22.50

57.00

27.75

NOTES

1. APPLICABLE STANDARDS/SPECIFICATIONS:

A. ASME Y14.100-2004

B. ASME Y14.5-2009

2. IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF SUPPLY

HEREON IS NOT TO BE CONSTRUED AS A GUARANTEE OF PRESENT

OR CONTINUED AVAILABILITY AS A SOURCE OF SUPPLY FOR THE

ITEM DESCRIBED ON THE DRAWING.

3. VENDOR PART NUMBER(S) ARE FOR REFERENCE ONLY. DRAWING

SPECIFICATIONS AND DIMENSIONAL REQUIREMENTS SUPERCEDE

VENDOR PART NUMBER(S) AND/OR CATALOG CALLOUTS.

4. ITEMS MAY NOT COME PRE-ASSEMBLED.

5. CABINET B BOTTOM CABINET ASSEMBLY AS SHOWN MUST BE DIS-

ASSEMBLED ONLY TO THE EXTENT REQUIRED TO MEET

REQUIREMENTS OF ALTERED ITEM DRAWINGS 11B5042105 -

CABINET HOUSING BOTTOM, MODIFIED AND RE-ASSEMBLED AS

ITEM 11B5040008 - CABINET B ASSEMBLY WITHOUT TOOLS.

6. REPLACEMENT PARTS ARE NOTED IN COMPONENT LIST AND ARE

FOR REFERENCE ONLY.

REVISIONS

LTR NOR NUMBER DATE APPROVED

- NOR 738-0001-001 2014-04-25 PMS

SALIENT FEATURES

MUST BE INDUSTRIAL QUALITY

CONFIGURATION CABINET WITH 13 DRAWERS

DRAWER WEIGHT CAPACITY WHEN INSTALLED IN THE HOUSING, DRAWERS SHALL

HAVE A MINIMUM WEIGH CAPACITY OF 400 POUNDS

DROP TEST

SHALL BE CAPABLE OF SURVIVING A 6" FLAT DROP

WHILE SECURED TO A PALLET WITH 50 POUNDS OF

SECURED WEIGHT IN EACH DRAWER WITHOUT ANY

PERMENANT DAMAGE

RAIL IMPACT TEST

SHALL BE CAPABLE OF SURVIVING AN 8 MILE AN HOUR

RAIL IMPACT FORWARD AND BACKWARDS WHILE

SECURED TO A PALLET WITH 50 POUNDS OF SECURED

WEIGHT IN EACH DRAWER WITHOUT ANY PERMENANT

DAMAGE

ROAD TEST

THE DRAWERS SHALL REMAIN FIRMLY INSTALLED AFTER

400 MILES OVER PAVED ROADS AND 600 MILES OVER

SECONDARY ROADS (0.2</=RMS RANGE, IN </= 0.6)

ENVELOPE

IN THE CONFIGURATION SHOWN, THE ASSEMBLY SHALL

FIT IN AN ENVELOPE NO LARGER THAN 22-1/2" WIDE BY

33" LONG BY 57" HIGH

SUGGESTED SOURCE OF SUPPLY

PART

NUMBER

VENDOR DATA

NAME & ADDRESS CAGE

CODE

VENDOR

PART NO. DESCRIPTION

11B5091047

STANLEY VIDMAR STORAGE TECHNOLOGIES

11 GRAMMES ROAD

ALLENTOWN, PA 18103

800-523-9462 34004 P001591A-04

CABINET WITH SHOCK FEATURE, SHOCK

BAR FEATURE, NO PALLET FEET FEATURE,

AND PTFSV PIERCE TOP FEATURE

COMPONENT LIST

QTY REQD UNIT OF

MEASURE

DRAWING OR PART

NO. NOMENCLATURE OR MATERIAL ITEM NO.

1 EA 11B5091035 CABINET HOUSING BOTTOM 1

5 EA 11B5091014 DRAWER, 2-1/4 2

2 EA 11B5091015 DRAWER, 3 3

4 EA 11B5091012 DRAWER, 3-7/8 4

2 EA 11B5091013 DRAWER, 4-5/8 5

1 SET 11B5042107 CABINET STACK HARDWARE 6

DWG NO.

U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND

ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299

EDGEWOOD CHEMICAL BIOLOGICAL CENTER

CONTRACT NO.

5B5M3

CAGE CODE

D

SIZE

3 PLACE DECIMALS ±

2 PLACE DECIMALS ±

SHEETSCALE

DRAWING APPROVAL

DESIGN APPROVAL

SUBMITTED

CHECKERDRAWN BY

ORIGINAL DATE

MATERIAL

TOLERANCES ON:

DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

EQUIPMENT CODE NO.

NEXT ASSY

8 7 6 5 4 3 2 1

8 7 6 5 4 3 2 1

D

C

B

A

D

C

B

A

FRACTIONS ± CABINET B BOTTOM

CABINET ASSEMBLY

11B5091047 1:12

2011-08-01

R. McCLAIN R. McCLAIN

(YR-MO-DA)

ANGLES ±

SEE NOTE 5

DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.

VENDOR ITEM CONTROL DRAWING