This document is an architectural drawing set for existing conditions of Buildings 45-47 at the Missouri Army National Guard's Jefferson Barracks facility. It includes elevations, window/door schedules, and notes related to a historical rehabilitation project.

The related federal contract opportunity is for the demolition of Buildings 45-47 at the same facility. The solicitation (W50S8K24QA001) seeks quotations for carefully demolishing the buildings so that materials can be salvaged and reused. A pre-quote site visit is scheduled for July 30, 2024. The work is being procured by the Department of the Army Missouri Army National Guard.

View the file

Other files

File Type Posted
W50S8K24QA001001 Amend 1.pdf PDF
B4 WD General Decision MO20240089 Mod 6 20240809.pdf PDF
A2 PWS_LTUY212003 Demo BCE Facs 45-47_20240813.pdf PDF
RFI 2 - 047-Arch-1st-Elev-Plot.pdf PDF
RFI 2 - 045-046-047-Roof-Plot.pdf PDF
B6 RFI_LTUY212003 Demo B45-47.xlsx XLSX spreadsheet
RFI 2 - 045-046-047-Site-Plot.pdf PDF
RFI 2 - 045-Arch-1st-Elev-Plot.pdf PDF
B7 20240730 Pre-Quote Site Visit Sign-In.pdf PDF
B7 20240730 Pre-Quote Site Visit Minutes_signed.pdf PDF
B6 Excerpt - Base Lead-Based Paint Mgmt Plan.pdf PDF
B6 19911021_EnvSamplingAnalysis_B47.pdf PDF
B6 Excerpt - Base Asbestos Mgmt Plan.pdf PDF
Bldg 45 - North - West Sides.jpg JPG image
Bldg 46 - South - West Sides.jpg JPG image
North View - All Buildings.pdf PDF
Bldg 47 - North - West Sides.jpg JPG image
Bldg 47 - South - East Sides.jpg JPG image
Bldg 45 - North - East Sides.jpg JPG image
Bldg 46 - North Side.jpg JPG image
Bldg 46 - South - East Sides.jpg JPG image
Bldg 45 - South - West Sides.jpg JPG image
Bldg 45 - South - East Sides.jpg JPG image
Bldg 47 - North - East Sides.jpg JPG image
Bldg 47 - West Side.jpg JPG image
B4 WD General Decision MO20240089 Mod 4 20240705.pdf PDF
A2 PWS_LTUY212003 Demo BCE Facs 45-47_20240426.pdf PDF
Solicitation - W50S8K24QA001.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Graphic Scale: 1/16"=1'-0"

0 16' 32' 48' 64'

046-ARCH-1ST-ELEV

SCALE: 1/16"=1'-0"

M K

R

EV

IS

IO

N D

AT

E

D R

AW

N

C H

EC

KE

D

SC

AL

E

C

AT

EG

O

R Y

C O

D E

D

AT

E

D R

AW

IN

G N

O

AP

PR

O

VE

D B

Y

C H

EC

KE

D B

Y

D R

AW

N

B Y

SH

EE

T O

F

AI

R

NA

TI

ON

AL

GU

AR

D

CI

VI

L

E N G

IN

E

ER

IN

G

GEO

GRA

PH

IAE

S C

I EN

TIA

EQ

UE

CO

NF

IN

IA

PE

NE

TR

AM

US

NORTH

34'-1"

SIDEWALK

TO REMAIN3 SF

* SEE SHEET A4 FOR DETAILS

WEST ELEVATION BUILDING 46

SCALE: 1/16"=1'-0"

(EXISTING CONDITIONS)

GENERAL NOTES

KEYED NOTES

A. WORK ASSOCIATED WITH THE ELEVATED PORCHES, INCLUDING ROOFS,

A

A

4'

-4

B

A

A

A

A

B

A

A

A

A

A

B

A

A

B

A

A

A

A

A

A

B

A

A

A

A

A

B

A

A

B

A

A A

DA

A

A

A

A

A

A

B

A D A

'-8

'-0

'-0

'-0

'-8

18'

3'-2" 5'-0"

5'-0" 6'-4"

2'-10" 3'-2"

6- 8"

T O

'-2

6' -8

" T O

'-2

'-1

" T O

2'

-2 1 2"

8' -6

'-1

" T O

2'

-2 1 2"

8' -6

3'-2"

3'-2"

3'-2"

3'-2" 3'-2"

2' -4

3'

-1

'-3

" T O

0'

-5

/2

7' -6

7' -6

'-3

" T O

0'

-5

/2

7' -6

2' -4

3'

-1

A D A ADA

CONCRETE DECK, AND BRICK REMOVAL AND REPLACEMENT ADJACENT TO THE

CONCRETE FLOOR DECK, IS NOT IN THIS CONTRACT. THIS SCOPE OF WORK

INCLUDES ONLY THE CLEANING AND REPOINTING OF BRICK OR AS

OTHERWISE INDICATED IN THESE DOCUMENTS.

A A A A A A A A A A A A A A A A A A A B B B B

E E E E E E E E E E E E

3 4

A A A A A A A A A A A A A A A B B B B

E E1 E1 E1 E1 E1 E1 E1 E1 E

A 1 2 1

1 2 3 4

A B D E E1

3 4

6 4

REMOVE GOOSENECK CONDUIT

REMOVE ELEC. RACK

REMOVE VINES

COAL

CHUTE

TUCKPOINT

LIMESTONE

(TYP.)

T/EXPOSED MASONRY

ELEV. 14'-0"

EXISTING FIN. FLOOR

ELEV.- 0'-0"

EXIST.BASEMENT FLOOR

ELEV.- 9'-0"

ELEV. 14'-0"

T/EXPOSED MASONRY

EXISTING FIN. FLOOR

ELEV. 0'-0"

GROUND WIRE

RESET ARCH

DS

5 SF

20 SF

5 SF

DS

DS

10 SF

DS

2 SF

GROUND WIRE

LINE OF AREA

WELL WALL

DS

15 SF

5 SF

2 SF

1 SF

"L"

5 SF 10 SF

5 SF

DS

5 SF

3 SF 20 SF

REMOVE GOOSENECK

CONDUIT

F.H.

NEW AREA DRAIN (2)

6" PVC

PORCH & STAIRS

NOT IN CONTRACT

AREA WELL WALL

(TO REMAIN)

P.P.

GUY

TRUE NORTH

INSULATING

GLASS (TYP.) FIXED CASEMENT

TRANSOMS (TYP.)

RAISED WOOD PANEL

INSULATING GLASS (TYP.) EXISTING DECORATIVE

WOOD BLOCKING

EXISTING

STONE SILL

DOUBLE HUNG (TYP.)

QUALITY OF DAMAGED, MISSING OR

SPALLED BRICK UNITS.

BASEMENT

HOPPERS (TYP.)

EAST ELEVATION BUILDING 46

SCALE: 1/16"=1'-0"

(EXISTING CONDITIONS)

SOUTH ELEVATION

SCALE: 1/16"=1'-0"

NORTH ELEVATION

SCALE: 1/16"=1'-0"

WINDOW TYPES

SCALE: 1/4"=1'-0"

DOORS TYPES

SCALE: 1/4"=1'-0"

B. THIS IS A HISTORICAL REHABILITION PROJECT. IT IS THE INTENT

TO IDENTIFY, RETAIN AND PRESERVE THE PROFILE AND STYLE OF EXISTING

MATERIALS. THE INTENT IS TO MATCH AS CLOSE AS POSSIBLE NEW MATERIALS

WITH EXISTING MATERIALS IN FORM AND DETAIL WHERE INDICATED. REFER TO

BUILDINGS 45,46 AND 47 EXISTING CONDITIONS.

C. ALL NEW WORK TO MEET THE REQUIREMENTS OF DEPARTMENT OF INTERIORS

STANDARDS FOR REHABILITATION OF REGISTERED NATIONAL HISTORIC BUILDINGS.

E. PROJECT ADJACENT WOOD TRIM, SOFFIT AND GUTTER AND DOWNSPOT AND

GROUNDING WIRE NOT IN CONTRACT FROM DAMAGE DURING CONSTRUCTION.

IF REMOVAL OF WALL ATTACHMENTS IS REQUIRED TO PERFORM THE WORK,

THE ATTACHMENT SHALL BE RESTORED TO ITS ORIGINAL SECURE

CONDITON. DAMAGED SURFACES SHALL BE REPAIRED TO THEIR ORIGINAL

F. CHIMNEYS ABOVE THE ROOF LINE ARE NOT WITHIN THE SCOPE OF WORK

G. REMOVE ALL MISCELLANEOUS ANCHORS AND ATTACHMENTS FROM EXTERIOR OF

BRICK WALLS PRIOR TO TUCKPOINTING.

H. WINDOW SASH AND DOORS TO BE REMOVED. WINDOW AND DOOR FRAMES

ABOVE GRADE TO REMAIN. DOOR FRAMES BELOW GRADE TO BE REPLACED.

EXISTING EXTERIOR WOOD DOOR AND WINDOW HEAD TRIM SHALL BE

RETAINED AND RE-USED TO THE GREATEST EXTENT POSSIBLE. ALL

EXPOSED WOOD SURFACES CONTAIN LEAD-BASE PAINT. SEE

SPECIFICATIONS. EXISTING STEEL RAILINGS CONATAIN LEAD-BASE PAINT.

D. ALL EXPOSED BRICK EXTERIOR WALLS SHALL BE CLEANED, JOINTS RACKED

AND REPOINTED. DAMAGED, MISSING OR SPALLED BRICK UNITS AS

INDICATED SHALL BE REPLACED PRIOR TO POINTING. SEE

SPECIFICATIONS FOR MASONRY RECTORATION AND UNIT PRICING FOR

ADDITIONAL BRICK REPLACEMENT.

CONDITON AT CONTRACTOR'S EXPENSE.

I. VERIFY ALL OPENING DIMENSIONS PRIOR TO WINDOW, DOOR AND DOOR

FRAME FABRICATION. DIMENSIONS GIVEN ARE APPROXIMATE.

J. JOINTS BETWEEN DISSIMILAR MATERIALS INCLUDING HORIZONTAL JOINTS

BETWEEN CONCRETE AND FOUNDATION WALL SHALL BE CAULKED.

K. PAINT OR STAIN EXPOSED WOOD SURFACE SURFACES WHICH ARE NOT

PREFINISHED. PAINT METAL SURFACES. SEE SPECIFICATIONS.

L. REMOVE LEAVES & DEBRIS FROM UNDER PORCHES.

M. ALL BASEMENT DOORS TO SWING AS EXISTING.

REMOVE CONCRETE STAIRS, RETAINING WALL AND FLOOR SLAB

REMOVE FLOOR DRAIN AND CAP LINE OUTSIDE OF WALL.

STEEL HANDRAILS AND ANCHORAGE TO BE COMPLETELY REMOVED.

REMOVE AND REPLACE DOOR AND FRAME.

TUCKPOINT LIMESTONE WHERE INDICATED. MATCH EXISTING MORTAR

COMPOSITION AND EXISTING JOINT TOOLING.

PATCH VERTICAL & HORIZONTAL CONCRETE SURFACES AS INDICATED

REMOVE LOOSE OR DETERIORATED CONCRETE TOPPING AT CURB

REPAIR VERTICAL AND HORIZONTAL SURFACES WITH MASONRY

PATCHING COMPOUND. SEE SPECIFICATIONS.

CONCRETE STAIRS, AREA WELL AND RETAINING WALL. SEE

DETAIL SHEET S1 (NEW).

PROVIDE STEEL GUARDRAILS AND HANDRAILS AT STAIRWELLS, AS

INDICATED. PROVIDED WALL MOUNTED HANDRAIL @ STAIR.

PROVIDE STEEL CLOSURE ON COAL CHUTE DOOR (PAINT). SEE

DETAIL SHEET S1.

LEGEND

PLAN @ BUILDING 45

SCALE: 1/16"=1'-0"PORCH LEVEL

SEE ELEVATIONS FOR

DOORS & WINDOWS IN BSM'T.

ALL SIZES TO BE VERIFIED BY FIELD MEASUREMENT

DOORS TO 7'-6"H - 3 BUTTS PER LEAF

DOORS 7'-6"H TO 9'-0" - 4 BUTTS PER LEAF

DOOR

NUMBER

DOOR SIZE

W x H x T

DOOR

TYPE

FRAME

TYPE QTY

FRAME

TYPE

FRAME DETAILS

HEAD JAMB SILL

HDWRE

GROUP REMARKS

DOOR SCHEDULE

SEE DOOR TYPES ABOVE

SEE DOOR TYPES ABOVE

SEE DOOR TYPES ABOVE

SEE DOOR TYPES ABOVE

WD WD

WD WD

WD WD

WD WD

MATCH

EXISTING

MATCH

EXISTING

MATCH

EXISTING

MATCH

EXISTING

9, 10

9, 10

WINDOW

ID

WINDOW SIZE

W x H x T

WINDOW TYPE

FRAME DETAILS

HEAD SILL

REMARKS

WINDOW SCHEDULE

A

B

C

D

SEE ABOVE DOUBLE HUNG

2,3

JAMB

E

E1

SEE ABOVE

SEE ABOVE

SEE ABOVE

SEE ABOVE

SEE ABOVE

DOUBLE HUNG

DOUBLE HUNG

DOUBLE HUNG

CASEMENT

CASEMENT

2,3

QTY.

5,6

WINDOW FRAMES TO REMAIN

WINDOW FRAMES TO REMAIN

WINDOW FRAMES TO REMAIN

WINDOW FRAMES TO REMAIN

WINDOW FRAME TO BE REMOVED

1" O.D. BARS (6 PER WINDOW)

WINDOW FRAME TO BE REMOVED

1" O.D. BARS (6 PER WINDOW)

9, 10

9, 10

Sc an ne d by S an ch ez

A ss oc ia te s, In c.

T el

: 3

-5

-7

Fa x:

-5

-3

- s an ch ez js an ch ez .c om w w w .js an ch ez .c om Fi le na m e:

D :\J ob s\

6-

Ar ch

-1 st

-E le v.

dw g D at e:

0/

/2

T im e:

8:

8/ 6/

1:

:0

AM

, P lo tte d by : J

. M

AT

TH

EW

S

AutoCAD SHX Text Missouri Air National Guard

AutoCAD SHX Text Jefferson Barracks NGB

AutoCAD SHX Text St. Louis, Missouri 63125

Sheets and Views
Plot
PSALL