Specs VBDZ252200 Repair Bldg 2A Sewer Line.pdf

PDF 16 MB Posted

Attached to
109 AW - Repair Building 2A Sewer Line, Restrooms, and Lockers
Solicitation number
W50S8J26Q0001
Issued by

About this file

This document is a comprehensive product specification and submittal package for the SANG C-130 Flight Sim project, containing detailed technical specifications and drawings for plumbing fixtures, bathroom accessories, and related components required for a commercial bathroom installation.

The package includes specifications for multiple product categories: a shower enclosure (Comfort Designs Model XST 3938 BF.75 with backing placement drawings), an elongated flushometer toilet (American Standard AFWALL Millennium FloWise 2257.101 with roughing-in dimensions), a commercial toilet seat (American Standard 5901.100SS with self-sustaining hinge and EverClean surface), a universal urinal (American Standard Washbrook FloWise 6590.001 with sensor-operated flushing), sensor flushometers (Sloan Royal 111 ESS Hardwired 1.28 GPM and Sloan Royal Optima 186-0.125 DBP), an undercounter sink (Just Manufacturing UOIF-ADA-1521-A oval lavatory with overflow), a kitchen faucet (Delta B4310LF single handle deck mount), a center outlet waste (McGuire 113C21G20), and various plumbing accessories including p-traps (McGuire C8912CECO), supply stops (McGuire LFST02LK), thermostatic mixing valve (Symmons TempControl 7-400B with vacuum breaker), booster pumps (Bell & Gossett Series PL with specifications for model PL-30), rough valve bodies (American Standard Flash RU101), and supporting components such as water supply connectors, escutcheons, strainers, and test cocks. All products are specified with ADA compliance requirements, specific finishes (primarily polished chrome and white), and detailed roughing-in dimensions for installation. The submittal demonstrates compliance with ASME, CSA, ANSI, and IAPMO standards, with all fixtures and accessories designed for commercial applications requiring durability and accessibility features.

View the file

Other files

File Type Posted
RFI Log - Updated 21 April 26.xlsx XLSX spreadsheet
251210049-1180A-STRAT_AB.pdf PDF
P101.pdf PDF
RFI Log.xlsx XLSX spreadsheet
P201.pdf PDF
Site Visit Minutes.pdf PDF
Repair B2A Sewer Line Restroom and Lockers Slides.pptx PPTX presentation
Site Visit Sign In Sheet.pdf PDF
WD NY20260002 Mod 1.txt TXT text file
Provisions and Clauses.pdf PDF
SOW-Spec-Drawings VBDZ252200.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MOUNT RIM AT 17"

FOR ADA HEIGHT

MOUNT AT 17" FOR

ADA HEIGHT.

MOUNT AT STANDARD

HEIGHT - 24" ABOVE FLOOR

NOTE:

COORDINATE INSTALLATION

LOCATION AND WIRING WITH

ELECTRICAL CONTRACTOR.

NOTE:

COORDINATE INSTALLATION

LOCATION AND WIRING WITH

ELECTRICAL CONTRACTOR.

PROVIDE WITH VACUUM BREAKER

PER CONTRACT DOCUMENTS

MicrosoftIRMServices Protected PDF
Showers
General Plumbing Fixtures

File details come from the government source that posted it. Updated .