The document is a detailed equipment list for a WARISC Alarm System Panel installation, specifying components for two separate system locations: a SCIF IDS System and a PG&E Room Collateral IDS System. The equipment list includes multiple technical components from DMP and ELK PRODUCTS, such as control panels, battery harnesses, touchscreen keypads with proximity readers, zone expanders, antennas, and various door contacts and sensors.

The related federal contract opportunity (Solicitation Number W15QKN25R11VN) is for MIRC ICS/ACS Maintenance, issued by Army Contracting Command - New Jersey. The solicitation seeks maintenance and break-fix support for Intrusion Detection Systems (IDS) and Access Control Systems (ACS) at multiple locations, including ARISCs, MIRC Headquarters, and monitoring stations. The solicitation is scheduled for response by 31 March 2025 at 10:00 EST, with the contract award date and amount currently to be determined. The procurement will cover maintenance services for the US Army Military Intelligence Readiness Command across various locations in the United States.

View the file

Other files

File Type Posted
NCARISC Fort Sheridan IL - DMP.docx DOCX document
MIRC HQ Fort Belvoir VA - DMP.docx DOCX document
WARISC Phoneix AZ - DMP.docx DOCX document
NEARISC Fort Meade MD - DMP.docx DOCX document
SEARISC Orlando FL - DMP.docx DOCX document
SWARISC San Antonio - DMP.docx DOCX document
NEAEISC Fort Devens MA - DMP.docx DOCX document
Fort Dix NJ - DMP.docx DOCX document
Forest Park GA site - DMP.docx DOCX document
MIRC ICS ACS Questions and Answers.docx DOCX document
A002 Preventive Maintenance Schedule.pdf PDF
25R11VN Solicitation MIRC IDS ACS Maintenance Final.docx DOCX document
MIRC IDS-ACS Maintenance PWS 5March.docx DOCX document
A004 Corrective maintenance routine or emergency service report.pdf PDF
A003 Parts.pdf PDF
A001 Quality Control Plan.pdf PDF
MIRC IDS-ACS Maintenance QASP.docx DOCX document
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WARISC Alarm System Panel Locations

SCIF IDS System - RM115

Batteries
2
BATTERY LEAD ACID 12V-8.0AH

(ELK PRODUCTS, INC. – 1280)

Power Supply - Alarm Devices
1
100 VA Wire-In Transformer

(DMP – 324P)

Panel Accessory 1
1
Battery Harness with Panel Termnal connections

(DMP – 318T)

Keypad
2
GRAPHIC TOUCHSCREEN KEYPAD W/PROX READER & 4 ZONES

(DMP – 7872-W)

Control Panel
4
Attack Enclosure 16Gauge

(DMP – 350A-G)

Control Panel
4
Conduit Backbox

(DMP – 350C-G)

Zone Expander
4
ZONE EXPANSION EXP, 16 POINT, PCB ONLY

(DMP – 714-16 PCB)

Zone Expander
1
MOUNTING PLATE FOR THE LARGE ENCLOSURE

(DMP – 354A-G)

Communicator #1
1
3DB MEG ANTENNA

(DMP – 388-3)

Communicator #1
1
SMA TO N CABLE, 50FT, LMR195COAX CABLE

(DMP – 387-50)

Other
1
Materials: Conduit for Cellular Cable provided by S101

COLLATERAL IDS System - PG&E ROOM

Control Panel
1
Existing or Customer Supplied
Batteries
2
BATTERY LEAD ACID 12V-8.0AH

(ELK PRODUCTS, INC. – 1280)

Power Supply - Alarm Devices
1
100 VA Wire-In Transformer

(DMP – 324P)

Panel Accessory 1
1
Battery Harness with Panel Termnal connections

(DMP – 318T)

Keypad
2
GRAPHIC TOUCHSCREEN KEYPAD W/PROX READER & 4 ZONES

(DMP – 7872-W)

Control Panel
2
Attack Enclosure 16Gauge

(DMP – 350A-G)

Control Panel
3
Conduit Backbox

(DMP – 350C-G)

Zone Expander
3
ZONE EXPANSION EXP, 16 POINT, PCB ONLY

(DMP – 714-16 PCB)

Zone Expander
1
MOUNTING PLATE FOR THE LARGE ENCLOSURE

(DMP – 354A-G)

Communicator #1
1
3DB MEG ANTENNA

(DMP – 388-3)

Communicator #1
1
SMA TO N CABLE, 50FT, LMR195COAX CABLE

(DMP – 387-50)

Other
1
Extra Labor: Install Existing DMP Control Panel provided by s101
Other
1
Materials: Conduit for Cellular Cable provided by S101

Doors

Existing HSS - New Wire - RM 104 N DBL DR

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire Alarm and Tamper Circuits provided by S101

Existing HSS - New Wire - SCIF ENTRY

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire Alarm and Tamper Circuits provided by S101

Existing HSS - New Wire - RM 104 S DR

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire Alarm and Tamper Circuits provided by S101

Existing HSS - New Wire - EAST EXTERIOR DBL DR

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire Alarm and Tamper Circuits provided by S101

SIPR Cabinet Contact Clip on tamper switch

(DMP – 307)

Existing HSS - New Wire - East Exterior

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire alarm and tamper circuit provided by S101

Existing HSS - New Wire - Maintenance

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire alarm and tamper circuit provided by S101

Existing HSS - New Wire - Storage (GYM)

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire alarm and tamper circuit provided by S101

Existing HSS - New Wire - Main Entry Vestibule

Contact
1
Existing or Customer Supplied
Other
1
Extra Labor: Wire alarm and tamper circuit provided by S101

HSS - Atrium S Contact

DUAL ALARM CONTACT,CLOSED LOOP

(MAGNASPHERE – HSS-L2D-000)

HSS - Atrium W Contact

DUAL ALARM CONTACT,CLOSED LOOP

(MAGNASPHERE – HSS-L2D-000)

Motion Sensors