SWARISC San Antonio - DMP.docx
DOCX document 20 KB Posted
- Attached to
- MIRC ICS/ACS Maintenance
- Solicitation number
- W15QKN25R11VN
About this file
The document is a detailed equipment list for the SWARISC San Antonio site related to a Department of the Army solicitation for ICS/ACS Maintenance. The equipment list specifies multiple security system components including 3 Alarm Panels (UL 2050 Certified ICD 705 with Encryption), 3 Downstream Attack-Resistant Enclosures, 14 motion detectors (both 360 and 90 degree models), 21 High Security Door Contact Switches, 6 High Security Touchscreen Keypads, 3 Cellular Modem Interfaces, and supporting infrastructure like batteries, transformers, and expansion units.
The associated federal contract opportunity (Solicitation Number W15QKN25R11VN) is for maintenance and break-fix support for Intrusion Detection Systems (IDS) and Access Control Systems (ACS) at Army Regional Intelligence Support Centers (ARISCs), MIRC Headquarters, and monitoring stations. The solicitation is issued by Army Contracting Command - New Jersey, with a response closing date of 31 March 2025 at 10:00 EST. The contract award details, including dollar amount and specific contractor, are currently to be determined (TBD), with performance locations spanning various sites throughout the United States.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NCARISC Fort Sheridan IL - DMP.docx | DOCX document | |
| MIRC HQ Fort Belvoir VA - DMP.docx | DOCX document | |
| WARISC Phoneix AZ - DMP.docx | DOCX document | |
| NEARISC Fort Meade MD - DMP.docx | DOCX document | |
| SEARISC Orlando FL - DMP.docx | DOCX document | |
| WARISC.docx | DOCX document | |
| NEAEISC Fort Devens MA - DMP.docx | DOCX document | |
| Fort Dix NJ - DMP.docx | DOCX document | |
| Forest Park GA site - DMP.docx | DOCX document | |
| MIRC ICS ACS Questions and Answers.docx | DOCX document | |
| A002 Preventive Maintenance Schedule.pdf | ||
| 25R11VN Solicitation MIRC IDS ACS Maintenance Final.docx | DOCX document | |
| MIRC IDS-ACS Maintenance PWS 5March.docx | DOCX document | |
| A004 Corrective maintenance routine or emergency service report.pdf | ||
| A003 Parts.pdf | ||
| A001 Quality Control Plan.pdf | ||
| MIRC IDS-ACS Maintenance QASP.docx | DOCX document |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE:
SWARISC, SAN ANTONIO
Equipment required:
Model
Quantity
Alarm Panel UL 2050 Certified ICD 705 with Encryption
XR550DEAG DMP Kit Controller/Dialer/Network Country of origin: US
Downstream Attack - Resistant Enclosure
350-A-G
| Motion detector PIR 360 deg |
| DS9360 Bosch |
| 6 |
| Motion detector 90 deg |
| SC-BDL2-W12G Bosch |
| 8 |
| High Security Door Contact Switch |
| HSS-L2D-000 Bosch |
| 21 |
| High Security Touchscreen Keypad |
| 7872-W |
| 6 |
| Cellular Modem Interface |
| 263LTE-V/381-2 |
| 3 |
| Network Interface |
| Included in kit |
| 3 |
| Tamper Switches |
| 307 |
| 9 |
| Battery 12 VDC 18AH Lead Acid |
| D1218 need two for panel not in kit |
| 6 |
| Battery Harness |
| 318T |
| 3 |
| Plug in Transformer |
| 324P Wire-In |
| 3 |
| Zone Expansion unit |
| 714-16L-G |
| 3 |
| Motion detector 90 deg |
| SC-BDL2-W12G Bosch |
| 8 |
File details come from the government source that posted it. Updated .