10 51 13 FL - Metal Lockers.pdf
PDF 91 KB Posted
- Attached to
- REPAIR MAINTENANCE HANGAR, BLDG 25
- Solicitation number
- W50S7L23B0002
- Issued by
-
Department of the Army National Guard
About this file
This solicitation is for repair and maintenance services at Building 25 of the Montana Air National Guard facility. The required work includes replacement of the lower roof membrane, asphalt and drainage repair, removal of unused floor rails, installation of an overhead crane and door hardware upgrades, application of a new floor coating, and mechanical and electrical system repairs. The contract value is between $1-5 million and has a performance period of 120 calendar days.
This opportunity is set aside exclusively for small businesses with a NAICS code of 236220 and size standard of $45 million. A pre-bid conference will be held on June 13th followed by a site visit. Questions are due by June 23rd and bids are due on July 7th. The solicitation can only be obtained through SAM.gov and the prime contractor is restricted to paying no more than 85% of the contract amount to similarly situated subcontractors.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
120th AIRLIFT WING PROJECT JKSE 172220
MONTANA AIR NATIONAL GUARD REPAIR MAINTENANCE HANGAR, BLDG 25
GREAT FALLS, MONTANA TYPE B-3 SUBMITTAL
METAL LOCKERS 10 51 13 - 1
SECTION 10 51 13 - METAL LOCKERS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Welded athletic lockers.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of metal locker and bench.
B. Shop Drawings: For metal lockers.
1. Include plans, elevations, sections, and attachment details.
2. Show locker trim and accessories.
3. Include locker identification system and numbering sequence.
C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.
D. Samples for Verification: For the following products, in manufacturer's standard size:
1. Lockers and equipment.
2. Locker benches.
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer.
B. Sample Warranty: For special warranty.
METAL LOCKERS 10 51 13 - 2
1.5 CLOSEOUT SUBMITTALS
A. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals.
1.6 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
1. The following metal locker hardware items equal to 10 percent of amount installed for each type and finish installed, but no fewer than five units:
a. Blank identification plates.
b. Hooks.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation.
1.8 FIELD CONDITIONS
A. Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication.
1.9 COORDINATION
A. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and installed as indicated.
1.10 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures.
b. Faulty operation of latches and other door hardware.
2. Damage from deliberate destruction and vandalism is excluded.
3. Warranty Period for Welded Metal Lockers: Lifetime from date of Substantial
Completion.
METAL LOCKERS 10 51 13 - 3
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations: Obtain metal lockers, locker benches, and accessories from single source from single locker manufacturer.
2.2 WELDED ATHLETIC LOCKERS
A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
1. Art Metal Products.
2. ASI Storage Solutions.
3. Lyon Workspace Products, LLC.
4. Olympus Lockers and Storage Products, Inc. (Basis of Design).
a. Hercules heavy-duty Athletic, all welded.
5. Superior Lockers by List Industries.
B. Perforated Doors: One piece; fabricated from not less than 14 gauge nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges.
1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches (381 mm) wide; welded to inner face of doors.
C. Body: Assembled by welding body components together. Fabricate from unperforated steel sheet with thicknesses as follows:
1. Tops and Bottoms: 16 gauge minimum nominal thickness, with single bend at edges.
2. Backs: 16 gauge minimum nominal thickness.
3. Shelves: 16 gauge minimum nominal thickness, with double bend at front and single bend at sides and back.
D. Unperforated Sides: Fabricated from 16 gauge nominal-thickness steel sheet.
E. Frames: Channel formed; fabricated from 16 gauge minimum nominal-thickness steel sheet lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.
F. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed;
fabricated to swing 180 degrees.
METAL LOCKERS 10 51 13 - 4
1. Continuous Hinges: Manufacturer's standard, steel; side or top mounted as required by locker configuration.
G. Projecting Turn-Handle and Latch: Steel handle welded to manufacturer's standard, three-point, cremone-type latching mechanism consisting of steel rods or bars that engage locker frame at top and bottom of door, and center latch that engages strike jamb; with steel padlock loop.
H. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch (9 mm) high.
I. Hooks: Manufacturer's standard ball-pointed, aluminum or steel; zinc plated.
J. Coat Rods: Manufacturer's standard.
K. Continuous Zee Base: 4 inches (102 mm) high; fabricated from 0.075-inch (1.90-mm) nominal-thickness steel sheet.
L. Recess Trim: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.
M. Filler Panels: Fabricated from 0.048-inch (1.21-mm) nominal-thickness steel sheet.
N. Boxed End Panels: Fabricated from 0.060-inch (1.52-mm) nominal-thickness steel sheet.
O. Finished End Panels: Fabricated from 0.024-inch (0.61-mm) nominal-thickness steel sheet to cover unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers.
P. Materials:
1. Cold-Rolled Steel Sheet: ASTM A1008/A1008M, Commercial Steel (CS), Type B, suitable for exposed applications.
2. Metallic-Coated Steel Sheet: ASTM A653/A653M, Commercial Steel (CS), Type B; with
A60 (ZF180) zinc-iron, alloy (galvannealed) coating designation.
3. Expanded Metal: ASTM F1267, Type II (flattened), Class I (uncoated), 3/4-inch (19-mm) steel mesh, with at least 70 percent open area.
4.
Q. Finish: Baked enamel or powder coat.
1. Color: As selected by Architect from manufacturer's full range.
2.3 LOCKER BENCHES
A. Provide bench units with overall assembly height of 17-1/2 inches (445 mm).
B. Bench Tops: Manufacturer's standard one-piece units, with rounded corners and edges.
1. Size: Minimum 9-1/2 inches wide by 1-1/4 inches thick (241 mm wide by 32 mm thick).
METAL LOCKERS 10 51 13 - 5
2. Laminated clear hardwood with one coat of clear sealer on all surfaces and one coat of clear lacquer on top and sides.
C. Fixed-Bench Pedestals: Manufacturer's standard supports, with predrilled fastener holes for attaching bench top and anchoring to floor, complete with fasteners and anchors, and as follows:
1. Tubular Steel:
a. 1-1/2-inch- (38-mm-) minimum diameter steel tubing threaded on both ends, with standard pipe flange at top and bell-shaped cast-iron base; with baked-enamel or powder-coat finish; anchored with exposed fasteners.
b. Color: Match metal lockers.
D. Materials:
1. Stainless Steel Plate, Sheet, and Strip: ASTM A240/A240M or ASTM A666, Type 304.
2. Steel Tube: ASTM A500/A500M, cold rolled.
2.4 FABRICATION
A. Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs.
1. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless otherwise indicated.
2. Provide fasteners, filler plates, supports, clips, and closures as required for complete installation.
B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments.
C. Equipment: Provide each locker with an identification plate and the following equipment:
1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks.
2. Coat Rods: In lieu of ceiling hook for metal lockers 18 inches (457 mm) deep or more.
D. Welded Construction: Factory preassemble metal lockers by welding all joints, seams, and connections; with no bolts, nuts, screws, or rivets used in assembly of main locker groups.
Factory weld main locker groups into one-piece structures. Grind exposed welds smooth and flush.
E. Continuous Zee Base: Fabricated in lengths as long as practical to enclose base and base ends;
finished to match lockers.
F. Recess Trim: Fabricated with minimum 2-1/2-inch (64-mm) face width and in lengths as long as practical; finished to match lockers.
METAL LOCKERS 10 51 13 - 6
G. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel.
H. Boxed End Panels: Fabricated with 1-inch- (25-mm-) wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers.
1. Provide one-piece panels for double-row (back-to-back) locker ends.
I. Finished End Panels: Fabricated to conceal unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers.
1. Provide one-piece panels for double-row (back-to-back) locker ends.
J. Center Dividers: Full-depth, vertical partitions between bottom and shelf; finished to match lockers.
2.5 ACCESSORIES
A. Fasteners: Zinc- or nickel-plated steel, slotless-type, exposed bolt heads; with self-locking nuts or lock washers for nuts on moving parts.
B. Base: Provided by Metal Locker Manufacturer. Galvannealed 14 gauge steel, 4” zee style base, manufacturer’s standard. Color to match lockers.
C. Anchors: Material, type, and size required for secure anchorage to each substrate.
1. Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior walls, and elsewhere as indicated, for corrosion resistance.
2. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine walls and floors or support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Install lockers level, plumb, and true; shim as required, using concealed shims.
METAL LOCKERS 10 51 13 - 7
1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than 36 inches (910 mm) o.c. Using concealed fasteners, install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion.
2. Anchor single rows of metal lockers to walls near top and bottom of lockers of lockers and to floor.
3. Anchor back-to-back metal lockers to floor.
B. Welded Lockers: Connect groups together with manufacturer's standard fasteners, with no exposed fasteners on face frames.
C. Equipment:
1. Attach hooks with at least two fasteners.
2. Attach door locks on doors using security-type fasteners.
3. Identification Plates: Identify metal lockers with identification indicated on Drawings.
a. Attach plates to each locker door, near top, centered, with at least two aluminum rivets.
b. Attach plates to upper shelf of each open-front metal locker, centered, with a least two aluminum rivets.
D. Trim: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates.
1. Attach recess trim to recessed metal lockers with concealed clips.
2. Attach filler panels with concealed fasteners. Locate filler panels where indicated on
Drawings.
3. Attach sloping-top units to metal lockers, with closures at exposed ends.
4. Attach boxed end panels using concealed fasteners to conceal exposed ends of nonrecessed metal lockers.
5. Attach finished end panels using fasteners only at perimeter to conceal exposed ends of nonrecessed metal lockers.
E. Fixed Benches: Provide no fewer than two pedestals for each bench, uniformly spaced not more than 72 inches (1830 mm) apart. Securely fasten tops of pedestals to undersides of bench tops, and anchor bases to floor.
3.3 ADJUSTING
A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding.
3.4 PROTECTION
A. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction.
METAL LOCKERS 10 51 13 - 8
B. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer.
END OF SECTION 10 51 13