W911SA20B2003 Attachment 9 Asbestos Report Seed Project.pdf
PDF 3 MB Posted
- Attached to
- 63rd RD MAID-IQ Region 2, TX Federal contract opportunity
- Solicitation number
- W911SA20B2003
About this file
This document is an asbestos reinspection report for the Victoria U.S. Army Reserve Center in Victoria, Texas. The report details an inspection of previously identified asbestos containing materials to assess their current status. Asbestos samples were originally taken and identified in an initial inspection report included as an appendix. The reinspection found that some originally identified materials had been removed, while others remained in damaged or good condition. An additional sample was taken of suspect material in the ladies latrine and did not detect any asbestos. Photographs in an appendix document the apparent removal of some materials and the current condition of others. Laboratory results of the samples are also included in the appendix.
The related federal contract opportunity is for design-build projects for the 63rd Regional Division, Region 2 in Texas, to be performed in accordance with specifications, drawings, and contract documents. The solicitation is being offered through the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort McCoy.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS BUILDING
REINSPECTION
Victoria U.S. Army Reserve Center Victoria, Texas
Prepared by:
U.S. Army 90th Regional Support Command
August 1998
Table of Contents
1.0 INTRODUCTION 1
2.0 INSPECTION SCOPE 1
3.0 CONCLUSIONS 1
Appendices
A. SITE PHOTOGRAPHS
B. ORIGINAL ASBESTOS INSPECTION
C. SAMPLE RESULTS
D. INSPECTOR QUALIFICATIONS
1.0 INTRODUCTION
A review of the Asbestos Inspection for Victoria (TX075) United States Army Reserve Center (USARC), 406 North Ben Jordan Street, Victoria, TX, was performed by the Environmental Section at the 90th Regional Support Command, United States Army Reserve (USAR), 8000 Camp Robinson Road, North Little Rock, AR 72118. The original inspection was performed under Fort Sam Houston and is included with this report.
2.0 INSPECTION SCOPE
The purpose of this inspection is to assist in the compliance with Army Regulation 200-1, Chapter 10, Sections 2 & 3. Parts “j” and “k” of section two state:
The Army will
j. Perform surveys to identify the existence, extent, and condition of all* asbestos (both friable and nonfriable) in all DA- controlled structures. Ensure that these surveys are kept current.
k. Identify in detail and validate the existence, extent, and condition of all* asbestos (both friable and nonfriable) in structures prior to renovation, demolition, or excessing. Ensure that employees, visitors, and contractors are appropriately notified of any asbestos related health hazard**. Ensure that working conditions are safe and that all actions are performed per Federal, State, local, and host- nation requirements.
* this survey may not identify all possible asbestos. Some asbestos may not be found until demolition is planned.
** the inspection does not include hazard identification. Some aspects of hazard are addressed in the management plan described by Section 3 of Chapter 10.
3.0 CONCLUSIONS
An attempt was made to find Asbestos Containing Materials identified in the original survey.
Photos were taken to document the apparent removal of material. The originally identified materials and their current status are as follows:
Original Sample Number
Material Status
A.0101 Floor Tile and Adhesive Removed A.0401 Mastic/ Insulation Seams Good A.0501 Roofing Material Damaged A.0601 Expansion Gasket/ Joint Damaged A.0801 Boiler Breaching Damaged A.0901 Air Duct Insulation Removed A.1001 Vibration Gasket Removed A.1201 Tank Side Removed A.1301 Side Door Gasket Damaged A.1401 Domestic Cold Fittings Removed A.1601 Chilled Water Fittings Removed A.1602 Chilled Water Lines Removed A.1701 Heating Water Fittings Removed A.1702 Heating Water Lines Removed B.0101 Floor Tile and Adhesive Removed B.0201 Baseboard Removed
B.0301 Expansion Gasket/ Joint Significantly Damaged B.0501 Roofing Material Damaged
An additional sample was taken of suspect texturing material in the ladies latrine at the USAR Center. No Asbestos was detected in the sample. Laboratory results are included in the appendix.
Appendix A Site Photographs
Figure 1 Victoria USAR Center
Figure 2 Replacement Air Duct Insulation and Heated Water Lines
Figure 3 Fiberglass Replacement Water Lines
Figure 4 Boiler with Breeching
Figure 5 Replacement Water Lines on Boiler
Figure 6 Replacement Fiberglass Insulation
Figure 7 New Floor Tile and Baseboards
Figure 8 Replacement Air Duct Insulation and Vibration Collar
Figure 9 Surface Texture in Latrine
Figure 10 ACM Expansion Joints-Maintenance Shop
Appendix B Original Survey
Appendix C Laboratory Sample Results/ Location Map
Appendix D Inspector Qualifications
File details come from the government source that posted it. Updated .