEVE C
INV EL 756.78
SLEEVE
C
2+23.08LT, 12.4
6" VALVE
C
C
C
INV EL 755.00
WATER SLEEVE
INV EL 755.25
GAS SLEEVE
C
C
INV EL 755.09
WATER SLEEVE
INV EL 754.99
GAS SLEEVE
C
WATER METER
"AS-BUILT" - 4 APRIL 2005
O37-LCH-4/3.1 DUE TO MODIFICATION NO. 1.
4. THIS DRAWING SUPERSEDES DRAWING
s
K E
G
BUILDING LIGHTING PANELS
POWER PANEL TO LMAO
FOR WIRING CIRCUITS FROM
PROVIDE 3-1•" GRS CONDUITS
FOOT BASE, TYP
12" DIA CONCRETE
4" OF GRAVEL, TYP
TYP
COPPER CLAD,
10FTxƒ" DIA
GROUND RODS,
4'-0"
1PH, 3W
100KVA, 120240V,
TRANSFORMER POLE
EXISTING ELECTRIC
POWER PANEL
250V, 1PH, 3W
RELOCATED 600A,
22'-0"
CAP FOR FUTURE USE
AT THIS LOCATION AND
STOP COMM. CONDUIT
3 LOCATIONS
FITTING, TYP FOR
CONDUIT EXPANSION
EXISTING COMM. POLE
EXISTING FENCEEXISTING FENCE
10'-0"
EVERY 20FT, TYP
WITH INTERNAL BONDING
OZ/GEDNY TYPE AX-150
CONDUIT EXPANSION FITTING
POST, TYP
CONDUIT SUPPORT
POST, TYP
CONDUIT SUPPORT
4" OF GRAVEL, TYP
FOOT BASE, TYP
10" DIA CONCRETE
COMM. CONDUIT
CAP FOR FUTURE USE
STUB UP CONDUIT AND
POWER CONDUITS
(EXISTING)
LIGHTING PANEL #3
(EXISTING)
LIGHTING PANEL #3
(EXISTING)
LIGHTING PANEL #2
POST, TYP
CONDUIT SUPPORT
SERVICE DROP CONDUCTORS
EQUIPMENT
FOR SUPPORTING
WITH S.S. HARDWARE
BOLTED ON POSTS
ALUMINUM SHEET
8FTx8FTx‚" THICK
CONCRETE BASE, TYP
POST WITH 4FT IN
4"x4" TREATED WOOD
POWER PANEL
TO RELOCATED CT CABINET AND
NEW SERVICE ENTRANCE CONDUCTORS
ENTRANCE HOLE
CAP EXISTING SERVICE
SECURED ON POLE
PVC SCH 80 CONDUIT RISER WITH SERVICE WEATHERHEAD
WOOD, CLASS 5, 35FT MIN IN LENGTH, PROVIDE 4"C
APPROVED POLE, TREATED WITH CHEMICAL PRESERVATIVE
CONTRACTOR SHALL PROVIDE AND INSTALL A UTILITY
DETAIL BELOW
NEW POLE, SEE
AND POWER PANEL
METER, CT CABINET
RELOCATED ELECTRIC
TO BE RELOCATED
AND POWER PANEL)
(METER. CT CABINET
SERVICE EQUIPMENT
EXISTING ELECTRIC
POWER PANEL)
BACKGROUND (METER, CT CABINET AND
SERVICE EQUIPMENT ON ALUMINUM
NEW PROPOSED LOCATION OF ELECTRIC
POWER LINES TO EXISTING LIGHTING PANELS, TYP FOR 3 LOCATIONS.
CONDUIT BODY LB NEAR GRADE LEVEL BEHIND BUILDING FOR
CONNECT NEW GRS CONDUIT TO EXISTING PVC CONDUIT UTILIZING7.
SINGLE CHANNEL SIDE, TYP.
CAT. B-LINE #B22A3 WITH PIPE CLAMPS, HARDWARE MOUNTED ON
CONDUIT SUPPORT GALVANIZED STEEL POST COMBINATION CHANNEL,6.
POWER COMPANY REQUIREMENTS.
ELECTRIC SERVICE SHALL BE INSTALLED IN ACCORDANCE WITH ALL
CONTRACTOR SHALL COORDINATE WITH THE POWER COMPANY.5.
PROVIDE AND INSTALL NEW GROUND RODS AT INDICATED LOCATIONS.4.
BUILDING.
CONDUIT BODY LB FOR ROUTING POWER LINES INTO LMAO
CUT AND RE-WORKED TO NEW GRS CONDUITS WITH 1•" HUB
EXISTING PVC CONDUITS AT BUILDING FOUNDATION SHALL BE3.
BY OTHERS.
THESE CUTS WILL BE CONNECTED TO RELOCATED SERVICE PANEL
EXISTING CONDUITS TO TRUMBULL-BRAYMAN TRAILERS SHALL REMAIN.2.
REPLACE SERVICE ENTRANCE CONDUCTORS AS SAME AS EXISTING.1.
NOTES:
MIN
M
IN
M
IN
G G
G G
G G
GROUND ROD, TYP
AND CADWELD TO
ELECTRIC SERVICE
IN ƒ"C, PVC AT
COPPER WIRE #1/OAPPROX
M
IN
M
IN
3 7 3 7 73
SHALL REMAIN
TO LMAO BUILDING
EXISTING COMM. CONDUIT
4-1•"C, GRS
SCALE: NTS
ELECTRIC SERVICE DETAIL5
SCALE: NTS
CONDUIT SUPPORT DETAIL
SCALE: NTS
LMAO ELECTRIC SERVICE REPAIR - SITE PLAN
EXISTING LMAO BUILDING
NATIONAL ELECTRICAL CODE NFPA 70.
ALL ELECTRICAL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE2.
AT ALL TIMES DURING CONSTRUCTION.
THE CONTRACTOR SHALL MAKE PROVISIONS TO MAINTAIN POWER TO SITE1.
GENERAL NOTES:
BACK DOOR
G G
1-2"C PVC FOR COMM.
2-2"C PVC FOR POWER
SHALL REMAIN
TO THE TRUMBULL-BRAYMAN TRAILERS
EXISTING CONDUITS LAYING ON GROUND
LIGHTING PANELS
AND WIRING TO LMAO BUILDING'S
3-1•"C PVC LAYING ON GROUND
DE-ENERGIZE AND REMOVE EXISTING
LMAO BUILDING
3 EXISTING LIGHTING PANELS IN THE
THE RELOCATED POWER PANEL TO THE
PROVIDE AND INSTALL NEW CABLE FROM
NEW OVERHEAD SERVICE DROP
1-1•"C GRS FOR COMM.
3-1•"C GRS FOR POWER
LMAO BUILDING
NEW CONDUITS TO
TO EXISTING LIGHTING PANELS
THE BUILDINGS CRAWL SPACE
EXISTING 3-1•"C PVC ACROSS
10’-0"
5’
11- 6"
145’-2"
45°
CROSSING POINTS.
NO JOINTS LOCATED DIRECTLY BENEATH
TO TOP OF WATER LINE AT CROSSING POINTS.
CLEARANCE FROM BOTTOM OF 15" RCP’S
MAINTAIN MINIMUM OF 18" VERT
GAS METER
CASING INV EL 755.25
VENT
X
X
8"
8"
CASING INV EL 755.00
CASING INV EL 755.03
CASING INV EL 754.99
VENT
POLE
POWER
D R
A W
V
IS
E D
A S
B U
IL
T
L P
B
"AS-BUILT" - 4 APRIL 2005
4" FORCE MAIN
INV EL 755.88
C
C
C
C
X X X X 766.59
C
C
C
C
C
C
C
C
C
C
INSURE 42" COVER IN SWALE C
C
C
D R
A W
V
IS
D
IF
IC
A T
4"FORCE MAIN (FM)
BORE UNDER RR
65 FEET IN LENGTH
W R
G R
W R
G R
GRAPHIC SCALE
N
0 40 40 80FT
SCALE: 1’’= 40’
4"FM
RIM EL. 775.66
ABANDONED
TO BE
WATER LINE
EXISTING
TO BE ABANDONED
TO FIRE HYDRANT
EXISTING LATERAL
FIRE HYDRANT
REMOVE AND RELOCATE
RELOCATED FIRE HYDRANT
TO EXISTING
TIE IN NEW WATER LINE
FM
ABANDONED FUEL TANKS
P R
A T
H E
R J
F L
A C
C E
A D
U I
T I
L I
Y
I
L O
C A
T I
O N
D J
H B
E W
D J
M
STA 5+08, OFF 30’
STA 5+22, OFF 35’
REMOVED
MANHOLE 403, TO BE
EXISTING SANITARY
BETWEEN MH 403 AND 403A
SEWER WITH GROUT
FILL SANITARY
S h e e t o f
BY OTHERS
TANK FILLED WITH GROUT
THIS ABANDONED FUEL
FORCE MAIN, SEE DWG 67/4
FOR SANITARY SERVICE
NEW SANITARY MANHOLE (403A)
BY OTHERS
OVERHEAD ELECTRIC TO UNDERGROUND
STA 2+18, OFF 11’ LT
STA 3+02, OFF 10’ RT
INFLOW EL. 766.5
STA 5+82.5
(4" STEEL PIPE) FOR GAS LINE
SLEEVE THROUGH MSE WALL
M A
T
A W I
X
X
X
X
X
X
X
X
X
X
MH INV EL. 765.5
O37-LCH-67/1.3
D e s c r ip t io n D a t e
S y m b o l
A p p r
S E
C T
IE
F
D e s ig n b y
D w n b y
C k d b y
S u b m is s t e
S u b m it t e d b y
R e v is t e
IF
D A
C W
Drawing Number:
U s e r
D a t e
P lo t
S c a le
P e b le
C o lo r
T a b le u s e r n a m e s y t im e ip s c a le ip p e n t a b le c o lo r t a b le f il e n a m e
LOCK IN SAFETY, DAM UP ACCIDENTS
Pittsburgh District of Engineers
US Army Corps
M O
N O
N G
A H
E
IV
E R
C H
A R
L E
R O I L
O C
K
M
S
V E
L O
P M
E N
T
3"W
A
A A
M E
N D
M E
N T
U L
F
B S
R F
M H
M H
15" RCP
C
C
C
C
C
1+
7+0
6+
.3
SEWER
SANITARY
EXISTING
REGULATIONS BEFORE INSTALLATION BEGINS.
REPRESENTATIVE TO REVIEW INSTALLATION POLICIES AND
SHALL COORDINATE MEETING WITH GAS COMPANY
SUPPLIED AND INSTALLED BY GAS COMPANY. CONTRACTOR
DENNISE MILES (724) 292-3417. BUILDING GAS METERS
PERMIT AND TAP DETAILS. P.O.C. AT GAS COMPANY IS
(DOMINION-PEOPLES NATURAL GAS) FOR INSTALLATION
CONTRACTOR TO COORINATE WITH GAS COMPANY
WITH SPECIFICATION SECTION 02556, GAS DISTRIBUTION.
4. GAS SERVICE LINE TO BE INSTALLED IN ACCORDANCE
3. WATER PIPING TO BE COPPER OR HDPE, SIZES AS SHOWN.
PIT AND BETWEEN METER PIT AND BUILDING.
RESPONSIBLE FOR INSTALLING PIPE BETWEEN TAP AND METER
INSIDE. CONTRACTOR TO INSTALL METER PIT AND TO BE
FOR INFORMATION. METER PIT COMES WITH METER AND PIPING
1 MONTH. CONTRACTOR TO CONTACT WATER COMPANY
FROM WATER COMPANY. LEAD TIME FOR PURCHASE IS ABOUT
2. CONTRACTOR TO PURCHASE 2" METER AND METER PIT
P.O.C. FRANK FRASCATORE].
WATER COMPANY [BOROUGH OF CHARLEROI (412) 483-3585)
FOR TAPPING FEE AND FOR COORDINATING TAP WITH
BY WATER COMPANY. CONTRACTOR TO BE RESPONSIBLE
1. TAP TO EXISTING WATER LINE TO BE PERFORMED
NOTES:
WATER
20" EXIST.
EXISTING
8" GAS
SEE NOTE 1.
P.O.C. NEW WATER LINE
PIT
METER
WATER
SEE NOTE 4.
P.O.C. NEW GAS LINE (1�")
UNDER RR
LENGTH. BORE
GAS EACH 65’
4" ON NATURAL
6" ON WATER
CASING PIPE
MON VALLY SEWAGE AUTHORITY [BEN LEVONDOSKY (724) 379-4141.].
SEE LIFT STATION DETAILS, SHEET 037-LCH-67/3. P.O.C. IS
DETAILS FOR NEW MANHOLE MH#403 SHOWN ON SHEET 037-LCH-67/4.
INSTALLATION SHALL BE COORDINATED WITH LOCAL UTILITY.
5. SANITARY SEWER, FORCE MAIN, AND LIFT STATION
IN ACCORDANCE WITH CSXT REQUIREMENTS.
OFFICER’S REPRESENTATIVE TO COORDINATE RAIL ROAD CROSSING
AS NOTED. CONTRACTOR TO COORDINATE WITH CONTRACTING
SA 53, TYPE "S", GRADE "B" GALVANIZED STEEL PIPE, SIZE
LINES USED AS CASING PIPING ACROSS TRACKS SHALL BE ASME
DOMESTIC WATER - HDPE PE 3408 SDR 7.
GRADE "B".
FORCE MAIN - STEEL (GALVANIZED) ASME SA 53, TYPE "S",
GRADE "B".
NATURAL GAS - STEEL (GALVANIZED) ASME SA 53, TYPE "S",
CARRIER PIPES ACROSS TRACKS SHALL BE AS FOLLOWS:
FORCE MAINS AND INVERTED SIPHONS; SEWER). LINES USED AS
PIPE LINE SPECIFICATIONS (SEE SPECIFICATION SECTION 02532-
AND MAINTENANCE-OF-WAY ASSOCIATION AND CSX TRANSPORATION
WITH REQUIREMENTS OF PART 5, AMERICAN RAILWAY ENGINEERING
6. UTILITY CROSSING OF RAILROAD SHALL BE DONE IN ACCORDANCE
FORCE MAIN AND WATER LINES.
7. PROVIDE THRUST BLOCKS AT ALL CHANGES IN DIRECTION FOR SANITARY
TO MODIFICATION NO. 1.
8. THIS DRAWING SUPERSEDES DRAWING 037-LCH-67/1.1 DUE
S
E
G
W
F O
G/R
W/R
ELECTRIC (OVERHEAD)
GAS RELOCATED
SEWER
GAS
WATER
WATER RELOCATED
LEGEND
FIBER OPTIC (OVERHEAD)
FORCE MAIN
1�"G
1�"G
| 1_sk01 |
| References |
| 20% exist bldg, PW_WORKDIR:dms87859 |
| office existing modifications.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| 20% UTILITIES, PW_WORKDIR:dms87859 |
| 6701_um101_m1z REVISED.dgn |
| PW_WORKDIR:dms87859 |
| office new.dgn |
| 2_sk02 |
| References |
| exist bldg modifications, PW_WORKDIR:dms87859 |
| office new.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| 3_sk03 |
| References |
| exist bldg modifications, PW_WORKDIR:dms87859 |
| office existing modifications.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| 4_sk04 |
| References |
| PW_WORKDIR:dms87859 |
| EXIST-BLDG-FRONT-SECT 1.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| A1 |
| A2 |
| A3 |
| E1 |
| F1 |
| F2 |
| LMAO_Service |
| M1 |
| O37_LCH_40003-3 |
| O37-LCH-67001-3 |
| P1 |
| S2 |
| LMAO Rehabilitation_Sketches and Ref Dwgs_Certified Final Submittal 01112019.pdf |
| sk01 |
| References |
| 20% exist bldg, PW_WORKDIR:dms87859 |
| office existing modifications.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| 20% UTILITIES, PW_WORKDIR:dms87859 |
| 6701_um101_m1z REVISED.dgn |
| PW_WORKDIR:dms87859 |
| office new.dgn |
| sk02 |
| References |
| exist bldg modifications, PW_WORKDIR:dms87859 |
| office new.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| sk03 |
| References |
| exist bldg modifications, PW_WORKDIR:dms87859 |
| office existing modifications.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
| sk04 |
| References |
| PW_WORKDIR:dms87859 |
| EXIST-BLDG-FRONT-SECT 1.dgn |
| PW_WORKDIR:dms88046 |
| _LRP_TitleBlock_FY18.dgn |
File details come from the government source that posted it.