Attachment_10,_TAC_vista_201620463.pdf

PDF 51 KB Posted

Attached to
Repair / Renovate Building 1702
Solicitation number
W911S7-19-B-0001
Issued by

About this file

TAC Vista

View the file

Other files

File Type Posted
Bid_Abstract,W911S7-19-B-0001,_7_May_2019.pdf PDF
Drawing_C8182.38_Sheet_A2_of_7_Rev2.pdf PDF
Drawing_C8182.38_Sheet_M12_of_13_Rev1.pdf PDF
Attachment_1_Statement_of_Work,_1702_Revised.pdf PDF
Drawing_C8182.38_Sheet_M2_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_A6_of_7_Rev2.pdf PDF
Drawing_C8182.38_Sheet_M10_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_M3_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_A1_of_7_Rev2.pdf PDF
Drawing_C8182.38_Sheet_M9_of_13_Rev1.pdf PDF
Attachment_13_Questions_and_Answers_Bldg_1702_Renovations.pdf PDF
W911S7-19-B-0001-P00004.pdf PDF
Drawing_C8182.38_Sheet_M6_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_M13_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_A5_of_7_Rev2.pdf PDF
W911S7-19-B-0001-P00003.pdf PDF
Drawing_C8182.38_sheet_A6_of_7_Rev1.pdf PDF
Drawing_C8182.38_sheet_A2_of_7_Rev1.pdf PDF
W911S7-19-B-0001_Amendment_0002.pdf PDF
Drawing_C8182.38_sheet_A4_of_7_Rev1.pdf PDF
Drawing_C8182.38_sheet_A3_of_7_Rev1.pdf PDF
Site_Visit_Sign_In_Sheet.pdf PDF
W911S7-19-B-0001-Amendment_0001.pdf PDF
Attachment_12_Wage_Determination.pdf PDF
Wage_Determination_3-29-19.pdf PDF
Drawing_C8182.38_Sheet_MI_5_of_12.pdf PDF
Drawing_C8182.38_Sheet_F1_of_1.pdf PDF
Drawing_C8182.38_Sheet_MI_7_of_12.pdf PDF
Drawing_C8182.38_Sheet_M7_of_13.pdf PDF
Drawing_C8182.38_Sheet_M4_of_13.pdf PDF
Drawing_C8182.38_Sheet_A7_of_7.pdf PDF
Drawing_C8182.38_Sheet_M3_of_13.pdf PDF
Attachment_3,_FLW_Meter_Guidance.pdf PDF
Drawing_C8182.38_Sheet_MI_2_of_12.pdf PDF
Attachment_1_Statement_of_Work,_B1702.pdf PDF
Drawing_C8182.38_Sheet_E2_of_5.pdf PDF
Drawing_C8182.38_Sheet_MI_1_of_12.pdf PDF
Drawing_C8182.38_Sheet_A4_of_7.pdf PDF
Drawing_C8182.38_Sheet_A3_of_7.pdf PDF
Attachment_11,_Temp_IP_Network_Compliance_Statement.pdf PDF
Drawing_C8182.38_Sheet_MI_8_of_12.pdf PDF
Drawing_C8182.38_Sheet_M13_of_13.pdf PDF
Drawing_C8182.38_Sheet_M8_of_13.pdf PDF
Drawing_C8182.38_Sheet_M12_of_13.pdf PDF
Drawing_C8182.38_Sheet_A2_of_7.pdf PDF
Attachment_5,_JACE_(CoN).pdf PDF
Attachment_9,_Point_Schedule_Lonworks_BACnet_Niagara_2015-07-15.pdf PDF
Drawing_C8182.38_Sheet_MI_12_of_12.pdf PDF
Drawing_C8182.38_Sheet_MI_4_of_12.pdf PDF
Drawing_C8182.38_Sheet_A5_of_7.pdf PDF
Show 40 more

Latest 50 of 74 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOR OFFICIAL USE ONLY

Certificate of Networthiness (CoN)

Product: Schneider Electric TAC Vista 5.x

Cert# Request Type CoN Type Approval Expiration 201620463 Renew Enterprise 6/7/2016 6/7/2019 Mission Area Domain Functional Area Category

Business Installations & Environ Specialized Application

Description:

TAC Vista 5.x provides templates for creating logic sequences for Heating Ventilation and Air Conditioning (HVAC) devices via reusable function blocks and macros, to create new function blocks. These function blocks provide the logic sequence for each HVAC General Purpose Programmable Controller (GPPC) as defined by UFC 3 -470-01. A GGPC can be programmed and setup as a controller for different types of HVAC systems (e.g., rooftop unit, boiler, chiller). This product manages related electrical and mechanical systems, by monitoring and controlling environmental parameters such as temperature, humidity, and lighting, while optimizing energy usage. Vista’s capabilities include: cost allocation reporting; demand and supply energy management; and dynamic views of enterprise energy usage and cost. TAC Vista is also used to manage a wide range of capabilities including device connectivity, energy and environmental management, alarm management, data logging, time scheduling, remote monitoring, and system visualization.

TAC Vista 5.x is installed on a current Windows AGM build platform; the server and workstation are located on a segregated VLAN and cannot be accessed outside the domain. Access to TAC Vista is restricted to approved individuals. The users access the application via ISS/web (HTTPS) to view data stored on the server. TAC polls building mechanical devices (chiller, boiler, AHU) for status and displays on the Echelon IP router controller in a web interface. The controller is accessed through the Echelon IP Controllers in each building via HTTP. The application stores log files in a SQL database, and all data stays internal to the local enclave.

Facts:

• This is a renewal for Certificate 201518811.

CoN Link: https://portal.netcom.army.mil/apps/networthiness/_layouts/NetcomCON/rqstcon2.aspx?requestId=23120

Restrictions:

1. TAC Vista 5.x is restricted for use within certified and accredited networks and/or data centers having a current ATO.

POC: netcom.hq.networthiness@mail.mil /(520)538-1199

This Certificate of Networthiness is based on a trusted standardized platform, configured per FDCC. All patches and updates will be provided by the host network administrator (NEC or DECC) in accordance with all technical directives, mandates, and IAVM. This Certificate of Networthiness is no longer valid should the assessed configuration be significantly altered. Per Army Cyber Command guidance, all operating environment will implement HBSS capabilities. Upon expiration of this Certificate of Networthiness, this application must be reassessed to ensure it is still compliant with the GNEC architecture and is still networthy. Should this software version be upgraded prior to this expiration, the new version must be evaluated for networthiness.

Additional Comments:

X BRADFORD.DANIEL.1124817257

Signed on 2016-06-07T04:00:00Z

6/9/2016

Daniel Q. Bradford Senior Executive Service (SES), Deputy to the Commander / Senior Technical Director / Chief Engineer Network Enterprise Technology Command (NETCOM)

6/9/2016

File details come from the government source that posted it.