TGI_3819P31002A01_c0v0_redact.pdf

PDF 860 KB Posted

Attached to
USS BLUE RIDGE 5C1 DSRA MODERNIZATION BUNDLE 3 (YOKOSUKA, JAPAN)
Solicitation number
N6264925RA041
Issued by

About this file

This document is a Task Group Instruction (TGI) for electrical work on Emergency Diesel Generator No. 2 for the USS Blue Ridge (LCC-19), part of an Extended Service Life Program Ship Service/Emergency Diesel Generator Generator-set Upgrade. The work involves comprehensive electrical modifications, removals, and installations across multiple ship compartments, including the Emergency Generator Room, Fan Rooms, Damage Control Central, various switchboard rooms, and other technical spaces.

The task is scheduled to start on 1/12/2026 and complete by 8/5/2027, with work encompassing upgrades to power systems, lighting systems, controllers, and various alarm and communication systems. Special requirements include working across fire zone boundaries, requiring non-flammable closures, and maintaining a Cleanliness Level III for piping systems and equipment. The instruction includes detailed material lists specifying specific steel components, electrical parts, and installation materials, with multiple references to technical drawings and specifications for precise implementation of the generator set upgrade.

View the file

Other files

File Type Posted
TGI_3819P31003A06_c0v0_redact.pdf PDF
TGI_3819P31003A05_c0v0_redact.pdf PDF
TGI_3819P31003A03_c0v0_redact.pdf PDF
TGI_3819P31003A02_c0v0.pdf PDF
TGI_3819P31002A04_c3v3.pdf PDF
TGI_3819P31001A01_c3v4.pdf PDF
TGI_3819P31003A01_c0v0_redact.pdf PDF
TGI_3819P31002A05_c2v0.pdf PDF
TGI_3819P31002A03_c3v2_redact.pdf PDF
TGI_3819P31002A02_c1v1_redact.pdf PDF
TGI_3819P31001A06_c2v1.pdf PDF
TGI_3819P31001A04_c2v2.pdf PDF
TGI_3819P31001A03_c0v0_redact.pdf PDF
Attachment II Price Proposal Form N6264925RA041_CLIN 0002 and CLIN 0004.xlsx XLSX spreadsheet
N6264925RA041-0010.pdf PDF
TGI_3819P31002A05_c2v0.pdf PDF
N6264925RA041-00006.pdf PDF
N6264925RA041-0003.pdf PDF
N6264925RA041-0002.pdf PDF
TGI_3819P31003A03_c0v0_redact.pdf PDF
TGI_3819P31002A04_c0v2_redact.pdf PDF
TGI_3819P31001A04_c2v2.pdf PDF
TGI_3819P31003T09_c0v0_redact.pdf PDF
TGI_3819P31003T06_c0v0_redact.pdf PDF
TGI_3819P31002T12_c0v0_redact.pdf PDF
TGI_3819P31002T09_c0v0_redact.pdf PDF
TGI_3819P31002T08_c0v0_redact.pdf PDF
TGI_3819P31002T06_c0v0_redact.pdf PDF
TGI_3819P31002T05_c0v0_redact.pdf PDF
TGI_3819P31002T01_c0v0_redact.pdf PDF
TGI_3819P31001T06_c0v0_redacted.pdf PDF
Attachment II Price Proposal Form N6264925RA041.xlsx XLSX spreadsheet
2.01 N6264925RA041.pdf PDF
TGI_3819P31003A05_c0v0_redact.pdf PDF
TGI_3819P31003A01_c0v0_redact.pdf PDF
TGI_3819P31001A03_c0v0_redact.pdf PDF
TGI_3819P31003T10_c0v0_redact.pdf PDF
TGI_3819P31003T05_c0v0_redact.pdf PDF
TGI_3819P31002T02_c0v0_redact.pdf PDF
TGI_3819P31001T09_c0v0_redacted.pdf PDF
TGI_3819P31001T05_c0v0_redacted.pdf PDF
Attachment V Contract Data Sheet.pdf PDF
TGI_3819P31002A06_c0v0_redact.pdf PDF
TGI_3819P31002A05_c1v0_redact.pdf PDF
TGI_3819P31002A03_c3v2_redact.pdf PDF
TGI_3819P31001A05_c0v0_redact.pdf PDF
TGI_3819P31001A02_c2v1_redact.pdf PDF
TGI_3819P31001A01_c0v3_redact.pdf PDF
TGI_3819P31003T04_c0v0_redact.pdf PDF
TGI_3819P31002T04_c0v0_redact.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOUO

FOUO: Public availability to be determined under 5 USC 552

TASK GROUP INSTRUCTION

AIM REV 20.11.4.0 (OCTOBER 2020)

TGI COMPONENT NAME: TYPE: PHASE: REPEAT: CHANGE:

NO.: SA 79243K ELEC EDG#2 AY A 0 0

SHIP/HULL NO.: SHIP/HULL NAME: SYSTEM: PROJ/WO NO: CASREP CAT:

LCC-19 USS BLUE RIDGE 19P

CU PHASE TITLE:

*(RE) F/O – S/A 79243K, ACCOMPLISH ELEC WORK FOR EDG#2, ESLP SS/EDG GENSET UPGRD

PREPARING ACTIVITY:

PREPARED BY: CODE PHONE DATE

KAZUKI UCHIMURA 233 080-9350-1432 15-FEB-2025

APPROVED BY: CODE PHONE DATE

MASAHIRO HOSONO 233 080-9350-1455 15-FEB-2025

CONCURRED BY: CODE PHONE DATE

CONCURRED BY: CODE PHONE DATE

CONCURRED BY: CODE PHONE DATE

CONCURRED BY: CODE PHONE DATE

REASON FOR WORK/NEED FOR CHANGE:

CHANGE INSTRUCTIONS:

SPECIAL REQUIREMENTS:

This work affects a fire zone boundary. Fabrication and/or staging of a non-flammable closure is required.

CLEANLINESS LEVEL FOR PIPING SYSTEM/EQUIPMENT LEVEL III.

WORK CERTIFICATION SIGNATURES

COMPLETION OF WORK REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:

ACCEPTANCE OF COMPLETED WORK

PHYSICAL INSPECTION PHYSICAL INSPECTION COMPLETED: BADGE NO.: SHOP/CODE: PHONE: DATE:

REQUIRED:☐YES ☒NO

RECORDS REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:

TGI NO.: SA 79243K ELEC EDG#2 AY A 0

FOUO

SHIP: LCC-19 CHG/VER: 0/0

LIST OF EFFECTIVE PAGES

SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO.

1-8 J1-4 M1-4 Engrg Inst (1- 2)

1. SCOPE/PURPOSE

1.1 Title: S/A 79243K, Electrical Work for Emergency Diesel Generator No. 2, Extended Service Life Program Ship Service/Emergency Diesel Generator Generator-set Upgrade; accomplish

1.2 Location of Work:

1.2.1 Emergency Generator Room No. 2 (7-109-1-E)

1.2.2 Fan Room (2-109-3-Q)

1.2.3 Passage (3-109-5-L)

1.2.4 Female Officers Head (3-109-7-L)

1.2.5 After Deck Gear Locker (3-109-11-Q)

1.2.6 State Room (3-111-1-L)

Remarks: Compartment name is changed to Fan Room (3-111-1-Q) by this S/A.

1.2.7 State Room (3-113-3-L)

1.2.8 X1 Store Room (3-120-1-A)

Remarks Compartment name is changed to Fan Room (3-120-1-Q) by this S/A.

1.2.9 Damage Control Central (4-81-1-Q)

1.2.10 Snap II Computer Room (4-103-2-Q)

1.2.11 Load Center Switchboard Room No. 6 (4-107-3-Q)

1.2.12 Passage (4-109-01-L)

1.2.13 Air Conditioning and Refrigeration Shop (4-109-3-Q)

1.2.14 Interior Communication and Gyro Room No. 2 (5-86-0-C)

1.2.15 Trunk (5-86-2-T)

1.2.16 Crew Living Space (5-109-0-L)

1.2.17 Trunk (5-109-1-T)

1.2.18 Physical Fitness Room (5-121-2-L)

1.2.19 Engine Room Enclosed Operating Station (6-86-0-E)

FOUO

SHIP: LCC-19 CHG/VER: 0/0

1.2.20 Self Service Storeroom (6-86-1-A)

1.2.21 Crew Living Space (6-98-0-L)

1.2.22 Emergency Switchgear Room No. 2 (6-109-1-E)

1.2.23 Trunk (6-117-0-T)

1.2.24 Deck Department Cleaning Gear Storeroom (6-118-1-A)

Remarks: Compartment name is changed to 400 Hz Equipment Room (6-118-1-Q) by this S/A.

1.2.25 Pump Room No. 2 and Air Conditioning and Machinery Room No. 2 (7-109-2-E)

1.2.26 Fire Room (8-76-0-E)

1.2.27 Engine Room (8-86-0-E)

1.2.28 Fresh Water Ballast (9-86-5-W)

1.2.29 Shaft Alley (9-98-0-Q)

1.2.30 JP5 (9-109-1-J)

1.2.31 JP5 (9-109-4-J)

1.2.32 Distillate Fuel or Ballast (9-121-1-F)

1.2.33 Cross Flooding Duct, Ninth Deck Frame 111

1.2.34 Underwater Hull Weather, Frames between 95 and 112, Starboard

1.3 Identification:

1.3.1 Quantity (One EA), Power System

Remarks: See 2.3 through 2.12, 2.21, 2.22, 2.24 and 2.25 for details.

1.3.1.1 Quantity (One EA), Controller for Emergency Diesel Generator (EDG) No.2 Seawater Pump Motor Remarks: See 2.7 for guidance.

1.3.1.2 Quantity (One EA), Controller for Ventilation Fan Supply System 3-111-1 Remarks: See 2.11 for guidance.

1.3.1.3 Quantity (One EA), Controller for Ventilation Fan Exhaust System 3-120-3 Remarks: See 2.11 for guidance.

1.3.1.4 Quantity (One EA), Controller for Fan Coil Assembly 6-118-1 Remarks: See 2.11 for guidance.

1.3.1.5 Quantity (One EA), Controller for Fan Coil Assembly 6-118-3 Remarks: See 2.11 for guidance.

1.3.2 Quantity (One EA), Lighting System

Remarks: See 2.13, 2.14, 2.21 and 2.22 for details.

1.3.3 Quantity (One EA), Halon Release Alarm System (2FR) for EDG No.2 Remarks: See 2.17, 2.18, 2.21 and 2.22 for details.

FOUO

SHIP: LCC-19 CHG/VER: 0/0

1.3.4 Quantity (One EA), APC Release and Low Press Alarm System (3FR) for EDG No.2 Remarks: See 2.18 and 2.22 for details.

1.3.5 Quantity (One EA), High Freon Alarm System (5AV) for EDG No.2 Remarks: See 2.18 and 2.22 for details.

1.3.6 Quantity (One EA), Special Frequency System (SF) for EDG No.2 Remarks: See 2.18 and 2.22 for details.

1.3.7 Quantity (One EA), Tank Level Indicator System (6TK) for EDG No.2 Remarks: See 2.18 and 2.22 for details.

1.3.8 Quantity (One EA), Tank Level Indicator System (7TK) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.9 Quantity (One EA), Television Closed Circuit System (2TV) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.10 Quantity (One EA), Surveillance Camera System (6TV) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.11 Quantity (One EA), Training and Entertainment Television System (14TV) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.12 Quantity (One EA), Dial Telephone System (J) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.13 Quantity (One EA), Sound Powered Telephone System (JAZ) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.14 Quantity (One EA), Sound Powered Telephone System (5JV) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.15 Quantity (One EA), Combustion Control System (BC) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.16 Quantity (One EA), Eyewash Flow System (AE) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.17 Quantity (One EA), Alarm Safety and Warning System (5EK) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.3.18 Quantity (One EA), General Announcing System (1MC) for EDG No.2 Remarks: See 2.17, 2.21 and 2.22 for details.

1.3.19 Quantity (One EA), Propulsion Plant Announcing System (2MC) for EDG No.2 Remarks: See 2.17 and 2.22 for details.

1.4 Security Classification: None.

1.5 Initial Condition:

1.5.1 Dry Dock Work

1.5.2 Potential Asbestos Hazard

FOUO

SHIP: LCC-19 CHG/VER: 0/0

1.5.3 Potential Lead Hazard

1.5.4 Potential PCB Hazard

1.6 Contractor work start date: 1/12/2026

1.7 Contractor work completion date: 8/5/2027

2. REFERENCES:

REF.

NO.

DOCUMENT

/DRAWING

NUMBER

DOCUMENT/DRAWING TITLE REV CHG

NO.

COPY

REQ’D

(Y/N)

SOURCE

DOC

(Y/N)

PARA SEC PG CHP

1 NSI FY25 Standard Items - ORG N 2 LI FY25 Local Standard Items - ORG N

3 DWG 301-

8621262

POWER SYSTEM 2000KW

EMERGENCY DIESEL

GENERATOR 2 UPGRADE

REMOVAL

B Y AL

L

4 DWG 301-

8621263

POWER SYSTEM 2000KW

EMERGENCY DIESEL

GENERATOR 2 UPGRADE

INSTALLATION

B Y AL

L

5 DWG 301-

8622091

EDG NO.2 PMP FUSE PANEL

POWER MODIFICATION

A Y AL

L

6 DWG 301-

8974218

LOAD CENTER MODIFICATIONS

INCIDENTAL TO EDG 2

UPGRADE

- Y AL

L

7 DWG 302-

8621268

POWER SYSTEM

MODIFICATIONS INCIDENTAL TO

EMERGENCY DIESEL

GENERATOR 2 UPGRADE

A Y AL

L

8 DWG 302-

8622228

POWER SYSTEM REMOVAL

EMERGENCY DIESEL

GENERATOR 2 UPGRADE

A Y AL

L

9 DWG 302-

8622229

POWER SYSTEM INSTALL

EMERGENCY DIESEL

GENERATOR 2 UPGRADE

A Y AL

L

10 DWG 302-

8622230

POWER SYSTEM REMOVAL EDG

2 UPGRADE HVAC

A Y AL

L

11 DWG 302-

8622231

POWER SYSTEM INSTALLATION

EDG 2 UPGRADE HVAC

B Y AL

L

12 DWG 302-

8974914

CABLEWAY MODIFICATIONS

INCIDENTAL TO EMERGENCY

DIESEL GENERATOR 2

- Y AL

L

13 DWG 303-

8622309

LIGHTING SYSTEM REMOVALS

EMERGENCY DIESEL

GENERATOR NO.2

A Y AL

L

14 DWG 303-

8622310

LIGHTING SYSTEM

INSTALLATION EMERGENCY

DIESEL GENERATOR NO. 2

A Y AL

L

15 DWG 345-

8574538

GENSET UPGRADE EQUIPMENT

ARRANGEMENT EDG RM 2 &

EMER SWITCHGEAR RM 2

B Y AL

L

16 DWG 345-

8622232

ARRANGEMANT MODIFICATIONS

400HZ EQUIPMENT ROOM

A Y AL

L

17 DWG 401-

8621382

MISC IC MODS INCDT TO SHIP

SERVICE EDG 2 REPLACMENT

A Y AL

L

18 DWG 401-

8623071

SCD 9243 MISC Damper Alarm Mods Incid to SCD 9243

A Y AL

L

19 DWG 245-

8783647

GENSET NODE MONITOR

EQUIPMENT ARRANGEMENT

ENGINE AND FIRE ROOM

- Y AL

L

FOUO

SHIP: LCC-19 CHG/VER: 0/0

REF.

NO.

DOCUMENT

/DRAWING

NUMBER

DOCUMENT/DRAWING TITLE REV CHG

NO.

COPY

REQ’D

(Y/N)

SOURCE

DOC

(Y/N)

PARA SEC PG CHP

20 LAR SRFY-

0276-24

DISCREPANCY IN DWG S/A 9243 - Y AL

L

21 LAR SRFY-

0034-25

DISCREPANCY IN DWGS OF SCD

9243 FOR EDG NO.2

- Y AL

L

22 PDD

302/303-

ELM-250189

SUPPL INFO FOR SCD 9243 FOR

EDG NO. 2

- Y AL

L

23 PDD 300-

ELM-230313

SRF-JRMC STD ELM

INSTALLATION OF STEEL &

CRES STUFFING TUBE

A Y AL

L

24 LAR SRFY-

0040–25

CHANGE THE LOCATION OF

POWER PANEL (6-118-1)

- Y AL

L

25 PDD 103-

ELM-250166

Patch for Removed Hull Penetration Incid to SCD 9243

- Y AL

L

26 DWG 604-

2491639

Metal Joiner BHD 3rd DK FR 76-

F Y AL

L

27 DWG 114-

2491159

AGC19 TRANSV BHD FR 121 &

J Y AL

L

28 DWG 604-

2491435

NON STRUCT BHD 3RD DK FR

98-AFT

G Y 23

29 DWG 114-

2491158

TRANSV BHD FR 98 &109 K Y AL

L

30 DWG 104-

8578042

Structural Modifications EDG No. 2 (7-109-1-E) SS/EDG Upgrade

A Y AL

L

31 DWG 104-

2491048

5th Deck PLTG FR51-1/2 - FR102- 1/4

M Y AL

L

32 MIL MIL-

STD-2003

Electric Plant Installation Standard Methods for Surface Ships and Submarines

B N

33 TM S9AA0-

AB-GOS-

010/GSO

General Specifications for Overhaul of Surface Ships (GSO)

11 N

3. APPENDICES:

3.1. Appendix “J” TGI Job Summary Information Sheet

3.2. Appendix "M" TGI Material List

3.3. Appendix “D” Deficiency Form

4. GENERAL REQUIREMENTS:

4.1 Not Applicable.

5. PROCEDURE:

5.1 Accomplish electrical removals, modifications and installations of the system listed in 1.3.1 through 1.3.19 in accordance with 2.3 through 2.25 and Enclosure-01, using 2.26 through 2.31 for guidance.

5.1.1 Electrical installations must be in accordance with 2.32.

5.1.2 Accomplish the requirements of 009-12 of 2.1, including Table 2, Column(s) A and D Lines One through 7.

5.1.3 Accomplish the requirements of 009-25 of 2.1 for a local air hose test of each new weld of the watertight/airtight structural boundary. Allowable leakage: None.

5.1.4 Inspect each protective device of the equipment listed in 1.3.1.1 through 1.3.1.5.

FOUO

SHIP: LCC-19 CHG/VER: 0/0

5.1.4.1 Verify that size and setting of each overload heater are correctly used under full load running current of the motor in accordance with Section 302g of 2.33, 2.7 and 2.11.

(V) "SIZE/SETTING"

5.1.4.2 Verify that each fuse is correctly sized in accordance with Section 302g of 2.33, 2.7 and 2.11.

(V) "SIZE"

5.2 Accomplish the requirements of 009-32 of 2.1 for each new and disturbed surface.

5.3 Notes:

5.3.1 Planner: Code 233.1 K. Uchimura, 080-9350-1432

Planner: Code 231B T. Ashina, 243-4370 Planner: Code 231B M. Maeda, 243-6101 Engineer: C250 D. Nagasato, 243-5301

5.3.2 Work Integration Manager (WIM): Code 333 T. Yaginuma, 080-5419-0598

5.3.3 SRF-JRMC will review and approve a Contractor submitted drawing or sketch and will issue additional documents with QA Form(s) relating to actual location of temporary access(es) for documentation of welding, nondestructive testing, and compartment testing when OQE(s) are required.

5.3.4 Opening, initial cleaning, closing, and installation/removal of FMEs of the following spaces will be covered by the following TGI No(s).

JP-5 (9-109-1-J): 3819P12320A01 (KTR TGI)

JP-5 Tank (9-109-4-J): 3819P12321A01 (KTR TGI) Cross Flooding Duct, Ninth Deck Frame 111: 3819P12320A01 (KTR TGI)

5.3.5 Opening, initial cleaning, and closing of the following spaces will be covered by the following TGI No(s).

Fresh Water Ballast (9-86-5-W): 3819P12343A01 (KTR TGI) Distillate Fuel or Ballast (9-121-1-F): 3819P12306A01 (KTR TGI)

5.3.6 Preservation work for new and disturbed surfaces of each space listed in 1.2.32 will be covered by TGI No.

3819P12306A01 (KTR TGI).

5.3.7 Preservation work for new and disturbed exterior surfaces of underwater hull will be covered by ICN

3819P11001 (KTR TGI).

5.3.8 Work per this instruction involves cutting an access (or removal of a door) through a fire zone bulkhead, through the hull of the ship above the turn of the bilge, through ventilation components (ducting, plenums, etc.), or through any air-tight, fume-tight or watertight bulkhead normally used to control air flow in the event of a shipboard fire. A non- flammable closure is required in accordance with COMNAVDEASYSCOM MSG R 261400Z JUL 12. The closure, if not continuously in use, shall be staged near the access, readily visible and accessible, so that any emergency responder can install the closure to affect proper air flow onboard the ship.

5.3.9 JCN EE01-L105 is related to this TGI.

5.4 Government Furnished Material (GFM):

5.4.1 All GFM listed in each S/A drawing will be provided as kitted material.

5.5 SRF-JRMC will provide the following service work: (TGI No. 3819P31002S02)

FOUO

SHIP: LCC-19 CHG/VER: 0/0

5.5.1 [C740] Crane and crane rigging service.

5.5.2 [X99E] Utilities service, electrical.

5.5.3 [X99M] Utilities service, including low pressure air supply, water supply, and steam supply.

5.5.4 [C106.1] Safety inspection for SRF-JRMC employees.

5.5.5 [C106.2] Gas free inspection for SRF-JRMC employees.

5.5.6 [C133] QA Inspection for (G) symbol(s).

FOUO

J-1

SHIP: LCC-19 CHG/VER: 0/0

APPENDIX "J"

TGI JOB SUMMARY INFORMATION SHEET

SYSTEM: PLANT NO.: COMPONENT NAME: TYPE: PHASE: REPEAT: CU PH

VERSION:

CASREP

CAT:

SA 79243K ELEC EDG#2 AY A 0 0

CU PHASE TITLE:

*(RE) F/O – S/A 79243K, ACCOMPLISH ELEC WORK FOR EDG#2, ESLP SS/EDG GENSET UPGRD

PRIMARY COMPONENT:

COMPONENT UNIT LIST (FOR ASSEMBLIES):

FOUO

J-2

SHIP: LCC-19 CHG/VER: 0/0

CKT 7309 IC K-2EG25 C- K-2EG26 C- HLN E-STOP4-109-01-L RE PMP-2E BATT

CHRGR C- (4-118-1)-1L-A17 LF (4-118-1)-1L-A3 LF 1ASSTG 28VDC DP PA 1BSSTG 28VDC DP

PA CMPT 3-120-1-A MS CMPT 7-109-1-E MS CMPT 3-113-3-L MS TRUNK 5-109-

1-T MS CMPT 8-86-0-E MSBLST 9-86-5-W TK CMPT 4-109-01-L MS CMPT 8-76-0-E MS

K-2EG135 C- DG SENSING ENCLOSURE EE LGE ENG COT PNL PA DUAL VR

RG CKT 2BC1 IC CKT TD52 IC 2E-PMP(TANK LVL IND) C- K-EC613 C- K-

2EG129 C- K-2EG130 C- K-2EG131 C- K-2EG132 C- K-2EG133 C-

K-2EG134 C- K-2EG15 C- 2EDG-4EP-2E C- K-2EG101 C- K-2EG102

C- K-2EG103 C- K-2EG105 C- K-2EG106 C- K-2EG107 C- K-2EG108

C- K-2EG110 C- (5-91-2)-4SF-A C- 5-91-2-1SF-A-1 C- 5-91-2-4SF-A-1 C- 1SSFC

CV 1SSFC EXBRC7-109-1-E ER (6-113-1)-4P-C C- 1S VIEW NODE EE 2S VIEW NODE

EE 6-114-1-1P-C RC TF 6-114-1 XF TF 7-116-1 XF TF BANK 6-111-1 XF (6-114-

1)-28P-A C- (6-114-1)-28P-B C- (6-114-1)-28P-C C- (6-114-1)-28P-G C- (7-86-4)-1P-E C- (7-86-

4)-1P-F C- 10KW UPS 7-109-1-E C- 1A DIST-28P-1A DVR C- 1A DIST-28P-1A PMP C- 1A

DIST-28P-1A SENSI C- 1A DIST-28P-1S SWBD C- 1A DIST-28P-NTWK 1B C- 1A DIST-28P-SCU C-

1A DIST-28P-VN1 C- 1B DIST-28P-1B DVR C- 1B DIST-28P-1B PMP C- 1B DIST-28P-

1B SENSI C- 1B DIST-28P-1S SWBD C- 1B DIST-28P-1SP ACBE C- 1B DIST-28P-2SP ACBE C- 1B

DIST-28P-NTWK 1B C- 1B DIST-28P-SCU C- 1B DIST-28P-VN2 C- 2E-28P-PMP C-

2E-4EP-(7-111-2) C- 5-91-2-4P-A-1 C- 5-91-2-4P-A-2 C- 5-91-2-4P-B-1 C- 5-91-2-4P-B-2

C- 5-91-2-4P-B-3 C- 5-91-2-4P-B-4 C- 6-113-1-1P-C C- 61-4P-6-113-1 C- PMP-28P-

NTWK 3A C- PMP-28P-NTWK 3B C- RECT 2A-28P-1A DIST C- RECT 2B-28P-1A DIST C-

RECT 3A-28P-1B DIST C- RECT 3B-28P-1B DIST C- RECT 5A-28P-2E DIST C- RECT 5A-28P-

PMP C- RECT 5B-28P-2E DIST C- RECT 5B-28P-PMP C- VN1-28P-NTWK B C- VN1-

28P-SCU C- VN2-28P-NTWK B C- VN2-28P-SCU C- RTRY LIGHT 8-76-0-E LF (6-113-

1)-4P-F C- (6-114-1)-28P-E C- (6-114-1)-28P-F C- 2E-4EP-A C- 6-114-1-1P-A LS C- 6-114-

1-1P-A SOL-A C- 6-114-1-1P-A SOL-B C- 6-114-1-1P-E C- K-2EG109 C- #2 EDG SW

CLG PUMP CT CKT E IC 1MC SPKR 4-109-01-L LD 6-114-1-1P-D C- IC/SM-4 ALM7-

109-1-E SB CKT 7TK IC CAMERA 7-109-1-E EE CKT 2TV IC (6-113-1)-4P-J C-

PP 6-113-1 PA PP 6-114-1 PA 4-105-2-1P-G RC PMP FUSE 6-109-1-E PA 2E-

4EP-J(PB) C- 4-130-2-1L-B1C1&B1C2 C- VNT E3-120-3 CT VNT S3-111-1 CT VNT E3-120-3 FA VNT S3-111-1 FA 2-RLY PNL 6-109-1-E PA (3-120-1)-4P-K6(SV1) C- (3-120-1)-4P-K6(SV2) C- 2E-4EP-M(PB) C- 2EA-4EP-M(PB) C- (6-118-1)-4P-K C- (4-118-1)-1L-E1A3 C- 6-35-2-24P-A1

C- 6-113-1-24P-A1 C- 6-113-1-24P-A4 C- 5-91-2-1SF-A C- BATT CONT C- BATT

NEGATIVE C- BATT NEUTRAL C- BATT POSITIVE C- GROUND C- (5-91-

2)-4P-A C- (5-91-2)-4P-B C- (6-118-1)-4P-A C- (6-118-1)-4P-B C- (6-118-1)-4P-D C- (6-118- 1)-4P-G C- (6-118-1)-4P-J C- 2E-4EP-(6-110-1)EMER C- 2EA-4EP-(7-111-2) C-61-4P-(6-110-4)(NORM C- 61-4P-(6-118-1) C- UPS1EP-5-91-2-1P-B-1 C- UPS4EP-(5-91-2)-4P-B C- UPS4EP-5-91-2-4P-B-5 C- PP 6-110-1 PA PP 6-118-1 PA (4-105-2)-1P-G RC (6-114-1)-1P-C RC (5-129-6)-1L-C LF (5-129-6)-1L-D LF 6-113-1-4P-B1 C- 6-113-1-4P-D1 C- 6-114-1-1P-G2 C- 6-114-1-4P-G3

C- CTE 6-109-1-E XF TF 6-118-1 XF TF 6-120-1 XF LDB 4-121-7 PA (4-118-1)-1L-

C2E RC (4-130-2)-1L-B1A8 RC TF 4-121-1 XF (4-118-1)-1L-A15 LF (4-118-1)-1L-C2A LF

(4-118-1)-1L-C2A&C2C LF (4-118-1)-1L-C2C LF (4-118-1)-1L-E1A1 LF(4-118-1)-1L-E1A7 LF(4-118- 1)-1L-F1A LF (4-130-2)-1L-B1A8 LF 4-130-2-1L-B1A2&B1A4 LF 4-180-2-1L-B1A1&B1A3 LF

LSSHOF-150 C- (6-110-1)-4P-A(INTLK C- (6-114-1)-1P-A C- (6-114-1)-1P-A LS C- (6-114- 1)-1P-A SOL-A C- (6-114-1)-1P-A SOL-B C- (6-114-1)-1P-E C- (6-118-1)-4P-F C- (6-114-1)-1P-D C- (6-110-1)-1P-C(CONT1 C- (6-110-1)-1P-C(CONT2 C- (6-110-1)-1P-C(OT1) C- (6-110-1)-1P- C(OT2) C- (6-110-1)-1P-C(TS) C- (6-110-1)-4P-B C- (6-110-1)-4P-D C- CONTACTOR 3-110-1 RE

CONTACTOR 3-110-3 RE (3-120-1)-4P-K5 C- (3-120-1)-4P-K6 C- (3-120-1)-4P-K6(CONT C- (3-120-1)-4P-K6(TS) C- (3-120-1)-4P-K6INTLK C- (4-130-2)-1L-B1C1 C- (4-130-2)-1L-B1C2 C- (4-130-2)-1L-B1C7 C- (4-130-2)-1L-B1C8 C- (6-110-1)-1P-C(CONT) C- (6-110-1)-1P-C(CTR) C- (6-110-1)-4P-A C- (6-110-1)-4P-A(HALON C- (6-110-1)-4P-A(PB) C- (6-110-1)-4P-C C- (6-110-

1)-4P-C(CT) C- (6-110-1)-4P-C(HALON C- (6-110-1)-4P-C(PB) C- (6-110-1)-4P-C(RLY) C- 2E-

4EP-H C- 2E-4EP-H(HALON) C- 2E-4EP-H(PB) C- 2E-4EP-J C- 2E-4EP-

J(HALON) C- 2E-4EP-J(INTLK) C-2E-4EP-J(MLS) C- #2 EDG ENGINE EN (4-130-2)-1L-

B1A11 C- (6-118-1)-4P-B C- 2EG-4EP-2E C- 2PLMC-2SSEDG C- 2SSEDG-DLOP

C- 2SSEDG-DPS C- 2SSEDG-GLOP C- 4-130-2-1L-B1A11 HTR C- 6-113-1-4P-B2 C-

6-113-1-4P-D2 C- 6-113-1-4P-G C- 6-114-1-1P-G4 C- 6-114-1-1P-G5 C-

EDG224PEMERSHUTDOW1A C- K-2EG-1 C- K-2EG11 C- K-2EG111 C-

K-2EG112 C- K-2EG114 C- K-2EG123 C- K-2EG124 C- K-2EG27

C- K-EG-209 C- K-EG-210 C- K-EG-211 C- K-EG-212 C- K-EG-217

C- K-EG-219 C- K-EG-230 C- MPU-2SSEDG(MPU) C- PMP-2PLMC C- PMP-

2SSEDG MPU-1 C- PMP-2SSEDG(COM 1) C- PMP-2SSEDG(COM) C- PMP-2SSEDG(COM2) C-

#2EDG PRE-LUBE MO CT #2EDG CAT PANEL PA 2E-1P-PMP C- 2E-1P-PMP RECT 5A

C- 2E-1P-PMP(CNTRL-1) C- 2E-1P-PMP(CNTRL-2) C- 2E-1P-PMP(SENS) C- 2E-4EP-CPT

C- 2E-4P-PMP UPS6 C- 2S-4P-2E C- K-2EG14 C- K-2EG16 C- K-

2EG17 C- K-2EG18 C- K-2EG19 C- K-2EG20 C- K-2EG21 C-

K-2EG23 C- K-2EG24 C- K-EC600 C- K-EC601 C- K-EC602

C- K-EC604 C- K-EC605 C- K-EC606 C- K-EC607 C- K-EC608

C- NTWK 3A-28P-DC(ALT) C- NTWK 3B-28P-DC(ALT) C- PMP-2E(COM) C- (4-130-2)-1L-B1A11 CB (6-114-1)-1P-F CB #2EDG JKTWH CR ENL#1 MQ #2EDG JKTWH CR ENL#2 MQ (4-130-2)-1L-B1A11

C- #2EDG BTRY#1 BA #2EDG BTRY#2 BA #2EDG BTRY#3 BA #2EDG

BTRY#4 BA 2EDG BATCHG7-109-1-E BC (6-114-1)-1P-F C- (6-118-1)-2P-A C- (6-118-1)-4P-A

C- 6-113-1-4P-A C- K-2EG113 C- K-2EG115 C- K-2EG116 C- K-2EG117

C- K-2EG118 C- K-2EG119 C- K-2EG12 C- K-2EG120 C- K-2EG121

C- K-2EG122 C- K-2EG125 C- K-2EG126 C- K-2EG127 C- K-2EG128

C- K-2EG13 C- K-2EG26 C- K-EC610 C- K-EC611 C- K-EC612

C-

FOUO

J-3

SHIP: LCC-19 CHG/VER: 0/0

ATTACHMENT LIST:

1. ENCLOSURE-01 (3819P31002A01-Engrg Inst.pdf) saved on 13-FEB-2025 0000.

ZONE MANAGER: ZONE: COMPARTMENT: LEVEL: FRAME: SIDE:

YAGINUMA ,TAKEHIDE

JO: KO: TOTAL MAN HRS: PLANNING ACCEPTANCE:

3819P31002 A01

TOTAL MAT’L COST TOTAL DURATION:

CU PHASE DESCRIPTION:

The purpose of this TGI to accomplish electrical work for emergency diesel generator No. 2, extended service life program ship service/emergency diesel generator generator-set, upgrade.

Location of Work:

Emergency Generator Room No. 2 (7-109-1-E) Fan Room (2-109-3-Q) Passage (3-109-5-L) Female Officers Head (3-109-7-L) After Deck Gear Locker (3-109-11-Q) State Room (3-111-1-L) Fan Room (3-111-1-Q) State Room (3-113-3-L) X1 Store Room (3-120-1-A) Fan Room (3-120-1-Q) Damage Control Central (4-81-1-Q) Snap II Computer Room (4-103-2-Q) Load Center Switchboard Room No. 6 (4-107-3-Q) Passage (4-109-01-L) Air Conditioning and Refrigeration Shop (4-109-3-Q) Interior Communication and Gyro Room No. 2 (5-86-0-C) Trunk (5-86-2-T) Crew Living Space (5-109-0-L) Trunk (5-109-1-T) Physical Fitness Room (5-121-2-L) Engine Room Enclosed Operating Station (6-86-0-E) Self Service Storeroom (6-86-1-A) Crew Living Space (6-98-0-L) Emergency Switchgear Room No. 2 (6-109-1-E) Trunk (6-117-0-T) Deck Department Cleaning Gear Storeroom (6-118-1-A) 400 Hz Equipment Room (6-118-1-Q) Pump Room No. 2 and Air Conditioning and Machinery Room No. 2 (7-109-2-E) Fire Room (8-76-0-E) Engine Room (8-86-0-E) Fresh Water Ballast (9-86-5-W) Shaft Alley (9-98-0-Q)

JP-5 (9-109-1-J)

JP-5 (9-109-4-J)

Distillate Fuel or Ballast (9-121-1-F) Cross Flooding Duct, Ninth Deck Frame 111 Underwater Hull Weather, Frames between 95 and 112, Starboard

TASK NAME

SHOP TSD/WC TS CREW# MHRS

HIGH RAD

HOURS

RC

GRID#

5.1 ELEC , INSL , PNTR , SFTR , WELD , CARP , QA 22 KE PC

5.2 PNTR , QA 22 KE PC

FOUO

J-4

SHIP: LCC-19 CHG/VER: 0/0

TASK NAME

SHOP TSD/WC TS CREW# MHRS

HIGH RAD

HOURS

RC

GRID#

Electrical Work CFM: for air compressor rental cost, fuel oil cost, asbestos sample and analysis cost, banding material, fasteners, insulation tape, plastic bags, rope, and other consumable.

22 MQ CS

Structure Work CFM: for all paint, thinner, grits including disposal cost, fire watch and confined space watch, air compressor rental cost and fuel oil cost for air hose test, lead sampling/analysis cost, stud pin, adhesive for pin, covering and enclosing material, asbestos sample and analyze cost, and MISC such as ---continue to below---

22 MQ CS

---continued from above--- electrode, gases, temporary closure, covering material, and other consumable.

22 MQ CS

Temporary Access Work CFM for fire watch, air compressor rental cost and fuel oil cost for air hose test, and MISC such as electrode, gases, temporary closure, covering material, and other consumable.

22 MQ CS

Process Funding Document. 10 CT OM

FOUO

M-1

SHIP: LCC-19 CHG/VER: 0/0

APPENDIX “M”

TGI MATERIAL LIST

SYSTEM: PLANT NO.: COMPONENT NAME: TYPE: PHASE: REPEAT: CU PH

VERSION:

CASREP

CAT:

SA 79243K ELEC EDG#2 AY A 0 0

CU PHASE TITLE:

*(RE) F/O – S/A 79243K, ACCOMPLISH ELEC WORK FOR EDG#2, ESLP SS/EDG GENSET UPGRD

MATERIAL REFERENCES

REF

NO.

DOCUMENT/DRAWING

NUMBER

DOCUMENT/DRAWING TITLE REV

1 ELM-250189

2 113-5293062 E

JOB ORDER: KEY OP:

3819P31002 A01

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

001 1 1 M STUFFING TUBE, ORDER FOR

KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 010156930 NA 4 N 50455350 1/EA

002 2 1 M STUFFING TUBE, ORDER FOR

KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 010149933 NA 4 N 50455077 1/EA

003 3 1 M PIPE,METALLIC, ORDER FOR

KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 4710 009935037 NA 4 N 50455231 10/FT

004 4 1 M BAR,METAL, ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 9510 001891556 NA 4 N 50455300 2/FT

NOTES:

FOUO

M-2

SHIP: LCC-19 CHG/VER: 0/0

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

005 5 1 M PAD, TAPPED ROUND, PAD,

TAPPED ROUND, 1/4"-20UNC-

2B X 1"LG, STEEL, CARBON,

AISI-1020, CENTERED,

CONCENTRIC INTERNAL

THREAD THRU HOLE 5/8" OD,

FINISH: PLAIN.

BIW CATALOG NO.53204-155

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

LL9003506 NA 4 N

100/EA

006 6 1 M PAD, TAPPED ROUND, PAD,

TAPPED ROUND,

CENTERED, CONCENTRIC

INTERNAL THREAD THRU

HOLE 3/4" OD,

SIZE: 3/8-16UNC-2B X 1" LG,

MATL: STEEL, CARBON, AISI-

1020, FINISH: PLAIN,

BIW CATALOG NO. 53204-040,

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5340 LL9306697 NA 4 N 50457601 50/EA

007 7 1 M PAD, TAPPED ROUND, PAD,

TAPPED ROUND,

CENTERED, CONCENTRIC

INTERNAL THREAD THRU

HOLE 5/8" OD,

SIZE: 5/16-18UNC-2B X 1" LG,

MATL: STEEL, CARBON, AISI-

1020, FINISH: PLAIN,

BIW CATALOG NO. 53204-015,

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

NA 4 N 20/EA

008 8 1 M PAD, TAPPED ROUND, ORDER

FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5315 LL9307892 NA 4 N 50457474 50/EA

009 9 1 M SHEET,METAL, ORDER FOR

KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 9515 015087795 NA 4 N 50455353 1/SH

010 10 1 M BAR,METAL, ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 9510 001891590 NA 4 N 50455355 10/FT

011 11 1 M STUD,WELDING, STUD,

WELDING, WITH ARC SHIELD

(FERRULE).

TYPE: CPL, PARTIALLY

THREADED.

MIL-S-24149/1 TYPE II CLASS I,

ZE: 1/2-13UNC-2A X 3"LG

MATL: STEEL, ZINC COATED

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

LL9310755 NA 4 N 20/EA

012 12 1 M ANGLE,STRUCTURAL, ORDER

FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

3B 9520 009545666 NA 4 N 50455357 5/FT

013 13 1 M BUSHING,ELECTRICAL,

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 005782859 NA 4 N 50455359 3/EA

FOUO

M-3

SHIP: LCC-19 CHG/VER: 0/0

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

014 14 1 M CONDUIT OUTLET, ORDER

FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 011845832 NA 4 N 50455362 2/EA

015 15 1 M CONDUIT OUTLET, ORDER

FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 008395324 NA 4 N 50455364 1/EA

016 16 1 M GASKET, ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5330 012342617 NA 4 N 50455368 3/EA

017 17 1 M COVER,CONDUIT, COVER,

CONDUIT, 1", STEEL, FOR

CONDUIT BODY, 1", P/N:

LB100M.

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 LL9308962 NA 4 N 50457631 3/EA

018 18 1 M LOCKNUT,ELECTRICAL,

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 5975 007148031 NA 4 N 50455370 13/EA

019 19 1 M PIPE,METALLIC, ORDER FOR

KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 4710 002775473 NA 4 N 50455078 10/FT

020 20 1 M PLATE,METAL, SIZE: 3 FT X 2

FT,

ORDER FOR KTR

ORIG: C226 K.YAMAMI, 080-

9350-1447

9B 9515 001533217 NA 4 N 50455209 6/SF

100 M INSULATI, ORDER FOR KTR,

ORIG C231B M. MAEDA, 243-

9Q 5640 008096312 NA 4 N 50455280

179/EA

101 M INSULATI, ORDER FOR KTR,

ORIG C231B M. MAEDA, 243-

9Q 5640 008096315 NA 4 N 50455282 15/EA

102 M SOUND CO, ORDER FOR KTR,

ORIG C231B M. MAEDA, 243-

9Q 5640 007565866 NA 4 N 50455283 2/SE

103 M ADHESIVE, ORDER FOR KTR,

ORIG C231B M. MAEDA, 243-

9B 8040 002738708 NA 4 Y 50455045 8/GL

104 M TAPE,TEX, ORDER FOR KTR,

ORIG C231B M. MAEDA, 243-

9B 8315 002671632 NA 4 N 50455284 15/RO

105 M TAPE,TEX, ORDER FOR KTR,

ORIG C231B M. MAEDA, 243-

9B 8315 002671633 NA 4 N 50455285 5/RO

150 2 M ANGLE,STRUCTURAL, ORDER

FOR KTR

ORIG: C226 H.SHIMIZU, 080-

9350-1431

3B 9520 009545666 NA 4 N 50455374 20/FT

151 2 M ANGLE,STRUCTURAL, ORDER

FOR KTR

ORIG: C226 H.SHIMIZU, 080-

9350-1431

3B 9520 009545666 NA 4 N 50455386 20/FT

152 2 M STRIP,METAL, ORDER FOR

KTR

ORIG: C226 H.SHIMIZU, 080-

9350-1431

9B 9515 002043964 NA 4 N 50455389 10/FT

FOUO

M-4

SHIP: LCC-19 CHG/VER: 0/0

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

153 2 M PLATE,ME, SIZE: 2 FT X 6 FT,

ORDER FOR KTR

ORIG: C226 H.SHIMIZU, 080-

9350-1431

9B 9515 002375333 NA 4 N 50455210 11/SF

FOUO: Public availability to be determined under 5 USC 552 SHEET_____OF_____

☐ NUCLEAR APPENDIX "D"

DEFICIENCY FORM

☐ NON-NUCLEAR

1. SHIP/HULL NO.: 2a. DL or DR No.

(Circle One)

2b. REVISION: 3a. COMPONENT NAME: 3b. TYPE: 3c. PHASE: 3d. REPEAT:

LCC-19 SA 79243K ELEC EDG#2 AY A 0

4a. ICN: 4b. KEY OP: 5. LOC SPACE/LVL: FRAME: P/S/C: 6. CAUSED BY:

3819P31002 A01

7. DESCRIPTION:

8. ORIGINATOR: NAME: BADGE: SHOP/CODE: DATE: PHONE NO.:

9. CORRECTIVE ACTION:

10. EVALUATOR: NAME: BADGE: SHOP/CODE: DATE: PHONE NO.:

FOR NON-NUCLEAR USE ONLY

11. RFD/RFW REQ’D ☐ LAR REQ'D ☐

ILS MOD REQ’D ☐

SRD/PLAN REV REQ'D ☐

DWG NO.: _____________________ S/A NO.: ___________________

12. ISOLATION SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.:

SATISFACTORY:

13. SUBSAFE OQE RECORD? SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

YES ☐ NO ☐

14. CORRECTIVE ACTION SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

COMPLETE:

15. INSPECTION REQ’D? INSPECTION COMPLETE/SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

_________:YES ☐ NO ☐

16. RECORDS REVIEW SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

COMPLETE (DR ONLY)

DL’s ISSUED

(DR ONLY)

FOUO: Public availability to be determined under 5 USC 552 SHEET_____OF_____

☐ NUCLEAR Deficiency Form Continuation Sheet ☐ NON-NUCLEAR

1. SHIP/HULL NO.: 2a. DL or DR No.

(Circle One) 2b. REVISION: 3a. COMPONENT NAME: 3b. TYPE: 3c. PHASE: 3d. REPEAT:

LCC-19 SA 79243K ELEC EDG#2 AY A 0

3819P31002A01 ENCLOSURE-01 Sheet 1 of 2

AutoCAD SHX Text SUBJECT: SUPPLEMENTAL INFO FOR INSTALLATION OF FDN FOR POWER PANEL SUPPLEMENTAL INFO FOR INSTALLATION OF FDN FOR POWER PANEL (6-118-1) INCID TO SCD 9243 INCID TO SCD 9243 ICN:3819P31002 3819P31002 19P31002 9P31002 JCN: EE01-L105 EE01-L105 L105 ORIGINATOR: C250 T. UKIGAI GINATOR: C250 T. UKIGAI INATOR: C250 T. UKIGAI C250 T. UKIGAI T. UKIGAI . UKIGAI UKIGAI DATE: 2/4/2025 2/4/2025 /4/2025 4/2025 /2025 5 REFERENCES: S: : (a) LCC19-345-8574538 "B", SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 ) LCC19-345-8574538 "B", SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 LCC19-345-8574538 "B", SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 -8574538 "B", SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 8574538 "B", SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 , SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 SCD 9243 GENSET UPGRADE EQUIPMENT ARRANGEMENT EDG RM 2 EMENT EDG RM 2 MENT EDG RM 2 & EMER SWITCHGEAR RM 2 & EMER SWITCHGEAR RM 2 EMER SWITCHGEAR RM 2 AR RM 2 R RM 2 (b) STD-113-5293062 "E", PSNS STANDARD FOUNDATIONS - MISC ELECTRICAL EQUIPMENT FOR "E", PSNS STANDARD FOUNDATIONS - MISC ELECTRICAL EQUIPMENT FOR "E", PSNS STANDARD FOUNDATIONS - MISC ELECTRICAL EQUIPMENT FOR PSNS STANDARD FOUNDATIONS - MISC ELECTRICAL EQUIPMENT FOR PSNS STANDARD FOUNDATIONS - MISC ELECTRICAL EQUIPMENT FOR GRADE A & B SHOCK GRADE A & B SHOCK GRADE A & B SHOCK (c) AGC19-103-2491034 "H", 1ST & 2ND PLATF PLTG AFT FR 98 C19-103-2491034 "H", 1ST & 2ND PLATF PLTG AFT FR 98 103-2491034 "H", 1ST & 2ND PLATF PLTG AFT FR 98 "H", 1ST & 2ND PLATF PLTG AFT FR 98 H", 1ST & 2ND PLATF PLTG AFT FR 98 ", 1ST & 2ND PLATF PLTG AFT FR 98 , 1ST & 2ND PLATF PLTG AFT FR 98 1ST & 2ND PLATF PLTG AFT FR 98 1ST & 2ND PLATF PLTG AFT FR 98 NOTES: 1. THE PURPOSE OF THIS ENGINEERING INSTRUCTION IS TO PROVIDE SUPPLEMENTAL INFORMATION THE PURPOSE OF THIS ENGINEERING INSTRUCTION IS TO PROVIDE SUPPLEMENTAL INFORMATION FOR INSTALLATION OF FDN FOR POWER PANEL (6-118-1, ITEM NO.52) INCIDENTAL TO SCD 9243 OF FDN FOR POWER PANEL (6-118-1, ITEM NO.52) INCIDENTAL TO SCD 9243 OF FDN FOR POWER PANEL (6-118-1, ITEM NO.52) INCIDENTAL TO SCD 9243 OF USS BLUE RIDGE (LCC 19). 19). 19). 2. FDN FOR POWER PANEL (6-118-1) SHOWN ON PLAN 29-A OF SHEET 4 OF REF (a) SHALL BE FDN FOR POWER PANEL (6-118-1) SHOWN ON PLAN 29-A OF SHEET 4 OF REF (a) SHALL BE (6-118-1) SHOWN ON PLAN 29-A OF SHEET 4 OF REF (a) SHALL BE SHOWN ON PLAN 29-A OF SHEET 4 OF REF (a) SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH ELEVATION VIEW 24-B, PLAN 24-D-TYPE 8A INSTALLED IN ACCORDANCE WITH ELEVATION VIEW 24-B, PLAN 24-D-TYPE 8A SHOWN ON SHEET 3 OF REF (b) AND PLAN 2-A OF THIS ENGINEERING INSTRUCTION. ENGINEERING INSTRUCTION. . 3. ALL WELDING FOR STEEL MATERIALS SHALL BE CONDUCTED IN ACCORDANCE WITH SRF-JRMC ALL WELDING FOR STEEL MATERIALS SHALL BE CONDUCTED IN ACCORDANCE WITH SRF-JRMC PROCESS INSTRUCTION NO.100-2 OR TABLE 2 OF NAVSEA STD ITEM NO.009-12 RESPECTIVELY. AFTER ALL WELDING, VT SHALL BE REQUIRED IN ACCORDANCE WITH PARAGRAPH 6.4 OF VT SHALL BE REQUIRED IN ACCORDANCE WITH PARAGRAPH 6.4 OF IN ACCORDANCE WITH PARAGRAPH 6.4 OF MIL-STD-1689. 5. FOR INFORMATION OF POWER PANEL NOT SHOWN ON THIS INSTRUCTION, SEE REF (a). FOR INFORMATION OF POWER PANEL NOT SHOWN ON THIS INSTRUCTION, SEE REF (a). POWER PANEL NOT SHOWN ON THIS INSTRUCTION, SEE REF (a). INSTRUCTION, SEE REF (a). , SEE REF (a). 6. FOR INFORMATION OF FDN FOR POWER PANEL NOT SHOWN ON THIS INSTRUCTION, SEE REF (b). FOR INFORMATION OF FDN FOR POWER PANEL NOT SHOWN ON THIS INSTRUCTION, SEE REF (b). NOT SHOWN ON THIS INSTRUCTION, SEE REF (b). INSTRUCTION, SEE REF (b). , SEE REF (b). 7. FOR INFORMATION OF HULL STRUCTURE NOT SHOWN ON THIS INSTRUCTION, SEE REF (c).FOR INFORMATION OF HULL STRUCTURE NOT SHOWN ON THIS INSTRUCTION, SEE REF (c). NOT SHOWN ON THIS INSTRUCTION, SEE REF (c).INSTRUCTION, SEE REF (c)., SEE REF (c).

AutoCAD SHX Text_1

ENGRG INST

AutoCAD SHX Text_2

LIST OF MATERIAL

AutoCAD SHX Text_3

PC NOC NO

AutoCAD SHX Text_4

DESCRIPTIONESCRIPTION

AutoCAD SHX Text_5

QTYTY

AutoCAD SHX Text_6

MATERIAL

AutoCAD SHX Text_7

SPECPEC

AutoCAD SHX Text_8

REMARKSEMARKS

AutoCAD SHX Text_9

AutoCAD SHX Text_10 3 x 3 x 1/4 L

AutoCAD SHX Text_11

5 LF LFLFF

AutoCAD SHX Text_12

STEEL (OS)

AutoCAD SHX Text_13

MIL-S-22698 GR A

AutoCAD SHX Text_14

AutoCAD SHX Text_15

PLATE, 7.65#LATE, 7.65#7.65#

AutoCAD SHX Text_16

1 SF SF

AutoCAD SHX Text_17

STEEL (OS)

AutoCAD SHX Text_18

MIL-S-22698 GR A

3819P31002A01 ENCLOSURE-01 Sheet 2 of 2

AutoCAD SHX Text_19

ENGRG INST

AutoCAD SHX Text_20 L-5 (S) 10 x 5 3/4 x 29# I-T, MS (TYP)

AutoCAD SHX Text_21 L-6 (S)

AutoCAD SHX Text_22 L-7 (S)

AutoCAD SHX Text_23

FAB & INSTL POWER PANEL FDN NOT SHOWN 1ST PLATF (S) SCALE: 1 1/2"=1'-0

AutoCAD SHX Text_24

PLAN 2-A

AutoCAD SHX Text_25

WTRTT TRANSV BHD, STBD

AutoCAD SHX Text_26

AutoCAD SHX Text_27

AutoCAD SHX Text_28

TYP

AutoCAD SHX Text_29

12.75# MS

AutoCAD SHX Text_30

TYP

AutoCAD SHX Text_31 3/16

AutoCAD SHX Text_32

AutoCAD SHX Text_33

SEE DET 2-B LOC TO SUIT NEW FDN (TYP)

AutoCAD SHX Text_34

CHOCK LKG INBD (TYP) SCALE: 3"=1'-0

AutoCAD SHX Text_35

DET 2-B

AutoCAD SHX Text_36

AutoCAD SHX Text_37

1ST PLATF 12.75# MS

AutoCAD SHX Text_38 1/8/88

AutoCAD SHX Text_39 SNIPE 1/4 x 1/4

AutoCAD SHX Text_40

AutoCAD SHX Text_41

ABT 5 (TYP)

AutoCAD SHX Text_42

FWD

AutoCAD SHX Text_43

AutoCAD SHX Text_44 POWER PANEL FDN SEE REF (b)

File details come from the government source that posted it. Updated .