This is a fire protection equipment inventory document prepared by Collin County, Texas for the Fire Alarm and Fire Sprinkler Inspections, Testing, Maintenance and Repairs solicitation (IFB 2026-298). The exhibit lists detailed fire alarm and sprinkler system equipment across approximately 25 county facilities located in McKinney, Plano, Frisco, and Lavon, Texas. The equipment inventory includes fire alarm panel manufacturers (primarily EST and KIDDE systems), smoke detectors, heat detectors, duct detectors, pull stations, horns, strobes, combination devices, tamper switches, flow switches, fire phones, fire dampers, smoke dampers, bells, door closers, audio visual devices, batteries, fire pumps, wet and dry sprinklers, special sprinkler systems with agents, storage tanks, roof hatches, preaction control panels, Vesta/Modular laser fire curtains, and other ancillary fire protection components. Major facilities include the Justice Center (6 panels), Courthouse, Central Plant, Juvenile Detention Center, Animal Shelter, Administration Building, and various sub-courthouse locations. The document provides specific equipment quantities for each building to establish baseline conditions for maintenance, repairs, and inspection services required under the contract.
The equipment list serves as the basis for determining scope of work, maintenance requirements, and pricing structure for the contract term of 12 consecutive months commencing upon award with three optional one-year renewals. With an estimated annual contract value of $152,000 based on approximately 25 sprinkler inspections and 15 fire alarm system inspections, the pricing structure encompasses lump sum fees for inspections and testing by building, hourly rates for maintenance and repair services during business hours and after-hours periods, and a percentage mark-up on parts. Contractors must hold minimum five years of state licensure in fire protection systems, with fire alarm contractors required to provide Edwards EST factory certification for all technicians and fire sprinkler contractors required to hold Sprinkler Certificate of Registration and appropriate technician licenses. Required bonds include performance bonds of 100% of contract value and payment bonds of 100% for contracts exceeding specified thresholds, due within 10 days of award.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit A - Revised 11.10.26 Fire Alarm and Sprinkler Equipment List
Building FI R
E A
L A
R M
PA
N E
L
A
N U
FA
C
T U
R E
R
SM
O
K E
D E
T E
C T
O R
H E
A T
D E
T E
C T
O R
D U
C T
D E
T E
C T
O R
PU
L
L S
T A
T
IO
N
H O
R N
S T
R O
B
C
O M
B
IN
A T
IO
N
T A
M
PE
R S
W
IT
C H
FL
O
W S
W
IT
C H
FI
R
E P
H O
N E
FI
R
E D
A M
PE
R
SM
O
K E
D A
M
PE
R
B E
L L
H O
R N
D O
O R
C L
O
SE
R
A U
D
IO
V
IS
U A
L
B A
T T
E R
Y
FI
R
E P
U M
P
SP
R
IN
K
L E
R -W
E T
SP
R
IN
K
L E
R -D
R Y
SP
E
C
IA
SP
IN
K
L
SY
ST
E M
A G
E N
T S
T O
R A
G
T
N
K
R O
O F
H A
T C
H
PR
E
A C
T
IO
N T
R O
L P
A N
E L
V E
ST
A
/M O
D U
L A
SE
R
FI
R
E C
U R
T A
IN
S
Central Plant 4600 Community Ave.
McKinney, TX 75071 (1 Panel) EST 4 7 3 2 15 0 3 2 0 0 0 0 0 25 0 2 0 2 0 N/A 0 0 0 0 0
Justice Center 4300 Community Ave.
McKinney, TX 75071 (6 Panels)
EST 4,
EST 3,
& Potter
PFC-
607R 1228 14 84 121 171 47 57 0 24 24 30 10 27 0 61 1 24 0
(15) PRE-
ACTION 0 0 4
Modu laser 2
Juvenile Detention 4700 Community Ave.
McKinney, TX 75071 EST 3 140 4 7 21 2 7 2 0 3 3 2 2 4 0 8 0 2 0
(1) ANTI-
FREEZE 0 0 0 0 0
JJAEP
4690 Community Ave.
McKinney, TX 75071 EST 3 63 0 10 4 1 2 2 0 2 2 1 1 2 N/A 8 0 2 0 N/A 0 0 0 0 0 Minimum Security 4800 Community Ave.
McKinney, TX 75071 EST 3 90 19 15 14 2 5 5 0 4 4 1 1 4 11 8 0 3 1 N/A 0 0 0 0 0 Animal Shelter 4750 Community Ave.
McKinney, TX 75071 (1 Panel) EST 3 19 1 1 10 1 1 1 0 1 1 1 1 1 0 4 0 1 0 N/A 0 0 0 0 0 Administration Building 2300 Bloomdale Rd.
McKinney, TX 75071 (1 Panel) EST 3 58 4 18 1 1 8 6 5 16 90 3 3 4 0 14 1 6 0 N/A 0 0 0 0 0 Courthouse 2100 Bloomdale Rd.
McKinney, TX 75071
EST 3
KIDDE 211 21 21 19 17 33 26 0 12 15 4 4 8 17 48 1 18 4
PRE-
ACTION 3 6 0
Vesta 0 Public Works 700 A Wilmeth Rd McKinney, TX 75069 EST 3 11 3 0 10 1 0 0 0 1 1 1 1 1 0 2 0 0 0 N/A 0 0 0 0 0
Attachment A-Revision 1 Fire Alarm and Sprinkler Equipment List
Building FI R
E A
L A
PA
N U
FA
C
T U
R E
R
SM
O
K E
D E
T E
C T
O R
H E
A T
D E
T E
C T
O R
D U
C T
D E
T E
C T
O R
PU
L
L S
T A
T
IO
N
H O
R N
S T
R O
B
M
B
IN
A T
IO
N
T A
M
PE
R S
W
IT
C H
FL
O
W S
W
IT
C H
FI
R
E P
H O
N E
FI
R
E D
A M
PE
R
SM
O
K E
D A
M
PE
R
B E
L L
H O
R N
D O
O R
C L
O
SE
R
A U
D
IO
V
IS
U A
L
B A
T T
E R
Y
FI
R
E P
U M
P
SP
R
IN
K
L E
R -W
E T
SP
R
IN
K
L E
R -D
R Y
SP
E
C
IA
SP
IN
K
L
SY
ST
E M
A G
E N
T S
T O
R A
G
T
N
K
R O
O F
H A
T C
H
PR
E
A C
T
IO
N T
R O
L P
A N
E L
V E
ST
A
/M O
D U
L A
SE
R
FI
R
E C
U R
T A
IN
S
Medical Examiner Office 700 B Wilmeth Rd.
McKinney, TX 75069 EST 3 5 0 3 5 1 1 1 0 1 1 1 1 1 0 5 0 1 0 N/A 0 0 0 0 0 Health Care Annex 825 N. McDonald St.
McKinney, TX 75069 EST 3 83 0 24 12 1 2 2 0 1 1 1 1 1 0 8 0 2 0 N/A 0 0 0 0 0 Myers Park
7117 CR 166
McKinney, TX 75071 EST 3 15 1 0 4 0 0 0 0 0 0 0 0 0 13 2 0 0 0 N/A 0 0 0 0 0 Plano 900 Bldg.
900 E. Park Blvd.
Plano, TX 75074 EST 3 67 1 5 29 1 3 1 0 20 12 3 3 4 0 14 0 1 0 N/A 0 0 0 0 0 Plano 920 Bldg.
920 E. Park Blvd.
Plano, TX 75074 EST 4 45 1 0 9 1 1 1 0 12 6 2 2 2 0 3 0 1 0 N/A 0 0 0 0 0 Frisco Sub-Courthouse 8585 John Wesley Dr.
Frisco, TX 75035 EST 3 4 0 0 4 0 0 1 0 0 0 4 4 1 0 5 0 1 0
(1) ANTI-
FREEZE 0 0 0 0 0
Lavon Sub-Courthouse 1205 S. State Highway 78 Lavon, TX 75166 EST 3 8 0 0 2 10 0 0 0 0 0 0 0 0 12 2 0 0 0 N/A 0 0 0 0 0
*Combined Justice Center and Central Plant