TE__1_PRS_11Jan2016.pdf
PDF 9 KB Posted
- Attached to
- Automatic Door Maintenance and Repair - JBLM Federal contract opportunity
- Solicitation number
- W911S8-16-R-0004
About this file
Technical Exhibit 1 - Performance Requirements Summary
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W911S8-16-R-0004-0003_(Extend_Offer_Due_Date).pdf | ||
| Daily_Q A_(W911S8-16-R-0004)-1June16.pdf | ||
| Daily_Q A_(W911S8-16-R-0004)-31May16.pdf | ||
| Site_Visit_Date_Change_-_Forthcoming_Solicitation_Amendment.pdf | ||
| W911S8-16-R-0004-0002_(Site_Visit).pdf | ||
| Daily_Q A_(W911S8-16-R-0004)-10May16.pdf | ||
| Daily_Q A_(W911S8-16-R-0004)-5May16.pdf | ||
| Wage_Determination_2005-2567_(Rev._21).pdf | ||
| W911S8-16-R-0004_(Conformed).pdf | ||
| TE__2_Deliverables_Schedule_11Jan2016.pdf | ||
| Auto_Doors_-_Performance_Work_Statement_April_2016.pdf | ||
| TE__3_List_of_Doors__11Jan2016.pdf | ||
| W911S8-16-R-0004-0001.pdf | ||
| TE__4_Monthly_Sched_11Jan2016.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL EXHIBIT 1
PERFORMANCE REQUIREMENTS SUMMARY
The Contractor service requirements are summarized into performance objectives that relate directly to mission essential items. The performance threshold briefly describes the minimum acceptable levels of service required for each requirement. These thresholds are critical to mission success.
Required Services Performance Standard Acceptable Quality Level Method of
Surveillance Periodic Maintenance (PWS para 5.1.1)
Work done in compliance with the latest codes in industry and safety standards, and AAADM guidelines.
No more than one (1) missed door during schedule periodic maintenance and emergency/over and above repair per month
Periodic Surveillance
Service Calls (PWS para 5.1.2)
Respond on-site within 8 working hours
Complete repair within 24 working hours.
One (1) hour deviation for response time per service call.
Two (2) hours deviation for completion time per service call
Periodic Surveillance
Parts & Materials (PWS para 5.5)
Item shall be new and meet or exceed quality of the original part/material.
0%. Material and parts report and invoice shall indicate the same or better quality
Periodic Surveillance
Monthly Reports (PWS para 5.6)
Submitted within 5 workdays of the following month
No more than one workday late 100% Inspection
CMR (PWS para 5.8) Shall be submitted electronically no later than 31 October of every year via the CMRA website with a follow-up confirmation email to the COR within 24 hours.
0%. Report entered correctly and timely through the CMRA website
100% Inspection