Specs VBDZ252200 Repair Bldg 2A Sewer Line.pdf
PDF 16 MB Posted
- Solicitation number
- W50S8J26Q0001
About this file
This document is a comprehensive product specification and submittal package for the SANG C-130 Flight Sim project, containing detailed technical specifications and drawings for plumbing fixtures, bathroom accessories, and related components required for a commercial bathroom installation.
The package includes specifications for multiple product categories: a shower enclosure (Comfort Designs Model XST 3938 BF.75 with backing placement drawings), an elongated flushometer toilet (American Standard AFWALL Millennium FloWise 2257.101 with roughing-in dimensions), a commercial toilet seat (American Standard 5901.100SS with self-sustaining hinge and EverClean surface), a universal urinal (American Standard Washbrook FloWise 6590.001 with sensor-operated flushing), sensor flushometers (Sloan Royal 111 ESS Hardwired 1.28 GPM and Sloan Royal Optima 186-0.125 DBP), an undercounter sink (Just Manufacturing UOIF-ADA-1521-A oval lavatory with overflow), a kitchen faucet (Delta B4310LF single handle deck mount), a center outlet waste (McGuire 113C21G20), and various plumbing accessories including p-traps (McGuire C8912CECO), supply stops (McGuire LFST02LK), thermostatic mixing valve (Symmons TempControl 7-400B with vacuum breaker), booster pumps (Bell & Gossett Series PL with specifications for model PL-30), rough valve bodies (American Standard Flash RU101), and supporting components such as water supply connectors, escutcheons, strainers, and test cocks. All products are specified with ADA compliance requirements, specific finishes (primarily polished chrome and white), and detailed roughing-in dimensions for installation. The submittal demonstrates compliance with ASME, CSA, ANSI, and IAPMO standards, with all fixtures and accessories designed for commercial applications requiring durability and accessibility features.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI Log - Updated 21 April 26.xlsx | XLSX spreadsheet | |
| 251210049-1180A-STRAT_AB.pdf | ||
| P101.pdf | ||
| RFI Log.xlsx | XLSX spreadsheet | |
| P201.pdf | ||
| Site Visit Minutes.pdf | ||
| Repair B2A Sewer Line Restroom and Lockers Slides.pptx | PPTX presentation | |
| Site Visit Sign In Sheet.pdf | ||
| WD NY20260002 Mod 1.txt | TXT text file | |
| Provisions and Clauses.pdf | ||
| SOW-Spec-Drawings VBDZ252200.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MOUNT RIM AT 17"
FOR ADA HEIGHT
MOUNT AT 17" FOR
ADA HEIGHT.
MOUNT AT STANDARD
HEIGHT - 24" ABOVE FLOOR
NOTE:
COORDINATE INSTALLATION
LOCATION AND WIRING WITH
ELECTRICAL CONTRACTOR.
NOTE:
COORDINATE INSTALLATION
LOCATION AND WIRING WITH
ELECTRICAL CONTRACTOR.
PROVIDE WITH VACUUM BREAKER
PER CONTRACT DOCUMENTS
| MicrosoftIRMServices Protected PDF |
| Showers |
| General Plumbing Fixtures |
File details come from the government source that posted it. Updated .