SR604_Bid Sheet_W Keller.pdf
PDF 100 KB Posted
- Attached to
- Aerobic Aeration System Highland, Kansas
- Solicitation number
- 246-25-Q-0074
About this file
This is a Request for Bid (RFB) from Holton OEH for a utility septic system installation project located at 1730 Diamond Springs Road in Highland, Kansas, for participant Wesley Keller (Service Request #604). The project scope includes furnishing and installing a 1,250-gallon two-compartment septic tank with 24" access risers, an effluent filter, an aerobic treatment unit with linear air pump and control unit, electrical supply and air supply piping, sanitary utility sewerage piping, cleanouts, septic tank abandonment, and restoration of disturbed construction areas. The project is associated with a related Indian Health Service solicitation (246-25-Q-0074) for an aerobic aeration system, which is a 100% Indian Owned set-aside under NAICS code 237110, with a performance period of 60 calendar days from the Notice to Proceed and an estimated award amount under $25,000.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ks4.txt | TXT text file | |
| SR604_OEH-8P_W Keller-Tank Details.pdf | ||
| SOW for ATU and Sewer Line Replacement.pdf | ||
| IHS IEE Representation Form_Jan 2022_508 Compliant.pdf | ||
| SR604_OEH-8P_W Keller-OEH-8P.pdf | ||
| RFQ246-25-Q-0074-SF18 and Clauses.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR BID
HOLTON OEH
PROJECT #:
OK 18-V24
EST.
QTY UNITS UNIT
PRICE TOTAL
1 LS
1 EA
1 LS
100 LF
10 LF
1 LS
30 LF
1 EA
1 LS
Total
All work shall be performed in accordance with contract specifications and drawings.
1730 Diamond Springs Road, Highland, Doniphan County, Kansas 66035
DESCRIPTION
UTILITY SEPTIC TANKS - Effluent Filter Furnish and install an effluent filter in place of outlet sanitary Tee.
UTILITY SEPTIC TANKS
Furnish and install 1,250 Gallon, two-compartment, Septic Tank with 24" access riser and lids over inlet and outlet sanitary tees, fittings and all appurtenances. Top of lids will be approximately 2" below finished grade.
Estimated quantities for services for the following applicant:
PARTICIPANT SR # LOCATION
SANITARY UTILITY SEWERAGE PIPING
Furnish and install 4" PVC Sch. 40 Solid Sewer Pipe, fittings and all appurtenances from house to septic tank and between septic tank and lagoon.
SANITARY UTILITY SEWERAGE CLEANOUTS
Furnish and install 4" schedule 40 PVC cleanouts as indicated on drawing.
UTILITY SEPTIC TANKS - Septic Tank Abandonment Abandon existing 500 gallon septic tank in place. Break bottom so to not hold water, backfill and compact to prevent settlement
AEROBIC TREATMENT UNIT -
Furnish an Install a lineal air pump, alarm/control unit, vented air pump enclusure. Pump and alarm/control unit to be on separate circuits.
AEROBIC TREATMENT UNIT - Electrical supply Furnish and install 12/3 wire with ground in conduit from pump to control panel an from pump to existing breaker panel on utility pole.
AEROBIC TREATMENT UNIT - Air Supply Piping Furnish and install 3/4" air supply pipe from linear pump to second compartment of septic tank.
TURF AND GRASSES
Fertilize, seed, and mulch all areas disturbed by construction activities.
SR#604 Wesley Keller 1730 Diamond Springs Road Highland, Kansas 66035 Page 1 of 2
REQUEST FOR BID
HOLTON OEH
Company Name:
I DO NOT WISH TO SUBMIT A BID ON THIS REQUEST
Initials
Authorized Signature: Date:
SR#604 Wesley Keller 1730 Diamond Springs Road Highland, Kansas 66035 Page 2 of 2
Aerobic Treatment Unit
File details come from the government source that posted it. Updated .