Attch_15_Test_Task_MultiRqmt.pdf

PDF 61 KB Posted

Attached to
Test Support Services
Solicitation number
W91151-12-R-0037
Issued by

About this file

Attachment 15 - Sample TAR Test Multi Requirement

View the file

Other files

File Type Posted
W91151-12-R-0037_Amendment_0003.doc DOC document
W91151-12-R-0037_Amendment_0002.doc DOC document
W91151-12-R-0037_Ammendment_0001.doc DOC document
TE_Z_USAOTC_SOP_G4_3_Uniforms2.pdf PDF
Attch_16_Base_Operations.pdf PDF
TE_A_CDRL_Page_4of4.pdf PDF
TE_A_CDRL_Page_4of4.pdf PDF
TE_Y_DID_A007_Sensitive_Items_Rpts.doc DOC document
Attch_6_Security_Clearances.doc DOC document
W91151-12-R-0037_Final_RFP.doc DOC document
Pre-Solicitation_Conference_Sign_In_Sheet.pdf PDF
Attch_3a_GFP.xls XLS spreadsheet
Attch_6_Security_Clearances.doc DOC document
TE_J_DID_A009_Technical_Manuals.doc DOC document
TE_F_DID_A005_Emergency_Contact.doc DOC document
TE_N_DD_Form_254.pdf PDF
W91151-12-R-0037_Final_DRFP.pdf PDF
TE_A_CDRL_Page_1of3.pdf PDF
Attch_8_Task_MultiRqmt.doc DOC document
TE_A_CDRL_Page_3of3.pdf PDF
TE_M_DID_A012_HAZMAT.doc DOC document
Attch_10_Techn_Base_Sample.doc DOC document
Attch_1_OTC_MAP.pdf PDF
Attch_11_Airborne_Tech_Svc.doc DOC document
TE_K_DID_A010_Software_Doc.doc DOC document
TE_E_DID_A004_Weekly_Report.doc DOC document
TE_G_DID_A006_Test_Validation_Rpts.doc DOC document
Attch_12_Airborne_Data.doc DOC document
TE_B_DID_A001_Monthly_Report.doc DOC document
TE_Q_USAOTC_Policy_CG_9_CCIR.pdf PDF
TE_L_DID_A011_Personnel_Status.doc DOC document
Attch_13_HAZMAT.xls XLS spreadsheet
Attch_5_Historic.xls XLS spreadsheet
TE_W_Acronym_List.doc DOC document
Attch_2_GFF.pdf PDF
Attch_3b_GFSoftware.xls XLS spreadsheet
TE_T_USAOTC_Policy_SOP_Safety.pdf PDF
TE_U_USAOTC_SOP_G4_7_Fire_Prev.pdf PDF
TE_P_Wage_Determinations.doc DOC document
TE_C_DID_A002_Quarterly_Briefing.doc DOC document
Attch_4_Inst_Catalog.doc DOC document
Attch_7_Base_Operations.DOC DOC document
Attch_9_Task_Limited_Req.doc DOC document
TE_H_DID_A008_Engineering_Reports.doc DOC document
TE_V_USAOTC_SOP_G4_6_Env.pdf PDF
TE_D_DID_A003_TIP.doc DOC document
TE_A_CDRL_Page_2of3.pdf PDF
TE_S_USAOTC_Policy_G4_3_Loaned.pdf PDF
TE_R_USAOTC_Policy_G6_1_IT.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Number Task Number xxxx – Multi-RequirementTest Attachment #15

NOTE: This sample Task Authorization Request (TAR) is provided to give interested vendors a more detailed understanding of potential test support requirements under this contract. No actual deliverables are expected in response to this TAR. Vendors should use the information in this TAR as a basis develop their technical approach.

1. GENERAL TEST INFORMATION: Unless specifically changed by this task order, the contractor performance shall be in accordance with the terms and conditions of the contract. If there is a conflict, the terms and conditions of the task order shall take priority.

1.1. BACKGROUND

a. Full name of test:

b. Test Location/Dates: Fort Knox, Kentucky Pilot Test: 17-22 August Record Test: 25 August-22 September

c. Classification: UNCLASSIFIED

d. System/Functional Description: The System Under Test consists of mounted and dismounted infantry troops connected via a family of internet platforms providing situational understanding in a variety of environments. It will provide Chemical, Biological, Radiological, and nuclear (CBRN) situational awareness and Detect to Warn (Detect to treat for biological detection and identification) via cooperative CBRN networks and reconnaissance. The system has similar survivability, mobility, communication, lethality, and transportability characteristics as the Mine Resistant Ambush Protected (MRAP). 1. Base Vehicle: Employs work stations for a crew of four (4) personnel. For self-defense, it employs a remote weapon station with a .50 cal machine gun that can be operated from within the vehicle when in an overpressure state. The system has a specialized overpressure and climate control system. The system employs a 400 ampere alternator to provide power to the vehicle and mission equipment. It has provisions inside and outside for the crew to carry personal equipment, basic loads of ammunition, rations, water, and Petroleum, Oil, and Lubrication (POL) products. The vehicle provides personnel survivability against specified threat munitions. Two MRAP versions will be used as base vehicles. MRAP CAT 1 is a Mine Resistent Utility Vehicle used for Urban Combat Operations. MRAP CAT 2 is a multi-mission platform capable of providing convoy escort and troop/cargo transport as well as ambulance and Explosive Ordnance (EOD) Combat Engineer operations. 2. Mission Equipment: Employs as GFE the following NBC sensor components and equipment. 3. Command and Control: The command and control capabilities are similar to those of the base vehicle. Navigation is provided by the Precise Lightweight Global Positioning System Receiver (PLGR), and the Vehicular Intercom system (VIC-3) provides interior communication. External communication is provided by Single Channel Ground/Airborne Radio System (SINCGARS). External data communication is provided through the Force Battle Command Brigade and Below (FBCB2) computer through the Enhanced Position Location Reporting System (EPLRS). Unique to the system is the central CBRN Sensor Processing Group (NBCSPG), which consists of Central Data Processing Unit (CDPU) computers with data storage capability, and printer. The NBCSPG processes alarm and identification information from the sensors, formats it into an NBC-1 or NBC-4 report, and sends the report to the FBCB2, which then transmits it outside of the vehicle to the appropriate location.

e. Safety/HUC:

(1) Human Use Committee (HUC) constraints and requirements: None identified at this time.

(2) Safety issues and concerns. Travel to and from the test site requires about one hour and is over a potentially dangerous mountain pass. On long duty days (more than 10 hours), personnel should travel in groups.

(3) Other safety issues and concerns IAW Section C, 1.3.5 (Hazardous Duty) of the contract. The following are elements of the test program which are anticipated to pose potential hazards in the course of test implementation activities. Actions should be considered to mitigate the risks associated with these hazards and should be considered in the development of the TIP.

- Radio Frequencies

- Mounts

- Brackets

- Lasers

- Power Interfaces

- Stimulants of CBRN Agents

- Batteries

- Head protection is required

- Blank Ammunition

- Battery charging station

f. Contracting Officer’s Representative:

g. Alternate Contracting Officer’s Representative:

1.2 SCOPE: During the IOTE, typical user soldiers will operate the SYSTEM to execute missions in accordance with (IAW) Operational Mode Summary/Mission Profile (OMS/MP), Threat Test Support Package (TTSP) and the Doctrinal and Organizational Test Support Package (D&O TSP). The IOT will consist of four 96-hour scenarios conducted over a 28-day period IAW selected portions of the OMS/MP. Conduct of the 96-hour scenarios will include 24-hour per day operations. Weekend scenarios are not anticipated. The primary focus will be the integration of the CBRN suite and the soldiers’ ability to use the complete system during daylight and darkness as well as in Mission-Oriented Protective Posture (MOPP) levels I through IV. Data will be collected on the integration of the CBRN suite into the MRAP base platform. Data will be collected on the crew’s ability to use the training to operate the SYSTEM in its intended environment. There will be two systems used for the test with an additional vehicle available for backup. Prior to start of the record test, soldiers will attend MRAP New Equipment Training (NET) for Common and CBRN specific missions. Test players will also be provided unit/collective Doctrine and Tactics Training (DTT). Following the training and prior to the record test there will be a 96-hour pilot test. Three complete crews will be trained. Crews will rotate during pilot and record testing as only two crews will be needed to man the Systems Under Test (SUT). Maintenance, to include recovery and management of the System Supply Package (SSP) will be performed by contractors. One Stryker-trained soldier team will be inserted during the first record test 96-hour scenario to provide for comparison of crew activities between the MRAP and Stryker configurations.

*NOTE: Be aware that Kevlar Helmets are required due to potential dangers associated with the firing range.

Additionally, personnel are required to don chemical protective gear during test execution as stimulants will be released on the test range. Personnel will be performing duties in a tactical field environment during ambient weather conditions and may be required to traverse rough terrain on foot.

1.3. TECHNICAL POINTS OF CONTACT:

Test Officer:

Technical Support Officer:

Personnel identified herein are constrained by the Performance Work Statement (PWS). All technical coordination shall be within the general scope of the contract and the work requirement. Technical coordination shall not result in any action that:

a. Constitutes an assignment of additional work outside Section C or the Government requirement.

b. Constitutes a change as defined in the contract clause entitled "Changes -- Cost-Reimbursement" (FAR 52.243-2 Alt I).

c. Changes in any of the expressed terms, conditions or specifications of the contract.

d. Interferes with the Contractor's right to perform the terms and conditions of the contract.

2. SPECIFIC TECHNICAL REQUIREMENT:

The contractor's TIP response shall describe the technical approach and methodology with associated labor and reimbursables for each of the below subparagraphs. Cost shall be separately identified by each month and segregated by fiscal years.

2.1 Instrumentation Engineering Development/Methodology Requirements

a. Point of Contact:

b. Period of Support: 16 April-28 August

c. Requirements:

NOTE: Instrumentation shall be installed on four (4) SYSTEMs: Three (3) MRAPS and one (1) Stryker. Only two MRAP SYSTEMs will be in test at any given time. The remaining MRAP SYSTEM will be prepped and ready for use if needed. The Stryker SYSTEM will utilize cage armor. Government provided MILES will be used to provide Real Time Casualty Assessment (RTCA) and Position Location (PL) of the test players during scenarios.

Anticipate up to 28 vehicles and 72 dismounted troops being tracked at any given time.

(1) Demonstrate your approach for providing systems with appropriate mounts, hardware, and cables to monitor and record the following:

[a] Video of surveyor, performing normal NBC detection and identification, while stationary and on the move to include position-location (PL) time tag.

[b] External video camera-recording systems to capture and record the actions of the Dismounted Warrior Support System (DWSS) while the SUT is stationary and moving.

[c] Video of manual sampling activity; i.e., digging and storing test specimens from within the SUT utilizing the rubber glove seals.

[d] Access and record the SYSTEM intercommunication system and provide microphones to capture non-intercom comments. Access and record the communication over the SYSTEM systems integrated radios.

[e] Equipment as appropriate to record the position location of each NBC marker flag as it is being emplaced. The position location of the placement of the marker flags shall be displayed on the Surveyor’s video camera-recording system.

[f] Two (2) wide lens cameras small enough to ensure non-interference with crew activities per SYSTEM to monitor and capture crew activities inside the vehicle.

[g] Multiplex or Quad recording machines may be used.

[h] Equipment, brackets, and cables to interface with, capture and record the digital message traffic of the on board SYSTEM radios.

[i] Equipment as appropriate for the video recording and playback of the Video Graphics Adapter (VGA) taps of the Commander and Surveyor station displays. Select the recording media that best accommodates resolution requirements.

[j] Provide thru-site video on the Stryker SYSTEM.

(2) Demonstrate your approach for providing equipment as appropriate to monitor and record the alarm data, both as input to and output from the on-board EPLRS system for the following on board systems. Each of these systems provides a chemical agent alarm to the soldiers. Your approach should capture and record their alarms so that data can be used by the OTC test team.

[a] JSLSCAD

[b] CBMS Block II

[c] ACADA

[d] METSMAN

(3) Travel as required for an engineering evaluation of the SYSTEM. Evaluation shall encompass form, fit and function of requested instrumentation support. Anticiapte travel as follows: One trip for five days to Yuma, AZ and one trip for three days to Aberdeen Proving Ground, MD.

(4) Demonstrate your approach for providing support to an Electromagnetic Interference/Electromagnetic Compatibility (EMI/EMC) Test, EMI/EMC testing shall be completed prior to the start of the Pilot Testing. How would you resolve any EMI/EMC issue(s) caused by Operational Test Command's Instrumentation Suites. The test should be conducted with the instrumentation suite powered on and with all appropriate cables connected.

NOTE: Paragraphs (6) through (9) below do not require responses in your technical approach, but are retained here to provide vendors a broader understanding of a fully implemented requirement and may be valuable in developing cost.

(5) Instrumentation Description Documentation: Provide the necessary certification documentation and specifications of each instrumentation device: what they do, mounting technique, etc., that will allow the Test Officer to obtain an ATEC certification of the Instrumentation Suites.

NOTE: Vehicle power may not be utilized for instrumentation elements.

(6) Provide the following documentation:

[a] Informal weekly status reports

[b] Monthly progress reports

[c] Instrumentation Description Documentation

(7) Perform certification and ground truth test to confirm that instrumentation provides the expected data, instrumentation is not intrusive, and the data is delivered in a format useful to the customer or evaluator.

Certification includes the items that are non-developmental.

(8) Provide a Certification Report describing certification test results.

(9) Provide mounts, cables, brackets and other systems needed to support the use of items discussed in paragraph 2.3.

d. Milestones/Deliverables:

NOTE: The dates listed are intended to give interested vendors an idea of a typical timeline for a test event.

Proposers are not expected to provide any of these deliverables or to respond to these milestones.

DATE EVENT/REQUIREMENT/DELIVERABLE RESPONSIBILITY

TBD Apr Travel for engineering evaluation of systems under test TSC

TBD May Travel for Form, Fit, and Function TSC

2 Jun Deliver Instrumentation Description Documentation TSC to the Government

28 Jun Demonstrate Instrumentation Suite TSC

14 Jul Deliver Certification Report TSC

24 Jul Complete Coverage test TSC

3 Aug Coverage Test Report Due TSC

TBD Travel to participate in EMI/EMC certification TSC

16-26 Aug Travel to support Pilot Test TSC

2.2 Data Management Requirements.

a. Point of Contact:

b. Period of Support: 25 January-5 October

c. Requirements:

*Note: New Equipment Training events listed at paragraph c.2.c.(16 ) of this document will require minimal support. Anticipate full time requirements to commence not earlier than 23 May.

(1) Attend test planning meetings, providing technical input to briefing slides and discussions.

(2) Provide weekly reports.

NOTE: Paragraph (3) below does not require a response for the technical approach, but is retained here to provide vendors a broader understanding of a fully implemented requirement.

(3) Provide Information Assurance Security Officer (IASO) services. Required level 1 training is available online and can be provided by OTC G6. The IASO will coordinate all documentation with the Government ORSA.

[a] Develop an approved accreditation plan.

[b] Monitor information technology resources (ITR) during test events to ensure no unauthorized users/computers obtain access to event data and/or networks.

(4) Demonstrate your approach for developing data forms and form instructions to be used for capturing the data detailed in the following paragraphs.

(5) Demonstrate your approach for establishing and providing:

[a] A program of instruction (POI) for data collection training. This should include developing and publishing a data collector handbook.

[b] Control plans for data collection procedures at the test site.

[c] Safety measures and operating procedures for data collection personnel as required.

[d] Documentation of environmental controls and procedures at test site.

[e] Training data collectors on forms, data collection procedures, safety measures, control procedures and quality control of data.

[f] Input to the validation of the test database with dummy data. This will involve generating 25 sample records for each hard-copy form and running a complete end-to-end data reduction of these sample records prior to

OTRR 2.

[g] Data collection quality control and accountability of Manpower and Personnel Integration (MANPRINT), Reliability and Maintainability (RAM) and performance data for both pilot and record tests.

[h] Methodology to segregate alarm data from the different on board systems listed in paragraph 2.1.c.(2) for evaluation and scoring.

[i] Procedures for transferring, reducing, and reporting of all data collected.

[j] Applications that convert, merge, extract and create views of the data to assist in the data reduction and review processes.

[k] Procedures to provide quick review of RAM, Performance, MANPRINT and survey data.

(6) Demonstrate your approach for providing support for pre-test activities on data management, collection and reduction processes prior to test execution with ramp up exercises to validate training and performance demonstrations with practical exercises to prepare for data collection.

(7) Demonstrate your approach for establishing and maintaining an on-site data library for tracking of all data flowing into and out of the data management cell. This should include procedures for maintaining all test data and manual documentation. Typical documentation could include, test reference documentation such as collection requirements, training plans, system description documentation, doctrine and organizational support packages, control plans, and other test related reference materials and items. Paper-based products received (surveys, questionnaires for example) shall be transferred to digital images for archival to electronic media.

(8) Demonstrate your approach for collecting Performance, MANPRINT, and RAM data; instrumented data files, and SYSTEM subsystem electronic data files. Ensure quality of these files. Data will be collected on each SUT, as well as in the Green, Red, and White cells. Subsystem data files will be harvested at the end of each test scenario and provided to the data center.

NOTE: Paragraphs (9) through (17) below do not require responses for the technical approach, but are retained here to provide vendors a broader understanding of a fully implemented requirement.

(9) Video recorded interviews shall be conducted with selected test players at the end of each scenario.

(10) Establish a forward data operations cell to harvest and perform quality control of data prior to forwarding it to the data management cell.

(11) The TSC is responsible for the completeness of all data collected and for the validation of data in accordance with the approved test design.

(12) All manual data shall be entered into Microsoft (MS) Access.

(13) Data reduction to Level III data shall be completed within 24 hours after data collection. After data entry and final quality control check, all data shall be made available on automated systems to allow the Test Analyst and other personnel to perform essential data review. Test Analyst will review, approve and release data to the Data Authentication Group (DAG) members for review and inquiry.

(14) Develop a group interview plan based on guidance from the Government ORSA. Conduct group interviews.

(15) Transcribe MANPRINT data from group interviews.

(16) Attend New Equipment Training (NET) at Fort Hood, Texas, and fill out the training activity record form provided by the Government ORSA. Enter data from this form into the MANPRINT database and email the database to the ORSA daily. Anticipate training to be at Ft Hood. Draft training schedule is as follows:

• Field Level Training – 1 Feb – 3 Mar

• Hand Off – 17 Mar

• OPNET Training – 18 Mar – 27 May

• DTT – 3 – 25 June

• TADSS (virtual crew trainer) training/Issue – 28 – 30 June

(17) Perform backups of all data twice each day.

(18) Demonstrate your approach for providing support to the Data Authentication Group (DAG) chair for DAG member training, data authentication, and anomaly investigations and resolution to the scoring conference committee members. Your approach should address the following actions.

[a] Develop DAG viewing screens and provide procedures for electronic data authentication for inclusion into the Government’s DAG SOP. Support shall consist of recording details of data anomalies, performing investigation and resolution of data anomalies, tracking Request for Information (RFI) items, and assist in the preparation of DAG minutes.

[b] Develop data displays for presenting Performance, RAM and MANPRINT data to the DAG. Build summary tables and graphs for presenting the electronic data to the DAG. Populate these displays and summaries with data as the test progresses. Provide the results to the DAG chair.

[c] Provide monitoring of the DAG area to facilitate scoring of data by DAG and RAM Scoring Conference (RSC) members. This task shall require DAG/RSC technical knowledge as well as daily and ongoing communication with the ORSA and data managers.

[d] Provide final authenticated level III test databases and data dictionaries formatted for distribution.

Databases shall be submitted to the government no later than two (2) days after the final DAG meeting. Required media for electronic deliverables is digital video disk (DVD) to include cases and proper labels.

NOTE: Paragraphs (19) through (22) below do not require responses for the technical approach, but are retained here to provide vendors a broader understanding of a fully implemented requirement.

(19) Archive test data for delivery to the Government.

[a] Scan Raw Data Forms: Verify the scanned copy is readable and an exact copy of the original. Save the scanned forms and make them retrievable as if they were stored in paper form (manila folders). Once the verification process is completed and with approval from the ORSA, the paper forms are to be shredded. Electronic copies shall be provided as Adobe Acrobat files.

[b] Video Footage: All video shall be provided in digital format.

[c] Electronic/Digital Records: If the document is received electronically or in digital format, then keep it that way. No need to print the document for archiving - it can be archived in electronic format.

[d] Briefings: Keep in electronic format. No need to print the document for archiving - it can be archived in electronic format.

[e] Signed Word Documents: At a minimum, keep the signature pages in paper form and the rest of the document electronically.

[f] When archiving data, keep test planning files separate from raw data files; for example, use separate disks.

(20) Computers, instrumentation, and other Information Technology supporting the test shall be compliant with Army policies. (DIACAP, DITSCAP, net-worthiness.)

(21) Data personnel may be required to drive High Mobility Multipurpose Wheeled Vehicles (HMMWV) and shall be scheduled for training if not previously certified. Night driving is required due to the continuous 24-hour operations planned during test conduct. Data personnel shall be night vision device (NVD) qualified.

(22) Perform a test site communication coverage test. Contractor shall confirm that the planned test areas have effective radio coverage. Prepare and conduct two coverage tests. Provide a combined coverage test report not later than ten working days after the second test completion.

d. Milestones/Deliverables:

NOTE: The dates listed are intended to give interested vendors an idea of a typical timeline for a test event.

Proposers are not expected to provide any of these deliverables.

DATE EVENT/REQUIREMENT/DELIVERABLE RESPONSIBILITY

TBD Attend test planning meetings TSC

1 Feb - 27 May Attend NET (Fort Hood) TSC

21 June Databases and forms provided to TSC Govt TT

3-25 June Unit’s Doctrinal Tactics & Techniques Training Govt TT

20 June Conduct end-to-end data run with dummy data TSC

22 June OTRR 2 Govt TT/TSC

28 June Provide IA Guidance OTC (G6)

1 July Forms Instructions TSC

6 July Provide Information Assurance

Compliance Statement TSC

6 July Provide accreditation plan for ITR TSC

8 July Databases Due TSC

8 July Group Interview Plan TSC

15 July Data Collector Handbook TSC

3 Aug Test Team Deploys to Test Site Govt TT/TSC

14 Aug Data Collector Training Complete TSC

17-22 Aug Pilot Test Govt TT/TSC

23 Aug Pilot Test RSC/DAG Govt TT/TSC

24 Aug OTRR 3 Govt TT/TSC

25 Aug-22 Sep Record Test Govt TT/TSC

25 Sep Record Test RSC Govt TT/TSC

25 Sep Record Test DAG Govt TT/TSC

26 Sep Database validation complete Govt TT/TSC

28 Sep Redeploy to Fort Hood Govt TT/TSC

3 Oct Provide input for Lessons Learned TSC

3 Oct Provide input for After Action Review TSC

5 Oct Provide data for archives TSC

2.3 Instrumentation Requirements (other than engineering development).

a. Point of Contact:

b. Period of Support: 20 July-28 September

c. Demonstrate your approach to:

(1) Install, operate and maintain instrumentation on four (4) SUTs as described in paragraph 2.1.

(2) Install, operate and maintain Government provided MILES for up to 28 vehicles and 72 dismounted troops during pilot and record test phases. Equipment and manpower resources are required at test site not later than two weeks prior to the start of pilot test.

(3) Provide equipment as appropriate to facilitate the downloading, display, and archiving of all instrumentation data within 12 hours after completing each test iteration.

(4) Provide the equipment necessary to monitor and record the temperature, humidity and air quality inside the crew compartment of the SYSTEMs. Air quality will include monitoring for carbon monoxide, carbon dioxide and oxygen levels. The recorded data shall consist of tabulated time tagged concentration values in units of percent (%). Data sampling rate shall be once per second.

(5) Install, operate and maintain all the instrumentation during the certification test, demonstration, coverage test, pilot and record test. De-install the instrumentation upon the completion of the record test.

Installation, de-installation and checkout periods for the instrumentation shall be coordinated with the Test Team.

(6) De-install all instrumentation at the conclusion of the final test scenario.

d. Milestones/Deliverables:

NOTE: The dates listed are intended to give interested vendors an idea of a typical timeline for a test event.

Proposers are not expected to provide any of these deliverables or to respond to these milestones as part of their proposals.

DATE EVENT/REQUIREMENT/DELIVERABLE RESPONSIBILITY

NLT 14 Aug Instrumentation equipment installed TSC

17 Aug-22 Sep Test Events TSC

23-26 Sep De-install instrumentation TSC

2.4. Logistics Requirements.

a. Point of Contact:

b. Period of Support: 1 April-5 October

c. Requirements: All logistics requirements and resources are allocated and issued based on availability.

(1) Demonstrate your approach for providing logistics support to the test team, including but not limited to receipt, turn-in (as needed), storage, and issue expendable supplies and equipment to test team members as needed on a 24-hour basis during testing.

(a) Your approach should include accountability and control procedures, inventory processes, shipping, and receipt of supplies and materials as detailed below.

(b) Consolidated logistical support will be required in the following areas:

[1] Motor Pool Operation (dispatch, control, security, etc), sensitive items, and equipment

[2] Receive all Government Furnished Property (GFP)

[3] Maintain accountability and control of all items within the test team.

[4] Store and secure NVDs, supplies, equipment, and blank ammunition

[5] Point of contact for required services, fuel, power issues, facility maintenance, water, etc.

[6] Check the availability of GFP and equipment when required.

[7] MILES receipt and property accountability. Contractor shall be prepared to store MILES equipment between test scenarios.

[8] At the conclusion of the test, assist the test team in closure of the test site and the turn-in of all issued GFP.

[9] Shipping of MRAP equipment, 20 crates/pallets to Fort Knox, KY, as follows:

Dimensions Weight 42X36X24 652 42X36X24 652 35X24X41 570 45X42X19 969 46X26X32 900 47X32X22 756 49X36X31 546 56X46X61 2498 68X39X47 1126 72X55X51 1000 48X40X68 1956 48X40X68 1956 48X40X68 1956 48X40X52 1400 48X40X52 1400 49X22X42 292

37X30X40 274 44X27X32 546 48X40X32 565

(c) The Contractor’s plan shall address all property/equipment identified as Individual type property (ITE) and will include sensitive items like radios, night vision devices, and computer equipment (Laptops and Desktops) etc. These items shall be signed for and accounted for in accordance with the approved Property Control Plan

(PCP).

(2) Demonstrate your approach for providing operational support to the test operations cell to support 24 hours daily during the pilot and the record tests to include radio communications center and visitor control center.

The following should be considered.

(a) Coordinate with other test members and agencies for operational requirements pertaining to data collection and daily test events.

(b) Maintain a digital log of daily test events and back up this data to an external device daily.

(c) Provide input to briefings on test operations and test documentation as required.

(d) Provide input to the test report on Test Execution/ Operations as required. Ensure that all test events are in accordance with (IAW) with the test plan and all operations are conducted in a safe manner.

(e) Provide a VIP Van Operator.

(f) Establish access control of test site in conjunction with the government test team to include control plans for setting up the test site, ensuring safety, and 24-hour access control to include days between test scenarios.

(g) Design, provide, issue and control test team and visitor badges and ensure that only authorized or escorted personnel are admitted into test site areas. Maintain a visitor log and a test badge log to control issue and turn-in of badges.

(3) Provide on-site maintenance and repair support for OTC equipment during all phases of test execution.

d. Milestones/Deliverables:

NOTE: The equipment listed below is intended to give interested vendors an idea of support required for a test event. Proposers are not expected to respond to this list.

Provide the following Government Furnished Property (GFP). All items to be issued on 9 Aug or as otherwise indicated below.

Item Description Date/Quantity

Trailer, Triple Wide (FTC) 02

Expenses $3,500 01

ISU 90 Storage Container 01

Base Station SINCGARS Radio Set w/antenna 01

Base Station, Hand Held Radio w/antenna/repeater 01

Commercial Hand Held Radio w/battery/holster 14

Charger, Commercial Hand Held, 6 unit 03

Wet Weather Gear (pants/jacket) 13

Action Packers 05

Night Vision Goggles, AN/PVS-14 w/2 spare batteries for each 16

Wrecker, 5 Ton 01

VIP Bus 01

HMMWV, 4 door w/SINCGARS 04

HMMWV, 2 door w/SINCGARS 08

Generator, dual purpose, 30KW 03

Generator, dual purpose, 15 KW 03

Global Positioning System, Handheld 07

Helmet, Kevlar with chin strap 30

Stopwatch, Digital 06

Weather Station, Portable 01 (capable to record barometric pressure, wind speed and direction, humidity)

Fax Machine (at test site) 15 Aug /01

Copier, Large w/maintenance support (at test site) 15 Aug/01

Clocks, Office 05

Coffee Pot, 12 cup 05

Microwave Oven 10

Refrigerator, 16 cu ft 05

Shredders, large, medium use 02

Tables, six foot 10

Chairs 30

Fire Extinguisher, 5 lbs, all purpose 05

Trash Cans, 33 Gallon 10

Trash Cans, Office 12

Light Sets, 150 ft 03

Jug, insulated, 5 gallon 10

Ice Chest, 50 quart capacity 16

Test Team Uniforms, DAC 15

Parka, Wet Weather, DAC 10

Engineer Tape, 90 foot roll 03

Duct tape, 120 foot roll 01

Chem Lights, Amber, case 02

Chem Lights, Red, Case 02

Chem Lights, Green, Case 02

Chem Lights, Blue, Case 02