Feb 2025 CTD.pdf

PDF 2 MB Posted

Attached to
Dugway Proving Ground (DPG) West Desert Test Center (WDTC) Mission Support Services (MSS)
Solicitation number
W51EW725RA001
Issued by

About this file

This is a presentation for an Industry Day event scheduled for February 5, 2025, focused on the Chemical Test Division's facilities and capabilities at what appears to be Dugway Proving Ground. The presentation outlines multiple specialized testing facilities including the Combined Chemical Test Facility (CCTF), Chemical Test Facility (RAIL), Materiel Test Facility (MTF), and Decontamination Facilities.

The facilities described include 35,000 square feet of multifunctional laboratories with 47 agent-certified fume hoods, specialized test chambers for chemical warfare agents and simulants, and decontamination facilities with a 200' x 100' steel-reinforced concrete pad capable of handling armored vehicles. The presentation highlights support for the JPEO-CBRND programs including the Aerosol and Vapor Chemical Agent Detector (AVCAD) and Multi-Purpose Chemical Agent Detector (MPCAD). Key regulations referenced include AR 50-6, AR 190-59, and DA Pam 385-61, with the facility being ISO 17025 certified for safety air monitoring and hazardous waste handling. The primary customer is identified as the Joint Program Executive Office for Chemical, Biological, Radiological, and Nuclear Defense (JPEO-CBRND).

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDUSTRY DAY

Chemical Test Division 05 FEB 2025

U.S. ARMY TEST AND EVALUATION COMMAND 2

[CLASSIFICATION]

COMBINED CHEMICAL TEST FACILTY

(CCTF)

Capabilities

• 35,000 ft2 of multifunctional laboratories

• 47 agent-certified fume hoods in 27 surety-capable test suites

• Supports chamber and field testing of chem-bio defense systems

• Aerosol, vapor, and droplet testing with CWA, TIC/TIM, & emerging threats

• Developmental and operational testing

Live Agent & Simulant Testing

U.S. ARMY TEST AND EVALUATION COMMAND 3

CHEMICAL TEST FACILITY (RAIL)

Fixture Description Novel Closures Test Fixture Test closures and seams used in ColPro structures Advanced Air-Purification Test Fixture (AAPTF) Test full-scale ColPro air filtration devices w/agent Chamber Rail System (CRS) Testing a surface detector with agent on various surfaces while on-the-move

Two 2,210-ft2 Custom-tailored Test Chambers that Allow High Concentrations of Chemical Warfare Agents or Chemical And

Biological Simulants

U.S. ARMY TEST AND EVALUATION COMMAND 4

DECONTAMINATION FACILITIES

• All DPG permitted simulants and decontaminants allowed

• Steel-reinforced concrete pad (200’ x 100’)

• 20-foot walls for overspray mitigation

• 8 feet above grade

• Can handle weight of armored vehicles

• Sump, pump system, and holding tank for waste disposal

• Multiple power ratings

• Multiple water options

Operational Use

• Test effectiveness of contamination/decontamination cycles

• Decon operating procedure training

• Test accuracy of chem/bio point detectors

• Environmentally friendly

Full-Scale Decontamination Testing

U.S. ARMY TEST AND EVALUATION COMMAND 5

MATERIEL TEST FACILITY (MTF)

Chamber Test Fixture 30’x25’x25’ Chamber Chemical Agent Vapor (CAV)

Fixtures 1, 2 and 3 30’x25’x25’ Chamber Agent storage 30’x50’x50’ Chamber

Secondary Containment Module (SCM) #1

Liquid Aerosol Detection Fixture (LADF) Particulate Aerosol Detection Fixture

(PADF)

SCM #2 Advanced Threat Vapor Fixture (ATVF)

Supporting the JPEO-CBRND Aerosol and Vapor Chemical Agent Detector (AVCAD) and the Multi-Purpose Chemical Agent Detector (MPCAD) programs

Three Large and Versatile Stainless Steel Chemical Agent Chambers and Removable Secondary Containment Modules

U.S. ARMY TEST AND EVALUATION COMMAND 6

BANG BOX (CZ TOC) & TOMBSTONE

FIELD TEST & TRAINING EXERCISE SUPPORT

Test Team Briefing Room / NET Training

Climate Controlled TOC Test Support / Black Out Area

System Under Test (SUT) Configuration

Walking distance from NET Training / SUT Config. To Test Bed

On Site Sample Extraction Laboratory

U.S. ARMY TEST AND EVALUATION COMMAND 7

OTHER NOTES

▪ Chemical Personnel Reliability Program

▪ Surety regulations: AR 50-6, AR 190-59, DA Pam 385-61

▪ 17025 ISO certified: Safety air monitoring, Haz waste

▪ Primary customer: Joint Program Executive Office for Chemical, Biological, Radiological, and Nuclear Defense (JPEO-CBRND)

THANK YOU.

Industry Day
Combined Chemical Test Facilty (CCTF)
Chemical Test Facility (RAIL)
Decontamination Facilities
Materiel Test Facility (MTF)
Slide Number 6
Other notes
Slide Number 8

File details come from the government source that posted it. Updated .