About this file

This solicitation seeks bids for alteration work on an F-35 aircraft hangar at Truax Field in Madison, Wisconsin. The project scope includes demolishing 19,913 square feet of existing hangar space to be reconfigured for F-35 maintenance operations, including lavatories, offices, break rooms, mechanical spaces, and repair shops. An additional 19,803 square feet of hangar space will be modified to accommodate F-35 aircraft, incorporating a high expansion foam fire suppression system, aircraft make-up power and air systems, and lightning protection. Interested contractors must register in the System for Award Management and attend a mandatory pre-bid conference on February 16, 2021. Bids are due by March 8, 2021, with award being made to the responsive and responsible lowest bidder. The contract duration is 365 days from notice to proceed. The solicitation and plans are available through the SAM.gov website.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 Alter Hangar 406, newest first.
File Type Posted
C-102_Add03.pdf PDF
C-101_Add03.pdf PDF
Specs TOC_Add03.pdf PDF
01 50 00_Add03.pdf PDF
W50S9F21B00010005.pdf PDF
C-121_Add03.pdf PDF
C-504_Add03.pdf PDF
34 71 13.19_Add03.pdf PDF
01 45 00.00 10_Add03.pdf PDF
22 31 00_Add03.pdf PDF
T-121 Add03.pdf PDF
Specs TOC_ Add02.pdf PDF
A-301_Add02.pdf PDF
A-901_Add02.pdf PDF
A-801_Add02.pdf PDF
A-101_Add02.pdf PDF
01 45 00.00 10_Add02.pdf PDF
Asbestos and Lead Inspection.pdf PDF
Repair Roofs 406 Warranty Cert.pdf PDF
A-401_Add02.pdf PDF
04 20 00_Add02.pdf PDF
A-501_Add02.pdf PDF
A-601_Add02.pdf PDF
02 83 00_Add02.pdf PDF
01 14 00_Add02.pdf PDF
01 11 00_Add02.pdf PDF
406 Questions and Answers_26-112.pdf PDF
G-001_Add02.pdf PDF
E-101_Add02.pdf PDF
406 Questions and Answers_1-25.pdf PDF
Specs TOC_Add01.R1.pdf PDF
07 24 00_Add01.R1.pdf PDF
09 67 23.13_Add01.R1.pdf PDF
32 92 19_Add01.R1.pdf PDF
C-101_Add01.R1.pdf PDF
Geotechnical Report_Add01.R1.pdf PDF
07 27 26_Add01.R1.pdf PDF
A-131_Add01.R1.pdf PDF
C-121_Add01.R1.pdf PDF
W50S9F21B00010002.pdf PDF
B.07.406 Site Visit Sign In 19Feb21.pdf PDF
Pre-Bid Slides - F-35 406.pptx PPTX presentation
406 Site Visit Sign In.pdf PDF
W50S9F21B00010001.pdf PDF
ATTACHMENT 2-Truax F-35 B406 XGFG182008 Specs Vol 2 of 2 Dated 31 July 2020.pdf PDF
ATTACHMENT 3-Truax F35 B406 XGFG182008 Plans Dated 31 July 2020.pdf PDF
ATTACHMENT 7-Justification and Approval Best Lock.pdf PDF
ATTACHMENT 4-Justification and Approval Advantor.pdf PDF
ATTACHMENT 1-Truax F-35 B406 XGFG182008 Specs Vol 1 of 2 Dated 31 July 2020.pdf PDF
ATTACHMENT 5-Justification and Approval Andover.pdf PDF
Show all 50

F-35 Alter Hangar 406 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

100'-0"

T.O. UPPER WALL

117'-4"

HANGAR EAVE

130'-11"

R0R2R4R6R810L8L6L4L2L0LDP R1R3R5R7R9L9L7L5L3L1

A-301

A-301

4.204

4.204

4.205

W3

A-311

4.204

4.204

4.212

4.201

4.213

4.212

4.212

4.212 4.216

4.2184.218

4.218

4.107

4.2214.221

4.2214.221

FIRST FLOOR

100'-0"

T.O. UPPER WALL

117'-4"

HANGAR EAVE

130'-11"

R0 R2 R4 R6 R8 10 L8 L6 L4 L2 L0 LDPR1 R3 R5 R7 R9 L9 L7 L5 L3 L1

A-301

A-301

4.202

4.204

4.203

4.205

W3 W3 W4 W3 W3 W3

A-311

4.203

4.2024.202

4.203

4.212

4.212

4.212

4.201

4.201

4.201

4.107

4.107

4.218

4.120

4.220

SHEET NO.:

SHEET CONTENTS

DO NOT SCALE DRAWINGS

M&H NO.:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ISSUED

© Copyright This document, or any portion thereof, shall not be duplicated, disclosed, or used on any other project or extension of this project except by written agreement with Mead & Hunt, Inc. Mead & Hunt shall not be responsible for any unauthorized use of, or alteration to these documents.

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com

/2

/2

:0

:1

A

M C

R e v it L o c a l\

-1

.0

-A

-C e n tr a l-p jc

.r v t

T R

U A

X F

IE

L D

A N

G B

M A

D

IS

O N

W

I

F -3

A L T

E R

B U

IL

D

IN

G

A-201

EXTERIOR

ELEVATIONS

XGFG182008ANG NO.:

3141300-190289.01

BAE

JJB

July 31, 2020

PJC

1/8" = 1'-0"1

NORTH BUILDING ELEVATION

1/8" = 1'-0"2

SOUTH BUILDING ELEVATION

KEYED NOTES

4.107 GUARDRAIL / HANDRAIL, PAINTED, SEE DETAIL 3/A-402

4.120 EXISTING ROOF ACCESS LADDER TO REMAIN, PROVIDE NEW FALL

PROTECTION SYSTEM TO LADDER

4.201 NEW 1 1/2" METAL SIDING, FASTEN TO EXISTING SUPPORTS, SEE 15/ A-501

4.202 4" SPLIT FACE BLOCK VENEER (SEE SPECS).

4.203 PRECAST SILL (SEE SPECS).

4.204 3" EIFS WALL SYSTEM

4.205 EXISTING PRE-FINISHED METAL FASCIA TRIM REMOVE AND REPLACE AS

NEED FOR INSTALLATION OF NEW EIFS SYSTEM (SEE SPECS).

4.212 EXISTING ROOF TO REMAIN

4.213 EXISTING HANGAR DOOR TO REMAIN, CLEAN PATCH AND REPAIR ANY

EXISTING HOLES OR DAMAGE PRIOR TO APPLYING NEW PAINT FINISH TO

MATCH.

4.216 FASCIA TO MATCH EXISTING CANOPY, SEE 16/A-501 AND STRUCTURAL

DRAWINGS.

4.218 NEW METAL PIPE BOLLARD, PAINTED, SEE STRUCTURAL DRAWINGS

4.220 PROVIDE NEW BUILDING IDENTIFICATION SIGN. 9" HIGH (HELVETICA NEVE 85

BOLD) LETTERFORM IN DARK BRONZE, LETTERFORMS TO BE MIN 3/4" CAST

ALUMINUM MOUNTED TO BUILDING ON STUDS.

4.221 PROVIDE HIGH IMPACT RESISTANT EIFS WHERE EXPOSED TO PEDESTRIAN

AND VEHICULAR TRAFFIC AND NOT PROTECTED BY MASONRY VENEER, UP

TO FIRST REVEAL , APPROX 7'-8" ABOVE GRADE,

07/31/20 TYPE B3 FINAL

1 02/26/21 ADDENDUM - 01

Sheets
A-201 - EXTERIOR ELEVATIONS

File details come from the government source that posted it. Updated .