11B5040021revA_-_CABINET_X_ASSEMBLY.pdf
PDF 104 KB Posted
- Attached to
- MWMSS Type I and Type II Cabinet Sets Federal contract opportunity
- Solicitation number
- W9098S19T0094
About this file
11B5040021_Cabinet_X_Assembly
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 19T0094-0001_Released.pdf | ||
| Attachment_0001_-_PRICE_MATRIX_19-T-0094.xlsx | XLSX spreadsheet | |
| 11B5091020_-_CABINET_C_TOP_CABINET_ASSEMBLY.pdf | ||
| 11B5140006_-_CABINET_I-J_ASSEMBLY.pdf | ||
| 11B5190645_-_CABINET_F_ASSEMBLY.pdf | ||
| 11B5091067_-_CABINET_B_TOP_CABINET_ASSEMBLY.pdf | ||
| 11B5190652_-_CABINET_G_ASSEMBLY.pdf | ||
| Attachment_0002_CDRL0001_(Commercial_Manuals_&_Copyright_Release)_v1.pdf | ||
| 11B5190656_-_CABINET_F-G_COUNTER_TOP.pdf | ||
| 11B5040015revB_-_CABINET_E_ASSEMBLY.pdf | ||
| 11B5040012_-_CABINET_D_ASSEMBLY.pdf | ||
| Attachment_0003_CDRL0002_(Product_Warranty_Information)_v1.pdf | ||
| 19T0094_Released.pdf | ||
| 11B5091048_-_CABINET_C_BOTTOM_CABINET_ASSEMBLY.pdf | ||
| 11B5040003_-_CABINET_A_ASSEMBLY.pdf | ||
| 11B5040018revA_-_CABINET_W_ASSEMBLY.pdf | ||
| 11B5091047_-_CABINET_B_BOTTOM_CABINET_ASSEMBLY.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
65.87
SEE NOTE 41
4 3X
30.00
27.75
NOTES
1. APPLICABLE STANDARDS/SPECIFICATIONS:
A. ASME Y14.100-2004
B. ASME Y14.5-2009
2. IDENTIFICATION OF THE SUGGESTED SOURCE(S) OF SUPPLY
HEREON IS NOT TO BE CONSTRUED AS A GUARANTEE OF PRESENT
OR CONTINUED AVAILABILITY AS A SOURCE OF SUPPLY FOR THE
ITEM DESCRIBED ON THE DRAWING.
3. VENDOR PART NUMBER(S) ARE FOR REFERENCE ONLY. DRAWING
SPECIFICATIONS AND DIMENSIONAL REQUIREMENTS SUPERCEDE
VENDOR PART NUMBER(S) AND/OR CATALOG CALLOUTS.
4. DOOR NOT SHOWN FOR CLARITY.
5. SOME ASSEMBLY MAY BE REQUIRED.
6. CABINET X ASSEMBLY AS SHOWN MUST BE DIS-ASSEMBLED ONLY
TO THE EXTENT REQUIRED TO MEET REQUIREMENTS OF ALTERED
ITEM DRAWING 11B5091309 - CABINET X HOUSING, AND
RE-ASSEMBLED AS ITEM 11B5040020 - CABINET X ASSEMBLY
WITHOUT TOOLS.
7. REPLACEMENT PARTS ARE NOTED IN COMPONENT LIST AND ARE
FOR REFERENCE ONLY.
REVISIONS
LTR NOR NUMBER DATE APPROVED
- NOR 738-0001-001 2014-04-25 PMS
A 738-0110-006 2016-11-29 PMS
SUGGESTED SOURCE OF SUPPLY
PART
NUMBER
VENDOR DATA
NAME & ADDRESS CAGE
CODE
VENDOR
PART NO. DESCRIPTION
11B5040021
STANLEY VIDMAR STORAGE TECHNOLOGIES
11 GRAMMES ROAD
ALLENTOWN, PA 18103
800-523-9462
34004 PXKK3071A-01
CABINET WITH SHOCK FEATURE, SHOCK
BAR FEATURE, NO PALLET FEATURE, AND
MOBILE SECURING FEATURE.
PARTS LIST
ITEM
NO. PART NUMBER NOMENCLATURE UNIT OF
MEASURE QTY
1 11B5091041 CABINET HOUSING EA 1
2 11B5091010 CABINET SHELF EA 2
3 11B5091009 CABINET BOTTOM PAN EA 1
4 11B5091011 MEDIUM BATTEN BAR EA 3
5 11B5091023 CABINET CASTERS SET 1
6 11B5091044 CABINET DOOR ASSEMBLY EA 1
SALIENT FEATURES
MUST BE INDUSTRIAL QUALITY
CONFIGURATION CABINET WITH TWO SHELVES, BOTTOM PAN, SINGLE DOOR, AND
CASTERS
SHELF ADJUSTMENT
THE SHELVES SHALL BE CAPABLE OF BEING MOVED UP AND DOWN IN
1-3/4" OR LESS INCREMENTS OVER A MINIMUM OF 75% OF THE
CABINETS STORAGE HEIGHT
SHELF WEIGHT CAPACITY WHEN INSTALLED IN THE HOUSING, SHELVES SHALL HAVE A MINIMUM
WEIGH CAPACITY OF 1000 POUNDS
CASTER WEIGHT CAPACITY WHEN INSTALLED ON THE CABINET, CASTERS SHALL HAVE A MINIMUM
WEIGHT CAPACITY OF 3600 POUNDS
BATTEN ADJUSTMENT
THE BATTENS SHALL BE CAPABLE OF BEING MOVED UP AND DOWN IN
1-3/4" OR LESS INCREMENTS OVER A MINIMUM OF 75% OF THE
CABINETS STORAGE HEIGHT
DROP TEST
SHALL BE CAPABLE OF SURVIVING A 6" FLAT DROP WHILE SECURED
TO A PALLET WITH 75 POUNDS OF SECURED WEIGHT ON INSTALLED
SHELVES AND 90 POUNDS OF SECURED WEIGHT ON THE CABINET
FLOOR/BOTTOM PAN WITHOUT ANY PERMENANT DAMAGE
RAIL IMPACT TEST
SHALL BE CAPABLE OF SURVIVING AN 8 MILE AN HOUR RAIL IMPACT
FORWARD AND BACKWARDS WHILE SECURED TO A PALLET WITH 75
POUNDS OF SECURED WEIGHT ON INSTALLED SHELVES AND 90
POUNDS OF SECURED WEIGHT ON THE CABINET FLOOR/BOTTOM PAN
WITHOUT ANY PERMENANT DAMAGE
ROAD TEST
THE SHELVES AND BATTENS SHALL REMAIN FIRMLY INSTALLED AFTER
400 MILES OVER PAVED ROADS AND 600 MILES OVER SECONDARY
ROADS (0.2</=RMS RANGE, IN </= 0.6)
ENVELOPE IN THE CONFIGURATION SHOWN, THE ASSEMBLY SHALL FIT IN AN
ENVELOPE NO LARGER THAN 32-1/2" WIDE BY 33" LONG BY 66" HIGH
DWG NO.
U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND
ROCK ISLAND ARSENAL, ROCK ISLAND, IL 61299
EDGEWOOD CHEMICAL BIOLOGICAL CENTER
CONTRACT NO.
5B5M3
CAGE CODE
D
SIZE
3 PLACE DECIMALS ±
2 PLACE DECIMALS ± .03
SHEETSCALE
DRAWING APPROVAL
DESIGN APPROVAL
SUBMITTED
CHECKERDRAWN BY
ORIGINAL DATE
MATERIAL
TOLERANCES ON:
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
EQUIPMENT CODE NO.
NEXT ASSY
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
D
C
B
A
D
C
B
A
FRACTIONS ± CABINET X ASSEMBLY
11B5040021 1:12
2012-08-03
R. McCLAIN R. McCLAIN
R. McCLAIN
T. LETTIS
P. SCHLUE738
(YR-MO-DA)
ANGLES ±
SEE NOTE 6
DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
VENDOR ITEM CONTROL DRAWING
REV: A
| Sheet1 |
| Drawing View1 |
| Drawing View2 |
| Drawing View3 |
| Drawing View4 |
File details come from the government source that posted it.