ATTACHMENT_VI-_QAPS.pdf

PDF 384 KB Posted

Attached to
FUEL MANAGEMENT SERVICES Federal contract opportunity
Solicitation number
SPE603-18-R-0519
Issued by
Defense Logistics Agency Energy

About this file

Attachment VI QAPS

View the file

Other files for this federal contract opportunity

Other files attached to FUEL MANAGEMENT SERVICES, newest first.
File Type Posted
SF30_SPE60318R05190003_signed.pdf PDF
SF30_SPE60318R0519000_signed.pdf PDF
SF30_SPE60318R05190006_signed.pdf PDF
SF30_SPE60318R05190005_signed.pdf PDF
SF30_SPE60318R05190004.pdf PDF
SF30_SPE60318R05190002_signed.pdf PDF
Solicitation_SPE603-18-R-0519_Sept_7,_2018.pdf PDF
SF30_SPE60318R05190005_signed.pdf PDF
SF30_SPE60318R05190004.pdf PDF
Revised_ATTACHMENT_V_CBA_COMBINED_Redacted.pdf PDF
ATTACHMENT_V_-_CBA_WAGE_DETERMINATION_HEADER_2017-2020_Amendment_0002.pdf PDF
SF1449_rev.pdf PDF
QUESTIONS_AND_ANSWERS_Final.pdf PDF
Appendix_G_CAC_Procedures.pdf PDF
ATTACHMENT_V_-_CBA_WAGE_DETERMINATION_HEADER_2017-2020.pdf PDF
Peterson_AFB_Appendix_AF_-_26_Apr_18.pdf PDF
Solicitation_SPE603-18-R-0519_June_11,_2018.pdf PDF
ATTACHMENT_IV_JOINT_VENTURE_CONSENT_FORM.pdf PDF
Buckley_AFB_Appendix_AF_-_26_Apr_18.pdf PDF
AF_Consolidated_PWS_-_as_of_12_Feb_18.pdf PDF
ATTACHMENT_III_-_PPQ.pdf PDF
SF1449_rev.pdf PDF
ATTACHMENT_II__rev2_-_OSP.pdf PDF
AF_Consolidated_PWS_-_as_of_9_Jun_17.pdf PDF
AF_Consolidated_PWS_-_Appendix_AF_template_-_Peterson_AFB_-_Apr_17_DRAFT.pdf PDF
AF_Consolidated_PWS_-_Appendix_AF_template_-_Buckley_AFB_-_Apr_17_DRAFT.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT VI – QUALITY ASSURANCE PROVISIONS

SPE603-18-R-0505

AF GOCO SOUTHWEST REGION LOCATIONS

ATTACHMENT VI –QUALITY ASSURANCE PROVISIONS

Table of Contents

QUALITY ASSURANCE PROVISIONS

E0001 E1.01 CONTRACTOR RESPONSIBILITY FOR GOVERNMENT INSPECTION OF SERVICES (DLA

ENERGY JAN 2012)

E-0002 E1.11-1 QUALITY CONTROL PLAN (DLA ENERGY APR 2007)

E-0003 E22 LIST OF INSPECTION OFFICES FOR DLA ENERGY CONTRACTS (DLA ENERGY APR 2016) .. 2

E-0004 E22.01 QUALITY REPRESENTATIVE

E-0005 E28 CONTRACTOR INSPECTION RESPONSIBILITIES(STORAGE) (DLA ENERGY DEC 2011)

E-0006 E35 NONCONFORMING SUPPLIES AND SERVICES (DLA ENERGY DEC 2011)

QUALITY ASSURANCE PROVISIONS

E0001 E1.01 CONTRACTOR RESPONSIBILITY FOR GOVERNMENT INSPECTION OF SERVICES

(DLA ENERGY JAN 2012)

If any inspection or test is made by the Government on the premises of the Contractor or subcontractor, the Contractor without additional charge shall provide all reasonable facilities and assistance for the safety and convenience of the Government inspectors in the performance of their duties.

E-0002 E1.11-1 QUALITY CONTROL PLAN (DLA ENERGY APR 2007)

(a) Upon award, the Contractor shall prepare, in triplicate and in English, a Quality Control Plan

(QCP). Prior to the first receipt of Government-owned product into the facility, two copies of the QCP shall be forwarded to the Contracting Officer and one copy to the assigned Quality Assurance

Representative for approval.

(b) The QCP shall include the following quality control procedures employed by the Contractor.

(1) Receiving (both product and additives);

(2) Blending;

(3) Storage and handling;

(4) Loading and Shipping;

(5) Calibration program for testing and measuring equipment in accordance with ISO 10012-1, "Quality Assurance Requirements for Measuring Equipment, Part I." Equivalent local regulation, as appropriate, may be used as well. Whichever program used must include a section addressing meter proving (used to determine quantity) and must comply with the American Petroleum Institute Manual of

Petroleum Measurement Standards, Chapters 4, 5, and 6, or equivalent foreign standard. For any item that requires calibration but is not covered by ASTM, API, or IP publications, the applicable

AF GOCO SOUTHWEST REGION LOCATIONS

manufacturer's recommended calibration method(s) outlined in the applicable industry publication shall be used if acceptable to the Government;

(6) Quantity measurement

(7) Records and report; and

(8) Corrective action procedures (to include, but not be limited to, procedures for notification of

Quality Representative, actions to be taken on discovery of off-spec product during receipts/shipments, upgrading procedures for Contractor-caused contamination, leaks, etc.). The QCP shall also include an organizational chart of key personnel and their responsibilities and a schematic diagram of the facility with key inspection/activity points marked for each product handled.

(c) The QCP shall require that each Contractor employee be familiar with its content and shall state that it must be reviewed semiannually and revised as needed. Revision should occur when any change is made to the inspection system, when any corrective action needs to be incorporated due to quality problems, and as otherwise necessary. The Contractor shall sign and date each revision of the QCP.

E-0003 E22 LIST OF INSPECTION OFFICES FOR DLA ENERGY CONTRACTS (DLA ENERGY

APR 2016)

The following lists shall be used to identify the Government inspection office assigned inspection responsibility for DLA Energy contracts in a particular geographic area. These contracts include, but are not limited to, those for bulk petroleum products and additives, into-plane refueling, petroleum storage and laboratory services, coal, aerospace energy (including compressed gases), and posts, camps, and stations.

The area of inspection responsibility and corresponding office code are assigned in paragraphs (a) and

(b). The address and phone number of each inspection office by office code is provided in paragraph (c).

Unless a particular inspection office is identified in another part of the contract, the assignments in this contract provision shall apply.

(a) AREAS OF RESPONSIBILITY AND OFFICE CODES WITHIN THE CONTINENTAL UNITED STATES

(CONUS):

Alabama 110 Maine 110 Oklahoma 110

Arizona 120 Maryland 110 Oregon 120

Arkansas 110 Massachusetts 110 Pennsylvania 110

California 120 Michigan 110 Rhode Island 110

Colorado 120 Minnesota 110 South Carolina 110

Connecticut 110 Mississippi 110 South Dakota 110

Delaware 110 Missouri 110 Tennessee 110

District of Columbia 110 Montana 120 Texas 110 1

Florida 110 Nebraska 110 Utah 120

AF GOCO SOUTHWEST REGION LOCATIONS

Georgia 110 Nevada 120 Vermont 110

Idaho 120 New Hampshire 110 Virginia 110

Illinois 110 New Jersey 110 Washington 120

Indiana 110 New Mexico 120 West Virginia 110

Iowa 110 New York 110 Wisconsin 110

Kansas 110 North Carolina 110 Wyoming 120 2

Kentucky 110 North Dakota 110

Louisiana 110 Ohio 110

EXCEPTIONS:

1 The El Paso, Texas area is assigned to Code 120 (DLA Energy Americas - West).

2 The Newcastle, Wyoming, area is assigned to Code 110 (DLA Energy Americas - East).

(b) AREAS OF RESPONSIBILITY AND OFFICE CODES OUTSIDE THE CONTINENTAL UNITED STATES

(OCONUS) (INCLUDING ALASKA AND HAWAII):

Afghanistan 400 Cyprus 200 Malaysia 300 Singapore 300 Africa 200 3 Egypt 400 3 Maldives 300 South America 110 Alaska 300 Europe (Continental) 200 Malta 200 South Korea 300 Antarctica 300 Georgia 300 Mauritius 200 Sri Lanka 300 Armenia 200 Greenland 200 Mexico 110 Syria 400 Ascension Island 110 Hawaiian Islands 300 Midway Island 300 Taiwan 300 Australia 300 Hong Kong 300 Mongolia 300 Tajikistan 400 Azerbaijan 200 Iceland 200 Myanmar 300 Thailand 300 Azores 200 India 300 Nepal 300 Turkey 200 Bahrain 400 Indonesia 300 New Zealand 300 Turkmenistan 400 Bangladesh 300 Ireland 200 North Korea 300 United Arab Bermuda 110 Iran 400 Oman 400 Emirates 400 Bhutan 300 Iraq 400 Pacific Islands United Kingdom 200 Brunei 300 Israel 200 (Central & South) 300 Uzbekistan 400 Cambodia 300 Japan 300 Pakistan 400 Vietnam 300 Canada 110/120 4 Jordan 400 Papua New Guinea 300 Wake Island 400 Canary Island 200 Kazakhstan 400 Philippines 300 Yemen 400 Caribbean Islands 110 Kuwait 400 Qatar 400 Central America 110 Kyrgyzstan 300 Russia 200 Chagos Archipelago 300 Laos 300 Ryukus Islands, Japan 300 China 300 Lebanon 400 Saudi Arabia 400 Comoros 200 Madagascar 200 Seychelles Is. 200

AF GOCO SOUTHWEST REGION LOCATIONS

EXCEPTIONS:

3 Except for Egypt, which is assigned to DLA Energy Middle East (Code 400), all other countries in Africa fall under DLA Energy Europe (Code 200).

4 The provinces of Manitoba, Ontario, Quebec, Newfoundland and Labrador, New Brunswick, Nova

Scotia, and Prince Edward Island are assigned to DLA Energy Americas East (Code 110). The rest of

Canada falls under DLA Energy Americas West

(c) INSPECTION OFFICES AND CODES.

110. DLA Energy Americas East ATTN: Quality Manager 5

Federal Building, Suite 1005 2320 LaBranch Street Houston, TX 77004-1091 Phone: (713) 750-9514/9561

FAX: (713) 750-0041

120. DLA Energy Americas West ATTN: Quality Manager 5 3171 N Gaffey Street San Pedro, CA 90731- I 099 Phone: (310) 241-2806/2807

FAX: (310)241-2836

200. DLA Energy Europe and Africa Military Mailing Address:

DLA Energy Petroleum Lab ATTN: Quality Manager 5 CMR 422

APO AE 09067-0422

Phone: 49-63 l-3406-2285/2286 6

FAX: 49-631-3406-2289 6

Commercial Shipping Address: DLA Energy Petroleum Lab ATTN: Quality Manager Bldg. 320, Rhine Ordinance Barracks Am Opelkreisel 67663 Kaiserslautem, Germany

300. DLA Energy Pacific ATTN: Quality Manager 5 1025 Quincy Avenue, Building 479, Suite 2000 Pearl Harbor, HI 96860-4512 Phone: (808) 473-4307/4287

FAX: (808) 473-4232

400. DLA Energy Middle East ATTN: Quality Manager 5 PSC 851, Box 180

FPO AP 09834-2800

Phone: 973-1785-6493 6

FAX: 973-1785-4650 6

[Location: Bahrain]

5 Designated location of the DLA Energy Regional Quality Manager/Pre-Award Survey Monitor.

AF GOCO SOUTHWEST REGION LOCATIONS

6 Dial 011 before these numbers when calling from the U.S. When calling these numbers from outside the U.S., use the appropriate international long distance prefix for the country where the call originates.

E-0004 E22.01 QUALITY REPRESENTATIVE

The Quality Office assigned inspection responsibility under this contract is

DLA Energy Americas West ATTN: Quality Manager 5 3171 N Gaffey Street San Pedro, CA 90731- I 099 Phone: (310) 241-2806/2807

FAX: (310)241-2836

E-0005 E28 CONTRACTOR INSPECTION RESPONSIBILITIES(STORAGE) (DLA ENERGY DEC

2011)

(a) Inspection and tests by the Government of services, facilities, and equipment specified within this contract does not relieve the Contractor from responsibility to meet all requirements of the contract.

(b) The Contractor shall furnish personnel, facilities, and equipment on-site to accomplish the following routine tests and procedures. These on-site resources may be provided by Contractor personnel or by a commercial source action on behalf of the Contractor. The Quality Representative will not be responsible for performing any of these services for the Contractor.

(1) Sampling of storage tanks, shipments and receipts in accordance with ASTM D 4057, Standard Practice for Manual Sampling of Petroleum and Petroleum Products (API Manual of Petroleum

Measurement Standards (MPMS), Chapter 8.1);

(2) Retaining of product composite samples from shipments and receipts as follows:

MINIMUM

METHOD OF SHIPMENT MINIMUM QUANTITY RETENTION PERIOD

Pipeline 20 liters 60 days Tanker/Barge Parcel Composite 20 liters 90 days Each compartment 0.5 liters 90 days Navy Fleet Oilers/Vessels 10 liters 60 days Tank Truck/Car 1 liter 15 days

NOTE: After the minimum retention period, samples shall be tested for Appearance, Color

(Visual), API Gravity/Density and Flash Point and, if found to be on-specification, shall be returned to like Government stock on-site. Sample containers may be reused if properly cleaned.

(3) Determining the presence of water in storage tanks, shipments and receipts. Ensure that accurate water cuts are obtained by means of a water indicating paste conforming to MIL-W-83779B. Two suggested sources are Stewart Hall Chemical Testmaster Water Indicating Paste or Sartomer Sar Gel Water

Indicating Paste (see Note 2 below);

(4) Determining Density at 15 degrees Celsius or API gravity of products by ASTM D 1298 or

ASTM D 4052 (see Note 2 below);

(5) Determining the temperature of products by the API MPMS, Chapter 7 (see Note 2 below);

(6) Determining the Appearance of applicable products using ASTM D 4176, Procedure 1 (see Note 2 below);

(7) Determining the visual color of products.

AF GOCO SOUTHWEST REGION LOCATIONS

(8) Determining the Flash Point of applicable products using test methods cited in the appropriate product specification

(see Note 2 below);

(9) Conversion of gross to net gallonage (liters);

(10) Determining the percentage (volume) of fuel system icing inhibitor (FSII) by means of a portable refractometer in accordance with ASTM D 5006. One suggested source is H.B. Industries, Inc., Glenview, IL 60025 (B/2 Anti-Icing Additive test kit) (see Note 2 below); and

(11) Determining the range of fuel electrical conductivity using ASTM D 2624. One suggested source for a conductivity meter is Emcee Electronics, Inc., Sarasota, FL 33581 (Model 1152) (see Note 2 below).

Note 1: All costs for providing the above tests and procedures shall be included in the monthly service charge. The only exception to the Contractor’s obligation to provide these services as part of the monthly service charge is when the tests described above are part of the higher order analysis (defined as the following categories: Composite Samples, Storage Tanks After Receipt, Interface Mixtures, Dormant Stocks and Individual Tests (including particulate contamination) found in the attachment to the solicitations entitled MINIMUM REQUIREMENTS FOR STORAGE SAMPLING AND TESTING. Provisions for providing higher order analyses are covered in the SAMPLING AND TESTING OF PETROLEUM

PRODUCTS (STORAGE) contract provision.

Note 2: Upon request, the Contractor shall permit the Quality Representative unrestricted use of the equipment and ancillary supplies needed to perform this test/procedure on behalf of the Government.

(c) During the contract, the Contractor shall furnish representative samples of the product in each storage tank, shipment or receipt at the request of, and in the manner and to the place designated by, the Quality Representative. Sample size will be 2 gallons for gasoline- type fuels and one gallon or 10 gallons for jet diesel-type fuels. The number of samples to be furnished during any 12-month period shall not exceed eight times the number of tanks specified in the contract. Such samples shall be packed, marked, and shipped by the Contractor, shipping expense prepaid, in containers and shipping boxes furnished by the Contractor. Sample containers shall be epoxy coated on the interior. This requirement is in addition to sampling required elsewhere in this contract provision and the contract. All reasonable direct shipping costs associated with samples required by this paragraph shall be reimbursed upon request from the Contractor and such costs shall not be included in the monthly service charge. However, all other costs related to this requirement shall be included as part of the monthly service charge.

E-0006 E35 NONCONFORMING SUPPLIES AND SERVICES (DLA ENERGY DEC 2011)

(a) DEFINITION: As used in this contract provision:

Deviation is defined as a written authorization granted after contract award and prior to manufacture of an item, to depart from a particular performance or design requirement of a contract, specification, or referenced document, for a specific number of units or specific period of time, normally the duration of the contract.

Extraordinary situation means the matter cannot await resolution until the next DLA Energy business day (0800 to 1630 hours EST, Monday through Friday, Federal Holidays excluded).

Waiver is defined as a written authorization granted after contract award to accept a configuration item or other designated item which, during production or after having been submitted for inspection, is found to depart from specified requirements, but nevertheless is considered suitable for use “as is” or after repair by an approved method. Approval is on a case-by-case basis and is normally for a set period of time.

(b) The Government may, at its discretion, accept nonconforming supplies or services. In such cases, the Contractor must obtain a deviation or waiver from the Contracting Officer prior to acceptance.

(c) The following procedures shall be used to request a deviation or waiver.

AF GOCO SOUTHWEST REGION LOCATIONS

(1) Requests for deviations and waivers shall be submitted by the Contractor to the Contracting

Officer with a copy to the appropriate Inspection Office referenced in the LIST OF INSPECTION OFFICES

FOR DLA ENERGY CONTRACTS or QUALITY REPRESENTATIVE Contract provision of this contract. Each request shall provide the following information: Contractor name; name and contact information of the contractor’s authorized negotiator; contract number; contract line item number and product nomenclature, clause or contract provision number, paragraph and subparagraph, as appropriate; the nature of the request; the reason for the request; the corrective action being taken by the Contractor to correct and prevent recurrence of the condition(s) causing the nonconformance; and an agreement to pay an equitable price reduction, estimated and proposed by DLA Energy, over and above the administrative fee, contingent on the impact of the specific circumstances on DLA Energy relative to approval of the deviation or waiver.

(2) In extraordinary situations, the Contractor may initially submit a verbal request for a waiver, but not a deviation, to the Contracting Officer. Written requests shall be submitted to the Contracting

Officer by the next DLA Energy business day (0800 to 1630 hours EST, Monday through Friday, Federal

Holidays excluded). If the Contracting Officer cannot be reached, the Duty Officer shall be contacted to provide the necessary information to the proper individuals as soon as possible. The Duty Officer's telephone number is (800) 286-7633 or (703) 767-8420.

(3) If a deviation or waiver is granted, the contract will be modified to accept the nonconforming supplies or services and to require the Contractor to provide an equitable price reduction or other adequate consideration commensurate with the deviation or waiver being granted. If the situation warrants, a deviation or waiver may be granted without prior agreement on price reduction or other consideration, subject to agreement by the Contractor, or its representative, to subsequent negotiation.

Such an agreement, in addition to a brief description of the terms of the deviation or waiver, shall be documented on the shipping document or other appropriate correspondence. After negotiations, failure to agree on adequate consideration shall be a dispute concerning a question of fact within the meaning of the Disputes paragraph of the CONTRACT TERMS AND CONDITIONS – COMMERCIAL ITEMS contract provision of this contract.

(4) If a deviation or waiver is granted and the nonconforming supplies are accepted, then in no event will consideration be less than $500, which covers administrative costs, plus any additional cost of

Government re-inspection or retest, if necessary.

(5) If a deviation or waiver is granted modifying this contract, but the supplies accepted are subsequently determined to be in conformity with contract specifications, the Contractor shall still be obligated to pay the consideration originally agreed upon in support of the deviation or waiver. If, however, this consideration exceeds $1000, a second contract modification shall be issued reducing the

Contractor's obligation to $1000 (the administrative cost of issuing the two required modifications), plus, if appropriate, any cost of Government re-inspection or retest performed as a result of the deviation or waiver being granted.

(d) When notification of nonconforming supplies is received after the supplies have been accepted, and the Government determines not to exercise its right to reject or to require correction under the

INSPECTION OF SUPPLIES – FIXED-PRICE, INSPECTION OF SERVICES – FIXED PRICE, or CONTRACT TERMS

AF GOCO SOUTHWEST REGION LOCATIONS

AND CONDITIONS – COMMERCIAL ITEMS contract provision, then in no event will consideration be less than $500 to cover administrative costs. This $500 fee is in addition to—

(1) Consideration commensurate with the extent of nonconforming supplies; and

(2) Cost of Government re-inspection or retest, if necessary.

The administrative fee will apply to each claim letter issued for off-specification product delivered to an activity.

(e) Contractors shall be held responsible for payment of any fines or penalties imposed on a receiving activity by an environmental enforcement agency, resulting from the delivery of nonconforming supplies under a DLA Energy contract.

(f) Repeated tender of nonconforming supplies or services, including those with only minor defects, will be discouraged by appropriate actions, including, but not limited to, rejecting the supplies or services whenever feasible and documenting the Contractor's performance records.

File details come from the government source that posted it.