W52P1J-22-R-5002 -- Solicitation Attachment 0003 -- Appendix B Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- W52P1J-22-R-5002
About this file
This document package includes drawings and specifications for the construction of a splash pad in Memorial Park on Rock Island Arsenal in Illinois. The project involves installing a new splash pad surface, underground plumbing and utilities, site lighting, and associated site work. Key details include specifications for items like backflow preventers, underground piping, and concrete mixes. Drawings provide information on the existing site conditions, proposed site plans, and plumbing and electrical layouts. The solicitation also includes general notes outlining requirements for the project and responsibilities of the contractor. The United States Army Contracting Command - Rock Island is requesting proposals due by February 14th, 2022 for the construction of this splash pad facility.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROCK ISLAND ARSENAL
G-001
C O
V E
R
S
H E
E T
PROJECT: BUILD SPLASH PAD AT
MEMORIAL PARK
APPENDIX B: DRAWINGS
PR NO: 2022-102
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
U S
A
R M
Y
G
A R
R I S
O N
R O
C K
I S
L A
D
A
S
E N
A L
D I R
E C
T O
R A
T E
F
P
U B
L
W
R
K S
R O
L A
N D
I L
M E
M O
R I A
L
P
A R
K
B U
I L
D
S
P L
A S
H
P
A D
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
D E
S I G
N E
D
B
Y
J O
L
D R
A W
N
B
Y
J O
L
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
B
Y
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
C
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I N
G
D
RG
-8
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text M
AutoCAD SHX Text Y
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text K
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text B
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text K
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
GENERAL (APPENDIX B)
TITLE OF DRAWING
SHEET
ID.
ELECTRICAL (APPENDIX B)
G-001 COVER SHEET
A B
B R
E V
I A
T I O
N S
S
Y M
B O
L S
A
N D
G E
N E
R A
L
N
O T
E S
NOT TO SCALE (NTS)
G-002
G-002 PROJECT LOCATION, DRAWING INDEX, ABBREVIATIONS, SYMBOLS, AND GENERAL SHEET NOTES
E-102 ELECTRICAL PLAN
E-101 ELECTRICAL PLAN
D7
INDEX OF DRAWINGS
ROCK ISLAND
ARSENAL
ILLINOIS
IOWA
INDIANA
KENTUCKY
MISSOURI
WISCONSIN
CHICAGO
ST. LOUIS
A7
VICINITY & AERIAL MAPS
OF ROCK ISLAND ARSENAL
PROJECT LOCATION
CIVIL (APPENDIX B)
C-102 QUANTITIES AND TYPICALS
C-101 QUANTITIES AND TYPICALS
GENERAL NOTES
DETAIL
NUMBER (TYP.)
AREA COVERED BY DETAIL
KEYNOTE
TAG
SCALE
DETAIL IDENTIFIER (MODULE LETTER AND NUMBER)
A1
NORTH ARROW
PLAN, ELEVATION, SECTION, OR DETAIL NAME
PLAN, ELEVATION, SECTION, OR DETAIL VIEW TITLE
SYMBOLS:
VIEW TITLES:
ARCHITECTURAL ABBREVIATIONS
A-000
A-000
SECTION NUMBER
DWG. NO. WHERE
SECTION IS DRAWN
SECTION MARK
A-000
ELEVATION NUMBER
DWG. NO. WHERE
ELEVATION IS DRAWN
BUILDING ELEVATION MARK
DWG. NO. WHERE
DETAIL IS DRAWN
CALLOUT HEAD
ABOVE FINISHED FLOOR
ACCESS DOOR / PANEL
AMERICAN WITH DISABILITIES
ACCESSIBILITY GUIDELINES
ACCESSORIES
ADJUST/ ADJUSTABLE
ANCHOR BOLT
ANODIZED
ALUMINUM
AND
ANGLE
APPROVED
APPROXIMATE
ARCHITECTURAL
AT
ANTI TERRORISM / FORCE PROTECTION
AVERAGE
BEAM
BLOCKING
BOARD
BOTTOM
CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CHANNEL
CENTER
CENTER LINE
CENTER TO CENTER
CLEAR
CLEANOUT
COMPANY
COLUMN
CONCRETE
CONTRACTING OFFICER'S
REPRESENTATIVE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CONTROL JOINT
CUBIC YARD
DETAIL
DIAMETER
DIMENSION
DRAWING
EACH
ELECTRICAL OR ELECTRIC
ELEVATION
EPOXY PAINT
ENGINEER
EQUIPMENT
EQUAL
EXISTING
EXTERIOR
FACTORY
FEET
AFF
ACC DR
ADAAG
ACCESS
ADJ
AB
ANOD
AL / ALUM
L
APP
APPROX
ARCH
ATFP
AVG
BM
BLKG
BD
BTM
CFCI
CH
CTR
C TO C
CT
CLR
CO
COL
CONC
COR
CONST
CONT
CONTR
CJ
CY
DET
DIA
DIM
DWG
EA
ELEC
EL
EP
ENGR
EQUIP
EQ
EXIST
EXT
FAC
FT
FINISH
FLAT PAINT
FLOOR DRAIN
FOOTING
FOUNDATION
FIELD VERIFY
GAGE OR GAUGE
GALVANIZED
GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GLOSSY PAINT
GOVERNMENT
HEIGHT
HIGH
HIGH POINT
HOLLOW METAL
HORIZONTAL
HOSE BIBB
INTERNATIONAL BUILDING
CODE
INCH
INSIDE DIAMETER
INSULATION
INTERIOR
JOINT
LIGHT
LIGHTING
LONGITUDINAL
LOUVER
LOW POINT
MANAGER
MANUFACTURER
MATERIAL
MAXIMUM
MECHANICAL
METAL
METAL WALL PANEL
MINIMUM
MISCELLANEOUS
NOT IN CONTRACT
NUMBER
NOT TO SCALE
NATIONAL FIRE PROTECTION
ASSOCIATION
ON CENTER
OWNER FURNISHED
CONTRACTOR INSTALLED
OWNER FURNISHED
GOVERNMENT INSTALLED
OPENING
OPPOSITE
OUTSIDE DIAMETER
OCCUPATIONAL SAFETY AND
HEALTH ACT
FIN
FLR
FD
FTG
FDN
FV
GA
GALV
GFCI
GFGI
GP
GOVT
HT
H
HP
HM
HORIZ
HB
IBC
IN
ID
INSUL
INT
JT
LT
LTG
LONG
LVR
LP
R
MANUF
MATL
MAX
MECH
MTL
MWP
MIN
MISC
NIC
NO (#)
NTS
NFPA
OC
OFCI
OFGI
OPNG
OPP
OD
OSHA
OVERHEAD
PAINT
PAIR
PANEL
PLASTIC
PLATE
PLYWOOD
POUNDS
POUNDS / SQUARE FOOT
POUNDS / SQUARE INCH
PRE-MOLDED JOINT FILLER
PREFABRICATED
REINFORCEMENT
REQUIRED
REVISIONS / REVISED
ROUGH OPENING
SEALED CONCRETE
SCHEDULE
SECTION
SEMI-GLOSS PAINT
SHEET METAL
SIMILAR
SPECIFICATION
SQUARE
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
THICK
TOP OF
TOP OF BEAM
TOP OF CONCRETE
TOP OF CURB
TOP OF STEEL
TYPICAL
UNIFIED FACILITIES CRITERIA
UNDERWRITERS LABORATORIES
UNFINISHED
UNLESS NOTED OTHERWISE
VERTICAL
WIDTH
WITH
WALL CLEAN OUT
WITHOUT
WEATHERSTRIPPING
YARD
OVHD
PT
PR
PNL
PLAS
PL
PLYWD
LBS OR #
PSF
PSI
PMJF
PRE-FAB
REINF
REQ'D
REV
RO
SC
SCHED
SECT
SGP
SHT MET
SIM
SPEC(S)
SQ
SS
STD
STL
STOR
STRUCT
SUSP
THK
T/
TOB
TOC
T/C
TOS
TYP
UFC
UL
UNFIN
UNO
VERT
W
W/
WCO
W/O
WS
YD
1. NOTES FOUND ON G-SHEETS, ARE GENERAL NOTES AND APPLY TO THE ENTIRE PROJECT TO INCLUDE
THE COMPLETE PLAN SET AND SPECIFICATIONS, UNLESS NOTED OTHERWISE. SHEET NOTES APPLY TO
ALL PLANS, ELEVATIONS, SECTIONS, AND DETAILS FOR THAT SHEET, UNLESS NOTED OTHERWISE.
KEYNOTES APPLY TO ELEMENTS ON THE SHEET AS INDICATED, UNLESS NOTED OTHERWISE.
2. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT INTENDED TO
INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT DOCUMENTS.
3. WORK ITEMS ENUMERATED IN ONE PORTION OF THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED
TO EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED THEREFROM ELSEWHERE IN THE DOCUMENTS.
4. COORDINATE THE WORK SO THAT NO WORK IS LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
5. THE CONTRACTOR SHALL PROTECT EXISTING AND NEW WORK. NFPA 241, STANDARD FOR
SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS SHALL BE APPLIED.
6. ITEMS NOTED "N.I.C." ARE EXCLUDED FROM THE CONSTRUCTION SCOPE OF WORK, UNLESS
MODIFICATIONS REQUIRED TO PERFORM OTHER WORK REQUIRES MODIFICATIONS OF THOSE NOTED
ITEMS.
7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF
MATERIALS AND RUBBISH CREATED DURING THE PROJECT TO A SITE OFF THE RIA INSTALLATION. EMPTY
DUMPSTERS AND LEGALLY DISPOSE WASTE OFF SITE DAILY. DUMPSTERS SHALL BE LOCATED ON SITE IN
ACCORDANCE WITH THE SETBACK DISTANCES REQUIRED BY THE UFC 4-010-01 DOD MINIMUM
ANTITERRORISM STANDARDS FOR BUILDINGS AND SHALL BE INSPECTED BY FORCE PROTECTION PRIOR
TO BEING MOVED CLOSER TO, OR INSIDE OF THE BUILDING.
8. DIMENSIONS AND PLANS ARE NOT WARRANTED AS ACCURATE. PRIOR TO BID, THE CONTRACTOR SHALL
FIELD VERIFY DIMENSIONS AND EXISTING CONDITIONS THAT MAY AFFECT THE WORK .
9. DO NOT SCALE DRAWINGS; LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS.
10. PRODUCTS LISTED IN THE DRAWINGS REPRESENT A DESIGN BASIS. THE CONTRACTOR CAN SUBSTITUTE
PRODUCTS THAT ARE EQUAL OR BETTER THAN THE DESIGN BASIS IF SUBMITTED TO THE C.O.R. AND
APPROVED BY THE GOVERNMENT.
11. DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.
12. THE CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND
PROPERTY, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND
PROPERTY AS NECESSARY.
13. PRODUCTS LISTED ON DRAWINGS AND NOT INDICATED IN SPECIFICATIONS SHALL BE SUBMITTED FOR
GOVERNMENT APPROVAL. CONTRACTOR SHALL ADD THESE TO THEIR SUBMITTAL REGISTER. PRODUCTS
LISTED ON DRAWINGS TAKE PRECEDENCE OVER SPECIFICATIONS.
14. DEMOLITION OR NEW WORK MAY NOT BE INDICATED ON THEIR CORRESPONDING SHEETS, BUT MAY BE
REQUIRED FOR WORK TO BE PERFORMED.
15. THE CONTRACTOR SHALL COORDINATE PARKING, JOB TRAILER, STAGING, DUMPSTER LOCATIONS AND
OTHER NECESSARY SPACES WITH C.O.R.
16. PROTECT OR RELOCATE ADJACENT ITEMS, EQUIPMENT, AND STRUCTURES AS NECESSARY TO
FACILITATE THE EXECUTION OF THE WORK. MAINTAIN THE EXISTING PERFORMANCE CAPABILITIES OF
THE RESPECTIVE PROTECTED AND MOVED ITEMS, EQUIPMENT AND STRUCTURES.
17. IN ORDER TO MORE CLEARLY DEPICT WORK BEING IDENTIFIED ON A DRAWING, CONTRACTED WORK
ITEMS ARE GENERALLY SHOWN IN HEAVY (BOLD) LINE WEIGHT AND BLACK LINE WORK. GRAY SCALE
LINE WORK, GENERALLY DENOTES EXISTING CONDITIONS. NOTE: THERE ARE EXCEPTIONS TO THESE
RULES AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO THOROUGHLY REVIEW DRAWINGS AND
REQUEST ADDITIONAL INFORMATION PRIOR TO BIDDING. NOTE THAT WORK SHOWN ON ONE DRAWING
MAY INDICATE OR IMPLY WORK TO BE PERFORMED ON OTHER DRAWINGS THAT IS NOT CURRENTLY
INDICATED.
18. NORMAL INSTALLATION WORKING HOURS WILL BE BETWEEN 0700-1700, MONDAY THROUGH FRIDAY.
HOURS OUTSIDE THE NORMAL RANGE REQUIRES COORDINATION AND APPROVAL FROM THE
CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.) TWO WEEKS PRIOR. THE FACILITY WILL BE
CLOSED ON GOVERNMENT HOLIDAYS. CONTACT THE C.O.R. FOR A LIST OF GOVERNMENT HOLIDAYS.
19. THE CONTRACTOR SHALL MAKE REQUESTS TO DISCONNECT POWER OR UTILITIES PER
SPECIFICATIONS. WORK REQUIRING POWER REMOVAL SHALL BE DONE IN A TIMELY MANNER AND
OUTSIDE NORMAL INSTALLATION WORKING HOURS WHEN POSSIBLE. WHEN SAFE CONDITIONS ARE
RE-ESTABLISHED FOR BOTH THE CONTRACTOR AND THE PUBLIC, THE CONTRACTOR SHALL
IMMEDIATELY RESTORE THE POWER.
20. THE CONTRACTOR SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM THE INSTALLATION
AUTHORITIES HAVING JURISDICTION.
21. THE CONTRACTOR SHALL COMPLY WITH THE ROCK ISLAND ARSENAL POLICIES AND PROCEDURES.
22. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH APPLICABLE CODES, ORDINANCES, AND REGULATORY AGENCIES. ANY CONFLICTS WITH THE CODE AND THE CONTRACT DOCUMENTS
ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE C.O.R.
23. WORK SHALL BE DONE USING THE DEGREE OF SKILL, EFFICIENCY AND KNOWLEDGE THAT IS
COMMONLY USED BY THOSE EMPLOYED TO PERFORM THAT PARTICULAR TYPE OF WORK. CONFORM
TO APPLICABLE INDUSTRY OR MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF
MATERIALS AND WORKMANSHIP, AS WELL AS, THE REQUIREMENTS IN THESE DRAWINGS AND
SPECIFICATIONS. CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT
TO THE ATTENTION OF THE C.O.R. PRIOR TO PROCEEDING WITH THE WORK.
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
I L
FOR ADVERTISEMENT
M E
M O
R I A
L
P
A R
K
B U
I
P L A
H
D
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
D E
S I G
N E
D
B
Y
J O
L
D R
A W
N
B
Y
J O
L
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
C
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I N
G
D
RG
-8
C-103 GENERAL NOTES
C-104 EXISTING SITE PLAN (NORTH)
C-105 PROPOSED SITE PLAN
C-106 PROPOSED SITE PLAN (NORTH)
C-107 PROPOSED SITE PLAN (NORTH)
C-108 PROPOSED SITE PLAN (SOUTH)
SPLASH PAD DRAWINGS (APPENDIX C)
A-001 SPLASH PAD - SITE PLAN AND GENERAL NOTES
A-002 SPLASH PAD - ANCHOR PLAN
C-001 SPLASH PAD - ANCHOR DETAILS
C-002 SPLASH PAD - ANCHOR DETAILS
FT-001 SPLASH PAD - FIXTURE DETAILS
PE-001 SPLASH PAD - PLUMBING AND ELECTRICAL LAYOUT
E-001 SPLASH PAD - BONDING LAYOUT
ED-001 SPLASH PAD - ELECTRICAL DETAILS
AutoCAD SHX Text
NORTH
NORTH
C-101
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
I L
R G
D
D E
S I G
N E
D
B
Y
M S
U L L I V
A N
D R
A W
N
B
Y
M
S
U L L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
G
STATUS
U
I
L A
M E
M O
R I A
L
P
A R
K
Q U
A N
T I T
I E
S
A
N D
T Y
P I C
A L
S
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4
6 7 8 9 10
SYMBOLS
EX. ELECTRICAL BOX
EX. TREE
EX. UTILITY POLE/SIREN
EX. TELEPHONE PED
FEN EX. FENCE LINE
OHE EX. OVERHEAD ELECTRIC
UE EX. UNDERGROUND ELECTRIC
NOTE
1.) THE CONTRACTOR SHALL FOLLOW THE IOWA STATE WIDE URBAN DESIGN AND SPECIFICATIONS (SUDAS) FOR THE CIVIL PORTION OF THE
PROJECT. THE SPECIFICATIONS CAN BE FOUND AT https://iowasudas.org/manuals/specifications-manual/
2.) MATERIAL SUBMITTALS ARE REQUIRED FOR ALL MATERIAL USED FOR THE PROJECT. MATERIAL SPECIFICATIONS CAN BE FOUND IN THE
SUDAS SPECIFICATIONS.
3.) THE FOLLOWING QUANTITIES ARE FOR CONCEPTUAL PURPOSES AND MAY BE ALTERED BY THE MANUFACTURES SPECIFICATIONS OF THE SPLASH PAD. REGARDLESS OF THE MANUFACTURES SPECIFICATIONS A 5' WIDE SIDEWALK IS REQUIRED AROUND THE PERIMETER OF THE
SPLASH PAD.
4.) THE CLASS 13 EXCAVATION INCLUDES A 30% SHRINK ADDED TO THE QUANTITY.
5.) BID ITEMS 13-17 HAVE SUPPLEMENTAL SPECIFICATIONS DEFINED ON SHEET C-102.
PROPOSED TOPSOIL AREA
T
E
EX. GUY WIRE
2'' HDPE << EX. SANITARY SEWER 2" HDPE
2'' W EX. 2" WATER LINE
EX. WATER UTILITY MH
EX. BOLLARD
TYPICAL BERM CROSS SECTION
SCALE: 1" = 2'
EX. GROUND PROFILE
PROP. BERM
TOP OF BERM
TARGET ELEV. = 573.32'
TOP OF BERM
TARGET ELEV. = 573.32'
TOE OF BERM
TARGET ELEV. = 572.10'4:1 SLO
PE 3:1 SLOPE
NOTE:
1.)THE INVERT TO 18" CLAY PIPE THAT
LEADS TO THE RIVER IS 571.62'.
PLACE EROSION STONE & ENGINEERING FABRIC
ALONG THE INSIDE AND BOTTOM OF
THE PROPOSED BERM AT A 6" DEPTH
2'
4' (3.9')
(4.5')
PROP. WATER BACKFILL PREVENTER
PROP. WATER VALVE
WV
C-102
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
I L
R G
D
D E
S I G
N E
D
B
Y
M S
U L L I V
A N
D R
A W
N
B
Y
M
S
U L L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I
L A
M E
M O
R I A
L
P
A R
K
Q U
A N
T I T
I E
S
A
N D
T Y
P I C
A L
S
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4
6 7 8 9 10
SUPPLEMENTAL PLUMBING SPECIFICATIONS
ITEM DESCRIPTION
BASIS OF DESIGN
MANUFACTURER
BACKFLOW
PREVENTER
BACKFLOW PREVENTION DEVICES MUST BE
APPROVED BY THE STATE OR LOCAL
REGULATORY AGENCIES. IF THERE IS NO STATE
OR LOCAL REGULATORY AGENCY
REQUIREMENTS, THE BACKFLOW PREVENTION
DEVICES MUST BE LISTED BY THE FOUNDATION
FOR CROSS-CONNECTION CONTROL & HYDRAULIC
RESEARCH, OR ANY OTHER APPROVED TESTING
LABORATORY HAVING EQUIVALENT CAPABILITIES
FOR BOTH LABORATORY AND FIELD EVALUATION
OF BACKFLOW PREVENTION DEVICES AND
ASSEMBLIES. REDUCED PRESSURE PRINCIPLE
BACKFLOW PREVENTERS SHALL CONFORM TO
ASSE 1013. AIR GAPS IN PLUMBING SYSTEMS
SHALL CONFORM TO ASME A112.1.2. PROVIDE
QUARTER-TURN BALL VALVES, BRONZE INLET
STRAINER. INSTALL UNIONS ON BOTH SIDES OF
BACKFLOW PREVENTER TO ALLOW FOR
REMOVAL. SIZE SHALL BE 2" WITH A MAXIMUM
PRESSURE DROP OF 15 PSI AT 80 GPM.
WATTS SERIES 009
VALVE BOX
THE ENCLOSURE SHALL BE OF LIFELIKE
POLYETHYLENE CONSTRUCTION WITH NOT
INSULATION, PROVIDING ACCESS THROUGH
DOORS FOR TESTING/CERTIFICATION PURPOSES.
IT MUST ALSO BE REMOVABLE FOR MAINTENANCE
PURPOSES. NO WOOD OR “PARTICLE BOARD”
SHALL BE ALLOWED IN ASSEMBLY. THE
ENCLOSURES ARE PROVIDED WITH MEANS OF
PERMANENT ANCHOR. ALL “WET” PORTIONS OF
THE BACKFLOW PREVENTION ASSEMBLY SHALL
BE PROTECTED WITHIN THE ENCLOSURE.
PROVIDE CONCRETE PAD IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
WATTS MODEL
WATTSROCK WPLRN-2
UNDERGROUND
WATER PIPING
SEAMLESS COPPER WATER TUBE, ASTM B88.
TYPE K SOFT COPPER. BRAZED JOINTS SHALL BE
MADE IN CONFORMANCE WITH AWS B2.2/B2.2M,
ASME B16.50, AND CDA A4015 WITH FLUX AND ARE
ACCEPTABLE FOR ALL PIPE SIZES. COPPER TO
COPPER JOINTS SHALL INCLUDE THE USE OF
COPPER-PHOSPHORUS OR
COPPER-PHOSPHORUS-SILVER BRAZING METAL
WITHOUT FLUX. BRAZING OF DISSIMILAR METALS
(COPPER TO BRONZE OR BRASS) SHALL INCLUDE
THE USE OF FLUX WITH EITHER A
COPPER-PHOSPHORUS,
COPPER-PHOSPHORUS-SILVER OR A SILVER
BRAZING FILLER METAL. SOLDERED JOINTS SHALL
BE MADE WITH FLUX AND ARE ONLY ACCEPTABLE
FOR PIPING 2 INCHES AND SMALLER. SOLDERED
JOINTS SHALL CONFORM TO ASME B31.5.
C-103
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
I L
R G
D
D E
S I G
N E
D
B
Y
M S
U L L I V
A N
D R
A W
N
B
Y
M
S
U L L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I
L A
M E
M O
R I A
L
P
A R
K
G E
N E
R A
L
N
O T
E S
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4
6 7 8 9 10
1.) THIS PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE 2021 EDITION OF THE STATEWIDE
URBAN DESIGN AND SPECIFICATIONS PROGRAM (SUDAS) UNLESS OTHERWISE NOTED. THE
SPECIFICATIONS CAN BE FOUND AT THE FOLLOWING WEBSITE https://iowasudas.org/
2.) IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT ALL EXISTING UTILITIES AND
PAVED STREETS, INCLUDING ANY NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL
VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER AND
DEPARTMENT OF PUBLIC WORKS IF ANY CONFLICTS WITH THE DRAWINGS OCCUR. ANY DAMAGE TO
EXISTING UTILITIES CAUSED BY TRENCHING AND GRADING OPERATIONS SHALL BE REPAIRED AT THE
CONTRACTOR'S EXPENSE. EXISTING UTILITY LOCATIONS SHOWN ON THE DRAWINGS ARE
APPROXIMATE. IT IS POSSIBLE THAT THERE ARE OTHER UTILITIES WHOSE EXISTENCE IS PRESENTLY
NOT KNOWN OR SHOWN. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE TYPE
AND LOCATION OF UNDERGROUND UTILITIES AND TO AVOID DAMAGE THERETO. MINOR CONFLICT
WITH UNDERGROUND UTILITIES THAT ARE ABANDONED BUT NOT REMOVED BY THE OWNER OF THE
UTILITY SHALL BE REMOVED AS NECESSARY FOR THE CONSTRUCTION OF THE PROJECT BY THE
CONTRACTOR. REMOVAL SHALL BE INCIDENTAL TO THE JOB AND SHALL NOT ENTITLE THE
CONTRACTOR TO ANY EXTRA COMPENSATION.
3.) THE DEPARTMENT OF PUBLIC WORKS SHALL HAVE ACCESS TO THE PROJECT FOR CONSTRUCTION
AND TO MAKE EXTENSIONS OR ADJUSTMENTS OF SERVICES.
4.) ALL UNSUITABLE MATERIAL, CONSTRUCTION DEBRIS RESULTING FROM CONSTRUCTION OPERATIONS
SHALL BE PROPERLY DISPOSED OF OFF-SITE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
GUIDELINES.
5.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE WASTE AREAS OR DISPOSAL SITES
FOR EXCESS OR UNDESIRABLE MATERIAL. WHICH IS NOT TO BE INCORPORATED IN THE WORK
INVOLVED IN THIS PROJECT. NO PAYMENT FOR OVERHAUL WILL BE ALLOWED FOR MATERIAL HAULED
TO THESE SITES.
6.) THE CONTRACTOR SHALL PREVENT SILT AND DEBRIS FROM ENTERING STORM SEWERS AND
CULVERTS AND SHALL REMOVED ANY SUCH MATERIAL THAT ENTERS THEM.
7.) CARE SHALL BE TAKEN TO PREVENT STORM WATER FROM UNDERMINING THE PAVEMENT DURING
CONSTRUCTION. IF AREAS BECOME UNDERMINED, THEY SHALL BE REPAIRED IN A MANNER
ACCEPTABLE TO THE ENGINEER/C.O.R. REPRESENTATIVE. PRESSURE GROUTING MAY BE REQUIRED.
8.) THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ADJACENT STREETS FREE FROM
EXCESSIVE BUILD-UP OF SOIL AND/OR GRANULAR MATERIAL FROM THE PROJECT. THE CONTRACTOR
SHALL CLEAN EXCESS SOIL AND OTHER MATERIAL FROM THE ADJACENT STREETS AS REQUIRED BY
THE ENGINEER/C.O.R. REPRESENTATIVE. ANY DAMAGE DONE TO EXISTING STREETS SHALL BE
REPAIRED AT THE CONTRACTOR'S EXPENSE.
9.) THE CONTRACTOR SHALL TAKE MEASURES TO PREVENT THE SPREAD OF DUST FROM THE
CONSTRUCTION AREAS AND HAUL ROUTES, WHICH INCLUDE THE APPLICATION OF WATER AS
DIRECTED BY THE ENGINEER/C.O.R. REPRESENTATIVE. THIS WORK SHALL BE CONSIDERED
INCIDENTAL TO EARTH EXCAVATION.
10.) WHEN NOT INITIATED AT AN EXISTING JOINT, REMOVAL OF EXISTING CONCRETE PAVEMENT, ASPHALT
OR CONCRETE DRIVES AND SIDEWALKS SHALL BE INITIATED WITH FULL DEPTH SAW CUTS,
EXERCISING EXTREME CARE TO AVOID SURFACE BREAKS AND SPALLING. IF SURFACE BREAKS OR
SPALLING OCCUR, ADDITIONAL REMOVAL AND REPLACEMENT SHALL BE MADE AT THE CONTRACTOR'S
EXPENSE. THE COST OF SAW CUTS SHALL BE CONSIDERED INCIDENTAL TO THE COST OF
CONSTRUCTION.
11.) SPECIAL CARE SHALL BE TAKEN FORMING AT INTERSECTIONS SO THAT THE PROFILES
AND GRADES OBTAINED ARE AS SHOWN ON THE PLANS AND GRADE SHEETS. SHORT
LENGTHS OF FORMS OR FLEXIBLE FORMS MAY BE NECESSARY AT THESE LOCATIONS.
12.) ALL CONCRETE SHALL UTILIZE A SUDAS MIX DESIGN AND HAVE A COMPRESSIVE
STRENGTH OF 3,500 PSI AT 14 DAYS AND 4,000 PSI AT 28 DAYS.
13.) THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY IF ANY DISCREPANCIES
ARE ENCOUNTERED BETWEEN THE PLANS AND SPECIFICATIONS AND THE EXISTING
FIELD CONDITIONS. WORK WARRANTING A CHANGE IN SCOPE SHALL BE SUBMITTED TO
THE C.O.R. WITHIN 30 DAYS OF NOTICE OR THE CONTRACTOR WILL FORFEIT RIGHTS TO
COMPENSATION FOR THE WORK.
14.) PUMPING GROUND WATER AND/OR STORM WATER FROM OPEN TRENCHES SHALL BE
CONSIDERED INCIDENTAL TO THE CONTRACT.
15.) CONSTRUCTION STAKING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE
CONTRACTOR AND SURVEY CREW AND COMPANY SHALL BE CONSIDERED COMPETENT
AND RESPONSIBLE FOR REPORTING ANY DISCREPANCIES OR UNFORESEEN PROJECT
ERRORS BEFORE AND DURING CONSTRUCTION STAKING TO ENSURE BLUNDERS AND
MISINFORMATION IS NOT CONSTRUCTED IN THE FIELD. IF AN APPARENT ERROR IN THE
DESIGN IS DISCOVERED DURING CONSTRUCTION STAKING OF THE PROJECT, THE
CONTRACTOR AND OR SURVEY CREW AND COMPANY SHALL CEASE CONSTRUCTION
AND REPORT IT TO DPW IMMEDIATELY SO THE ERROR MAY BE CORRECTED AS SOON AS
POSSIBLE. ANY LOST WORK TIME, LABOR OR EQUIPMENT FEE WILL NOT BE PAID DURING
WORK STOPPAGE DUE TO UNFORESEEN ERROR.
17.) ALL EXISTING STORM INFORMATION SHALL BE CONSIDERED A REFERENCE AND IS THE
RESPONSIBILITY OF THE CONTRACTOR VERIFY IN THE FIELD PRIOR TO CONSTRUCTION.
18.) THE CONTRACTING AUTHORITY RESERVES THE RIGHT TO KEEP ANY/ALL REMOVED
MATERIAL THAT INCLUDES BUT IS NOT LIMITED TO MANHOLES AND STORM SEWER PIPE.
IF THE CONTRACTING AUTHORITY ELECTS NOT TO KEEP REMOVED MATERIAL, THE
MATERIAL BECOMES THE PROPERTY OF THE CONTRACTOR AND IS RESPONSIBLE FOR
THE DISPOSAL/REMOVAL FROM THE PROJECT.
19.) SURVEY DATUM: NAD83 ILLINOIS STATE PLANE, WEST (IL83-WF).
GENERAL NOTES
C-104
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
I L
R G
D E
S I G
N E
D
B
Y
M S
U L L I V
A N
D R
A W
N
B
Y
M
S
U L
L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I L
L
A S
H
P
M E
M O
R I A
L
P
A R
K
E X
S
I T
E
P
L A
N
N
O R
T H
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
EX. PLAYGROUND
EX. PLAYGROUND
EX. CONC.
PAD
EX. CONC.
PAD
EX. CONC.
PAD
EX
. C
ON
C.
PA
D
EX
. H
M A
PA
RK
IN
G
LO
T
EX. EDGE HMA
EX
. C O
NC
PA
D
EX. PLAYGROUND
EX. SAND VOLLEYBALL COURT
REMOVE EX. SAND VOLLEYBALL COURT,
GRADE AND PLACE TOPSOIL,
HYDRO-SEED AND MULCH
AREA OF COURT = 1,028.58 SY
CL 13 EXCAVATION = 33.82 CY (FILL)
REMOVE EX. PLAYGROUND,
GRADE AND PLACE TOPSOIL,
HYDRO-SEED AND MULCH
AREA OF PLAYGROUND = 112.32 SY
CL 13 EXCAVATION = 32.29 CY (CUT)
EX
. C O
NC
PA
D
REMOVE EX. CONC. PAD
GRADE, TOPSOIL,
HYDRO-SEED AND MULCH
AREA CONC PAD = 33.55 SY
REMOVE EX. MULCH
TRAIL, GRADE,
TOPSOIL, HYDRO-SEED
AND MULCH
32.64 SY
Feet
0 20 40
NOTES:
1.) SEE ELECTRICAL SHEETS FOR ELECTRICAL REMOVALS.
2.) A LAYOUT OF THE PROPOSED SPLASH PAD HAS BEEN ADDED TO THIS
SHEET ALONG WITH EXISTING GRADE ELEVATIONS FOR GRADING
PURPOSES.
3.) EG = EXISTING GRADE ELEVATIONS.
MATCH LINE MATCH LINE
SIDEWALK & SPLASH PAD
LAYOUT
N
S
W E
O
HE
O
HE
O
HE
O
HE
O
HE
O
HE
O
HE
O
HE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
U E
OHE
OHE
2'' W 2'' W
2'' W 2'' W
2'' W 2'' W
2'' W 2'' W
UE
UE
UE
UE
U E
FE
N
F
EN
F
EN
F
EN
E
E
E
E
T
584.57' EG
584.57' EG
584.57' EG
584.57' EG
584.57' EG
584.57' EG
584.57' EG
584.57' EG
584.57' EG 584.57' EG
583.53' EG
583.57' EG
584.27' EG
584.43' EG
584.25' EG
584.03' EG
W E
Feet
0 25 50
C-105
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
R G
D E
S I G
N E
D
B
Y
M S
U L
L I V
A N
D R
A W
N
B
Y
M
S
U L
L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I L
L
A S
H
P
M E
M O
R I A
L
P
A R
K
P R
O P
S
I T
E
P
L A
N
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
EX. CONC.
PAD
EX. HMA PARKING LOT
NOTES:
1.) SEE ELECTRICAL SHEETS FOR ELECTRICAL REMOVALS.
EX. CONC.
PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.
PAD
EX
. C
ON
C.
PA
D
EX
. C O
NC
PA
D
LOCATION OF THE EX. SPETIC
TANK HAS NOT BEEN VERIFIED
APPROX LOCATION BASED ON
HISTORICAL MAPS.
EX. CONC. DUMPSTER PAD
EX
. C O
NC
PA
D
REMOVE EX. CONC. PAD
GRADE, TOPSOIL,
HYDRO-SEED AND MULCH
33.55 SY
UE
UE
UE
UE
2'' W 2'' W
2'' W
2'' HDPE << 2'' HDPE << 2'' HDPE << 2'' HDPE <<
2''
HD
PE
BUILDING
(EX. RESTROOMS)
ABANDON SEPTIC
TANK
E
18'' VC >>
W E
Feet
0 25 50
C-106
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
R G
D E
S I G
N E
D
B
Y
M S
U L
L I V
A N
D R
A W
N
B
Y
M
S
U L
L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I L
L
A S
H
P
M E
M O
R I A
L
P
A R
K
P R
O P
S
I T
E
P
L A
N
N
O R
T H
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
EX
. H
M A
PA
RK
IN
G
LO
T
EX
. C O
NC
PA
D
MATCH LINE
EX. PLAYGROUND
CONC.
PAD
CONC.
PAD
CONC.
PAD
EX. PLAYGROUND
℄ RODMAN AVENUE
EDGE OF EX. SIDEWALK
EDGE OF EX. HMA ROAD
EDGE OF EX. HMA ROADINSTALL VALVE BOX
INSTALL BACKFLOW PREVENTERINSTALL VALVE-CURB BOX
INSTALL 2" TYPE K COPPER WATER SERVICE LINE
LINE TO BE INSTALLED TRENCHLESS
201 LF
NOTES:
1.) TRESS SHALL NOT BE DISTURBED.
2.) SEE ELECTRICAL SHEETS FOR ELECTRICAL REMOVALS
MATCH LINE
O
HE
O
HE
O
HE
O
HE
O
HE
2'' W 2'' W
2'' W 2'' W
2'' W 2'' W
2'' W
UE UE
UE
UE
UE
F
EN
F
EN
F
EN
F
EN
FE
N
FEN FEN
8''W 8''W 8''W
E
584.49' TP
584.57' TP
584.57' TP
584.57' TP
584.49' TP
584.57' TP
584.57' TP
584.57' TP
584.49' TP
584.49' TP
584.57' TP
584.57' TP
584.57' TP
584.57' TP
2' ' W
2' ' W
2' ' W
2' ' W
2' ' W
BACKFLOW PREVENTER
VALVE BOX
WV
W E
Feet
0 20 40
C-107
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
I L
R G
D E
S I G
N E
D
B
Y
M S
U L L I V
A N
D R
A W
N
B
Y
M
S
U L
L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I L
L
A S
H
P
M E
M O
R I A
L
P
A R
K
P R
O P
S
I T
E
P
L A
N
N
O R
T H
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
EX. PLAYGROUND
EX. PLAYGROUND
EX. CONC.
PAD
EX. CONC.
PAD
EX. CONC.
PAD
EX
. C
ON
C.
PA
D
PROPOSED
SPLASH PAD
PROPOSED SIDEWALK
107.64'
115.70'
42.00'
.0 0'
38.06'
.4 0'
6.
EX
. H
M A
PA
RK
IN
G
LO
T
EX. EDGE HMA
NOTES:
1.) THE SPLASH PAD SHALL BE CONSTRUCTED ACCORDING TO MANUFACTURES
SPECIFICATIONS. ALL CONCRETE NOT SPECIFIED BY THE MANUFACTURE SHALL BE A
C-4 MIX WITH A 28 DAY COMPRESSION STRENGTH OF 4,000 PSI.
2.) ALL SIDEWALK SHALL BE 6" THICK STANDARD CONCRETE WITH 6"X6" WELDED WIRE
FABRIC PLACED ON 6" COMPACTED CA-6.
3.) THE 6" PVC STORM SEWER PIPE FROM THE SPLASH PAD TO THE PURPOSED BERM
MUST MAINTAIN A MINIMUM SLOPE OF 1.00%. THE CURRENT PIPE LENGTH AND
SLOPE INFORMATION WAS DESIGNED TO ACHIEVE A MINIMUM COVER OF 2' OVER
THE PIPE. THE INLET INVERT OF THE 6" PVC STORM SEWER SHALL CONFORM TO THE
MANUFACTURES SPECIFICATIONS.
4.) ALL DISTURBED AREAS SHALL BE HYDRO SEEDED AND MULCHED.
5.) TP = TOP OF PAVEMENT FINISH GRADE
6.) THE FINISHED GRADE (GRASS AREA) SHALL BE SLOPE AWAY FROM SPLASH PAD AT
20:1 OR GREATER.
7.) SURVEY CONTROL WILL BE PROVIDED BY THE ROCK ISLAND ARSENAL DEPARTMENT
OF PUBLIC WORKS.
EX
. C O
NC
PA
D
5.00'
5.00'
2.84'
7.02' 2.84'
24.06'
PARK BENCH PAD
TYP.
R-5'
R-5'
R-5'
R-5'
5.
5.00'
5.
HYDRO SEED AND FERTILIZE = 0.04 AC
HYDRO SEED AND FERTILIZE = 0.27 AC
MATCH LINE MATCH LINE
HYDRO SEED & FERT. = .02 AC
57.69'
.71
.8 2'
52.85'
SPLASH PAD CONC., 102.67 SY
SIDEWALK, PCC, 6" THICKNESS, 161.93 SY
O
HE
O
HE
O
HE
O
HE
O
HE
O
HE
O
HE
O
HE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
U E
OHE
OHE
2'' W 2'' W
2'' W 2'' W
2'' W 2'' W
2'' W 2'' W
UE
UE
UE
UE
U E
FE
N
F
EN
F
EN
F
EN
319.93' of 6" PVC @ 2.76%
E
E
E
T
584.49' TP
584.57' TP
584.57' TP
584.57' TP
584.49' TP
584.57' TP
584.57' TP
584.57' TP
584.49' TP
584.49' TP
584.57' TP
584.57' TP
583.57' TP
583.53' TP
584.57' TP
584.57' TP
2' ' W
2' ' W
2' ' W
W E
Feet
0 25 50
C-108
D A
T E
A P
P R
M
A R
K D
E S
C R
I P
T I O
N
S U
B M
I T
T E
D
B
Y
I S
S U
E
D
A T
E
P R
O J E
D R
A W
I N
G
N
O
U S
A
R M
Y
G
A R
R I S
O
L A
S
E N
A L
D I R
E C
T O
R A
P
U B
L
R
K S
R O
L A
N D
R G
D E
S I G
N E
D
B
Y
M S
U L
L I V
A N
D R
A W
N
B
Y
M
S
U L
L I V
A N
C H
E C
K E
D
B
Y
C S
B
A P
P R
O V
G
K
O S
K I
D
I R
E C
T O
R
O
F
P
U B
L
R
K S
S
B
A C
H
C
H I E
F
O
F
E
N G
I N
E E
R I
U
I L
L
A S
H
P
M E
M O
R I A
L
P
A R
K
P R
O P
S
I T
E
P
L A
N
S
O U
T H
2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
EX. CONC.
PAD
EX. HMA PARKING LOT
NOTES:
1.) SEE BERM TYPICAL ON SHEET C-101 FOR CONSTRUCTION DETAILS.
2.) SEE SHEET FOR C-103 FOR GRADATIONS.
3.) TRESS SHALL NOT BE DISTURBED.
EX. CONC.
PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.PAD
EX. CONC.
PAD
EX
. C
ON
C.
PA
D
EX
. C O
NC
PA
D
LOCATION OF THE EX. SPETIC
TANK HAS NOT BEEN VERIFIED
APPROX LOCATION BASED ON
HISTORICAL MAPS.
EX. CONC. DUMPSTER PAD
END OF 6" PVC
END INVERT = 572.85'
EX. 18" CLAY STRM SWR
INV. IN = 571.62'
GRADE AREA TO IMPROVE
RUNOFF TOWARD BERM
PLACE 2' X 3' X 1'
EROSION STONE
0.5 TONS
TOE OF BERM
TOP OF BERM TOE OF BERM
BOUNDARY OF GRADED AREA
HYDRO-SEED & MULCH = 0.10 AC
CL 13 EXCAVATION = 33.40 CY (FILL)
HYDRO-SEED & MULCH
PIPE AREA = 0.02 AC
PLACE EROSION STONE
FROM TOP OF BERM TO FLOWLINE
OF STORM SEWER PIPE
= 9.5 TONS* FG = FINISHED GRADE
UE
UE
UE
UE
2'' W 2'' W
2'' W
2'' HDPE << 2'' HDPE << 2'' HDPE << 2'' HDPE <<
2''
HD
PE
10.07' of 3" PVC @ 4.38%
INLET INV. = 572.19'
OUTLET INV. = 571.75'
BUILDING
(EX. RESTROOMS)
ABANDON SEPTIC
TANK
319.81' of 6" @ 2.76%
E
E
18'' VC >>
572.98' FG
572.94' FG
572.84' FG
572.62' FG
572.48' FG
PANEL: "EXISTING" FED BY: "T405" MCB 400A BREAKER MTG: PLUG-ON
VOLTAGE: 120/240V BUS: 400A ENCLOSURE: NEMA 3R
1 PHASE,3W + GND BUS TYPE: CU ACCESSORIES:
MOUNTING: SURFACE AIC RATING: 10k
KVA KVA BKR CKT PHASE CKT BKR KVA KVA
PHASE PHASE DESCRIPTION SIZE NO. AB NO. SIZE DESCRIPTION PHASE PHASE
code A B A B code
0 2.00 EXISTING 125A 1 _^*_____^_ 2 90A EXISTING 2.00 2
0 2.00 2P 3 _^__*___^_ 4 2P 2.00 2
0 0.50 EXISTING 30A 5 _^*_____^_ 6 125A EXISTING 2.00 2
0 0.50 2P 7 _^__*___^_ 8 2P 2.00 2
0 0.30 EXISTING 100A 9 _^*_____^_ 10 60 EXISTING 2.00 2
0 0.30 2P 11 _^__*___^_ 12 2P 2.00 2
0 1.00 EXISTING 60A 13 _^*_____^_ 14 30A EXISTING 0.50 2
0 1.00 2P 15 _^__*___^_ 16 2P 0.50 2
PROVIDE NEW 17 _^*_____^_ 18 2
GFCI CIRCUIT BREAKER 19 _^__*___^_ 20 SPACE WITH BUSS
SPACE WITH BUSS 21 _^__*___^_ 22 SPACE WITH BUSS
SPACE WITH BUSS 23 _^__*___^_ 24 SPACE WITH BUSS
25 _^__*___^_ 26 27 _^*_____^_ 28 29 _^__*___^_ 30 31 _^__*___^_ 32 33 _^*_____^_ 34 35 _^__*___^_ 36 37 _^__*___^_ 38 39 _^__*___^_ 40 41 _^__*___^_ 42
10.30 10.30 TOTAL CONNECTED KVA PER PHASE
85.83 85.83 TOTAL CONNECTED AMPS PER PHASE
20.60 TOTAL CONNECTED KVA 85.83 TOTAL CONNECTED AMPS
23.85 TOTAL NEC COMPLIANCE KVA 99.38 TOTAL NEC COMPLIANCE AMPS
TOTAL NEC COMPLIANCE
CODE LOAD CONN(KVA) LIGHTING @ 1.25% 16.25
0 REC= 7.60 FIRST 10 KVA @ 100%= 7.60
1 CLG= 0.00 REMAING REC@ 50%= 0.00
2 LTG= 13.00
3 not used 0.00 4 not used 0.00 KVA @ 240V/1PH = 23.85
5 MTR= 0.00 AMPS= 99
6 not used 0.00 7 not used 0.00
TOTALS 20.60
Existing As Build Condition
T405 XFMR 75 kVA Secondary Voltatge 240 V Impedance 1.9 %Z Full Load Amps on Secondary of XFMR 312.5 I (f.l.) amps M = 100 / I (f.l) = 52.6 I (S.C.) @ T405 SECONDARY = 16447 amps
BUSSMAN TABLE OF C VALUES: #4/0 CU. 12542
MINIMUM CABLE LENGTH (FT.) 25
f = (2 x L x I (S.C.)) / (C x V) = 0.3 M = 1 / (1+ f) = 0.8 I (S.C.) = I (S.C.) T405 x M 12918 amps
New Work Condition
T405 XFMR 75 kVA Secondary Voltatge 240 V Impedance 1.9 %Z Full Load Amps on Secondary of XFMR 312.5 I (f.l.) amps M = 100 / I (f.l) = 52.6 I (S.C.) @ T405 SECONDARY = 16447 amps
BUSSMAN TABLE OF C VALUES: #4/0 CU. 17492
MINIMUM CABLE LENGTH (FT.) 25
f = (2 x L x I (S.C.)) / (C x V) = 0.2 M = 1 / (1+ f) = 0.8 I (S.C.) = I (S.C.) T405 x M 13753 amps
I (S.C.) = Fuse let through current 4000 amps 400 amp LPN-RK Class RK1 Time- Delay
| Sheets and Views |
| Model |
| 2022-102 G-002.pdf |
| Sheets and Views |
| PLOT |
| Splash Pad Civil Design 12-21-21.pdf |
| Sheets and Views |
| Ex.Topo 12-6-21-Quantities |
| Ex.Topo 12-6-21-Est. Ref Info |
| Ex.Topo 12-6-21-General Notes |
| Ex.Topo 12-6-21-Ex-1 |
| Ex.Topo 12-6-21-Ex-2 |
| Ex.Topo 12-6-21-Prop-1 |
| Ex.Topo 12-6-21-Prop-2 |
| Ex.Topo 12-6-21-Prop-3 |
| ELEC Splashpad full size.pdf |
| E101 ONE-LINE Ansi D |
| E102 SITE POWER Ansi D |
File details come from the government source that posted it. Updated .