TP09 Final Drawings 07 657A4-20-700 Resubmitted SS 100 percent CD Drawings-Plumbing.pdf
PDF 1 MB Posted
- Attached to
- Y1DZ--657A4-20-700, EHRM INFRASTRUCTURE UPGRADES Federal contract opportunity
- Solicitation number
- 36C25521R0103
About this file
This solicitation is for construction services for infrastructure upgrades at the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. The contractor shall provide all labor, materials, equipment, supervision and expertise to complete upgrades to the fiber backbone, construct a new server room, renovate O&IT closets to include HVAC cooling and controls, patch panel upgrades, cabling upgrades to CAT6A, additional power and data drops, and power upgrades to closets and the telephone room. Work shall be performed in a manner to not disrupt medical center operations. The period of performance is estimated at 365 calendar days from notice to proceed. The principal NAICS code is 236220 for commercial and institutional building construction. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 15.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MA
MV
CO
EV
VE
AI
FOV
FOR
FOS
FP
LPG
NPW
NO
O
N
G
MPG
G
MPG
CA
CD
ACD
V
VBG
VBF
AV
AW
AW
ST
OST
GW
GW
S
W
ID
T
T
SCW
WS
140°
S
W
CAP
AV
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT
PUMP NO.3 IN BUILDING NO.26
EQUIPMENT ABBREVIATION (PUMP)
IS LOCATED.
ORAL EVACUATION
LABORATORY VACUUM
LABORATORY AIR
TEMPERED WATER RETURN
TEMPERED WATER SUPPLY
INDUSTRIAL AIR
LA
LV
OA
IA
TWR
TWS
FILTERED COLD WATERFCW
FUEL OIL DISCHARGEFOD
ANCHOR
CONNECTION - SIDE
ECCENTRIC REDUCER
CONNECTION - BOTTOM, 45° OR 90°
CONNECTION - TOP, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
RISE OR DROP IN PIPE
STRAINER
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES
PIPING ACCESSORIES
INVERTED BUCKET TRAP SET INCLUDING
FLOOR DRAIN (FD), SIZE & TYPE
ROOF DRAIN (RD), SIZE & TYPE
FLOOR SINK (FS), SIZE & TYPE
NATURAL GAS BELOW GRADE (G)
CONDENSATE DRAIN (CD)
INDIRECT DRAIN (ID)
NATURAL GAS (G)
NITROUS OXIDE (NO)
LIQUIFIED PETROLEUM GAS (LPG)
FIRE PROTECTION (FP)
WATER SERVICE (WS)
COMPRESSED AIR (CA)
NITROGEN (N)
MEDICAL AIR (MA)
OXYGEN (O)
DOMESTIC HOT WATER RECIRC.
SOIL PIPING - ABOVE FLOOR (S)
SOIL PIPING - BELOW FLOOR (S)
STORM DRAIN - ABOVE FLOOR (ST)
ACID WASTE - ABOVE FLOOR (AW)
ACID WASTE - BELOW FLOOR (AW)
DOMESTIC COLD WATER
DOMESTIC HOT WATER
140° DOMESTIC HOT WATER (140°)
WASTE PIPING - ABOVE FLOOR (W)
WASTE PIPING - BELOW FLOOR (W)
GREASE WASTE - ABOVE FLOOR (GW)
GREASE WASTE - BELOW FLOOR (GW)
SOFTENED COLD WATER (SCW)
ACID VENT (AV)
VENT PIPING (V)
HOSE BIBB (HB)
NONFREEZE WALL HYDRANT (NW)
WALL CLEANOUT (WCO)
FLOOR CLEANOUT (FCO)
EXTERIOR CLEANOUT (ECO)
THERMOSTATIC MIXING VALVE
BACKFLOW PREVENTER
OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)
NON POTABLE WATER (NPW)
FUEL OIL SUPPLY (FOS)
FUEL OIL RETURN (FOR)
FUEL OIL VENT (FOV)
AUXILIARY CONDENSATE DRAIN (ACD)
VENT BELOW GRADE (VBG)
VENT BELOW FLOOR (VBF)
CARBON DIOXIDE (CO)
MEDICAL VACUUM (MV)
EVACUATION (EV)
MEDICAL VACUUM EXHAUST (VE)
MEDICAL AIR INTAKE (AI)
TRAP PRIMER LINE (T)
WATER METER
MEDIUM PRESSURE NATURAL GAS (MPG)
MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)
ELBOW DOWN WITH SHUT-OFF VALVE (SOV)
TEE DOWN WITH SHUT-OFF VALVE (SOV)
TEE UP WITH SHUT-OFF VALVE (SOV)
RECIRCULATION PUMP
DIRECTION OF FLOW
EXISTING PIPING TO REMAIN
EXISTING PIPING TO BE REMOVED
FLANGE CONNECTION
CLEANOUT
ELBOW DOWN
ELBOW UP
TEE DOWN
ELBOW UP WITH SHUT-OFF VALVE (SOV)
TEE UP
UNION
THERMOMETER
PRESSURE GAUGE
PRESSURE REDUCING VALVE
REDUCER
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENT
PLUMBING KEYNOTE
PLUMBING EQUIPMENT DESIGNATION
MECHANICAL EQUIPMENT DESIGNATION TAG
OWNER FURNISHED, CONTRACTOR INSTALLED
EQUIPMENT DESIGNATION
NEW WORK TO EXISTING WORK CONNECTION POINT
DETAIL NUMBER
SHEET NUMBER
LIMIT OF DEMOLITION
TRAP PRIMER LINE - BELOW SLAB (T)
CO
DOUBLE EXTERIOR CLEANOUT (ECO)
CLEANOUTS
DRAINS AND TRAPS
EQUIPMENT
FITTINGS AND ACCESSORIES
SHEET NUMBER
SECTION NUMBER
MEDICAL GAS OUTLET (TYPE)
EXISTING TO REMAIN
A
A/E ARCHITECT / ENGINEER
AD AREA DRAIN/ACCESS DOOR
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASHRAE AMERICAN SOCIETY OF HEATING,REFRIGERATION, AIR
CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
B
BFP REDUCED PRESSURE BACKFLOW PREVENTER
BHP BREAK HORSEPOWER
BSP BLACK STEEL PIPE
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C
C CELSIUS
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CO CLEANOUT
CS CLINICAL SINK
CV CONTROL VALVE
D
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
E
EL ELEVATION
EMCS ENERGY MONOSERRAT AND CENTRAL SYSTEM
EPA ENVIROMENTAL PROTECTION AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EWS/SH EYE WASH/DRENCH SHOWER
EX EXISTING
F
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FM FLOW METER
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
G
GAL GALLON
GCO GRADE CLEANOUTS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
H
H&CW HOT AND COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST HOT WATER STORAGE TANK (DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
I
ID INSIDE DIAMETER
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
K
KW KILOWATT
KWH KILOWATT-HOUR
L
L/S LITER PER SECOND
LA LABORATORY AIR
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LV LABORATORY VACUUM
LW LOW WATER
M
M METER
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH 1000 BTUH
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MOU MEMORANDUM OF UNDERSTANDING
MSB MOP SERVICE BASIN
MV MEDICAL VACUUM
N
N2 NITROGEN
N20 NITROUS OXIDE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM. NOMINAL
NPW NON POTABLE WATER
NTS NOT TO SCALE
O
O OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
P
PA PASCAL
PD PRESSURE DROP OR DIFFERENCE
PDI PLUMBING AND DRAINAGE INSTITUTE
PG PRESSURE GAGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH ATMOSPHERE
PSIG POUNDS PER SQUARE INCH GAUGE
PTRV PRESSURE TEMPERATURE RELIEF VALVE
PW POTABLE WATER
R
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RO REVERSE OSMOSIS WATER
RWL RAIN WATER LEADER
S
SAN SANITARY SEWER
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
SCFM STANDARD CUBIC FOOT/MINUTE
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SMH SANITARY MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQFT/SF SQUARE FEET
SS STAINLESS STEEL
ST STORAGE TANK
SW STORM WATER
T
TCV TEMPERATURE CONTROL VALVE
TD TEMPERATURE DIFFERENCE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
V
V VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAGE
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
Y
YCO YARD CLEANOUT
YH YARD HYDRANT
26-P 3
PIPING SYMBOLS
ANNOTATION
XX-1
xx
PL-100
PL-100
GENERAL PLUMBING SYMBOLS
DENTAL
MEDICAL GASES
STORM
FUEL
EXISTING PIPING
WATER
WASTE
VALVE SYMBOLS
ETR
ABBREVIATIONS
ETR EXISTING TO REMAIN
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
FFA FROM FLOOR ABOVE
FFB FROM FLOOR BELOW
THIS LEGEND DEFINING TYPICAL ABBREVIATIONS AND SYMBOLS IS INTENDED TO BE AN OVERALL LEGEND FOR ALL PROJECTS. PLEASE UNDERSTAND THAT NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR EVERY PROJECT. MANY OF THE SYMBOLS WILL BE UTILIZED IN DETAILS AND DIAGRAMS VICE PLAN SHEETS.
EXISTING TO DEMOLISHETD
ST STORM DRAIN - BELOW FLOOR (ST)
PLUMBING GENERAL NOTES:
A. SLOPE SOIL AND WASTE PIPE 4" AND LARGER AT 1/8" PER FT. MINIMUM, SIZE LESS
THAN 4" SLOPE 1/4" PER FT. MINIMUM, UNLESS NOTED OTHERWISE.
B. ALL PIPING SHALL BE COORDINATED WITH CIVIL UTILITY PIPING, FIRE PROTECTION,
DUCTWORK, MECHANICAL PIPING, LIGHTING, STRUCTURAL AND ARCHITECTURAL
SYSTEMS.
C. PIPE CLEANOUTS SHALL BE LINE SIZE (6" MAX.). LOCATE 100' APART MAXIMUM FOR
SIZES UP THROUGH 6".
D. PLUMBING VENTS THROUGH ROOF (VTR) SHALL BE 3" MINIMUM. SMALLER VTR'S
INDICATED SHALL INCREASE TO 3" PIPE, 12" BELOW ROOF.
E. ACCESS PANELS SHALL BE PROVIDED FOR ALL WATER HAMMER ARRESTORS
LOCATED IN WALLS TO ACCESS EQUIPMENT. PANEL SHALL BE AS LARGE AS
PRACTICAL FOR THE FUNCTION THEY ARE INTENDED.
F. DO NOT SCALE DRAWINGS, SEE ARCHITECTURAL FLOOR PLAN FOR DIMENSIONS.
G. ALL PLUMBING WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL PLUMBING
CODE.
H. PIPE ROUTING IS SCHEMATIC AS SHOWN AND IS NOT INTENDED TO INDICATE EXACT
ROUTING. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSET AND FITTINGS
REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES.
I. CONCEAL PIPING ABOVE CEILING AND WITHIN WALLS OR CHASES, EXCEPT IN
MECHANICAL SPACES OR WHEN OTHERWISE NOTED.
J. SEE ACRCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING
HEIGHTS.
K. PROVIDE TRAP PROTECTION FOR ALL FLOOR DRAINS.
L. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES,
DEVICES, APPLIANCES AND APPARATUS.
M. CORRDINATE PIPING WITH ELECTRICAL EQUIPMENT PRIOR TO INSTALLATION. ROUTE
PIPING TO AVOID ELECTRICAL EQUIPMENT AND CLEARANCE AREAS.
N. ANY DEVIATIONS IN ELECTRICAL REQUIREMENTS FROM THE BASIS OF DESIGN FOR
THE PLUMBING EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE PLUMBING
CONTRACTOR TO ENSURE COORDINATION WITH THE ELECTRICAL CONTRACTOR FOR
PROPER SIZE ELECTRICAL MATERIAL AND EQUIPMENT AT NO ADDITIONAL COST.
O. PROVIDE SHOCK ARRESTORS PER PDI-WH-201.
P. THE PLUMBING CONTRACTOR SHALL NOT USE SADDLE TAPS/VALVES FOR ANY NEW
PLUMBING CONSTRUCTION. COORDINATE WITH THE VA COR FOR PREFERRED
CONNECTION METHODS.
Q. THE PLUMBING CONTRACTOR SHALL OPTIMIZE THE PHASING OF ALL PLUMBING
DEMOLITION AND NEW PLUMBING CONSTRUCTION TO AVOID IMPACTING THE DAILY
VA FACILITY OPERATIONS. COORDINATE WITH THE VA COR FOR PHASING AND
OPERATION SCHEDULES.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
REVISION: DATE:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2022
MO ENGR REG. NO. 2014031351, EXP. 12/31/2022
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEER
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-9525
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
F U
L L
Y S
P R
IN
K
L E
R E
D
ABATEMENT
RIVERFRONT SAFETY AND HEALTH
11140 S. TOWNE SQ., STE 100
SAINT LOUIS, MO 63123
(314) 917-0148
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
/2
/2
:2
:3
A
M
P-000
PLUMBING LEGEND AND
ABBREVIATIONS
SCP
JRM
RESUBMITTED 100% CONSTRUCTION DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES
03/23/2021
657A4-20-700
John J. Pershing VA Medical Center 1500 N. Westwood Blvd.
Poplar Bluff, MO 63901
DN
DN
OI&T
OI&T
ELECTRICAL CLOSET
01D
OI&T SERVER ROOM
52B
1-P-100
1-P-100
3 CORRIDOR
GA
OI&T SERVER ROOM
52B
3/4" CW
3/4" CW
P-801
1 32
A
E
B
D
C
1/4" CW
1/2" CW 1/4" CW
CRU-1 CRU-2
CRU-3
1/4" CW
5 5
D1
D2 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
REVISION: DATE:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2022
MO ENGR REG. NO. 2014031351, EXP. 12/31/2022
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEER
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-9525
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
F U
L L
Y S
P R
IN
K
L E
R E
D
ABATEMENT
RIVERFRONT SAFETY AND HEALTH
11140 S. TOWNE SQ., STE 100
SAINT LOUIS, MO 63123
(314) 917-0148
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
/2
/2
:2
:3
A
M
1-P-100
BLDG 1 - PLUMBING GROUND FLOOR
PLAN
SCP
JRM
RESUBMITTED 100% CONSTRUCTION DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES
03/23/2021
657A4-20-700
John J. Pershing VA Medical Center 1500 N. Westwood Blvd.
Poplar Bluff, MO 63901
N
1/16" = 1'-0"
BLDG 1 - PLUMBING GROUND FLOOR PLAN1
PLUMBING DEMO PLAN NOTES
D1 REMOVE HOSE BIBB AND ASSOCIATED CW LINE BACK TO NEAREST BRANCH AND
PREPARE FOR NEW 3/4" CW CONNECTION.
D2 REMOVE FLOOR DRAIN AND ASSOCIATED ACCESSORIES. CAP ASSOCIATED SANITARY
WASTE LINE BELOW FLOOR.
PLUMBING PLAN NOTES
1 TAP NEW 3/4" CW LINE FROM NEAREST EXISTING BRANCH.
2 ROUTE DOMESTIC WATER PIPING AS SHOWN ON THIS PLAN TO WALL HYDRANT. HOLD
PIPING TIGHT TO WALL AND AWAY FROM ANY ELECTRICAL EQUIPMENT. ROUTE PIPING
AS HIGH AS POSSIBLE. OFFSET AS NECESSARY TO COORDINATE EXACT PIPE
ELEVATION WITH MECHANICAL, ELECTRICAL, TELECOMMUNICATION, AND
STRUCTURAL TRADES.
3 TURN CW LINE UP AND PROVIDE SHUT-OFF VALVE ON THE VERTICAL RUN AT AN
ACCESSIBLE HEIGHT.
4 ROUTE 1/4" CW DOWN TO CRU HUMIDIFIER.
5 ROUTE DOMESTIC WATER PIPING AS SHOWN ON THIS PLAN TO CRU HUMIDIFIER. HOLD
PIPING TIGHT TO WALL AND AWAY FROM ANY ELECTRICAL EQUIPMENT. ROUTE PIPING
AS HIGH AS POSSIBLE. OFFSET AS NECESSARY TO COORDINATE EXACT PIPE
ELEVATION WITH MECHANICAL, ELECTRICAL, TELECOMMUNICATION, AND
STRUCTURAL TRADES.
N
1/8" = 1'-0"
SERVER ROOM ENLARGED PLAN2
N
1/4" = 1'-0"
GROUND FLOOR ENLARGED DEMOLITION PLAN3
HOT PIPECOLD PIPE
REFER TO SPECIFICATIONS FOR INSULATION TYPES,
INSULATION THICKNESSES, HANGER TYPES, HANGER ROD
CONNECTIONS TO SRUCTURE AND HANGER SPACING.
CUT INSULATION TO FIT
AROUND HANGER. SEAL
EXPOSED INSULATION
ENDS WITH JOINT
SEALANT.
PROVIDE A SECTION OF HIGH
DENSITY INSULATION OR
STYROFOAM BILLETS AT EACH
HANGER OF COLD INSULATED
PIPE.
THREADED STEEL ROD
WITH NUT AND WASHER
BOTH SIDES (TYP.).
CLEVIS HANGER, SHOWN FOR
CLARITY. SIZE HANGER FOR
COLD PIPE OUTSIDE DIAMETER
PLUS INSULATION THICKNESS.
DO NOT PENETRATE INSULATION
WITHE HANGER.
CLEVIS HANGER, SHOWN
FOR CLARITY. SIZE
HANGER FOR HOT PIPE
OUTSIDE DIAMETER.
SECURE PIPE HANGER
TO STRUCTURE (TYP.)
PROVIDE SHORT INSULATION
SHIELD FOR LAPPING
INSULATION JACKET OVER HIGH
DENSITY INSULATION OR
STYROFOAM BILLETS. MAINTAIN
VAPOR BARRIER.
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITONS. REFER TO
SPECIFICATIONS FOR MORE INFORMATION. PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON
THE SAME SUPPORT CHANNEL. COORDINATE SUPPORT CHANNEL LENGTH WITH PIPING AND CONDUIT
TO BE SUPPORTED. SUPPORT CHANNEL SPACING SHALL BE DETERMINED BY SMALLEST PIPE TO BE
SUPPORTED. CHANNEL SUPPORT MAY BE USED AS A WALL BRACKET, ATTACH TO WALL WITH ANCHOR
BOLTS PER SPECIFICATIONS. FOR HORIZONTAL INSULATED PIPING, ATTACH CLAMPS AS INDICATED
ABOVE, FOR VERTICAL INSULATED PIPING, ATTACH CLAMPS TO THE PIPE AND SEAL INSULATION AT BOTH
CLAMP ENDS.
SUPPORT WASHERS AND
LOCKNUTS (TYP.).
UNINSULATED STEEL OR
PLASTIC PIPE.
PROVIDE PLASTIC GALVANIC
ISOLATOR FOR COPPER PIPE
(TYP.)
UNINSULATED COPPER PIPE.
COLD INSULATED PIPE.
PIPE INSULATION (TYP.)
HOT INSULATED PIPE.
PROVIDE 1-5/8"x1-5/8" 14 GA.
CHANNEL SUPPORT.
CUT INSULATION TO FIT AROUND
TRAPEZE HANGER. SEAL BOTH
ENDS OF EXPOSED INSULATION
WITH JOINT SEALANT.
PROVIDE METAL 360° INSULATION SHIELD
AND HIGH DENSITY INSULATION OR
PRE-ENGINEERED THERMAL
HANGER-SHIELD INSERT OF CALCIUM
SILICATE INSULATION. FOR PIPES 4" AND
SMALLER, PRE-ENGINEERED THERMAL
HANGER-SHIELD INSERT OF FLEXIBLE
UNICELLULAR INSULATION MAY BE
PROVIDED.
SIZE AND QUANTITY OF HANGER
RODS PER MANUFACTURER'S
RECOMMENDATIONS.
PROVIDE TWO-PIECE PIPE
CLAMP (TYP.).
OVER 20'
UP TO 20'
155 - 330
NOTE:
PROVIDE ACCESS WHERE DEVICES ARE CONCEALED
WITHIN PARTITIONS OR ABOVE CEILINGS. SEE
SPECIFICATIONS 22 11 00 - 2.10
NEAREST DOMESTIC
WATER SUPPLY RISER
WATER HAMMER
ARRESTER
DOMESTIC WATER
SUPPLY PIPING TO
FIXTURES
NEAREST DOMESTIC
WATER SUPPLY RISER
WATER HAMMER
ARRESTER
DOMESTIC WATER
SUPPLY PIPING TO
FIXTURES
F
114 - 154E
61 - 113D
33 - 60C
12 - 32B
1 - 11A
FIXTURE UNIT RATINGMARK
WATER HAMMER ARRESTER SCHEDULE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
REVISION: DATE:
ARCHITECT:
U.S. Department of Veteran Affairs
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
MO ARCH REG. NO. 2012034754, EXP. 12/31/2022
MO ENGR REG. NO. 2014031351, EXP. 12/31/2022
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEER
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-9525
MECH / ELEC / PLUMB ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
F U
L L
Y S
P R
IN
K
L E
R E
D
ABATEMENT
RIVERFRONT SAFETY AND HEALTH
11140 S. TOWNE SQ., STE 100
SAINT LOUIS, MO 63123
(314) 917-0148
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
/2
/2
:2
:3
A
M
1-P-501
PLUMBING DETAILS AND SCHEDULES
SCP
JRM
RESUBMITTED 100% CONSTRUCTION DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES
03/23/2021
657A4-20-700
John J. Pershing VA Medical Center 1500 N. Westwood Blvd.
Poplar Bluff, MO 63901
NTS
PIPE HANGER DETAIL2 NTS
TRAPEZE PIPE HANGER1NTS
WATER HAMMER ARRESTOR DETAIL3
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION
WASTE PIPE
(IN)
VENT PIPE
(IN)
COLD WATER
(IN)
HOT WATER
(IN)
WASTE
FIXTURE
UNITS
WATER
FIXTURE
UNITS
WRIST
BLADE
HANDLES
ELECTRIC
SENSOR
POWER
REMARKS
HP MCA V/PH
P-801 WALL HYDRANT - - 0.75 - - 5 - - - - - Wall Hydrant: Cast bronze non-freeze hydrant with detachable T-handle and ASSE 1011 vacuum breaker.
WHA WATER HAMMER ARRESTOR - - VARIES VARIES - - - - - - -
Water Hammer Arrester: Precision Plumbing Products, ASSE 1010 OR PDI WH-201 Standards, hard drawn copper body and wrought copper fittings, piston type with lubricated EPDM O-Ring Seals, provide PDI sizes A-F as shown on plans.
| 73_P-000 - PLUMBING LEGEND AND ABBREVIATIONS |
| 74_1-P-100 - BLDG 1 - PLUMBING GROUND FLOOR PLAN |
| 75_1-P-501 - PLUMBING DETAILS AND SCHEDULES |
File details come from the government source that posted it. Updated .