Station_No._2_Reroof_-_Drawings.pdf
PDF 582 KB Posted
- Solicitation number
- ITB-34-2026
- Issued by
- Rutherford County, Tennessee
About this file
This architectural drawing document, prepared by Johnson + Bailey Architects P.C. for the City of Murfreesboro Fire & Rescue Department, provides detailed roof plans and specifications for the reroofing of Fire Rescue Station No. 2 located at 2880 Runnymeade Drive, Murfreesboro, Tennessee. The project involves complete removal of existing asphalt shingle roofing, gutters, and downspouts, with installation of new Class A fire-rated asphalt shingles, underlayment, metal flashing, gutters, and downspouts. The drawings include a roof demolition plan, roof plan for new work, roof underlayment plan, and multiple detailed sections showing gutter installations, flashing details, pipe vent seals, and downspout configurations. Substantial completion is required within 30 calendar days of the written Notice to Proceed, with sealed bids due by 2:00 PM CST on Thursday, April 23, 2026. A mandatory pre-bid conference is scheduled for Thursday, April 9, 2026, at 10:00 AM at the fire station.
Bidders must submit sealed electronic bids through the City's OpenGov procurement portal on a lump sum basis with unit price proposals for replacement of damaged roof sheathing up to 300 square feet. Bidders must be licensed general contractors in Tennessee and submit 5% bid security along with performance and payment bonds each equal to 100% of the contract sum. Comprehensive insurance coverage requirements include $2,000,000 combined general liability per occurrence, $1,000,000 commercial auto liability, $1,000,000 pollution liability, $1,000,000 professional liability, and a $5,000,000 umbrella policy. Liquidated damages are assessed at $200 per calendar day for delays. Proposals must be maintained for 45 consecutive calendar days from submission, and the contract must be executed within 5 consecutive calendar days of written acceptance. Contractors and subcontractors employing five or more workers must submit executed Drug-Free Workplace Affidavits, and all bidders must certify compliance with Tennessee's Iran Divestment Act and non-boycott of Israel requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Johnson + Bailey Architects P.C.
34 35 36
Architectural
Index
Rescue Department Murfreesboro Fire &
ROOF PLAN AND DETAILSA1.1
ROOF UNDERLAYMENT PLANA1.2Station No. 2 Reroofing of
R e r o o f in g o f
S t a t io n
N o
R u n n y m e a d e
D r iv e
M u r f r e e s b o o
F ir
R s c u
D p t
J
B
P o j e c t
N o
Murfreesboro, TN 37127 2880 Runnymeade Drive
PROJECT ADDRESS:
"8 570'-2
"2 18'-6
"4 310'-4
88'-9"
"8 510'-4
7"
5"
"2
A1.1
2DETAIL
A1.1 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
3DETAIL
A1.1 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
1DETAIL
A1.1 06" 6"
SCALE 6" = 1'-0"
12"3"
04'
SCALE 1/8" = 1'-0"
16'8'8'
ROOF PLAN - NEW WORK
N O
R T
H
PLAN
04'
SCALE 1/8" = 1'-0"
16'8'8'
ROOF PLAN - DEMOLITION
THIS DRAWING SHALL NOT BE
REPRODUCED, PUBLISHED, OR USED
IN ANY WAY WITHOUT THE WRITTEN
PERMISSION OF THE ARCHITECT.
PROJECT N0.
DATEREVISION
CHECKED BY
DRAWN BY
DATE
NOTES:
K.S.P.
B.D.S.
02-12-26
& RESCUE DEPARTMENT
MURFREESBORO FIRE
MURFREESBORO, TN
Drive)
(Runnymeade
Station No. 2
Reroofing of
WALL BELOW
OUTLINE OF BUILDING
8:12
8:12
8:12
8:128:128:12
6:12 6:12
6:12
6:12
6:12
GUTTER - 1/A1.1
NEW 6"x6" METAL
DOWNSPOUT (TYP)
NEW 4"x5" METAL A1.1
A1.1
A1.1
A1.2
SEE 4/A1.1
PIPE VENT
EXISTING
ON UNDERLAYMENT
NEW SHINGLES
DOWNSPOUT STUB
NEW 4"x5" METAL
DOWNSPOUT STUB
NEW 4"x5" METAL
DOWNSPOUT STUB
NEW 4"x5" METAL
DOWNSPOUT (TYP)
NEW 4"x5" METAL
TO REMAIN
FLASHING
EXIST. STEP
TO REMAIN
FLASHING
EXIST. STEP
TO REMAIN
EPDM ROOF
EXISTING
A1.1
A1.1
A1.2
A1.1
A1.2
A1.1
SPLASHBLOCKS
TWO NEW CONC.
TO REMAIN
ROOF VENTILATOR
EXISTING POWER
TO REMAIN
ROOF VENTILATOR
EXISTING POWER
TO REMAIN
ROOF VENTILATOR
EXISTING POWER
DOWNSPOUTS
GUTTERS AND
REMOVE EXISTING
ROOFING MATERIALS.
FOR INSTALLTION OF NEW
EXISTING ROOF SHEATHING
UNDERLAYMENT - PREPARE
SHINGLE ROOFING AND
REMOVE ALL EXISTING
DOWNSPOUTS
GUTTERS AND
REMOVE EXISTING
TO REMAIN
ROOF VENTILATOR
EXISTING POWER
THE BOTTOM OF DOWNSPOUTS WITH NEW UNITS TO MATCH EXISTING.
REPLACE EXISTING VINLY TRANSITION SLEEVES AT 1)
NOTES:
2/A1.2
PIPE SEAL - SEE DETAIL
TO REMAIN. INSTALL NEW
EXISTING PIPE VENT
2/A1.2
SEE DETAIL
PIPE VENT
EXISTING
(CONTINUOUS)
METAL GUTTER
NEW PRE-FINISHED
SEE DETAIL 1/A1.1
NEW METAL GUTTER
ON LEAK BARRIER
NEW SHINGLES
EXIST. DRAINAGE SYSTEM
EXTEND & CONNECT TO
NEW METAL DOWNSPOUT
WITH MILD SOAP & WATER
EAVE & FASCIA COVERS
CLEAN ALL EXISTING METAL
SEE DETAIL 1/A1.1
NEW METAL GUTTER
ON LEAK BARRIER
NEW SHINGLES
STUB
NEW METAL DOWNSPOUT
WITH MILD SOAP & WATER
EAVE & FASCIA COVERS
CLEAN ALL EXISTING METAL
A1.2
N O
R T
H
PLAN
04'
SCALE 1/8" = 1'-0"
16'8'8'
ROOF UNDERLAYMENT PLAN
1DETAIL
A1.2 06" 6"
SCALE 6" = 1'-0"
12"3"
CONDITION
DEMOLITION
CONDITION
CONSTRUCTION
NEW
2DETAIL
A1.2 06" 6" 1'3"
SCALE 1 1/2" = 1'-0"
THIS DRAWING SHALL NOT BE
REPRODUCED, PUBLISHED, OR USED
IN ANY WAY WITHOUT THE WRITTEN
PERMISSION OF THE ARCHITECT.
PROJECT N0.
DATEREVISION
CHECKED BY
DRAWN BY
DATE
NOTES:
K.S.P.
B.D.S.
02-12-26
& RESCUE DEPARTMENT
MURFREESBORO FIRE
MURFREESBORO, TN
Drive)
(Runnymeade
Station No. 2
Reroofing of
LEAK BARRIER
SHINGLE UNDERLAYMENT
ROOF UNDERLAYMENT LEGEND
EXISTING TAPERED
RIGID ROOF INSULATION
TO REMAIN EXISTING PLYWOOD
ROOF DECK TO REMAIN
EXISTING WOOD
ROOF TRUSSES
TO REMAIN
REMOVE EXISTING SHINGLES
& UNDERLAYMENT
CUT AND REMOVE PORTION
OF EXISTING EPDM
FLASHING AS SHOWN
EXISTING PLYWOOD
ROOF DECK TO REMAIN
EXISTING WOOD
ROOF TRUSSES
TO REMAIN
NEW SHINGLES ON
LEAK BARRIER
INSTALL NEW CARLISLE
EPDM FLASHING- INSTALLATION
TO BE BY A CERTIFIED
FIRESTONE EPDM INSTALLER
EXISTING TAPERED
RIGID ROOF INSULATION
TO REMAIN
REMOVE EXISTING METAL FLASHING
& CONT. RETAINER CLIP INSTALL NEW PREFINISHED
METAL FLASHING & CONT.
RETAINER CLIPEXISTING CARLISLE
EPDM ROOFING TO REMAIN
(PROTECT FROM DAMAGE)
EXISTING CARLISLE
EPDM ROOFING TO REMAIN
(PROTECT FROM DAMAGE)
1•" - 6•" DIA.
MASTIC
NEW WATER CUT-OFF
VENT PIPE
EXISTING
PIPE SILL
NEW PRE-MOLDED
PLYWD. DECK
EXISTING
TRUSS BEYOND
EXISTING
NOT BE CUT TO FIT DIA.
BE SIZED TO V.T.R. & SHALL
1. PRE-MOLDED PIPE SEAL TO
NOTES:
ON UNDERLAYMENT
NEW SHINGLES
| 2523_zCover |
| 2523_zA11 |
| 2523_zA12 |
File details come from the government source that posted it. Updated .