RFI 2 - 045-Arch-1st-Elev-Plot.pdf
PDF 247 KB Posted
- Solicitation number
- W50S8K24QA001
About this file
This document appears to be a Request for Information (RFI) related to architectural drawings and existing conditions of Building 45 at the Jefferson Barracks National Guard Base in St. Louis, Missouri. The drawings provide details on the building's exterior elevations, window and door schedules, and existing site conditions. The intent of this historical rehabilitation project is to identify, retain, and preserve the existing profile and style of the materials, while matching new materials as closely as possible. The scope of work includes cleaning and repointing of brick, window and door replacement, and miscellaneous repairs, but excludes work on the elevated porches. All work must comply with the Department of the Interior's standards for rehabilitation of registered national historic buildings.
The related federal contract opportunity is a solicitation (W50S8K24QA001) for the demolition of Buildings 45-47 at the same base. The work involves carefully demolishing the buildings so that materials can be salvaged and reused for repair work or reconstruction at another location. A pre-quote site visit has been scheduled, and interested parties should refer to the "Instructions to Quoters" section of the solicitation for more information.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M K
R
EV
IS
IO
N D
AT
E
D R
AW
N
C H
EC
KE
D
SC
AL
E
C
AT
EG
O
R Y
C O
D E
D
AT
E
D R
AW
IN
G N
O
AP
PR
O
VE
D B
Y
C H
EC
KE
D B
Y
D R
AW
N
B Y
SH
EE
T O
F
AI
R
NA
TI
ON
AL
GU
AR
D
CI
VI
L
E N G
IN
E
ER
IN
G
GEO
GRA
PH
IAE
S C
I EN
TIA
EQ
UE
CO
NF
IN
IA
PE
NE
TR
AM
US
NORTH
045-ARCH-1ST-ELEV
SCALE: 1/16"=1'-0"
SOUTH ELEVATION
SCALE: 1/16"=1'-0"
WEST ELEVATION BUILDING 45
SCALE: 1/16"=1'-0"
(EXISTING CONDITIONS)
GENERAL NOTES
KEYED NOTES
LEGEND
* SEE SHEET A4 FOR DETAILS
4'
-4
34'-1"
A. WORK ASSOCIATED WITH THE ELEVATED PORCHES, INCLUDING ROOFS,
CONCRETE DECK, AND BRICK REMOVAL AND REPLACEMENT ADJACENT TO THE
CONCRETE FLOOR DECK, IS NOT IN THIS CONTRACT. THIS SCOPE OF WORK
INCLUDES ONLY THE CLEANING AND REPOINTING OF BRICK OR AS
OTHERWISE INDICATED IN THESE DOCUMENTS.
B. THIS IS A HISTORICAL REHABILITION PROJECT. IT IS THE INTENT
TO IDENTIFY, RETAIN AND PRESERVE THE PROFILE AND STYLE OF EXISTING
MATERIALS. THE INTENT IS TO MATCH AS CLOSE AS POSSIBLE NEW MATERIALS
WITH EXISTING MATERIALS IN FORM AND DETAIL WHERE INDICATED. REFER TO
BUILDINGS 45,46 AND 47 EXISTING CONDITIONS.
C. ALL NEW WORK TO MEET THE REQUIREMENTS OF DEPARTMENT OF INTERIORS
STANDARDS FOR REHABILITATION OF REGISTERED NATIONAL HISTORIC BUILDINGS.
E. PROJECT ADJACENT WOOD TRIM, SOFFIT AND GUTTER AND DOWNSPOT AND
GROUNDING WIRE NOT IN CONTRACT FROM DAMAGE DURING CONSTRUCTION.
IF REMOVAL OF WALL ATTACHMENTS IS REQUIRED TO PERFORM THE WORK,
THE ATTACHMENT SHALL BE RESTORED TO ITS ORIGINAL SECURE
CONDITON. DAMAGED SURFACES SHALL BE REPAIRED TO THEIR ORIGINAL
F. CHIMNEYS ABOVE THE ROOF LINE ARE NOT WITHIN THE SCOPE OF WORK.
G. REMOVE ALL MISCELLANEOUS ANCHORS AND ATTACHMENTS FROM EXTERIOR OF
BRICK WALLS PRIOR TO TUCKPOINTING.
H. WINDOW SASH AND DOORS TO BE REMOVED. WINDOW AND DOOR FRAMES
ABOVE GRADE TO REMAIN. DOOR FRAMES BELOW GRADE TO BE REPLACED.
EXISTING EXTERIOR WOOD DOOR SND WINDOW HEAD TRIM SHALL BE
RETAINED AND RE-USED TO THE GREATEST EXTENT POSSIBLE. ALL
EXPOSED WOOD SURFACES CONTAIN LEAD-BASE PAINT. SEE
SPECIFICATIONS. EXISTING STEEL RAILINGS CONATAIN LEAD-BASE PAINT.
D. ALL EXPOSED BRICK EXTERIOR WALLS SHALL BE CLEANED, JOINTS RACKED
AND REPOINTED. DAMAGED, MISSING OR SPALLED BRICK UNITS AS
INDICATED SHALL BE REPLACED PRIOR TO POINTING. SEE
SPECIFICATIONS FOR MASONRY RESTORATION AND UNIT PRICING FOR
ADDITIONAL BRICK REPLACEMENT.
CONDITION AT CONTRACTOR'S EXPENSE.
I. VERIFY ALL OPENING DIMENSIONS PRIOR TO WINDOW, DOOR AND DOOR
FRAME FABRICATION. DIMENSIONS GIVEN ARE APPROXIMATE.
J. JOINTS BETWEEN DISSIMILAR MATERIALS INCLUDING HORIZONTAL JOINTS
BETWEEN CONCRETE AND FOUNDATION WALL SHALL BE CAULKED.
K. PAINT OR STAIN EXPOSED WOOD SURFACE SURFACES WHICH ARE NOT
PREFINISHED. PAINT METAL SURFACES. SEE SPECIFICATIONS.
L. REMOVE LEAVES & DEBRIS FROM UNDER PORCHES.
M. ALL BASEMENT DOORS TO SWING AS EXISTING.
REMOVE CONCRETE STAIRS, RETAINING WALL AND FLOOR SLAB
REMOVE FLOOR DRAIN AND CAP LINE OUTSIDE OF WALL.
STEEL HANDRAILS AND ANCHORAGE TO BE COMPLETELY REMOVED.
REMOVE AND REPLACE DOOR AND FRAME.
TUCKPOINT LIMESTONE WHERE INDICATED. MATCH EXISTING MORTAR
COMPOSITION AND EXISTING JOINT TOOLING.
PATCH VERTICAL & HORIZONTAL CONCRETE SURFACES AS INDICATED
REMOVE LOOSE OR DETERIORATED CONCRETE TOPPING AT CURB
REPAIR VERTICAL AND HORIZONTAL SURFACES WITH MASONRY
PATCHING COMPOUND. SEE SPECIFICATIONS.
CONCRETE STAIRS, AREA WELL AND RETAINING WALL. SEE
DETAIL SHEET S1.
PROVIDE STEEL GUARDRAILS AND HANDRAILS AT STAIRWELLS, AS
INDICATED. PROVIDE WALL MOUNTED HANDRAIL @ STAIR.
PROVIDE STEEL CLOSURE ON COAL CHUTE DOOR (PAINT). SEE
DETAIL SHEET S1.
DOOR
NUMBER
DOOR SIZE
W x H x T
DOOR
TYPE
FRAME
TYPE QTY
FRAME
TYPE
FRAME DETAILS
HEAD JAMB SILL
HDWRE
GROUP REMARKS
DOOR SCHEDULE
SEE ABOVE WD WD
WD WD
WD WD
WD WD
VERIFY
VERIFY
VERIFY
VERIFY
9, 10
9, 10
WINDOW
ID
WINDOW SIZE
W x H x T
WINDOW TYPE
FRAME DETAILS *
HEAD SILL
REMARKS
WINDOW SCHEDULE
A
B
C
D
SEE ABOVE DOUBLE HUNG
2,3
JAMB
E
E1
SEE ABOVE
SEE ABOVE
SEE ABOVE
SEE ABOVE
SEE ABOVE
DOUBLE HUNG
DOUBLE HUNG
DOUBLE HUNG
CASEMENT
CASEMENT
2,3
QTY.
5,6
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO REMAIN
WINDOW FRAMES TO BE REMOVED
1" O.D. BARS (6 PER WINDOW)
WINDOW FRAMES TO BE REMOVED
1" O.D. BARS (6 PER WINDOW)
9, 10
9, 10
SEE ABOVE
SEE ABOVE
SEE ABOVE
C A A A A A A D A A A A A A C B B B B
1 1 1 1
3 3 4 3 3 3
E E
E E E E E E E E E
2 2 2 2 2 2
2 SF
15 SF
2Ø SF 2Ø SF
2 SF 1Ø SF 1Ø SF 2 SF 2Ø SF 2Ø SF 2Ø SF
2Ø SF
1Ø SF5 SF
5 SF
TUCKPOINT
LIMESTONE
(TYP.)
COAL
CHUTE
PLATE & BOLT TO
REMAIN
REMOVE GOOSENECK
REMOVE CONDUIT
T/EXPOSED MASONRY
ELEV. 14'-0"
EXISTING FIN. FLOOR
ELEV.- 0'-0"
EXIST.BASEMENT FLOOR
ELEV.- 9'-0"
78'±X10'±W
AREAWELL & STAIRS TO BE REMOVED
REMOVE
GOOSENECK
CONDUIT
A A A A A A A A A A A A A A B B B B
E E1 E1 E1 E1 E1 E1 E1 E
1 2 1
ELEV. 14'-0"
T/EXPOSED MASONRY
EXISTING FIN. FLOOR
ELEV. 0'-0"
DS
E1
A 1
E1
DS
7 SF
DS DS DS
3 SF 2 SF 8 SF
MISSING OR LOOSE PORCH & STEPS
NOT IN CONTRACT
REMOVE PAINT FROM
BRICK (10-12 SF)
GROUND WIREPLATE & BOLT
TO REMAIN
A D A
15 Ø SFE 2 Ø SF
A D A
E 2 Ø SF
2 SF ±
3'-2" 5'-0"
5'-0" 6'-4"
2'-10" 3'-2"
6' -8
" T O
'-2
6' -8
" T O
'-2
'-1
" T O
2'
-2 1 2"
8' -6
'-1
" T O
2'
-2 1 2"
8' -6
1 2 3 4
INSULATING
GLASS (TYP.) FIXED CASEMENT
TRANSOMS (TYP.)
RAISED WOOD PANELDOORS TYPES
SCALE: 1/4"=1'-0"
ALL SIZES TO BE VERIFIED BY FIELD MEASUREMENT
DOORS TO 7'-6"H - 3 BUTTS PER LEAF
DOORS 7'-6"H TO 9'-0" - 4 BUTTS PER LEAF
5'-0"
3'-2" 3'-2"
2' -4
3'
-1
'-3
" T O
0'
-5 1 2"
7' -6
2' -4
3'
-1
D E E1
QUALITY OF DAMAGED, MISSING OR
SPALLED BRICK UNITS.
BASEMENT
HOPPERS (TYP.)
3'-2"
3'-2"
7' -6
'-3
" T O
0'
-5 1 2"
7' -6
A B
INSULATING GLASS (TYP.) EXISTING DECORATIVE
WOOD BLOCKING
EXISTING
STONE SILL
DOUBLE HUNG (TYP.)
WINDOW TYPES
SCALE: 1/4"=1'-0"
3'-2"
7' -6
C
FULL HEIGHT SCREENS AT
DOUBLE HUNG WINDOWS (TYPICAL)
PORCHES
NOT IN CONTRACT
A D A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
A
C
A
B
A
A
A
A
ADA
B
B
A
A
A
D
A
A
A
A
B
C
5 6
5 6
5 6
BRICKS 20' ±
'-4
'-1
1"
'-0
8' -0
'-0
'-5
18'
PORCH
NOT IN
CONTRACT
4" CONCRETE
SLAB ON GRADE
NEW STAIRS
& AREA WELL
INSTALL NEW WALL
IN LOCATION OF
EXISTING WALL.
COORDINATE W/DOOR
OPENING
4"CONCRETE
SLAB ON GRADE
NEW STAIRS AND
AREA WELL
NEW 6" PVC &
AREA DRAINS -SEE C-1
SLOPE TO DRAIN(TYP.)
2"
NEW 4" CONCRETE
SLAB ON GRADE
NEW STAIRS AND
AREA WELL
10'-3"
PORCH
NOT IN
CONTRACT
5 SF HORIZONTAL PATCH
D N
10 SF
2"
EAST ELEVATION BUILDING 45
SCALE: 1/16"=1'-0"
(EXISTING CONDITIONS)
PLAN @ BUILDING 45
SCALE: 1/16"=1'-0"PORCH LEVEL
SEE ELEVATIONS FOR
DOORS & WINDOWS IN BSM'T.
NORTH ELEVATION
SCALE: 1/16"=1'-0"
Sc an ne d by S an ch ez
A ss oc ia te s, In c.
T el
: 3
-5
-7
Fa x:
-5
-3
- s an ch ez js an ch ez .c om w w w .js an ch ez .c om Sc an ne d by
S an ch ez
A ss oc ia te s, In c.
T el : 3
-5
-7
Fa x:
-5
-3
- s an ch ez js an ch ez
.c om w w w
.js an ch ez
.c om
Fi le na m e:
D
:\J ob s\ M
AN
G
Je ffe rs on B ar ra ck s sc an s
- J oh n
- S on nt ag
\0
\0
-A rc h- 1s t-E le v.
dw g D at e:
0/
/2
T im e:
1:
8/ 6/
1:
:1
AM
, P lo tte d by : J
. M
AT
TH
EW
S
AutoCAD SHX Text Missouri Air National Guard
AutoCAD SHX Text Jefferson Barracks NGB
AutoCAD SHX Text St. Louis, Missouri 63125
| Sheets and Views |
| Plot |
| PSALL |
File details come from the government source that posted it. Updated .