This document is a technical construction drawing and scope of work for an aerobic septic system installation by the Indian Health Service (IHS) in Highland, Doniphan County, Kansas. The project involves replacing an existing 500-gallon concrete septic tank with a new 1,250-gallon dual-compartment aerobic treatment unit (ATU) at a 4-bedroom home located at 1730 Diamond Springs Road. The scope of work includes abandoning the existing septic tank in place, installing 30 feet of 4" Schedule 40 PVC pipe, installing a 2-way cleanout, implementing an ATU with an air pump, vented rock pump enclosure, controls/alarm panel, electrical power supply, and air supply pipe, and installing an effluent filter and assembly. Additional components include 100 feet of 3/4" HDPE pipe buried at least 24 inches deep and an aerobic air pump with housing, with electrical supply available at a nearby power pole.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SS

L

SS

L

PROPOSE TO INSTALL

A 1,250 GALLON, DUAL

COMPARTMENT SEPTIC

TANK WITH AN EFFLUENT

FILTER AND FILTER ASSEMBLY.

RISER LIDS TO BE TERMINATED

APPROXIMATELY 2-INCHES BELOW

FINAL GRADE. AIR DIFFUSER IN

SECOND COMPARTMENT OF TANK.

4 BDRM

HOME

ABANDON IN PLACE

THE EXISTING

500 GALLON SEPTIC

TANK.

PROPOSED 2 -WAY

CLENOUT TO BE

INSTALLED

INSTALL 30FT OF 4"

SCHEDULE 40 PVC PIPE

GARAGE

SWIMMING POOL

WITH DECK

EXISTING 1-WAY

CLEANOUT

E

E E

E

CHAMBERED

DRAIN FIELDEXISTING 4" SCHEDULE 40

PVC SEWER LINE

APPROXIMATELY 3FT DEEP

1730 D

IAM

O N

D

SPR

IN

G

R O

AD

SCOPE OF WORK:

ABANDON EXISTING 500 GALLON CONCRETE

SEPTIC TANK IN PLACE.

INSTALL 30 FEET OF 4" SCHEDULE 40 PVC

PIPE.

INSTALL A 2-WAY CLEANOUT IN NEW 4"

PIPE.

INSTALL AN AEROBIC TREATMENT UNIT

(ATU), CONSISTING OF A 1,250 GALLON, DUAL

COMPARTMENT SEPTIC TANK, AIR PUMP,VENTED

REPLICA ROCK PUMP ENCLOSURE, CONTROLS /

ALARM PANEL, ELECTRICAL POWER SUPPLY AND

AIR SUPPLY PIPE FROM AEROBIC AIR PUMP TO

SECOND COMPARTMENT OF SEPTIC TANK.

INSTALL AN EFFLUENT FILTER AND

ASSEMBLY IN PLACE OF OUTLET BAFFLE.

1730 DIAMOND SPRINGS ROAD

HIGHLAND, DONIPHAN COUNTY, KANSAS

66035

LEGAL DESCRIPTION: SECTION 24, T02S,

R19E

LATITUDE: 39.86039305 N

LONGITUDE: -95.2452750 W

INSTALL 100FT OF 3/4 "

HDPE PIPE, BURIED AT

A MINIMUM OF 24" DEEP

INSTALL AN AEROBIC AIR

PUMP AND PUMP HOUSING.

ELECTRICAL SUPPLY IS AVAILABLE

AT POWER POLE. ELECTRICAL

WIRE SHALL BE IN CONDUIT.

PROPANE

TANK

IN

D

I A N

HEA LTH SER

V

ICE

1 9 5 5

NOT TO SCALE

AutoCAD SHX Text

INDIAN HEALTH SERVICE

AutoCAD SHX Text

OFFICE OF ENVIRONMENTAL

AutoCAD SHX Text

SANITATION FACILITIES CONSTRUCTION

AutoCAD SHX Text

HEALTH & ENGINEERING

AutoCAD SHX Text

LAYOUT NAME:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJ ENG:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

324 NEW YORK AVE, HOLTON, KS 66436 (785)364-4164

AutoCAD SHX Text Holton Field Office

AutoCAD SHX Text Installation of an Septic Aerobic Treatment Unit for SR#604 W Keller

AutoCAD SHX Text Project Number: OK 20-W24

AutoCAD SHX Text 5/8/2025

AutoCAD SHX Text

NTS

AutoCAD SHX Text Jim Shane

AutoCAD SHX Text Ted Schlueter

AutoCAD SHX Text Ted Schlueter

Sheets and Views
SR#604_OEH-8P_W Keller-OEH-8P