Exhibit_K_SVAD_CAPABILITIES_OVERVIEW_MSS_23_Nov_2016.pdf
PDF 7 MB Posted
- Attached to
- White Sands Missile Range Mission Support Services Federal contract opportunity
- Solicitation number
- W91151-18-R-0005
View the file
Other files for this federal contract opportunity
Show all 50
White Sands Missile Range Mission Support Services has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SVAD Facilities and
Capabilities Overview
Prepared By: Randy Brady
Organization: SVAD / WSTC
Title: Director
Date: 23 NOV 16
U.S. Army Test and Evaluation
Command
JERMAIN.M.COMPTON
Typewritten Text Exhibit K: SVAD Facilities and Capabilities Overview
JERMAIN.M.COMPTON
Typewritten Text
JERMAIN.M.COMPTON
Typewritten Text
Agenda
SVAD Organization Structure
SVAD Nuclear / Radiation Capabilities
SVAD Electromagnetic Capabilities
SVAD Applied Environment Capabilities
SVAD Laser Capabilities
Questions.
SVAD Organization Chart (1 of 2)
Nuclear Effects
Division
Division Chief, GS-14
27 Government
Personnel
20 Contractor
Personnel
Directorate
Staff –
Government
Personnel
Electromagnetic
Effects Division
Division Chief, GS-14
26 Government
Personnel
16 Contractor
Personnel
Applied
Environments
Division
Division Chief, GS-14
27 Government
Personnel
12 Contractor
Personnel
Fast Burst
Reactor
Director –
GS-14
5 Government
Personnel
1 Contractor
Personnel
High Energy
Laser Center
Director -
GS-14
7 Government
Personnel
32 Contractor
Personnel
Director
GS-15
Dep Director
GS-14
SVAD Director:
Deputy Director:
Environmental Effects
Division - Division Chief:
Electromagnetic Effects
Division - Division Chief:
Nuclear Effects Division
- Division Chief:
Reactor Branch
Office Chief:
HELSTF Branch
Office Chief:
Operation Support Branch
Branch Chief:
Test Services Branch
Branch Chief:
Electromagnetic Branch
Branch Chief:
DE&I Radiation Branch
Branch Chief:
Projects Branch
Branch Chief:
Semiconductor Support
Branch
Branch Chief:
Radiation Facilities
Branch
Branch Chief:
SVAD Organization Chart (2 of 2)
Nuclear / Radiation Capabilities
Co-Location: Nuclear & HPEM Capabilities
REACTOR
FACILITY
LIGHTNING
DSL & NSL
RTASSC
SOLAR FURNACE
LINAC
GRF
EL DORADO
PI 538
M & T HPD-II/HEMP
H-HEMP
Sensors Suite
DETEC-WB
HPM-NB
RS-105
DETEC-NB
MS 188-125
Targets Metrology
STL
Engineering
Test Officers
RRL
Combined
RCF
CXS
CBRN: Nuclear Weapons Effects
Gamma Dose Rate (GDR)
Gamma Total Dose (GTD)
Neutron Fluence (NF)
Nuclear Thermal Radiation
High-Altitude EMP (HEMP)
Source Region EMP (SREMP)
Nuclear Airblast
Combined Radiation Environments
Enhanced Low Dose Rate Sensitivity
Semiconductor Test Laboratory (STL)
Rapid Response Laboratory (RRL)
Radiation Tolerance Assured Supply and Support Center-Obsolescence &
Life-Cycle
Circuit Analysis / Design / Hardening
Radiological Evaluations
Radiation Shielding / Attenuation
RADIAC Characterization
ELDORADO
GRF Facility - GTD
HERMES-III SREMP & GDR
LINAC - GDR
Solar Furnace - Thermal
Semiconductor Test Laboratory
(STL)
Measures electrical parameters of all types of discrete, active and custom semiconductors
Rapid transfer system between the GRF facility and STL
Nine experienced test engineers
In 14 yrs. characterized and tested > 5,800 devices
― Mix Signal Memory
Teradyne A575 2 -Credence KALOS
Teradyne A585
Teradyne J750 (2)
Teradyne FLEX
Teradyne MicroFLEX
Credence Diamond10
3 - Credence AS3000
1 - Credence ASL3000RF
Rapid Response Laboratory with
Five Workstations
Five experienced test technicians
One experienced EE
>350 electronic devices characterized & tested
A575
FLEX
MicroFLEX
Radiation Tolerance Assured Supply and Support Center (RTASSC)
Radiation Tolerance Assured Supply and Support Center (RTASSC)
Life-cycle RT Monitoring &
Tracking: Monitor, track, and
Analyze Manufacturing design and process changes & new products
RT Device Acceptance or
Rejection
RT Engineering Solutions
DMSMS Engineering & Supply
Solutions
Third party Manufacturing &
Procurements
Established JEDEC Standard for
Long-term Storage (wafer/die and/or finished product)
Classified and Unclassified
Storage
Dry Nitrogen Storage
Remstar Storage
Prompt Neutron Fluence - Reactor
Reactor: prompt neutron fluence
IOC Aug 1964
Only DoD or DOE Capability, critical to Nuclear Survivability
Pulse: up to 6.5E13 n/cm2 (Si)@ 6” Steady state: up to 8 kW or 4.7E14/hr@ 6” Gamma Enhanced—E8 Rad(Si)/pulse
Operations >19000 since 1964
Systems: Abrams, Bradley, Paladin, STRYKER, FCS, SINCGARS, JTRS, MLRS/ATACMS, NLOS-LS, NBC
Detectors, EPLRS, FBCB2, SADARM, Minuteman, EFV, Trident, Satellites, B-52, GPS, LAV, Non-DOD: NASA, DOE, JPL, etc.
PI 538 Flash X-ray Simulator
Combined Environments: Neutron (reactor) and Gamma Radiation (PI 538)
Combined Environments
Outdoor Operation
Reactor In-cell Operations
PI 538 Flash X-Ray
Gamma Dose Rate Characteristics
Energy (total): 100 kJ
Energy (particle): 4.2Mev
Dose: 4.0 x 104 cGy (Si) @ faceplate
Dose Rate: 4 x 1011 cGy (Si)/s @ faceplate
Risetime (10-90%): 20ns
Pulse width (FWHM): 85ns
Repetition Rate: 4 shots/hr
Reproducibility: ±15%
E-beam Capability
Combined Environment Capability
High-Altitude Electromagnetic Pulse
Horizontally Polarized Dipole -II Facility The Horizontally Polarized
Dipole II (HPDII) simulator
Fast Risetime, Free-Field HEMP
Mobile Capability
Can Test at Remote Sites
Two Simulators available – RES1 and HAGII-C
Test >200 Systems – Required Back-Up and Mobile Capability to support various missions.
Patriot
VMMD
High-Altitude Electromagnetic Pulse
Advance Fast EMP Simulator (AFEMPS)
Minimum Test Volume (H x
W x D)
50 m x 50 m x 50 m
Test Area Electric Field
Uniformity ± 10%
Test Area Peak Electric
Field (min) 70 kV/m
Rise Time (10% - 90%)
1.2 ns – 1.8 ns
Fully MIL-STD 2169B/C
Compliant
On-Line – April 2012
Gamma Dose Rate Linear Electron Accelerator (LINAC)
LINAC is designed to simulate the gamma spike associated with a nuclear weapon detonation by producing high-intensity, short-duration pulses of high-energy electron radiation.
Cost-effective means of testing Piece-Parts and Nuclear Event Detection (NED) Design
Extremely Efficient / Quick Pulse Rates
Provides Gamma Total Dose and residual gamma dose environments on virtually any size item – Normally LRU or CCA.
Primarily for Transient Radiation Effects on Electronics (TREE) experiments
Verification tests of systems for gamma dose survivability.
Diverse – radiography, shielding experiments, calibration and operational testing of RADIACs
60,000 Curies of Co60
Gamma Total Dose Gamma Radiation Facility (GRF)
Gamma Total Dose
Enhanced Low Dose Rate Sensitivity
(ELDRS) Facility
Gamma dose simulation testing.
Dose rates between 5 and 0.001 cGy(Si/sec) in the direct beam with no attenuation.
Extended operation mode to fulfill the unique requirements of Space Radiation Environment - ELDRS tests.
Large Exposure Area for LRU & CCAs through manipulating the extenders.
Radiation Correlation
Radiation Correlation Facility (RCL) The Radiation Correlation Facility
(RCL) is used to provide radiation fallout field simulation. The fallout field is simulated using two small sources, a Cobalt-60 isotope (Co-60) source (which simulates the early fallout spectrum up to 4 hours and the late fallout spectrum +5 days) and a Cesium 137 isotope (CS-137) source (which simulates the mid time fallout spectrum 4 hours to 5 days)
IAW AEP-14.
Technical Data
• 75 mCi Cs-137
• 40 mCi Co-60
• 9 X 27 meters test area
• Co-located with Gamma Radiation
Facility (GRF)
Nuclear Thermal Facilities White Sands Solar Furnace
The White Sands Solar Thermal
Test Facility produces intense thermal radiation pulses to simulate the thermal radiation from detonation of a nuclear weapon
Performance Parameters:
Pulse Types:
Steady-State
Square Pulse
Nuclear Pulse
Max Fluence –Unlimited
Max Flux – 50 cals/cm2-sec
Target Area = 6 Inch Diameter
Quartz Lamp Thermal Facility
This Facility was part of the Tri-Service
Thermal Radiation Facility. nuclear weapon
Fully Operational at WSMR.
Conducted Test Support several times for the Navy Trident Program.
Performance Parameters:
Pulse Types:
Min Pulse = 1 Second
Max Pulse = 6 Seconds
Max Flux – 40 - 42 cals/cm2 /sec
Target Area = 12 Inch Square
Future Thermal Facility – FLARE Example
This Future Facility to correct Gap with current facilities with Army Nuclear
Major
IOC = 3rd Quarter FY18.
Performance Parameters:
Pulse Types:
Steady-State
Square Pulse
Nuclear Pulse
Max Flux – Threshold - 400 cals/cm2 /sec
Max Fluence – Threshold = 5 – 400 cals/cm2
Target Area = 10 Inch Square Threshold
Reqt.
Electromagnetic Capabilities
Electromagnetic Testing
Overview Sub-System – MIL-STD 461F/G
System – MIL-STD 464C
Understanding the E3 Evaluation Process
Requirements Defined by System E3 Review Board
E3 Experimental Design
E3 Design Consultation Services
One Stop E3 Test and Evaluation Shop
Three 72-Ton, 33’Dia. Turntables
One 72-ton Positioner
300 Ft. Tower
T-1E-1
T-2
E-3
EMI
Chamber
T-4
EMI
RE Test
Cell
MMW
UWB
E-4
ESD
E3 - EMRE Test Complex
T-3
PUHF
PP-SP
PPC1
PPC2
MIL-STD 464A/C, MIL-STD-461E and ADS-37A Compliant
Open-Air Testing
System Operated during Illuminations
Full coverage, Average and Peak Power
Entire Body Uniform Illuminations @ Full Threat
3 – 500 MHz for MLRS size system
10 kHz – 18 GHz for HMMWV size system
AM, FM, PM and CW Modulations
Localized Illumination @ Full Threat
500 MHz – 45 GHz
AM, FM, PM and CW Modulations
Three Separate 72-ton, 33’-dia. Turntable Sites
One 70-ton, hydraulic Positioner for Peak Power
Seven Simultaneous Test Capability
Transient and Injection
RS105
MIL-STD 188-125
Full Range of EMI tests in Anechoic Chamber
EMRADHAZ—HERF, HERO & HERP
ESD—Personnel, Helicopter and P-static
Very Large EM Shielded Test Cell
Radiated Emissions/EMI
Shielding Effectiveness
Interior Dimensions of 60’ L x 40’ W X 40’ H
E3 - EME Capabilities
Test Cell
Peak Power
T-4
AVERAGE POWER SUMMARY
Transmitter # 1: 3-30 MHz, 50 kW Amp, Dipole
Co-located with 72-ton, 33’-dia Turntable
Transmitter # 2: 8 kHz-30 MHz, 10 kW Amp, Strip-line
Transmitter # 3: 30-100 MHz, 50 kW Amp, Log Periodic, Co-located with 72-ton, 33’-dia Turntable
Transmitter # 4: 100 – 500 MHz, 32 kW Amp, Horn, Co-located with 72-ton, 33’-dia Turntable
500 kHz-3 MHz, 10 kW Amplifier 80-1000 MHz, 4 kW Amplifier
1-2.5 GHz, 2 kW Amplifier
Two 2-3 Amp through Combiner, 3.4-5.5 kW Output
7.3-18.2 GHz, 1.7-2.1 kW Amplifier
18-26.5 and 26.5-40 GHz, 40 W Amp Each
18-26.5, 26.5-41 and 38-45 GHz, 155 W Amp, Ea
T-4
T-3
T-2
T-1
Peak Power Bldg No. 1—Amplifier (3 Tetrodes)
1000 MHz, 175 - 240 kW, 12.5 - 125 μs
1 - 1000 pps
Automatic Tuning
Peak Power No. 2, 40’ x 8’ Conex
• Variable Frequency: 2.4 - 18 GHz, up to 40 kV/m
• 13 Magnetrons, all >125 kW, many 1 MW
• 1 - 2 μs or 350 ηs pulsewidths, fully automated
Peak Power No. 3, 40’ x 8’ Conex
• Variable Frequency: 1.2 - 12 GHz, up to 22 kV/m
• 13 Magnetrons, all 1000 kW, fully automated
• 1-2 μs or 350 ηs pulsewidths
Peak Power No. 4, SuperPuma, 26’ x 8’ Conex
• Variable Frequency: 20 GHz – 39 GHz
• 10 Magnetrons, all > 120 kW, up to 12 kV/m
• 1 - 2 μs pulsewidth, fully automated
SuperReltron Threat System
Six Tubes up to 70 kV/m across 4mx3m area@15 m
E4 10 kHz - 220 MHz, 10 KW Amp
E2 18 - 26.5, 26.5 - 42 & 38 - 45 GHz, each 155 Watts
Each Magnetron has 50 Selectable Frequencies
Peak Power Summary
MIL-STD 461A - G Compliant
Anechoic Chamber
Radiated Susceptibility
0.01 MHz – 45 GHz 200 V/m Intensity
Radiated Emissions, 3 MHz - 45 GHz
Conducted Emissions
Conducted Susceptibility
ESD
Helicopter— +400 & ±300 kV
Personnel— ±25 kV
P-Static
EMI Capabilities
PESD
HESD
RS103
RE102
Lightning
Simulates Direct Strike Lightning and Near Strike Lightning
MIL-STD 464A Compliant
Direct Strike “A” Component: 250 kA
Direct Strike “D” Component: 65 kA
Risetime = 2 μs, Pulsewidth = 20 μs (FWHM)
16m x 16m Test Area
Near Strike—180 kV/m
RS105 Facility
MIL-STD 461F Compliant
Test Volume: 1.2m x 1.2m x 1.2m
Peak Amp: >70 kV/m
Risetime: 2.0-2.5 ns, 10-90%
Pulsewidth—22-28 ns
Transient Capability
Directed Energy Weapons (DEW)
APT
HPM-UWB
IRA
PLVTS
CO2 Laser
HPM-NB
HPM-WB
UWB – 670-4300 MHz, 35kV/m @ 30m
WB – 200-6000 MHz, 9 bands & 125-280 MHz
NB – PUHF – 140-1000 MHz & 1000-1700 MHz
NB – 36 Magnetrons, 1.25-38.3 GHz
50 Selectable Frequencies/Magnetron
350,1000 & 2000 ns FWHM
5-30 kV/m@2m depending on Magnetron
NB – NBTS – 1-1.7 GHz, 10 pps
NB – SR System—670-3000 MHz, 10 pps
55kV/m @ 15m (4m x 3m), 0.35 & 1 µs FWHM
LASERS
CO2—10.6 micron, 1 kJ, 35 MW
Agile Laser—0.5 - 2.0 μm
Eye-Safe Laser—1.57 μm, 5 W
Advanced Pointer Tracker (APT): Radiometric, LASER Beam Director, Dynamic Tracking
Eye-Safe Agile
Applied Environments
Environmental Overview
Gas Chromatography
FUNGUS SOLAR RADIATION
TTF-ICE
VIBRATIONSTATIC FIRING
MIL-STD 810G Climactic Dynamics
Metallurgical
Microbiological Lab
Analysis of Materiel & Environments
Propulsion (100 Klbs of thrust)
Chemical Lab (ORELAP)
Fungus
Conformance Testing
Environmental Analysis
TTF: Climatic
105’Lx40’Wx50’H
35’Lx30’Wx20’H
20’Lx15’Wx10’H
ETA-II:
30’Lx22’Wx16’H
Multi-Purpose:
70’Lx24’Wx21’H
Portable :
25’Lx9’Wx6’H
Environment Capabilities
Significant and Complete MIL-STD 810 and ASTM Test Facilities
Climates
Temperature Test Facility (105’LX40’WX50’H) Multipurpose Chamber (70’Lx24’x21’H) Environmental Test Area II (ETA-II) Large Portable Test Facilities (25’Lx9’x6’H)
Mission Support Chemistry Laboratory Radiographic Laboratory, 4 MeV, 420 & 320 KeV Metallurgical Laboratory Microbiology Shock and Vibration Capabilities Propulsion Testing of Solid Propellant Rocket
Motors, 100K lbs of thrust
Climatic Test Capabilities
(MIL-STD 810G)
TTF:
105’Lx40’Wx50’H
35’Lx30’Wx20’H
20’Lx15’Wx10’H
ETA-II:
30’Lx22’Wx16’H
Multi-Purpose:
70’Lx24’Wx21’H
Portable Chambers
25’Lx9’Wx6’H
Dynamics Test Capabilities
Flight Level Vibration Test
Transportation Vibration Test
Pyroshock Test
Resonance Beam Shock
Vibration
Shock
Loose Cargo
MIL-STD 810G
Static Firing Stand
Metallurgical Lab Test Capabilities
Failure & Material Analysis
Of Metallic & Non-metallic
Non-Destructive Evaluation
Heat Treating Equipment
Filmless Radiographic System
RTF: 4 MeV, 420 and 320 keV x-Ray
Chemistry Lab Test Capabilities Conformance Testing
Hydraulic Fluids
Diesel Fuel
Breathing Air
Clean Room
Missile Propellants
Project Support (Centralized &
Field Work)
Missile Exhaust Gas Analysis
Explosives Analysis
Failure Analysis
Identification of Unknown
Samples
Analytical Services Tailored to
Customer’s Request
Gas Chromatography
Atomic Absorption Spectrometer
Laser Capabilities
Target Reflected Energy Measurement (TREM)
Ground Target Irradiance Measurement
(GTIM)
Hazardous Test Area (HTA)
50 ft Dia Vacuum Chamber
JHPSSL
Fully Equipped
Machine Shop Nuclear Hardened
Control RoomsCleaning Facility
DLWS 150 kW
HELSTF Capabilities
In-house Design and
Integration Support
PDR and CDR:
Requirements Flow
Down
Designs, Analysis and
Trades
Verification Method &
Data Products
Derived Requirements
Summary & Interfaces
Functional Flow
Software Flow
Diagrams
Integration and Testing
HELSTF Modeling
HELSTF Modeling
Calorimeter
Zircar Scatter Plate
Camera Location
Shelter for Personnel and Data Recorders
Supersonic Airflow for Targets
750 meter site Test Cell B
Test Cell 3
PLVTS
2 km site
Pulsed Laser Vulnerability Test System (PLVTS)
Red–on–Blue Survivability Testing
Lethality Testing
300 Meter Underground
Propagation Tunnel
Questions
File details come from the government source that posted it.