11B5140006_-_CABINET_I-J_ASSEMBLY.pdf
PDF 116 KB Posted
- Attached to
- MWMSS Type I and Type II Cabinet Sets Federal contract opportunity
- Solicitation number
- W9098S19T0094
About this file
11B5140006_Cabinet_I-J_Assembly
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 19T0094-0001_Released.pdf | ||
| Attachment_0001_-_PRICE_MATRIX_19-T-0094.xlsx | XLSX spreadsheet | |
| 11B5091020_-_CABINET_C_TOP_CABINET_ASSEMBLY.pdf | ||
| 11B5190645_-_CABINET_F_ASSEMBLY.pdf | ||
| 11B5091067_-_CABINET_B_TOP_CABINET_ASSEMBLY.pdf | ||
| Attachment_0003_CDRL0002_(Product_Warranty_Information)_v1.pdf | ||
| 19T0094_Released.pdf | ||
| 11B5091048_-_CABINET_C_BOTTOM_CABINET_ASSEMBLY.pdf | ||
| 11B5040003_-_CABINET_A_ASSEMBLY.pdf | ||
| 11B5040018revA_-_CABINET_W_ASSEMBLY.pdf | ||
| 11B5091047_-_CABINET_B_BOTTOM_CABINET_ASSEMBLY.pdf | ||
| 11B5190652_-_CABINET_G_ASSEMBLY.pdf | ||
| Attachment_0002_CDRL0001_(Commercial_Manuals_&_Copyright_Release)_v1.pdf | ||
| 11B5190656_-_CABINET_F-G_COUNTER_TOP.pdf | ||
| 11B5040015revB_-_CABINET_E_ASSEMBLY.pdf | ||
| 11B5040012_-_CABINET_D_ASSEMBLY.pdf | ||
| 11B5040021revA_-_CABINET_X_ASSEMBLY.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
45.37
30.00 30.00
10 3X
27.75
60.00
30.00
NOTES
1. APPLICABLE STANDARDS/SPECIFICATIONS:
A. ASME Y14.100-2004
B. ASME Y14.5-2009
2. IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF SUPPLY
HEREON IS NOT TO BE CONSTRUED AS A GUARANTEE OF PRESENT
OR CONTINUED AVAILABILITY AS A SOURCE OF SUPPLY FOR THE
ITEM DESCRIBED ON THE DRAWING.
3. VENDOR PART NUMBER(S) ARE FOR REFERENCE ONLY. DRAWING
SPECIFICATIONS AND DIMENSIONAL REQUIREMENTS SUPERCEDE
VENDOR PART NUMBER(S) AND/OR CATALOG CALLOUTS.
4. DOOR NOT SHOWN FOR CLARITY.
5. SOME ITEMS MAY NOT COME PRE-INSTALLED.
6. CABINET I-J ASSEMBLY AS SHOWN MUST BE DIS-ASSEMBLED ONLY
TO THE EXTENT REQUIRED TO MEET REQUIREMENTS OF ALTERED
ITEM DRAWINGS 11B5190776 - CABINET I-J COUNTER TOP,
MODIFIED; 11B5190754 - CABINET I HOUSING, MODIFIED,
11B5190755 - CABINET J HOUSING, MODIFIED; 11B5190769 - CABINET
SHELF J1 ASSEMBLY; 11B5190768 - CABINET J BOTTOM PAN ASSEMBLY
AND RE-ASSEMBLED AS ITEM 11B5140005.
7. REPLACEMENT PARTS ARE NOTED IN COMPONENT LIST AND ARE
FOR REFERENCE ONLY.
REVISIONS
LTR NOR NUMBER DATE APPROVED
- NOR 739-0001-001 2014-04-25 PMS
SUGGESTED SOURCE OF SUPPLY
PART
NUMBER
VENDOR DATA
NAME & ADDRESS CAGE
CODE
VENDOR
PART NO. DESCRIPTION
11B5140006
STANLEY VIDMAR STORAGE TECHNOLOGIES
11 GRAMMES ROAD
ALLENTOWN, PA 18103
800-523-9462
34004 P001591C-03 AND
P001591C-04
(2) CABINET HOUSING WITH SHOCK FEATURE,
SHOCK BAR, NO PALLET FEET FEATURE, AND
MOBILE BASE FEATURE.
SALIENT FEATURES
MUST BE INDUSTRIAL QUALITY
CONFIGURATION CONJOINED CABINETS WITH 8 DRAWERS, 1 SHELF, 1
COUNTERTOP, 1 DOOR, AND 4 CASTERS
SHELF ADJUSTMENT
THE SHELVES SHALL BE CAPABLE OF BEING MOVED
UP AND DOWN IN 1-3/4" OR LESS INCREMENTS OVER
A MINIMUM OF 75% OF THE CABINETS SHELF
STORAGE HEIGHT
SHELF WEIGHT CAPACITY WHEN INSTALLED IN THE HOUSING, SHELVES SHALL
HAVE A MINIMUM WEIGH CAPACITY OF 1000 POUNDS
BATTEN ADJUSTMENT
THE BATTENS SHALL BE CAPABLE OF BEING MOVED
UP AND DOWN IN 1-3/4" OR LESS INCREMENTS OVER
A MINIMUM OF 75% OF THE CABINETS STORAGE
HEIGHT
DRAWER WEIGHT CAPACITY WHEN INSTALLED IN THE HOUSING, DRAWERS SHALL
HAVE A MINIMUM WEIGH CAPACITY OF 400 POUNDS
DROP TEST
SHALL BE CAPABLE OF SURVIVING A 6" FLAT DROP
WHILE SECURED TO A PALLET WITH 60 POUNDS OF
SECURED WEIGHT IN EACH DRAWER, 75 POUNDS OF
SECURED WEIGH ON EACH SHELF, AND 100 POUNDS
OF SECURED WEIGHT ON THE BOTTOM PAN/FLOOR
OF THE SHELF CABINET WITHOUT ANY PERMENANT
DAMAGE
RAIL IMPACT TEST
SHALL BE CAPABLE OF SURVIVING AN 8 MILE AN
HOUR RAIL IMPACT FORWARD AND BACKWARDS
WHILE SECURED TO A PALLET WITH 60 POUNDS OF
SECURED WEIGHT IN EACH DRAWER, 75 POUNDS OF
SECURED WEIGH ON EACH SHELF, AND 100 POUNDS
OF SECURED WEIGHT ON THE BOTTOM PAN/FLOOR
OF THE SHELF CABINET WITHOUT ANY PERMENANT
DAMAGE
ROAD TEST
THE DRAWERS SHALL REMAIN FIRMLY INSTALLED
AFTER 400 MILES OVER PAVED ROADS AND 600 MILES
OVER SECONDARY ROADS (0.2</=RMS RANGE, IN </=
0.6)
ENVELOPE
IN THE CONFIGURATION SHOWN, THE ASSEMBLY
SHALL FIT IN AN ENVELOPE NO LARGER THAN 66"
WIDE BY 33" LONG BY 46" HIGH
DWG NO.
U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND
ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299
EDGEWOOD CHEMICAL BIOLOGICAL CENTER
CONTRACT NO.
5B5M3
CAGE CODE
D
SIZE
3 PLACE DECIMALS ±
2 PLACE DECIMALS ± .03
SHEETSCALE
DRAWING APPROVAL
DESIGN APPROVAL
SUBMITTED
CHECKERDRAWN BY
ORIGINAL DATE
MATERIAL
TOLERANCES ON:
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
EQUIPMENT CODE NO.
NEXT ASSY
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
D
C
B
A
D
C
B
A
FRACTIONS ± CABINET I-J ASSEMBLY
11B5140006 1:9
2012-08-07
R. McCLAIN R. McCLAIN
(YR-MO-DA)
ANGLES ±
SEE NOTE 6
DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
VENDOR ITEM CONTROL DRAWING
COMPONENT LIST
QTY
REQD.
UNIT OF
MEASURE PART NUMBER DESCRIPTION ITEM
NO.
2 EA 11B5190765 CABINET HOUSING 1
1 EA 11B5190664 CABINET I-J COUNTER TOP 2
2 EA 11B5091037 DRAWER, 5-3/8 3
3 EA 11B5190647 DRAWER, 4-5/8 4
2 EA 11B5091559 DRAWER, 3-7/8 5
1 EA 11B5190826 DRAWER, 2-1/4 6
1 EA 11B5091010 CABINET SHELF 7
1 EA 11B5091009 CABINET BOTTOM PAN 8
1 EA 11B5190665 CABINET J DOOR ASSEMBLY 9
3 EA 11B5091011 MEDIUM BATTEN BAR 10
1 SET 11B5091023 CABINET CASTERS 11
CHECKER
APPLICATION
EQUIPMENT CODE NO.
NEXT ASSY
CONTRACT NO.
DRAWING APPROVAL
DESIGN APPROVAL
ORIGINAL DATE
SUBMITTED
DRAWN BY
(YR-MO-DA)
DWG NO.SIZE
B
CAGE CODE
5B5M3 11B5140006
ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299
U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND
EDGEWOOD CHEMICAL BIOLOGICAL CENTER
SHEET 2 OF 2
2012-08-07
R. McCLAIN R. McCLAIN
CABINET I-J ASSEMBLY
| Sheet1 |
| Drawing View1 |
| Drawing View2 |
| Drawing View3 |
| Drawing View4 |
Sheet2
File details come from the government source that posted it.