MIRC HQ Fort Belvoir VA - DMP.docx

DOCX document 20 KB Posted

Attached to
MIRC ICS/ACS Maintenance
Solicitation number
W15QKN25R11VN
Issued by

About this file

This document is a detailed equipment list for a security system installation at MIRC HQ Fort Belvoir, VA. The proposed equipment includes a UL 2050 Certified ICD 705 Alarm Panel with Encryption (XR550DEAG DMP Kit), a downstream attack-resistant enclosure, 12 motion detectors, 4 high-security door contact switches, 4 high-security touchscreen keypads, a cellular modem interface, network interface, tamper switches, batteries, and zone expansion units. All equipment is specified with precise model numbers and quantities, with the country of origin noted as US.

The related federal contract opportunity (Solicitation Number W15QKN25R11VN) is for MIRC ICS/ACS Maintenance, issued by Army Contracting Command - New Jersey. The solicitation seeks maintenance and break-fix support for Intrusion Detection Systems (IDS) and Access Control Systems (ACS) at various locations, including MIRC HQ and monitoring stations. The solicitation is scheduled for response by 31 March 2025 at 10:00 EST, with the contract award date and dollar amount currently to be determined. The primary point of contact is William Campbell, and the service will cover various locations throughout the United States.

View the file

Other files

File Type Posted
WARISC.docx DOCX document
Fort Dix NJ - DMP.docx DOCX document
Forest Park GA site - DMP.docx DOCX document
SWARISC San Antonio - DMP.docx DOCX document
NEAEISC Fort Devens MA - DMP.docx DOCX document
NCARISC Fort Sheridan IL - DMP.docx DOCX document
SEARISC Orlando FL - DMP.docx DOCX document
WARISC Phoneix AZ - DMP.docx DOCX document
NEARISC Fort Meade MD - DMP.docx DOCX document
MIRC ICS ACS Questions and Answers.docx DOCX document
MIRC IDS-ACS Maintenance PWS 5March.docx DOCX document
A001 Quality Control Plan.pdf PDF
MIRC IDS-ACS Maintenance QASP.docx DOCX document
A003 Parts.pdf PDF
25R11VN Solicitation MIRC IDS ACS Maintenance Final.docx DOCX document
A002 Preventive Maintenance Schedule.pdf PDF
A004 Corrective maintenance routine or emergency service report.pdf PDF
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SITE:

MIRC HQ FORT BELVOIR, VA

Equipment required:

Model

Quantity

Alarm Panel UL 2050 Certified ICD 705 with Encryption
XR550DEAG DMP Kit Controller/Dialer/Network

Country of origin: US

Downstream Attack - Resistant Enclosure

350-A-G
1
Motion detector PIR 360 deg
DS9360 Bosch
12
High Security Door Contact Switch
HSS-L2D-000 Magnasphere
4
High Security Touchscreen Keypad
7872-W
4
Cellular Modem Interface
263LTE-V/381-2
1
Network Interface
Included in kit
1
Tamper Switches
307
3
Battery 12 VDC 18AH Lead Acid
366/2 One pair per/Panel
1
Battery Harness
318T
1
Plug in Transformer
324P Wire-In
1
Zone Expansion unit
714-16L-G DMP

16 Zone expanders in 350 Enclosure