Attachment A Fire Alarm Inspection Report
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
“Company Name”
FIRE ALARM SYSTEMS
ITM REPORT/SPRINKLER
JBLM, WASHINGTON
| Building Name: |
| Monitoring Contact: |
| Building #: |
| Joint Base Emerg. Control Center (JBECC) |
| Inspection Date: Time: 0700 |
| Telephone: 253-912-4442 |
| Company Information: |
| Approving Agency: |
| Name: |
| JBLM Lewis Public Works; Joe Jones |
| Address: |
| C/0 Services Management Branch |
| Telephone: |
| Telephone: 253-966-XXXX |
Contract #:
Fire Prevention Officer: Individuals Name Testing Letter Given To: _________________ Date: ___________ *Inform person-receiving letter, it is to be delivered to Fire Alarm Building Manager.
| Transmitter Information: |
| Transmitter Zone Information: |
| Zone |
| Time |
Z-1:
Z-2:
Z-3:
Z-4:
Z-5:
Z-6:
Z-7:
Notes:Sensitivities done with UL217 smoke
#: Manufacturer: Monaco
Type of Transmission: RF
Type of Service: Annual
Location:
FACP Information:
FACP Manufacturer: Model #:
Circuit Class: Initiating: Indicating:
# of Circuits: Initiating: Indicating:
Software Rev.:
Last date service performed: First time new FACP system/building tested on this contract.
POC: _____________ POC#:____________________
Alarm Initiating Devices Information
| Quantity |
| Manufacturer |
| Part # |
| Device Types |
Pull Stations
Sync Module
Smoke Detectors
Duct Detectors
Monitor Modules
PRIOR TO ANY TESTING
| Notifications Are Made: |
| Yes |
| No |
| Person Contacted |
| Time |
| JBECC Monitor |
| |X| |
| |_| |
| JBLM Public Works QC |
| |X| |
| |_| |
| Joe Manfred |
| 0700 |
| Building Manager; CQ/OIC/NCOIC |
| |X| |
| |_| |
| AHJ/DPW (Notified) of any impairments |
| |_| |
| |X| |
N/A
FACP System Power Supplies
| a. |
| Primary (Main): Nominal Voltage: 120V ac |
| Amps: 20 |
| Over Current Protection: Type: Circuit Breaker |
| Amps: 20 |
Location (Panel Number):
Disconnecting Means Location: Circuit breaker #
Breaker Lock Installed? Yes |_| No |_| Secured inside mechanical room controlled by Public Works keys, no lock requested per Fire Department.
| b. |
| Secondary (Standby): 72 hours and 15 minutes in alarm OR 48 hours and 5 minutes in alarm |
Battery Calculation Unavailable: Cannot determine system operation design hours
| c. |
| Surge Suppressor for line Voltage: |
| Manufacturer: Transtector |
| Model #: ACP100BWN3 |
| Red indicator light on: Yes|_| No|_| |
| Condition good: Yes|_| No|_| |
FACP Batteries
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Load Voltage After 5 minute alarm:
|X| |_|
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
Transmitter Batteries
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
BPS #1 Batteries: Locaction AC Pwr Bkr:
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Load Voltage After 5 minute alarm:
|X| |_|
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
BPS #2 Batteries: Locaction AC Pwr Bkr:
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Load Voltage After 5 minute alarm:
|X| |_|
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
BPS #3 Batteries: Locaction AC Pwr Bkr:
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Load Voltage After 5 minute alarm:
|X| |_|
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
BPS #4 Batteries: Locaction AC Pwr Bkr:
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Load Voltage After 5 minute alarm:
|X| |_|
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
BPS #5 Batteries: Locaction AC Pwr Bkr:
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |X| |_| |
Load Voltage After 5 minute alarm:
|X| |_|
Standby Voltage:
|X| |_|
Charge Voltage:
|X| |_|
Install date:
Manufacturer date:
BPS #6 Batteries: Locaction AC Pwr Bkr:
| Battery Type: Sealed Lead Acid |
| Left |
| Right |
| Pass Fail |
| Battery Size: 2ea 12v |
| AH |
| AH |
| |_| |_| |
Load Voltage After 5 minute alarm:
Standby Voltage:
Charge Voltage:
Install date:
Manufacturer date:
Sprinkler Solenoid Information
| Riser ID |
| Location |
| Disconnected |
System Test and Inspections
| Visual |
| Functional |
| Comments |
| Control Panel |
| |_| |
| |_| |
| OK |
| Interface Equipment |
| |_| |
| |_| |
| OK |
| Lamps/LEDS |
| |_| |
| |_| |
| OK |
| Fuses |
| |_| |
| |_| |
| OK |
| Primary Power Supply |
| |_| |
| |_| |
| OK |
| Trouble Signals |
| |_| |
| |_| |
| OK |
| Disconnect Switches |
| |_| |
| |_| |
| OK |
| Ground Fault Monitoring |
| |_| |
| |_| |
| OK |
Alarm Notification Appliances Information
| Device types |
| Quantity |
| Manufacturer |
| Part # |
| Pass |
| Fail |
Horn/Strobe
| |X| |
| |_| |
Triple Units
| |X| |
| |_| |
Speaker Ceiling
| |X| |
| |_| |
Ext WP Strb/SPK
| |X| |
| |_| |
Ext WP Bell
| |X| |
| |_| |
Initiating and Supervisory Device Test and Inspection
Testing Method(s) Used: Functional
| Location |
| ID# |
| Device |
Type Visual Check Functional Check Factory Setting Measured Setting
| Pass |
| Fail |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| Location |
| ID# |
| Device |
Type Visual Check Functional Check Factory Setting Measured Setting
| Pass |
| Fail |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |X| |
| |_| |
| N/A |
| N/A |
| |X| |
| |_| |
| |_| |
| |_| |
| N/A |
| N/A |
| |_| |
| |_| |
| |_| |
| |_| |
| N/A |
| N/A |
| |_| |
| |_| |
| |_| |
| |_| |
| N/A |
| N/A |
| |_| |
| |_| |
| |_| |
| |_| |
| N/A |
| N/A |
| |_| |
| |_| |
| |_| |
| |_| |
| N/A |
| N/A |
| |_| |
| |_| |
Duct Detector was cleaned by Tech: ________________________________ Date: ________________
Sprinkler Solenoid Information
| Riser ID |
| Location |
| Reconnected |
Mass Notification Test
1. During Activation of all MN messages from ACU / LOC:
| YES |
| NO |
A. Fire/PA (when applicable) audible silenced
| |X| |
| |_| |
B. Amber (MN) strobes flash during MN message
| |X| |
| |_| |
C. White (fire) strobes turn off
| |X| |
| |_| |
D. Supervisory alarm sent to JBECC
| |X| |
| |_| |
Findings: N/A
2. ACU Tests:
| YES |
| NO |
A. Pre-approved messages programmed, labeled and activated:
| |X| |
| |_| |
| B. Verify no feedback using microphone for local live voice: |
| |X| |
| |_| |
| C. Common troubles at ACU unit puts FACP into trouble. |
| |X| |
| |_| |
Findings: ___________________________________
3. LOC (Remote panel/s) Test(s):
LOC #1
| YES |
| NO |
| A. Verify all messages can be activated and match chosen message |
| |X| |
| |_| |
B. Message nameplate on panel(s)
| |X| |
| |_| |
| C. Verify no feedback using microphone for live voice messaging: |
| |X| |
| |_| |
Findings: ____________________________________
4. JBECC MNS Operations:
| YES |
| NO |
A. Can activate all messages
| |X| |
| |_| |
B. Verify live voice can be received at building
| |X| |
| |_| |
Findings: __________________________________
FACP and Transmitter Status On Completion of Testing FACP is normal |_| yes |_| no Transmitter is normal |_| yes |_| no Status if not normal:_______________________________________________________ ________________________________________________________________________________________________________________________________________________________________________________________________________________________Tech__________________________________________________Date______________
Notification That Testing is Complete
| Yes |
| No |
| Person Contacted |
| Time |
| JBECC Monitor |
| |_| |
| |_| |
| Building Manager; CQ/OIC/NCOIC |
| |_| |
| |_| |
| JBLM Public Works (QC) |
| |_| |
| |_| |
| Joe Manfred |
| 1530 |
| AHJ/DPW (Notified) of any impairments |
| |_| |
| |_| |
N/A
Changes to System Since Last Testing
Changes to system since last test: NO|_| YES|_| Comments:
Facility has general heat and smoke devices not required in common spaces. These devices are not ITM’d and should be removed. NO|_| YES|_|
Device at FACP: NO|_| YES|_| and devices at BPSs: NO|_| YES|_| N/A|_|
System Components Operation
The following Component(s) not operational, (due to damage/removal or age of component):
1.)
2.)
Correction(s) made:
Date Corrected:
Inspected/Corrected by:
Number of Employees Testing:
Date System Restored to Normal Operation: Time: 1530
Sequence of Operation
1. All initiating devices report to Fire Alarm Panel and active warning devices.
2. Fire Alarm Panel reports to Radio Transmitter.
3. Radio Transmitter sends signal to base JBECC Dispatch Center.
4. Mass Notification System for use to broadcast emergency messages. (only use when MNS applies)
This Testing Was Performed In Accordance With Applicable NFPA Standards.
Name of Company Representative: George Mark Date:
Signature:
Name QC Representative: Joe Manfred Date:
Signature:
Name of JBLM Fire Department Representative:
Date:
Signature:
For “Name of Company” control only Building # Master FA Report 8-9-16