Drawing_C8182.38_sheet_A2_of_7_Rev1.pdf

PDF 628 KB Posted

Attached to
Repair / Renovate Building 1702
Solicitation number
W911S7-19-B-0001
Issued by

About this file

Drawing C8182.38 sheet A2 of 7_Rev1

View the file

Other files

File Type Posted
Bid_Abstract,W911S7-19-B-0001,_7_May_2019.pdf PDF
Drawing_C8182.38_Sheet_A2_of_7_Rev2.pdf PDF
Drawing_C8182.38_Sheet_M12_of_13_Rev1.pdf PDF
Attachment_1_Statement_of_Work,_1702_Revised.pdf PDF
Drawing_C8182.38_Sheet_M2_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_A6_of_7_Rev2.pdf PDF
Drawing_C8182.38_Sheet_M10_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_M3_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_A1_of_7_Rev2.pdf PDF
Drawing_C8182.38_Sheet_M9_of_13_Rev1.pdf PDF
Attachment_13_Questions_and_Answers_Bldg_1702_Renovations.pdf PDF
W911S7-19-B-0001-P00004.pdf PDF
Drawing_C8182.38_Sheet_M6_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_M13_of_13_Rev1.pdf PDF
Drawing_C8182.38_Sheet_A5_of_7_Rev2.pdf PDF
W911S7-19-B-0001-P00003.pdf PDF
Drawing_C8182.38_sheet_A6_of_7_Rev1.pdf PDF
W911S7-19-B-0001_Amendment_0002.pdf PDF
Drawing_C8182.38_sheet_A4_of_7_Rev1.pdf PDF
Drawing_C8182.38_sheet_A3_of_7_Rev1.pdf PDF
Site_Visit_Sign_In_Sheet.pdf PDF
W911S7-19-B-0001-Amendment_0001.pdf PDF
Attachment_12_Wage_Determination.pdf PDF
Wage_Determination_3-29-19.pdf PDF
Drawing_C8182.38_Sheet_MI_5_of_12.pdf PDF
Drawing_C8182.38_Sheet_F1_of_1.pdf PDF
Drawing_C8182.38_Sheet_MI_7_of_12.pdf PDF
Drawing_C8182.38_Sheet_M7_of_13.pdf PDF
Drawing_C8182.38_Sheet_M4_of_13.pdf PDF
Drawing_C8182.38_Sheet_A7_of_7.pdf PDF
Drawing_C8182.38_Sheet_M3_of_13.pdf PDF
Attachment_3,_FLW_Meter_Guidance.pdf PDF
Drawing_C8182.38_Sheet_MI_2_of_12.pdf PDF
Attachment_1_Statement_of_Work,_B1702.pdf PDF
Drawing_C8182.38_Sheet_E2_of_5.pdf PDF
Drawing_C8182.38_Sheet_MI_1_of_12.pdf PDF
Drawing_C8182.38_Sheet_A4_of_7.pdf PDF
Drawing_C8182.38_Sheet_A3_of_7.pdf PDF
Attachment_11,_Temp_IP_Network_Compliance_Statement.pdf PDF
Drawing_C8182.38_Sheet_MI_8_of_12.pdf PDF
Drawing_C8182.38_Sheet_M13_of_13.pdf PDF
Drawing_C8182.38_Sheet_M8_of_13.pdf PDF
Drawing_C8182.38_Sheet_M12_of_13.pdf PDF
Drawing_C8182.38_Sheet_A2_of_7.pdf PDF
Attachment_5,_JACE_(CoN).pdf PDF
Attachment_9,_Point_Schedule_Lonworks_BACnet_Niagara_2015-07-15.pdf PDF
Drawing_C8182.38_Sheet_MI_12_of_12.pdf PDF
Drawing_C8182.38_Sheet_MI_4_of_12.pdf PDF
Drawing_C8182.38_Sheet_A5_of_7.pdf PDF
Attachment_2,_Certificate_of_Networthiness_(CoN).pdf PDF
Show 40 more

Latest 50 of 74 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B U

IL

D

IN

G

R E

P A

IR

I

N T

E R

IO

R F

IN

IS

H E

S

A N

D D

E T

A

IL

S F

L O

O R P

L A

N

N O

T E

S

C O

O R

D

IN

A T

IO

N

D A

T E

D A

T E

D A

T E

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

S U

B M

IT

T E

D

M M

U E

L L E

R

T T

A Y

L O

R

M M

U E

L L E

R

M M

U E

L L E

R

A P

P R

O V

E D

D A

T E

J D B

A L E

S C /E

D B

R E

V

IS

IO

N S

D E

S C

R

IP

T

IO

N D

A T

E D

IR

E C

T O

R A

T E O

F P

U B

L

IC

W

O R

K S

F O

R T L

E O

N A

R D W

O O

D

M

IS

S O

U R I

M A

D E

A P

P R 'D

SCALE

AS SHOWN

DATE

27 FEB 18

PROJECT NO:

DRAWING NO:

A2SHEET OF 7

4 0 4 8 16 FT8

SCALE: 18" = 1'0"

N O

R T

H

GENERAL NOTES

CONSTRUCTION NOTES

REFER TO MECHANICAL AND ELECTRICAL SHEETS FOR ADDITIONAL

PROVIDE TAPERED VINYL OR RUBBER MOLDING AT TRANSITION OF FLOORING MATERIALS

GENERAL NOTES CONTINUED

FLOOR PLAN

COMM

FOR ACTUAL NORTH

REFER TO SITE PLAN

PLAN NORTH

PAINT CONCRETE WALLS AND CEILING IN ARMS VAULT WITH THREE COAT SYSTEM

MISCELLANEOUS ITEMS

PROVIDE SOLID BACKING FOR WALL HUNG EQUIPMENT AND OTHER

UNLESS NOTED OTHERWISE

DIMENSIONS AT GYPSUM BOARD WALLS ARE TO STUDS

AND FINISHES

OR CONSTRUCTION - PATCH SHALL MATCH EXISTING CONSTRUCTION

PATCH WALLS, FLOOR, AND CEILING WHERE DAMAGED BY DEMOLITION

FROM MANUFACTURERS STANDARD COLORS

ALL FINISHES TO BE SELECTED BY CONTRACTING OFFICER

PRIOR TO APPLICATION OF CONCRETE SEALERS

SLAB SHALL BE CLEAN AND CLEAR OF OILS AND OTHER DELETERIOUS MATERIALS

'0

WITH SECURITY SCREEN

ROOF LADDER

PROVIDE ROOF LADDER WITH SECURITY SCREEN, REFER TO LADDER NOTE THIS SHEET

SPRINKLER

ENTRANCE

104 304 404 504

510 509409311 310209110 210

312 511

" = 1'0"4

3SCALE:

USE DOUBLE 20 GAUGE STEEL STUDS TIED TOGETHER AT DOOR OPENINGS

WALL TYPE NOTES:

WALL TYPES

A

WITH R-13 BATT INSULATION

" TYPE "X" GYPSUM BOARD EACH SIDE8

5WITH

" - 20 GAUGE METAL STUDS @ 16" O.C.8

A 111 412 512

A A

303203103

201 301

401 501

'9

JANITOR

OFFICE

OFFICE

OFFICEOFFICE

OFFICE

OFFICE 101

OFFICE 102

OFFICE 103

OFFICE 104

OFFICE 105

OPEN OFFICE

ENTRY

STOR

JANITOR

ARMS VAULT

OFFICE

OFFICE

OFFICE

OFFICE 111

OFFICE 112

OFFICE 113

OFFICE 114

OPEN OFFICE

ENTRY

ARMS VAULT

OFFICE

OFFICE OFFICE

OFFICE

OFFICE 107

OFFICE 108

OFFICE 109

OFFICE 110

OPEN OFFICE

ENTRY

ARMS VAULT

OFFICE

OFFICE

OFFICE OFFICE

OFFICE 101

OFFICE 102

OFFICE 103

OFFICE 104

OPEN OFFICE

VESTIBULE

ENTRY

ARMS VAULT

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE 101

OFFICE 102

OFFICE 103

OFFICE 104

OFFICE 105

OPEN OFFICE

VESTIBULE

ENTRY

M / W

OFFICE

M / W M / W M / W

OFFICE

OFFICE 115

CORRIDOR

A A

MEN WOMENWOMENMENWOMENMEN

BAY BAY

BUTTON BOLLARD

WIRELESS PUSH

TO INCLOSE SECURE AREA

TO MATCH EXISTING

EXTEND EXPANDED STEEL CAGE

B

A

'8

'1

23'6"

TO INFILL WHERE WALLS HAVE BEEN REMOVED AND IN CLOSE SECURE AREAS

PROVIDE EXPANDED STEEL CAGES IN THE BAY AREA TO MATCH EXISTING

MINIMUM LENGTH TO BE 24" - BEVEL INSIDE CORNERS

" X 4" HIGH VINYL BASE AT ALL INTERIOR WALLS8

1PROVIDE

PROVIDE WATER RESISTANT GYPSUM BOARD IN WET AREAS

AND WHERE LATH AND PLASTER WALLS WERE REMOVED

" TYPE 'X' GYPSUM BOARD WHERE REMOVED IN DEMOLITION 8

5PROVIDE

EXTENDED TO THE ROOF DECK ABOVE

WITH R-13 BATT INSULATION

" TYPE "X" GYPSUM BOARD EACH SIDE8

5WITH

" - 20 GAUGE METAL STUDS @ 16" O.C.8

A6

A6

A6A6

WITH TYPE 'A' WALL CONTRACTOR TO VERIFY AND MATCH WALL THICKNESS

IN FILL THE RESTROOM DOORS THAT ARE REMOVED ON THE BAY SIDE

ALL INTERIOR WALLS ARE TYPE 'A' UNLESS NOTED OTHERWISE

" X 4" HIGH RUBBER BASE AT ALL WALLS - MINIMUM LENGTH TO BE 24" - BEVEL INSIDE CORNERS8

1PROVIDE

TYPE 'B' WALL EXTEND TO THE UNDERSIDE OF THE ROOF DECK

AND BEHIND UTILITY SINKS IN JANITOR

USE WATER RESISTANT GYPSUM BOARD AT WET AREAS INCLUDING RESTROOMS, SHOWERS, BREAK AREA, PROVIDE 2 X 2 SUSPENDED CEILING SYSTEM IN ALL AREAS AS SHOWN ON SHEET A4

IN RESTROOMS, SHOWER ROOMS, OPEN OFFICES, CORRIDORS AND VESTIBULES

" X 4" VINYL BASE8

1" VINYL COMPOSITION TILE FLOORING WITH 8

1PROVIDE

REPAIR EXISTING WALLS AS NEEDED PRIOR TO TEXTURE AND PAINTING

AND TWO COATS LATEX SEMIGLOSS

TEXTURE WALLS WITH KNOCK DOWN FINISH AND PAINT WITH ONE COAT PRIMER

PAINT ALL NEW GYPSUM WALLS AND EXISTING WALLS UNLESS NOTED OTHERWISE,

PAINTED WITH THREE COAT SYSTEM

ON 1" X 2" POPLAR FRAME IN SMALL STORAGE ROOMS WITH EQUAL SPACING

PROVIDE FIVE ROWS OF 16" SHELVES OF PARTICLE BOARD OR MELAMINE WITH A PRE FINISHED EDGE

MOUNT PER MANUFACTURER'S RECOMMENDATIONS

CONTRACTOR TO FIELD VERIFY SIZE OF WINDOWS

ON STANDARD ANODIZED ALUMINUM TRACK WITH SIDE DRAW AT OFFICE WINDOWS (15)

PROVIDE 1" WIDE 0.030 THICK CURVED VINYL HORIZONTAL BLINDS

OR APPROVED EQUAL ON CONCRETE FLOOR IN ARMS ROOMS, JANITORS, AND REMAINING BACK BAY AREA

SUCH AS CRYSTAL SEAL OTC BY DAYTON SUPERIOR WITH NONSLIP SURFACE

PROVIDE 2 COATS OF A NON-YELLOWING ACRYLIC SEALER

WITH A PRE FINISHED EDGE IN JANITOR ROOM AT 5'6" AFF

PROVIDE ONE 9" X 2'0" SHELVE OF PARTICLE BOARD OR MELAMINE

A A

A A A

WHERE VESTIBULE DOORS WERE REMOVED INFILL NOTCH IN WALL GYPSUM BOARD AND METAL FRAMING

TYPE 'A' WALL EXTENDS THROUGH SOLID SURFACE TOP

LENGTH TO BE 9'0" WITH SILL AT +/- 4'0"

COUNTER SIMILAR TO ENTRY COUNTER DETAIL 3/A6

A6

SIMILAR

211 315 415 515

" X 4" VINYL BASE EXCEPT AS NOTED8

1IN ALL OFFICES AND CONFERENCE ROOM WITH

AND PILE FIBER OF NYLON 6 CONTINUOUS HOLLOW FILAMENT

PROVIDE NEW CARPET TILES OF MINIMUM 21 OUNCES PER SQUARE YARD PILE WEIGHT

BREAKROOM

A

A

B

B

'1

'1

11'1"

A3

CONFERENCE ROOM

B

B

C

11'10" 24'11"

OVER EXISTING WALL

AND R-11 BATT INSULATION

" TYPE "X" GYPSUM BOARD 8

5WITH

ON MOISTURE MITIGATION BARRIER

" - 20 GAUGE METAL STUDS @ 16" O.C. 2

C

AND PROVIDE A NONSLIP SURFACE

SEAL BACK BAYS CONCRETE WITH AN ACRYLIC SEALER

PAINT CONCRETE WALLS AND CEILING IN ARMS VAULT WITH THREE COAT SYSTEM

PAINT EXPOSED STEEL COLUMNS IN BAY AREAS WITH THREE COAT SYSTEM

TO MATCH EXISTING

AS NEEDED TO PROVIDE DOUBLE GATE

EXTEND EXPANDED STEEL CAGE

ON METAL FRAMING

" GYP BD 8

5WRAP COLUMN WITH

H

F F E E E E E

HEATER

WATER

PROVIDE NEW MOP SINK AND FIXTURE PER PLUMBING PLAN

DPW 03596-6J

M.0075377

TYPE 'C' WALLS EXTEND OUT PAST COLUMNS ON EXISTING WALLS

IN OFFICE AREA AND IN THE BACK BAY NEXT TO THE DOUBLE DOORS AS SHOWN ON SHEET F1

WITH GLASS DOORS AND 10# ABC FIRE EXTINGUISHER (FE) PER NFPA 10

PROVIDE SEMI-RECESSED MOUNTED STAINLESS STEEL FIRE EXTINGUISHER CABINET

C8182.38

STOR

JANITOR

OFFICE

OFFICE 106

NEXT TO DOORS INFILL PASS THROUGH WITH CONCRETE MASONRY UNITS TO MATCH ADJACENT

PAINT ALL METAL DOORS AND FRAMES WITH ONE COAT OF PRIMER AND TWO FINISH COATS OF GLOSS LATEX ENAMEL

STAINLESS STEEL SINK

8" X 22" X 33" 20 GAUGE

FOR SECURITY.

CAGE OVER THE LOWER PORTION OF THE LADDER TO 8’0” AND A HASP AND STAPLE

INTERMEDIATE CLIP ANGLES NOT OVER 48 INCHES ON CENTERS. PROVIDE A HINGED

THAN TWO 1/2 INCH DIAMETER EXPANSION BOLTS] AS INDICATED. PROVIDE

CLIP ANGLES RIVETED OR BOLTED TO THE STRINGER AND DRILLED [FOR NOT LESS

THE FINISHED WALL SURFACE WILL NOT BE LESS THAN 7 INCHES. PROVIDE HEAVY

INTO STRINGERS. INSTALL LADDERS SO THAT THE DISTANCE FROM THE RUNGS TO

WIDE, SPACED ONE FOOT APART, PLUG WELDED OR SHOULDERED AND HEADED

DIAMETER STEEL RODS FOR RUNGS. RUNGS TO BE NOT LESS THAN 16 INCHES

CFR 1910.27. USE 2 1/2 BY 3/8 INCH STEEL FLATS FOR STRINGERS AND 3/4 INCH

LADDER NOTE: FABRICATE VERTICAL LADDERS CONFORMING TO SECTION 7 OF 29 1

C

C

B

B

WEAPONS BREAKDOWN SHOP

WEAPONS BREAKDOWN SHOP

27'6"

ALIGN WALL WITH

THE END OF CAGE

SIMILAR

29 GAUGE METAL ACCESS PANEL WITH HINGE AND SCREW LOCKS

PROVIDE 2'0" X 2'0" FACTORY COLORED FINISH

PULL FURR OUT FAR ENOUGH TO COVER PIPING AND VALVES

B

B B

19'10"

PROVIDE NONSLIP SURFACE

AND WEAPONS BREAKDOWN SHOP

ON CONCRETE FLOOR IN BACK AREA CORRIDOR, BREAKROOM,

PROVIDE WATER BASED CATALYZED EPOXY FLOOR COATING

/0

/2

N O

T D

O

IN

G N

E W R

E S

T R

O O

M S A

N D C

L A

S S

R O

O M

A L

J D

B

2019-04-09T07:33:10-0500
BALES.JIMMIE.D.JR.1231309302