This statement of work outlines testing requirements for the Receiver Radio Firing Device, Nonelectric Blasting Cap Actuating M17A1 and the Trainer, Receiver, Radio Firing Device, Non-explosive M85A1. The document specifies various environmental condition tests including cold and hot storage temperature testing, transportation and transit drop testing, cold and hot operating temperature testing, loose cargo testing, and immersion testing for the M17A1. It also defines performance requirement criteria for the receivers to accept programming from transmitters, receive test commands, notify of improper arming sequences, have a minimum five minute safe separation time, and not output before or on incorrect codes after the safe separation time. The receivers must also successfully initiate firing leads. This testing is applicable to first article and lot acceptance testing configurations.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
Remote Activation Munition System (RAMS) M17A1 Receiver & M85A1 Trainer Receiver
Figure 1: FAT Testing Matrix
Environmental Condition Specification Configuration Reference Cold Storage Temperature
-50° F (+0/-5° F) Packaged in its PA108 container
MIL-STD-810H, Procedure I, Operational, Method 502.7
Hot Storage Temperature +160° F (+5/-0° F) Packaged in its PA108 container
MIL-STD-810H, Procedure I, Operational, Method 501.7
Transportation Vibration (Secured Cargo)
-50° F (+0/-5° F) and +160° F (+5/-0° F)
Packaged in its PA108 container
MIL-STD 810H, Method 514.8, ANNEX C, Category 4 - Truck/Trailer - Secured Cargo, (Two Wheeled Trailer, Table 514.8C-III and Composite Wheeled Vehicle, Table 514.8C-V)
Transit Drop (7 Foot) -50° F (+0/-5° F) and +160° F (+5/-0° F)
Packaged in its PA108 container
7 Foot Drop, IAW ITOP 4-2-602
Cold Operating Temperature
-25° F (+0/-5° F) Bare MIL-STD-810H, Procedure II, Operational, Method 502.7
Hot Operating Temperature
+135° F (+5/-0° F) Bare MIL-STD-810H, Procedure II, Operational, Method 501.7
Loose Cargo -25° F (+0/-5° F) and +135° F (+5/-0° F)
Bare in Rucksack/Pack ITOP 4-2-602, Ground Platform Shock/Vibration Levels, Rough Handling Tests, Appendix B
Transit Drop (4 Foot) -25° F (+0/-5° F) and +135° F (+5/-0° F)
Bare ITOP 4-2-602, Four (4) Foot drop on Two (2) inches of plywood
Immersion Ambient (73° F ±10° F)
Bare (*M17A1 only) Immersed in Sixty Six (66) Feet of Salt Water for 30 minutes
Performance Requirement Criteria Configuration Applicability Program Receiver Accepts program from Tx Receiver FAT/LAT Operational Test Receives test command from Tx Receiver FAT/LAT
Arming Error Notify of improper arming sequence
Receiver FAT/LAT
Proper Arming At least Five Minute Safe Separation Time
Receiver FAT/LAT
No-Go Function Test No Output before SST, on wrong code after SST
Receiver w/ Lead FAT/LAT
Fire/Output Lead Initiation Receiver w/ Lead FAT/LAT
Performance Requirement Criteria Configuration Applicability Program Receiver Accepts program from Tx Receiver FAT/LAT Operational Test Receives test command from Tx Receiver FAT/LAT
Arming Error Notify of improper arming sequence
Receiver FAT/LAT
Proper Arming At least Five Minute Safe Separation Time
Receiver FAT/LAT
No-Go Function Test No Output before SST, on wrong code after SST
Receiver w/ Lead FAT/LAT
Fire/Output Lead Initiation Receiver w/ Lead FAT/LAT
File details come from the government source that posted it. Updated .