MIRC HQ Fort Belvoir VA - DMP.docx
DOCX document 20 KB Posted
- Attached to
- MIRC ICS/ACS Maintenance
- Solicitation number
- W15QKN25R11VN
About this file
This document is a detailed equipment list for a security system installation at MIRC HQ Fort Belvoir, VA. The proposed equipment includes a UL 2050 Certified ICD 705 Alarm Panel with Encryption (XR550DEAG DMP Kit), a downstream attack-resistant enclosure, 12 motion detectors, 4 high-security door contact switches, 4 high-security touchscreen keypads, a cellular modem interface, network interface, tamper switches, batteries, and zone expansion units. All equipment is specified with precise model numbers and quantities, with the country of origin noted as US.
The related federal contract opportunity (Solicitation Number W15QKN25R11VN) is for MIRC ICS/ACS Maintenance, issued by Army Contracting Command - New Jersey. The solicitation seeks maintenance and break-fix support for Intrusion Detection Systems (IDS) and Access Control Systems (ACS) at various locations, including MIRC HQ and monitoring stations. The solicitation is scheduled for response by 31 March 2025 at 10:00 EST, with the contract award date and dollar amount currently to be determined. The primary point of contact is William Campbell, and the service will cover various locations throughout the United States.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| WARISC.docx | DOCX document | |
| Fort Dix NJ - DMP.docx | DOCX document | |
| Forest Park GA site - DMP.docx | DOCX document | |
| SWARISC San Antonio - DMP.docx | DOCX document | |
| NEAEISC Fort Devens MA - DMP.docx | DOCX document | |
| NCARISC Fort Sheridan IL - DMP.docx | DOCX document | |
| SEARISC Orlando FL - DMP.docx | DOCX document | |
| WARISC Phoneix AZ - DMP.docx | DOCX document | |
| NEARISC Fort Meade MD - DMP.docx | DOCX document | |
| MIRC ICS ACS Questions and Answers.docx | DOCX document | |
| MIRC IDS-ACS Maintenance PWS 5March.docx | DOCX document | |
| A001 Quality Control Plan.pdf | ||
| MIRC IDS-ACS Maintenance QASP.docx | DOCX document | |
| A003 Parts.pdf | ||
| 25R11VN Solicitation MIRC IDS ACS Maintenance Final.docx | DOCX document | |
| A002 Preventive Maintenance Schedule.pdf | ||
| A004 Corrective maintenance routine or emergency service report.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE:
MIRC HQ FORT BELVOIR, VA
Equipment required:
Model
Quantity
| Alarm Panel UL 2050 Certified ICD 705 with Encryption |
| XR550DEAG DMP Kit Controller/Dialer/Network |
Country of origin: US
Downstream Attack - Resistant Enclosure
| 350-A-G |
| 1 |
| Motion detector PIR 360 deg |
| DS9360 Bosch |
| 12 |
| High Security Door Contact Switch |
| HSS-L2D-000 Magnasphere |
| 4 |
| High Security Touchscreen Keypad |
| 7872-W |
| 4 |
| Cellular Modem Interface |
| 263LTE-V/381-2 |
| 1 |
| Network Interface |
| Included in kit |
| 1 |
| Tamper Switches |
| 307 |
| 3 |
| Battery 12 VDC 18AH Lead Acid |
| 366/2 One pair per/Panel |
| 1 |
| Battery Harness |
| 318T |
| 1 |
| Plug in Transformer |
| 324P Wire-In |
| 1 |
| Zone Expansion unit |
| 714-16L-G DMP |
16 Zone expanders in 350 Enclosure
File details come from the government source that posted it. Updated .