01_11_00,_Amendment_0001.pdf
PDF 213 KB Posted
- Attached to
- Lower Mon Area Office Rehabilitation Federal contract opportunity
- Solicitation number
- W911WN19B8003
About this file
Revised Technical Specifications SECTION 01 11 00 PERFORMANCE WORK STATEMENT
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Lower Mon Ar ea Of f i ce Rehabi l i t at i on
SECTI ON TABLE OF CONTENTS
DI VI SI ON 01 - GENERAL REQUI REMENTS
SECTI ON 01 11 00
PERFORMANCE WORK STATEMENT
PART 1 GENERAL
1. 1 REFERENCES
1. 2 SUBMI TTALS
1. 3 DESI GN SUBMI TTAL PACKAGES
1. 3. 1 Pr el i mi nar y Desi gn Dr awi ngs and Anal yses
1. 3. 2 Fi nal Desi gn Det ai l Dr awi ngs And Anal yses
1. 4 DESCRI PTI ON OF WORK
1. 4. 1 Si t e Ut i l i t y I nvest i gat i on
1. 4. 2 New Of f i ce Bui l di ng
1. 4. 3 New Br eezeway St r uct ur e
1. 4. 4 Exi st i ng Of f i ce Bui l di ng: Ext er i or I mpr ovement s
1. 4. 5 Exi st i ng Of f i ce Bui l di ng: I nt er i or I mpr ovement s
1. 4. 6 Si t e I mpr ovement s
1. 5 MATERI ALS AND STANDARD PRODUCTS
1. 6 GOVERNMENT- FURNI SHED PROPERTY
1. 7 CONTRACT DRAWI NGS
1. 8 ENGI NEERI NG SERVI CES
1. 9 OPERATI ONAL PLAN
1. 10 WARRANTY
1. 11 DESI GN CODES
1. 12 ELECTRI CAL REQUI REMENTS
PART 2 PRODUCTS
2. 1 NEW OFFI CE BUI LDI NG
2. 1. 1 St r uct ur e
2. 1. 1. 1 Desi gn Requi r ement s
2. 1. 1. 2 Foundat i on
2. 1. 1. 3 Bui l di ng Locat i on and Layout
2. 1. 2 Mi scel l aneous Cast - I n- Pl ace Concr et e
2. 1. 3 El ect r i cal
2. 1. 3. 1 El ect r i cal Requi r ement s f or Bui l di ng
2. 1. 3. 2 Communi cat i on Syst ems
2. 1. 4 Mechani cal
2. 1. 4. 1 Wat er Ser vi ce Li ne
2. 1. 4. 2 Bui l di ng Wat er Pi pi ng
2. 1. 4. 3 Bui l di ng Sani t ar y Sewer Pi pi ng
2. 1. 4. 4 HVAC
2. 1. 4. 5 Pl umbi ng Fi xt ur es
2. 1. 5 Ar chi t ect ur al And Fi ni shes
2. 1. 5. 1 Roof i ng
2. 1. 5. 2 Ext er i or Wal l s
2. 1. 5. 3 I nt er i or Wal l s
2. 1. 5. 3. 1 Gypsum Boar d
2. 1. 5. 3. 2 Met al Suppor t Syst em
SECTI ON 01 11 00 Page 1 CERTI FI ED FI NAL DOCUMENT RTA - W911WN19B8003 Amendment 0001
2. 1. 5. 4 I nt er i or Cei l i ng
2. 1. 5. 4. 1 Acoust i cal Ti l e Uni t s
2. 1. 5. 4. 2 Acoust i cal Cei l i ng Suspensi on Syst em
2. 1. 5. 4. 3 Hanger s
2. 1. 5. 4. 4 Fi ni shes
2. 1. 5. 5 Fl oor Decki ng and Fi ni shes
2. 1. 5. 5. 1 Vi nyl Composi t i on Ti l e
2. 1. 5. 5. 2 Car pet Ti l e
2. 1. 5. 5. 3 Wal l Base
2. 1. 5. 5. 4 Mol di ng
2. 1. 5. 6 Pai nt
2. 1. 5. 7 Ext er i or Wi ndows
2. 1. 5. 8 Ext er i or Door s
2. 1. 5. 9 I nt er i or Door s
2. 1. 5. 10 I nt er i or Si gnage
2. 1. 5. 11 Rest r ooms and Toi l et Accessor i es
2. 1. 6 Fur ni shi ngs
2. 2 NEW BREEZEWAY STRUCTURE
2. 2. 1 St r uct ur e
2. 2. 1. 1 Desi gn Requi r ement s
2. 2. 1. 2 Foundat i on
2. 2. 1. 3 St r uct ur e Locat i on and Layout
2. 2. 2 Mi scel l aneous Cast - I n- Pl ace Concr et e
2. 2. 3 El ect r i cal
2. 2. 4 Ar chi t ect ur al And Fi ni shes
2. 2. 4. 1 Roof i ng
2. 2. 4. 2 Ext er i or Wal l
2. 2. 4. 3 I nt er i or Cei l i ng
2. 2. 4. 4 Fl oor Decki ng and Fi ni shes
2. 2. 4. 5 Pai nt
2. 2. 4. 6 Ext er i or Door s
2. 3 EXI STI NG OFFI CE BUI LDI NG: EXTERI OR I MPROVEMENTS
2. 3. 1 St r uct ur e
2. 3. 1. 1 Desi gn Requi r ement s
2. 3. 1. 2 New Mono- sl ope Roof
2. 3. 1. 3 New Roof Gut t er s & Downspout s
2. 3. 1. 4 Exi st i ng Ent r ance Vest i bul e Demol i t i on
2. 3. 1. 5 Rel ocat e Exi st i ng Ent r ance St ai r s
2. 3. 1. 6 Repl ace Exi st i ng Ext er i or Bui l di ng Ski r t i ng
2. 3. 1. 7 Repl ace Exi st i ng Ext er i or Tr i m Boar ds
2. 3. 1. 8 Repl ace Exi st i ng Det er i or at ed Ext er i or Si di ng
2. 3. 2 El ect r i cal
2. 3. 2. 1 El ect r i cal Requi r ement s f or Exi st i ng Ext er i or Li ght i ng
Abandonment at Vest i bul e
2. 3. 2. 2 Repl acement of Ext er i or Li ght Fi xt ur es
2. 3. 3 Mechani cal
2. 3. 3. 1 Ext end Exi st i ng HVAC Condensat e Dr ai n Li nes
2. 3. 3. 2 I nvest i gat e and I mpr ove Under gr ound Sani t ar y Sewer Ser vi ce
Piping
2. 3. 4 Ar chi t ect ur al And Fi ni shes
2. 3. 4. 1 Ext er i or Door s
2. 3. 4. 2 Pai nt
2. 4 EXI STI NG OFFI CE BUI LDI NG: I NTERI OR I MPROVEMENTS
2. 4. 1 El ect r i cal
2. 4. 1. 1 El ect r i cal Requi r ement s f or Par t i t i oni ng Exi st i ng
Conf er ence Room
2. 4. 1. 2 Repl acement of I nt er i or Li ght Fi xt ur es
2. 4. 2 Mechani cal
2. 4. 2. 1 Repl ace Exi st i ng Toi l et s
SECTI ON 01 11 00 Page 2
2. 4. 3 Ar chi t ect ur al And Fi ni shes
2. 4. 3. 1 Par t i t i on Wal l i n Exi st i ng Conf er ence Room
2. 4. 3. 2 I nt er i or Si gnage
2. 5 SI TE I MPROVEMENTS
2. 5. 1 Ci v i l Si t e I mpr ovement s
2. 5. 1. 1 Gr ade t o Dr ai n away f r om Bui l di ngs
2. 5. 1. 2 Rel ocat e Exi st i ng Dumpst er
2. 6 PAI NT MATERI ALS
2. 7 WARRANTY FOR BUI LDI NG SYSTEMS
2. 7. 1 Cont r act or ' s Fi ve Year No Penal Sum War r ant y
PART 3 EXECUTI ON
3. 1 PAI NTI NG
3. 1. 1 Pr ot ect i on Of Ar eas And Spaces Not To Be Pai nt ed
3. 1. 2 Reseal i ng Of Exi st i ng Ext er i or Joi nt s
3. 1. 2. 1 Sur f ace Condi t i on
3. 1. 2. 2 Pr i mer and Bond Br eaker
3. 1. 2. 3 Ambi ent Temper at ur e
3. 1. 2. 4 Ext er i or Seal ant
3. 1. 2. 5 Cl eani ng
3. 1. 3 Sur f ace Pr epar at i on
3. 1. 3. 1 Addi t i onal Requi r ement s f or Pr epar at i on of Sur f aces Wi t h
Exi st i ng Coat i ngs
3. 1. 3. 2 Exi st i ng Coat ed Sur f aces wi t h Mi nor Def ect s
3. 1. 3. 3 Subst r at e Repai r
3. 1. 4 APPLI CATI ON
3. 1. 4. 1 Coat i ng Appl i cat i on
3. 1. 4. 2 Mi xi ng and Thi nni ng of Pai nt s
3. 1. 4. 3 Coat i ng Syst ems
- - End of Sect i on Tabl e of Cont ent s - -
SECTI ON 01 11 00 Page 3
SECTI ON 01 11 00
PERFORMANCE WORK STATEMENT
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN SOCI ETY OF CI VI L ENGI NEERS ( ASCE)
ASCE/ SEI 7 ( 2016; E 2018) Mi ni mum Desi gn Loads f or Bui l di ngs and Ot her St r uct ur es
AMERI CAN WATER WORKS ASSOCI ATI ON ( AWWA)
AWWA C600 ( 2017) I nst al l at i on of Duct i l e- I r on Mai ns and Thei r Appur t enances
AWWA C651 ( 2014) St andar d f or Di s i nf ect i ng Wat er Mains
ASTM I NTERNATI ONAL ( ASTM)
ASTM A489 ( 2018; E 2018) St andar d Speci f i cat i on f or Car bon St eel Eyebol t s
ASTM A641/ A641M ( 2009a; R 2014) St andar d Speci f i cat i on f or Zi nc- Coat ed ( Gal vani zed) Car bon St eel Wi r e
ASTM B88 ( 2016) St andar d Speci f i cat i on f or Seaml ess Copper Wat er Tube
ASTM C1002 ( 2018) St andar d Speci f i cat i on f or St eel Sel f - Pi er ci ng Tappi ng Scr ews f or t he Appl i cat i on of Gypsum Panel Pr oduct s or Met al Pl ast er Bases t o Wood St uds or St eel Studs
ASTM C1047 ( 2014a) St andar d Speci f i cat i on f or Accessor i es f or Gypsum Wal l boar d and Gypsum Veneer Base
ASTM C1396/ C1396M ( 2017) St andar d Speci f i cat i on f or Gypsum Board
ASTM C475/ C475M ( 2017) St andar d Speci f i cat i on f or Joi nt Compound and Joi nt Tape f or Fi ni shi ng Gypsum Boar d
ASTM C635/ C635M ( 2017) St andar d Speci f i cat i on f or Manuf act ur e, Per f or mance, and Test i ng of Met al Suspensi on Syst ems f or Acoust i cal
SECTI ON 01 11 00 Page 4
Ti l e and Lay- I n Panel Cei l i ngs
ASTM C645 ( 2014; E 2015) Nonst r uct ur al St eel Fr ami ng Members
ASTM C920 ( 2018) St andar d Speci f i cat i on f or El ast omer i c Joi nt Seal ant s
ASTM C954 ( 2018) St andar d Speci f i cat i on f or St eel Dr i l l Scr ews f or t he Appl i cat i on of Gypsum Panel Pr oduct s or Met al Pl ast er Bases t o St eel St uds f r om 0. 033 i n. ( 0. 84 mm) t o
0. 112 i n. ( 2. 84 mm) i n Thi ckness
ASTM D2665 ( 2014) St andar d Speci f i cat i on f or Pol y( Vi nyl Chl or i de) ( PVC) Pl ast i c Dr ai n, Wast e, and Vent Pi pe and Fi t t i ngs
ASTM D4214 ( 2007; R 2015) St andar d Test Met hod f or Eval uat i ng t he Degr ee of Chal k i ng of Ext er i or Pai nt Fi l ms
ASTM E795 ( 2016) St andar d Pr act i ces f or Mount i ng Test Speci mens Dur i ng Sound Absor pt i on Tests
ASTM F1066 ( 2004; R 2014; E 2014) St andar d Speci f i cat i on f or Vi nyl Composi t i on Fl oor Tile
ASTM F1861 ( 2016) St andar d Speci f i cat i on f or Resi l i ent Wal l Base
I NTERNATI ONAL CODE COUNCI L ( I CC)
I CC I BC ( 2018) I nt er nat i onal Bui l di ng Code
I CC I ECC ( 2015) I nt er nat i onal Ener gy Conser vat i on Code
I CC I MC ( 2018) I nt er nat i onal Mechani cal Code
I CC I PC ( 2018) I nt er nat i onal Pl umbi ng Code
I NTERNATI ONAL ORGANI ZATI ON FOR STANDARDI ZATI ON ( I SO)
I SO 2551 ( 1981) Machi ne- made Text i l e Fl oor Cover i ngs - Det er mi nat i on of Di mensi onal Changes Due t o t he Ef f ect s of Var i ed Wat er and Heat Condi t i ons
MASTER PAI NTERS I NSTI TUTE ( MPI )
MPI 11 ( 2012) Lat ex, Ext er i or Semi - Gl oss, MPI Gl oss Level 5
MPI 141 ( 2012) Lat ex, I nt er i or , Hi gh Per f or mance Ar chi t ect ur al , Semi - Gl oss ( MPI Gl oss Level 5)
SECTI ON 01 11 00 Page 5
MPI 79 ( 2012) Pr i mer , Al kyd, Ant i - Cor r osi ve f or Metal
MPI 95 ( 2012) Pr i mer , Qui ck Dr y, f or Al umi num
NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)
NFPA 101 ( 2018; TI A 18- 1; TI A 18- 2; TI A 18- 3) Li f e Saf et y Code
NFPA 70 ( 2017; ERTA 1- 2 2017; TI A 17- 1; TI A 17- 2;
TI A 17- 3; TI A 17- 4; TI A 17- 5; TI A 17- 6;
TI A 17- 7; TI A 17- 8; TI A 17- 9; TI A 17- 10;
TI A 17- 11; TI A 17- 12; TI A 17- 13; TI A
17- 14; TI A 17- 15; TI A 17- 16; TI A 17- 17 )
Nat i onal El ect r i cal Code
NSF I NTERNATI ONAL ( NSF)
NSF/ ANSI 61 ( 2017) Dr i nki ng Wat er Syst em Component s - Heal t h Ef f ect s
PENNSYLVANI A DEPARTMENT OF TRANSPORTATI ON ( PDT)
PDT 408 ( 2016) Speci f i cat i ons
SOCI ETY FOR PROTECTI VE COATI NGS ( SSPC)
SSPC PA 1 ( 2016) Shop, Fi el d, and Mai nt enance Coat i ng of Met al s
UNDERWRI TERS LABORATORI ES ( UL)
UL 1598 ( 2008; Repr i nt Oct 2012) Lumi nai r es
TELECOMMUNI CATI ONS I NDUSTRY ASSOCI ATI ON ( TI A)
TIA-568-C.2 ( 2009; Er r at a 2010; Add 2 2014; Add 1 2016) Bal anced Twi st ed- Pai r Tel ecommuni cat i ons Cabl i ng and Component s Standards
U. S. DEPARTMENT OF DEFENSE ( DOD)
UFC 1- 200- 01 ( 2016) DoD Bui l di ng Code ( Gener al Bui l di ng Requirements)
UFC 3- 110- 03 ( 2012: Change 2) Roof i ng
1. 2 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:
Coor di nat e met hod of submi ssi on of r el at ed i t ems wi t h Resi dent Of f i ce
SECTI ON 01 11 00 Page 6 pr i or t o submi t t i ng.
SD- 01 Pr econst r uct i on Submi t t al s
Pr el i mi nar y Desi gn Dr awi ngs and Anal yses; G, DO
Fi nal Desi gn Det ai l Dr awi ngs And Anal yses; G, DO
Condi t i on Repor t
EPDM Roof and Accessor i es; G, DO
SD- 03 Pr oduct Dat a
Sani t ar y Sewer Pi pi ng; G, RO
HVAC I nst r ument at i on And Cont r ol ; G, DO
Pai nt ; G, DO
Ext i ngui sher And Cabi net ; G, DO
Wat er Heat er ; G, DO
Ext er i or Li ght Fi xt ur es; G, DO
Exi t Si gns; G, DO
SD- 04 Sampl es
Col or Char t s; G, RO
SD- 05 Desi gn Dat a
Li ght i ng Panel boar d Schedul e; G, DO
Li ght i ng Fi xt ur e Schedul e; G, DO
SD- 06 Test Repor t s
Emer gency Li ght i ng Oper at i ng Test ; G, DO
Test i ng, Adj ust i ng And Bal anci ng Of HVAC Syst em; G, DO
SD- 10 Oper at i on and Mai nt enance Dat a
Oper at i on And Mai nt enance Manual s
SD- 11 Cl oseout Submi t t al s
Warranty
1. 3 DESI GN SUBMI TTAL PACKAGES
Thr oughout bui l di ng desi gn, t he f ol l owi ng packages ar e r equi r ed t o be submi t t ed f or r evi ew, comment and appr oval . Submi t t al s t hat ar e l i s t ed above whi ch ar e al so l i s t ed i n t he desi gn submi t t al packages do not need t o be submi t t ed t wi ce.
SECTI ON 01 11 00 Page 7
1. 3. 1 Pr el i mi nar y Desi gn Dr awi ngs and Anal yses
Submi t a pr el i mi nar y dr awi ng package and pr el i mi nar y desi gn anal yses f or appr oval wi t hi n 45 cal endar days af t er dat e of Not i ce t o Pr oceed. The dr awi ng package shal l i ncl ude al l i t ems r el at ed t o t he new of f i ce bui l di ng and f oundat i on, new br eezeway st r uct ur e and f oundat i on, and exi st i ng of f i ce bui l di ng, i ncl udi ng new r oof , wi t h modi f i cat i ons shown.
Thi s package shal l i ncl ude, but not be l i mi t ed t o, t he f ol l owi ng i t ems:
a. Fl oor Pl ans. The f l oor pl an dr awi ngs f or t he new of f i ce bui l di ng and new br eezeway st r uct ur e shal l i ncl ude r oom l ayout s wi t h each r oom l abel ed, and di mensi oned. Show l ocat i ons of door ways and wi ndows and wal l t hi cknesses on t he dr awi ngs and consi der i n t he di mensi ons. The f l oor pl an dr awi ng f or t he exi st i ng of f i ce bui l di ng shal l i ncl ude l ocat i ons and di mensi ons of t he pr oposed br eezeway door and conf er ence r oom par t i t i on wal l .
b. El evat i ons. The el evat i on dr awi ngs shal l i ncl ude el evat i on v i ews f or t he f r ont , s i des and r ear of t he new of f i ce bui l di ng, new br eezeway st r uct ur e and exi st i ng of f i ce bui l di ng. These dr awi ngs shal l i ncl ude di mensi ons of t he bui l di ngs and r oof hei ght , t r ansi t i ons ( ver t i cal and hor i zont al ) bet ween bui l di ngs, wi dt h and l engt h, and door way and wi ndow schedul es and l ocat i ons.
c. Sect i ons and Det ai l s. The i nt er i or wal l s, ext er i or wal l s, cei l i ngs and r oof sect i ons and det ai l s shal l show t ypi cal sect i ons wi t h di mensi ons and l abel s f or t he i nt er i or and ext er i or wal l s, cei l i ng and r oof of t he new of f i ce bui l di ng, new br eezeway st r uct ur e, and exi st i ng of f i ce bui l di ng. I nt er i or wal l det ai l s shal l show i nt er f aces bet ween t he wal l f eat ur es, f i ni shed f l oor , and cei l i ng syst em. Ext er i or wal l det ai l s shal l show i nt er f aces bet ween t he wal l f eat ur es, f l oor i ng/ f oundat i on, cei l i ng syst em and r oof syst em. Cei l i ng det ai l s shal l show t ypi cal cei l i ng sect i on. Roof det ai l s shal l show t ypi cal r oof sect i on f or exi st i ng bui l di ng, br eezeway and new bui l di ng.
d. Foundat i on Pl ans and Cal cul at i ons. The f oundat i on desi gn dr awi ngs and cal cul at i ons f or t he new of f i ce bui l di ng and br eezeway st r uct ur e shal l i ncl ude a pl an vi ew showi ng al l mechani cal or el ect r i cal r ough- i ns wi t hi n t he f oundat i on, as wel l as a t ypi cal sect i on showi ng t he f oundat i on st r uct ur e, sub- base, and f oundat i on dr ai ns, i f appl i cabl e. The f oundat i on desi gn must pr ovi de t ot al desi gn l oads at each f oundat i on l ocat i on.
e. Mechani cal Dr awi ngs. The mechani cal pl ans and schemat i cs shal l show pl anned l ocat i ons f or al l mechani cal pl umbi ng ( bui l di ng i nt er i or ) , s i t e ut i l i t i es ( out si de of bui l di ngs) , and HVAC. Pl ans shal l i ncl ude a pl an vi ew showi ng wat er di st r i but i on and sani t ar y sewer pi pi ng and how t hese ut i l i t i es ar e expect ed t o t i e i nt o t he new of f i ce bui l di ng.
f . El ect r i cal Dr awi ngs. The el ect r i cal pl ans and schemat i cs shal l show pl anned l ocat i ons f or al l el ect r i cal and communi cat i ons s i t e ut i l i t i es f or bui l di ng i nt er i or and ext er i or s i t e and how t hese ut i l i t i es ar e expect ed t o t i e i nt o t he new of f i ce bui l di ng.
g. Exi st i ng Bui l di ng Modi f i cat i on Dr awi ngs. The exi st i ng of f i ce bui l di ng modi f i cat i on dr awi ngs shal l show necessar y det ai l s f or modi f i cat i ons f or a new door way t o t he pr oposed br eezeway, al t er at i ons
SECTI ON 01 11 00 Page 8 t o exi st i ng r oof f or new monosl oped r oof , t r ansi t i ons bet ween st r uct ur es and r oof s, addi t i onal par t i t i on wal l ( s) , as wel l as ot her det ai l s not her ei n speci f i ed but necessar y t o compl et e t he wor k.
1. 3. 2 Fi nal Desi gn Det ai l Dr awi ngs And Anal yses
Submi t Fi nal Desi gn Det ai l Dr awi ngs f or al l bui l di ngs and t he f i nal bui l di ng and f oundat i on desi gn anal ysi s f or appr oval wi t hi n 90 cal endar days af t er dat e of Not i ce t o Pr oceed. Submi t dr awi ngs i n pr i nt ed har d copy and el ect r oni c ver si on i n accor dance wi t h Sect i on 01 78 02. 00 15 CLOSEOUT SUBMI TTALS ( AS- BUI LT DRAWI NGS) , par agr aphs Comput er Ai ded Desi gn and Dr af t i ng ( CADD) Dr awi ngs) and Dr af t i ng St andar ds. ALL f i nal desi gn dr awi ngs and cal cul at i ons shal l be s i gned and seal ed by a r egi st er ed desi gn pr of essi onal , l i censed i n t he appr opr i at e di sci pl i ne t o pr act i ce i n a st at e or Commonweal t h of t he US, Puer t o Ri co, or Di st r i ct of Col umbi a.
The f i nal desi gn det ai l dr awi ng package( s) shal l i ncl ude f i nal , appr oved dr awi ng ver si ons, wi t h desi gn pr of essi onal seal and si gnat ur e( s) , and i ncor por at i on of gover nment r evi ew comment s, of t hose i t ems descr i bed under Par agr aph Pr el i mi nar y Desi gn Dr awi ngs and Anal yses f or t he new of f i ce bui l di ng, new br eezeway st r uct ur e, and exi st i ng of f i ce bui l di ng, i ncl udi ng new r oof const r uct i on. Thi s shal l i ncl ude t he f ol l owi ng: ( i ) f l oor pl ans; ( i i ) el evat i ons; ( i i i ) sect i ons and det ai l s; ( i v) f oundat i on pl ans and cal cul at i ons; ( v) mechani cal dr awi ngs; ( v i ) el ect r i cal dr awi ngs;
( v i i ) exi st i ng bui l di ng modi f i cat i on dr awi ngs; and ( v i i i ) cat al og cut s f or pr ocur ement of sensi t i ve, or l ong l ead, f eat ur es.
1. 4 DESCRI PTI ON OF WORK
The wor k shal l t ake pl ace at t he Lower Monongahel a Ar ea Of f i ce, near Monessen, West mor el and Count y, Pennsyl vani a.
The gener al descr i pt i on of t he wor k i ncl udes conduct i ng an under gr ound si t e i nvest i gat i on of t he wor k ar ea( s) ; f ur ni shi ng and i nst al l i ng a compl et e and oper at i onal new of f i ce bui l di ng; i nt er i or and ext er i or i mpr ovement s t o t he exi st i ng of f i ce bui l di ng, i ncl udi ng new mono sl oped r oof ; desi gn and const r uct i on of a new br eezeway st r uct ur e t o connect t he t wo ( new and exi st i ng) of f i ce bui l di ngs; and mi nor ot her s i t e i mpr ovement s.
Desi gn and const r uct t he bui l di ngs and i mpr ovement s t o meet al l l ocal , st at e, and f eder al codes, l aws, and r egul at i ons.
Obt ai n and pay f or al l r equi r ed per mi t s and i nspect i ons of t he bui l di ng const r uct i on as r equi r ed by St at e and l ocal aut hor i t i es havi ng j ur i sdi ct i on. Li censes, i mpact f ees, ut i l i t y f ees, st at e and l ocal t axes, and any and al l per mi t cost t hat may be i mposed ar e t o be i ncl uded i n t he proposal.
1. 4. 1 Si t e Ut i l i t y I nvest i gat i on
Conduct i nvest i gat i on of wor k ar ea t o det er mi ne l ocat i on of exi st i ng s i t e ser vi ce ut i l i t i es wi t hi n t he exi st i ng f ence l i ne. Excavat e t he exi st i ng under gr ound sani t ar y sewer ser vi ce l i nes t o eval uat e i f t he pi pi ng conf i gur at i on meet s r equi r ement s of I CC I PC. Pr ovi de non- dest r uct i ve i nvest i gat i on met hod t o l ocat e exi st i ng under gr ound wat er ser vi ce l i ne( s) wi t hi n t he f ence l i ne. Excavat e t he exi st i ng under gr ound wat er pi pe as necessar y t o det er mi ne separ at i on di st ance f r om sewer l i ne. Fur ni sh r epor t wi t h scal ed sket ch t o Cont r act i ng Of f i cer i ndi cat i ng appr oxi mat e
SECTI ON 01 11 00 Page 9 l ocat i on, dept h, s l ope, pi pe si ze, pi pe mat er i al and separ at i on bet ween t he exi st i ng wat er and sewer ser vi ce ut i l i t i es. I ncl ude scal ed sket ch i n t he r epor t wi t h pr oposed ut i l i t y modi f i cat i ons necessar y t o mai nt ai n a 10- f oot mi ni mum separ at i on bet ween sai d wat er and sewer ut i l i t i es whi l e pr ovi di ng r easonabl e access wi t h r espect t o new of f i ce bui l di ng l ayout .
Ut i l i t y dept h measur ement i s onl y r equi r ed wi t hi n ar eas pr oposed t o be di st ur bed dur i ng const r uct i on of st r uct ur e f oundat i ons or ut i l i t y ser vi ce connect i ons. I ncl ude appr oxi mat e ut i l i t y ser vi ce of f set di st ances f r om exi st i ng bui l di ng and f ence t o accommodat e f ut ur e ut i l i t y l ocat i on. The i nt ent of t hi s wor k i s t o ensur e t hat under gr ound ut i l i t i es ar e consi der ed dur i ng t he l ayout of st r uct ur es, desi gn of f oundat i ons and connect i on of utilities.
1. 4. 2 New Of f i ce Bui l di ng
Fur ni sh al l equi pment , l abor , mat er i al s, suppl i es, l ayout of wor k, and super vi s i on t o desi gn and const r uct a new t empor ar y, one- st or y of f i ce bui l di ng of appr oxi mat el y 1, 680 squar e f eet , f or use by t he Gover nment .
The bui l di ng wi l l consi st of f our of f i ces, a conf er ence r oom, a ut i l i t y r oom, and one women' s r est r oom wi t h t wo st al l s. The new of f i ce bui l di ng f l oor el evat i on shal l mat ch t hat of t he exi st i ng of f i ce bui l di ng f l oor el evat i on wi t hi n +/ - 1/ 4- i nch. The new of f i ce bui l di ng const r uct i on may be pr e- engi neer ed or convent i onal . I f convent i onal , al l cal cul at i ons must be submi t t ed. I f pr e- engi neer ed, met al or modul ar st y l e bui l di ngs ar e bot h accept abl e. The new of f i ce bui l di ng const r uct i on may be a met al or modul ar st y l e pr e- engi neer ed bui l di ng. Al l r el at ed dr awi ngs and cal cul at i ons must be si gned and seal ed by a r egi st er ed desi gn pr of essi onal of t he appr opr i at e di sci pl i ne, l i censed t o pr act i ce wi t hi n a Commonweal t h or st at e of t he US, Puer t o Ri co, or t he Di st r i ct of Col umbi a. Thi s bui l di ng i s t o be used as a t empor ar y, r e- l ocat abl e of f i ce.
1. 4. 3 New Br eezeway St r uct ur e
Fur ni sh al l equi pment , l abor , mat er i al s, suppl i es, l ayout of wor k, and super vi s i on t o desi gn and const r uct a new el evat ed br eezeway st r uct ur e t o connect t he exi st i ng of f i ce bui l di ng wi t h t he new of f i ce bui l di ng, compl et e and i n pl ace. The new br eezeway st r uct ur e wi l l i ncl ude ent r y st ai r s ( st eps and pl at f or m) , r oof , door s, wi ndows, and l i ght i ng. Al l r el at ed dr awi ngs and cal cul at i ons must be si gned and seal ed by a r egi st er ed desi gn pr of essi onal of t he appr opr i at e di sci pl i ne, l i censed t o pr act i ce wi t hi n a Commonweal t h or st at e of t he US, Puer t o Ri co, or t he Di st r i ct of Col umbi a. Thi s bui l di ng i s t o be used as a t empor ar y, r e- l ocat abl e of f i ce.
1. 4. 4 Exi st i ng Of f i ce Bui l di ng: Ext er i or I mpr ovement s
Fur ni sh al l equi pment , l abor , mat er i al s, suppl i es, l ayout of wor k, and super vi s i on t o desi gn and const r uct a new r oof i ng syst em; r epl acement of det er i or at ed si di ng and t r i m; demol i t i on of t he exi st i ng ent r ance vest i bul e; r el ocat i on of exi st i ng al umi num st ai r s; new al umi num st ai r s wi t h pl at f or m; and ot her mi nor i mpr ovement s.
1. 4. 5 Exi st i ng Of f i ce Bui l di ng: I nt er i or I mpr ovement s
Fur ni sh al l equi pment , l abor , mat er i al s, suppl i es, l ayout of wor k, and super vi s i on t o desi gn and const r uct a new par t i t i on wal l and modi f y t he exi st i ng acoust i cal cei l i ng i n t he conf er ence r oom; new ext er i or door t o t he br eezeway st r uct ur e; new t oi l et f i x t ur es; el ect r i cal modi f i cat i ons;
and ot her mi nor i mpr ovement s.
SECTI ON 01 11 00 Page 10
1. 4. 6 Si t e I mpr ovement s
Fur ni sh al l equi pment , l abor , mat er i al s, suppl i es, l ayout of wor k, and super vi s i on t o ensur e s i t e gr adi ng dr ai ns away f r om bui l di ngs; r epl ace desi gnat ed asphal t sur f aci ng i n t he wor k ar ea wi t h new asphal t ; r el ocat e exi st i ng dumpst er ; and r e- r out i ng of I nt er net cabl es and ext ensi on of condui t t o t he exi st i ng of f i ce bui l di ng and r evi se exi st i ng under gr ound sani t ar y sewer pi pi ng f or bot h new and exi st i ng bui l di ngs as necessar y t o i nsur e t he pi pi ng meet s al l code r equi r ement s.
1. 5 MATERI ALS AND STANDARD PRODUCTS
Al l mat er i al s, except t hose desi gnat ed as Gover nment - f ur ni shed mat er i al , shal l be new and f ur ni shed by t he Cont r act or .
Mat er i al s and equi pment shal l be new st andar d pr oduct s of a manuf act ur er r egul ar l y engaged i n t he manuf act ur e of such pr oduct s and shal l essent i al l y dupl i cat e i t ems t hat have been i n sat i sf act or y use f or at l east t wo year s pr i or t o bi d openi ng. Equi pment shal l be suppor t ed by a ser vi ce or gani zat i on t hat i s, i n t he opi ni on of t he Cont r act i ng Of f i cer , r easonabl y conveni ent t o t he s i t e.
1. 6 GOVERNMENT- FURNI SHED PROPERTY
The Gover nment has pur chased t he et her net swi t ch and r out er whi ch ar e t o be i nst al l ed under t hi s cont r act . The et her net swi t ch and r out er wi l l be f ur ni shed t o t he Cont r act or at t he pr oj ect s i t e. The Cont r act or shal l be r esponsi bl e f or i nspect i ng, r ecei v i ng, handl i ng and i nst al l i ng t hese i t ems unl ess st at ed ot her wi se wi t hi n t he speci f i cat i ons. Per f or m a det ai l ed i nspect i on of t he Gover nment - f ur ni shed pr oper t y and pr epar e a br i ef condi t i on r epor t t hat i dent i f i ed each i t em, t he cur r ent condi t i on, and not i f y t he Cont r act i ng Of f i cer of any di scr epanci es. Unl ess ot her wi se speci f i ed, f ur ni sh al l l abor , equi pment , and suppl i es r equi r ed f or r ecei v i ng and i nst al l i ng t he equi pment .
1. 7 CONTRACT DRAWI NGS
Sket ches SK- 01, SK- 02, SK- 03 and SK- 04 ar e pr ovi ded as an at t achment t o t hi s speci f i cat i on. The Sket ches i l l ust r at e t he gener al l ayout of wor k i ncl uded under t hi s cont r act . Al so at t ached t o t hi s speci f i cat i on f or r ef er ence ar e exi st i ng of f i ce bui l di ng shop dr awi ngs ( ni ne t ot al ) . Not e t hat t he sket ches ar e f or i nf or mat i onal pur poses onl y; t he Cont r act or i s r esponsi bl e f or f i nal desi gn and l ayout of al l pr oposed i mpr ovement s as appr oved by t he Cont r act i ng Of f i cer .
1. 8 ENGI NEERI NG SERVI CES
The Cont r act or i s r esponsi bl e f or pr ovi di ng t he appr opr i at e desi gn ser vi ces and pr ovi di ng i nf or mat i on as r equi r ed f or pr el i mi nar y comment and appr oval and r evi s i ng sai d submi t t ed i t ems f or f i nal submi t t al and appr oval and subsequent const r uct i on f or t he new of f i ce bui l di ng and r el at ed f oundat i on; new br eezeway st r uct ur e and r el at ed f oundat i on;
i nt er i or / ext er i or i mpr ovement s t o exi st i ng of f i ce bui l di ng ( new r oof , new ext er i or door , par t i t i on wal l , wat er / sewer pi pi ng modi f i cat i ons, et c…) ;
and si t e ut i l i t y sur vey. The Cont r act or i s al so r esponsi bl e f or pr ovi di ng ut i l i t y connect i ons, s i t e wor k, and pr ovi di ng al l necessar y sur veyi ng and l ayout ser vi ces dur i ng const r uct i on. Sur veys dur i ng const r uct i on shal l be t he r esponsi bi l i t y of t he Cont r act or .
SECTI ON 01 11 00 Page 11
1. 9 OPERATI ONAL PLAN
Devel op and pr ovi de a wr i t t en oper at i onal pl an and war r ant i es at move i n.
The oper at i onal pl an shal l i ncl ude i nf or mat i on on al l emer gency and r egul ar oper at i on of equi pment suppl i ed. I ncl ude cont act number s and names, and l ocat i ons of i nst al l at i on cont r act or s, sub- cont r act or s and war r ant y pr ovi der s i n t he oper at i onal pl an.
1. 10 WARRANTY
Cont r act or and/ or vendor shal l guar ant ee al l l abor , mat er i al s, and equi pment f or a per i od of one year af t er f i nal accept ance of wor k.
1. 11 DESI GN CODES
Obt ai n and pay f or al l r equi r ed per mi t s and i nspect i ons of t he bui l di ng const r uct i on as r equi r ed by St at e and l ocal aut hor i t i es havi ng j ur i sdi ct i on. Li censes, i mpact f ees, ut i l i t y f ees, st at e and l ocal t axes, and any and al l per mi t cost t hat may be i mposed ar e t o be i ncl uded i n t he proposal.
Desi gn and const r uct al l bui l di ngs, st r uct ur es and si t e i mpr ovement s t o meet al l l ocal , St at e, and Feder al codes, i ncl udi ng but not l i mi t ed t o:
I CC I BC
UFC 1- 200- 01
UFC 3- 110- 03
Ref er enced Uni f i ed Faci l i t i es Gui de Speci f i cat i ons
AASHTO
PDT 408
Amer i can Wat er Wor ks Associ at i on
NFPA 101
NFPA 70
I CC I PC
Desi gn and const r uct al l bui l di ng and si t e component s/ syst ems i n accor dance wi t h t he document s l i s t ed above. The l at est edi t i on of t hese codes and st andar ds i n ef f ect and amended as of t he dat e of t he Cont r act or ' s pr oposal wi l l gover n t he desi gn and sel ect i on of t he bui l di ng and si t e component s/ syst ems. The cr i t er i a f r om t hese sour ces may be suppl ement ed but not suppl ant ed by t he appl i cabl e cr i t er i a cont ai ned i n nat i onal r ecogni zed codes and st andar ds. I n case of conf l i c t bet ween t hese r equi r ement s, t he most st r i ngent wi l l appl y. Ref er ences per t ai n t o st andar d speci f i cat i ons of any t echni cal soci et y, or gani zat i on or associ at i on, or t o codes, manual s, r egul at i ons, speci f i cat i on, or t ent at i ve speci f i cat i on adopt ed and publ i shed at l east 90 days pr i or t o submi t t al of pr oposal , unl ess speci f i cal l y st at ed ot her wi se. Al l submi t t al s whi ch ar e based on t he Cont r act or ' s desi gns shal l i ncl ude desi gn cal cul at i ons, assumpt i ons and desi gn r ef er ences used i n pr epar i ng t he desi gns.
I f any r equi r ement s wi t hi n t hi s scope of wor k do not agr ee wi t h r equi r ed codes, not i f y t he Cont r act i ng Of f i cer . I n t he event of an i nconsi st ency bet ween speci f i cat i ons and codes, sat i sf y i ng codes shal l t ake pr ecedence over speci f i cat i on r equi r ement s unl ess t he speci f i cat i on exceeds code requirements.
SECTI ON 01 11 00 Page 12
1. 12 ELECTRI CAL REQUI REMENTS
Al l el ect r i cal component s shal l be desi gned by t he manuf act ur er or a r egi st er ed Pr of essi onal Engi neer as a compl et e syst em. The El ect r i cal desi gner shal l be r egi st er ed t o pr act i ce i n t he par t i cul ar pr of essi onal f i el d i nvol ved i n t he St at e or possessi on of t he Uni t ed St at es, i n Puer t o Ri co, or t he Di st r i ct of Col umbi a. Al l el ect r i cal desi gn dr awi ngs must be st amped by t he el ect r i cal Pr of essi onal Engi neer . Al l component s of t he syst em shal l be speci f i ed by t he desi gner i ncl udi ng, but not l i mi t ed t o el ect r i cal ut i l i t i es, communi cat i ons ut i l i t i es, l i ght i ng, bui l di ng el ect r i cal syst em, and bui l di ng communi cat i ons syst em.
Submi t Det ai l Dr awi ngs f or El ect r i cal Syst em, I dent i f i cat i on f or El ect r i cal Syst ems, Det ai l Dr awi ngs f or Panel boar ds, Low- Vol t age Di st r i but i on Schedul e, Li ght i ng Panel boar d Schedul e, and Li ght i ng Fi xt ur e Schedul e f or appr oval .
PART 2 PRODUCTS
2. 1 NEW OFFI CE BUI LDI NG
2. 1. 1 Structure
2. 1. 1. 1 Desi gn Requi r ement s
The new of f i ce bui l di ng shal l be desi gned by t he manuf act ur er or a r egi st er ed desi gn pr of essi onal ( Desi gner of Recor d) as a compl et e syst em.
The Desi gner of Recor d shal l be r egi st er ed t o pr act i ce i n t he par t i cul ar pr of essi onal f i el d i nvol ved i n a St at e or possessi on of t he Uni t ed St at es, i n Puer t o Ri co, or t he Di st r i ct of Col umbi a. I f t he bui l di ng i s a pr e- engi neer ed st r uct ur e, a desi gn pr of essi onal i s st i l l r equi r ed. All st r uct ur al member s and connect i ons shal l be t he r esponsi bi l i t y of t he Desi gner of Recor d. Al l component s of t he syst em shal l be speci f i ed by t he Desi gner of Recor d. Thi s i ncl udes, but i s not l i mi t ed t o, component s such as f oundat i ons, pr i mar y f r ami ng, secondar y f r ami ng, and l at er al br aci ng. Al l dr awi ngs must be st amped by a Pr of essi onal Engi neer .
a. Desi gn Code - Desi gn l oad appl i cat i on shal l be i n accor dance wi t h
I CC I BC:
b. Dead Loads
c. Li ve Loads
d. Snow Loads
e. Wi nd Load f . Col l at er al l oad shal l i ncl ude t he wei ght of addi t i onal per manent mat er i al s ot her t han t he bui l di ng syst em, such as door s, mechani cal syst ems, and el ect r i cal syst ems. Show equi pment l oads on t he shop ( det ai l ) dr awi ngs and st r engt hen t he st r uct ur e ( f r ame, pur l i ns, gi r t s) as r equi r ed. The Cont r act or i s r esponsi bl e f or pr ovi di ng t he bui l di ng manuf act ur er t he magni t ude and appr oxi mat e l ocat i on of al l concent r at ed l oads bef or e desi gn of t he bui l di ng commences.
g. Rai nf al l I nt ensi t y - Gut t er s and downspout s shal l be 6- i nches i n di amet er . Desi gn suppor t s f or gut t er s and downspout s f or t he ant i c i pat ed l oads.
SECTI ON 01 11 00 Page 13
h. Sei smi c Per f or mance - Desi gn and engi neer bui l di ng syst em capabl e of wi t hst andi ng t he ef f ect s of ear t hquake mot i ons det er mi ned accor di ng to ASCE/ SEI 7, and t he appl i cabl e por t i ons of t he bui l di ng code i n t he geogr aphi c ar ea wher e t he const r uct i on wi l l t ake pl ace.
i . Anchor age - anchor bui l di ng f r ame t o t he f oundat i on f or al l l oadi ng combi nat i ons and combi nat i ons wi t h met al anchor st r aps or ot her appr oved met hod.
j . Si t e Condi t i ons - Desi gn pr oposed addi t i ons and i mpr ovement s t o pr event addi t i onal l oads t o exi st i ng st r uct ur es and ut i l i t i es.
Submi t t he pr el i mi nar y and f i nal New Of f i ce Bui l di ng Dr awi ngs, New Of f i ce Bui l di ng Desi gn Anal ysi s and f oundat i on pl ans f or appr oval i n accor dance wi t h par agr aphs DESI GN SUBMI TTAL PACKAGES and as par t of submi ssi ons r equi r ed by par agr aphs Pr el i mi nar y Desi gn Dr awi ngs and Anal ysi s and Fi nal Desi gn Dr awi ngs and Anal ysi s.
I f any r equi r ement s wi t hi n t hi s scope of wor k do not agr ee wi t h r equi r ed codes, i t i s t he Cont r act or ' s r esponsi bi l i t y t o not i f y t he Gover nment . I n t he event of an i nconsi st ency bet ween speci f i cat i ons and codes, sat i sf y i ng codes shal l t ake pr ecedence over speci f i cat i on r equi r ement s unl ess t he speci f i cat i on exceeds code r equi r ement s.
2. 1. 1. 2 Foundation
Set t he f oundat i on at a dept h bel ow t he f r ost l i ne t o pr event f r ost heave damage t o t he bui l di ng. Est i mat e al l owabl e bear i ng capaci t y f or f oundat i on desi gn pur poses based on t he t ypes of soi l pr esent i n t he ar ea. Ret ai n t he ser vi ces of a qual i f i ed Pr of essi onal Engi neer t o ver i f y t hat t he soi l or r ock exposed at t he f oundat i on l evel dur i ng const r uct i on wi l l have t he bear i ng capaci t y assumed i n t he desi gn.
The f oundat i on shal l i ncl ude a mi ni mum of 6" aggr egat e subbase ( PDT 2A, No. 57, or equi val ent ) .
Al l f oundat i on excavat i on, subgr ade pr epar at i on/ compact i on, subbase aggr egat e, and concr et e f oundat i on shal l be desi gned, f ur ni shed and i nst al l ed by t he Cont r act or . Di spose of excess mat er i al f r om excavat i on i n accor dance wi t h Sect i on 01 74 19. 00 08 CONSTRUCTI ON AND DEMOLI TI ON
WASTE MANAGEMENT.
The pr el i mi nar y and f i nal Foundat i on Det ai l Dr awi ngs and Foundat i on Desi gn Anal ysi s must be submi t t ed f or appr oval i n accor dance wi t h par agr aphs Desi gn Requi r ement s and Foundat i on.
2. 1. 1. 3 Bui l di ng Locat i on and Layout
The l ocat i on and l ayout of t he new bui l di ng shoul d be si mi l ar t o t hat shown i n t he sket ches. The di mensi ons of t he bui l di ng and i nt er i or r ooms shal l be desi gned and submi t t ed by t he Cont r act or , but compl y wi t h t he f ol l owi ng r equi r ement s:
a. The bui l di ng shal l have a mi ni mum appr oxi mat e net ar ea of 1, 680 squar e f eet , and have appr oxi mat e di mensi ons of 60 f eet by 28 f eet ( pl us or mi nus 5- f eet f or ei t her di mensi on) .
b. Ther e shal l be f our of f i ces i n t he bui l di ng wi t h appr oxi mat e
SECTI ON 01 11 00 Page 14 l ocat i ons as shown i n t he sket ches. Al l of f i ces shal l have a mi ni mum net ar ea of 132 squar e f eet .
c. Ther e shal l be one conf er ence r oom wi t h a mi ni mum net ar ea of 840 squar e f eet .
d. Ther e shal l be one women' s r est r ooms wi t h a mi ni mum net ar ea of 84 squar e f eet . Rest r oom shal l i ncl ude t wo t oi l et st al l s mi ni mum and a sink.
e. Ther e shal l be a mechani cal / ut i l i t y r oom wi t h a mi ni mum ar ea of net 72 squar e f eet .
f . The i nt er i or cei l i ng f i ni shed hei ght shal l be a mi ni mum of 8 f eet f r om t he t op of t he f i ni shed f l oor .
2. 1. 2 Mi scel l aneous Cast - I n- Pl ace Concr et e
See Sect i on 03 30 53 MI SCELLANEOUS CAST- I N- PLACE CONCRETE
2. 1. 3 Electrical
2. 1. 3. 1 El ect r i cal Requi r ement s f or Bui l di ng
The exi st i ng el ect r i c ser vi ce i s r out ed t hr ough above- gr ound condui t f r om t he pol e t o t he exi st i ng of f i ce bui l di ng. Rout e power l i nes t o t he new of f i ce bui l di ng i n new gal vani zed r i gi d st eel condui t f r om t he exi st i ng el ect r i c ser vi ce condui t . Ext end t he exi st i ng condui t suppor t f or t he exi st i ng of f i ce bui l di ng t o t he new of f i ce bui l di ng.
Each of f i ce space shal l have a r ecept acl e on each wal l and at l east one dat a por t . The conf er ence r oom shal l have t wo r ecept acl es per wal l and a mi ni mum of f our dat a por t s ( One cent er ed above t he conf er ence r oom t abl e, t wo i n conf er ence r oom wal l s, and one f or a pr i nt er l ocat i on) .
Fur ni sh and i nst al l t he f ol l owi ng conf or mi ng t o NFPA 70:
a. Li ght i ng Panel boar ds: 120- 240 VAC, 1- Phase, 3- Wi r e, NEMA 1 encl osur e, sur f ace mount ed. Al l ow at l east 20 per cent of c i r cui t br eaker s f or spar e. Submi t l i ght i ng panel boar ds f or appr oval .
b. Wi r e: Mi ni mum #12AWG copper wi r e. I nsul at i on r at ed f or 600 vol t s wi l l be ut i l i zed f or al l power cabl es. Al l wi r e and cabl e wi l l be i nst al l ed i n a condui t and/ or cabl e t r ay unl ess ot her wi se not ed.
Submi t wi r i ng f or appr oval .
c. Condui t : Mi ni mum si ze of condui t t o be 3/ 4- i nch, t he power l i ne condui t shal l be 1- 1/ 2" . Al l exposed condui t wi l l be gal vani zed r i gi d st eel and expansi on f i t t i ngs wi t h i nt er nal bondi ng shal l be i nst al l ed ever y 20 f t . Embedded condui t i s not necessar y under t hi s cont r act .
Submi t condui t f or appr oval . See r ef er ence dr awi ng E1 f or t he exi st i ng condui t and ser vi ce det ai l s.
d. Condui t Suppor t : Condui t suppor t s shal l be appr oxi mat el y ever y 10 f eet . The new condui t suppor t post s, bases, c l amps, expansi on f i t t i ngs, and har dwar e shal l be s i mi l ar or equal t o t he exi st i ng supports.
e. Li ght Swi t ches: Si ngl e Pol e and 3- Way.
SECTI ON 01 11 00 Page 15 f . Thr ee- Way Swi t ches: 120 vol t , 15 amp l i ght swi t ches.
g. Dupl ex Recept acl es: 20A, 125 VAC, wal l mount ed and f l oor / cei l i ng mounted.
h. Tel ephone and I nf or mat i on Net wor k Out l et s: Wal l mount ed and f l oor mounted.
i . Submi t Li ght swi t ch and r ecept acl e cover col or s appr oval .
j . Li ght Fi xt ur es: Pr ovi de i nt er i or LED, i n- cei l i ng, over head l i ght i ng wi t h mi ni mum 30- f oot candl es t hr oughout . Submi t al l l i ght f i x t ur es f or appr oval .
k. Ext er i or Li ght Fi xt ur es: Fur ni sh and i nst al l commer ci al ext er i or LED wal l pack l i ght f i x t ur es wi t h dawn t o dusk phot ocel l sensor . The f i xt ur es shal l be heavy dut y, di e- cast al umi num wi t h commer ci al gr ade powder coat pai nt , r at ed f or oper at i on wi t hi n an ambi ent t emper at ur e r ange of mi nus 22 degr ees F t o 104 degr ees F, UL l i s t ed f or wet l ocat i ons per UL 1598, l umi nai r e ef f i c i ency of at l east 60 l umens per wat t , and be f ul l y assembl ed and el ect r i cal l y t est ed pr i or t o shi pment f r om f act or y. Locat i ons of new ext er i or f i x t ur es ar e l ocat ed on t he sketches.
l . Exi t Si gns: Combi ned LED exi t s i gn wi t h 2- head l i ght s and bat t er y backup. Exi t s i gns t o be l ocat ed at al l ext er i or exi t s.
m. Exhaust Fans: Fans shal l be s i zed by Cont r act or t o meet r equi r ed exchange r at es.
n. Vent i l at i on:
Fur ni sh and i nst al l at r est r oom f or vent i l at i on. Fans shal l oper at e on a separ at e swi t ch f r om t he l i ght s and exhaust t hr ough t he r oof .
Fur ni sh and i nst al l an exhaust f an i n t he Ut i l i t y Room. The f an shal l oper at e i n sequence wi t h t he f ur nace. The Ut i l i t y Room shal l be a condi t i oned space suppl i ed by t he f ur nace and exhaust ed by t he exhaust f an t hr ough t he r oof .
o. Gr oundi ng: Pr ovi de equi pment gr oundi ng conduct or s f or al l el ect r i cal equi pment and si zed i n accor dance wi t h NFPA 70. Al l met al l i c condui t s shal l be cont i nuousl y gr ounded. Bond al l gr oundi ng conduct or s t oget her t o f or m a cont i nuous gr oundi ng syst em. Bond t he neut r al and gr oundi ng conduct or at t he ser vi ce di sconnect swi t ch and at separ at el y der i ved syst ems i n accor dance wi t h t he r equi r ement s of
NFPA 70.
Fur ni sh and i nst al l al l el ect r i cal hanger s and suppor t s, Spl i ces and Connect i ons, Out l et s, Out l et Boxes, and Pul l Boxes, El ect r i cal Gr oundi ng and Bondi ng, condui t s, r aceway and f i t t i ngs, and wi r e and cabl e.
Submi t an I nt er i or Li ght i ng Oper at i ng Test , Ext er i or Li ght i ng Oper at i ng Test , and an Emer gency Li ght i ng Oper at i ng Test . Test al l el ect r i cal and communi cat i ons wi r i ng and cabl es wi t hi n t he bui l di ng.
Fur ni sh and i nst al l 1" C EMT condui t connect ed t o ever y wal l r ecessed
SECTI ON 01 11 00 Page 16 communi cat i on out l et box and up t o above dr op cei l i ng t o pr ot ect net wor k i nf or mat i on cabl e i nsi de t he wal l .
2. 1. 3. 2 Communi cat i on Syst ems
Fur ni sh and i nst al l al l r equi r ed communi cat i ons i nsi de t he bui l di ng as descr i bed bel ow. Fur ni sh and i nst al l t he communi cat i ons condui t wi t h pul l strings.
Fur ni sh and i nst al l cabl e t r ay t ype Fl ext r ay above acoust i c cei l i ng syst em f or suppor t i ng communi cat i on cabl es. The l ocat i on of t he t r ay shal l r un c l ose t o t op of wal l s f or cabl es dr oppi ng f r om t r ay t o communi cat i on out l et v i a condui t embedded i nsi de wal l . Secur e cabl e t r ay on t he bui l di ng st r uct ur e ut i l i z i ng t hr eaded r ods br acket s, channel s, and har dwar e per cabl e t r ay manuf act ur er ' s r ecommendat i ons. Use t he cabl e t r ay suppor t i ng net wor k. Gr ound t he cabl e t r ay as r equi r ed per code.
Fur ni sh and i nst al l al l net wor k out l et s, net wor k cabl i ng and t el ephone cabl i ng. Each out l et shal l have a mi ni mum of t hr ee f unct i oni ng por t s. Two por t s ar e t o be wi r ed f or net wor k/ dat a/ VoI P t r ansmi ssi on and one f or t el ephone. Bundl e cabl es and suppor t above t he acoust i c cei l i ng syst em, and r an t hr ough cabl e t r ay wher e possi bl e. Al l net wor k dat a communi cat i on cabl es and t el ephone communi cat i on cabl es shal l home r un t o t he Ut i l i t y Room i n t he exi st i ng bui l di ng, wher e i t shal l be neat l y bundl ed.
I dent i f y/ l abel each cabl e and por t and t est . Fur ni sh and i nst al l a t el ephone box i n t he Ut i l i t y Room. No ser i al por t swi t ches, r out er s, modems, or ser ver s ar e i ncl uded i n t hi s cont r act .
Al l new Et her net cabl i ng must be i n accor dance wi t h TIA-568-C.2 , Cat egor y 6, pl enum cabl es. The RJ45 pl ugs must use t he st andar d T568B wi r i ng scheme.
I nst al l a new Gover nment - f ur ni shed Et her net swi t ch and r out er i n a Cont r act or - f ur ni shed r ack i n t he new equi pment r oom. The new r ack must cont ai n a l ock.
Run new fiber CAT 6 opt i c cabl i ng f r om t he exi st i ng Et her net swi t ch i n t he exi st i ng of f i ce bui l di ng t o t he new Gover nment - f ur ni shed Et her net swi t ch i n t he Ut i l i t y Room. The f i ber opt i c cabl es wi l l be r un t hr ough t he cei l i ng of t he new br eezeway i n condui t .
Submi t t he Communi cat i ons Det ai l Dr awi ngs, I dent i f i cat i on f or Communi cat i on Syst ems, Communi cat i ons Gr oundi ng and Bondi ng, Pat hways, Communi cat i ons Hanger s and Suppor t s, Condui t s, and Backboxes f or appr oval .
2. 1. 4 Mechanical
Al l mechani cal component s shal l be desi gned by t he manuf act ur er or a r egi st er ed Pr of essi onal Engi neer as a compl et e syst em. The Mechani cal desi gner shal l be r egi st er ed t o pr act i ce i n t he par t i cul ar pr of essi onal f i el d i nvol ved i n t he St at e or possessi on of t he Uni t ed St at es, i n Puer t o Ri co, or t he Di st r i ct of Col umbi a. Al l HVAC and pl umbi ng desi gn dr awi ngs must be st amped by a mechani cal Pr of essi onal Engi neer . Thi s may be t he same per son, pr ovi ded t hey ar e qual i f i ed t o desi gn bot h syst ems. Al l component s of t he syst em shal l be speci f i ed by t he desi gner i ncl udi ng, but not l i mi t ed t o mechani cal ut i l i t i es, mechani cal / pl umbi ng, bui l di ng pl umbi ng, and bui l di ng HVAC syst ems.
Submi t t he f ol l owi ng mechani cal f eat ur es f or appr oval as r equi r ed by t hi s
SECTI ON 01 11 00 Page 17 and ot her Sect i ons:
a. PLUMBI NG
Wat er Di st r i but i on Pi pi ng Sani t ar y Sewer Pi pi ng
2. 1. 4. 1 Wat er Ser vi ce Li ne
Pr ovi de a new ser vi ce l i ne f r om t he exi st i ng 3/ 4- i nch di amet er copper wat er l i ne t o t he new bui l di ng. I nst al l t he wat er l i ne wi t h a mi ni mum 48 i nches of cover . The new ser vi ce wat er l i ne shal l be 3/ 4- i nch di amet er Type K sof t copper t ubi ng meet i ng t he r equi r ement s of ASTM B88 and meet i ng r equi r ement s of NSF/ ANSI 61 f or pot abl e wat er . No j oi nt s wi l l be per mi t t ed i n t he copper t ubi ng bet ween t he connect i on t o t he exi st i ng wat er l i ne t o 12 i nches above t he f l oor i n t he Ut i l i t y Room. Pr ovi de pi pe i nsul at i on and heat t r aci ng wi t h t her most at cont r ol f or t he wat er l i ne f r om 2 f eet bel ow gr ade t o wi t hi n t he Ut i l i t y Room. I nsur e 10 f eet hor i zont al separ at i on bet ween wat er and sewer l i ne on under gr ound sect i on of pi pi ng.
Rel ocat e exi st i ng wat er l i ne t o near t he per i met er of t he of f i ce bui l di ng f oot pr i nt t o al l ow access t o t he shut of f val ve behi nd t he ski r t i ng.
Beddi ng and i ni t i al backf i l l f or t he wat er l i ne shal l be sand. Fi nal backf i l l shal l be sel ect mat er i al i n gr ass ar eas and AASHTO #57 under r oads and par ki ng ar eas. Pr ovi de a 6- i nch wi de det ect abl e I D mar ki ng t ape 12" bel ow t he gr ound sur f ace above al l new wat er l i nes.
Pr ovi de al l pi pi ng penet r at i ng t he f oundat i on wal l s, i f appl i cabl e, wi t h SCH 40 PVC pr essur e pi pe sl eeves. Fi l l voi ds bet ween t he car r i er pi pe and sl eeves wi t h f l exi bl e wat er pr oof seal ant . Seal s l eeves t hr ough f i r e r at ed wal l s i n accor dance wi t h NFPA.
Per f or m pr essur e and l eakage t est i ng i n accor dance wi t h AWWA C600.
Di s i nf ect al l pot abl e wat er suppl y pi pi ng i ncl udi ng bui l di ng pi pi ng i n accor dance wi t h AWWA C651.
2. 1. 4. 2 Bui l di ng Wat er Pi pi ng
Pot abl e wat er suppl y pi pi ng shal l be t ype " L" , har d dr awn copper meet i ng t he r equi r ement s of ASTM B88. Sl ope suppl y pi pi ng t o al l ow compl et e dr ai nage. Pr ovi de dr ai n val ves at al l l ow poi nt s. Pr ovi de shut of f val ves f or al l f i x t ur es t o enabl e i sol at i on of f i x t ur es f or r epai r , al l owi ng t he r emai nder of t he bui l di ng f i x t ur es t o be oper abl e. Pr ovi de a gat e or bal l val ve wher e t he wat er ser vi ce ent er s t he bui l di ng. Si ze al l suppl y pi pi ng t o pr ovi de adequat e wat er pr essur e f or oper at i on of t he f i x t ur es wi t h a mi ni mum ser vi ce l i ne pr essur e of 25 PSI , i ncl udi ng ADA r equi r ement s. Fur ni sh and i nst al l pi pe i nsul at i on t o sat i sf y codes under l avat or i es. Pr ovi de a backf l ow pr event er on t he ser vi ce l i ne i n t he Ut i l i t y Room ar ea pr i or t o any br anch ci r cui t s. Pr ovi de a hose bi b i n t he Ut i l i t y Room. Conceal al l pi pi ng wi t hi n t he ser vi ce ar ea. Pr ovi de t wo f r ost f r ee hose bi bs at t he ext er i or of t he bui l di ng. Locat e one hose bi b on t he f r ont and r ear of t he of f i ce bui l di ng. Pr ovi de al l f i x t ur es wi t h an ai r gap, vacuum br eaker or backf l ow pr event er as r equi r ed by t he I nt er nat i onal Pl umbi ng Code. I nst al l al l pi pi ng i n accor dance wi t h I CC I PC.
2. 1. 4. 3 Bui l di ng Sani t ar y Sewer Pi pi ng
Al l under f l oor vent and wast e pi pi ng shal l be SCH 40 PVC DWV meet i ng t he r equi r ement s of ASTM D2665. Al l j oi nt s and f i t t i ngs shal l be sol vent wel d. Voi ds bet ween t he car r i er pi pes and bui l di ng f l oor shal l be f i l l ed
SECTI ON 01 11 00 Page 18 wi t h f l exi bl e wat er pr oof seal ant . Ext end t he new of f i ce bui l di ng sani t ar y sewer pi pi ng t o t he exi st i ng sani t ar y sewer ser vi ce l i ne l ocat ed at t he pr oposed bui l di ng s i t e; t he Cont r act or i s r…