This document package includes mechanical equipment schedules and specifications for replacing HVAC systems at Charlotte Douglas International Airport. The schedules list air handling units, chillers, boilers, pumps, air conditioning equipment, and terminal boxes to be provided. Key details include specifications for new split system heat pumps, DX cooling with gas furnaces, packaged rooftop units, computer room split systems, and a vertical air conditioner. Sizes, capacities, manufacturers, and technical requirements are provided for each piece of mechanical equipment. The related federal contract opportunity is solicitation number W50S87-20-B-5002 for replacing HVAC equipment and systems at Charlotte, issued by the Department of the Army North Carolina Army National Guard. Interested bidders are encouraged to attend a pre-bid conference on May 13, 2020. The document package provides specifications for the mechanical scope of work.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NONE
PROJECT MANAGER
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
D. WORLEY
D. WORLEY
M. DIMOFF
CONTRACT #: W9133L-15-D-0004
ANG PROJECT #: FJRP142610
HDR PROJECT #: 10137178
CHARLOTTE DOUGLAS INT'L AIRPORTREPLACE HVAC SYSTEMS
BASE WIDE - CHARLOTTE
NC AIR NATIONAL GUARD
145TH AIRLIFT WING
CHARLOTTE, NC
99M001
N. OVERBY
10137178-02-MP_Master.rvt
MECHANICAL SCHEDULES
7. HINGED DOOR ACCESS
6. DOUBLE WALL SEALED PANEL (R-13) AND LEVEL II THERMAL BREAK
5. PROVIDE UNIT WITH CONFIGURATION AND COMPONENTS AS SHOWN ON PLANS. UNIT SHALL FIT WITHIN SCHEDULED FOOTPRINT.
4. CONTRACTOR TO SET OUTSIDE AIR DAMPER AND SUPPLY AIR RATES EQUAL TO THE ORIGINAL EQUIPMENT OPERATION.
3. VFD ON SUPPLY FAN
2. INTERLOCK CONTROLLER WITH EXISTING BMS
1. SINGLE POINT POWER CONNECTION AND CONTROLLER FOR COMPLETE OPERATION AS NOTED ON PLANS AND SPECIFICATIONS.
NOTES:
02AHU-3 MECH. ROOM 8,000 NOTE 4 80 67 10 2.0 1,800 2 8 14 473 1.1 2 MERV 8 208 / 3 31 50 25 84 x 90 x 96 3080 02HP-3 CARRIER 39MN 17W 1 - 7
02AHU-2 MECH. ROOM 15,000 NOTE 4 80 67 20 2.0 1,800 2 8 14 490 0.49 2 MERV 8 208 / 3 60 100 48 96 x 104 x 120 5001 02HP-2A & 02HP-2B CARRIER 39MN 30W 1 - 7
DB
(°F)
WB
(°F)
HP
E.S.P.
(I.W.C.)
RPM
MAX
# OF
CIRCUITS
# OF
ROWS
FINS PER
INCH
VELOCITY
(FPM)
AIR PRESSURE
DROP (in W.G.)
FILTER THK
(IN)
FINAL
FILTER
VOLTAGE /
PHASE
MCA MOCP FAN FLA
SIZE
(L" x W" x H")
WEIGHT
(LBS)
MANUFACTURER MODEL
MARK LOCATION
NOMINAL
AIRFLOW
(CFM)
MINIMUM
OA (CFM)
ENT. COND FANS COILS FILTERS ELECTRICAL PHYSICAL
MATCHING COND.
UNIT
BASIS OF DESIGN
NOTES
SPLIT SYSTEM AIR HANDLER UNIT SCHEDULE
6. DIGITAL COMPRESSOR
5. LOW AMBIENT HEAD PRESSURE CONTROL
4. BACNET COMMUNICATIONS AND TIE IN TO EXISTING BMS
3. HAIL GUARDS
2. COMPRESSOR SUCTION SERVICE VALVE
1. DISCONNECT
NOTES:
45CH-1 OUTDOORS - EAST BLDG 45 70 95 / 78 R410A 54.0 44.0 164.8 12.0 0.0001 5 SCROLL 27 179 5 2.9 156 175 460 / 3 151 x 88 x 78 3400 CARRIER 30RAP070 1 - 6
EWT
(°F)
LWT
(°F)
GPM
PRESS.
DROP (FT)
FOUL
FACTOR
QTY TYPE
RLA
(EA.)
LRA
(EA.)
FAN NO.
FAN FLA
(EA.)
MCA MOCP
VOLTAGE /
PHASE
SIZE
(L"xW"xH")
WEIGHT
(LBS)
MANUFACTURER MODEL
MARK LOCATION SERVES
TOTAL
CAPACITY
(TONS)
AMB TEMP
DB/WB °F
REFRIG.
EVAPORATOR DATA COMPRESSOR DATA CONDENSER DATA ELEC DATA PHYSICAL DATA BASIS OF DESIGN
NOTES
AIR COOLED CHILLER SCHEDULE
4. COOLING CAPACITY BASED ON 95°F OUTDOOR AIR TEMPERATURE.
3. DISCONNECT SWITCH
2. HAIL GUARD
1. 2-STAGE SCROLL COMPRESSOR WITH LOW AMBIENT CONTROL.
NOTES:
02HP-3 OUTDOORS - WEST AHU-3 232 181 11.0 214 130 4 1/4 2 80 / 67 R-410A 30.1 225 73.7 100 208 / 3 86.4 x 67.1 x 50.4 800 CARRIER 38AUQB25A0M5 1 - 4
02HP-2B OUTDOORS - NORTH AHU-2 232 181 11.0 214 130 4 1/4 2 80 / 67 R-410A 30.1 225 73.7 100 208 / 3 86.4 x 67.1 x 50.4 800 CARRIER 38AUQB25A0M5 1 - 4
02HP-2A OUTDOORS - NORTH AHU-2 232 181 11.0 214 130 4 1/4 2 80 / 67 R-410A 30.1 225 73.7 100 208 / 3 86.4 x 67.1 x 50.4 800 CARRIER 38AUQB25A0M5 1 - 4
TOTAL SENSIBLE EER @47F @17F RLA LRA
COOLING HEATING FAN
NO.
FAN
HP
COMP
NO.
ENT. AIR
DB / WB °F
REFRIG.
COMPRESSOR
MCA MOCP
VOLTAGE /
PHASE
SIZE (L"xW"xH")
WEIGHT
(LBS.)
MANUFACTURER MODEL
MARK LOCATION SERVES
CAPACITY (MBH) CONDENSER DATA ELECTRICAL DATA PHYSICAL BASIS OF DESIGN
NOTES
SPLIT SYSTEM HEAT PUMP SCHEDULE
8. HOT GAS REHEAT HUMIDITY CONTROL
7. EXTERNAL STATIC PRESSURE TO BE SET EQUAL TO THE MEASURED EXTERNAL STATIC PRESSURE RECORDED IN THE T&B REPORT PERFORMED PRIOR TO START OF CONSTRUCTION
6. HINGED DOORS
5. OUTSIDE AIR DAMPER SHALL BE SET TO PROVIDE FRESH AIR EQUAL TO THE MEASURED OUTSIDE AIRFLOW RECORDED IN T&B REPORT PERFORMED PROIR TO START OF CONSTRUCTION.
4. DISCHARGE AIR AND OUTSIDE AIR TEMPERATURE SENSORS
3. LOW AMBIENT CONTROL
2. MANUFACTURER'S ROOF CURB ADAPTER
1. 2-STAGE SCROLL COMPRESSOR
NOTES:
61RTU-7 2 800 NOTE 6 NOTE 8 DIRECT - 1/2 23.0 18.0 R410A 60 49 -- 208 / 1 19.4 30 32.6 x 48.8 x 44.1 344 12 15 CARRIER 48VG-A240603 1 - 7
61RTU-6 5 2000 NOTE 6 NOTE 8 DIRECT 1.06 -- 63.0 48.3 R410A 110 88 16 x 16 x 2 208 / 3 29 40 74 x 47 x 41 650 12 16 CARRIER 48GCEN06B1A5 1 - 8
61RTU-5 4 1600 NOTE 6 NOTE 8 DIRECT 0.72 -- 50 37 R410A 67 53 16 x 25 x 2 208 / 3 24 30 73 x 47 x 41 600 12 16 CARRIER 48GCDN05B1A5 1 - 8
61RTU-4 4 1600 NOTE 6 NOTE 8 DIRECT 0.72 -- 50 37 R410A 67 53 16 x 25 x 2 208 / 3 24 30 72 x 47 x 41 600 12 16 CARRIER 48GCDN05B1A5 1 - 8
61RTU-3 8.5 3400 NOTE 6 NOTE 8 BELT 1.7 -- 103.6 81.0 R410A 125 103 20 x 20 x 2 208 / 3 39 50 88 x 59 x 49 1000 12 -- CARRIER 48HCDE09B1A5 1 - 8
61RTU-2 5 2000 NOTE 6 NOTE 8 DIRECT 1.06 -- 63.0 48.3 R410A 67 53 16 x 16 x 2 208 / 3 29 40 74 x 47 x 41 650 12 16 CARRIER 48GCDN06B1A5 1 - 8
61RTU-1 2 800 NOTE 6 NOTE 8 DIRECT - 1/2 23.0 18.0 R410A 60 49 -- 208 / 1 19.4 30 32.6 x 48.8 x 44.1 344 12 15 CARRIER 48VG-A240603 1 - 7
49RTU-1 2 800 NOTE 6 NOTE 8 DIRECT - 1/2 23.0 18.0 R410A 60 49 -- 208 / 1 19.4 30 32.6 x 48.8 x 44.1 344 12 15 CARRIER 48VG-A240603 1 - 7
(MBH) (MBH) (MBH)
TOTAL
(MBH)
SENSIBLE REFRIG.
TYPE
INPUT OUTPUT VOLTAGE
/ PHASE
MCA MOCP
AIRFLOW
(CFM)
OUTDOOR
AIRFLOW
(CFM)
E.S.P
(IN. WG.)
DRIVE BHP HP MANUFACTURER MODEL NO.
MARK
NO.
NOMINAL
TONS
SUPPLY COOLING CAPACITY
(AT 95F AMBIENT)
HEATING
CAPACITY FILTER
SIZE
(L"xW"xH")
ELECTRICAL
UNIT SIZE
(L"xW"xH")
WEIGHT
(LBS)
EER SEER
BASIS OF DESIGN
NOTES
GAS PACKAGED ROOFTOP UNIT SCHEDULE
MAR 2020 B-3 DESIGN SUBMITTAL
NOTE: "EQUAL TO" MANUFACTURERS CAN BE SUBMITTED FOR ALL UNITS DESCRIBED IN THE
SCHEDULE AS LONG AS THEY MEET OR EXCEED THE PERFORMANCE AND SPECIFICATIONS
OF THE BASIS OF DESIGN. A SUBSTITUTION REQUEST MUST BE SUBMITTED TO THE
CONTRACTING OFFICER DURING CONSTRUCTION FOR APPROVAL. SEE SPEC SECTION 01 33 00.
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
D. WORLEY
D. WORLEY
M. DIMOFF
CONTRACT #: W9133L-15-D-0004
ANG PROJECT #: FJRP142610
HDR PROJECT #: 10137178
CHARLOTTE DOUGLAS INT'L AIRPORTREPLACE HVAC SYSTEMS
BASE WIDE - CHARLOTTE
NC AIR NATIONAL GUARD
145TH AIRLIFT WING
CHARLOTTE, NC
99M002
N. OVERBY
10137178-02-MP_Master.rvt
MECHANICAL SCHEDULES
9. EXISTING CONDENSING UNIT TO REMAIN. INTERLOCK NEW FURNACE UNIT WITH EXISTING THERMOSTAT/CONTROLS.
8. VARIABLE SPEED SUPPLY FAN
7. CRANKCASE HEATER
6. LOW AMBIENT CONTROL
5. OUTSIDE AIR DAMPER SHALL BE SET TO PROVIDE FRESH AIR EQUAL TO THE MEASURED OUTSIDE AIRFLOW RECORDED IN T&B REPORT PERFORMED PROIR TO START OF CONSTRUCTION.
4. DISCONNECT SWITCH
3. WALL MOUNTED PROGRAMMABLE THERMOSTAT/CONTROLLER WITH BACNET CAPABILITY TO TIE IN TO EXISTING BMS
2. R-410A REFRIGERANT
1. COOLING CAPACITY BASED ON 95º F OUTDOOR AIR TEMPERATURE
NOTES:
69CU-1 / 69GF-1 3 R410A 14.5 1200 NOTE 5 0.5 0.5 115 / 1 70 60 59 17" 80 / 67 32.7 25.9 17.8 30 208 / 1 186 CARRIER 24ACA436C003 CAPMP3617ALA 59MN7A060V17-14 1 - 8
67CU-3 / 67GF-3 4 R410A 14.5 1600 NOTE 5 0.5 1.0 115 / 1 70 80 78 21" 80 / 67 44.3 33.7 8.4 15 460 / 3 243 CARRIER 24AHA448A006 CAPMP4821ALA 59MN7A080V21--20 1 - 8
67CU-2 / 67GF-2 4 R410A 14.5 1600 NOTE 5 0.5 1.0 115 / 1 70 80 78 21" 80 / 67 44.3 33.7 8.4 15 460 / 3 243 CARRIER 24AHA448A006 CAPMP4821ALA 59MN7A080V21--20 1 - 8
67CU-1 / 67GF-1 5 R410A 14.5 1800 NOTE 5 0.5 1.0 115 / 1 70 98 95 21" 80 / 67 57.8 43.4 9.7 15 460 / 3 245 CARRIER 24AHA460A006 CAPMP6021ALA 59MN7A10021-20 1 - 8
63CU-7 / 63GF-7 3 R410A 14.5 1000 NOTE 5 0.5 0.5 115 / 1 70 60 59 17" 80 / 67 33.1 24.6 -- -- 208 / 1 214 CARRIER 24AHA436A006 CAPMP3617ALA 59MN7A060V17-14 1 - 8
63CU-6 / 63GF-6 4 R410A 14.5 1700 NOTE 5 0.5 1.0 115 / 1 70 80 78 21" 80 / 67 44.3 33.7 8.4 15 460 / 3 243 CARRIER 24AHA448A006 CAPMP4821ALA 59MN7A080V21--20 1 - 8
63CU-5 / 63GF-5 3 R410A 14.5 1200 NOTE 5 0.5 0.5 115 / 1 70 60 59 17" 80 / 67 33.6 26.39 7.6 15 460 / 3 214 CARRIER 24AHA436A006 CAPMP3617ALA 59MN7A060V17-14 1 - 8
63GF-4 4 R410A 14.5 1400 NOTE 5 0.5 1.0 115 / 1 70 80 78 21" 80 / 67 44.3 33.7 EXISTING CARRIER EXISTING CAPMP4821ALA 59MN7A080V21--20 1 - 5 , 8 , 9
63GF-3 5 R410A 14.5 1800 NOTE 5 0.5 1.0 115 / 1 70 98 95 21" 80 / 67 57.8 43.4 EXISTING CARRIER EXISTING CAPMP6021ALA 59MN7A10021-20 1 - 5 , 8 , 9
63CU-2 / 63GF-2 4 R410A 14.5 1500 NOTE 5 0.5 1.0 115 / 1 70 80 78 21" 80 / 67 44.3 33.7 8.4 15 460 / 3 243 CARRIER 24AHA448A006 CAPMP4821ALA 59MN7A080V21--20 1 - 8
63GF-1 5 R410A 14.5 1800 NOTE 5 0.5 1.0 115 / 1 70 98 95 21" 80 / 67 57.8 43.4 EXISTING CARRIER EXISTING CAPMP6021ALA 59MN7A10021-20 1 - 5 , 8 , 9
TOTAL SENSIBLE
HP
VOLTAGE /
PHASE
EAT (°F)
INPUT
(MBH)
OUTPUT
(MBH)
CABINET
WIDTH
EAT db/wb °F
CAPACITY (MBH)
MCA MOCP
VOLTAGE /
PHASE
DX COIL FURNACE / AHU
DESIGN
CFM
OA CFM
E.S.P.
(IN WG)
FAN DATA GAS HEATING DATA DX COOLING COIL DATA ELECTRICAL
WEIGHT
(LBS)
MANUFACTURER OUTDOOR UNIT
MARK
NO.
NOMINAL
TONS
REFRIG. SEER
INDOOR UNIT OUTDOOR UNIT BASIS OF DESIGN
NOTES
SPLIT SYSTEM DX COOILING W/GAS FURNACE SCHEDULE
8. VARIABLE SPEED SUPPLY FAN
7. CRANKCASE HEATER
6. LOW AMBIENT CONTROL
5. CONTRACTOR TO SET OUTSIDE AIR DAMPER AND SUPPLY AIR RATES EQUAL TO THE ORIGINAL EQUIPMENT OPERATION
4. DISCONNECT SWITCH
3. WALL MOUNTED PROGRAMMABLE THERMOSTAT/CONTROLLER WITH BACNET CAPABILITY TO TIE IN TO EXISTING BMS
2. R-410A REFRIGERANT
1. COOLING CAPACITY BASED ON 95º F OUTDOOR AIR TEMPERATURE
NOTES:
67CU-4 / 67AH-4 1.5 R410A -- / 14.0 600 NOTE 5 0.4 0.33 208 / 1 26.1 30 5 THROWAWAY 2 18.0 9.6 17.8 13.6 208 / 1 11.8 20 170 CARRIER 25HCC518A003 FB4CNP018L05 1 - 8
DESIGN
CFM
OA CFM
E.S.P.
(IN WG)
HP
VOLTAGE /
PHASE
MCA MOCP
AUX. HEAT
(kW)
TYPE
THICKNESS
(in.)
@47°F
(MBH)
@17°F
(MBH)
TOTAL
(MBH)
SENSIBLE
(MBH)
VOLTAGE /
PHASE
MCA MOCP
FAN DATA ELECTRICAL DATA FILTER DATA HEATING CAPACITY COOLING CAPACITY ELECTRICAL DATA
WEIGHT
(LBS)
MANUFACTURER
HEAT PUMP UNIT
(OUTDOOR)
AIR HANDLING UNIT
(INDOOR)
MARK
NO.
NOMINAL
TONS
REFRIG.
SEER /
EER
INDOOR UNIT OUTDOOR UNIT BASIS OF DESIGN
NOTES
SPLIT SYSTEM HEAT PUMP SCHEDULE
8. VARIABLE SPEED, EC PLUG FANS (QTY 2)
7. DIGITAL SCROLL COMPRESSORS / DUAL CIRCUIT
6. DISCONNECT
5. STEAM CANISTER HUMIDIFIER
4. NETWORK INTERFACE CARD TO CONNECT TO EXISTING BMS
3. DUCT KIT, HIGH TEMPERATURE STAT, AND FILTER CLOG INDICATOR
2. MODULATING HOT GAS REHEAT AND LOW AMBIENT CONTROL
1. WALL MOUNTED CONTROLLER FOR COMPLETE OPERATION AS NOTED ON PLANS AND SPECIFICATIONS
NOTES:
45AC-4 2ND FLOOR 885 - 75 50 1/2 0.3 - - 21.8 16.7 - 4.7 4.3 2 MERV 8 208 / 1 16.4 25 13.4 208/1 42.8 45 34.2 45CU-4 LEIBERT PFH027A-PLN MMD24ENPHE 1 - 6
45AC-3 2ND FLOOR 8,000 - 75 50 -- 0.3 - - 203 162 - 25 22 4 MERV 8 460 / 3 6.3 15 5.6 460 / 3 69.4 70 57.1 45CU-3 LEIBERT MCL110E8 DS053ADA1E1 1 - 8
45AC-2 2ND FLOOR 750 -- 75 50 0.2 0.3 - - 18.4 15.3 - 2.5 2 MERV 8 208 / 1 14.8 25 12.1 208 / 1 7.8 15 6.2 45CU-2 LEIBERT PFH020A-PLN MMD18ENPH0 1 - 6
45AC-1 2ND FLOOR 750 -- 75 50 0.2 0.3 - - 18.4 15.3 - 2.5 2 MERV 8 208 / 1 14.8 25 12.1 208 / 1 7.8 15 6.2 45CU-1 LEIBERT PFH020A-PLN MMD18ENPH0 1 - 6
DB
(°F)
RH
(%) HP
E.S.P.
(I.W.C.)
RPM
MAX
HEATING
TOT. (MBH)
COOLING
TOT. (MBH)
COOLING
SENS (MBH)
HOT GAS
REHEAT (MBH)
FILTER THK
(IN)
FINAL
FILTER
VOLTAGE /
PHASE
MCA MOCP FLA
VOLTAGE /
PHASE
MCA MOCP FLA MANUFACTURER
MODEL
(OUTDOOR)
MODEL
(INDOOR)
MARK LOCATION
NOMINAL
AIRFLOW
(CFM)
MINIMUM
OA (CFM)
ENT. COND INDOOR FAN COILS ELECTRIC
REHEAT COIL
(kW)
STEAM
HUMIDIFIER
(LB/HR)
FILTERS ELECTRICAL (OUTDOOR) ELECTRICAL (INDOOR)
MATCHING
HEAT PUMP
BASIS OF DESIGN
NOTES
COMPUTER ROOM SPLIT SYSTEM SCHEDULE
MAR 2020 B-3 DESIGN SUBMITTAL
NOTE: "EQUAL TO" MANUFACTURERS CAN BE SUBMITTED FOR ALL UNITS DESCRIBED IN THE
SCHEDULE AS LONG AS THEY MEET OR EXCEED THE PERFORMANCE AND SPECIFICATIONS
0 1" 2"
SCALE
FILENAME
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUE DATE DESCRIPTION
1 2 3 4 5 6 7 8
D
C
B
A
SHEET
D. WORLEY
D. WORLEY
M. DIMOFF
CONTRACT #: W9133L-15-D-0004
ANG PROJECT #: FJRP142610
HDR PROJECT #: 10137178
CHARLOTTE DOUGLAS INT'L AIRPORTREPLACE HVAC SYSTEMS
BASE WIDE - CHARLOTTE
NC AIR NATIONAL GUARD
145TH AIRLIFT WING
CHARLOTTE, NC
99M003
N. OVERBY
10137178-02-MP_Master.rvt
MECHANICAL SCHEDULES
3. CONDENSATE NUETRALIZATION KIT
2. BOILER OPERATING POINTS AND WATER SETPOINTS TO MATCH EXISTING SYSTEM OPERATION
1. ASME CSD-1 DDC CONTROLS THAT CAN BE INTEGRATED BUILDING DDC CONTROLS SYSTEMS, FM FUEL TRAIN AND SAFETY TRIM
NOTES:
45B-1 MECH RM CONDENSING 1,999 1,920 1942 96% 160 NOTE 2 14.5 16 20 120 / 1 DIV. 26 8 8 LOCHINVAR FB-2001 1 - 3
INPUT
(MBH)
OUTPUT
(MBH)
GAS
(CFH)
MAX.
EFF.
EWT
(°F)
LWT
(°F)
FLOW MIN/MAX
(GPM)
PRESS.
LOSS (FT)
AMPS MOCP VOLT/PH DISC.
DIA.
(IN)
DIA.
(IN)
MANUFACTURER MODEL
MARK LOCATION TYPE
CAPACITY PRESS.
RATING
(PSI)
WATER ELECTRICAL DATA FLUE C.A. BASIS OF DESIGN
NOTES
BOILER SCHEDULE
1. CONTRATOR TO MEASURE AND MATCH EXISTING
NOTES:
45P-4 MECH. RM HOT WATER LOOP CENTRIFUGAL 199 - - - 155 - 20 - 460 / 3 CS DIV. 26 BELL & GOSSETT 2.5AC 1
45P-3 MECH. RM HOT WATER LOOP CENTRIFUGAL 199 - - - 155 - 20 - 460 / 3 CS DIV. 26 BELL & GOSSETT 2.5AC 1
45P-2 MECH. RM CHILLED WATER LOOP CENTRIFUGAL 152 - - - 60 - 5 - 460 / 3 CS DIV. 26 BELL & GOSSETT 2BD 1
45P-1 MECH. RM CHILLED WATER LOOP CENTRIFUGAL 152 - - - 60 - 5 - 460 / 3 CS DIV. 26 BELL & GOSSETT 2BD 1
02P-1 MECH. RM HOT WATER LOOP CENTRIFUGAL 38 140 180 145 45 61.8 1.5 3450 208 / 1 VARIABLE DIV. 26 BELL & GOSSETT 1.25AAB
HP
(WATTS)
RPM VOLT/PH
CONTROL
TYPE
DISC. BY MANUFACTURER MODEL
MARK LOCATION SERVES TYPE
FLOW
GPM
TEMP
OPER
To, ˚F
TEMP
MAX.
˚F
PRESS.
MAX.
PSIG
HEAD
FT WG
'@ To
MIN
EFF
MOTOR DATA BASIS OF DESIGN
NOTES
PUMP SCHEDULE
1. PROVIDE ALL WIRING, TRANSFORMERS AND DEVICES NECESSARY FOR COMPLETE INTEGRATION WITH BUILDING HVAC DDC CONTROL SYSTEM.
NOTES:
VAV-3.8 BUILDING 2 9 225 735 225 735 0.27 2 17.3 1 0.25 65 86.6 140 105.1 30 PRICE SDV 1
VAV-3.7 BUILDING 2 9 210 700 210 700 0.25 2 17 1 0.25 65 87.3 140 105.7 30 PRICE SDV 1
VAV-3.6 BUILDING 2 16 615 2040 615 2040 0.34 2 47.3 2.75 0.87 65 86.4 140 105.1 30 PRICE SDV 1
VAV-3.5 BUILDING 2 12 375 1240 375 1240 0.38 2 28.3 1.75 0.82 65 86 140 107.3 30 PRICE SDV 1
VAV-3.4 BUILDING 2 12 355 1180 355 1180 0.35 2 27.8 1.75 0.82 65 86.7 140 107.8 30 PRICE SDV 1
VAV-3.3 BUILDING 2 14 475 1580 475 1580 0.32 2 35.9 2 0.47 65 85.9 140 103.6 30 PRICE SDV 1
VAV-3.2 BUILDING 2 12 300 1000 300 1000 0.27 2 22.7 1.25 0.45 65 85.8 140 103.3 30 PRICE SDV 1
VAV-3.1 BUILDING 2 12 345 1140 345 1140 0.33 2 27.5 1.75 0.82 65 87.2 140 108.1 30 PRICE SDV 1
VAV-2.21 BUILDING 2 12 320 1060 320 1060 0.3 2 25.2 1.5 0.62 65 86.8 140 106.1 30 PRICE SDV 1
VAV-2.20 BUILDING 2 10 255 850 255 850 0.34 2 20 1.25 0.37 65 86.6 140 107.7 30 PRICE SDV 1
VAV-2.19 BUILDING 2 9 195 650 195 650 0.22 2 16.6 1 0.25 65 88.5 140 106.5 30 PRICE SDV 1
VAV-2.18 BUILDING 2 14 465 1540 465 1540 0.3 2 35.6 2 0.47 65 86.3 140 103.9 30 PRICE SDV 1
VAV-2.17 BUILDING 2 8 175 575 175 575 0.33 2 12.8 0.75 0.12 65 85.4 140 105.5 30 PRICE SDV 1
VAV-2.16 BUILDING 2 4 85 280 85 280 0.14 2 7.9 0.5 0.04 65 90.7 140 108.4 30 PRICE SDV 1
VAV-2.15 BUILDING 2 4 85 275 85 275 0.13 2 7.8 0.5 0.04 65 91 140 108.6 30 PRICE SDV 1
VAV-2.14 BUILDING 2 7 135 440 135 440 0.25 2 11.8 0.75 0.12 65 89.5 140 108.4 30 PRICE SDV 1
VAV-2.13 BUILDING 2 8 160 520 160 520 0.28 2 12.4 0.75 0.12 65 86.9 140 106.6 30 PRICE SDV 1
VAV-2.12 BUILDING 2 8 150 485 150 485 0.25 2 12.2 0.75 0.12 65 88 140 107.4 30 PRICE SDV 1
VAV-2.11 BUILDING 2 6 90 300 90 300 0.22 2 8.1 0.5 0.04 65 89.6 140 107.6 30 PRICE SDV 1
VAV-2.10 BUILDING 2 7 125 415 125 415 0.22 2 11.5 0.75 0.12 65 90.4 140 109.1 30 PRICE SDV 1
VAV-2.9 BUILDING 2 9 225 735 225 735 0.27 2 17.3 1 0.25 65 86.6 140 105.1 30 PRICE SDV 1
VAV-2.8 BUILDING 2 12 315 1035 315 1035 0.29 2 25 1.5 0.62 65 87.2 140 106.3 30 PRICE SDV 1
VAV-2.7 BUILDING 2 12 330 1090 330 1090 0.31 2 25.4 1.5 0.62 65 86.4 140 105.8 30 PRICE SDV 1
VAV-2.6 BUILDING 2 10 235 770 235 770 0.29 2 17.5 1 0.25 65 85.9 140 104.6 30 PRICE SDV 1
VAV-2.5 BUILDING 2 8 180 590 180 590 0.34 2 12.9 0.75 0.12 65 85.1 140 105.3 30 PRICE SDV 1
VAV-2.4 BUILDING 2 10 245 810 245 810 0.32 2 19.7 1.25 0.37 65 87.3 140 108.2 30 PRICE SDV 1
VAV-2.3 BUILDING 2 12 330 1085 330 1085 0.31 2 25.3 1.5 0.62 65 86.5 140 105.8 30 PRICE SDV 1
VAV-2.2 BUILDING 2 12 305 1015 305 1015 0.28 2 24.8 1.5 0.62 65 87.5 140 106.5 30 PRICE SDV 1
VAV-2.1 BUILDING 2 12 400 1320 400 1320 0.42 2 28.8 1.75 0.82 65 85.1 140 106.6 30 PRICE SDV 1
VAV-1.6 BUILDING 2 16 600 2000 600 2000 0.33 2 47.1 2.75 0.87 65 86.7 140 105.3 30 PRICE SDV 1
VAV-1.5 BUILDING 2 16 605 2010 605 2010 0.33 2 47.1 2.75 0.87 65 86.6 140 105.3 30 PRICE SDV 1
VAV-1.4 BUILDING 2 14 430 1415 430 1415 0.27 2 32.5 1.75 0.37 65 86.2 140 102.3 30 PRICE SDV 1
VAV-1.3 BUILDING 2 8 190 630 190 630 0.38 2 14.9 1 0.19 65 86.7 140 109.9 30 PRICE SDV 1
VAV-1.2 BUILDING 2 12 380 1255 380 1255 0.39 2 28.4 1.75 0.82 65 85.8 140 107.2 30 PRICE SDV 1
VAV-1.1 BUILDING 2 14 550 1830 550 1830 0.4 2 43.5 2.75 0.82 65 86.9 140 108 30 PRICE SDV 1
MIN MAX MIN MAX
MAX AIR PD
(IN WG)
# OF
ROWS
CAPACITY
(MBH)
FLOW
(GPM)
WPD
(FT)
EAT
(°F)
LAT
(°F)
EWT
(°F)
LWT
(°F)
MANUFACTURER MODEL
MARK LOCATION
AIR INLET
SIZE (IN)
COOLING
AIRFLOW (CFM)
HEATING
AIRFLOW (CFM)
REHEAT COIL MAX
DISCHARGE
NC
BASIS OF DESIGN
NOTES
VAV TERMINAL BOXES WITH HOT WATER REHEAT SCHEDULE
MAR 2020 B-3 DESIGN SUBMITTAL
4. 2 INCH MERV 8 FILTER
3. LOW AMBIENT OPERATION KIT
2. WALL MOUNTED THERMOSTAT.
1. DISCONNECT SWITCH
NOTES:
72WMU-2 800 0.3 23.6 18.0 R410A 9.0 46 50 208 / 1 8 310 BARD W24A2-A08 1 - 4
72WMU-1 800 0.3 23.6 18.0 R410A 9.0 46 50 208 / 1 8 310 BARD W24A2-A08 1 - 4
(MBH) (MBH)
TOTAL SENSIBLE
MCA MOCP
VOLTAGE /
PHASE
ELEC. HEAT
(kW)
MANUFACTURER MODEL
MARK
NOMINAL
CFM
ESP
(IN WC)
COOLING CAPACITY
REFRIG.
MIN
EER
ELECTRICAL DATA
WEIGHT
(LBS)
BASIS OF DESIGN
NOTES
SINGLE PACKAGED VERTICAL AIR CONDITIONER SCHEDULE
1. PROVIDE BLADDER RATED FOR 215˚F AND TANK/SYSTEM MAWP = 125 PSIG
NOTES:
02ET-1 MECH. RM HW HEATING 45 140 40 40 10 12 9 3 12 x 22 AMTROL EXTROL AX-15-V 1
MAX MIN MAX MIN
MANUFACTURER MODEL
MARK LOCATION
SYSTEM
SERVED
SYSTEM
VOLUME
GAL
TEMP RANGE
°F
PRESS RANGE
PSI
BLADDER
PRESS
PSI
TANK
VOLUME
GAL
ACCEPTANCE
VOLUME
GAL
TANK SIZE
DIA x L
IN
BASIS OF DESIGN
NOTES
EXPANSION TANK SCHEDULE
NOTE: "EQUAL TO" MANUFACTURERS CAN BE SUBMITTED FOR ALL UNITS DESCRIBED IN THE
SCHEDULE AS LONG AS THEY MEET OR EXCEED THE PERFORMANCE AND SPECIFICATIONS
File details come from the government source that posted it. Updated .