About this file

This statement of work outlines testing requirements for the Receiver Radio Firing Device, Nonelectric Blasting Cap Actuating M17A1 and the Trainer, Receiver, Radio Firing Device, Non-explosive M85A1. The document specifies various environmental condition tests including cold and hot storage temperature testing, transportation and transit drop testing, cold and hot operating temperature testing, loose cargo testing, and immersion testing for the M17A1. It also defines performance requirement criteria for the receivers to accept programming from transmitters, receive test commands, notify of improper arming sequences, have a minimum five minute safe separation time, and not output before or on incorrect codes after the safe separation time. The receivers must also successfully initiate firing leads. This testing is applicable to first article and lot acceptance testing configurations.

View the file

Other files for this federal contract opportunity

Other files attached to M17A1 RAMS, newest first.
File Type Posted
W15QKN20R0021-0005.pdf PDF
Attachment 0025 Qustions and Government Responses.pdf PDF
W15QKN20R0021_0004.pdf PDF
W15QKN-20-R-0021_0004.pdf PDF
W15QKN-20-R-0021_0003.pdf PDF
W15QKN-20-R-0021-0002.pdf PDF
Updated Attachment 0024 Questions and Answers 13MAR2020.docx DOCX document
W15QKN-20-R-0021-0001.pdf PDF
Attachment 0024 Questions and Answers.docx DOCX document
Attachment 0023 Dwg 12999545.pdf PDF
UPDATED Attachment 0022 GOVERNMENT FURNISHED PROPERTY LIST.xlsx XLSX spreadsheet
Attachment 0006 Non-Disclosure Agreement RAMS Update 11Feb2020.doc DOC document
W15QKN-20-R-0021.pdf PDF
Attachment 0006 Non-Disclosure Agreement RAMS.doc DOC document
Attachment 0007 Disclosure of Lobbying Activities.pdf PDF
Attachment 0003 Additional Solicitation and Contract Requirements.pdf PDF
Exhibit A - DD Form 1423 CDRLs.pdf PDF
Attachment 0016 12999545 (Dist A).pdf PDF
Attachment 0004 RAMS CONTRACT ADDENDUM - Quality Assurance Requirements.pdf PDF
Attachment 0019 HCSDS 02760 RSI-007.pdf PDF
Attachment 0009 DD2345 Military Critical Technical Data Agreement.pdf PDF
Attachment 0017 HCSDS 2795 (RAMS M17A1).pdf PDF
Attachment 0021 SFAE-AMO Form 3002.pdf PDF
Attachment 0022 GOVERNMENT FURNISHED PROPERTY LIST.xlsx XLSX spreadsheet
Attachment 0005 Past Performance Questionnaire.docx DOCX document
Attachment 0001_How to Read DD 1423_CDRLs.pdf PDF
Attachment 0008 AMSTA-AR 1350.pdf PDF
Attachment 0018 HCSDS 00993 PBX9407.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

Remote Activation Munition System (RAMS) M17A1 Receiver & M85A1 Trainer Receiver

Figure 1: FAT Testing Matrix

Environmental Condition Specification Configuration Reference Cold Storage Temperature

-50° F (+0/-5° F) Packaged in its PA108 container

MIL-STD-810H, Procedure I, Operational, Method 502.7

Hot Storage Temperature +160° F (+5/-0° F) Packaged in its PA108 container

MIL-STD-810H, Procedure I, Operational, Method 501.7

Transportation Vibration (Secured Cargo)

-50° F (+0/-5° F) and +160° F (+5/-0° F)

Packaged in its PA108 container

MIL-STD 810H, Method 514.8, ANNEX C, Category 4 - Truck/Trailer - Secured Cargo, (Two Wheeled Trailer, Table 514.8C-III and Composite Wheeled Vehicle, Table 514.8C-V)

Transit Drop (7 Foot) -50° F (+0/-5° F) and +160° F (+5/-0° F)

Packaged in its PA108 container

7 Foot Drop, IAW ITOP 4-2-602

Cold Operating Temperature

-25° F (+0/-5° F) Bare MIL-STD-810H, Procedure II, Operational, Method 502.7

Hot Operating Temperature

+135° F (+5/-0° F) Bare MIL-STD-810H, Procedure II, Operational, Method 501.7

Loose Cargo -25° F (+0/-5° F) and +135° F (+5/-0° F)

Bare in Rucksack/Pack ITOP 4-2-602, Ground Platform Shock/Vibration Levels, Rough Handling Tests, Appendix B

Transit Drop (4 Foot) -25° F (+0/-5° F) and +135° F (+5/-0° F)

Bare ITOP 4-2-602, Four (4) Foot drop on Two (2) inches of plywood

Immersion Ambient (73° F ±10° F)

Bare (*M17A1 only) Immersed in Sixty Six (66) Feet of Salt Water for 30 minutes

Performance Requirement Criteria Configuration Applicability Program Receiver Accepts program from Tx Receiver FAT/LAT Operational Test Receives test command from Tx Receiver FAT/LAT

Arming Error Notify of improper arming sequence

Receiver FAT/LAT

Proper Arming At least Five Minute Safe Separation Time

Receiver FAT/LAT

No-Go Function Test No Output before SST, on wrong code after SST

Receiver w/ Lead FAT/LAT

Fire/Output Lead Initiation Receiver w/ Lead FAT/LAT

Performance Requirement Criteria Configuration Applicability Program Receiver Accepts program from Tx Receiver FAT/LAT Operational Test Receives test command from Tx Receiver FAT/LAT

Arming Error Notify of improper arming sequence

Receiver FAT/LAT

Proper Arming At least Five Minute Safe Separation Time

Receiver FAT/LAT

No-Go Function Test No Output before SST, on wrong code after SST

Receiver w/ Lead FAT/LAT

Fire/Output Lead Initiation Receiver w/ Lead FAT/LAT