This solicitation is for a 3D printer room upgrade project at Rickenbacker Air Base in Columbus, Ohio. The project involves modifications to facility Room 112 such as installing a new 50 amp power supply, additional overhead lighting, and a double-door access point. The project value is estimated between $25,000 to $100,000. It will be competitively solicited as a small business set-aside. The solicitation method is sealed bidding based on price factors only, with an award going to the responsible bidder offering the most advantageous price. The period of performance is 120 days, though power and door work must be completed within approximately 35 days of contract award in preparation for printer delivery. The soliciting agency is the Department of the Army National Guard.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USACE / NAVFAC / AFCEC UFGS- 08 11 13 ( August 2020)
Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 08 11 13 ( Febr uar y 2010)
UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS
Ref er ences ar e i n agr eement wi t h UMRL dat ed Oct ober 2023
SECTI ON TABLE OF CONTENTS
DI VI SI ON 08 - OPENI NGS
SECTI ON 08 11 13
STEEL DOORS AND FRAMES
08/ 20
PART 1 GENERAL
1. 1 REFERENCES
1. 2 SUBMI TTALS
1. 3 DELI VERY, STORAGE, AND HANDLI NG
PART 2 PRODUCTS
2. 1 STANDARD STEEL DOORS
2. 1. 1 Cl assi f i cat i on - Level , Per f or mance, Model
2. 1. 1. 1 St andar d Dut y Door s
2. 1. 1. 2 Heavy Dut y Door s
2. 1. 1. 3 Ext r a Heavy Dut y Door s
2. 1. 1. 4 Maxi mum Dut y Door s
2. 2 CUSTOM HOLLOW METAL DOORS
2. 3 I NSULATED STEEL DOOR SYSTEMS
2. 4 ACCESSORI ES
2. 4. 1 Shel ves f or Dut ch Door s
2. 4. 2 Louver s
2. 4. 2. 1 I nt er i or Louver s
2. 4. 2. 2 Ext er i or Louver s
2. 4. 3 Ast r agal s
2. 4. 4 Mol di ngs
2. 5 I NSULATI ON CORES
2. 6 STANDARD STEEL FRAMES
2. 6. 1 Wel ded Fr ames
2. 6. 2 Knock- Down Fr ames
2. 6. 3 Mul l i ons and Tr ansom Bar s
2. 6. 4 St ops and Beads
2. 6. 5 Ter mi nat ed St ops
2. 6. 6 Cased Openi ngs
2. 6. 7 Anchor s
2. 6. 7. 1 Wal l Anchor s
2. 6. 7. 2 Fl oor Anchor s
SECTI ON 08 11 13 Page 1
2. 7 FI RE [ AND] [ SMOKE] DOORS AND FRAMES
2. 7. 1 Label s
2. 7. 2 Over si zed Door s
2. 7. 3 Ast r agal on Fi r e [ and Smoke] Door s
2. 8 EXTERI OR FRAMES
2. 9 HARDWARE PREPARATI ON
2. 10 FI NI SHES
2. 10. 1 Fact or y- Pr i med Fi ni sh
2. 10. 2 Hot - Di p Zi nc- Coat ed and Fact or y- Pr i med Fi ni sh
2. 10. 3 El ect r ol yt i c Zi nc- Coat ed Anchor s and Accessor i es
2. 10. 4 Fact or y- Appl i ed Enamel Fi ni sh
2. 11 FABRI CATI ON AND WORKMANSHI P
2. 12 PROVI SI ONS FOR GLAZI NG
PART 3 EXECUTI ON
3. 1 I NSTALLATI ON
3. 1. 1 Fr ames
3. 1. 2 Door s
3. 1. 3 Fi r e [ and Smoke] Door s and Fr ames
3. 2 PROTECTI ON
3. 3 CLEANI NG
- - End of Sect i on Tabl e of Cont ent s - -
SECTI ON 08 11 13 Page 2
USACE / NAVFAC / AFCEC UFGS- 08 11 13 ( August 2020)
Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 08 11 13 ( Febr uar y 2010)
UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS
Ref er ences ar e i n agr eement wi t h UMRL dat ed Oct ober 2023
SECTI ON 08 11 13
STEEL DOORS AND FRAMES
08/ 20
NOTE: Thi s gui de speci f i cat i on cover s st eel door s and f r ames. Some par agr aphs may need t o be suppl ement ed t o meet pr oj ect r equi r ement s.
I ncl ude Sect i on 08 34 73 SOUND CONTROL DOOR ASSEMBLI ES when pr oj ect i ncl udes f l ush st eel sound r et ar dant door s wi t h Sound Tr ansmi ssi on Cl assi f i cat i on ( STC) r angi ng f r om 25 t o 45.
Adher e t o UFC 1- 300- 02 Uni f i ed Faci l i t i es Gui de Speci f i cat i ons ( UFGS) For mat St andar d when edi t i ng t hi s gui de speci f i cat i on or pr epar i ng new pr oj ect speci f i cat i on sect i ons. Edi t t hi s gui de speci f i cat i on f or pr oj ect speci f i c r equi r ement s by addi ng, del et i ng, or r evi s i ng t ext . For br acket ed i t ems, choose appl i cabl e i t em( s) or i nser t appr opr i at e i nf or mat i on.
Remove i nf or mat i on and r equi r ement s not r equi r ed i n r espect i ve pr oj ect , whet her or not br acket s ar e pr esent .
Comment s, suggest i ons and r ecommended changes f or t hi s gui de speci f i cat i on ar e wel come and shoul d be submi t t ed as a Cr i t er i a Change Request ( CCR) .
NOTE: On t he dr awi ngs, show:
1. Si zes of door openi ngs, t hi cknesses of door s, swi ngs, and t r avel s of door s, and desi gn of door s, whet her f l ush panel , f ul l f l ush, panel ed, gl azed, or l ouver ed. I t i s r ecommended t hat st andar d door - t ype nomencl at ur e, SDI 106, be used t o i ndi cat e desi gns ( e. g. , F, L, G, GL i n l i eu of A, B, C) .
2. Det ai l s of nonst r uct ur al mul l i ons, mul l i on cover s, and r emovabl e mul l i ons.
SECTI ON 08 11 13 Page 3
3. Type and t hi ckness of gl azi ng r equi r ed; whet her or not i nsul at i ng gl ass uni t s ar e r equi r ed.
4. Met hod, t ype, and spaci ng r equi r ed f or anchor i ng door f r ames t o adj oi ni ng const r uct i on.
5. Li nt el s and r ei nf or cement r equi r ed t o suppor t wal l s or par t i t i ons above door s.
6. Type of shop f i ni sh on st eel sur f aces.
7. Fr ee ar ea f or l ouver s i n door s.
8. Compl et e door schedul e. Schedul e shoul d assi gn a separ at e number f or each openi ng and shoul d i ndi cat e door t ype and st y l e, mat er i al , desi gn, s i ze, t hi ckness, gl azed or ungl azed, c l ass f i r e r at i ng f or f i r e door s, har dwar e set number , t hr eshol d mat er i al , i f any, and mat er i al f or f r ames, mul l i ons, and t r ansom bar s.
PART 1 GENERAL
1. 1 REFERENCES
NOTE: Thi s par agr aph i s used t o l i s t t he publ i cat i ons c i t ed i n t he t ext of t he gui de speci f i cat i on. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by basi c desi gnat i on onl y and l i s t ed i n t hi s par agr aph by or gani zat i on, desi gnat i on, dat e, and t i t l e.
Use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e when you add a Ref er ence I dent i f i er ( RI D) out si de of t he Sect i on' s Ref er ence Ar t i c l e t o aut omat i cal l y pl ace t he r ef er ence i n t he Ref er ence Ar t i c l e. Al so use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e t o updat e t he i ssue dat es.
Ref er ences not used i n t he t ext wi l l aut omat i cal l y be del et ed f r om t hi s sect i on of t he pr oj ect speci f i cat i on when you choose t o r econci l e r ef er ences i n t he publ i sh pr i nt pr ocess.
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN WELDI NG SOCI ETY ( AWS)
AWS D1. 1/ D1. 1M ( 2020; Er r at a 1 2021) St r uct ur al Wel di ng Code - St eel
SECTI ON 08 11 13 Page 4
ASTM I NTERNATI ONAL ( ASTM)
ASTM A653/ A653M ( 2023) St andar d Speci f i cat i on f or St eel Sheet , Zi nc- Coat ed ( Gal vani zed) or Zi nc- I r on Al l oy- Coat ed ( Gal vanneal ed) by t he Hot - Di p Pr ocess
ASTM A879/ A879M ( 2012; R 2017) St andar d Speci f i cat i on f or St eel Sheet , z i nc Coat ed by t he El ect r ol yt i c Pr ocess f or Appl i cat i ons Requi r i ng Desi gnat i on of t he Coat i ng Mass on Each Sur f ace
ASTM A924/ A924M ( 2022a) St andar d Speci f i cat i on f or Gener al Requi r ement s f or St eel Sheet , Met al l i c- Coat ed by t he Hot - Di p Pr ocess
ASTM C578 ( 2022) St andar d Speci f i cat i on f or Ri gi d, Cel l ul ar Pol yst yr ene Ther mal I nsul at i on
ASTM C591 ( 2022) St andar d Speci f i cat i on f or Unf aced Pr ef or med Ri gi d Cel l ul ar Pol y i socyanur at e Ther mal I nsul at i on
ASTM C612 ( 2014; R 2019) St andar d Speci f i cat i on f or Mi ner al Fi ber Bl ock and Boar d Ther mal I nsul at i on
ASTM D2863 ( 2019) St andar d Test Met hod f or Measur i ng t he Mi ni mum Oxygen Concent r at i on t o Suppor t Candl e- Li ke Combust i on of Pl ast i cs ( Oxygen I ndex)
ASTM E1300 ( 2016) St andar d Pr act i ce f or Det er mi ni ng Load Resi st ance of Gl ass i n Bui l di ngs
ASTM F2247 ( 2018) St andar d Test Met hod f or Met al Door s Used i n Bl ast Resi st ant Appl i cat i ons ( Equi val ent St at i c Load Met hod)
ASTM F2248 ( 2012) St andar d Pr act i ce f or Speci f y i ng an Equi val ent 3- Second Dur at i on Desi gn Loadi ng f or Bl ast Resi st ant Gl azi ng Fabr i cat ed wi t h Lami nat ed Gl ass
ASTM F2927 ( 2012) St andar d Test Met hod f or Door Syst ems Subj ect t o Ai r bl ast Loadi ngs
BUI LDERS HARDWARE MANUFACTURERS ASSOCI ATI ON ( BHMA)
ANSI / BHMA A156. 115 ( 2016) Har dwar e Pr epar at i on i n St eel Door s and St eel Fr ames
NATI ONAL ASSOCI ATI ON OF ARCHI TECTURAL METAL MANUFACTURERS ( NAAMM)
NAAMM HMMA 810 ( 2009) Hol l ow Met al Door s
SECTI ON 08 11 13 Page 5
NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)
NFPA 80 ( 2022) St andar d f or Fi r e Door s and Ot her Openi ng Pr ot ect i ves
NFPA 105 ( 2022) St andar d f or Smoke Door Assembl i es and Ot her Openi ng Pr ot ect i ves
NFPA 252 ( 2022) St andar d Met hods of Fi r e Test s of Door Assembl i es
STEEL DOOR I NSTI TUTE ( SDI / DOOR)
SDI / DOOR 111 ( 2009) Recommended Det ai l s f or St andar d St eel Door s, Fr ames, and Accessor i es and Rel at ed Component s
SDI / DOOR 113 ( 2023) St andar d Pr act i ce f or Det er mi ni ng t he St eady- St at e Ther mal Tr ansmi t t ance of St eel Door and Fr ame Assembl i es
SDI / DOOR A250. 3 ( 2019) Test Pr ocedur e and Accept ance Cr i t er i a f or Fact or y Appl i ed Fi ni sh Coat i ngs f or St eel Door s and Fr ames
SDI / DOOR A250. 4 ( 2022) Test Pr ocedur e and Accept ance Cr i t er i a f or Physi cal Endur ance f or St eel Door s, Fr ames and Fr ame Anchor s
SDI / DOOR A250. 6 ( 2020) Recommended Pr act i ce f or Har dwar e Rei nf or ci ng on St andar d St eel Door s and Fr ames
SDI / DOOR A250. 8 ( 2023) Speci f i cat i ons f or St andar d St eel Door s and Fr ames
SDI / DOOR A250. 11 ( 2022) Recommended Er ect i on I nst r uct i ons f or St eel Fr ames
U. S. DEPARTMENT OF DEFENSE ( DOD)
UFC 4- 010- 01 ( 2018; wi t h Change 2, 2022) DoD Mi ni mum Ant i t er r or i sm St andar ds f or Bui l di ngs
UNDERWRI TERS LABORATORI ES ( UL)
UL 10C ( 2016; Repr i nt May 2021) UL St andar d f or Saf et y Posi t i ve Pr essur e Fi r e Test s of Door Assembl i es
1. 2 SUBMI TTALS
NOTE: Revi ew Submi t t al Descr i pt i on ( SD) def i ni t i ons i n Sect i on 01 33 00 SUBMI TTAL PROCEDURES and edi t t he f ol l owi ng l i s t , and cor r espondi ng submi t t al i t ems i n t he t ext , t o r ef l ect onl y t he submi t t al s r equi r ed f or t he pr oj ect . The Gui de Speci f i cat i on t echni cal edi t or s have cl assi f i ed t hose i t ems t hat
SECTI ON 08 11 13 Page 6 r equi r e Gover nment appr oval , due t o t hei r compl exi t y or cr i t i cal i t y, wi t h a " G. " Gener al l y, ot her submi t t al i t ems can be r evi ewed by t he Cont r act or ' s Qual i t y Cont r ol Syst em. Onl y add a " G" t o an i t em i f t he submi t t al i s suf f i c i ent l y i mpor t ant or compl ex i n cont ext of t he pr oj ect .
For Ar my pr oj ect s, f i l l i n t he empt y br acket s f ol l owi ng t he " G" c l assi f i cat i on, wi t h a code of up t o t hr ee char act er s t o i ndi cat e t he appr ovi ng aut hor i t y. Codes f or Ar my pr oj ect s usi ng t he Resi dent Management Syst em ( RMS) ar e: " AE" f or Ar chi t ect - Engi neer ; " DO" f or Di st r i ct Of f i ce ( Engi neer i ng Di v i s i on or ot her or gani zat i on i n t he Di st r i ct Of f i ce) ; " AO" f or Ar ea Of f i ce; " RO" f or Resi dent Of f i ce; and " PO" f or Pr oj ect Of f i ce. Codes f ol l owi ng t he " G" t ypi cal l y ar e not used f or Navy and Ai r For ce pr oj ect s.
The " S" c l assi f i cat i on i ndi cat es submi t t al s r equi r ed as pr oof of compl i ance f or sust ai nabi l i t y Gui di ng Pr i nci pl es Val i dat i on or Thi r d Par t y Cer t i f i cat i on and as descr i bed i n Sect i on 01 33 00 SUBMI TTAL
PROCEDURES.
Choose t he f i r st br acket ed i t em f or Navy and Ai r For ce pr oj ect s, or choose t he second br acket ed i t em f or Ar my pr oj ect s.
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" or " S" c l assi f i cat i on. Submi t t al s not havi ng a " G" or " S" c l assi f i cat i on ar e [ f or Cont r act or Qual i t y Cont r ol appr oval . ] [ f or i nf or mat i on onl y. When used, a code f ol l owi ng t he " G" c l assi f i cat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . ] Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:
SD- 02 Shop Dr awi ngs
Door s; G[ , [ _____] ]
Fr ames; G[ , [ _____] ]
Accessor i es
Schedul e of Door s; G[ , [ _____] ]
Schedul e of Fr ames; G[ , [ _____] ]
SD- 03 Pr oduct Dat a
Door s; G[ , [ _____] ]
Recycl ed Cont ent f or St eel Door Pr oduct ; S
Fr ames; G[ , [ _____] ]
Recycl ed Cont ent f or St eel Fr ame Pr oduct ; S
SECTI ON 08 11 13 Page 7
Accessor i es
[ SD- 04 Sampl es
Fact or y- appl i ed Enamel Fi ni sh; G[ , [ _____] ]
] 1. 3 DELI VERY, STORAGE, AND HANDLI NG
Del i ver door s, f r ames, and accessor i es undamaged and wi t h pr ot ect i ve wr appi ngs or packagi ng. [ St r ap knock- down f r ames i n bundl es. ] [ Pr ovi de t empor ar y st eel spr eader s secur el y f ast ened t o t he bot t om of each wel ded f r ame. ] St or e door s and f r ames on pl at f or ms under cover i n c l ean, dr y, vent i l at ed, and accessi bl e l ocat i ons, wi t h 6 mm 1/ 4 i nch ai r space bet ween door s. Remove damp or wet packagi ng i mmedi at el y and wi pe af f ect ed sur f aces dr y. Repl ace damaged mat er i al s wi t h new.
PART 2 PRODUCTS
2. 1 STANDARD STEEL DOORS
NOTE: St andar d st eel door s ar e t he most common and compet i t i vel y pr i ced whi ch appl y t o most met al door openi ngs i n most pr oj ect s. Di f f er ent c l assi f i cat i ons and per f or mance r equi r ement s ar e avai l abl e as expl ai ned i n t he edi t or ' s not es i n par agr aph CLASSI FI CATI ON - LEVEL, PERFORMANCE, MODEL.
NOTE: For f or ced ent r y, i ncl ude t he br acket ed opt i on bel ow r egar di ng ext er i or gl azi ng when per sonnel densi t y i s gr eat er t han one per son per 40 squar e met er s 430 squar e f eet and t he mi ni mum AT/ FP st andof f di st ances ar e met . Thi s does not i ncl ude guar d t ype f aci l i t i es or s i ngl e and dupl ex det ached f ami l y housi ng. These r equi r ement s ar e speci f i ed i n UFC 4- 010- 01 " DoD Mi ni mum Ant i t er r or i sm St andar ds f or Bui l di ngs" . I ncl ude l ast br acket ed sent ence i f ext er i or door s must meet ant i t er r or i sm r equi r ement s of UFC 4- 010- 01.
SDI / DOOR A250. 8, except as speci f i ed ot her wi se. Pr epar e door s t o r ecei ve door har dwar e as speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE. Under cut wher e i ndi cat ed. Pr ovi de ext er i or door s wi t h t op edge cl osed f l ush and seal ed t o pr event wat er i nt r usi on. Pr ovi de door s at 44. 5 mm 1- 3/ 4 i nch t hi ck, unl ess ot her wi se i ndi cat ed. Pr ovi de door mat er i al t hat uses a mi ni mum of 25 per cent r ecycl ed cont ent . Pr ovi de dat a i ndi cat i ng per cent age of r ecycl ed cont ent f or st eel door pr oduct . [ Pr ovi de ext er i or gl azi ng i n accor dance wi t h ASTM F2248 and ASTM E1300. ] [ Ext er i or door s must be t est ed i n accor dance wi t h ASTM F2247 or ASTM F2927 t o meet r equi r ement s of UFC 4- 010- 01. ]
2. 1. 1 Cl assi f i cat i on - Level , Per f or mance, Model
NOTE: When a door l evel i s not r equi r ed, del et e t he ent i r e par agr aph f or t hat l evel . Door l evel s f or
SECTI ON 08 11 13 Page 8 var i ous l ocat i ons shoul d be det er mi ned i n accor dance wi t h SDI 108 Tabl e 2 and t he f ol l owi ng l i s t .
Cl oset door s ( wi t hout l ocks) Level 1 I ndi v i dual of f i ces, st or age r ooms, cl assr ooms, pat i ent s ' r ooms, bat hr ooms, and bedr ooms ( except BEQ bedr ooms) Level 2 BEQ sl eepi ng r oom ent r ance door s and i nt er i or egr ess door s Level 3 Ext er i or Mai n ent r ance and ci r cul at i on door s and ot her l ocat i ons Level 4
Model desi gnat i ons ar e as f ol l ows:
Model 1 Ful l Fl ush Desi gn Model 2 Seaml ess Desi gn Model 3 St i l e and Rai l
Wher e appear ance i s i mpor t ant and edge seams ar e obj ect i onabl e, use Model 2.
Cor e const r uct i ons must be at t he manuf act ur er ' s di scr et i on and ar e as f ol l ows:
a. Kr af t / Paper Honeycomb
b. Pol yur et hane Modi f i ed Pol y i socyanur at e
c. Pol yst yr ene
d. Mi ner al Boar d
e. Ver t i cal St eel St i f f ener s
2. 1. 1. 1 St andar d Dut y Door s
SDI / DOOR A250. 8, Level 1, physi cal per f or mance Level C, Model [ 1] [ 2] , of s i ze( s) and desi gn( s) i ndi cat ed and cor e const r uct i on as r equi r ed by t he manuf act ur er . Pr ovi de [ wher e shown] [ f or door s No. [ _____] ] .
2. 1. 1. 2 Heavy Dut y Door s
SDI / DOOR A250. 8, Level 2, physi cal per f or mance Level B, Model [ 1] [ 2] , wi t h cor e const r uct i on as r equi r ed by t he manuf act ur er [ f or i nt er i or door s] [ and ] [ f or ext er i or door s] , of s i ze( s) and desi gn( s) i ndi cat ed. [ Wher e ver t i cal st i f f ener cor es ar e r equi r ed, t he space bet ween t he st i f f ener s must be f i l l ed wi t h boar d i nsul at i on. ] [ Pr ovi de Level 2 [ wher e i ndi cat ed] [ f or door s No. [ _____] ] . ]
2. 1. 1. 3 Ext r a Heavy Dut y Door s
SDI / DOOR A250. 8, Level 3, physi cal per f or mance Level A, Model [ 1] [ 2] [ 3] wi t h cor e const r uct i on as r equi r ed by t he manuf act ur er [ f or i nt er i or door s] [ and ] [ f or i ndi cat ed ext er i or door s] , of s i ze( s) and desi gn( s) i ndi cat ed. [ Wher e ver t i cal st i f f ener cor es ar e r equi r ed, t he space bet ween t he st i f f ener s must be f i l l ed wi t h boar d i nsul at i on. ] [ Pr ovi de Level 3 [ wher e i ndi cat ed] [ f or door s No. [ _____] ] . ]
2. 1. 1. 4 Maxi mum Dut y Door s
SDI / DOOR A250. 8, Level 4, physi cal per f or mance Level A, Model [ 1] [ 2] wi t h
SECTI ON 08 11 13 Page 9 cor e const r uct i on as r equi r ed by t he manuf act ur er [ f or i nt er i or door s] [ and ] [ f or i ndi cat ed ext er i or door s] , of s i ze( s) and desi gn( s) i ndi cat ed. [ Wher e ver t i cal st i f f ener cor es ar e r equi r ed, t he space bet ween t he st i f f ener s must be f i l l ed wi t h boar d i nsul at i on. ] [ Pr ovi de Level 4 [ wher e i ndi cat ed] [ f or door s No. [ _____] ] . ]
[ 2. 2 CUSTOM HOLLOW METAL DOORS
NOTE: Cust om st eel door s ar e t ypi cal l y schedul ed i n l ocat i ons t hat ( 1) r equi r e uni que di mensi ons t hat ar e over si zed, non- st andar d, or l ocat ed i n speci al use bui l di ngs or r et r of i t s, ( 2) r equi r e enhanced per f or mance f r om weat her , sound r educt i on, f or ced ent r y, bul l et r esi st ant , or bl ast door s, or ( 3) r equi r e speci f i c aest het i cs t hat r equi r e embossment s, at t r act i ve panel s or ot her cust omi zat i on possi bl y f or hi st or i c or ot her i nst al l at i ons. Wher e onl y st andar d st eel door s ar e used i n a pr oj ect , del et e t hi s par agr aph.
NOTE: For f or ced ent r y, i ncl ude t he br acket ed opt i on bel ow r egar di ng ext er i or gl azi ng when per sonnel densi t y i s gr eat er t han one per son per 40 squar e met er s 430 squar e f eet and t he mi ni mum AT/ FP st andof f di st ances ar e met . Thi s does not i ncl ude guar d t ype f aci l i t i es or s i ngl e and dupl ex det ached f ami l y housi ng. These r equi r ement s ar e speci f i ed i n UFC 4- 010- 01 " DoD Mi ni mum Ant i t er r or i sm St andar ds f or Bui l di ngs" . I ncl ude l ast br acket ed sent ence i f ext er i or door s must meet ant i t er r or i sm r equi r ement s of UFC 4- 010- 01.
Pr ovi de cust om hol l ow met al door s wher e nonst andar d st eel door s ar e i ndi cat ed. Pr ovi de cust om st eel door s i n t he door s i ze( s) , desi gn( s) , mat er i al s, const r uct i on, gages, and f i ni sh as speci f i ed f or cust om st eel door s and compl yi ng wi t h t he r equi r ement s of NAAMM HMMA 810. Fi l l al l spaces i n ext er i or door s wi t h i nsul at i on. Cl ose t op and bot t om edges wi t h st eel channel s not l i ght er t han 1. 5 mm t hi ck 16 gage. [ Cl ose t ops of ext er i or door s f l ush wi t h an addi t i onal channel and seal t o pr event wat er i nt r usi on. ] Pr epar e door s t o r ecei ve har dwar e speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE. [ Under cut door s wher e i ndi cat ed. ] Pr ovi de door s at 44. 5 mm 1- 3/ 4 i nch t hi ck, unl ess ot her wi se i ndi cat ed. [ Pr ovi de ext er i or gl azi ng i n accor dance wi t h ASTM F2248 and ASTM E1300. ] [ Ext er i or door s much be t est ed i n accor dance wi t h ASTM F2247 and ASTM F2927 t o meet t he r equi r ement s of UFC 4- 010- 01. ]
] [ 2. 3 I NSULATED STEEL DOOR SYSTEMS
NOTE: I nsul at ed st eel door s and f r ames ar e r ecommended f or ent r ances t o dwel l i ng uni t s i n UEPH' s and bar r acks. Edi t or del et e t he par agr aph t o sui t t he pr oj ect .
SECTI ON 08 11 13 Page 10
Pr ovi de i nsul at ed st eel door s and f r ames i n accor dance wi t h SDI / DOOR 113 at ent r ances t o dwel l i ng uni t s and wher e i ndi cat ed. Meet ener gy r equi r ement s i ncl udi ng Sol ar Heat Gai n Coef f i c i ent ( SHGC) and U- f act or .
Pr ovi de i nsul at ed st eel door s wi t h a cor e of pol yur et hane f oam; f ace sheet s, edges, and f r ames of gal vani zed st eel not l i ght er t han 0. 7 mm t hi ck 23 gage, 1. 5 mm t hi ck 16 gage, and 1. 5 mm 16 gage r espect i vel y; magnet i c weat her st r i ppi ng; nonr emovabl e- pi n hi nges; t her mal - br eak al umi num t hr eshol d; and vi nyl door bot t om. Pr ovi de t o door s and f r ames a phosphat e t r eat ment , r ust - i nhi bi t i ve pr i mer , and baked acr yl i c enamel f i ni sh. Test door s i n accor dance wi t h SDI / DOOR A250. 4 and meet t he r equi r ement s f or Level C. Pr epar e door s t o r ecei ve speci f i ed har dwar e. Pr ovi de door s 44. 5 mm 1- 3/ 4 i nch t hi ck.
] 2. 4 ACCESSORI ES
2. 4. 1 Shel ves f or Dut ch Door s
SDI / DOOR 111. Fabr i cat e shel ves of st eel not l i ght er t han 1. 5 mm t hi ck 16 gage, [ [ _____] mm i nches wi de] [ of t he s i ze i ndi cat ed] . Pr ovi de br acket s of st ock t ype f abr i cat ed of t he same met al used t o f abr i cat e shel ves.
2. 4. 2 Louver s
NOTE: I nt er i or and ext er i or l ouver s ar e appl i ed t o st eel door s di f f er ent l y. I nt er i or door l ouver s ar e r emovabl e on si de by mol di ng f l ange and ext er i or door l ouver f r ames ar e per manent l y wel ded t o t he door and pr ovi ded wi t h r emovabl e bi r d scr een or i nsect scr een.
NOTE: Avoi d l ouver s on ext er i or door s i n humi d l ocat i ons or pr oj ect l ocat i ons wi t h Envi r onment al Sever i t y Cl assi f i cat i ons ( ESC) of C3 t hr u C5 as t hey ar e ver y suscept i bl e t o weat her det er i or at i on.
Humi d l ocat i ons ar e t hose i n ASHRAE cl i mat e zones 0A, 1A, 2A, 3A, 3C, 4C and 5C ( as i dent i f i ed i n ASHRAE 90. 1) . See UFC 1- 200- 01 f or det er mi nat i on of ESC f or pr oj ect l ocat i ons. Consi der ot her means of pr ovi di ng t he vent i ng f unct i on.
Ensur e t hat l ouver s i n door s ar e dr ai nabl e, weat her pr oof and f act or y pr i med. Door s wi t h f act or y- i nst al l ed l ouver s ar e al so r ecommended.
2. 4. 2. 1 I nt er i or Louver s
NOTE: Li ght pr oof l ouver s ar e used when l i ght t r ansmi ssi on must be avoi ded. However , t hese pr ovi de a mi ni mal f r ee ai r f l ow.
SDI / DOOR 111. Wher e i ndi cat ed, pr ovi de l ouver s of st at i onar y [ s i ght pr oof ] [ and ] [ l i ght pr oof ] t ype[ wher e schedul ed] . [ Louver s f or l i ght pr oof must not t r ansmi t l i ght . ] Det achabl e mol di ngs on r oom or non
SECTI ON 08 11 13 Page 11 secur i t y s i de of door ; on secur i t y s i de of door , mol di ngs t o be i nt egr al par t of l ouver . For m l ouver f r ames of 0. 9 mm t hi ck 20 gage st eel and l ouver bl ades of a mi ni mum 0. 6 mm 24 gage. [ Louver s f or l i ght pr oof door s must have mi ni mum of 20 per cent net - f r ee openi ng. ] [ Si ght pr oof l ouver s t o be i nver t ed [ " V" bl ade desi gn wi t h mi ni mum 55] [ and ] [ i nver t ed [ " Y" ] bl ade desi gn wi t h mi ni mum 40] per cent net - f r ee openi ng. ]
2. 4. 2. 2 Ext er i or Louver s
NOTE: Use al umi num scr eens i n humi d l ocat i ons or pr oj ect l ocat i ons wi t h Envi r onment al Sever i t y Cl assi f i cat i ons ( ESC) of C3 t hr u C5. Humi d l ocat i ons ar e t hose i n ASHRAE cl i mat e zones 0A, 1A, 2A, 3A, 3C, 4C and 5C ( as i dent i f i ed i n ASHRAE
90. 1) . See UFC 1- 200- 01 f or det er mi nat i on of ESC f or pr oj ect l ocat i ons.
Pr ovi de l ouver s of t he i nver t ed [ " Y" ] [ " V" ] [ " Z" ] t ype wi t h mi ni mum of [ 30] [ 55] [ 35] per cent net - f r ee openi ng. Wel d or t enon l ouver bl ades t o cont i nuous channel f r ame and wel d assembl y t o door t o f or m wat er t i ght assembl y. For m l ouver s of hot - di p gal vani zed st eel of same gage as door f aci ngs. At l ouver s pr ovi de st eel - f r amed [ i nsect ] [ bi r d] scr eens secur ed t o r oom si de and r eadi l y r emovabl e. Pr ovi de [ al umi num wi r e c l ot h, 7 by 7 per 10 mm or 7 by 6 per 10 mm 18 by 18 or 18 by 16 i nch mesh, f or i nsect scr eens] [ gal vani zed st eel , 13 by 13 mm 1/ 2 by 1/ 2 i nch mesh har dwar e cl ot h, f or bi r d scr eens] . Net - f r ee l ouver ar ea t o be bef or e scr eeni ng.
2. 4. 3 Ast r agal s
For pai r s of ext er i or st eel door s whi ch wi l l not have al umi num ast r agal s or r emovabl e mul l i ons, as speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE pr ovi de over l appi ng st eel ast r agal s wi t h t he door s.
2. 4. 4 Mol di ngs
Pr ovi de mol di ngs ar ound gl ass of i nt er i or and ext er i or door s and l ouver s of i nt er i or door s. Pr ovi de nonr emovabl e mol di ngs on out si de of ext er i or door s and on cor r i dor s i de of i nt er i or door s. Ot her mol di ngs may be st at i onar y or r emovabl e. Secur e i nsi de mol di ngs t o st at i onar y mol di ngs, or pr ovi de snap- on mol di ngs.
2. 5 I NSULATI ON CORES
NOTE: Door manuf act ur er s use var i ous i nsul at i on mat er i al s as t hei r st andar d. Unl ess t he desi gner has a speci f i c r eason t o el i mi nat e an i nsul at i on mat er i al , i t i s advi sed t o mai nt ai n al l l i s t ed t ypes of i nsul at i on mat er i al s.
I f addi t i onal i nt er i or or speci al t y door s r equi r e t her mal i nsul at i on i ncl ude t he br acket ed opt i on and i ndi cat e t hese r equi r ement s on t he door schedul e i n t he dr awi ngs.
Pr ovi de i nsul at i ng cor es at al l ext er i or door s[ and ot her speci f i c door s
SECTI ON 08 11 13 Page 12 not ed i n t he door schedul e] , and pr ovi de an appar ent U- f act or of . 48 i n accor dance wi t h SDI / DOOR 113 and conf or mi ng t o:
a. Ri gi d Cel l ul ar Pol y i socyanur at e Foam: ASTM C591, Type I or I I , f oamed- i n- pl ace or i n boar d f or m, wi t h oxygen i ndex of not l ess t han 22 per cent when t est ed i n accor dance wi t h ASTM D2863; or
b. Ri gi d Pol yst yr ene Foam Boar d: ASTM C578, Type I or I I ; or
c. Mi ner al boar d: ASTM C612, Type I .
2. 6 STANDARD STEEL FRAMES
NOTE: Desi gnat e whet her f r ames ar e t o be wel ded or knock- down f i el d- assembl ed t ype. I n gener al , ut i l i ze wel ded f r ames unl ess knock- down f r ames ar e r equi r ed due t o a r enovat i on pr oj ect or t he t empor ar y nat ur e of t he par t i t i ons bei ng const r uct ed. Wel ded f r ames must be bui l t i n as CMU wal l s ar e const r uct ed or bef or e dr ywal l i s i nst al l ed on st uds. Sl i p- on dr ywal l f r ames must be knock- down t ype t o be i nser t ed af t er dr ywal l i s i nst al l ed.
When bot h t ypes ar e r equi r ed f or t he pr oj ect , modi f y par agr aph t o speci f y bot h t ypes and l ocat i ons wher e r equi r ed.
SDI / DOOR A250. 8, Level [ 1] [ 2] [ 3] [ 4] , except as ot her wi se speci f i ed. For m f r ames t o s i zes and shapes i ndi cat ed, wi t h [ wel ded cor ner s] [ or ] [ knock- down f i el d- assembl ed cor ner s] . Pr ovi de st eel f r ames f or door s, [ t r ansoms, ] [ s i del i ght s, ] [ mul l i ons, ] [ cased openi ngs, ] [ and ] [ i nt er i or gl azed panel s, ] unl ess ot her wi se i ndi cat ed. Pr ovi de f r ame pr oduct t hat uses a mi ni mum of 25 per cent r ecycl ed cont ent . Pr ovi de dat a i ndi cat i ng per cent age of r ecycl ed cont ent f or st eel f r ame pr oduct .
2. 6. 1 Wel ded Fr ames
Cont i nuousl y wel d f r ame f aces at cor ner j oi nt s. Mechani cal l y i nt er l ock or cont i nuousl y wel d st ops and r abbet s. Gr i nd wel ds smoot h.
Wel d f r ames i n accor dance wi t h t he r ecommended pr act i ce of t he St r uct ur al Wel di ng Code Sect i ons 1 t hr ough 6, AWS D1. 1/ D1. 1M and i n accor dance wi t h t he pr act i ce speci f i ed by t he pr oducer of t he met al bei ng wel ded.
[ 2. 6. 2 Knock- Down Fr ames
NOTE: Remove t hi s sect i on unl ess knock- down f r ames ar e r equi r ed due t o a r enovat i on pr oj ect or t he t empor ar y nat ur e of t he par t i t i ons bei ng const r uct ed.
Desi gn cor ner s f or s i mpl e f i el d assembl y by conceal ed t enons, spl i ce pl at es, or i nt er l ocki ng j oi nt s t hat pr oduce squar e, r i gi d cor ner s and a t i ght f i t and mai nt ai n t he al i gnment of adj oi ni ng member s. Pr ovi de l ocknut s f or bol t ed connect i ons.
SECTI ON 08 11 13 Page 13
] 2. 6. 3 Mul l i ons and Tr ansom Bar s
Pr ovi de mul l i ons and t r ansom bar s of c l osed or t ubul ar const r uct i on wi t h heads and j ambs but t - wel ded t oget her [ or knock- down f or f i el d assembl y] .
Bot t om of door mul l i ons must have adj ust abl e f l oor anchor s and spr eader connect i ons.
2. 6. 4 St ops and Beads
Pr ovi de f or m and l oose st ops and beads f r om 0. 9 mm t hi ck 20 gage st eel .
Pr ovi de f or gl azed and ot her openi ngs i n st andar d st eel f r ames. Secur e beads t o f r ames wi t h oval - head, count er sunk Phi l l i ps sel f - t appi ng sheet met al scr ews or conceal ed cl i ps and f ast ener s. Space f ast ener s appr oxi mat el y 300 t o 400 mm 12 t o 16 i nch on cent er . Mi t er mol ded shapes at cor ner s. But t or mi t er squar e or r ect angul ar beads at cor ner s.
2. 6. 5 Ter mi nat ed St ops
NOTE: Speci f y or i ndi cat e when st ops ( r abbet st r i ps) ar e r equi r ed t o be t er mi nat ed above t he f l oor ; gener al l y, t er mi nat ed st ops ar e used i n hospi t al s and si mi l ar bui l di ngs t o el i mi nat e pr oj ect i ons on whi ch wheel s of beds and car t s ar e caught and t o el i mi nat e smal l , di r t - cat chi ng cor ner s.
Wher e i ndi cat ed, t er mi nat e i nt er i or door f r ame st ops 150 mm 6 i nch above f l oor . [ Do not t er mi nat e st ops of f r ames f or [ l i ght pr oof , ] [ soundpr oof , ] [ or l ead- l i ned] door s. ]
2. 6. 6 Cased Openi ngs
Fabr i cat e f r ames f or cased openi ngs of same mat er i al , gage, and assembl y as speci f i ed f or met al door f r ames, except omi t door st ops and pr epar at i on f or har dwar e.
2. 6. 7 Anchor s
Pr ovi de anchor s t o secur e t he f r ame t o adj oi ni ng const r uct i on. Pr ovi de st eel anchor s, z i nc- coat ed not l i ght er t han 1. 2 mm t hi ck 18 gage.
2. 6. 7. 1 Wal l Anchor s
Pr ovi de at l east t hr ee anchor s f or each j amb. For f r ames whi ch ar e mor e t han 2285 mm 7. 5 f eet i n hei ght , pr ovi de one addi t i onal anchor f or each j amb f or each addi t i onal 760 mm 2. 5 f eet or f r act i on t her eof .
a. Masonr y: Pr ovi de anchor s of cor r ugat ed or per f or at ed st eel st r aps or 5 mm 3/ 16 i nch di amet er st eel wi r e, adj ust abl e or T- shaped;
b. St ud par t i t i ons: Wel d or ot her wi se secur el y f ast en anchor s t o backs of f r ames. Desi gn anchor s t o be f ast ened [ t o wood st uds wi t h nai l s, ] [ t o c l osed st eel st uds wi t h sheet met al scr ews, and t o open st eel st uds by wi r i ng or wel di ng] ;
c. Compl et ed openi ngs: Secur e f r ames t o pr evi ousl y pl aced concr et e or masonr y wi t h expansi on bol t s i n accor dance wi t h SDI / DOOR 111;
and
SECTI ON 08 11 13 Page 14
d. Sol i d pl ast er par t i t i ons: Secur e anchor s sol i dl y t o back of f r ames and t i e i nt o t he l at h. Pr ovi de adj ust abl e t op st r ut anchor s on each si de of f r ame f or f ast eni ng t o st r uct ur al member s or cei l i ng const r uct i on above. Pr ovi de si ze and t ype of st r ut anchor s as r ecommended by t he f r ame manuf act ur er .
2. 6. 7. 2 Fl oor Anchor s
NOTE: I n masonr y const r uct i on, ext ensi on cl i ps at bot t om of f r ames ar e usual l y r equi r ed i n l ocat i ons wher e addi t i onal f l oor f i l l occur s on t op of st r uct ur al s l abs, and t he met al f r ames and par t i t i ons ar e i nst al l ed bef or e t he f i l l i s pl aced.
I n such cases, t he dr awi ngs or speci f i cat i ons shoul d i ndi cat e t he di st ance r equi r ed bet ween t he r ough sl ab and f i ni shed f l oor .
Pr ovi de f l oor anchor s dr i l l ed f or 10 mm 3/ 8 i nch anchor bol t s at bot t om of each j amb member . [ Wher e f l oor f i l l occur s, t er mi nat e bot t om of f r ames at t he i ndi cat ed f i ni shed f l oor l evel s and suppor t by adj ust abl e ext ensi on cl i ps r est i ng on and anchor ed t o t he st r uct ur al s l abs. ]
2. 7 FI RE [ AND] [ SMOKE] DOORS AND FRAMES
NOTE: For each openi ng r equi r i ng l abel ed door s, speci f y or i ndi cat e t he hour l y r at i ng of f i r e door s, as est abl i shed by t he Nat i onal Fi r e Pr ot ect i on Associ at i on. When l abel ed door s ar e necessar y on bot h s i des of a f i r e wal l , pr ovi de adequat e det ai l s. Label s cannot be obt ai ned f or doubl e- act i ng door s or f or st eel angl e f r ames.
Met al f r ames t o r ecei ve l abel ed wood f i r e door s must al so be l abel ed.
I f t he f aci l i t y i ncl udes spr i nkl er s and ot her f i r e pr ot ect i on measur es, door s may or may not r equi r e i nsul at i on f or t emper at ur e r i se. I n pr oj ect s t hat r equi r e t emper at ur e r i se cr i t er i a on f i r e door s, i ncl ude t he br acket ed l ast sent ence i n t he par agr aph bel ow and i ndi cat e t hi s r equi r ement i n t he door schedul e.
Pr ovi de f i r e[ and smoke] door s and f r ames i n accor dance wi t h NFPA 80[ and ] [ NFPA 105] and t hi s speci f i cat i on. [ I ncl ude i nsul at ed cor e mat er i al s i n f i r e door s wher e i ndi cat ed i n t he door schedul e. ]
2. 7. 1 Label s
Pr ovi de f i r e door s and f r ames bear i ng t he l abel of Under wr i t er s Labor at or i es ( UL) , Fact or y Mut ual Engi neer i ng and Resear ch ( FM) , or War nock Her sey I nt er nat i onal ( WHI ) at t est i ng t o t he r at i ng r equi r ed.
Test i ng must be i n accor dance wi t h NFPA 252 or UL 10C. Pr ovi de l abel s t hat ar e met al wi t h r ai sed l et t er s, bear i ng t he name or f i l e number of t he door and f r ame manuf act ur er . Label s must be per manent l y af f i xed at t he
SECTI ON 08 11 13 Page 15 f act or y t o f r ames and t o t he hi nge edge of t he door . Do not pai nt door and l abel s.
2. 7. 2 Over si zed Door s
For f i r e door s and f r ames whi ch exceed t he si ze f or whi ch t est i ng and l abel i ng ar e avai l abl e, f ur ni sh cer t i f i cat es st at i ng t hat t he door s and f r ames ar e i dent i cal i n desi gn, mat er i al s, and const r uct i on t o a door whi ch has been t est ed and meet s t he r equi r ement s f or t he c l ass i ndi cat ed.
2. 7. 3 Ast r agal on Fi r e [ and Smoke] Door s
On pai r s of l abel ed f i r e door s, conf or m t o NFPA 80 and UL r equi r ement s. [ On smoke cont r ol door s, conf or m t o NFPA 105. ]
2. 8 EXTERI OR FRAMES
NOTE: I n l i eu of gr out i ng ext er i or f r ames whi ch i s no l onger r ecommended by SDI / Door , t he mi ni mum t hi ckness of ext er i or door f r ames r equi r ed her ei n pr ovi des secur i t y wi t hout gr out i ng t he f r ame.
Pr ovi de t her mal i nsul at i on i n al l ext er i or f r ames. Pr ovi de f r ames of a mi ni mum Level 4, wi t h f r ames of a mi ni mum t hi ckness of 1. 7 mm 0. 067 i nch, 14 gage.
2. 9 HARDWARE PREPARATI ON
Dr i l l and t ap door s and f r ames t o r ecei ve f i ni sh har dwar e. Pr epar e door s and f r ames f or har dwar e i n accor dance wi t h t he appl i cabl e r equi r ement s of SDI / DOOR A250. 8 and SDI / DOOR A250. 6. For addi t i onal r equi r ement s r ef er t o ANSI / BHMA A156. 115. Dr i l l and t ap f or sur f ace- appl i ed har dwar e at t he pr oj ect s i t e. Bui l d addi t i onal r ei nf or ci ng f or sur f ace- appl i ed har dwar e i nt o t he door at t he f act or y. Punch door f r ames[ , wi t h t he except i on of f r ames t hat wi l l have weat her st r i ppi ng [ or ] [ l i ght pr oof ] [ or ] [ soundpr oof ] gasket i ng, ] t o r ecei ve a mi ni mum of t wo r ubber or v i nyl door s i l encer s on l ock s i de of s i ngl e door s and one si l encer f or each l eaf at heads of doubl e door s. Set l ock st r i kes out t o pr ovi de cl ear ance f or s i l encer s.
2. 10 FI NI SHES
NOTE: Speci f y t he t ype f i ni sh r equi r ed f or t he t ype of st eel used f or f abr i cat i on of door s and f r ames.
Speci f y hot - di p z i nc- coat ed st eel f or ext er i or hol l ow met al door s and f r ames i n humi d l ocat i ons or pr oj ect l ocat i ons wi t h Envi r onment al Sever i t y Cl assi f i cat i ons ( ESC) of C3 t hr u C5. Al so speci f y hot - di p z i nc- coat ed st eel f or i nt er i or hol l ow met al door s and f r ames i n hi gh humi di t y bui l di ng spaces and i nt er i or door s at pr oj ect l ocat i ons wi t h ESC cl assi f i cat i ons of C4 and C5. Hugh humi di t y bui l di ng spaces i ncl ude bat hr ooms, l ocker r ooms, shower ar eas, l aundr y r ooms, pool s, and t r ai ner s.
Humi d l ocat i ons ar e t hose i n ASHRAE cl i mat e zones 0A, 1A, 2A, 3A, 3C, 4C and 5C ( as i dent i f i ed i n ASHRAE 90. 1) . See UFC 1- 200- 01 f or det er mi nat i on of
SECTI ON 08 11 13 Page 16
ESC f or pr oj ect l ocat i ons. Gal vanneal ed st eel i s sui t abl e f or i nt er i or door s and f r ames i n most bui l di ngs i n ESC l ocat i ons of C1 and C2. Unl ess f act or y f i ni sh coat i ng i s r equi r ed, speci f y f i ni sh coat i ng wi l l be appl i ed by f i el d pai nt i ng i n Sect i on
09 90 00 PAI NTS AND COATI NGS.
[ 2. 10. 1 Fact or y- Pr i med Fi ni sh
Thor oughl y c l ean al l sur f aces of door s and f r ames t hen chemi cal l y t r eat and f act or y pr i me wi t h a r ust i nhi bi t i ng coat i ng as speci f i ed i n SDI / DOOR A250. 8[ . ] [ , or pai nt abl e A25 gal vanneal ed st eel wi t hout pr i mer .
Wher e coat i ng i s r emoved by wel di ng, appl y t ouchup of f act or y pr i mer . ]
] [ 2. 10. 2 Hot - Di p Zi nc- Coat ed and Fact or y- Pr i med Fi ni sh
Fabr i cat e [ ext er i or ] [ i nt er i or ] [ schedul ed] door s and f r ames f r om hot di pped zi nc coat ed st eel , al l oyed t ype, t hat compl i es wi t h ASTM A924/ A924M and ASTM A653/ A653M. The coat i ng wei ght must meet or exceed t he mi ni mum r equi r ement s f or coat i ngs havi ng 122 gr ams per squar e met er 0. 4 ounces per squar e f oot , t ot al bot h s i des, i . e. , ZF120 A40. Repai r damaged zi nc- coat ed sur f aces by t he appl i cat i on of z i nc dust pai nt . Thor oughl y c l ean and chemi cal l y t r eat t o i nsur e maxi mum pai nt adhesi on. Fact or y pr i me as speci f i ed i n SDI / DOOR A250. 8. [ Pr ovi de f or [ ext er i or door s] [ and ] [ i nt er i or door s] [ door openi ngs No. [ _____] ] ] .
] 2. 10. 3 El ect r ol yt i c Zi nc- Coat ed Anchor s and Accessor i es
Pr ovi de el ect r ol yt i cal l y deposi t ed z i nc- coat ed st eel i n accor dance wi t h ASTM A879/ A879M, Commer ci al Qual i t y, Coat i ng Cl ass A. Phosphat e t r eat and f act or y pr i me zi nc- coat ed sur f aces as speci f i ed i n SDI / DOOR A250. 8.
[ 2. 10. 4 Fact or y- Appl i ed Enamel Fi ni sh
NOTE: Use t hi s par agr aph i f f i el d coat i ngs as speci f i ed i n Sect i on 09 90 00 PAI NTS AND COATI NGS ar e not r equi r ed or pr ovi ded. One coat of f act or y- appl i ed enamel f i ni sh i s r eadi l y avai l abl e i n st andar d col or s. Two coat s and speci al col or s add t o cost and t o del i ver y t i me.
Pr ovi de coat i ngs t hat meet t est pr ocedur es and accept ance cr i t er i a i n accor dance wi t h SDI / DOOR A250. 3. Af t er f act or y pr i mi ng, appl y [ one coat ] [ t wo coat s] of [ l ow- gl oss] [ medi um- gl oss] enamel t o exposed sur f aces.
Separ at el y bake or oven dr y each coat . Dr yi ng t i me and t emper at ur e r equi r ement s must be i n accor dance wi t h t he coat i ng manuf act ur er ' s r ecommendat i ons. Pr ovi de f i ni sh coat col or ( s) [ as i ndi cat ed] [ _____] t o mat ch appr oved col or sampl e( s) .
] 2. 11 FABRI CATI ON AND WORKMANSHI P
Pr ovi de f i ni shed door s and f r ames t hat ar e st r ong and r i gi d, neat i n appear ance, and f r ee f r om def ect s, waves, scr at ches, cut s, dent s, r i dges, hol es, war p, and buckl e. Pr ovi de mol ded member s t hat ar e c l ean cut , st r ai ght , and t r ue, wi t h j oi nt s coped or mi t er ed, wel l f or med, and i n t r ue al i gnment . Dr ess exposed wel ded and sol der ed j oi nt s smoot h. Desi gn door
SECTI ON 08 11 13 Page 17 f r ame sect i ons f or use wi t h t he wal l const r uct i on i ndi cat ed. Cor ner j oi nt s must be wel l f or med and i n t r ue al i gnment . Conceal f ast eni ngs wher e pr act i cabl e. [ Fr ames f or use i n sol i d pl ast er par t i t i ons must be wel ded const r uct i on. ] [ On wr apar ound f r ames f or masonr y par t i t i ons, pr ovi de a t hr oat openi ng 3 mm 1/ 8 i nch l ar ger t han t he act ual masonr y t hi ckness. ] [ Desi gn[ ot her ] f r ames i n exposed masonr y wal l s or par t i t i ons t o al l ow suf f i c i ent space bet ween t he i nsi de back of t r i m and masonr y t o r ecei ve caul k i ng compound. ]
2. 12 PROVI SI ONS FOR GLAZI NG
Mat er i al s ar e speci f i ed i n Sect i on 08 81 00, GLAZI NG.
PART 3 EXECUTI ON
3. 1 I NSTALLATI ON
3. 1. 1 Fr ames
Set f r ames i n accor dance wi t h SDI / DOOR A250. 11. Pl umb, al i gn, and br ace secur el y unt i l per manent anchor s ar e set . Anchor bot t oms of f r ames wi t h expansi on bol t s or powder - act uat ed f ast ener s. Bui l d i n or secur e wal l anchor s t o adj oi ni ng const r uct i on. [ Wher e f r ames r equi r e cei l i ng st r ut s or over head br aci ng, anchor f r ames t o t he st r ut s or br aci ng. ]
3. 1. 2 Door s
Hang door s i n accor dance wi t h c l ear ances speci f i ed i n SDI / DOOR A250. 8.
Af t er er ect i on and gl azi ng, c l ean and adj ust har dwar e.
3. 1. 3 Fi r e [ and Smoke] Door s and Fr ames
I nst al l f i r e door s and f r ames, i ncl udi ng har dwar e, i n accor dance wi t h NFPA 80. [ I nst al l [ f i r e r at ed] smoke door s and f r ames i n accor dance wi t h [ NFPA 80] [ and ] [ NFPA 105] . ]
3. 2 PROTECTI ON
Pr ot ect door s and f r ames f r om damage. Repai r damaged door s and f r ames pr i or t o compl et i on and accept ance of t he pr oj ect or r epl ace wi t h new, as di r ect ed. Wi r e br ush r ust ed f r ames unt i l r ust i s r emoved. Cl ean t hor oughl y. Appl y an al l - over coat of r ust - i nhi bi t i ve pai nt of t he same t ype used f or shop coat .
3. 3 CLEANI NG
Upon compl et i on, c l ean exposed sur f aces of door s and f r ames t hor oughl y.
Remove mast i c smear s and ot her unsi ght l y mar ks.
- - End of Sect i on - -