TP09 Final Drawings 02 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Abatement.pdf

PDF 4 MB Posted

Attached to
Y1DZ--657A4-20-700, EHRM INFRASTRUCTURE UPGRADES
Solicitation number
36C25521R0103
Issued by

About this file

This federal solicitation is for construction services associated with an EHRM Infrastructure Upgrade project at the John J. Pershing VA Medical Center located in Poplar Bluff, Missouri. Work includes constructing a new fiber backbone, server room, and renovating IT closets to include room modifications, HVAC cooling and controls, cabling upgrades, and additional power and data drops. The period of performance is estimated at 365 calendar days from notice to proceed. The principal NAICS code is 236220 for commercial and institutional building construction. The Department of Veterans Affairs Veterans Health Administration VISN 15 is the issuing agency.

View the file

Other files

File Type Posted
S02 36C25521R0103 0008.pdf PDF
Additional RFI (EHRM).pdf PDF
Wage Determination (9-3-2021).pdf PDF
S02 36C25521R0103 0007.pdf PDF
36C25521R0103 0006.pdf PDF
020-2333 EHRM Geotech Report 111020.pdf PDF
36C25521R0103 0005.pdf PDF
S06 36C25521R0103 0002.pdf PDF
657A4-20-700 EHRM Infrastructure Upgrades 36C25521R0103 0001.pdf PDF
S06 36C25521R0103 0003.pdf PDF
S06 36C25521R0103 0004.pdf PDF
SIGN IN ROSTER (657A4-20-700) EHRM INFRASTRUCTURE UPGRADES.pdf PDF
TP09 Final Specs Vol-01.pdf PDF
00 VA OEHRM Site Infrastructure Requirements - 2 Signed.pdf PDF
EHRM NCO15 Price Estimate Template V1.2.url.xlsx XLSX spreadsheet
S02 36C25521R0103_2.pdf PDF
TP09 Final Drawings 10 657A4-20-700 Resubmitted SS 100 percent CD Drawings Technology.pdf PDF
TP09 Final Drawings 09 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Electrical.pdf PDF
TP09 Final Drawings 08 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Mechanical.pdf PDF
TP09 Final Drawings 01 657A4-20-700 Resubmitted SS 100 percent CD Drawings-General.pdf PDF
TP09 Final Drawings 05 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Architectural.pdf PDF
TP01 Specs Vol-02.pdf PDF
TP01 Specs Vol-01.pdf PDF
TP09 Final Drawings 04 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Structural.pdf PDF
36C25521R0103.pdf PDF
TP09 Final Drawings 03 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Civil.pdf PDF
TP09 Final Drawings 06 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Fire Protection.pdf PDF
TP09 Final Drawings 07 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Plumbing.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

1-HA-000

CDJR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

GENERAL COMMENTS

1. ALL ACM ABATEMENT OR ENCLOSURE WORK

SHALL BE PERFORMED BY PROPERLY

TRAINED/LICENSED ASBESTOS ABATEMENT

CONTRACTOR WITHIN A FULL CONTAINMENT

UNDER NEGATIVE PRESSURE (NPE).

2. ALL HVAC AIR INTAKES WITHIN NPE SHALL BE

SHUT DOWN AND ISOLATED WITH CRITICAL

BARRIERS DURING ACTIVE ACM REMOVAL OR

ENCLOSURE WORK. WORK TO BE SCHEDULED WITH

GENERAL CONTRACTOR AND OWNER TO

ACCOMMODATE CONSTRUCTION AND FACILITY

REQUIREMENTS.

3. WORKERS PERFORMING ACM REMOVAL OR

ENCLOSURE SHALL DON, AT MINIMUM, HALF FACE

AIR PURIFYING RESPIRATORS WITH P100 FILTERS,

DISPOSABLE DUST SUITS (WITH BOOT COVERS)

AND GLOVES DURING ACTIVE TASKS, WHICH SHALL

BE SUPPLEMENTED WITH USE OF POWERED AIR

PURIFYING RESPIRATORS.

4. ACM REMOVAL WORK AREAS SHALL BE

PREPARED IN ACCORDANCE WITH THE FOLLOWING:

A) ALL FLOORS, CEILINGS AND WALLS SHALL BE

ISOLATED USING 2-LAYERS OF 6-MIL POLY

SHEETING; B) OSHA ASBESTOS SIGNAGE AT

ENTRANCE TO REGULATED AREAS; C)

SINGLE-POINT OF ENTRY WITH 3-STAGE WET

DECONTAMINATION STATION TO ALLOW WORKERS

TO REMOVE PPE, WASH AND VACUUM THEMSELVES

OFF PRIOR TO EXITING THE REGULATED WORK

AREA; D) MAINTAINED UNDER NEGATIVE PRESSURE

(-0.02 IN WG OR BETTER) USING HEPA FILTERED AIR

MACHINES WITH EXHAUST ROUTED TO OUTDOORS;

E) MINIMUM OF 4 AIR CHANGES PER HOUR; F)

CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS

TO CHANGE INTO STREET CLOTHES (OPAQUE POLY

REQUIRED AS NEEDED FOR PRIVACY); G)

RENEWABLE ADHESIVE MATS IMMEDIATELY

OUTSIDE OF REGULATED WORK AREA TO ENSURE

FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO

OTHER AREAS OF FACILITY.

5. ACM WORK TO BE PERFORMED USING THE

FOLLOWING CONTROLS: A) HEPA FILTERED

VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B)

ONLY MANUAL REMOVAL MEANS/TOOLS ARE

ALLOWED TO DISTURB ACM (MECHANICAL TOOLS

PROHIBITED FOR ACM REMOVAL).

6. REGULATED WORK AREA IS TO BE CLEANED BY

CONTRACTOR FOLLOWING COMPONENT REMOVAL

USING STANDARD HEPA VACUUM & WET WIPING

METHODS AND VISUALLY INSPECTED AND

CLEARANCE SAMPLED BY VA REPRESENTATIVE TO

VERIFY COMPLETION OF SCOPE.

7. VPIH IS TO BE RESPONSIBLE FOR PERIMETER AIR

MONITORING AND FINAL CLEARANCE AIR

SAMPLING/VISUAL INSPECTION REQUIREMENTS.

8. CONTRACTOR TO BE RESPONSIBLE FOR OSHA

EMPLOYEE EXPOSURE MONITORING

REQUIREMENTS.

9. ALL WASTE PRODUCED DURING REMEDIATION

PHASE SHALL BE COLLECTED, CONTAINERIZED,

LABELED, CHARACTERIZED AND DISPOSED IN

ACCORDANCE WITH SPECIFICATION 02.82.11

10. ALL WASTE CONTAINERS, EQUIPMENT, ETC.

SHALL BE WET WIPED PRIOR TO LEAVING

REGULATED WORK AREA.

11. CRAWLSPACE IS TO BE CONSIDERED A

CONFINED SPACE. PROVIDE FOR EMERGENCY

RESPONSE PROTOCOL, CONSTANT

COMMUNICATION WITH HOLE WATCH, AND

EMERGENCY EXTRACTION PROCEDURES.

IMPLEMENT ALL PROCEDURES OF OSHA 1910. 146

KEYED NOTES

REMOVE ASBESTOS INSULATION AND ASSOCIATED

MUDDED FITTINGS USING GLOVEBAG METHODS

WITHIN NEGATIVE PRESSURE CONTAINMENT, 130

FT OF ASBESTOS TAR & CORK PIPE INSULATION

AND MUDDED FITTINGS, 14" DIAMETER.

APPROXIMATELY 1,200 SF OF ASBESTOS

CONTAMINATED CRAWLSPACE SOIL IS TO BE FULLY

ENCLOSED WITHIN A LARGER CRAWL SPACE WITH

CONTAMINATED SOILS. REMOVE VISIBLE DEBRIS

WHERE PRESENT. ENCLOSURE BOUNDARY SHALL

CONSIST OF AIR TIGHT SEPARATION WALL,

INSTALLATION OF A 60 MILLIMETER THICK EPDM

MEMBRANE OVER EXPOSED SOIL SURFACE, WITH

MEMBRANE SHEETS CHEMICALLY WELDED AT

SEAMS (WITH 12" OVERLAP AT ALL SEAMS), AND

PHYSICALLY SEALED ALONG PERIMETER EDGES

(I.E. FURRING STRIPS AND TAP-CONS WITH

MEMBRANE FOLDED OVER) TO CONCRETE WALLS

AND/OR COLUMNS, AS NEEDED TO ENSURE AN

AIR-TIGHT LAYER IS ACHIEVED AND MAINTAINED

BETWEEN SOILS AND CRAWL SPACE. PROVIDE AIR

TIGHT BOUNDARY WALL (60LF) AND 1,200 SF OF

COVER SYSTEM WITH EDGE SEALS. PERFORM

WORK WITHIN NEGATIVE PRESSURE ENCLOSURE.

RIGOROUS PRE-CLEANING BY HEPA VACUUM AND

MANUAL WIPING OF ALL SURFACES WILL BE

NECESSARY TO ACHIEVE CLEARANCE.

USING MANUAL MEANS WITHIN A NEGATIVE

PRESSURE CONTAINMENT, CLEAN DIRT FROM

EXCAVATED FOUNDATION WALL AND APPLY BOND

BREAKER PROVIDED BY OTHERS. PROTECT

ASBESTOS BLACK WATERPROOFING AND APPLY

ASBESTOS IDENTIFICATION LABELS, 10 LABELS, 12

CUBIC FEET ON WASTE EARTH, 125 SF OF

ASBESTOS WATER PROOFING CLEANING AND BOND

BREAKER APPLICATION.

REMOVE DAMAGED ASBESTOS MUDDED FITTINGS

AND PIPE INSULATION USING GLOVEBAG METHODS

WITHIN A NEGATIVE PRESSURE CONTAINMENT, 3

FITTINGS AND 14LF OF ASBESTOS PIPE INSULATION.

REMOVE DAMAGED ASBESTOS MUDDED FITTINGS

AND ASBESTOS TAR AND CORK PIPE INSULATION

USING GLOVEBAG METHODS WITHIN A NEGATIVE

PRESSURE CONTAINMENT, 20 FITTINGS, 2

CONTAINMENTS, AND 12LF OF PIPE INSULATION

ASBESTOS CONTAMINATED DIRT CRAWLSPACE

PRESENT, PROTECT AS NECESSARY

DO NOT DISTURB ASBESTOS BLACK TAR

WATERPROOFING ON EXTERIOR FOUNDATION

WALL WHERE PRESENT, USE EXISTING SLEEVES.

CONDITION OF ASBESTOS PIPE INSULATION WAS

NOT INSPECTED DUE TO OFF LIMITS FOR ENTRY.

FIBER OPTIC CABLE ROUTING PATHWAY.

A1

A2

A3

A4

A5

A6

A7

A8

ST

AI

RW

EL

L

A3 A7

A2 A1

General Contractor to Provide A

Sealed Metal Stud Barrier Wall

Complete With Lockable Access

Port and 60Millimter Thick EDPM membrane

ASBESTOS WATERPROOFING

PRESENT BELOW GRADE ON

PERIMETER BUILDING WALLS

A4

A7

A7

A8

A6

A6

A6

A7

A7

A7

A5

N

BASEMENT

VISUAL KEY

NEGATIVE PRESSURE ENCLOSURE (NPE)

HEPA FILTERED NEGATIVE AIR MACHINES WITH SUGGESTED TUBING DIRECTION

3 STAGE WET DECONTAMINATION STATION (WITH SHOWER)

2 STAGE WASTE LOAD OUT CHAMBER

HATCHING KEY

ASBESTOS PIPE INSULATION AND/OR MUDDED

FITTINGS

ASBESTOS CONTAMINATED CRAWLSPACE SOIL

ASBESTOS BLACK TAR WATERPROOFING ON

EXTERIOR FOUNDATION WALL

AREA OF EDPM ENCLOSURE OVER ASBESTOS

CONTAMINATED SOIL

BLDG 1 BASEMENT

ENVIRONMENTAL HAZARDS

CIH NO. 8594 CP

03/23/21 r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

1-HA-G00

CDJR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

BLDG 1 GROUND FLOOR

ENVIRONEMNTAL HAZARDS

KEYED NOTES

REMOVE WINDOW SYSTEM WITH HIDDEN AND

VISIBLE ASBESTOS CAULKS AND GLAZING WITHIN A

NEGATIVE PRESSURE CONTAINMENT USING

ABATEMENT METHODS AS REQUIRED BY SECTION

02.82.11 - (4 ASSEMBLIES, 2 NPE). PERFORM WORK

NIGHTS AND WEEKENDS IN ROOMS 55 & 56.

REMOVE NON-ASBESTOS PLASTER CHASE,

DRYWALL CHASE AND ASSOCIATED COVERINGS.

THEN REMOVE ASBESTOS PIPE INSULATION USING

GLOVEBAG METHODS IN A NEGATIVE PRESSURE

CONTAINMENT, 60 SF OF PLASTER & 30 LF PIPE

INSULATION.

REMOVE NONASBESTOS CEILING TILES THEN

ASBESTOS PIPE INSULATION AND FITTINGS ABOVE

WINDOW ASSEMBLIES USING GOVEBAG METHODS

WITHIN A NEGATIVE PRESSURE CONTAINMENT,

80LF. PERFROM WORK NIGHTS AND WEEKENDS IN

ROOMS 55 & 56.

WITHIN A NEGATIVE PRESSURE CONTAINMENT

REMOVE RAISED FLOOR PEDESTALS, THEN

ASBESTOS FLOOR TILE AND UNDERLYING

ASBESTOS BLACK MASTIC, 230 PEDESTALS AND

375SF FLOOR TILES AND ASSOCIATED ASBESTOS

MASTIC, 2 CONTAINMENTS.

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS AND ON NIGHTS AND

WEEKENDS, REMOVE CONTAMINATED CEILING

TILES AND DISPOSE, APPLY TWO LAYERS OF

COVERING LAG CLOTH OVER DAMAGE/DEFECTS, 13

CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT, 3,250 SF CEILING TILES

REMOVE CONTAMINATED CEILING TILES AND

ASBESTOS PIPE INSULATION AND FITTINGS ON

NIGHTS AND WEEKENDS WITHIN A NEGATIVE

PRESSURE CONTAINMENT, 100SF CEILING TILES, 15

LF OF PIPE INSULATION AND ASSOCIATED MUDDED

FITTINGS..

BROWN/TAN ASBESTOS DRYWALL ADHESIVE

PRESENT ON METAL DRYWALL FURRING STRIPS,

DRYWALL, AND/OR CERAMIC WALL BLOCKS

UNDERLYING DRYWALL DECORATIVE FACE,

LOCATED THROUGHOUT CORRIDORS, PROTECT AS

NECESSARY.

REMOVE ASBESTOS TRANSITE PANEL AND/OR TAR

COATED ENCLOSURE BEHIND WALL FACING, 15 SF

DAMAGED ASBESTOS PIPE INSULATION PRESENT.

DO NOT PERFORM WORK IN THIS AREA, PROTECT

AS NECESSARY.

DO NOT DISTURB ASBESTOS BLACK TAR

WATERPROOFING ON EXTERIOR FOUNDATION

WALL WHERE PRESENT. USE EXISTING SLEEVES.

ASBESTOS BLACK TAR WATERPROOFING ON

FOUNDATION WALLS WITHIN CRAWLSPACE,

PROTECT AS NECESSARY.

ASBESTOS CONTAMINATED DIRT CRAWLSPACE

PRESENT, PROTECT AS NECESSARY

DO NOT DISTURB BLOCK OR PLASTER CHASES

WITH ASBESTOS PIPE INSULATION, PROTECT AS

NECESSARY. USE NON INVASIVE SURFACE MOUNT

WALL DATA JACK SYSTEM WITH MASTIC OR

SIMILAR. PERFORM WORK NIGHTS AND WEEKENDS

IN ROOMS 55 & 56.

REMOVE LBP WINDOW ASSEMBLY USING

ABATEMENT METHODS WITHIN A NEGATIVE

PRESSURE CONTAINMENT AS REQUIRED BY

SECTION 02.83.13.13 - 1 ASSEMBLY

LEAD CONTAINING CERAMIC WALL BLOCKS ARE

PRESENT BEHIND DRYWALL IN CORRIDOR, DO NOT

DISTURB AND PROTECT AS NECESSARY.

A1

GENERAL COMMENTS

1. ALL ACM ABATEMENT OR ENCLOSURE WORK

SHALL BE PERFORMED BY PROPERLY

TRAINED/LICENSED ASBESTOS ABATEMENT

CONTRACTOR WITHIN A FULL CONTAINMENT

UNDER NEGATIVE PRESSURE (NPE).

2. ALL HVAC AIR INTAKES WITHIN NPE SHALL BE

SHUT DOWN AND ISOLATED WITH CRITICAL

BARRIERS DURING ACTIVE ACM REMOVAL OR

ENCLOSURE WORK. WORK TO BE SCHEDULED WITH

GENERAL CONTRACTOR AND OWNER TO

ACCOMMODATE CONSTRUCTION AND FACILITY

REQUIREMENTS.

3. WORKERS PERFORMING ACM REMOVAL OR

ENCLOSURE SHALL DON, AT MINIMUM, HALF FACE

AIR PURIFYING RESPIRATORS WITH P100 FILTERS,

DISPOSABLE DUST SUITS (WITH BOOT COVERS)

AND GLOVES DURING ACTIVE TASKS, WHICH SHALL

BE SUPPLEMENTED WITH USE OF POWERED AIR

PURIFYING RESPIRATORS.

4. ACM REMOVAL WORK AREAS SHALL BE

PREPARED IN ACCORDANCE WITH THE FOLLOWING:

A) ALL FLOORS, CEILINGS AND WALLS SHALL BE

ISOLATED USING 2-LAYERS OF 6-MIL POLY

SHEETING; B) OSHA ASBESTOS SIGNAGE AT

ENTRANCE TO REGULATED AREAS; C)SINGLE-POINT

OF ENTRY WITH 3-STAGE WET DECONTAMINATION

STATION TO ALLOW WORKERS TO REMOVE PPE,

WASH AND VACUUM THEMSELVES OFF PRIOR TO

EXITING THE REGULATED WORK AREA; D)

MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN

WG OR BETTER) USING HEPA FILTERED AIR

MACHINES WITH EXHAUST ROUTED TO OUTDOORS;

E) MINIMUM OF 4 AIR CHANGES PER HOUR; F)

CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS

TO CHANGE INTO STREET CLOTHES (OPAQUE POLY

REQUIRED AS NEEDED FOR PRIVACY); G)

RENEWABLE ADHESIVE MATS IMMEDIATELY

OUTSIDE OF REGULATED WORK AREA TO ENSURE

FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO

OTHER AREAS OF FACILITY.

5. ACM WORK TO BE PERFORMED USING THE

FOLLOWING CONTROLS: A) HEPA FILTERED

VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B)

ONLY MANUAL REMOVAL MEANS/TOOLS ARE

ALLOWED TO DISTURB ACM (MECHANICAL TOOLS

PROHIBITED FOR ACM REMOVAL).

6. REGULATED WORK AREA IS TO BE CLEANED BY

CONTRACTOR FOLLOWING COMPONENT REMOVAL

USING STANDARD HEPA VACUUM & WET WIPING

METHODS AND VISUALLY INSPECTED AND

CLEARANCE SAMPLED BY VA REPRESENTATIVE TO

VERIFY COMPLETION OF SCOPE.

7. VPIH IS TO BE RESPONSIBLE FOR PERIMETER AIR

MONITORING AND FINAL CLEARANCE AIR

SAMPLING/VISUAL INSPECTION REQUIREMENTS.

8. CONTRACTOR TO BE RESPONSIBLE FOR OSHA

EMPLOYEE EXPOSURE MONITORING

REQUIREMENTS.

9. ALL WASTE PRODUCED DURING REMEDIATION

PHASE SHALL BE COLLECTED, CONTAINERIZED,

LABELED, CHARACTERIZED AND DISPOSED IN

ACCORDANCE WITH SPECIFICATION 02.82.11

10. ALL WASTE CONTAINERS, EQUIPMENT, ETC.

SHALL BE WET WIPED PRIOR TO LEAVING

REGULATED WORK AREA.

11. NIGHTS WORK IS TO BE PERFORMED DURING

OFF HOURS FROM 5:00 PM - 7:00 AM MONDAY

THROUGH FRIDAY AND WEEKEND WORK FRIDAY 6

PM THROUGH SUNDAY. WORK IS PROHIBITED ON

FEDERAL HOLIDAYS.

12. ASBESTOS RELATED MATERIALS ARE PRESENT

AND MAY NOT SHOWN ON DRAWINGS FOR CLARITY.

KNOWN ASBESTOS MATERIALS INCLUDE FIRE

DOORS, SOILS, DOOR AND WINDOW CAULKS,

WINDOWS GLAZING, FLOOR TILE GROUPS AND

ASSOCIATED UNDERLYING ASBESTOS MASTIC,

FOUNDATION WATERPROOFING, TRANSITE AT

WINDOW CONVECTORS, ASBESTOS DRYWALL

ADHESIVES WHERE APPLIED TO WALL BLOCKS,

GREEN MARBLE WALL PANELS, ACOUSTICAL LOBBY

PLASTER, BLACK OR WHITE DUCT SEAM SEALANTS

AND APPLICATIONS, SINK SOUND PROOFING,

VIBRATION ISOLATION DUCT JOINTS, ASBESTOS

PIPE INSULATION AND MUDDED FITTINGS, AND

GALBESTOS COATED DUCTWORK. PROTECT AS

NECESSARY.

13. AT INTERIOR REGULATED AREAS (NPE), WHERE

THE COMBINED FOOTPRINT OF WORK CHAMBER,

DECONTAMINATION CHAMBERS AND LOADOUT

DOES NOT FIT WITHIN THE ROOM, THE

DECON/LOADOUT CONFIGURATION MAY EXTEND

INTO 1/2 WIDTH OF THE HALLWAY AS REQUIRED TO

ALLOW PASSAGE IN CORRIDOR.

VISUAL KEY

ASBESTOS PIPE INSULATION AND/OR MUDDED

FITTINGS

ASBESTOS CONTAMINATED CRAWLSPACE SOIL

A2

A3

A4

A5

A6

A7

A8

A9

A10

L1

L2

A11

A12

A13

UP

UP

UP

UP

UP

UP

UP

UP

UP

DN

01A

01C

07A

07B

07C

07D

07E

07F

07G

07H

07I

07J

07K

07L

07M

07N

07O

07Q

07R

07S

09A

18A

17A

17B

17C

GSTAIR

GSTAIR

09B

10A

10B

10C

11A

14A

15A

16A

GB

GSTAIR

01B

GSTAIR

44A

44B

45A

47A

01D

GD

GA1

60A

60B

60C

GG/GP1

66A

68A

GSTAIR

79A

GE

R A

M P

07T

FE

FE

FE

FE

FE

FE

FE

A5

A5

A5

A7

A7

A5

A5

L2

L2

A2 A3 A4

A1 L1

A5

A7

A7

A5

A9

A7

A7

A9

A9

A9

A5

A5

A5

A6

A5

A5

A7

A7

ASBESTOS BROWN/TAN

ADHESIVE ON DRYWALL

SYSTEM OVER HISTORIC

CERAMIC BLOCK OR PLASTER

WALLS, THROUGHOUT

CORRIDORS

A5

A8

A12

A11

A13 A13

A7

A13

A13

A13

A13

A13

A2 A3

A1 L1 A8

A4

N

GROUND FLOOR

r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

1-HA-G01

CDJR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

A5

A5

A5

A5

A5

A5

09A

A5

44B

A5

11A

A5

VISUAL KEY

NEGATIVE PRESSURE ENCLOSURE (NPE)

HEPA FILTERED NEGATIVE AIR MACHINES WITH SUGGESTED TUBING DIRECTION

3 STAGE WET DECONTAMINATION STATION (WITH SHOWER)

2 STAGE WASTE LOAD OUT CHAMBER

KEYED NOTES

WITHIN A NEGATIVE PRESSURE CONTAINMENT

REMOVE RAISED FLOOR PEDESTALS, THEN

ASBESTOS FLOOR TILE AND UNDERLYING

ASBESTOS BLACK MASTIC, 230 PEDESTALS AND

375SF FLOOR TILES AND ASSOCIATED ASBESTOS

MASTIC, 2 CONTAINMENTS.

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS, REMOVE

CONTAMINATED CEILING TILES, APPLY TWO LAYERS

OF COVERING LAG CLOTH OVER DAMAGE/DEFECTS,

15 CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT, 3,500 SF CEILING TILES

A5

A5

A5

UP

GSTAIR

44A

A5

A4

A5

A4

N

GROUND FLOOR

BLDG 1 GROUND FLOOR

CONTAINMENT DETAILS

r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-100

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

N

1ST FLOOR

DN

DN

DN

DN

DN

DN

DN

DN

DN

UP

UP

10001001 1002

1007A

1STAIR

1009A

1011 1012

1STAIR

1STAIR

B

1025A

1027A

1030 1031 1032

1B

1STAIR

1STAIR

C

10621063

1060A

1064A

106410651065A

1STAIR

1003A

1068A

1075A

1STAIR

110111021103110411051106

1110A

1110B

1115A

1E

1STAIR

1147 11491A1

1STAIR

1166A

1F

1A3

1D2

1STAIR

A

1C

1130A

FE

FE

FE

FE

FE

FE

FE

A1

A1

A1

A1 A1

A1

A1

A1

A7

A1

A1

A1

A1

L1

L1

L1

A2

A2

L2

ASBESTOS BROWN/TAN

ADHESIVE ON DRYWALL

SYSTEM OVER HISTORIC

CERAMIC BLOCK OR PLASTER

WALLS, THROUGHOUT

CORRIDORS

A2

A2

L2

A3

L1

A3

L1

A4

A5

A6

A3

A5

A3

A5

A3

A3

A2

A2

L2

A2

A3

A2

A3

A3

A3

A3

A3

A3

A3

A3

A3

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS AND ON NIGHTS AND

WEEKENDS, REMOVE CONTAMINATED CEILING

TILES, APPLY TWO LAYERS OF COVERING LAG

CLOTH OVER DAMAGE/DEFECTS, 11

CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT, 2,750 SF CEILING TILES

BROWN/TAN ASBESTOS DRYWALL ADHESIVE

PRESENT ON METAL DRYWALL FURRING STRIPS,

DRYWALL, AND/OR CERAMIC WALL BLOCKS

UNDERLYING DRYWALL DECORATIVE FACE,

LOCATED THROUGHOUT CORRIDORS, PROTECT AS

NECESSARY.

DO NOT DISTURB BLOCK OR PLASTER CHASES

WITH ASBESTOS PIPE INSULATION, PROTECT AS

NECESSARY. USE NON INVASIVE SURFACE MOUNT

WALL DATA JACK SYSTEM WITH MASTIC OR

SIMILAR.

DO NOT DISTURB GREEN MARBLE ASBESTOS WALL

PANELS AND/OR BLOCK CHASE WITH ASBESTOS

INSULATED PIPE. PROTECT AS NECESSARY. USE

NON INVASIVE SURFACE MOUNT WALL DATA JACK

SYSTEM WITH MASTIC OR SIMILAR. DO NOT

PENETRATE ASBESTOS GREEN MARBLE WALL

PANELS AND TRIM.

DO NOT DISTURB ASBESTOS GREEN WALL PANELS

OR TRIM PROTECT AS NECESSARY.

DO NOT DISTURB ASBESTOS PLASTER SURFACING

ON CONCRETE HEADER BEAM. USE EXISTING

PATHWAYS AND SLEEVE.

DAMAGED ASBESTOS PIPE INSULATION PRESENT,

DO NOT PERFORM WORK IN THIS AREA (DO NOT

REMOVE CEILING SYSTEM TILES), PROTECT AS

NECESSARY.

DENOTES REPRESENTATIVE LOCATIONS OF LEAD

CONTAINING CERAMIC WALL BLOCKS, OR LEAD

CONTAINING CERAMIC WALL TILES GENERALLY 4" X

4". WALL BLOCKS ,WHERE NOTED AS LEADED,

APPEAR TO BE OFF COLOR OR PATTERN AND ARE

THOUGHT TO REPRESENT AREAS "OF REPAIR" OR

HAVE BEEN PAINTED (LBP). CERAMIC WALL TILES

ARE GENERALLY PRESENT WHERE SINKS ARE

EXISTING AND ALL LOCATIONS ARE NOT SHOWN

FOR CLARITY PURPOSES. DO NOT DISTURB

CERAMIC WALL TILES AND LEADED CERAMIC WALL

BLOCKS WHERE SHOWN.

DENOTES REPRESENTATIVE LOCATIONS OF LBP

PAINTED PLASTER OR DRYWALL WALLS. DO NOT

DISTURB AND PROTECT AS NECESSARY

A1

VISUAL KEY

ASBESTOS PIPE INSULATION AND/OR MUDDED

FITTINGS

GENERAL COMMENTS

1. ALL ACM ABATEMENT OR ENCLOSURE WORK

SHALL BE PERFORMED BY PROPERLY

TRAINED/LICENSED ASBESTOS ABATEMENT

CONTRACTOR WITHIN A FULL CONTAINMENT

UNDER NEGATIVE PRESSURE (NPE).

2. ALL HVAC AIR INTAKES WITHIN NPE SHALL BE

SHUT DOWN AND ISOLATED WITH CRITICAL

BARRIERS DURING ACTIVE ACM REMOVAL OR

ENCLOSURE WORK. WORK TO BE SCHEDULED WITH

GENERAL CONTRACTOR AND OWNER TO

ACCOMMODATE CONSTRUCTION AND FACILITY

REQUIREMENTS.

3. WORKERS PERFORMING ACM REMOVAL OR

ENCLOSURE SHALL DON, AT MINIMUM, HALF FACE

AIR PURIFYING RESPIRATORS WITH P100 FILTERS,

DISPOSABLE DUST SUITS (WITH BOOT COVERS)

AND GLOVES DURING ACTIVE TASKS, WHICH SHALL

BE SUPPLEMENTED WITH USE OF POWERED AIR

PURIFYING RESPIRATORS.

4. ACM REMOVAL WORK AREAS SHALL BE

PREPARED IN ACCORDANCE WITH THE FOLLOWING:

A) ALL FLOORS, CEILINGS AND WALLS SHALL BE

ISOLATED USING 2-LAYERS OF 6-MIL POLY

SHEETING; B) OSHA ASBESTOS SIGNAGE AT

ENTRANCE TO REGULATED AREAS; C)SINGLE-POINT

OF ENTRY WITH 3-STAGE WET DECONTAMINATION

STATION TO ALLOW WORKERS TO REMOVE PPE,

WASH AND VACUUM THEMSELVES OFF PRIOR TO

EXITING THE REGULATED WORK AREA; D)

MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN

WG OR BETTER) USING HEPA FILTERED AIR

MACHINES WITH EXHAUST ROUTED TO OUTDOORS;

E) MINIMUM OF 4 AIR CHANGES PER HOUR; F)

CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS

TO CHANGE INTO STREET CLOTHES (OPAQUE POLY

REQUIRED AS NEEDED FOR PRIVACY); G)

RENEWABLE ADHESIVE MATS IMMEDIATELY

OUTSIDE OF REGULATED WORK AREA TO ENSURE

FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO

OTHER AREAS OF FACILITY.

5. ACM WORK TO BE PERFORMED USING THE

FOLLOWING CONTROLS: A) HEPA FILTERED

VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B)

ONLY MANUAL REMOVAL MEANS/TOOLS ARE

ALLOWED TO DISTURB ACM (MECHANICAL TOOLS

PROHIBITED FOR ACM REMOVAL).

6. REGULATED WORK AREA IS TO BE CLEANED BY

CONTRACTOR FOLLOWING COMPONENT REMOVAL

USING STANDARD HEPA VACUUM & WET WIPING

METHODS AND VISUALLY INSPECTED AND

CLEARANCE SAMPLED BY VA REPRESENTATIVE TO

VERIFY COMPLETION OF SCOPE.

7. VPIH IS TO BE RESPONSIBLE FOR PERIMETER AIR

MONITORING AND FINAL CLEARANCE AIR

SAMPLING/VISUAL INSPECTION REQUIREMENTS.

8. CONTRACTOR TO BE RESPONSIBLE FOR OSHA

EMPLOYEE EXPOSURE MONITORING

REQUIREMENTS.

9. ALL WASTE PRODUCED DURING REMEDIATION

PHASE SHALL BE COLLECTED, CONTAINERIZED,

LABELED, CHARACTERIZED AND DISPOSED IN

ACCORDANCE WITH SPECIFICATION 02.82.11

10. ALL WASTE CONTAINERS, EQUIPMENT, ETC.

SHALL BE WET WIPED PRIOR TO LEAVING

REGULATED WORK AREA.

11. NIGHTS WORK IS TO BE PERFORMED DURING

OFF HOURS FROM 5:00 PM - 7:00 AM MONDAY

THROUGH FRIDAY AND WEEKEND WORK FRIDAY 6

PM THROUGH SUNDAY. WORK IS PROHIBITED ON

FEDERAL HOLIDAYS.

12. ASBESTOS RELATED MATERIALS ARE PRESENT

AND MAY NOT SHOWN ON DRAWINGS FOR CLARITY.

KNOWN ASBESTOS MATERIALS INCLUDE FIRE

DOORS, SOILS, DOOR AND WINDOW CAULKS,

WINDOWS GLAZING, FLOOR TILE GROUPS AND

ASSOCIATED UNDERLYING ASBESTOS MASTIC,

FOUNDATION WATERPROOFING, TRANSITE AT

WINDOW CONVECTORS, ASBESTOS DRYWALL

ADHESIVES WHERE APPLIED TO WALL BLOCKS,

GREEN MARBLE WALL PANELS, ACOUSTICAL LOBBY

PLASTER, BLACK OR WHITE DUCT SEAM SEALANTS

AND APPLICATIONS, SINK SOUND PROOFING,

VIBRATION ISOLATION DUCT JOINTS, ASBESTOS

PIPE INSULATION AND MUDDED FITTINGS, AND

GALBESTOS COATED DUCTWORK. PROTECT AS

NECESSARY.

13. AT INTERIOR REGULATED AREAS (NPE), WHERE

THE COMBINED FOOTPRINT OF WORK CHAMBER,

DECONTAMINATION CHAMBERS AND LOADOUT

DOES NOT FIT WITHIN THE ROOM, THE

DECON/LOADOUT CONFIGURATION MAY EXTEND

INTO 1/2 WIDTH OF THE HALLWAY AS REQUIRED TO

ALLOW PASSAGE IN CORRIDOR.

A2

A3

A4

A5

A6

A7

L1

L2

BLDG 1 FLOOR ONE ENVIRONMENTAL

HAZARDS

r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-101

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

N

1ST FLOOR

A1

11031104

A1

A1

A1

A1

VISUAL KEY

NEGATIVE PRESSURE ENCLOSURE (NPE)

HEPA FILTERED NEGATIVE AIR MACHINES WITH SUGGESTED TUBING DIRECTION

3 STAGE WET DECONTAMINATION STATION (WITH SHOWER)

2 STAGE WASTE LOAD OUT CHAMBER

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS, REMOVE

CONTAMINATED CEILING TILES, APPLY TWO LAYERS

OF COVERING LAG CLOTH OVER DAMAGE/DEFECTS,

12 CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT - 3000 FT² CEILING TILE.

A1

BLDG 1 FLOOR ONE

CONTAINMENT DETAILS - 1

r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-102

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

N

1ST FLOOR

A1

A1

A1

A1

A1

L2

A1

VISUAL KEY

NEGATIVE PRESSURE ENCLOSURE (NPE)

HEPA FILTERED NEGATIVE AIR MACHINES WITH SUGGESTED TUBING DIRECTION

3 STAGE WET DECONTAMINATION STATION (WITH SHOWER)

2 STAGE WASTE LOAD OUT CHAMBER

BUILDING 1, FIRST FLOOR DRAWING

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS, REMOVE

CONTAMINATED CEILING TILES, APPLY TWO LAYERS

OF COVERING LAG CLOTH OVER DAMAGE/DEFECTS,

12 CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT - 3000 FT² CEILING TILE.

A1

BLDG 1 FLOOR ONE

CONTAINMENT DETAILS - 2

DN

UP

DN

UP

2002A

2005 2006

2STAIR

2018A

2036 2037

2037A

2037B

2STAIR

2C

2042A

2055A

2054A

20592060

20642065

2000A

2STAIR

2C

2STAIR

2070C

2070A

2074A

2D

2075A

2075B

2077A

2077B

2077C

2078A

2078B

2078C

2000B

2D

2097B

2098A

2098B

2E

2109B

2STAIR

2113 21142113A

2A1

2STAIR

2127A

2131 2132

2A

2B

2F

2F

2STAIR

A

2STAIR

B

FE

FE

FE

FE

FE

FE

445' - 7 1/4"

445' - 7 1/4"

446' - 1 1/4"

445' - 7 1/4"

445' - 7 1/4"

445' - 7 1/4"

445' - 7 1/4"

FOLDING

PARTITION

N

2ND FLOOR

A1

A1

A1

A1

L3

A2

A2

A2

A2

A2

A2

L2 L2 L2

L2

A1

A1

L2

A1

A1

A1

L1 L1

L1 A1

L1

L3

L1

L2

L2

L2

A1

A1

L1

A2

L2

L1

L1 A1

L1

L1 A1 L3

L1

L1

L1

L1

L1

A1

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

L3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A2

A2

A3

A3

A3 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-200

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS AND ON NIGHTS AND

WEEKENDS, REMOVE CONTAMINATED CEILING

TILES, APPLY TWO LAYERS OF COVERING LAG

CLOTH OVER DAMAGE/DEFECTS, 14

CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT, 3,500 SF CEILING TILES

BROWN/TAN ASBESTOS DRYWALL ADHESIVE

PRESENT ON METAL DRYWALL FURRING STRIPS,

DRYWALL, AND/OR CERAMIC WALL BLOCKS

UNDERLYING DRYWALL DECORATIVE FACE,

LOCATED THROUGHOUT CORRIDORS, PROTECT AS

NECESSARY.

DO NOT DISTURB BLOCK OR PLASTER CHASES

WITH ASBESTOS PIPE INSULATION, PROTECT AS

NECESSARY. USE NON INVASIVE SURFACE MOUNT

WALL DATA JACK SYSTEM WITH MASTIC OR

SIMILAR.

DRYWALL WALLS WITH LEAD SHIELDING. PROTECT

AS NECESSARY, USE NON INVASIVE SURFACE

MOUNT WALL DATA JACK SYSTEM WITH MASTIC OR

SIMILAR.

DENOTES REPRESENTATIVE LOCATIONS OF LEAD

CONTAINING CERAMIC WALL BLOCKS, OR LEAD

CONTAINING CERAMIC WALL TILES GENERALLY 4" X

4". WALL BLOCKS WHERE NOTED AS LEADED,

APPEAR TO BE OFF COLOR OR PATTERN AND ARE

THOUGHT TO REPRESENT AREAS "OF REPAIR" OR

HAVE BEEN PAINTED (LBP). CERAMIC WALL TILES

ARE GENERALLY PRESENT WHERE SINKS ARE

EXISTING AND ALL LOCATIONS ARE NOT SHOWN

FOR CLARITY PURPOSES. DO NOT DISTURB

CERAMIC WALL TILES AND LEADED CERAMIC WALL

BLOCKS WHERE SHOWN. PROTECT AS NECESSARY.

USE NON INVASIVE SURFACE MOUNT WALL DATA

JACK SYSTEM WITH MASTIC OR SIMILAR.

DENOTES REPRESENTATIVE LOCATIONS OF LBP

PAINTED PLASTER WALLS. DO NOT DISTURB AND

PROTECT AS NECESSARY

A1

GENERAL COMMENTS

1. ALL ACM ABATEMENT OR ENCLOSURE WORK

SHALL BE PERFORMED BY PROPERLY

TRAINED/LICENSED ASBESTOS ABATEMENT

CONTRACTOR WITHIN A FULL CONTAINMENT

UNDER NEGATIVE PRESSURE (NPE).

2. ALL HVAC AIR INTAKES WITHIN NPE SHALL BE

SHUT DOWN AND ISOLATED WITH CRITICAL

BARRIERS DURING ACTIVE ACM REMOVAL OR

ENCLOSURE WORK. WORK TO BE SCHEDULED WITH

GENERAL CONTRACTOR AND OWNER TO

ACCOMMODATE CONSTRUCTION AND FACILITY

REQUIREMENTS.

3. WORKERS PERFORMING ACM REMOVAL OR

ENCLOSURE SHALL DON, AT MINIMUM, HALF FACE

AIR PURIFYING RESPIRATORS WITH P100 FILTERS,

DISPOSABLE DUST SUITS (WITH BOOT COVERS)

AND GLOVES DURING ACTIVE TASKS, WHICH SHALL

BE SUPPLEMENTED WITH USE OF POWERED AIR

PURIFYING RESPIRATORS.

4. ACM REMOVAL WORK AREAS SHALL BE

PREPARED IN ACCORDANCE WITH THE FOLLOWING:

A) ALL FLOORS, CEILINGS AND WALLS SHALL BE

ISOLATED USING 2-LAYERS OF 6-MIL POLY

SHEETING; B) OSHA ASBESTOS SIGNAGE AT

ENTRANCE TO REGULATED AREAS; C)SINGLE-POINT

OF ENTRY WITH 3-STAGE WET DECONTAMINATION

STATION TO ALLOW WORKERS TO REMOVE PPE,

WASH AND VACUUM THEMSELVES OFF PRIOR TO

EXITING THE REGULATED WORK AREA; D)

MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN

WG OR BETTER) USING HEPA FILTERED AIR

MACHINES WITH EXHAUST ROUTED TO OUTDOORS;

E) MINIMUM OF 4 AIR CHANGES PER HOUR; F)

CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS

TO CHANGE INTO STREET CLOTHES (OPAQUE POLY

REQUIRED AS NEEDED FOR PRIVACY); G)

RENEWABLE ADHESIVE MATS IMMEDIATELY

OUTSIDE OF REGULATED WORK AREA TO ENSURE

FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO

OTHER AREAS OF FACILITY.

5. ACM WORK TO BE PERFORMED USING THE

FOLLOWING CONTROLS: A) HEPA FILTERED

VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B)

ONLY MANUAL REMOVAL MEANS/TOOLS ARE

ALLOWED TO DISTURB ACM (MECHANICAL TOOLS

PROHIBITED FOR ACM REMOVAL).

6. REGULATED WORK AREA IS TO BE CLEANED BY

CONTRACTOR FOLLOWING COMPONENT REMOVAL

USING STANDARD HEPA VACUUM & WET WIPING

METHODS AND VISUALLY INSPECTED AND

CLEARANCE SAMPLED BY VA REPRESENTATIVE TO

VERIFY COMPLETION OF SCOPE.

7. VPIH IS TO BE RESPONSIBLE FOR PERIMETER AIR

MONITORING AND FINAL CLEARANCE AIR

SAMPLING/VISUAL INSPECTION REQUIREMENTS.

8. CONTRACTOR TO BE RESPONSIBLE FOR OSHA

EMPLOYEE EXPOSURE MONITORING

REQUIREMENTS.

9. ALL WASTE PRODUCED DURING REMEDIATION

PHASE SHALL BE COLLECTED, CONTAINERIZED,

LABELED, CHARACTERIZED AND DISPOSED IN

ACCORDANCE WITH SPECIFICATION 02.82.11

10. ALL WASTE CONTAINERS, EQUIPMENT, ETC.

SHALL BE WET WIPED PRIOR TO LEAVING

REGULATED WORK AREA.

11. NIGHTS WORK IS TO BE PERFORMED DURING

OFF HOURS FROM 5:00 PM - 7:00 AM MONDAY

THROUGH FRIDAY AND WEEKEND WORK FRIDAY 6

PM THROUGH SUNDAY. WORK IS PROHIBITED ON

FEDERAL HOLIDAYS.

12. ASBESTOS RELATED MATERIALS ARE PRESENT

AND MAY NOT SHOWN ON DRAWINGS FOR CLARITY.

KNOWN ASBESTOS MATERIALS INCLUDE FIRE

DOORS, SOILS, DOOR AND WINDOW CAULKS,

WINDOWS GLAZING, FLOOR TILE GROUPS AND

ASSOCIATED UNDERLYING ASBESTOS MASTIC,

FOUNDATION WATERPROOFING, TRANSITE AT

WINDOW CONVECTORS, ASBESTOS DRYWALL

ADHESIVES WHERE APPLIED TO WALL BLOCKS,

GREEN MARBLE WALL PANELS, ACOUSTICAL LOBBY

PLASTER, BLACK OR WHITE DUCT SEAM SEALANTS

AND APPLICATIONS, SINK SOUND PROOFING,

VIBRATION ISOLATION DUCT JOINTS, ASBESTOS

PIPE INSULATION AND MUDDED FITTINGS, AND

GALBESTOS COATED DUCTWORK. PROTECT AS

NECESSARY.

13. AT INTERIOR REGULATED AREAS (NPE), WHERE

THE COMBINED FOOTPRINT OF WORK CHAMBER,

DECONTAMINATION CHAMBERS AND LOADOUT

DOES NOT FIT WITHIN THE ROOM, THE

DECON/LOADOUT CONFIGURATION MAY EXTEND

INTO 1/2 WIDTH OF THE HALLWAY AS REQUIRED TO

ALLOW PASSAGE IN CORRIDOR.

A2

A3

A4

L1

L2

VISUAL KEY

ASBESTOS PIPE INSULATION AND/OR MUDDED

FITTINGS

BLDG 1 FLOOR TWO ENVIRONMENTAL

r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-201

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

BLDG 1 FLOOR TWO

CONTAINMENT DETAILS

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

VISUAL KEY

NEGATIVE PRESSURE ENCLOSURE (NPE)

HEPA FILTERED NEGATIVE AIR MACHINES WITH SUGGESTED TUBING DIRECTION

3 STAGE WET DECONTAMINATION STATION (WITH SHOWER)

2 STAGE WASTE LOAD OUT CHAMBER

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS AND ON NIGHTS AND

WEEKENDS, REMOVE CONTAMINATED CEILING

TILES, APPLY TWO LAYERS OF COVERING LAG

CLOTH OVER DAMAGE/DEFECTS, 14

CONTAINMENTS, 8 DEFECTS WITHIN EACH

CONTAINMENT, 3,500 SF CEILING TILES

A1

A1

A1

A1

N

2nd FLOOR

3003 3004

3005A

3STAIR

3024A

3B

3026A

3034A 3035

3037A

3STAIR

3040A

3041A

30413042

3041C

3041B

3042A

3C

3054A

3054B

3STAIR

3072A

3STAIR

3085A

3094A

3094B

3000A

30983100

31063107

3110A

3111A

3111B

3111C

3E

3STAIR

3116A

3118 3119

3STAIR

A

3STAIR

3A

3D

3F

DN

UP

DN

UP

FE

FE

FE

FE

FE

FE

N

3RD FLOOR

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS AND ON NIGHTS AND

WEEKENDS, REMOVE CONTAMINATED CEILING

TILES, APPLY TWO LAYERS OF COVERING LAG

CLOTH OVER DAMAGE/DEFECTS, 5 CONTAINMENTS,

8 DEFECTS WITHIN EACH CONTAINMENT, 1,450 SF

CEILING TILES

BROWN/TAN ASBESTOS DRYWALL ADHESIVE

PRESENT ON METAL DRYWALL FURRING STRIPS,

DRYWALL, AND/OR CERAMIC WALL BLOCKS

UNDERLYING DRYWALL DECORATIVE FACE,

LOCATED THROUGHOUT CORRIDORS, PROTECT AS

NECESSARY.

DO NOT DISTURB, PROTECT AS NECESSARY. USE

NON INVASIVE SURFACE MOUNT WALL DATA JACK

SYSTEM WITH MASTIC OR SIMILAR.ASBESTOS

BLACK MASTIC PRESENT BEHIND GREEN OR

OTHERWISE PAINTED MARBLEIZED WALL PANELS,

USE EXISTING SLEEVES THROUGH COMMON

CORRIDOR WALLS AND WITHIN ROOMS.

DAMAGED ASBESTOS PIPE INSULATION PRESENT,

DO NOT PERFORM WORK IN THIS AREA (DO NOT

REMOVE CEILING SYSTEM TILES), PROTECT AS

NECESSARY.

DO NOT DISTURB BLOCK OR PLASTER CHASES

WITH ASBESTOS PIPE INSULATION, PROTECT LEAD

CONTAINING WALL BLOCKS AND/OR LEAD LINED

DRYWALL, PROTECT AS NECESSARY. USE NON

INVASIVE SURFACE MOUNT WALL DATA JACK

SYSTEM WITH MASTIC OR SIMILAR.

DENOTES REPRESENTATIVE LOCATIONS OF LEAD

CONTAINING CERAMIC WALL BLOCKS, OR LEAD

CONTAINING CERAMIC WALL TILES GENERALLY 4" X

4". WALL BLOCKS WHERE NOTED AS LEADED,

APPEAR TO BE OFF COLOR OR PATTERN AND ARE

THOUGHT TO REPRESENT AREAS "OF REPAIR" OR

HAVE BEEN PAINTED (LBP). CERAMIC WALL TILES

ARE GENERALLY PRESENT WHERE SINKS ARE

EXISTING AND ALL LOCATIONS ARE NOT SHOWN

FOR CLARITY PURPOSES. DO NOT DISTURB

CERAMIC WALL TILES AND LEADED CERAMIC WALL

BLOCKS WHERE SHOWN. PROTECT AS NECESSARY.

USE NON INVASIVE SURFACE MOUNT WALL DATA

JACK SYSTEM WITH MASTIC OR SIMILAR.

A1

A1

A2

A2

A1

A2

A2

A1

L1

A4

A1

A1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

A2

A4

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A3

A5

A5

A3

A5

VISUAL KEY

ASBESTOS PIPE INSULATION AND/OR MUDDED

FITTINGS

GENERAL COMMENTS

1. ALL ACM ABATEMENT OR ENCLOSURE WORK

SHALL BE PERFORMED BY PROPERLY

TRAINED/LICENSED ASBESTOS ABATEMENT

CONTRACTOR WITHIN A FULL CONTAINMENT

UNDER NEGATIVE PRESSURE (NPE).

2. ALL HVAC AIR INTAKES WITHIN NPE SHALL BE

SHUT DOWN AND ISOLATED WITH CRITICAL

BARRIERS DURING ACTIVE ACM REMOVAL OR

ENCLOSURE WORK. WORK TO BE SCHEDULED WITH

GENERAL CONTRACTOR AND OWNER TO

ACCOMMODATE CONSTRUCTION AND FACILITY

REQUIREMENTS.

3. WORKERS PERFORMING ACM REMOVAL OR

ENCLOSURE SHALL DON, AT MINIMUM, HALF FACE

AIR PURIFYING RESPIRATORS WITH P100 FILTERS,

DISPOSABLE DUST SUITS (WITH BOOT COVERS)

AND GLOVES DURING ACTIVE TASKS, WHICH SHALL

BE SUPPLEMENTED WITH USE OF POWERED AIR

PURIFYING RESPIRATORS.

4. ACM REMOVAL WORK AREAS SHALL BE

PREPARED IN ACCORDANCE WITH THE FOLLOWING:

A) ALL FLOORS, CEILINGS AND WALLS SHALL BE

ISOLATED USING 2-LAYERS OF 6-MIL POLY

SHEETING; B) OSHA ASBESTOS SIGNAGE AT

ENTRANCE TO REGULATED AREAS; C)SINGLE-POINT

OF ENTRY WITH 3-STAGE WET DECONTAMINATION

STATION TO ALLOW WORKERS TO REMOVE PPE,

WASH AND VACUUM THEMSELVES OFF PRIOR TO

EXITING THE REGULATED WORK AREA; D)

MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN

WG OR BETTER) USING HEPA FILTERED AIR

MACHINES WITH EXHAUST ROUTED TO OUTDOORS;

E) MINIMUM OF 4 AIR CHANGES PER HOUR; F)

CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS

TO CHANGE INTO STREET CLOTHES (OPAQUE POLY

REQUIRED AS NEEDED FOR PRIVACY); G)

RENEWABLE ADHESIVE MATS IMMEDIATELY

OUTSIDE OF REGULATED WORK AREA TO ENSURE

FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO

OTHER AREAS OF FACILITY.

5. ACM WORK TO BE PERFORMED USING THE

FOLLOWING CONTROLS: A) HEPA FILTERED

VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B)

ONLY MANUAL REMOVAL MEANS/TOOLS ARE

ALLOWED TO DISTURB ACM (MECHANICAL TOOLS

PROHIBITED FOR ACM REMOVAL).

6. REGULATED WORK AREA IS TO BE CLEANED BY

CONTRACTOR FOLLOWING COMPONENT REMOVAL

USING STANDARD HEPA VACUUM & WET WIPING

METHODS AND VISUALLY INSPECTED AND

CLEARANCE SAMPLED BY VA REPRESENTATIVE TO

VERIFY COMPLETION OF SCOPE.

7. VPIH IS TO BE RESPONSIBLE FOR PERIMETER AIR

MONITORING AND FINAL CLEARANCE AIR

SAMPLING/VISUAL INSPECTION REQUIREMENTS.

8. CONTRACTOR TO BE RESPONSIBLE FOR OSHA

EMPLOYEE EXPOSURE MONITORING

REQUIREMENTS.

9. ALL WASTE PRODUCED DURING REMEDIATION

PHASE SHALL BE COLLECTED, CONTAINERIZED,

LABELED, CHARACTERIZED AND DISPOSED IN

ACCORDANCE WITH SPECIFICATION 02.82.11

10. ALL WASTE CONTAINERS, EQUIPMENT, ETC.

SHALL BE WET WIPED PRIOR TO LEAVING

REGULATED WORK AREA.

11. NIGHTS WORK IS TO BE PERFORMED DURING

OFF HOURS FROM 5:00 PM - 7:00 AM MONDAY

THROUGH FRIDAY AND WEEKEND WORK FRIDAY 6

PM THROUGH SUNDAY. WORK IS PROHIBITED ON

FEDERAL HOLIDAYS.

12. ASBESTOS RELATED MATERIALS ARE PRESENT

AND MAY NOT SHOWN ON DRAWINGS FOR CLARITY.

KNOWN ASBESTOS MATERIALS INCLUDE FIRE

DOORS, SOILS, DOOR AND WINDOW CAULKS,

WINDOWS GLAZING, FLOOR TILE GROUPS AND

ASSOCIATED UNDERLYING ASBESTOS MASTIC,

FOUNDATION WATERPROOFING, TRANSITE AT

WINDOW CONVECTORS, ASBESTOS DRYWALL

ADHESIVES WHERE APPLIED TO WALL BLOCKS,

GREEN MARBLE WALL PANELS, ACOUSTICAL LOBBY

PLASTER, BLACK OR WHITE DUCT SEAM SEALANTS

AND APPLICATIONS, SINK SOUND PROOFING,

VIBRATION ISOLATION DUCT JOINTS, ASBESTOS

PIPE INSULATION AND MUDDED FITTINGS, AND

GALBESTOS COATED DUCTWORK. PROTECT AS

NECESSARY.

13. AT INTERIOR REGULATED AREAS (NPE), WHERE

THE COMBINED FOOTPRINT OF WORK CHAMBER,

DECONTAMINATION CHAMBERS AND LOADOUT

DOES NOT FIT WITHIN THE ROOM, THE

DECON/LOADOUT CONFIGURATION MAY EXTEND

INTO 1/2 WIDTH OF THE HALLWAY AS REQUIRED TO

ALLOW PASSAGE IN CORRIDOR.

A2

A3

A4

A5

L1

A5

A5

A5

A5

A5

A5

A5

A5

A5

L1

A5

A5

A5 t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-300

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

BLDG 1 FLOOR THREE

r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-301

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

BLDG 1 FLOOR THREE

CONTAINMENT DETAILS

N

3RD FLOOR

VISUAL KEY

NEGATIVE PRESSURE ENCLOSURE (NPE)

HEPA FILTERED NEGATIVE AIR MACHINES WITH SUGGESTED TUBING DIRECTION

3 STAGE WET DECONTAMINATION STATION (WITH SHOWER)

2 STAGE WASTE LOAD OUT CHAMBER

KEYED NOTES

DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,

AND/OR OPEN JOINTS. WITHIN NEGATIVE

PRESSURE CONTAINMENTS AND ON NIGHTS AND

WEEKENDS, REMOVE CONTAMINATED CEILING

TILES, APPLY TWO LAYERS OF COVERING LAG

CLOTH OVER DAMAGE/DEFECTS, 5 CONTAINMENTS,

8 DEFECTS WITHIN EACH CONTAINMENT, 1,450 SF

CEILING TILES

A1

A1

A1

A1

A1

A1

A1 r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t

1 2 � 4 � 6 � 8 �

Veterans

Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

REVISION: DATE:

ARCHITECT:

U.S. Department of Veteran Affairs

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

MO ARCH REG. NO. 2012034754, EXP. 12/31/2022

MO ENGR REG. NO. 2014031351, EXP. 12/31/2022

CIVIL ENGINEER

OLSSON

550 ST. LOUIS ST.

SPRINGFIELD, MO 65806

(417) 885-1736

STRUCTURAL ENGINEER

STAND STRUCTURAL ENGINEER

8234 ROBINSON ST.

OVERLAND PARK, KS 66204

(913) 214-9525

MECH / ELEC / PLUMB ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(405) 842-6100

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

F U

L L

Y

S

P R

I N

K L

E R

E D

ABATEMENT

RIVERFRONT SAFETY AND HEALTH

11140 S. TOWNE SQ., STE 100

SAINT LOUIS, MO 63123

(314) 917--148

TELECOM

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE

PRESCOTT, AZ 86301

(928) 774-0992

A

M

01-HA-400

CD

JR

RESUBMITTED 100% CONSTRUCTION DOCUMENTS

EHRM INFRASTRUCTURE UPGRADES

03/23/2021

657A4-20-700

John J. Pershing VA Medical Center

1500 N. Westwood Blvd.

Poplar Bluff, MO 63901

KEYED NOTES

DAMAGED ASBESTOS PIPE…