This is a Bulk Asbestos Report prepared by Adirondack Environmental Services, Inc. for Stratton Air National Guard in Scotia, New York, dated December 19, 2025 (Work Order 251210049).

The report documents analysis of four bulk samples collected on December 9, 2025, from floor tile and Hardiebacker materials at the facility. Two floor tile samples (001A and 001B) were analyzed using PLM method ELAP 198.6. Sample 001A (white, non-friable material) returned an inconclusive result with trace chrysotile asbestos (<1%) by PLM and was confirmed as Non-Asbestos Containing (NAC) by TEM analysis. Sample 001B (yellow, non-friable mastic/adhesive material) tested negative for asbestos and received a NAC designation. Two Hardiebacker samples (002A and 002B) both tested positive as Asbestos Containing Material (ACM). Sample 002A (gray, friable material) contained 2.4% chrysotile asbestos. Sample 002B (black, non-friable mastic/adhesive material) contained 10.9% chrysotile asbestos. All analysis was conducted using New York State Department of Health ELAP methods 198.1, 198.4, and 198.6, with PLM analysis performed December 12, 2025, and TEM analysis performed December 19, 2025, both by analyst KSI. The laboratory is accredited under AIHA-LAP, LLC (#100307) and NYSDOH (#10709).

View the file

Other files

File Type Posted
RFI Log - Updated 21 April 26.xlsx XLSX spreadsheet
P101.pdf PDF
RFI Log.xlsx XLSX spreadsheet
P201.pdf PDF
Specs VBDZ252200 Repair Bldg 2A Sewer Line.pdf PDF
Site Visit Minutes.pdf PDF
Repair B2A Sewer Line Restroom and Lockers Slides.pptx PPTX presentation
Site Visit Sign In Sheet.pdf PDF
WD NY20260002 Mod 1.txt TXT text file
Provisions and Clauses.pdf PDF
SOW-Spec-Drawings VBDZ252200.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Experience is the solution 314 North Pearl Street Albany, New York 12207

(800) 848-4983 (518) 434-4546 Fax (518) 434-0891

Bulk Asbestos Report

Stratton ANG

1 Air National Guard Rd

Scotia, NY 12302

Project:

ProjLocation: Floor Tile, Hardiebacker

Date Sampled: 12/09/2025

Date Received: 12/10/2025

PLM Analyzed: 12/12/2025 by KSI

Method References: NYSDOH ELAP 198.1/198.4/198.6 TEM Analyzed:

AIHA-LAP,LLCAccredited#100307

NYSDOH#10709

KSI12/19/2025 by

WorkOrder: 251210049 L a y e r

Lab

ID

Sample Identification and Description

Materials Type

Non-asbestos Fibers

(Percent and Type) Asbestos

(Percent and Type) PLM Result

TEM Result Final

Status

ReportDate: 12/19/2025 of Residue

PLM

ELAP-198.4

001 Floor Tile1A Homogeneous, White,Non-Friable Material

42.1 Wt % Remaining

<1%

Inconclusive**

Trace <1%

NAC

CHRYSOTILE

PLMMethod: ELAP 198.6

No asbestos detected Floor Tile

001 Floor Tile1B Homogeneous, Yellow,Non-Friable Material

0 Wt % Remaining

<1%

NAC

------- <1%

NAC

PLMMethod: ELAP 198.6

Mastic/Adh/Glue

002 Hardiebacker2A Homogeneous, Gray,Friable Material

2.4%

ACM

------- 2.4%

ACM

PLMMethod: ELAP 198.1

Chrysotile Friable Material 2.4%

002 Hardiebacker2B Homogeneous, Black,Non-Friable Material

27.3 Wt % Remaining

10.9%

ACM

------- 10.9%

ACM

PLMMethod: ELAP 198.6

Chrysotile Mastic/Adh/Glue 40%

WorkOrder: 251210049 L a y e r

Lab

ID

Sample Identification and Description

Materials Type

Non-asbestos Fibers

(Percent and Type) Asbestos

(Percent and Type) PLM Result

TEM Result Final

Status

ReportDate: 12/19/2025 of Residue

PLM

ELAP-198.4

Approved by:____________________ Tara Daniels

ACM:Asbestos Containing Material

NAC:Non-Asbestos Containing Material

**A negative result for an NOB sample is considered inconclusive. The following NYS ELAP disclaimer applies:"PLM is not consistently reliable in detecting asbestos in floor coverings and similar NOB materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made using transmission electron microscopy(TEM)". Laboratory Director