NCARISC Fort Sheridan IL - DMP.docx
DOCX document 21 KB Posted
- Attached to
- MIRC ICS/ACS Maintenance
- Solicitation number
- W15QKN25R11VN
About this file
The document appears to be a detailed equipment list for an Intrusion Detection System (IDS) and Access Control System (ACS) installation at NCARISC, Fort Sheridan, IL. The equipment list specifies multiple security components including an UL 2050 Certified Alarm Panel (Model XR550DEAG), motion detectors (Bosch models DS9360 and SC-BDL2-W12G), high security door contacts, touchscreen keypads, cellular modem interfaces, network interfaces, tamper switches, batteries, transformers, zone expansion units, and sirens. All equipment is specified with precise quantities and model numbers, with the country of origin noted as US.
The related federal contract opportunity is a solicitation (Number W15QKN25R11VN) for ICS/ACS Maintenance issued by Army Contracting Command - New Jersey. The solicitation seeks maintenance and break-fix support for Intrusion Detection and Access Control Systems at multiple locations, including ARISCs, MIRC HQ, and monitoring stations. Key dates include a solicitation release on March 24, 2025, with responses due by March 31, 2025, at 10:00 EST. The contract award details are currently to be determined (TBD), with performance locations spanning various sites throughout the United States. The primary point of contact is William Campbell, and the solicitation falls under Product/Service Code 6350.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MIRC HQ Fort Belvoir VA - DMP.docx | DOCX document | |
| WARISC.docx | DOCX document | |
| Fort Dix NJ - DMP.docx | DOCX document | |
| Forest Park GA site - DMP.docx | DOCX document | |
| SWARISC San Antonio - DMP.docx | DOCX document | |
| NEAEISC Fort Devens MA - DMP.docx | DOCX document | |
| SEARISC Orlando FL - DMP.docx | DOCX document | |
| WARISC Phoneix AZ - DMP.docx | DOCX document | |
| NEARISC Fort Meade MD - DMP.docx | DOCX document | |
| MIRC ICS ACS Questions and Answers.docx | DOCX document | |
| MIRC IDS-ACS Maintenance PWS 5March.docx | DOCX document | |
| A001 Quality Control Plan.pdf | ||
| MIRC IDS-ACS Maintenance QASP.docx | DOCX document | |
| A003 Parts.pdf | ||
| 25R11VN Solicitation MIRC IDS ACS Maintenance Final.docx | DOCX document | |
| A002 Preventive Maintenance Schedule.pdf | ||
| A004 Corrective maintenance routine or emergency service report.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE:
NCARISC, FORT SHERIDAN, IL
Equipment required:
Model
Quantity
Alarm Panel UL 2050 Certified ICD 705 with Encryption
XR550DEAG DMP Kit Controller/Dialer/Network Country of origin: US
Downstream Attack - Resistant Enclosure
| 350-A-G |
| 1 |
| Motion detector PIR 360 deg |
| DS9360 Bosch |
| 3 |
| Motion detector 90 deg |
| SC-BDL2-W12G Bosch |
| 5 |
| High Security Door Contact Switch |
| HSS-L2D-000 Magnasphere |
| 10 |
| High Security Touchscreen Keypad |
| 7872-W |
| 4 |
| Cellular Modem Interface |
| B444-V / B444-A |
| 1 |
| Network Interface |
| Included in kit |
| 1 |
| Tamper Switches |
| 307 |
| 3 |
| Battery 12 VDC 18AH Lead Acid |
| 366/2 One pair per /Panel |
| 1 |
| Battery Harness |
| 318T |
| 1 |
| Plug in Transformer |
| 324P Wire In |
| 1 |
| Zone Expansion unit |
| 714-16L-G DMP |
16 Zone expander in 350 Enclosure
| siren interior |
| D116 this is indoor |
| 1 |
| Motion detector 90 deg |
| SC-BDL2-W12G Bosch |
| 5 |
Siren D116
File details come from the government source that posted it. Updated .