This solicitation is for an Increase IRM Physical Security Project at a Department of Veterans Affairs medical center. The solicitation seeks construction services including demolition, new walls, doors, flooring, ceilings and electrical and mechanical work. The project scope involves renovations to rooms on the third floor including the main computer room, medical records office, and telehealth areas. Construction will occur in two phases to minimize disruptions. The total project duration is estimated at 331 days from notice to proceed. Submissions are due by a specified date. The awarded firm will be expected to comply with all relevant construction standards and codes.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT DURATION

Third Floor Main IRM Rooms 3A133, 3A135 and 3A135B

Duration in Days from Notice Calendar Days of Award

Preconstruction Activities 90 Days 1 - 90 On-Site Construction (NTP)

Phase 1 120 Days 91 - 211 Phase 2 120 Days 212 - 331

Total Project duration is 331 days from Notice of Award.

Telecom Rooms - Sub-Basement, Basement, Floors 1 thru 6 and CARES Tower

Duration in Days from Notice Calendar days of Award

Preconstruction Activities 90 Days 1 - 90 On-Site Construction (NTP) 240 Days 91 - 331

Total Project duration is 331 days from Notice of Award.

PHASING GENERAL NOTES

1. The work shall be accomplished in two phases.

2. Contractor to coordinate all work with the entire set of documents.

3. Contractor to cooperate with the Owner's occupancy of the IRM

Rooms / facility and shall execute the work as to intefere as little as possible with the normal functioning of the IRM Rooms / Medical Center. See also Specification 01 00 00

4. Maintain positive pressure in Main Computer Room during construction.

5. Contractor to protect equipment during construction.

6. Main Computer Room (MCR)- Temporary enclosure by Value

Facility Services.

7. IDF Equipment rack - drape visqueen over rack during construction.

8. All shutdowns in this area are covered under major shutdowns.

DEDUCT ALTERNATE SUMMARY

Deduct Alternate No. 1 Delete all work associated with Telecom Closet doors in CARES Tower

Deduct Alternate No. 2 Delete all work associated with Telecom Rooms on the 6th, 5th, 4th & 3rd floors

Deduct Alternate No. 3 Delete all work associated with Telecom Rooms in Basement

Deduct Alternate No. 4 Delete all work associated with Telecom Rooms on 2nd & 1st floors

EAST BLVD.

E.

S

T.

EA

ST

B

LV

D

MAGNOLIA DR.

HA

ZE

L

DR

E. 108 ST.

MT. SINAI DR.

MARTIN LUTHER KING DR.

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

Drawing Title

Approved: Division Chief

Location

Project Title Date

Checked Drawn DRAWING NO.Building Number

Project No.

Office of Facilities

Management

Dwg. of on e ei gh th in ch o ne fo ot on e qu ar te r i nc h on e fo ot th re e ei gh th s in ch o ne fo ot on e ha lf in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

VA FORM 08-6231, OCT 1978 1

2 3 4 5 6 7 8 9

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A B

C D

E F

6"

6"

6"

6"

FACILITY MANAGER

DATE

SHOP FOREMAN 138

APPROVALS

CHIEF Planning and Construction

DATE

CHIEF, Occupational Health & Safety

APPROVALS

DIRECTOR 00

DATE

ASSOCIATE DIRECTOR 00A (B)

APPROVALS

Approved: Service Director

CHIEF, IRMCHIEF, ENGINEERING 138

DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER - WADE PARK

10701 EAST BLVD. CLEVELAND, OH. 44106

PROJECT NO.

DRAWING INDEX

U.S. GOVERNMENT PRINTING OFFICE: 1983-400-285

ARCH JOB NO.:

FULLY SPRINKLERED

SITE PLAN

Scale = None

True North

Fredrick, Fredrick & Heller Engineers, Inc.

Mechanical & Electrical Engineers 672 East Royalton Road Broadview Heights, Ohio 44147

Plan North

Perspectus Architecture LLC Architect 13212 Shaker Square Cleveland, Ohio 44120

Increase IRM Physical Security

541-19-102

DRTH

Cover Sheet

X.1

541-19-102

BID ISSUE

APRIL 13, 2020

APRIL 13, 2020

Increase IRM Physical Security

18-145

10701 EAST BLVD. CLEVELAND, OHIO

ELECTRICAL

E0.1 Electrical Legend and General Notes E0.2 Lighting Fixture Schedule and Appearance Guide E1.1 Sub Basement Electrical Key Plan E1.2 Basement Electrical Key Plan E1.3 First Floor Electrical Key Plan E1.4 Second Floor Electrical Key Plan E1.5 Third Floor Electrical Key Plan E1.6 Fourth Floor Electrical Key Plan E1.7 Fifth Floor Electrical Key Plan E1.8 Sixth Floor Electrical Key Plan E2.1 Partial Third Floor Lighting and Fire Alarm Demolition

Plan - Phase 1 E2.2 Partial Third Floor Power and Security Demolition

Plan - Phase 1 E2.3 Partial Third Floor Lighting and Fire Alarm Demolition

Plan - Phase 2 E2.4 Partial Third Floor Power and Security Demolition

Plan - Phase 2 E3.1 Partial Third Floor Lighting and Fire Alarm Plan -

Phase 1 E3.2 Partial Third Floor Power and Security Plan - Phase 1 E3.3 Partial Third Floor Lighting and Fire Alarm Plan -

Phase 2 E3.4 Partial Third Floor Power and Security Plan - Phase 2 E3.5 Partial Third Floor Main Computer Room Final Layout

Plan E4.1 Enlarged Telecom Room Plans E4.2 Enlarged Telecom Room Plans E4.3 Enlarged Telecom Room Plans E4.4 Enlarged Telecom Room Plans E4.5 Enlarged Telecom Room Plans E4.6 Enlarged Telecom Room Plans E5.1 Power Distribution One-Line Diagram Legend E5.2 Power Distribution One-Line Diagram E5.3 Panelboard Schedules E5.4 Emergency Power Off (EPO) System Diagram and

Notes E7.1 Access Control Details E7.2 Electrical Details E7.3 Electrical Details

TECHNOLOGY

T0.1 Technology Legend and General Notes T2.1 Partial Third Floor Technology Demolition Plan -

Phase 1 T2.2 Partial Third Floor Technology Demolition Plan -

Phase 2 T3.1 Partial Third Floor Technology Plan - Phase 1 T3.2 Partial Third Floor Technology Plan - Phase 2 T4.1 Technology Grounding Details T4.2 Technology Rack Details

GENERAL

X.1 Cover Sheet

ARCHITECTURAL

A0.1 Reference Information & Door Schedule A0.2 Partial Third Floor Life Safety Plan A1.0 Overall Sub-Basement Floor Plan A1.1 Overall Basement Floor Plan A1.2 Overall First Floor Plan A1.3 Overall Second Floor Plan A1.4 Overall Third Floor Plan A1.5 Overall Fourth Floor Plan A1.6 Overall Fifth Floor Plan A1.7 Overall Sixth Floor Plan A2.1 Third Floor Phase 1 Plans A2.2 Third Floor Phase 2 Plans A3.1 MISC Details & Finish Schedule

MECHANICAL

M0.1 Mechanical Legend and General Notes M1.1 Partial Third Floor Ductwork Demolition Plan - Phase 1 M1.2 Partial Third Floor HVAC Piping Demolition Plan - Phase 1 M1.3 Partial Third Floor Ductwork Demolition Plan - Phase 2 M1.4 Partial Third Floor HVAC Piping Demolition Plan - Phase 2 M2.1 Partial Third Floor Ductwork Plan - Phase 1 M2.2 Partial Third Floor HVAC Piping Plan - Phase 1 M2.3 Partial Third Floor Ductwork Plan - Phase 2 M2.4 Partial Third Floor HVAC Piping Plan - Phase 2 M2.5 Partial First Floor, Basement and Sub-Basement HVAC

Piping Plans M2.6 Partial First and Second Floor HVAC Piping Plans M3.1 Mechanical Details M3.2 Mechanical Schedules

PLUMBING

P0.1 Plumbing Legend and General Notes P1.1 Partial Third Floor Plumbing and Fire Protection Demolition

Plan - Phase 1 P1.3 Partial Third Floor Plumbing and Fire Protection Demolition

Plan - Phase 2 P2.1 Partial Third Floor Plumbing and Fire Protection Plan -

Phase 1 P2.3 Partial Third Floor Plumbing and Fire Protection Plan -

Phase 2

SYMBOLS

Building, wall and detail section mark

Interior/exterior elevation reference

Enlarged plan or detail reference

Column reference grids

Revision reference number

Wall type

Window type

New level line, control point, or datum

New door

Indicates drawing sheet on which plan/detail is shown.

Indicates detail number

Indicates drawing sheet on which elevation is shown

Indicates elevation number

Indicates drawing sheet on which section is shown

Indicates section number

Door number46

XX

A

A2-1

A2-1

A2-1

A

Crown typeXX

Wall finish

A

New Existing

XX

anchor bolt above air conditioning acoustic(al) acoustical ceiling tile adjacent above finish floor alternate aluminum anodized approximate architect(ural) automatic

AB

ABV

A/C

ACOUS

ACT

ADJ

AFF

ALT

ALUM

ANOD

APPROX

ARCH

AUTO

board between building block(ing) bulkhead beam bottom bridging bearing brick basement built-up roofing

BD

BETW

BLDG

BLK

BLKHD

BM

BOT

BRDG

BRG

BRK

BSMT

BUR

CFM

CG

CI

CJ

CLG

CL

CLR

CLL

CNTR

CMU

CO

COL

CONC

CONN

CONST

CONT

COORD

CORR

CS

CTR

CL

cubic feet per minute corner guard cast iron control joint ceiling closet clear contract limit line counter concrete masonry unit cased opening/clean out column concrete connection construction continuous coordinate corridor course center

D

DBL

DEG

DEMO

DIA

DIM

DISP

DN

DR

DS

DET

DWG

DWR

DW

depth double degrees demolition diameter dimension dispenser down door down spout detail drawing drawer drywall each electrical contractor exterior insulation and finish system expansion joint electric elevator/elevation emergency equal equipment exposed structure existing to remain each way electric water cooler exhaust existing expansion exposed exterior

EA

EC

EIFS

EJ

ELEC

ELEV

EMERG

EQ

EQUIP

ES

ETR

EW

EWC

EXH

EXIST

EXP

EXP'D

EXT

fire alarm face brick fan coil unit face to face floor drain foundation fire extinguisher fire extinguisher cabinet fire hose cabinet finish floor fluorescent fire resistant

FA

FB

FCU

F/F

FD

FDN

FE

FEC

FHC

FIN

FLR

FLUOR

FR

GA

GALV

GC

GL

GR

GYP BD

gauge galvanized general contractor glass grade gypsum board

H

HB

HC

HDBD

HDCPD

HDWR

HDWD

HM

HORIZ

HPDL

HR

HT

HTG

HTR

HVAC

HW

HWH

high hose bibb hollow core hardboard handicapped hardware hardwood hollow metal horizontal high pressure decorative laminate hour height heating heater heating, ventilation air conditioning hot water hot water heater

ID

IN

INCL

INSUL

INT

inside diameter inch include (inclusive) insulation interior janitor joist

JAN

JST

knock down knock out

KD

KO

L

LAM

LAV

LB

LF

LIM

LT

LTG

LVR

length (long) laminate(d) lavatory pound linear feet (foot) limited light lighting louver

MARB

MAS

MAT

MAX

MECH

MEMB

MFR

MH

MIN

marble masonry material maximum mechanical membrane manufacturer manhole minimum not applicable not in contract number nominal not to scale

N/A

NIC

NO

NOM

NTS

overall on center on center above finish floor outside diameter overhead door opposite hand overflow roof drain out to out opening opposite optional

OA

OC

OCAFF

OD

OHDR

OPH

OVRD

O/O

OP'G

OPP

OPT

PLBG

PMLD

PNL

PLYWD

POL

PP

PR

PREFIN

PREFAB

PROJ

PSC

PSF

PSI

PT

PTD

PTN

PVC

PVMT

plumbing premoulded panel plywood polished push plate pair prefinished prefabricated projection pre-stress concrete pounds per square foot pounds per square inch point painted partition polyvinylchloride pavementQTY quantity

R

RA

RAD

RAG

RD

REC

REF

REG

REINF

riser return air radius return air grille roof drain receptacle refrigerator register reinforcement solid core schedule smoke detector saddle section sheet similar stand pipe specifications speaker sprinkler single ply roofing square square inch square yard stainless steel/ slop sink standard steel storage structure(al) suspended systems

SC

SCHED

SD

SDL

SECT

SHT

SIM

SP

SPEC

SPKR

SPKLR

SPR

SQ

SQ IN

SY

SS

STD

STL

STOR

STRUC

SUCP

SYS

T T/G or T&G

TG

TD

TEL

TEMP

TEMP'D

TERR

THK

THLD

TOC

TOS

TOD

TOM

TOJ

TOP

TOW

TYP

thread tongue and groove tempered glass trench drain telephose temporary tempered terrazzo thick threshold top of concrete (top of curb) top of steel top of deck top of masonry top of joist top of parapet top of wall typicalundercut underground unfinished unlimited unless noted otherwise urinal

UC

UG

UNFIN

UNLIM

UNO

UR

VERT

VEST

VIF

vertical vestibule verify in field

W W/ W/O W/W

WC

WD

WH

WIN

WG

WT

WWF

width with without wall to wall water closet wood water heater window wire glass weight welded wire fabric

YD yard

ABBREVIATIONS

C/C

CAB'T

CAD

CB

CEM

CL or center to center cabinet cadmium catch basin cement center line fire-retardant treated fire-retardant treated wood feet footing furring fire valve cabinet

FRT

FRTWD

FT

FTG

FURR

FVC

MISC

MO

MTD

MTG

MTL

MULL

miscellaneous masonry opening mounted mounting metal mullion

PBD

PCF

PERIM

PG BD

PL

PLAS

PLAM

particle board pounds per cubic foot perimeter peg board plate plastic plastic laminate

REINF

REQ'D

RES

RET

REV

RM

RO

RVS

reinforcement (reinforcing) required resilient return revised (revision) room rough opening reverse

A

See specifications for sealant type.

All joints 1" wide or more are to be laid up in beads and tooled to profile indicated.

All joints are to be primed before bond breaking rod is installed.

Install bond breaking rod with roller to proper depth. No sharp tools permitted.

1.

2.

3.

4.

Notes:

B C

Wall material varies

07 92 00 - Bond breaker rod

07 92 00 - Sealant

Joint Schedule Dimensions

A B C 3/8" 1/8" 1/4"

1/2" 1/8" 3/8"

5/8" 1/8"

3/4" 1/8"

7/8" 1/8"

1" 1/8"

3/8"

3/8"

3/8"

3/8"

UNO

6"

Partition assembly

Door frame

TYP of all frames that occur at room corner locations, UNO

5/8" Type X GYP BD MTL studs

Control joint, both sides

MAX

1/2"

5/8" Type X GYP BD

TYP of all control joints located in rated wall assemblies

MAX

1/2"

MAX

1/2"

1 13/16"

I. General Notes

1. Do not scale drawings. Contractor(s) are to verify site dimensions and conditions prior to work.

2. Construction shall be in accordance with the requirements of the applicable codes including accessibility standards and the requirements of “Americans with Disabilities Act.”

3. Contractor(s) shall visit the site and correlate the requirements of the documents with the existing conditions.

4. Drawings are diagrammatic and since existing conditions, including areas above accessible ceilings may affect new work, the contractor shall coordinate and alter new work to properly fit the existing conditions. The work shall be performed at no extra cost. The contractor shall verify all conditions and dimensions at the job site prior to the start of construction. If discrepancies are found, the architect shall be notified for clarification before commencing with the work.

5. Details not shown are similar in character to those shown. When specific dimensions, details, or design intent cannot be determined, consult the architect before proceeding with the work.

6. Some masonry and lumber dimensions shown on the drawings are nominal dimensions. Contractor(s) shall coordinate actual dimensions with the job conditions.

Report all discrepancies to the architect.

7. Existing conditions shown on this drawing are not guaranteed to be complete. The contractor(s) shall field verify all existing conditions, dimensions, and materials required for the contracted work. Report all discrepancies to the architect prior to fabrication and erection.

8. The term ‘patch to match’ or ‘cutting and patching’ denotes that repair work is necessary to construct a floor, base, wainscot, wall or ceiling to match its adjacent surface, texture, material, finish and color of adjacent existing surfaces.

9. If materials suspected of containing hazardous materials are encountered, DO NOT DISTURB; immediately notify the owner.

10. Where existing partitions or services have been removed, or new services penetrate existing surfaces, the openings shall be patched to match the existing surface finish, texture, and sheen. Provide firestopping at rated walls, see Life Safety Plans for locations.

11. Where new openings occur in structural bearing wall, contractor is responsible for temporary supports and/or shoring as required for installation of lintels.

12. Where existing doorways are to be filled in, contractor is responsible for field verifying wall widths.

13. The General Contractor is responsible for installation of all access doors, access panels and frames, including, but not limited to those specific in the construction documents and furnished by other contractors. General contractor should attempt to locate devices requiring access above ACT, in order to limit the quantity of access doors; coordinate locations of devices with the Reflected Ceiling Plans. All access doors and panel locations to be coordinated and approved by the architect prior to installation. The general contractor is responsible for painting all access panels and access doors. General contractor is responsible for coordinating all paint colors with the architect prior to commencing with the work.

II. Fire Resistance Rating

1. Fire rating indicated on a wall shall mean the entire length and height of wall to be fire rated.

2. All piping, ducts, cabinets, etc. that penetrate walls shall be installed in a manner that wil preserve the fire resistance rating of that wall.

3. Preserve all fire resistant ratings of existing wall unless otherwise noted.

III. Dimensioning

1. Interior partitions are dimensioned to face of gypsum board exclusive of finish material, such as ceramic tile or wood paneling. The contractor shall coordinate finish dimensions with finish schedule when critical to the installation of millwork or equipment.

fo r w al l t yp e

Se e pl an s

09 29 00 - GYP BD.

See plan for wall type

09 22 16 - DBL studs back to back

07 21 13 - Acoustical INSUL

08 11 13 - Hollow Metal rame

2"5/8"

07 21 13 - Acoustical INSUL

07 92 00 - Sealant (typical all sides)

1/ 2"

1/ 2"

/1 6"

/1 6" for wall type See plans

09 22 16 - MTL studs

09 29 00 - Acoustical

INSUL

08 11 13 - HM frame2" 5/

8"

07 21 13 - Acoustical INSUL

07 92 00 - Sealant (typical all sides)

09 29 00 - GYP BD.

See plan for wall type

1/2" 1/2"

1 15/16" 1 15/16"

EXIST CMU wall; Patch to match where impacted by demolition.

08 11 13 - Frame anchor may occur, replace where REQD

08 11 13 - Hollow Metal frame, grout solid

5/8" 2"

Se e pl an

5/

8" o r 1

5/ 8"

1"

/1

6"

7/ 8"

07 92 00 - Sealant (typical all sides)

/1 6"

08 11 13 - Hollow Metal frame

VI

F

2" o r 4

5/ 8" 1"

1 15/16" 1 15/16"

5 7/8"

07 92 00 - Sealant (TYP)

See Plan 7 5/8" or 11 5/8"

EXIST CMU wall; Patch to match where impacted by demolition.

Type B

Metal Stud Partition;

Extend GYP BD from top of concrete floor to underside of opening.

AB

Extend GYP BD to underside of STRUC above

09 22 16 - Deflection track

09 29 00 - (1) layer of 5/8" fire resistant GYP BD EA side 07 21 13 - 3 1/2" sound attenuation blanket 09 22 16 - 6" MTL studs @

16" OC

07 92 00 - Sealant

09 22 16 - Deflection track

09 29 00 - (1) layer of 5/8" fire resistant GYP BD this side

09 22 16 - 3 5/8" MTL studs

@ 16" OC

07 92 00 - Sealant

7 1/4"4 1/4"

Type A

Metal Stud Partition

A1 Type A1

Sames as Type 'A' above, except provide 3 5/8" metal studs in lieu of 6" metal studs.

Same as Type 'A' above except (1) layer of Type 'X' 5/8" gypsum board each side and fire caulk both sides of deflection track. (1) hour fire rated assembly, per UL Design U423.

A2 Type A2Type B1

Metal Stud Partition;

Same as Type B, except add 09 29 00 - 3 1/2" sound attenuation blanket.

B1

Extend GYP BD to underside of opening

C

Extend GYP BD to underside of STRUC above

09 29 00 - (1) layer of 5/8" fire resistant GYP BD

Type C

Mesh Security Patch

09 22 36 - Security barrier mesh

Existing wall to remain

(VIF)

Existing INSUL to remain

(VIF)

D

Extend GYP BD to underside of opening

09 22 16 - Deflection track

09 29 00 - (2) layer of 5/8" fire resistant GYP BD EA side

09 22 16 - 3 5/8" MTL studs

@ 16" OC

07 92 00 - Sealant

6 1/8"

Type D

Metal Stud Partition 2 Hour rating

UL #425

Hollow MTL

Type F1

Swing Door Hollow MTL

Type

Swing Door Hollow MTL

Type D2D1

Back to back boxes NOT permitted Stagger Boxes

07 92 00 - silicone acoustical sealant, TYP both sides

Gypsum board - see wall types for quantity of layers

07 92 00 - silicone acoustical sealant, TYP both sides

M

AX3/

8"

M

AX1/

2"

EXIST Precast CONC wall

08 11 13 - Hollow Metal frame

07 92 00 - Sealant (TYP)

09 22 16 - MTL studs

2" 5/

8"

EXIST GYP BD

1 15/16" 1 15/16"

5 7/8"

1/2"

See plan 1'-4 1/4" +/- 08 11 13 - Hollow Metal frame

5/8" 2"

/1 6"

/1 6"

7/

8"

07 92 00 - Sealant (typical all sides)

09 22 16 - MTL studs

EXIST GYP BD

Se e pl an

1' -4

/4

EXIST Precast CONC wall

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Reference Information & Door Schedule

A0.1 4/13/20

TYP Sealant Detail

TYP Frame Location

Fire Resistant Control Joint

Jamb Detail J1Head Detail H1

Jamb Detail J2Head Detail H2

WALL PARTITION TYPESDOOR FRAME TYPESDOOR TYPES

TYP Electrical / Junction Box

TYP Acoustical Partition

DOOR SCHEDULE

NUMBER

DOOR FRAME

NOTES

OPENING SIZE

PAIR TYPE LABEL TYPE MATERIAL JAMB HEADWIDTH HEIGHT

1A114 0" 0" ETR ETR 1

1A181 0" 0" ETR ETR 1

1AC262 0" 0" ETR ETR 1

1B100 0" 0" ETR ETR 1

1B468 0" 0" ETR ETR 1

1B496 0" 0" ETR ETR 1

1C300D 0" 0" ETR ETR 1

1C519 3' - 0" 7' - 0" D1 ETR 1

1D211 7' - 0" 0" ETR ETR 1

1E257 0" 0" ETR ETR 1

1E334 0" 0" ETR ETR 1

1E491 0" 0" ETR ETR 1

1F515 0" 0" ETR ETR 1

1FLVC1 0" 0" ETR ETR 1

2A103 0" 0" ETR ETR 1

2A158 0" 0" ETR ETR 1

2A186 0" 0" ETR ETR 1

2B149 0" 0" ETR ETR 1

2C134A 3' - 0" 7' - 0" D1 20 MIN F1 HM J1 H1 1

2C134B 3' - 0" 7' - 0" D1 90 MIN F1 HM J2 H2 1

2C363 0" 0" ETR ETR 1

2E331 0" 0" ETR ETR 1

2FLVC1 0" 0" ETR ETR 1

3A101A 0" 0" ETR ETR 1

3A101B 3' - 0" 7' - 0" D1 90 MIN F1 HM J2 H2 1

3A133A 5' - 0" 7' - 0" Yes D2 20 MIN F1 HM J1 H1

3A133B 0" 0" ETR ETR

3A135 0" 0" ETR ETR

3A135BA 3' - 0" 7' - 0" D1 F1 HM J1 H1

3A135BB 3' - 0" 7' - 0" D1 F1 HM J3 H3

3A135C 0" 0" ETR ETR

3AC267 0" 0" ETR ETR 1

3AC322 0" 0" ETR ETR 1

3B129 0" 0" ETR ETR 1

3B162C 0" 0" ETR ETR 1

3FLVC1 0" 0" ETR ETR 1

4A101A 0" 0" ETR ETR 1

4A101B 3' - 0" 7' - 0" D1 90 MIN F1 HM J2 H2 1

4AC231 0" 0" ETR ETR 1

4AC352 0" 0" ETR ETR 1

4B145 0" 0" ETR ETR 1

4FLVC1 0" 0" ETR ETR 1

5A100A 0" 0" ETR ETR 1

5A100B 3' - 0" 7' - 0" D1 90 MIN F1 HM J2 H2 1

5B156 0" 0" ETR ETR 1

5FLVC1 0" 0" ETR ETR 1

6A100A 0" 0" ETR ETR 1

6A100B 3' - 0" 7' - 0" D1 90 MIN F1 J2 H2 1

6B119 0" 0" ETR ETR 1

6FLVC1 0" 0" ETR ETR 1

AFLVC1 0" 0" ETR ETR 1

BA149 0" 0" ETR ETR 1

BA151A 0" 0" ETR ETR 1

BAC308 0" 0" ETR ETR 1

BB379 0" 0" ETR ETR 1

BB471 0" 0" ETR ETR 1

BC505 3' - 0" 7' - 0" D1 ETR 1

BD421 0" 0" ETR ETR 1

BF101 6' - 0" 7' - 0" Yes D2 F1 HM J1 H1 1

BF312 0" 0" ETR ETR 1

BF515 3' - 0" 7' - 0" D1 F1 HM J3 H3 1

BFLVC1 0" 0" ETR ETR 1

K122A 5' - 0" 0" Yes ETR ETR 1 K223 5' - 0" 7' - 0" Yes D2 FI HM J1 H1 1

Head Detail H3 Jamb Detail J3

DOOR SCHEDULE NOTES

- Coordinate new door and frame finish with specification 08 11 13 - Hollow Metal Doors and Frames

- See specification 08 71 11 - Door Hardware for door hardware set types

- Contractor to verify existing door and frame sizes where new doors and frames are scheduled to be provided.

1. See Overall Plans for Deduct Alternates.

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

ETRETR

Code Information Healthcare Occupancies Design Code 2018 NFPA 101 Life Safety Code Occupancy Separations 2 hours between Healthcare and Ambulatory Care (Table 6.1.14.4.1 & 6.1.14.4.3) 2 hours between Healthcare and Business

2 hours between Healthcare and Industrial Fire Suppression (18.3.5.1) Fully Sprinklered Construction Type (Table 18.1.6.1) Type II (222)

Greater than 4 stories permitted Fire Ratings (Table A.8.2.1.2)

Exterior Bearing Walls 2 hours 1 hour supporting roof only

Interior Bearing Walls 2 hours 1 hour supporting roof only

Columns/Beams/Girders 2 hours 1 hour supporting roof only

Floor-Ceiling Assemblies 2 hours Roof-Ceiling Assemblies 1 hour Interior Non-Bearing Walls 0 hours Exterior Non-Bearing Walls 0 hours

Exit Enclosures/Passageways (7.1.3.2.1.3) 1 hour for less than 4 stories 2 hours for 4 stories or more 1 hour for existing if building is fully sprinklered

Shaft Enclosures (8.6.5) 2 hours for 4 stories or more 1 hour for less than 4 stories

Communicating Spaces (18.3.1.5) Not permitted Atriums (18.1.3.2, 18.3.1, 8.6.7) 1 hour with exceptions Convenience Openings (18.3.1, 8.6.9) Permitted Exit Access Corridors (18.3.6.2) 0 hour smoke partitions Corridor Width (18.2.3.4) 96" minimum

44" minimum in non-inpatient areas Dead End Corridors (Table 18.2.5.2) 30' maximum Smoke Compartments (18.3.7.1.3.a) 22,500 sf maximum Smoke Barriers (18.3.7.3) 1 hour Suite

Non-sleeping (18.2.5.7.3.2 A&B) 12,500 sf maximum, 15,000 sf with smoke detection Sleeping (18.2.5.7.2.3 C) 7,500 sf maximum, 10,000 sf with direct supervision and smoke detection Sleeping means of egress (18.2.5.7.2.2 B) 2 over 1000 sf Non-sleeping means of egress (18.2.5.7.3.1 B) 2 over 2500 sf Walls (18.2.5.7.1.2 & 18.3.6.2) 0 hour smoke partitions

Hazardous Area Protection (18.3.2.1) Boiler and fuel-fired heater rooms 1 hour Central/bulk laundries larger than 100 sf 1 hour Paint shops less than severe hazard 1 hour Physical plant maintenance shops 1 hour Soiled linen rooms exceeding 64 gal 1 hour Trash rooms exceeding 64 gal 1 hour Storage rooms larger than 50 sf (18.3.2.1.3.2) Storage rooms larger than 100 sf 0 hour smoke partitions Labs with non-severe hazard materials (18.3.2.1.3.2) 0 hour smoke partitions Labs with severe hazard materials (18.3.2.2) NFPA 45

Travel Distances Room remote point to exit (18.2.6.2.1) 200' maximum Sleeping room remote point to exit access 50' maximum door (18.2.6.2.3) Sleeping suite remote point to exit access 100' maximum door (18.2.5.7.2.4 A) Sleeping suite remote point to exit (18.2.5.7.2.4 B) 200' maximum Non-sleeping suite remote point to exit 100' maximum access door (18.2.5.7.3.3 A) Non-sleeping suite remote point to exit 200' maximum (18.2.5.7.3.3 B) Room remote point to smoke barrier (18.3.7.1.5) 200' maximum Common path of travel (19.2.5.3) Not limited Common path of travel (18.2.5.3) 100' maximum

1 hour

UP

UP

UP

UP

UP

3A126

EMS

3A128

EMS

3A134

L.C.

3A130

L.C.

3A132

3A124 3A108B

3A108A

MCR

3A133

FMS

3A135

MCOR

3A135B

Tele Health 3A1373A1393A1413A1433A145

2 Bedroom 3A1313A129

3A127

3A125

3A123

3A110

3A114

3A116

3A121

3A119

3A117

3A1153A113

3A118 3A120 3A122

3A108

3A147

P R O J E C T S C O P E

P R O J E C T S C O P E

CONSTRUCTION STAGING AREA

Replace existing door with temporary door and construction hardware.

A

HE

EX

EX

144'-0" TRAVEL DISTANCE

192'-0" TRAVEL DISTANCE

LIFE SAFETY LEGEND

2 HR Fire Barrier

2 HR Smoke Barrier

1 HR Fire Barrier

1 HR Smoke Barrier

0 HR Smoke Partition

Fire Extinguisher

Exit Sign

Exit

Horizontal Exit

Hazardous Room

Suite

LIFE SAFETY GENERAL NOTES

1. See Cover Sheet for applicable code information.

2. Contractor shall preserve all fire resistant ratings of existing walls, UNO

3. See plans for location of rated walls. When rated walls are encountered during the course of construction, contractor shall maintain indicated ratings by firestopping or patching with materials or shall perform other work necessary which will maintain indicated ratings.

4. The fire rating indicated on a wall shall mean the entire length and height of wall.

5. All rated walls within Project Scope Area shall be stenciled with wall rating. Refer to Specification 09 91 00.

6. Existing smoke compartments will not be impacted by this project.

EX

HE

SUITES

LETTER NAME AREA TYPE EXIT ACCESS

DOORS

A IRM 2,870SF Non-Patient Care 3

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Partial Third Floor Life Safety Plan

A0.2 4/13/20

Scale

4' 8' 16' 1/8" = 1'-0"

PARTIAL THIRD FLOOR LIFE SAFETY PLAN1 THIS DRAWING SHALL BE PRINTED IN FULL COLOR FOR CLARITY

BLACK AND WHITE FACSIMILES ARE NOT CONSIDERED PART OF

THE CONSTRUCTION DOCUMENT SET.

UP

AFLVC1

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Sub-Basement Floor Plan

A1.0 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL SUB-BASEMENT FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Room AFLVC1; Existing doors and hardware to remain;

Delete new access controls.

16' 32' 64'

DN

DN

DN

DN

BF312

BD421

BB471

BB379

BC505

BA149

BA151A

BAC308

BF515

BF101

BFLVC1

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Basement Floor Plan

A1.1 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL BASEMENT FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Rooms BF101 and BFLVC1; Existing doors and hardware to remain; Delete new access controls.

DEDUCT ALTERNATE NO. 3

Revise the Scope of Work as follows:

1. Telecom Rooms BA149, BA151A, BA308, BB379, BB471, BD421 and BF312; Existing doors and hardware to remain; Delete new access controls.

2. Telecom Rooms BC505 and BC515; Existing doors, door frames and hardware to remain, in lieu of new; Delete new access controls.

DN

DN

DN

DN

DN

1B496

1B100

1E491

1AC262

1A181

1A114

1C519

1C300D

1E2571E334

K122A

1F515

1FLVC1

1D211

1B468

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall First Floor Plan

A1.2 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL FIRST FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Room 1FLVC1; Existing doors and hardware to remain;

Delete new access controls.

DEDUCT ALTERNATE NO. 4

Revise the Scope of Work as follows:

1. Telecom Rooms 1A114, 1A181, 1AC262, 1B100, 1B468, 1B496, 1C300D,1C519, 1D211, 1E257, 1E334, 1E491, 1F515 and K122A;

Existing doors and hardware to remain; Delete new access controls.

2FLVC1

K223

2E331

2C134A

2B149

2C363

2A186

2A158

2A103

2C134B

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Second Floor Plan

A1.3 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL SECOND FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Room 2FLVC1; Existing doors and hardware to remain; Delete new access controls.

DEDUCT ALTERNATE NO. 4

Revise the Scope of Work as follows:

1. Telecom Rooms 2A103, 2A158, 2A186, 2B149, 2C363, 2E331 and K223;

Existing doors and hardware to remain; Delete new access controls.

2. Telecom Rooms 2C134A and 2C134B; Existing doors, door frames and hardware to remain, in lieu of new; Delete new access controls.

16' 32' 64'16' 32' 64'

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UP

UPUP

See A2.1 and A2.2 for Scope of Work and Phasing information.

3FLVC1

3B129

3B162C

3A101A

3AC322

3AC267

3A101B

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Third Floor Plan

A1.4 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL THIRD FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Room 3FLVC1; Existing doors and hardware to remain;

Delete new access controls.

DEDUCT ALTERNATE NO. 2

Revise the Scope of Work as follows:

1. Telecom Rooms 3A101A, 3A101B, 3AC267, 3AC322, 3B129 and 3B162C; Existing doors and hardware to remain; Delete new access controls.

UP

UP

UP

UP

UP

UP

UP

UP

UPUP

4AC231

4AC352

4A101A

4B145

4FLVC1

4A101B

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Fourth Floor Plan

A1.5 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL FOURTH FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Room 4FLVC1; Existing doors and hardware to remain; Delete new access controls.

DEDUCT ALTERNATE NO. 2

Revise the Scope of Work as follows:

1. Telecom Rooms 4B145, 4A101A, 4AC352 and 4AC231; Existing doors and hardware to remain; Delete new access controls.

2. Telecom Room 4A101B; Existing door, door frame and hardware to remain, in lieu of new; Delete new access controls.

UP

UP

UP

5FLVC1

5B156

5A100A

5A100B

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Fifth Floor Plan

A1.6 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL FIFTH FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Rooms 5FLVC1; Existing doors and hardware to remain;

Delete new access controls.

DEDUCT ALTERNATE NO. 2

Revise the Scope of Work as follows:

1. Telecom Rooms 5A100A and 5B156; Existing doors and hardware to remain; Delete new access controls.

2. Telecom Room 5A100B; Existing door, door frame and hardware to

UP

UP

UP

UP

6FLVC1

6B119

6A100A

6A100B

PROJECT SCOPE

FLOOR PLAN LEGEND

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Overall Sixth Floor Plan

A1.7 4/13/20

Scale

4' 8' 16' 1/32" = 1'-0"

OVERALL SIXTH FLOOR PLAN1

DEDUCT ALTERNATE NO. 1

Revise the Scope of Work as follows:

1. Telecom Room 6FLVC1; Existing doors and hardware to remain; Delete new access controls.

DEDUCT ALTERNATE NO. 2

Revise the Scope of Work as follows:

1. Telecom Rooms 6A100A and 6B119; Existing doors and hardware to remain; Delete new access controls.

2. Telecom Room 6A100B; Existing door, door frame and hardware to

UP UP

36 37

H

J

K

L

P

39 42

P R O J E C T S C O P E

P R O J E C T S C O P E

MCR

3A133

3A135C

MCOR

3A135B

FMS

3A135

3A135A

Closet

3A135BA

2 Bedroom 3A131

EMS

3A128

L.C.

3A130

EMS

3A134 L.C.

3A132

Toilet/ Shower 3A137A

Tele Health 3A137

3A135BB

AA1

3A133A

A1A1

EQ 5'-0" EQ 5'-1"

A1

3A135BA

3A135

3A133B

3A135C

Passage

3AC312

Corridor 3A100E

Stand Up Workstation

(NIC)

EX UPS

Align

Align

36 37

H

J

K

L

P

39 42

P R O J E C T S C O P E

P R O J E C T S C O P E

Passage

3AC312

3' -0

5 7

5 7

EX UPS

36 37

H

J

K

L

P

39 42

P R O J E C T S C O P E

P R O J E C T S C O P E

8' - 6" 8' - 6"

Passage

3AC312

MCR

3A133

3A135C

3A135A 3A135A

MCOR

3A135B

FMS

3A135

DEMOLITION PLAN LEGEND

Existing construction to remain

Construction to be demolished

# Number represents coded demolition note

Existing construction to remain

New construction

FLOOR PLAN LEGEND

# Number represents coded floor plan note

Toilet/ Shower 3A137A

Tele Health 3A137

EMS

3A134 L.C.

3A132

EMS

3A128

L.C.

3A130

FMS

3A135

MCOR

3A135B

3A135A

MCR

3A133

3A135C

2 Bedroom 3A131

Closet

3A135BA

Corridor 3A100E

REFLECTED CEILING PLAN LEGEND

GWB-1; 5/8" Gypsum Board

ACT-1; 2'-0" x 2'-0" Acoustical Ceiling Tiles

2'-0" x 2'-0" Light fixture

4'-0" Suspended light fixture

Supply grille / diffuser

Return grille / register

Number represents coded reflected ceiling plan note

R E G

I STERED ARCH

I T E C T

WILLIAM

CURTISS

AYARS

ST

AT

E OF OHIO

William Curtiss Ayars, License #7259 Expiration Date 12/31/2021

DESIGN AND CONSTRUCTION DOCUMENTS AS

INSTRUMENTS OF SERVICE ARE GIVEN IN

CONFIDENCE AND REMAIN THE PROPERTY OF

PERSPECTUS ARCHITECTURE. THE USE OF THIS

DESIGN AND THESE CONSTRUCTION DOCUMENTS

FOR PURPOSES OTHER THAN THE SPECIFIC

PROJECT NAMED HEREIN IS STRICTLY

PROHIBITED WITHOUT THE EXPRESSED WRITTEN

CONSENT OF PERSPECTUS ARCHITECTURE.

COPYRIGHT C 2020.

13212 Shaker Square Suite 204 Cleveland, Ohio 44120 P. 216.752.1800 F. 216.752.3833

CONSULTANTS: ARCHITECT:

Drawing Title

Approved: Project Director Location

Project Title

Date Checked Drawn

Drawing Number

Building Number

Project Number

Office of Facilities

Management

Dwg. of o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 7 8 9 10

A

1 2 3 4 5 6 7 8 9 10

B

C

D

E

F

A

B

C

D

E

F

VAMC - WADE PARK

Revisions: Date

FULLY SPRINKLERED

BID ISSUE 4/13/20

FREDRICK, FREDRICK & HELLER

ENGINEERS, INC.

672 EAST ROYALTON ROAD

BROADVIEW HTS., OHIO 44147

TEL. (440)546-9696

FAX: (440)546-9699

Increase IRM Physical Security

541-19-102

DRTH

Third Floor Phase 1 Plans

A2.1 4/13/20

Scale

4' 8' 16' 1/8" = 1'-0"

THIRD FLOOR PLAN - PHASE 12

Scale

4' 8' 16' 1/8" = 1'-0"

THIRD FLOOR DEMOLITION PLAN - PHASE 11

Scale

4' 8' 16' 1/8" = 1'-0"

THIRD FLOOR REFLECTED CEILING PLAN - PHASE 13

DEMOLITION CODED NOTES

1 Remove interior partition from floor to underside of structure above. Prepare all adjacent surfaces to receive new construction and scheduled finish. Existing walls shown to be removed shall be demolished complete. This includes the removal of reinforcement, soffits, doors, windows, frames and overhead bracing. COORD with MECH and ELEC for disconnection and removal of EXIST utilities and devices located within areas scheduled to be demolished.

2 Remove portion of existing wall from floor to 7'-0"H. Patch edges of opening and adjacent surfaces to match.

3 Remove existing door, frame, anchors, thresholds, and hardware as indicated. Patch and repair wall and floor to match existing. Owner shall have the right to salvage any and all doors and hardware. Contractor shall verify doors for salvage or relocation prior to commencing demolition.

4 Remove existing ceiling system, supports, ties, and related equpiment within room.

Coordinate with electrical work on removal and/ or relocation of lights, conduit, ties, supports, and related wiring. Coordinate with mechanical on removal of diffusers, grills and related ductwork and equipment. Contractor shall verify fixtures for salvage or relocation prior to commencing demolition.Protect existing equipment from dust and damage.

5 Remove existing lighting and all ceiling mounted fixtures within limits of construction unless noted otherwise, including fixture, housing, and all associated wiring and conduit. See MEP drawings for additional information.

6 Remove plumbing fixtures. Cap all plumbing lines not required by new construction.

Coordinate with plumbing plans for additional information. Remove all accessories associated with plumbing fixture.

7 Remove EXIST floor finish and base from entire room to top of structural slab or subfloor as REQ’D for new construction. Patch and level EXIST floor to receive new finish as scheduled. Level per new floor finish MANUF recommendations. Patch EXIST walls as REQ’D to receive new finish as scheduled.

8 Remove existing base from entire room; Patch existing walls as REQD to receive scheduled base.

9 Remove EXIST condensing units and associated rails and/or roof curbs. Patch to match existing roofing

10 Remove existing window unit, including associated trim and hardware. Prepare remaining opening for new construction.

11 Contractor shall remove and dispose of existing desks, shelving and cabinets. (All of which may not be shown on the DEMO Plan)

12 Contractor shall remove and dispose of existing fencing system in it's entirety; Patch floor to accept scheduled floor finish.

13 Contractor shall remove and salvage existing fencing system as REQD for scheduled flooring installation; Replace after new flooring installation has been completed.

GENERAL DEMOLITION NOTES

A Refer to specifications section 02 41 00 - Demolition for additional requirements and information.

B Project Scope line is indicated for general intent only. Additional demolition will be REQ'D outside of this line. Architectural demolition drawings are for schematic purposes. Contractor shall COORD all demolition with the entire set of contract documents for full scope of demolition work REQ'D for the project.

C EXIST conditions shown on these drawings are not guaranteed to be complete. The contractor shall verify all EXIST conditions, dimensions, and materials REQ'D for the contracted work. Report all discrepencies to architect prior to fabrication, erection, and/or installation.

D COORD all new penetrations and/or openings with other associated trades.

E The Owner may select and tag items for demolition to be salvaged. The contractor shall remove selected items and deliver to the Owner's requested…