SR604_OEH-8P_W Keller-Tank Details.pdf

PDF 200 KB Posted

Attached to
Aerobic Aeration System Highland, Kansas
Solicitation number
246-25-Q-0074
Issued by

About this file

The document is a detailed technical diagram for a 1,250-gallon dual compartment septic tank system designed for the Indian Health Service's Holton Field Office in Kansas. The schematic provides specific engineering specifications including an aerobic air pump housing with a 600 GPD flow rate, 100 feet of 3/4-inch HDPE pipe, an effluent assembly with filter and lift handle, and an air diffuser. The diagram breaks down tank compartment dimensions and volumes, with labeled sections ranging from 14 to 750 gallons across primary treatment and aeration chambers. The technical drawing is dated 5/8/2025 and is part of a project for installing a septic aerobic treatment unit, with the drawing prepared by Jim Shene and checked by Ted Schuler from the Indian Health Service's Office of Environmental Health & Engineering.

View the file

Other files

File Type Posted
ks4.txt TXT text file
SOW for ATU and Sewer Line Replacement.pdf PDF
IHS IEE Representation Form_Jan 2022_508 Compliant.pdf PDF
SR604_Bid Sheet_W Keller.pdf PDF
SR604_OEH-8P_W Keller-OEH-8P.pdf PDF
RFQ246-25-Q-0074-SF18 and Clauses.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

IN

D

IA

N

HEA LTH SER

V

ICE

1 9 5 5

AutoCAD SHX Text invert inlet 4" PVC Pipe

AutoCAD SHX Text

HDPE RISERS WITH LIDS TO BE TERMINATED 2" BELOW FINISHED GRADE.

AutoCAD SHX Text

EFFLUENT ASSEMBLY WITH FILTER AND LIFT HANDLE

AutoCAD SHX Text SIDE VIEW A - 14 TO 16 INCHES B - 17 TO 19 INCHES C - 3 INCHES BETWEEN INLET AND OUTLET D - 750 GALLONS- PRIMARY TREATMENT CHAMBER E - 500 GALLONS - AERATION CHAMBER F - AIR GAP 2 INCHES

AutoCAD SHX Text 6in. by 6in. 10 guage wire Mesh

AutoCAD SHX Text

1,250 GALLONN DUAL COMPARTMENT SEPTIC TANK

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text

VENTED AIR PUMP HOUSING

AutoCAD SHX Text

AIR DIFFUSER

AutoCAD SHX Text

ALARM/CONTROL PANEL

AutoCAD SHX Text

ELECTRICAL POWER SUPPLY TO EXISTING BREAKER PANEL ON POWER POLE

AutoCAD SHX Text

AEROBIC AIR PUMP FOR 600GPD FLOW RATE

AutoCAD SHX Text

100 FEET OF 3/4-INCH HDPE PIPE

AutoCAD SHX Text A

AutoCAD SHX Text

3/4-INCH SCH. 40 PIPE AND FITTINGS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

INITIALS

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

OFFICE OF ENVIRONMENTAL

AutoCAD SHX Text

SANITATION FACILITY CONSTRUCTION

AutoCAD SHX Text

HEALTH & ENGINEERING

AutoCAD SHX Text

LAYOUT NAME:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJ ENG:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

HOLTON FIELD OFFICE

AutoCAD SHX Text Installation of an Septic Aerobic Treatment Unit for SR#604 W Keller

AutoCAD SHX Text

OK 20-W24

AutoCAD SHX Text 5/8/2025

AutoCAD SHX Text

NTS

AutoCAD SHX Text Jim Shane

AutoCAD SHX Text Ted Schlueter

AutoCAD SHX Text Ted Schlueter

AutoCAD SHX Text

324 NEW YORK AVE., HOLTON, KS 66436 (785)364-4164

AutoCAD SHX Text 5/8/2025

AutoCAD SHX Text

JS

Sheets and Views
SR#604_OEH-8P_W Keller-Tank Details

File details come from the government source that posted it. Updated .