CONCRETE CEILING TO REMAIN CONCRETE CEILING TO REMAIN CONCRETE CEILING TO REMAIN CONCRETE CEILING TO REMAIN
B U
IL
D
IN
G
R E
P A
IR
I
N T
E R
IO
R F
IN
IS
H E
S C
O O
R D
IN
A T
IO
N
D A
T E
D A
T E
D A
T E
D E
S
IG
N E
D
D R
A W
N
C H
E C
K E
D
S U
B M
IT
T E
D
M M
U E
L L E
R
T T
A Y
L O
R
M M
U E
L L E
R
M M
U E
L L E
R
A P
P R
O V
E D
D A
T E
J D B
A L E
S C /E
D B
R E
V
IS
IO
N S
D E
S C
R
IP
T
IO
N D
A T
E D
IR
E C
T O
R A
T E O
F P
U B
L
IC
W
O R
K S
F O
R T L
E O
N A
R D W
O O
D
M
IS
S O
U R I
M A
D E
A P
P R 'D
SCALE
AS SHOWN
DATE
27 FEB 18
PROJECT NO:
DRAWING NO:
A4SHEET OF 7
A N
D D
E T
A
IL
S R
E F
L E
C T
E D C
E
IL
IN
G P
L A
N
4 0 4 8 16 FT8
SCALE: 18" = 1'0"
ADDITIONAL CONSTRUCTION
REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL SHEETS FOR
MATCH EXISTING HEIGHT OF EXISTING CEILING WITH NEW SUSPENDED CEILING SYSTEM
REFER TO ELECTRICAL LIGHTING PLAN FOR EXACT FICTURES
VERIFY NEW LOCATIONS WITH DESIGNERS
TO AVOID EXISTING SPRINKLER HEADS
ADJUST SUSPENDED CEILING GRID, LIGHTS, AND HVAC GRILLS SLIGHTLY AS NEEDED
REFLECTED CEILING PLAN
GENERAL NOTES
LEGEND:
2' X 2' LED FIXTURE
2' X 4' LED FIXTURE
1' X 2' SURFACE MOUNTED LED FIXTURE
SINGLE FACE EXIT FIXTURE
2 X 2 - 4 WAY DROP IN CEILING DIFFUSSER
2 X 2 - DROP IN CEILING RETURN AIR GRILL
ROUND EXHAUST GRILLE
4' LED WALL MOUNTED UPLIGHT/DOWNLIGHT
N O
R T
H
FOR ACTUAL NORTH
REFER TO SITE PLAN
PLAN NORTH
@ 8'0" ABOVE FINISH FLOOR IN ALL AREAS EXCEPT AS NOTED
PROVIDE 2 X 2 SUSPENDED ACOUSTICAL CEILING TILE
PAINT CONCRETE CEILING AND WALLS WITH THREE COAT SYSTEM IN ARMS ROOMS
@ 8'0" ABOVE FINISH FLOOR IN VESTIBULES, SHOWER ROOMS, AND JANITORS
" METAL CHANNELS AT 16" O.C.2
1" TYPE "X" GYPSUM BOARD ON 28
5PROVIDE
PAINT EXISTING GYPSUM CEILINGS IN STORAGE ROOM WITH TWO FINISH COATS
PROVIDE WATER BASED CATALYZED EPOXY COATING ON THE CEILING OF THE SHOWER ROOMS
DPW 03596-6J
M.0075377
C8182.38
@ 9'0" ABOVE FINISH FLOOR IN WEAPON BREAKDOWN SHOP AND CLASSROOM
PROVIDE 2 X 2 SUSPENDED ACOUSTICAL CEILING TILE
@ 8'6" ABOVE FINISH FLOOR IN THE BACK CORRIDOR ROOM 510
PROVIDE 2 X 2 SUSPENDED ACOUSTICAL CEILING TILE
IN THIS CORNER
PROVIDE FULL TILE
N O
T D
O
IN
G N
E W R
E S
T R
O O
M S A
N D C
L A
S S
R O
O M
/0
/2
A L
J D
B