RFI 2 - 046-Arch-1st-Elev-Plot.pdf
PDF 233 KB Posted
- Solicitation number
- W50S8K24QA001
About this file
This document is an architectural drawing set for existing conditions of Buildings 45-47 at the Missouri Army National Guard's Jefferson Barracks facility. It includes elevations, window/door schedules, and notes related to a historical rehabilitation project.
The related federal contract opportunity is for the demolition of Buildings 45-47 at the same facility. The solicitation (W50S8K24QA001) seeks quotations for carefully demolishing the buildings so that materials can be salvaged and reused. A pre-quote site visit is scheduled for July 30, 2024. The work is being procured by the Department of the Army Missouri Army National Guard.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Graphic Scale: 1/16"=1'-0"
0 16' 32' 48' 64'
046-ARCH-1ST-ELEV
SCALE: 1/16"=1'-0"
M K
R
EV
IS
IO
N D
AT
E
D R
AW
N
C H
EC
KE
D
SC
AL
E
C
AT
EG
O
R Y
C O
D E
D
AT
E
D R
AW
IN
G N
O
AP
PR
O
VE
D B
Y
C H
EC
KE
D B
Y
D R
AW
N
B Y
SH
EE
T O
F
AI
R
NA
TI
ON
AL
GU
AR
D
CI
VI
L
E N G
IN
E
ER
IN
G
GEO
GRA
PH
IAE
S C
I EN
TIA
EQ
UE
CO
NF
IN
IA
PE
NE
TR
AM
US
NORTH
34'-1"
SIDEWALK
TO REMAIN3 SF
* SEE SHEET A4 FOR DETAILS
WEST ELEVATION BUILDING 46
SCALE: 1/16"=1'-0"
(EXISTING CONDITIONS)
GENERAL NOTES
KEYED NOTES
A. WORK ASSOCIATED WITH THE ELEVATED PORCHES, INCLUDING ROOFS,
A
A
4'
-4
B
A
A
A
A
B
A
A
A
A
A
B
A
A
B
A
A
A
A
A
A
B
A
A
A
A
A
B
A
A
B
A
A A
DA
A
A
A
A
A
A
B
A D A
'-8
'-0
'-0
'-0
'-8
18'
3'-2" 5'-0"
5'-0" 6'-4"
2'-10" 3'-2"
6- 8"
T O
'-2
6' -8
" T O
'-2
'-1
" T O
2'
-2 1 2"
8' -6
'-1
" T O
2'
-2 1 2"
8' -6
3'-2"
3'-2"
3'-2"
3'-2" 3'-2"
2' -4
3'
-1
'-3
" T O
0'
-5
/2
7' -6
7' -6
'-3
" T O
0'
-5
/2
7' -6
2' -4
3'
-1
A D A ADA
CONCRETE DECK, AND BRICK REMOVAL AND REPLACEMENT ADJACENT TO THE
CONCRETE FLOOR DECK, IS NOT IN THIS CONTRACT. THIS SCOPE OF WORK
INCLUDES ONLY THE CLEANING AND REPOINTING OF BRICK OR AS
OTHERWISE INDICATED IN THESE DOCUMENTS.
A A A A A A A A A A A A A A A A A A A B B B B
E E E E E E E E E E E E
3 4
A A A A A A A A A A A A A A A B B B B
E E1 E1 E1 E1 E1 E1 E1 E1 E
A 1 2 1
1 2 3 4
A B D E E1
3 4
6 4
REMOVE GOOSENECK CONDUIT
REMOVE ELEC. RACK
REMOVE VINES
COAL
CHUTE
TUCKPOINT
LIMESTONE
(TYP.)
T/EXPOSED MASONRY
ELEV. 14'-0"
EXISTING FIN. FLOOR
ELEV.- 0'-0"
EXIST.BASEMENT FLOOR
ELEV.- 9'-0"
ELEV. 14'-0"
T/EXPOSED MASONRY
EXISTING FIN. FLOOR
ELEV. 0'-0"
GROUND WIRE
RESET ARCH
DS
5 SF
20 SF
5 SF
DS
DS
10 SF
DS
2 SF
GROUND WIRE
LINE OF AREA
WELL WALL
DS
15 SF
5 SF
2 SF
1 SF
"L"
5 SF 10 SF
5 SF
DS
5 SF
3 SF 20 SF
REMOVE GOOSENECK
CONDUIT
F.H.
NEW AREA DRAIN (2)
6" PVC
PORCH & STAIRS
NOT IN CONTRACT
AREA WELL WALL
(TO REMAIN)
P.P.
GUY
TRUE NORTH
INSULATING
GLASS (TYP.) FIXED CASEMENT
TRANSOMS (TYP.)
RAISED WOOD PANEL
INSULATING GLASS (TYP.) EXISTING DECORATIVE
WOOD BLOCKING
EXISTING
STONE SILL
DOUBLE HUNG (TYP.)
QUALITY OF DAMAGED, MISSING OR
SPALLED BRICK UNITS.
BASEMENT
HOPPERS (TYP.)
EAST ELEVATION BUILDING 46
SCALE: 1/16"=1'-0"
(EXISTING CONDITIONS)
SOUTH ELEVATION
SCALE: 1/16"=1'-0"
NORTH ELEVATION
SCALE: 1/16"=1'-0"
WINDOW TYPES
SCALE: 1/4"=1'-0"
DOORS TYPES
SCALE: 1/4"=1'-0"
B. THIS IS A HISTORICAL REHABILITION PROJECT. IT IS THE INTENT
TO IDENTIFY, RETAIN AND PRESERVE THE PROFILE AND STYLE OF EXISTING
MATERIALS. THE INTENT IS TO MATCH AS CLOSE AS POSSIBLE NEW MATERIALS
WITH EXISTING MATERIALS IN FORM AND DETAIL WHERE INDICATED. REFER TO
BUILDINGS 45,46 AND 47 EXISTING CONDITIONS.
C. ALL NEW WORK TO MEET THE REQUIREMENTS OF DEPARTMENT OF INTERIORS
STANDARDS FOR REHABILITATION OF REGISTERED NATIONAL HISTORIC BUILDINGS.
E. PROJECT ADJACENT WOOD TRIM, SOFFIT AND GUTTER AND DOWNSPOT AND
GROUNDING WIRE NOT IN CONTRACT FROM DAMAGE DURING CONSTRUCTION.
IF REMOVAL OF WALL ATTACHMENTS IS REQUIRED TO PERFORM THE WORK,
THE ATTACHMENT SHALL BE RESTORED TO ITS ORIGINAL SECURE
CONDITON. DAMAGED SURFACES SHALL BE REPAIRED TO THEIR ORIGINAL
F. CHIMNEYS ABOVE THE ROOF LINE ARE NOT WITHIN THE SCOPE OF WORK
G. REMOVE ALL MISCELLANEOUS ANCHORS AND ATTACHMENTS FROM EXTERIOR OF
BRICK WALLS PRIOR TO TUCKPOINTING.
H. WINDOW SASH AND DOORS TO BE REMOVED. WINDOW AND DOOR FRAMES
ABOVE GRADE TO REMAIN. DOOR FRAMES BELOW GRADE TO BE REPLACED.
EXISTING EXTERIOR WOOD DOOR AND WINDOW HEAD TRIM SHALL BE
RETAINED AND RE-USED TO THE GREATEST EXTENT POSSIBLE. ALL
EXPOSED WOOD SURFACES CONTAIN LEAD-BASE PAINT. SEE
SPECIFICATIONS. EXISTING STEEL RAILINGS CONATAIN LEAD-BASE PAINT.
D. ALL EXPOSED BRICK EXTERIOR WALLS SHALL BE CLEANED, JOINTS RACKED
AND REPOINTED. DAMAGED, MISSING OR SPALLED BRICK UNITS AS
INDICATED SHALL BE REPLACED PRIOR TO POINTING. SEE
SPECIFICATIONS FOR MASONRY RECTORATION AND UNIT PRICING FOR
ADDITIONAL BRICK REPLACEMENT.
CONDITON AT CONTRACTOR'S EXPENSE.
I. VERIFY ALL OPENING DIMENSIONS PRIOR TO WINDOW, DOOR AND DOOR
FRAME FABRICATION. DIMENSIONS GIVEN ARE APPROXIMATE.
J. JOINTS BETWEEN DISSIMILAR MATERIALS INCLUDING HORIZONTAL JOINTS
BETWEEN CONCRETE AND FOUNDATION WALL SHALL BE CAULKED.
K. PAINT OR STAIN EXPOSED WOOD SURFACE SURFACES WHICH ARE NOT
PREFINISHED. PAINT METAL SURFACES. SEE SPECIFICATIONS.
L. REMOVE LEAVES & DEBRIS FROM UNDER PORCHES.
M. ALL BASEMENT DOORS TO SWING AS EXISTING.
REMOVE CONCRETE STAIRS, RETAINING WALL AND FLOOR SLAB
REMOVE FLOOR DRAIN AND CAP LINE OUTSIDE OF WALL.
STEEL HANDRAILS AND ANCHORAGE TO BE COMPLETELY REMOVED.
REMOVE AND REPLACE DOOR AND FRAME.
TUCKPOINT LIMESTONE WHERE INDICATED. MATCH EXISTING MORTAR
COMPOSITION AND EXISTING JOINT TOOLING.
PATCH VERTICAL & HORIZONTAL CONCRETE SURFACES AS INDICATED
REMOVE LOOSE OR DETERIORATED CONCRETE TOPPING AT CURB
REPAIR VERTICAL AND HORIZONTAL SURFACES WITH MASONRY
PATCHING COMPOUND. SEE SPECIFICATIONS.
CONCRETE STAIRS, AREA WELL AND RETAINING WALL. SEE
DETAIL SHEET S1 (NEW).
PROVIDE STEEL GUARDRAILS AND HANDRAILS AT STAIRWELLS, AS
INDICATED. PROVIDED WALL MOUNTED HANDRAIL @ STAIR.
PROVIDE STEEL CLOSURE ON COAL CHUTE DOOR (PAINT). SEE
DETAIL SHEET S1.
LEGEND
PLAN @ BUILDING 45
SCALE: 1/16"=1'-0"PORCH LEVEL
SEE ELEVATIONS FOR
DOORS & WINDOWS IN BSM'T.
ALL SIZES TO BE VERIFIED BY FIELD MEASUREMENT
DOORS TO 7'-6"H - 3 BUTTS PER LEAF
DOORS 7'-6"H TO 9'-0" - 4 BUTTS PER LEAF
DOOR
NUMBER
DOOR SIZE
W x H x T
DOOR
TYPE
FRAME
TYPE QTY
FRAME
TYPE
FRAME DETAILS
HEAD JAMB SILL
HDWRE
GROUP REMARKS
DOOR SCHEDULE
SEE DOOR TYPES ABOVE
SEE DOOR TYPES ABOVE
SEE DOOR TYPES ABOVE
SEE DOOR TYPES ABOVE
WD WD
WD WD
WD WD
WD WD
MATCH
EXISTING
MATCH
EXISTING
MATCH
EXISTING
MATCH
EXISTING
9, 10
9, 10
WINDOW
ID
WINDOW SIZE
W x H x T
WINDOW TYPE
FRAME DETAILS
HEAD SILL
REMARKS
WINDOW SCHEDULE
A
B
C
D
SEE ABOVE DOUBLE HUNG
2,3
JAMB
E
E1
SEE ABOVE
SEE ABOVE
SEE ABOVE
SEE ABOVE
SEE ABOVE
DOUBLE HUNG
DOUBLE HUNG
DOUBLE HUNG
CASEMENT
CASEMENT
2,3
QTY.
5,6
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO REMAIN
WINDOW FRAME TO BE REMOVED
1" O.D. BARS (6 PER WINDOW)
WINDOW FRAME TO BE REMOVED
1" O.D. BARS (6 PER WINDOW)
9, 10
9, 10
Sc an ne d by S an ch ez
A ss oc ia te s, In c.
T el
: 3
-5
-7
Fa x:
-5
-3
- s an ch ez js an ch ez .c om w w w .js an ch ez .c om Fi le na m e:
D :\J ob s\
6-
Ar ch
-1 st
-E le v.
dw g D at e:
0/
/2
T im e:
8:
8/ 6/
1:
:0
AM
, P lo tte d by : J
. M
AT
TH
EW
S
AutoCAD SHX Text Missouri Air National Guard
AutoCAD SHX Text Jefferson Barracks NGB
AutoCAD SHX Text St. Louis, Missouri 63125
| Sheets and Views |
| Plot |
| PSALL |
File details come from the government source that posted it. Updated .