ATTACHMENT 2 - NLZG242002 B885 3D Printer Setup A-101 UPDATE.pdf
PDF 193 KB Posted
- Attached to
- 3d Printer Room Upgrade Federal contract opportunity
- Solicitation number
- W50S8P24B0001
- Issued by
- Department of the Army National Guard
About this file
This document consists of a solicitation for a 3D printer room upgrade project at Rickenbacker Air Base in Columbus, Ohio. The project involves required modifications to Facility Room 112 to accommodate a new 3D printer unit, including installing a new 50-amp power supply and additional overhead lighting. A new double-door access will also be cut into an exterior wall. The project magnitude is estimated between $25,000 to $100,000. The solicitation will be a competitive small business set-aside awarded to the responsible bidder offering the most advantageous price. The contractor must run the new power and cut the door opening within approximately 35 days of award, which is expected 120 days after solicitation issuance. The Department of the Army National Guard is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Office
Fabrication
Supervisor
Structures Office
Jet Shop Office
Jet Shop Admin
Corridor
Fabrication Admin
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
I T
T E
D
B
Y
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
C O
N T
R A
C T
N
O
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
S I Z
E
M A
R K
D E
S C
R I P
T I O
N D
A T
E
SHEET ID
S
T
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S
T
A
I R
E F
U E
L I N
G
W
I N
G
R I C
K E
N B
A C
K E
R
A
A T
I O
N A
L
G
U A
D
B
S
E
M
I N
U T
E M
W
Y
C
L U
M B
U S
O
H
A N
S I
D
R I C
K E
N B
A C
K E
R
A
T
I O
N A
L
G
U A
B
S
E
O
H I O
N L Z
G
B
L D
G
P
I N
T E
R
I N
S T
A L L
B U
I L D
I N
G
M
H
I S
S O
M
S
P
R I C
E
M
H
I S
S O
M
S
P
R I C
E
F L O
P
L A
N
M
U L T
I D
I S
C I P
L I N
E
A-101
A
T
I O
N A
L
G
U A
R D
..\..\..\..\32-22-(BCE) Map Drawings\ACAD\2020_AutoCAD 2D Files\Templates\1Best ANG.jpg
SCALE: 1/4" = 1'-0 '
MULTIDISCIPLINE FLOOR PLAN
B1
PLAN
NORTH
1. VERIFY EXISTING CONDITIONS. COORDINATE THE EXTENT OF DEMOLITION
WORK AND EXISTING WORK TO REMAIN, WITH NEW WORK.
2. EXISTING FLOOR PLANS ARE BASED ON COPIES OF ARCHIVE DRAWINGS
PROVIDED BY THE GOVERNMENT. ACTUAL EXISTING WALL LOCATION/
ASSEMBLY MAY VARY. REPORT DISCREPANCIES, CONFLICTS OR
UNEXPECTED CONDITIONS TO THE CONTRACTING OFFICER.
3. REPAIR / PATCH NEW OPENINGS IN WALLS, PARTITIONS, FLOORS AND
CEILINGS WHERE DEMOLITION OCCURS. MATCH EXISTING ADJACENT
SURFACE FINISHES.
4. FIRE SEAL ANY PENETRATIONS IN FIRE RATED WALLS. FIRE RATED WALLS
ARE MARKED ON DRAWING SET.
5. IN-SERVICE EQUIPMENT SHALL BE PROTECTED FROM CONSTRUCTION
ACTIVITIES AT ALL TIMES.
6. MAINTAIN AN UNOBSTRUCTED EXIT PATH TO THE PRIMARY EXITS FOR THE
DURATION OF CONSTRUCTION.
7. WORK AREA SHALL BE KEPT CLEAN OF DEBRIS AND DUST AT THE END OF
EACH WORK DAY.
GENERAL ARCHITECTUAL NOTES
ARCHITECTURAL KEYNOTES
1. EXISTING PANEL PT-101 TO BE USED FOR NEW 240V 50A SERVICE.
2. DEMOLITION EXISTING CMU, REMOVE ELECTRICAL, INSTALL DOUBLE FRAME
DOOR, DOOR OPENING 72" WIDE X 88" HEIGHT. INSTALL LINTEL IN NEW
OPENING FOR DOOR FRAME (6 X 3.5 X
3. PROPOSED CONDUIT RUN OF 240V 50A SERVICE FROM PT-101 PANEL TO
ROOM 112. BEST FIT NEW CONDUIT RUN TO EXISTING CONDUIT RUNS IN
ROOM, PAINT TO MATCH WALL AND EXISTING CONDUIT. CONDUIT RUNS ARE
APPROXIMATELY 63' TO ROOM 112 X 12' ACROSS ROOM 112 X 8.5' DOWN THE
WALL OF ROOM 112.
4. NEW LIGHT FIXTURE TO MATCH EXISTING FIXTURE. SEE SOW FOR MODEL
AND SPECIFICATION. LIGHTS TO BE APPROXIMATELY 44" ON CENTER AWAY
FROM WALLS AND 96" FROM NEWLY PLACED DOUBLE DOOR WALL.
SCALE: 1/4" = 1'-0 '
ELECTRICAL PANEL LOCATION
J1
0 2' 4'1'
0 2' 4'1'